HomeMy WebLinkAboutCarmel ESS - 100%_BID AND PERMIT SET incl. BID ADD. #1-5PROJECT LOCATION
155 CARMEL DRIVE
CARMEL, IN 46032
PROJECT LOCATION
155 CARMEL DRIVE
CARMEL. IN 46032 DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
G001
COVER SHEET
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff -Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
BUILDING INFORMATIONPROJECT CONTACTS DESIGN TEAM CONTACTS
SITE LOCATION
ARCHITECT
PH 317 264-8162
Indianapolis, Indiana 46202
618 East Market Street
Axis Architecture + Interiors
DRAWING INDEX
BUILDING LOCATION
CLIENT
CARMEL
Extra Space Storage
155 CARMEL DRIVE, CARMEL, IN
Weihe Engineers
10505 N. College Avenue
Brad Schoeff -Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
AUGUST 27, 2020 - 100% BID & PERMIT SET
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
DREW WHITE, Partner in Charge
GEOFF DESMIT, Project Manager
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
First Floor
CONSTRUCTION TYPE
USE GROUP
BUILDING GROSS AREA
Second Floor
Third Floor
B, S-2
II-B
GROSS AREA TOTAL AUGUST 17TH, 2020 - 100% PERMIT DOCUMENTS SETAUGUST 27TH, 2020 - 100% BID & PERMIT SET............DWG # DRAWING NAME
● ● A700 FINISH SCHEDULES AND SPECIFICATIONS
MECHANICAL
● ● M001 HVAC SYMBOLS, NOTES, ABBREVEATIONS
● ● M002 HVAC DETAILS AND SCHEDULES
● ● M100 FIRST FLOOR HVAC PLAN
● ● M200 SECOND FLOOR HVAC PLAN
● ● M300 THIRD FLOOR HVAC PLAN
● ● M400 ROOF HVAC PLAN AREA
PLUMBING
● ● P001 PLUMBING ABBREVIATIONS, SYMBOLS & SPECIFICATIONS
● ● P002 PLUMBING DETAILS AND SCHEDULES
● ● P100 FIRST FLOOR WASTE PLAN
● ● P101 FIRST FLOOR WATER PLAN
● ● P200 SECOND FLOOR PLUMBING
● ● P300 THIRD FLOOR PLUMBING
● ● P400 ROOF TOP PLUMBING PLAN
ELECTRICAL
● ● E001 ELECTRICAL ABBREVIATIONS, SYMBOLS & SPECIFICATIONS
● ● E002 ELECTRICAL DETAILS & RISER DIAGRAM
● ● E003 ELECTRICAL SCHEDULES AND ENLARGED OFFICE
● E050 ELECTRICAL SITE PLAN
● ● E100 FIRST FLOOR ELECTRICAL PLAN
● ● E200 SECOND FLOOR ELECTRICAL PLAN
● ● E300 THIRD FLOOR ELECTRICAL PLAN
● ● E400 ELECTRICAL ROOF PLANAUGUST 17TH, 2020 - 100% PERMIT DOCUMENTS SETAUGUST 27TH, 2020 - 100% BID & PERMIT SET............DWG # DRAWING NAME
GENERAL
● ● G001 COVER SHEET
● ● G002 CODE REVIEW
● ● G003 FIRST FLOOR LIFE SAFETY PLAN
● ● G004 SECOND FLOOR LIFE SAFETY PLAN
● ● G005 THIRD FLOOR LIFE SAFETY PLAN
CIVIL
● ● C001 TITLE SHEET
● ● C100 EXISTING CONDITIONS
● ● C101 EXISTING CONDITIONS
● ● C102 STORMWATER POLLUTION PREVENTION PLAN PHASE I
● ● C103 STORMWATER POLLUTION PREVENTION PLAN PHASE II
● ● C104 STORMWATER POLLUTION PREVENTION PLAN SPECS
● ● C105 STORMWATER POLLUTION PREVENTION PLAN DETAILS
● ● C106 STORMWATER POLLUTION PREVENTION PLAN DETAILS
● ● C200 SITE PLAN
● ● C201 SITE PLAN DETAILS
● ● C300 GRADING PLAN
● ● C600 DRAINAGE PLAN
● ● C601 DRAINAGE DETAILS
● ● C602 DRAINAGE DETAILS
● ● C603 OVERLFOW ROUTING PLAN
● ● C604 OVERFLOW ROUTING PLAN
● ● C800 UTILITY PLAN
● ● C801 UTILITY PLAN DETAILS
● ● C900 SPECIFICATIONS
● ● C901 SPECIFICATIONS
● ● C902 SPECIFICATIONS
LANDSCAPE
● ● L100 LANDSCAPE PLAN
● ● L200 LANDSCAPE PLAN DETAILS
STRUCTURAL
● ● S001 GENERAL STRUCTURAL NOTES
● ● S101 FOUNDATION PLAN
● ● S102 SECOND FLOOR FRAMING PLAN
● ● S103 THIRD FLOOR FRAMING PLAN
● ● S104 ROOF FRAMING PLAN
● ● S201 SECTIONS AND DETAILS
● S202 SECTIONS AND DETAILS
● S203 SECTIONS AND DETAILS
ARCHITECTURAL
● ● A001 GENERAL NOTES, SYMBOLS, LEGENDS AND EXTERIOR WALLS
● ● A002 INTERIOR WALL TYPES AND DETAILS
● ● A003 ADA DETAILS
● ● A101 FIRST FLOOR CONSTRUCTION PLAN
● ● A102 SECOND FLOOR CONSTRUCTION PLAN
● ● A103 THIRD FLOOR CONSTRUCTION PLAN
● ● A104 ROOF PLAN
● ● A110 ENLARGED PLANS
● ● A120 STAIR PLANS AND SECTIONS
● ● A121 STAIR PLANS AND SECTIONS
● ● A122 STAIR DETAILS
● ● A201 EXTERIOR ELEVATIONS
● ● A202 EXTERIOR ELEVATIONS
● ● A204 3D EXTERIOR VIEWS
● ● A301 BUILDING SECTIONS
● ● A302 BUILDING SECTIONS
● ● A303 WALL SECTIONS
● ● A304 WALL SECTIONS
● ● A305 WALL SECTIONS
● ● A306 WALL SECTIONS
● ● A307 WALL SECTIONS
● ● A310 SECTION DETAILS
● ● A311 SECTION DETAILS
● A401 SOFFIT REFLECTED CEILING PLAN
● ● A501 DOOR SCHEDULE
● ● A502 EXTERIOR DOOR AND STOREFRONT DETAILS
● ● A503 WINDOW AND STOREFRONT ELEVATIONS
● ● A601 INTERIOR ELEVATIONS
● ● A610 MILLWORK SECTIONS
18,309 SQ. FT.
21,177 SQ. FT.
21,177 SQ. FT.
60,663 SQ. FT.
#DESCRIPTION DATE
07/14/21
APPLICABLE CODES
CONSTRUCTION TYPE
OCCUPANCY CLASSIFICATION
ALLOWABLE AREA
FIRE PROTECTIONS SYSTEMS
SCOPE OF PROJECT
INCIDENTAL USE SEPARATIONS
EGRESS CORRIDORS
PANIC HARDWARE
Type II-B - Permitted based upon allowable area and height for S-2, B
occupancy.
Tabular Area: 60,663 SQ. FT.
3 Stories
Actual Area Per Floor:
First Floor: 18,309 sf
Second Floor: 21,117 sf
Third Floor: 21,117 sf
Total: 60,663 sf
Sprinklers Provide per NFPA 13
Portable fire extinguishers Required per Carmel Indiana Local Code
Smoke detection Recommend interconnected smoke alarms in
sleeping areas as a minimum
Standpipes Are not required based upon the elevation of the 2nd
floor level at less than 30 feet above grade (905.3.1)
Fire Alarm System Not required based upon a calculated occupant
load of over 100 above or below the level or
discharge. (907.2.2)
Smoke Detectors Are required for HVAC shutdown for systems
delivering in excess of 2000 CFM, and for elevator
recall. (3003.2, 606.1 IMC)
Exit signs Required (Sec. 1011. 1)
Exit illumination Required (Sec. 1 006)
with emergency power
New three story personal storage facility.
Incidental use areas are required to be provided with smoke tight
construction. Partitions shall extend from the floor to the underside of
the floor, roof deck above, or tight ceiling. Doors shall be self-closing or
automatic-closing upon detection of smoke. Air-transfer openings shall
be provided with smoke dampers. Duct work does not need to be
dampered.
(509.4.2)
The following areas are considered incidental use areas:
(IBC Table 509).
Boiler and fuel equipment rooms over 400,000 BTU's/hour input.
Laundry rooms over 100 sq. ft.
Egress corridors are not require to be fire rated based upon automatic sprinkler
protection. (1018.1)
Required in an S occupancy. (1008.1.10)
Indiana General Administrative Rules
2014 Indiana Building Code (2012 International Building Code with Indiana
Amendments)
2014 Indiana Fire Code (2012 International Fire Code with Indiana Amendments)
2012 Indiana Plumbing Code (2006 International Plumbing Code with Indiana
Amendments)
2008 National Electrical Code (2008 NFPA 70)
2014 Indiana Mechanical Code (2012 International Mechanical Code with
Indiana
Amendments)
2010 Indiana Energy Code (ASHRAE 90.1 2007)
Americans with Disabilities Act Accessible Guidelines (ADAAG) for Buildings and
Facilities
American National Standards Institute Accessible and Usable Buildings and
Facilities Standard (CABO/ANSI A117.1-2009)
B, S-2 Occupancy (304.1)
EGRESS TRAVEL DISTANCE
Table 1016. 1, IBC limits the maximum travel distance in a sprinklered B occupancy
to 300 feet.
NUMBER OF EXITS
2 means of egress are required from rooms or areas with an occupant load
exceeding 50 or a common path of travel exceeding 100 feet. (1015.1)
# Exits
First Floor 2
Second Floor 2
Third Floor 2
OTHER SEPARATION
Electrical "Rooms"
Electrical vaults > 600 volts 3 hour rating [IEC, Sec. 110. 31 (A)]
Transformers
Dry type< 112-1/2 kVA Not required [IEC 450.21. (A)]
> 112-1/2 kVA 1 hour [IEC 4502. 1 (B)];
See exception
Vaults See section IEC 450.41 for exceptions
Switch gear-unenclosed In a vault following IEC 450.41
Switch gear over 35,000 volts through 450.48; See IEC 230.212
OCCUPANT LOAD AND EGRESS CAPACITY
See Occupancy Schedule this sheet for building occupant load
Total egress capacity provided exceed occupant load. Refer to plans this sheet.
DOOR SWING
Doors serving an area required to have two (2) or more exits shall swing in the
direction of egress travel (IBC, Sec. 1 008.1.2).
EXITING
Doors serving an area required to have two (2) or more exits shall swing in the
direction of egress travel (IBC, Sec. 1 008.1.2).
CODE SUMMARY
INDICATES ONE-HOUR RATED
CONSTRUCTION
INDICATES TWO-HOUR RATED
CONSTRUCTION
INDICATES EGRESS PATH
INDICATES FIRE EXTINGUISHER
LOCATIONFEC
EGRESS CAPACITY TAG
OCCUPANT LOAD
OCCUPANT CAPACITY
B 32
24000 SF
OCCUPANCY TAGNUMBER OF OCCUPANTS
SPACE FUNCTION FROM TABLE
1004.1.1
AREA OF SPACE
(net or gross)
B = Business/Office
S = Storage
M = Mechanical
A = Assembly
LIFE SAFETY PLAN LEGEND DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
G002
CODE REVIEW
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
# DESCRIPTION DATE
07/14/21
UP
100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10197 SF10 x 2024 SF5 x 549 SF10 x 5147 SF10 x 15147 SF10 x 15145 SF10 x 1573 SF10 x 7.573 SF10 x 7.573 SF10 x 7.572 SF10 x 7.536 SF5 x 7.524 SF5 x 549 SF10 x 549 SF10 x 599 SF10 x 1099 SF10 x 1049 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 5153 SF10 x 15 153 SF10 x 15151 SF10 x 15253 SF10 x 2549 SF10 x 549 SF10 x 599 SF10 x 1024 SF5 x 5147 SF10 x 1573 SF10 x 7.573 SF10 x 7.573 SF10 x 7.549 SF10 x 549 SF10 x 5100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1049 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 599 SF10 x 1099 SF10 x 10252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25153 SF10 x 15 153 SF10 x 15252 SF10 x 25151 SF10 x 15249 SF10 x 25253 SF10 x 25157 SF10 x 1598 SF10 x 1049 SF10 x 549 SF10 x 549 SF10 x 599 SF10 x 1099 SF10 x 1049 SF10 x 524 SF5 x 549 SF10 x 566
226
36" WIDE DOOR
(34" USABLE)
FEC
FEC
FEC
40
226
36" WIDE DOOR
(34" USABLE)
38
226
72" WIDE DOOR
(34" USABLE)
66
226
36" WIDE DOOR
(34" USABLE)
66
226
36" WIDE DOOR
(34" USABLE)
ADA RESTROOM
2 HOUR RATED
STAIRWELL
2 HOUR RATED
ELEVATOR
HOISTWAY
COMMON PATH OF TRAVEL = 125' -0"
COMMON PATH OF TRAVEL = 100' -0"
38
226
36" WIDE DOOR
(34" USABLE)
FEC
40
226
36" WIDE DOOR
(34" USABLE)
40
226
36" WIDE DOOR
(34" USABLE) 2 HOUR RATED
STAIRWELL
COMMON PATH OF TRAVEL = 120' -0"
COMMON PATH OF TRAVEL = 78' -0"DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
GSD
08.17.2020
G003
FIRST FLOOR LIFE SAFETY
PLAN
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff -Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
SCALE: 1/8" = 1'-0"02FIRST FLOOR LIFE SAFETY PLAN AREA A
SCALE: 1/8" = 1'-0" 01FIRST FLOOR LIFE SAFETY PLAN AREA B
#DESCRIPTION DATE
07/14/21
DN 102 SF10 x 10102 SF10 x 1099 SF10 x 10150 SF10 x 15100 SF10 x 10100 SF10 x 10100 SF10 x 10154 SF10 x 15F0102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10187 SF10 x 18.599 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF 10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 100 99 SF10 x 1049 SF10 x 5134 SF10 x 13.5147 SF10 x 15145 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15148 SF10 x 15148 SF10 x 1549 SF10 x 549 SF10 x 549 SF10 x 599 SF10 x 1099 SF10 x 100 F0199 SF10 x 20199 SF10 x 2049 SF10 x 549 SF10 x 525 SF5 x 599 SF10 x 1099 SF10 x 1099 SF10 x 10102 SF10 x 10102 SF10 x 10149 SF10 x 15149 SF10 x 15134 SF10 x 13.5149 SF10 x 1549 SF10 x 599 SF10 x 10199 SF10 x 20104 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 1050 SF10 x 599 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10199 SF10 x 20199 SF10 x 20199 SF10 x 2099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10199 SF10 x 20199 SF10 x 20199 SF10 x 20199 SF10 x 20199 SF10 x 20199 SF10 x 20199 SF10 x 20199 SF10 x 2099 SF10 x 1099 SF10 x 10199 SF10 x 2049 SF10 x 599 SF10 x 10199 SF10 x 2049 SF10 x 5156 SF10 x 1524 SF5 x 599 SF10 x 1049 SF10 x 549 SF10 x 524 SF5 x 566
226
36" WIDE DOOR
(34" USABLE)
FEC
FEC
COMMON PATH OF TRAVEL = 204' -0"COMMON PATH OF TRAVEL = 169' -0"66
226
36" WIDE DOOR
(34" USABLE)
COMMON PATH OF TRAVEL = 135' -0"
COMMON PATH OF TRAVEL = 140' -0"
FEC
2 HOUR RATED
STAIRWELL
DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
GSD
08.17.2020
G004
SECOND FLOOR LIFE
SAFETY PLAN
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff -Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
SCALE: 1/8" = 1'-0"02SECOND FLOOR LIFE SAFETY PLAN AREA A
SCALE: 1/8" = 1'-0" 01SECOND FLOOR LIFE SAFETY PLAN AREA B
#DESCRIPTION DATE
07/14/21
102 SF10 x 10102 SF 10 x 1099 SF10 x 10150 SF7.5 x 12.599 SF10 x 1099 SF10 x 1099 SF10 x 10153 SF7.5 x 12.549 SF10 x 599 SF10 x 10F099 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10103 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF 10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10F099 SF10 x 10148 SF10 x 13.5139 SF10 x 13.5134 SF10 x 13.5141 SF10 x 13.5147 SF10 x 15145 SF10 x 15149 SF10 x 15149 SF10 x 15F5F5149 SF10 x 15149 SF10 x 1549 SF10 x 549 SF 10 x 549 SF10 x 598 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1049 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 5149 SF10 x 15149 SF10 x 1599 SF10 x 1020 SF5 x 320 SF5 x 3102 SF10 x 10102 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10102 SF10 x 1099 SF10 x 1049 SF10 x 549 SF10 x 549 SF10 x 5DN 99 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 1599 SF10 x 1099 SF10 x 1099 SF10 x 10149 SF10 x 15150 SF10 x 1591 SF10 x 10149 SF10 x 15154 SF10 x 15149 SF10 x 15149 SF10 x 1549 SF10 x 549 SF10 x 549 SF10 x 5149 SF10 x 15149 SF10 x 1599 SF10 x 1086 SF
ELEV.
302
183 SF
STAIR
301
21' - 0 3/4" 9' - 5 3/8"
66
226
36" WIDE DOOR
(34" USABLE)
FEC
FEC
COMMON PATH OF TRAVEL = 204' - 0"COMMON PATH OF TRAVEL = 169' - 0"
2 HOUR RATED
STAIRWELL
2 HOUR RATED
ELEVATOR
HOISTWAY
66
226
36" WIDE DOOR
(34" USABLE)
COMMON PATH OF TRAVEL = 140' - 0"
FEC
2 HOUR RATED
STAIRWELL
DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
Author
GSD
08.17.2020
G005
THIRD FLOOR LIFE SAFETY
PLAN
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
SCALE: 1/8" = 1'-0"02THIRD FLOOR LIFE SAFETY PLAN AREA A
SCALE: 1/8" = 1'-0" 01THIRD FLOOR LIFE SAFETY PLAN AREA B
#DESCRIPTION DATE
07/14/21
116th ST.
CONSTRUCTION PLANS FOR
EXTRA SPACE STORAGE - CARMEL
147 & 155 WEST CARMEL DRIVE
CARMEL, IN 46032
DOCKET #PZ20010015-17 DP ADLS UV V
C001TITLE SHEETW190582-C001 titleNO SCALE
HAMILTON COUNTY
PROJECT LOCATION PROJECT LOCATION
LOCATION MAPAREA MAP
PROJECT BM
HARRISON MONUMENT AT THE EAST QUARTER CORNER OF SECTION 36, TOWNSHIP18
NORTH, RANGE 03 EAST PER HAMILTON COUNTY SURVEYOR'S OFFICE CORNER
NUMBER 18033606. LOCATED IN THE SOUTHBOUND LANE OF RANGELINE ROAD
APPROXIMATELY 190 FEET NORTH OF THE INTERSECTION OF EXECUTIVE DRIVE AND
RANGELINE ROAD.
ELEV.844.55 (NAVD 88)
SITE TBM
CUT 'X' ON THE SOUTH BONNET BOLT OF A FIRE HYDRANT LOCATED APPROXIMATELY 22
FEET NORTHWEST OF THE NORTHWEST CORNER OF THE SURVEYED REAL ESTATE ON
THE SOUTH SIDE OF CARMEL DRIVE.
ELEV.831.54 (NAVD 88)
BENCHMARK INFORMATION
APPROXIMATELY 4.3 ACRES LOCATED AT 147 AND 155 WEST CARMEL DRIVE - PART
OF SOUTHEAST 14, SECTION 36, TOWNSHIP 18 NORTH, RANGE 3 EAST, CLAY
TOWNSHIP, HAMILTON COUNTY, INDIANA
LAND DESCRIPTION
PLANS PREPARED FOR
ADAM FRENCH PROPERTY, LLC
9000 KEYSTONE CROSSING, SUITE 660
INDIANAPOLIS, IN 46240
TELEPHONE: (317) 733-6400
CONTACT PERSON: JIM ADAMS
EMAIL: JADAMS@FILCOLTD.COM
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING, OR VERIFYING THAT ALL PERMITS AND
APPROVALS ARE OBTAINED FROM THE RESPECTIVE CITY, COUNTY, AND STATE AGENCIES PRIOR TO
STARTING CONSTRUCTION.
2. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO DETERMINE THE EXACT LOCATION OF ALL
EXISTING UTILITIES IN THE VICINITY OF THE CONSTRUCTION AREA PRIOR TO STARTING
CONSTRUCTION
3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO NOTIFY AND COORDINATE CONSTRUCTION WITH
ALL RESPECTIVE UTILITIES.
4. ALL QUANTITIES GIVEN ON THESE PRINTS, VERBALLY OR IN THE SCOPE OF WORK SECTION ARE
ESTIMATES AND SHALL BE CONFIRMED BY THE BIDDING CONTRACTORS.
5. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL
RULE 29 CFR PART 1926, SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN
DEPTH.
6. IN ADDITION, EXCAVATION EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRE THE DESIGN OF A
TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER.
7. IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER AND CONTRACTOR TO MAINTAIN QUALITY
CONTROL THROUGHOUT THIS PROJECT.
8. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL
STANDARDS.
9. THE ENGINEER AND/OR OWNER DISCLAIM ANY ROLE IN THE CONSTRUCTION MEANS AND METHODS
ASSOCIATED WITH THE PROJECT AS SET FORTH IN THESE PLANS.
10. ANY FIELD TILES ENCOUNTERED DURING EXCAVATION SHALL BE REPAIRED AND CONNECTED TO NEW
STORM SEWERS AND POSITIVE DRAINAGE PRESERVED.
11. IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER THAT ALL LANDSCAPE REQUIREMENTS ARE MET
AND CONFORM TO APPLICABLE LOCAL STANDARDS.
12. THE SITE DOES NOT LIE IN A SPECIAL FLOOD HAZARD AREA AS ESTABLISHED BY THE FEDERAL
EMERGENCY MANAGEMENT AGENCY - NATIONAL FLOOD INSURANCE PROGRAM, WHEN PLOTTED BY
SCALE ON FLOOD INSURANCE RATE MAP #18057C0209 G, DATED NOVEMBER 19, 2014.
13. BEARINGS, DIMENSIONS AND EASEMENTS ARE SHOWN FOR REFERENCE ONLY. SEE RECORD
SURVEYS & PLAT FOR EXACT INFORMATION.
14. THIS SITE DOES NOT CONTAIN ANY WETLANDS AT SHOWN ON THE U.S. DEPARTMENT OF THE INTERIOR
FISH AND WILDLIFE SERVICE; NATIONAL WETLANDS INVENTORY MAP.
GENERAL NOTES
W
S
N
E
CITY OF CARMEL PLANNING
ONE CIVIC SQUARE
CARMEL, IN 46032
ANGIE CONN / ALEXIA LOPEZ
TEL: 317/571-2417
CITY OF CARMEL ENGINEERING
ONE CIVIC SQUARE
CARMEL, IN 46032
JOHN THOMAS / ALEX JORDAN
TEL: 317/571-2441
CITY OF CARMEL BLDG SERVICES
ONE CIVIC SQUARE
CARMEL, IN 46032
JIM BLANCHARD
TEL: 317/571-2444
CITY OF CARMEL FIRE DEPARTMENT
TWO CIVIC SQUARE
CARMEL, INDIANA 46032
CHRIS ELLISON
TEL: 317/571-2600
CARMEL CITY UTILITIES
30 W MAIN ST, SUITE 220
CARMEL, INDIANA 46032
JOHN DUFFY
TEL: 317/571-2648
HAMILTON COUNTY SURVEYOR
ONE HAMILTON COUNTY SQUARE
SUITE 188
NOBLESVILLE, INDIANA 46060
TEL: 317/776-8495
HAMILTON COUNTY HIGHWAY DEPT
1700 SOUTH 10TH STREET
NOBLESVILLE, INDIANA 46060
TEL: 317/773-7770
HAMILTON COUNTY HEALTH DEPARTMENT
18030 FOUNDATION DR. SUITE A
NOBLESVILLE, INDIANA 46060
JASON LEMASTER
TEL: 317/776-8500
CLAY TOWNSHIP REGIONAL WASTE DISTRICT
10701 NORTH COLLEGE AVENUE, SUITE A
INDIANAPOLIS, IN 46280-1098
RYAN HARTMAN
TEL: 317/844-9200
DUKE ENERGY
100 SOUTH MILL CREEK RD.
NOBLESVILLE, INDIANA 46060
TEL: 317/776-5352
COMCAST
9750 E. 150th STREET
SUITE 1600
NOBLESVILLE, INDIANA 46060
TEL: 317/776-4495
VECTREN GAS
P.O. BOX 1700
NOBLESVILLE, INDIANA, 46060
TEL: 317/776-5573
AT&T
5858 NORTH COLLEGE
INDIANAPOLIS, INDIANA 46220
TEL: 317/252-5168
OPERATING AUTHORITIES
PLANS PREPARED BY
WEIHE ENGINEERS, INC.
10505 N. COLLEGE AVE.
INDIANAPOLIS, INDIANA 46280
TELEPHONE: (317) 846-6611
FAX: (317) 843-0546
CONTACT PERSON: BRAD SCHOEFF
EMAIL: SCHOEFFB@WEIHE.NET
REVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, Indiana W19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
EXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJSENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
CARMEL DR.
CITY CENTER DR.
MAIN ST.RANGELINE RD. RANGELINE RD.GUILFORD RD.MAIN ST.
116th ST.
CITY CENTER DR.PENNSYLVANIA ST.US 31US 31
OLD MERIDIAN ST.KEYSTONE AVE.KEYSTONE AVE.CARMEL DR.
116th ST.116th ST.
CARMEL DR.RANGELINE RD. RANGELINE RD.SHEET INDEX
Sheet Number Sheet Title
C001 TITLE SHEET
1 & 2 ALTA NSPS LAND TITLE SURVEY
C100 EXISTING CONDITIONS
C101 EXISTING CONDITIONS
C102 STORMWATER POLLUTION PREVENTION PLAN PHASE I
C103 STORMWATER POLLUTION PREVENTION PLAN PHASE II
C104 STORMWATER POLLUTION PREVENTION PLAN SPECS
C105 STORMWATER POLLUTION PREVENTION PLAN DETAILS
C106 STORMWATER POLLUTION PREVENTION PLAN DETAILS
C200 SITE PLAN
C201 SITE PLAN DETAILS
C300 GRADING PLAN
C600 DRAINAGE PLAN
C601 DRAINAGE DETAILS
C602 DRAINAGE DETAILS
C603 OVERFLOW ROUTING PLAN
C604 OVERFLOW ROUTING PLAN
C800 UTILITY PLAN
C801 UTILITY PLAN DETAILS
C900 SPECIFICATIONS
C901 SPECIFICATIONS
C902 SPECIFICATIONS
L100 LANDSCAPE PLAN
L200 LANDSCAPE PLAN DETAILS
CITY OF CARMEL STANDARD NOTES
1. NO EARTH DISTURBING ACTIVITY MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT
PERMIT
2. THESE PLANS COMPLY WITH ALL ADA REQUIREMENTS.
3. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER.
UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED
DEVELOPMENT SHALL BE THE DEVELOPER TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED
TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE.
4. ALL EXISTING PERIMETER ROAD DRAINAGE STRUCTURES AND BRIDGES ACROSS THE FRONTAGE OF THIS
DEVELOPMENT ARE INDICATED ON THE PLANS. PROVISIONS HAVE BEEN MADE TO IMPROVE OR REPLACE ANY
DRAINAGE STRUCTURES AND BRIDGES AS NECESSARY OR AS REQUEST BY THE CITY TO ACCOMMODATE THE
PAVEMENT WIDENING, AUXILIARY LANES, MULTI-USE PATH, AND ANY OTHER REQUIRED IMPROVEMENTS TO
THE PROPERTY OR THE ROADWAY. THE COST TO IMPROVE OR REPLACE ANY DRAINAGE STRUCTURES AND
BRIDGES WILL BE BORNE BY THE DEVELOPER.
5. DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE
CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE
RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING
CONDITION OF THE RIGHT-OF-WAY.
6. ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT -OF-WAY SHALL CONFORM TO THE
REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE
DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE
DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED
INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS
IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY.
DESIGN DATA
EXISTING ZONING: I-1
ZONING OVERLAY: RANGELINE OVERLAY (RL-OL)
TOTAL ACREAGE: 4.37 ACRES
NET ACREAGE: 4.37 ACRES
LIMITS OF DISTURBANCE: 1.20 ACRES
BUILDING COVER RATIO: 11%
BUILDING SQUARE FOOTAGE: 20,121 SQUARE FEET
IMPERVIOUS COVER RATIO: 87% (MAXIMUM ALLOWED - 90%)
SETBACKS: 0' FRONT, 0' BACK
07/14/21
W
W W
G
G
N00°01'56"W(M)N00°49'00"E(D)178.64'(M) 180.08'(D)WEST C
A
R
M
E
L
D
R
I
V
E
S00°05'46"E(M) S00°45'10"W(D) 411.64'N00°05'46"W(M) N00°45'10"E(D) 398.63'S89°17'51"W(M) N89°51'24"W(D) 226.23' S89°17'51"W(M) N89°51'24"W(D) 206.01'
N89°25'05"E(M) S89°43'58"E(D) 206.02'
N00°50'56"W(M)
N89°26'06"E(M) S89°42'58"E(D) 189.95'S00°50'56"E(M)S00°00'00"E (D)181.33'(M) 182.73'(D)N89°48'49"E(M) S89°20'15"E(D) 190.00
' N89°25'05"E(M) S89°43'58"E(D) 241.02'
N00°01'56"W(M)
N00°49'00"E(D)
4.56'S89°17'51"W(M)
N89°51'24"W(D)
299.23'
DELTA=10°06'20"
R=561.07'
T=49.61'
L=98.96'
CH BRG=N83°08'42"W(M)
CH LEN=98.83'G G G GGWW WWC
EEE EEE E EE EE
E
W WG GGGG
C C CC C C C CCCC100EXISTING CONDITIONSW190582-C100 existing conditionsREVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, IndianaW19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWEXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJSE N G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
W
S
N
E
EXISTING AREAS
TOTAL SITE = 4.37 AC.
DISTURBED = 1.20 AC.
PERVIOUS = 0.65 AC.
IMPERVIOUS = 3.72 AC.
PROJECT BM
HARRISON MONUMENT AT THE EAST QUARTER CORNER OF SECTION 36, TOWNSHIP18
NORTH, RANGE 03 EAST PER HAMILTON COUNTY SURVEYOR'S OFFICE CORNER
NUMBER 18033606. LOCATED IN THE SOUTHBOUND LANE OF RANGELINE ROAD
APPROXIMATELY 190 FEET NORTH OF THE INTERSECTION OF EXECUTIVE DRIVE AND
RANGELINE ROAD.
ELEV.844.55 (NAVD 88)
SITE TBM
CUT 'X' ON THE SOUTH BONNET BOLT OF A FIRE HYDRANT LOCATED APPROXIMATELY 22
FEET NORTHWEST OF THE NORTHWEST CORNER OF THE SURVEYED REAL ESTATE ON
THE SOUTH SIDE OF CARMEL DRIVE.
ELEV.831.54 (NAVD 88)
BENCHMARK INFORMATION
DEMO ASPHALT
EXISTING CONCRETE
EXISTING ASPHALT
STONE
* SITE DISCHARGE POINT
07/14/21
*
C101EXISTING CONDITIONSW190582-C100 existing conditionsREVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, IndianaW19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWEXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJSENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
W
S
N
E
PROJECT BM
HARRISON MONUMENT AT THE EAST QUARTER CORNER OF SECTION 36, TOWNSHIP18
NORTH, RANGE 03 EAST PER HAMILTON COUNTY SURVEYOR'S OFFICE CORNER
NUMBER 18033606. LOCATED IN THE SOUTHBOUND LANE OF RANGELINE ROAD
APPROXIMATELY 190 FEET NORTH OF THE INTERSECTION OF EXECUTIVE DRIVE AND
RANGELINE ROAD.
ELEV.844.55 (NAVD 88)
SITE TBM
CUT 'X' ON THE SOUTH BONNET BOLT OF A FIRE HYDRANT LOCATED APPROXIMATELY 22
FEET NORTHWEST OF THE NORTHWEST CORNER OF THE SURVEYED REAL ESTATE ON
THE SOUTH SIDE OF CARMEL DRIVE.
ELEV.831.54 (NAVD 88)
BENCHMARK INFORMATION
DEMO ASPHALT
EXISTING CONCRETE
EXISTING ASPHALT
STONE
* SITE DISCHARGE POINT
EXISTING AREAS
TOTAL SITE = 4.37 AC.
DISTURBED = 1.20 AC.
PERVIOUS = 0.65 AC.
IMPERVIOUS = 3.72 AC.
07/14/21
8
E
OHU OHU OHUOHU OHU OHU OHU OHU
OHU
OH U
OHU
OHU
OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OH U
G
W
W W
G
G
W
WEST C
A
R
M
E
L
D
R
I
V
E
G G G G GW W WW C
EEE EEEEE EEE
E
W WG GGGG
C C CC C C CC CCD D D D D DDD DD D D D D D DD
D
D
D
D D D D D D D D D D D D D D D DD D D D D D D D D D D D D D D D D D D DSTM STM STM STM STM STMSTM STM STM STM STM STM STMESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
DRY POND
RIP RAP REVETMENT PAD
9
13 17
16
14
14
6
6
20
20
7
7
77
7
8
9
22
22
10
15
7
17
2
2
SD SD SD SD SD SD SD SD SD SD SD SD SD SDIP
SFSF SF SF SF SFSF SF SF SF SF SF SF SFSF
SFIP
IPIP
IP
1
3
19 SFSF SF SFSF SFSF4
4
4
5
5
5
7
21
10
9
11 12
15
15
18
4
4
22 23
2 2
10
10
13
10
16
21
24
25
2626
2
SF
SF
4
22
22
25
25
GENERAL NOTES
1. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO
VERIFY WITH THE OWNER DURING BIDDING AND DURING
CONSTRUCTION ACTIVITIES ALL ITEMS TO BE REMOVED. IT IS THE
RESPONSIBILITY OF THE CONTRACTOR TO REMOVE ANY
MATERIALS AND/OR STRUCTURES NOT LOCATED ON THIS SURVEY
FOR THE INSTALLATION OF THE NEW WORK.
2. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO
VERIFY ALL EXISTING UTILITIES PERTAINING TO THEIR PHASE OF
WORK, AND TO VERIFY WHICH UTILITIES WILL BE REMOVED BY
UTILITY COMPANY. ANY AND ALL UTILITIES NOT REMOVED BY THE
UTILITY COMPANY SHALL BE REMOVED BY THE CONTRACTOR.
3. UTILITIES ARE SHOWN TO BE APPROXIMATE AND SHALL BE
RELOCATED AND/OR CAPPED AND ABANDONED BEFORE
CONSTRUCTION AT NO ADDITIONAL COST TO THE OWNER.
4. ALL DEMOLITION MATERIAL AND SALVAGEABLE MATERIAL IS THE
PROPERTY OF THE DEMOLITION CONTRACTOR AND SHALL BE
PROPERLY DISPOSED OF OFF THE SITE.
5. SLABS ON GRADE MUST BE REMOVED COMPLETELY AND TAKEN
OFF THE SITE.
6. ALL UTILITIES MUST REMAIN ACTIVE FOR AREA TENANTS THAT
ARE REMAINING. NO UTILITY SERVICE SHALL BE INTERRUPTED
DURING THE CONSTRUCTION PROCESS.
7. BEARINGS, DIMENSIONS, AND EASEMENTS ARE SHOWN FOR
REFERENCE ONLY. SEE RECORD SURVEYS AND PLATS FOR
EXACT INFORMATION.
8. ANY EXISTING TREE(S) THAT MAY REQUIRE REMOVAL BUT ARE
NOT SHOWN ON THE PLAN AS BEING REMOVED MAY BE DONE SO,
AS LONG AS THE TREE(S) ARE RELOCATED TO AN APPROVED
ALTERNATIVE LOCATION ON SITE.
9. IF THERE ARE ANY QUESTIONS CONCERNING THIS DEMOLITION
PLAN, PLEASE CONTACT THE ENGINEER BEFORE CONTINUING
WORK.
10. CONTRACTOR TO CONNECT BACK ANY FIELD TILES FOUND DURING
EXCAVATION AND MAINTAIN POSITIVE DRAINAGE.
SITE PREPARATION / SWPPP PHASE 1 NOTES
INSTALL PERMIT POSTING AREA. 4" PVC TUBE WITH END CAPS ATTACHED TO
PROJECT CONSTRUCTION SIGN TO CONTAIN APPROVED CONSTRUCTION
DRAWINGS AND PERMITS FOR INSPECTORS.
USE EXISTING DRIVE AS CONSTRUCTION ENTRANCE. REFER TO DETAIL ON SHEET
C105 IF THE ENTIRE ASPHALT DRIVE IS REMOVED DURING CONSTRUCTION.
INSTALL CONCRETE WASHOUT. REFER TO DETAIL ON SHEET C105
INSTALL SILT FENCE. REFER TO DETAIL ON SHEET C105
INSTALL SILT WORM OR EQUAL. REFER TO DETAIL ON SHEET C106
LIMITS OF PROPOSED BUILDING
REMOVE STORM SEWER LINE(S) AND APPURTENANCES AS SHOWN. COORDINATE
WITH SHEET C600 FOR NEW LOCATION(S).
DISCONNECT AND RELOCATE SANITARY SEWER LINE(S) AND APPURTENANCES AS
SHOWN. COORDINATE WITH SHEET C800, ARCHITECTURAL DRAWINGS AND
SERVICE PROVIDER FOR NEW LOCATION(S).
DISCONNECT AND RELOCATE WATER SERVICE LINE(S) AND APPURTENANCES AS
SHOWN. COORDINATE WITH SHEET C800, ARCHITECTURAL DRAWINGS AND
SERVICE PROVIDER FOR NEW LOCATION(S).
DISCONNECT AND RELOCATE ELECTRIC SERVICE LINE(S) AND APPURTENANCES
AS SHOWN. COORDINATE WITH SHEET C800, ARCHITECTURAL DRAWINGS AND
SERVICE PROVIDER FOR NEW LOCATION(S).
DISCONNECT AND RELOCATE TELEPHONE SERVICE LINE(S) AND APPURTENANCES
AS SHOWN. COORDINATE WITH SHEET C800, ARCHITECTURAL DRAWINGS AND
SERVICE PROVIDER FOR NEW LOCATION(S).
DISCONNECT AND RELOCATE CABLE SERVICE LINE(S) AND APPURTENANCES AS
SHOWN. COORDINATE WITH SHEET C800, ARCHITECTURAL DRAWINGS AND
SERVICE PROVIDER FOR NEW LOCATION(S).
DISCONNECT AND RELOCATE GAS SERVICE LINE(S) AND APPURTENANCES AS
SHOWN. COORDINATE WITH SHEET C800, ARCHITECTURAL DRAWINGS AND
SERVICE PROVIDER FOR NEW LOCATION(S). CONTACT CHAD MILLER WITH
VECTREN TO HAVE THE SERVICE LINE AND METER RETIRED OR RELOCATED
PRIOR TO THE EXISTING BUILDING BEING DEMOLISHED.
REMOVE BUILDING AND APPURTENANCES FROM EXISTING BUILDING LOCATION.
REMOVE EXISTING CONCRETE STOOPS TO NEAREST JOINT (IF APPLICABLE)
SAWCUT AND REMOVE EXISTING PAVEMENT FULL DEPTH.
REMOVE EXISTING LANDSCAPING AND VEGETATION
REMOVE EXISTING SIGN
STAGING AREA. PROVIDE CONSTRUCTION DUMPSTER, FUELING AREA, AND
PORT-O-LET AS NEEDED.
REMOVE EXISTING BOLLARDS
REMOVE AND RELOCATE EXISTING WHEEL STOPS
REMOVE EXISTING FENCE
REMOVE EXISTING GATE
RAISE STRUCTURE TO THE NEW PAVEMENT GRADE. REFER TO SHEET C300 FOR
NEW ELEVATIONS.
SAWCUT AND REMOVE PAVEMENT FOR NEW WATER TAP AND STORM SEWER.
REMOVE END SECTIONS. 15" PIPES TO BE EXTENDED. REFER TO SHEET C600.
C102STORMWATER POLLUTION PREVENTION PLAN PHASE IW190582-C100 swppp1SWPPP PHASE 1 LEGEND
- INLET PROTECTION - USE SUBSURFACE
INLET PROTECTION WITH OVERFLOW
CAPABILITY
- STAGING AREA
- POSTING AREA - 4" PVC TUBE WITH END CAPS
ATTACHED TO PROJECT CONSTRUCTION SIGN
TO CONTAIN APPROVED CONSTRUCTION
DRAWINGS AND PERMITS FOR INSPECTORS.
- SILT WORM OR EQUAL
- CONCRETE WASHOUT
- SILT FENCE
- LIMITS OF DISTURBANCE
SD
IP
SF
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
D
EROSION CONTROL NOTES
1. ALL DISTURBED AREAS SHALL BE SODDED OR SEEDED, EXCEPT
BUILDING PAD AND LANDSCAPE BEDS. SEE LANDSCAPE PLANS FOR
LOCATION OF LANDSCAPE BEDS.
2. INSTALL SILT FENCE ALONG ALL DOWNSTREAM SLOPES. SILT
FENCE TO FOLLOW CONTOUR.
3. THERE SHALL BE NO DIRT, DEBRIS OR STORAGE OF MATERIAL IN
THE STREET.
CONTACT PERSON FOR EROSION
CONTROL & SEDIMENT PRACTICES
EROSION CONTROL SPECIFICATIONS
1. THIS PLAN IS DESIGNED AS AN ATTEMPT TO PREVENT ANY AND ALL
SEDIMENT FROM LEAVING THE CONSTRUCTION SITE BY WAY OF
EROSION. IF EROSION OF SEDIMENT FROM THE SITE IS TAKING
PLACE, THE CONTRACTOR AND/OR OWNER SHALL TAKE
PREVENTATIVE ACTION IMMEDIATELY. THE ENGINEER SHALL BE
CONSULTED IN THE EVENT THIS HAPPENS.
2. TEMPORARY SEEDING IS TO BE APPLIED TO ANY DISTURBED AREA
THAT WILL REMAIN UNALTERED IN EXCESS OF 15 DAYS.
3. PERMANENT SEEDING IS TO BE APPLIED IMMEDIATELY TO AREAS
THAT HAVE ACHIEVED FINAL AND FINISHED GRADE.
4. PRESERVE EXISTING VEGETATION ON THE SITE WHENEVER AND
WHEREVER POSSIBLE TO PREVENT TOPSOIL EROSION.
5. ALL SEDIMENT CAPTURING MEASURES SHALL BE IMPLEMENTED
PRIOR TO THE DISTURBANCE OF THE CONSTRUCTION AREA THEY
ARE INTENDED TO SERVICE. ALL EROSION CONTROL MEASURES
PROPOSED ARE TO BE PROPERLY MAINTAINED TO CONTINUE THEIR
EFFECTIVENESS.
6. IF GRADING OCCURS DURING THE MONTHS OF DECEMBER, JANUARY
OR FEBRUARY DORMANT SEEDING PROCEDURES SHALL BE USED.
7. DURING DRY WEATHER, KEEP LAWNS WATERED WITH SPRINKLERS
OR OTHER APPROVED METHODS. RESEED ANY AREAS NOT
GERMINATING OR DAMAGED AT INTERVALS AS MAY BE REQUIRED
ACCORDING TO SEASONAL CONDITION AND/OR CONSTRUCTION
ACTIVITY. WATER GRASS AND EXECUTE NECESSARY WEEDING UNTIL
FULL STAND OF GRASS HAS BEEN OBTAINED.
8. THE IMPLEMENTATION AND MAINTENANCE OF THE EROSION
CONTROL IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR
AND/OR OWNER.
9. IT SHALL BE THE CONTRACTOR'S AND/OR OWNER'S RESPONSIBILITY
TO MINIMIZE SEDIMENTATION (FROM ON-SITE CONSTRUCTION
ACTIVITIES) FROM BEING DEPOSITED ONTO ADJACENT PROPERTIES
AND RECEIVING STREAMS/DITCHES IN STRICT COMPLIANCE WITH
"RULE 5" (327 IAC 15-5, CONSTRUCTION ACTIVITY STORM WATER
RUNOFF CONTROL). IT SHALL ALSO BE THE CONTRACTOR'S AND/OR
OWNER'S RESPONSIBILITY TO OBTAIN ANY APPROVALS REQUIRED
FROM THE LOCAL AUTHORITY AND TO SUBMIT A COMPLETE NOTICE
OF INTENT LETTER TO THE OFFICE OF WATER MANAGEMENT,
INDIANA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT PRIOR TO
ANY CONSTRUCTION ACTIVITY.
10. FOR SEASONAL VARIATIONS - SEE SEASONAL SOIL PROTECTION
CHART IN THESE PLANS.
11. PORTABLE TOILETS MUST BE ANCHORED.
WEIHE ENGINEERS, INC.
10505 N. COLLEGE AVE.
INDIANAPOLIS, IN 46268
TELEPHONE: (317) 846-6611
FAX: (317) 843-0546
EMAIL: PARKERF@WEIHE.NET
CONTACT PERSON: FRED PARKER, CPESC
LINE TYPES
UNDERGROUND GAS
UNDERGROUND WATER
AERIAL ELECTRIC
UNDERGROUND ELECTRIC
UNDERGROUND COMMUNICATIONS
AERIAL COMMUNICATIONS
OVERHEAD UTILITY
FORCE MAIN
RIGHT OF WAY LINE
CHAIN LINK FENCE
BOARD FENCE
WROUGHT IRON FENCE
GUARD RAIL
HAND RAIL
SILT FENCE
BUILDING SETBACK LINE
BOUNDARY LINE
FLOW LINE
G G G
W W
E(A) E(A)
E E E
C C C
C(A) C(A)
OHU OHU
FM FM
SF SF
AERIAL FIBER OPTIC CABLEFO(A) FO(A)
SECTION LINE
FARM FENCE
UNDERGROUND FIBER OPTICFO FO
INDEX CONTOUR
INTERMEDIATE CONTOUR
SANITARY SEWER
STORM SEWER REVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, Indiana W19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
EXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJS
W
S
N
E E N GI N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil Engi neeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
PROJECT BM
HARRISON MONUMENT AT THE EAST QUARTER CORNER OF SECTION 36, TOWNSHIP18
NORTH, RANGE 03 EAST PER HAMILTON COUNTY SURVEYOR'S OFFICE CORNER
NUMBER 18033606. LOCATED IN THE SOUTHBOUND LANE OF RANGELINE ROAD
APPROXIMATELY 190 FEET NORTH OF THE INTERSECTION OF EXECUTIVE DRIVE AND
RANGELINE ROAD.
ELEV.844.55 (NAVD 88)
SITE TBM
CUT 'X' ON THE SOUTH BONNET BOLT OF A FIRE HYDRANT LOCATED APPROXIMATELY
22 FEET NORTHWEST OF THE NORTHWEST CORNER OF THE SURVEYED REAL ESTATE
ON THE SOUTH SIDE OF CARMEL DRIVE.
ELEV.831.54 (NAVD 88)
BENCHMARK INFORMATION
21
22
23
DEMO ASPHALT
EXISTING CONCRETE
EXISTING ASPHALT
EXISTING AREAS
TOTAL SITE = 4.37 AC.
DISTURBED = 1.20 AC.
PERVIOUS = 0.65 AC.
IMPERVIOUS = 3.72 AC.
24
25
26
ENTRANCE NOTE
CONTRACTOR TO KEEP THE EXISTING
DRIVE OPEN DURING CONSTRUCTION
TO ALLOW EMERGENCY EQUIPMENT
AND ACCESS TO BACK UNITS.
07/14/21
W
W W
W
WEST C
A
R
M
E
L
D
R
I
V
E
GGPROPOSED BUILDING
20,121SF± PER FLOOR
F.F.E. = 829.85
D D D D D DDD DD D D D D D DD
D
D
D
D D D D D D D D D D D D D D D DD D D D D D D D D D D D D D D D D D D DCSTM STM STM STM STM STMSTM STM STM STM STM STM STMESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS W W W W W W W W W W W W W WW W W WEE E E E E E E E EDRY POND
RIP RAP REVETMENT PAD
IP
IP
IP
IP SD SD SD SD SD SD SD SD SD SD SD SD SD SDSFSF SF SFSF SFSFIP
SF SF SF SF SF SFSF SF SF SF SF SF SF SFSF
SF
6
5
4
1
1
1
1
7
8
9
2
3
10 11
12
13
CONTACT PERSON FOR EROSION
CONTROL & SEDIMENT PRACTICES
WEIHE ENGINEERS, INC.
10505 N. COLLEGE AVE.
INDIANAPOLIS, IN 46268
TELEPHONE: (317) 846-6611
FAX: (317) 843-0546
EMAIL: PARKERF@WEIHE.NET
CONTACT PERSON: FRED PARKER, CPESC
-WARNING-
THIS PLAN TO BE USED FOR EROSION CONTROL
PURPOSES ONLY. ADDITIONAL EROSION
CONTROL MEASURES MAY BE REQUIRED IN THE
FIELD BY THE INSPECTOR.
-NOTE-
THIS PLAN INDICATES EROSION CONTROL
MEASURES REQUIRED AFTER SOIL STRIPPING
AND PAD BUILDING HAS TAKEN PLACE.
COORDINATE WITH DEVELOPER FOR
MEASURES REQUIRED UNTIL PROPERTY
TURNED OVER FOR DEVELOPMENT.
COORDINATE WITH SOIL CONSERVATION
DISTRICT REPRESENTATIVE FOR ANY OTHER
MEASURES REQUIRED DUE TO SITE
CONDITIONS.
DISTURBED ACREAGE
=1.20± AC.
LAND DESCRIPTION
C103STORMWATER POLLUTION PREVENTION PLAN PHASE IIW190582-C101 swppp2SWPPP PHASE 2 LEGEND
- INLET PROTECTION - USE SUBSURFACE
INLET PROTECTION WITH OVERFLOW CAPABILITY
- PERMANENT/TEMPORARY SEEDING
USE PLANTING CHART
- THE DRY POND BASIN BOTTOM TO BE PLANTED WITH NATIVE
SEED MIX THEN TOPPED WITH AN EROSION BLANKET
- EROSION CONTROL BLANKET - USE S150BN BIO-NET AS
SUPPLIED BY NORTH AMERICAN GREEN OR APPROVED
EQUAL
- LIMITS OF DISTURBANCE (CONSTRUCTION LIMITS)
IP
D
LINE TYPES
UNDERGROUND GAS
UNDERGROUND WATER
AERIAL ELECTRIC
UNDERGROUND ELECTRIC
UNDERGROUND COMMUNICATIONS
AERIAL COMMUNICATIONS
OVERHEAD UTILITY
FORCE MAIN
RIGHT OF WAY LINE
CHAIN LINK FENCE
BOARD FENCE
WROUGHT IRON FENCE
GUARD RAIL
HAND RAIL
SILT FENCE
BUILDING SETBACK LINE
BOUNDARY LINE
FLOW LINE
G G G
W W
E(A) E(A)
E E E
C C C
C(A) C(A)
OHU OHU
FM FM
SF SF
AERIAL FIBER OPTIC CABLEFO(A) FO(A)
SECTION LINE
FARM FENCE
UNDERGROUND FIBER OPTICFO FO
INDEX CONTOUR
INTERMEDIATE CONTOUR
SANITARY SEWER
STORM SEWER
EROSION CONTROL NOTES
1. ALL DISTURBED AREAS SHALL BE SODDED OR SEEDED, EXCEPT
BUILDING PAD AND LANDSCAPE BEDS. SEE LANDSCAPE PLANS FOR
LOCATION OF LANDSCAPE BEDS.
2. INSTALL SILT FENCE ALONG ALL DOWNSTREAM SLOPES. SILT
FENCE TO FOLLOW CONTOUR.
3. THERE SHALL BE NO DIRT, DEBRIS OR STORAGE OF MATERIAL IN
THE STREET.
EROSION CONTROL SPECIFICATIONS
1. THIS PLAN IS DESIGNED AS AN ATTEMPT TO PREVENT ANY AND ALL
SEDIMENT FROM LEAVING THE CONSTRUCTION SITE BY WAY OF
EROSION. IF EROSION OF SEDIMENT FROM THE SITE IS TAKING
PLACE, THE CONTRACTOR AND/OR OWNER SHALL TAKE
PREVENTATIVE ACTION IMMEDIATELY. THE ENGINEER SHALL BE
CONSULTED IN THE EVENT THIS HAPPENS.
2. TEMPORARY SEEDING IS TO BE APPLIED TO ANY DISTURBED AREA
THAT WILL REMAIN UNALTERED IN EXCESS OF 15 DAYS.
3. PERMANENT SEEDING IS TO BE APPLIED IMMEDIATELY TO AREAS
THAT HAVE ACHIEVED FINAL AND FINISHED GRADE.
4. PRESERVE EXISTING VEGETATION ON THE SITE WHENEVER AND
WHEREVER POSSIBLE TO PREVENT TOPSOIL EROSION.
5. ALL SEDIMENT CAPTURING MEASURES SHALL BE IMPLEMENTED
PRIOR TO THE DISTURBANCE OF THE CONSTRUCTION AREA THEY
ARE INTENDED TO SERVICE. ALL EROSION CONTROL MEASURES
PROPOSED ARE TO BE PROPERLY MAINTAINED TO CONTINUE THEIR
EFFECTIVENESS.
6. IF GRADING OCCURS DURING THE MONTHS OF DECEMBER, JANUARY
OR FEBRUARY DORMANT SEEDING PROCEDURES SHALL BE USED.
7. DURING DRY WEATHER, KEEP LAWNS WATERED WITH SPRINKLERS
OR OTHER APPROVED METHODS. RESEED ANY AREAS NOT
GERMINATING OR DAMAGED AT INTERVALS AS MAY BE REQUIRED
ACCORDING TO SEASONAL CONDITION AND/OR CONSTRUCTION
ACTIVITY. WATER GRASS AND EXECUTE NECESSARY WEEDING UNTIL
FULL STAND OF GRASS HAS BEEN OBTAINED.
8. THE IMPLEMENTATION AND MAINTENANCE OF THE EROSION
CONTROL IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR
AND/OR OWNER.
9. IT SHALL BE THE CONTRACTOR'S AND/OR OWNER'S RESPONSIBILITY
TO MINIMIZE SEDIMENTATION (FROM ON-SITE CONSTRUCTION
ACTIVITIES) FROM BEING DEPOSITED ONTO ADJACENT PROPERTIES
AND RECEIVING STREAMS/DITCHES IN STRICT COMPLIANCE WITH
"RULE 5" (327 IAC 15-5, CONSTRUCTION ACTIVITY STORM WATER
RUNOFF CONTROL). IT SHALL ALSO BE THE CONTRACTOR'S AND/OR
OWNER'S RESPONSIBILITY TO OBTAIN ANY APPROVALS REQUIRED
FROM THE LOCAL AUTHORITY AND TO SUBMIT A COMPLETE NOTICE
OF INTENT LETTER TO THE OFFICE OF WATER MANAGEMENT,
INDIANA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT PRIOR TO
ANY CONSTRUCTION ACTIVITY.
10. FOR SEASONAL VARIATIONS - SEE SEASONAL SOIL PROTECTION
CHART IN THESE PLANS.
11. PORTABLE TOILETS MUST BE ANCHORED.REVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, Indiana W19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
EXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJS
W
S
N
E E N GI N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil Engi neeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
PROJECT BM
HARRISON MONUMENT AT THE EAST QUARTER CORNER OF SECTION 36, TOWNSHIP18
NORTH, RANGE 03 EAST PER HAMILTON COUNTY SURVEYOR'S OFFICE CORNER
NUMBER 18033606. LOCATED IN THE SOUTHBOUND LANE OF RANGELINE ROAD
APPROXIMATELY 190 FEET NORTH OF THE INTERSECTION OF EXECUTIVE DRIVE AND
RANGELINE ROAD.
ELEV.844.55 (NAVD 88)
SITE TBM
CUT 'X' ON THE SOUTH BONNET BOLT OF A FIRE HYDRANT LOCATED APPROXIMATELY 22
FEET NORTHWEST OF THE NORTHWEST CORNER OF THE SURVEYED REAL ESTATE ON
THE SOUTH SIDE OF CARMEL DRIVE.
ELEV.831.54 (NAVD 88)
BENCHMARK INFORMATION
APPROXIMATELY 4.3 ACRES LOCATED AT 147 AND 155 WEST CARMEL DRIVE - PART
OF SOUTHEAST 14, SECTION 36, TOWNSHIP 18 NORTH, RANGE 3 EAST, CLAY
TOWNSHIP, HAMILTON COUNTY, INDIANA
DRAINAGE PLAN NOTES
DOWNSPOUTS TO CONNECT TO PROPOSED ROOF DRAIN. COORDINATE
WITH ARCHITECTURAL PLANS.
TRENCH DRAIN
CONNECT TRENCH DRAIN TO PROPOSED STRUCTURE
WATER QUALITY UNIT
CONTROL STRUCTURE
DIVERSION STRUCTURE
12' WIDE EMERGENCY OVERFLOW.
INSTALL NEW BEEHIVE STRUCTURE. CONNECT TO EXISTING 15" PIPE
AND EXTEND NEW 15" PIPE WEST TO NEW STRUCTURE WEST OF THE
PROPOSED SIDEWALK.
RECONNECT 6" OUTLET FROM THE DRAIN TO STRUCTURE 304.
NATIVE PLANTINGS WITHIN BASIN. REFER TO SPECS ON SHEET C601.
SIGN FOR NATIVE PLANTINGS. DETAIL ON SHEET C601.
CONNECT STRUCTURE 900 TO EXISTING 15" PIPE
STONE LEVEL SPREADER WITH UNDER DRAIN. REFER TO DETAIL ON
SHEET C601
1
2
3
4
5
6
7
8
9
10
11
12
13
07/14/21
SECTION 2 MATERIAL HANDLING AND
SPILL PREVENTION PLAN
IN ORDER TO MINIMIZE THE RELEASE OF POTENTIAL POLLUTANTS DURING
CONSTRUCTION THE CONTRACTORS SHALL IMPLEMENT THIS MATERIAL
HANDLING AND SPILL PREVENTION PLAN. THE CONTRACTOR SHALL REVIEW
THIS PLAN WITH ALL SUBCONTRACTORS AND REQUIRE THAT THEY IMPLEMENT
THE PLAN AS WELL.
1. CONSTRUCTION EQUIPMENT
A. FUELING, LUBRICATION AND FLUIDS: ALL OPERATIONS INVOLVING THE
ADDITION OF FLUIDS TO EQUIPMENT SHOULD BE DONE IN ONE LOCATION, AS
DESIGNATED BY THE CONSTRUCTION MANAGER, SO THAT SPILLS ARE LIMITED
TO ONE LOCATION ON THE SITE, WHICH WILL FACILITATE THE CLEANUP OF
SPILLS. IF AN ONSITE-FUELING TANK IS PLANNED TO BE ON SITE, IT SHALL BE
DOUBLE WALLED AND STORED IN THIS DESIGNED AREA. THIS LOCATION IS AN
AREA THAT WILL NOT ALLOW SPILLED FLUIDS TO MIGRATE INTO SUBSURFACE
SOILS. IN THE EVENT OF A SPILL, THE FLUID SHALL IMMEDIATELY BE CLEANED
UP BY REMOVING THE CONTAMINATED SOIL OR STONE, WHICH SHALL BE
DISPOSED OF IN AN ACCEPTABLE MANNER. SPILLS ON HARD SURFACES SHALL
BE SOAKED UP BY AN ACCEPTABLE MATERIAL SUCH AS OIL DRY AND THE
ABSORBENT MATERIAL DISPOSED OF IN A PROPER MANNER. THE SPILL SHALL
ALSO BE REPORTED IMMEDIATELY TO THE CONSTRUCTION MANAGER'S
SUPERINTENDENT.
B. EQUIPMENT REPAIR, ESPECIALLY WHEN FLUIDS MUST BE REMOVED FROM
THE EQUIPMENT OR THE POSSIBILITY OF FLUID SPILLS IS HIGH, SHOULD
ALWAYS BE DONE OFFSITE AT A FACILITY THAT IS MORE SUITABLE THAN A
CONSTRUCTION SITE TO HANDLE SPILLS. WHEN EQUIPMENT MUST BE
REPAIRED ONSITE IT SHOULD BE MOVED TO THE MAINTENANCE AND FUELING
AREA IF POSSIBLE. OTHERWISE, SUITABLE ON SITE CONTAINERS SHOULD BE
PLACED UNDER THE EQUIPMENT DURING REPAIR TO CATCH ANY SPILLED
FLUIDS AND THESE FLUIDS SHOULD BE DISPOSED OF IN A PROPER MANNER.
C. ALL REUSABLE FLUID CONTAINERS, SUCH AS GASOLINE CANS, SHALL BE
INSPECTED FOR LEAKS EACH TIME THEY ARE USED. IF LEAKS ARE FOUND, THE
FLUID SHALL BE REMOVED FROM THE CONTAINER IN A PROPER MANNER AND
THE CONTAINER DISPOSED OF IN AN ACCEPTABLE MANNER. EMPTY
DISPOSABLE CONTAINER, SUCH AS GREASE TUBES AND LUBRICATING OIL AND
BRAKE FLUID CONTAINERS, AND THEIR PACKAGING, SHALL BE DISPOSED OF IN A
PROPER MANNER AND SHALL NOT BE LEFT ON THE GROUND OR IN THE OPEN ON
THE CONSTRUCTION SITE.
2. CONSTRUCTION MATERIALS AND THEIR PACKAGING
A. EROSION CONTROL MEASURE SHOWN ON THE SUBJECT PROJECT SHALL BE
IMPLEMENTED PRIOR TO AND DURING CONSTRUCTION IN THE PROPER
SEQUENCING TO MINIMIZE SOIL EROSION. EROSION CONTROLS SHALL BE
INSPECTED AND MAINTAINED AS DESCRIBED ELSEWHERE ON THE PLANS.
EXCESSIVE DUSTING OF SOIL ON THE SITE SHALL BE MINIMIZED BY REDUCING
CONSTRUCTION TRAFFIC ACROSS BARE SOIL DURING DRY AND/OR WINDY
WEATHER, AND BY APPLYING WATER OR OTHER ACCEPTABLE DUST CONTROL
MEASURES TO THE SOIL. UPON COMPLETION OF CONSTRUCTION AND SUITABLE
ESTABLISHMENT OF PERMANENT VEGETATION, TEMPORARY EROSION CONTROL
MEASURES SUCH AS SILT FENCE, CHECK DAMS AND INLET PROTECTION
DEVICES SHALL BE REMOVED IN A MANNER TO MINIMIZE ADDITIONAL LAND
DISTURBANCE. ANY AREAS DISTURBED BY THESE OPERATIONS SHALL BE
PROPERLY REVEGATATED.
B. LARGE WASTE MATERIALS CREATED BY CUTTING, SAWING, DRILLING, OR
OTHER OPERATIONS SHALL BE PROPERLY DISPOSED OF IN SUITABLE WASTE
CONTAINERS. THE SITE SHALL BE CHECKED AT THE END OF THE DAY, AS A
MINIMUM, AND ALL WASTE MATERIALS, INCLUDING THOSE BLOWN ACROSS OR
OFF THE SITE BY WIND SHALL BE PICKED UP AND DISPOSED OF IN SUITABLE
CONTAINERS. WHERE POSSIBLE, OPERATIONS SUCH AS SAWING THAT CREATE
SMALL PARTICLES SHOULD BE PERFORMED IN ONE SPOT IN AN AREA
PROTECTED FROM WIND, AND WASTE PARTICLES COLLECTED AND DISPOSED
OF FREQUENTLY TO MINIMIZE WIND DISPERSAL. PACKAGING USED TO
TRANSPORT MATERIALS TO THE SITE FOR CONSTRUCTION OF THE FACILITY
SHALL BE DISPOSED OF PROPERLY, WHETHER THE MATERIAL IS TAKEN OUT OF
ITS PACKAGE AND INCORPORATED INTO THE PROJECT IMMEDIATELY OR
STORED ONSITE FOR FUTURE USE. PACKAGED MATERIALS STORED ONSITE
SHALL BE INSPECTED REGULARLY AND ANY LOOSE PACKAGING SHALL BE
REPAIRED OR DISPOSED OF PROPERLY.
C. ALL DEWATERING OF ACTIVITIES SHALL BE DONE IN ACCORDANCE TO GOOD
EROSION CONTROL PRACTICES. THESE PRACTICES SHOULD INCLUDE THE USE
OF DIRT BAGS SUCH AS SILT FENCE INLET PROTECTION. THE USE OF THESE
TYPES OF DEWATERING DEVICES WILL REMOVE LARGE QUANTITIES OF SILT,
SEDIMENT, AND DIRT AND PREVENT THESE MATERIALS TO ENTER THE STORM
SEWER SYSTEM.
D. IF THE USE OF LIME IS USED TO STABILIZE THE SOIL OF THE SITE THEN ALL
CONSTRUCTION EQUIPMENT USED SHALL BE CLEANED OF ALL EXCESS
MATERIAL WITH WATER IN THE MAINTENANCE AND REFUELING AREA AS SHOWN
WITHIN THESE PLANS.
E. NUTRIENTS AND FERTILIZERS SHALL ONLY BE USED TO ESTABLISH RAPID
VEGETATION. WHEN THESE PRODUCTS ARE UTILIZED, THE USER SHOULD PAY
STRICT ATTENTION TO THE PRODUCTS RECOMMENDED USAGE.
3. CONCRETE WASTE WATER
A. ALL CONCRETE WASTEWATER SHALL BE DISPOSED OF IN THE DESIGNED
AREA AS DIRECTED BY THE CONSTRUCTION MANAGER. THIS AREA IS TO BE A 3'
DEEP, 10' SQUARE PIT AS DETAILED ON THE EROSION CONTROL PLAN. THIS
AREA SHALL BE INSPECTED ON A DAILY BASIS AT A MINIMUM. WHEN THIS AREA
BECOMES FULL, THE POLLUTANTS SHALL BE EXCAVATED, PLACED IN AN
ACCEPTABLE CONTAINER AND DISPOSED OF IN PROPER MANNER, BY THE
EXCAVATION CONTRACTOR.
4. PAINT PRODUCTS
A. ALL EXCESS PAINT AND THEIR RELATED PRODUCTS SHALL BE DISPOSED OF
IN THE MANNER AT WHICH THE MANUFACTURER SUGGESTS. UNDER NO
CIRCUMSTANCES WILL PAINT OR THEIR RELATED PRODUCTS BE CLEANED OR
DISPOSED OF IN SOIL, SANITARY SEWERS, STORM SEWERS OR DETENTION
BASINS. ANY VIOLATION OF THIS SHALL BE REPORTED TO THE JOB
SUPERINTENDENT.
IN THE EVENT OF ACCIDENTALLY CONTAMINATION ALL EFFORTS SHOULD BE
MADE TO REMOVE CONTAMINANTS IN AN APPROPRIATE MANNER. THE CARMEL
FIRE DEPARTMENT SHOULD BE CONTACTED IMMEDIATELY TO DETERMINE IF
FURTHER MEASURES ARE NEEDED.
SECTION 1 EMERGENCY RESPONSE NUMBERS
EMERGENCY FOR ANY LIFE THREATENING PROBLEM 911
CARMEL FIRE DEPARTMENT 317-571-2600
CARMEL POLICE DEPARTMENT 317-571-2500
INDIANA DEPT. OF NATURAL RESOURCES 812-477-8773
INDIANA DEPT. OF ENVIRONMENTAL MANAGEMENT 317-233-7745
HAMILTON COUNTY COUNTY SOIL AND WATER 317-773-1406
CITY OF CARMEL ENGINEERING 317-571-2441
RULE 6. SPILLS OF OIL AND OTHER
OBJECTIONABLE SUBSTANCES;
REPORTING, CONTAINMENT AND CLEANUP
(REPEALED BY WATER POLLUTION CONTROL BOARD; FILED FEB 25, 1997, 1:00 P.M.: 20 IR
1734)
RULE 6.1. SPILLS; REPORTING, CONTAINMENT, AND RESPONSE
327 IAC 2-6.1-1 APPLICABILITY
AUTHORITY: IC 13-14-8-7
AFFECTED: IC 13-11-2; IC 13-18-1; IC 13-18-3; IC 13-18-8; IC 13-18-17
SEC. 1. THIS RULE APPLIES TO THE REPORTING AND CONTAINMENT OF, AND THE
RESPONSE TO THOSE SPILLS OF HAZARDOUS SUBSTANCES,
EXTREMELY HAZARDOUS SUBSTANCES, PETROLEUM, AND OBJECTIONABLE
SUBSTANCES THAT ARE OF A QUANTITY, TYPE, DURATION AND IN A LOCATION AS
TO DAMAGE THE WATERS OF THE STATE. NOTHING IN THIS RULE IS INTENDED TO
AFFECT REPORTING OR CLEAN-UP REQUIREMENTS SET FORTH BY OTHER
FEDERAL, STATE, OR LOCAL LAWS. (WATER POLLUTION CONTROL BOARD; 327 IAC
2-6.1-1; FILED FEB 25, 1997, 1:00 P.M.: 20 IR 1731; READOPTED
FILED JAN 10, 2001, 3:23 P.M.: 24 IR 1518; READOPTED FILED NOV 21, 2007, 1:16 P.M.:
20071219-IR-327070553BFA)
327 IAC 2-6.1-2 SPECIAL AREAS
AUTHORITY: IC 13-14-8-7
AFFECTED: IC 13-11-2; IC 13-18-1; IC 13-18-3; IC 13-18-8; IC 13-18-17
SEC. 2. CERTAIN AREAS OF THE STATE ARE RECOGNIZED AS HAVING UNIQUE
GEOLOGY. A LARGE SECTION OF THE MID-SOUTHERN PART OF THE STATE IS A KARST
REGION. PORTIONS OF SAINT JOSEPH, ELKHART, KOSCIUSKO, AND LAGRANGE
COUNTIES CONTAIN A SOLE SOURCE AQUIFER AS REFERENCED
IN 42 U.S.C. 300H-3(E). THE WATERS OF THE STATE ARE PARTICULARLY VULNERABLE TO
DAMAGE FROM SPILLS IN THESE AREAS, AND CARE SHOULD BE
EXERCISED WHEN EVALUATING DAMAGE FROM SPILLS. INFORMATION ABOUT THESE
AREAS CAN BE OBTAINED BY CALLING THE DEPARTMENT OF ENVIRONMENTAL
MANAGEMENT, OFFICE OF LAND QUALITY, EMERGENCY RESPONSE SECTION: AREA
CODE 1-888-233-7745 FOR IN-STATE CALLS (TOLL FREE), (317) 233-7745 FOR
OUT-OF-STATE CALLS. (WATER POLLUTION CONTROL BOARD; 327 IAC 2-6.1-2; FILED FEB
25, 1997, 1:00 P.M.: 20 IR 1731; READOPTED FILED JAN 10, 2001, 3:23 P.M.: 24 IR 1518;
READOPTED FILED NOV 21, 2007, 1:16 P.M.: 20071219-IR-327070553BFA; ERRATA FILED
MAY 27, 2008, 2:06 P.M.: 20080625-IR-327080419ACA)
327 IAC 2-6.1-3 EXCLUSIONS
AUTHORITY: IC 13-14-8-7
AFFECTED: IC 13-11-2; IC 13-18-1; IC 13-18-3; IC 13-18-8; IC 13-18-17
SEC. 3. NOTWITHSTANDING ANY OTHER SECTION OF THIS RULE, THE REPORTING
REQUIREMENT OF THIS RULE DOES NOT APPLY TO THE FOLLOWING
OCCURRENCES:
(1) DISCHARGES OR EXCEEDANCES THAT ARE UNDER THE JURISDICTION OF AN
APPLICABLE PERMIT WHEN THE SUBSTANCE IN QUESTION IS COVERED
BY THE PERMIT AND DEATH OR ACUTE INJURY OR ILLNESS TO ANIMALS OR HUMANS
DOES NOT OCCUR.
(2) LAWFUL APPLICATION OF MATERIALS, INCLUDING, BUT NOT LIMITED TO:
(A) COMMERCIAL OR NATURAL FERTILIZERS AND PESTICIDES ON OR TO
LAND OR WATER; OR
(B) DUST SUPPRESSION MATERIALS.
(3) THE APPLICATION OF PETROLEUM NECESSARY FOR CONSTRUCTION THAT DOES NOT
DAMAGE WATERS OF THE STATE.
(4) SPILLS OF LESS THAN ONE (1) POUND OR ONE (1) PINT.
(5) SPILLS OF INTEGRAL OPERATING FLUIDS, IN THE USE OF MOTOR VEHICLES OR
OTHER EQUIPMENT, THE TOTAL VOLUME OF WHICH IS LESS THAN OR EQUAL TO
FIFTY-FIVE (55) GALLONS AND WHICH DO NOT DAMAGE WATERS OF THE STATE.
(6) OIL SHEENS PRODUCED AS A RESULT OF THE NORMAL OPERATION OF PROPERLY
FUNCTIONING WATERCRAFT.
(7) A RELEASE OF A SUBSTANCE INTEGRAL TO A SPILL RESPONSE ACTIVITY THAT HAS
BEEN APPROVED AND AUTHORIZED BY A STATE OR FEDERAL ONSCENE
COORDINATOR. (WATER POLLUTION CONTROL BOARD; 327 IAC 2-6.1-3; FILED FEB 25,
1997, 1:00 P.M.: 20 IR 1731; ERRATA FILED MAR 7, 1997, 2:25 P.M.:
20 IR 1738; READOPTED FILED JAN 10, 2001, 3:23 P.M.: 24 IR 1518; READOPTED FILED NOV
21, 2007, 1:16 P.M.: 20071219-IR-327070553BFA)
327 IAC 2-6.1-4 DEFINITIONS
AUTHORITY: IC 13-14-8-7
AFFECTED: IC 13-11-2; IC 13-18-1; IC 13-18-3; IC 13-18-8; IC 13-18-17; IC 14-8-2-7; IC
14-25-7-13; IC 14-25-7-15
SEC. 4. IN ADDITION TO THE DEFINITIONS CONTAINED IN IC 13-11-2-17(D), IC
13-11-2-35(A), IC 13-11-2-51, IC 13-11-2-158(A), IC 13-11-2-160, IC 13-11-2-260, IC 13-11-2-265,
AND IN 327 IAC 1, THE FOLLOWING DEFINITIONS APPLY THROUGHOUT THIS RULE:
(1) "ANIMAL" MEANS ALL MAMMALS, BIRDS, REPTILES, AMPHIBIANS, FISH, CRUSTACEANS,
AND MOLLUSKS.
(2) "AQUATIC LIFE" MEANS THOSE PLANTS AND MACROINVERTEBRATES THAT ARE
DEPENDENT UPON AN AQUATIC ENVIRONMENT.
(3) "CONTAIN" MEANS TO TAKE SUCH IMMEDIATE ACTION AS NECESSARY TO DAM,
BLOCK, RESTRAIN, OR OTHERWISE ACT TO MOST EFFECTIVELY
PREVENT A SPILL FROM ENTERING WATERS OF THE STATE OR MINIMIZE DAMAGE TO
THE WATERS OF THE STATE FROM A SPILL.
(4) "DAMAGE" MEANS THE ACTUAL OR IMMINENT ALTERATION OF THE WATERS OF THE
STATE SO AS TO RENDER THE WATERS HARMFUL, DETRIMENTAL,
OR INJURIOUS TO:
(A) PUBLIC HEALTH, SAFETY, OR WELFARE;
(B) DOMESTIC, COMMERCIAL, INDUSTRIAL, AGRICULTURAL, OR RECREATIONAL
USES; OR
(C) ANIMALS OR AQUATIC LIFE.
(5) "DOWNSTREAM WATER USER" MEANS:
(A) A COMMUNITY PUBLIC WATER SUPPLY, AS IDENTIFIED BY THE
DEPARTMENT OF NATURAL RESOURCES UNDER IC 14-25-7-13(D);
(B) A SIGNIFICANT WATER WITHDRAWAL FACILITY AS REGISTERED WITH THE
DEPARTMENT OF NATURAL RESOURCES UNDER IC 14-25-7-15;
(C) USERS OF RECREATIONAL WATERS; OR
(D) ANY OTHER USER MADE KNOWN TO THE PERSON WHO HAS A SPILL.
(6) "EXTREMELY HAZARDOUS SUBSTANCE" MEANS A SUBSTANCE IDENTIFIED PURSUANT
TO 42 U.S.C. 11002 AND 11004. (40 CFR 355 APPENDIX A.)
(7) "FACILITY" MEANS ALL LAND, BUILDINGS, EQUIPMENT, STRUCTURES, AND OTHER
STATIONARY ITEMS THAT ARE LOCATED ON A SINGLE SITE OR
ON CONTIGUOUS SITES AND THAT ARE OWNED OR OPERATED BY THE SAME PERSON OR
BY ANY PERSON WHO CONTROLS, IS CONTROLLED BY, OR IS
UNDER COMMON CONTROL WITH, SUCH PERSON.
(8) "FACILITY BOUNDARY" MEANS THE BOUNDARY OF A FACILITY OR AN EASEMENT OR
RIGHT-OF-WAY.
(9) "HAZARDOUS SUBSTANCE" HAS THE MEANING SET FORTH IN 42 U.S.C. 9601(14).
(10) "MODE OF TRANSPORTATION" INCLUDES, BUT IS NOT LIMITED TO, CARRIAGE BY:
(A) RAIL AND MOTOR VEHICLES;
(B) AIRCRAFT;
(C) WATERCRAFT;
(D) PIPELINES; OR
(E) OTHER MEANS OF TRANSPORTATION;
IN COMMERCE. THIS DEFINITION EXCLUDES CARRIAGE WITHIN A FACILITY BY
TRANSPORTATION EQUIPMENT OWNED, OPERATED, OR CONTROLLED BY THAT
FACILITY.
(11) "OBJECTIONABLE SUBSTANCES" MEANS SUBSTANCES THAT ARE:
(A) OF A QUANTITY AND A TYPE; AND
(B) PRESENT FOR A DURATION AND IN A LOCATION;
SO AS TO DAMAGE WATERS OF THE STATE. THIS DEFINITION EXCLUDES
HAZARDOUS SUBSTANCES, EXTREMELY HAZARDOUS SUBSTANCES,
PETROLEUM, AND MIXTURES THEREOF.
(12) "ON-SCENE COORDINATOR" MEANS A STATE OR FEDERAL OFFICIAL
DESIGNATED BY THE DEPARTMENT, THE UNITED STATES ENVIRONMENTAL
PROTECTION AGENCY, OR THE UNITED STATES COAST GUARD TO DIRECT AND
COORDINATE SPECIAL SPILL RESPONSE ACTIVITIES.
(13) "RECREATIONAL WATERS" MEANS ANY WATER USED FOR:
(A) BOATING, SWIMMING, FISHING, HUNTING, TRAPPING, OR WILDLIFE
VIEWING; OR
(B) PUBLIC ACCESS AREAS THAT ARE OWNED BY THE DEPARTMENT OF
NATURAL RESOURCES OR THE FEDERAL GOVERNMENT; AS LISTED BY THE
DEPARTMENT.
(14) "REPORTABLE QUANTITY" MEANS THE AMOUNT OF A HAZARDOUS
SUBSTANCE OR EXTREMELY HAZARDOUS SUBSTANCE THAT IS REQUIRED TO BE
REPORTED UNDER FEDERAL LAW UNDER 42 U.S.C. 9602(A) AND (B) AND 42 U.S.C.
9603(A). (40 CFR 302.4 OR 40 CFR 355 APPENDIX A.) (15) "SPILL" MEANS ANY
UNEXPECTED, UNINTENDED, ABNORMAL, OR UNAPPROVED DUMPING, LEAKAGE,
DRAINAGE, SEEPAGE, DISCHARGE OR OTHER LOSS OF PETROLEUM,
HAZARDOUS SUBSTANCES, EXTREMELY HAZARDOUS SUBSTANCES, OR
OBJECTIONABLE SUBSTANCES. THE TERM DOES NOT INCLUDE RELEASES TO
IMPERMEABLE SURFACES WHEN THE SUBSTANCE DOES NOT MIGRATE OFF THE
SURFACE OR PENETRATE THE SURFACE AND ENTER THE SOIL.
(16) "SPILL RESPONSE", FOR PURPOSES OF THIS RULE, MEANS THE FOLLOWING:
(A) THE SPILL IS CONTAINED; AND
(B) FREE MATERIAL IS REMOVED OR NEUTRALIZED.
(17) "SPILL REPORT" MEANS AN ORAL REPORT THAT INCLUDES THE FOLLOWING
INFORMATION ABOUT A SPILL, TO THE EXTENT THAT THE INFORMATION IS
KNOWN AT THE TIME OF THE REPORT:
(A) THE NAME, ADDRESS, AND TELEPHONE NUMBER OF THE PERSON
MAKING THE SPILL REPORT.
(B) THE NAME, ADDRESS, AND TELEPHONE NUMBER OF A CONTACT
PERSON IF DIFFERENT FROM CLAUSE (A).
(C) THE LOCATION OF THE SPILL.
(D) THE TIME OF THE SPILL.
(E) THE IDENTIFICATION OF THE SUBSTANCE SPILLED.
(F) THE APPROXIMATE QUANTITY OF THE SUBSTANCE THAT HAS BEEN OR
MAY FURTHER BE SPILLED.
(G) THE DURATION OF THE SPILL.
(H) THE SOURCE OF THE SPILL.
(I) NAME AND LOCATION OF THE WATERS DAMAGED.
(J) THE IDENTITY OF ANY RESPONSE ORGANIZATION RESPONDING TO THE
SPILL.
(K) WHAT MEASURES HAVE BEEN OR WILL BE UNDERTAKEN TO PERFORM
A SPILL RESPONSE.
(L) ANY OTHER INFORMATION THAT MAY BE SIGNIFICANT TO THE
RESPONSE ACTION.
(18) "WATERS", AS DEFINED IN IC 13-11-2-265, MEANS THE ACCUMULATIONS OF
WATER, SURFACE AND UNDERGROUND, NATURAL AND ARTIFICIAL, PUBLIC AND
PRIVATE, OR PARTS THEREOF, THAT ARE WHOLLY OR PARTIALLY WITHIN, FLOW
THROUGH, OR BORDER UPON THIS STATE. THE TERM DOES NOT INCLUDE ANY
PRIVATE POND OR ANY OFF-STREAM POND, RESERVOIR, OR FACILITY BUILT FOR
REDUCTION OR CONTROL OF POLLUTION OR COOLING OF WATER PRIOR TO
DISCHARGE UNLESS THE DISCHARGE FROM THE POND, RESERVOIR, OR
FACILITY CAUSES OR THREATENS TO CAUSE WATER
POLLUTION. (WATER POLLUTION CONTROL BOARD; 327 IAC 2-6.1-4; FILED FEB 25,
1997, 1:00 P.M.: 20 IR 1731; ERRATA FILED MAR 7, 1997, 2:25 P.M.: 20 IR 1738;
READOPTED FILED JAN 10, 2001, 3:23 P.M.: 24 IR 1518; READOPTED FILED NOV 21,
2007, 1:16 P.M.: 20071219-IR-327070553BFA)
327 IAC 2-6.1-5 REPORTABLE SPILLS; FACILITY
AUTHORITY: IC 13-14-8-7
AFFECTED: IC 13-11-2; IC 13-18-1; IC 13-18-3; IC 13-18-8; IC 13-18-17
SEC. 5. THE FOLLOWING SPILLS FROM A FACILITY MUST BE REPORTED:
(1) SPILLS THAT DAMAGE THE WATERS OF THE STATE SO AS TO CAUSE DEATH
OR ACUTE INJURY OR ILLNESS TO HUMANS OR ANIMALS.
(2) SPILLS FROM A FACILITY THAT HAS BEEN NOTIFIED IN WRITING BY A WATER
UTILITY THAT IT IS LOCATED IN A DELINEATED PUBLIC WATER SUPPLY
WELLHEAD PROTECTION AREA AS APPROVED BY THE DEPARTMENT UNDER 327
IAC 8-4.1 THAT ARE:
(A) SPILLS OF HAZARDOUS SUBSTANCES OR EXTREMELY HAZARDOUS
SUBSTANCES WHEN THE AMOUNT SPILLED EXCEEDS ONE HUNDRED
(100) POUNDS OR THE REPORTABLE QUANTITY, WHICHEVER IS LESS;
(B) SPILLS OF PETROLEUM WHEN THE AMOUNT SPILLED EXCEEDS
FIFTY-FIVE (55) GALLONS; OR
(C) SPILLS OF OBJECTIONABLE SUBSTANCES AS DEFINED IN SECTION 4(11)
OF THIS RULE.
(3) SPILLS THAT DAMAGE WATERS OF THE STATE AND THAT:
(A) ARE LOCATED WITHIN FIFTY (50) FEET OF A KNOWN PRIVATE DRINKING
WATER WELL LOCATED BEYOND THE FACILITY PROPERTY BOUNDARY; OR
(B) ARE LOCATED WITHIN ONE HUNDRED (100) YARDS OF:
(I) ANY HIGH QUALITY WATER DESIGNATED AS AN OUTSTANDING
STATE RESOURCE PURSUANT TO 327 IAC 2-1-2(3), EXCLUDING LAKE
MICHIGAN;
(II) ANY WATER DESIGNATED AS EXCEPTIONAL USE PURSUANT TO
327 IAC 2-13(A)(6) [SIC., 327 IAC 2-1-3(A)(6)] AND 327 IAC 2-1-11(B);
(III) ANY WATER DESIGNATED AS CAPABLE OF SUPPORTING A
SALMONID FISHERY PURSUANT TO 327 IAC 2-1-6(C)(1), EXCEPT LAKE
MICHIGAN;
OR
(IV) ANY WATER THAT IS A FISH HATCHERY, FISH AND WILDLIFE AREA,
NATURE PRESERVE, OR RECREATIONAL WATER OWNED BY THE
DEPARTMENT OF NATURAL RESOURCES OR THE FEDERAL
GOVERNMENT.
(4) FOR ANY SPILL WHICH DOES NOT MEET THE CRITERIA IN SUBDIVISIONS (1)
THROUGH (3), THE FOLLOWING MUST BE REPORTED:
(A) SPILLS TO SURFACE WATERS:
(I) SPILLS OF HAZARDOUS SUBSTANCES OR EXTREMELY HAZARDOUS
SUBSTANCES WHEN THE AMOUNT SPILLED EXCEEDS ONE HUNDRED
(100) POUNDS OR THE REPORTABLE QUANTITY, WHICHEVER IS LESS;
(II) SPILLS OF PETROLEUM OF SUCH QUANTITY AS TO CAUSE A
SHEEN UPON THE WATERS;
OR
(III) SPILLS OF OBJECTIONABLE SUBSTANCES AS DEFINED IN SECTION
4(11) OF THIS RULE.
(B) SPILLS TO SOIL BEYOND THE FACILITY BOUNDARY:
(I) SPILLS OF HAZARDOUS SUBSTANCES OR EXTREMELY HAZARDOUS
SUBSTANCES WHEN THE AMOUNT SPILLED EXCEEDS ONE HUNDRED
(100) POUNDS OR THE REPORTABLE QUANTITY, WHICHEVER IS LESS;
(II) SPILLS OF PETROLEUM WHEN THE AMOUNT SPILLED EXCEEDS
FIFTY-FIVE (55) GALLONS;
OR
(III) SPILLS OF OBJECTIONABLE SUBSTANCES AS DEFINED IN SECTION
4(11) OF THIS RULE.
(C) SPILLS TO SOIL WITHIN THE FACILITY BOUNDARY:
(I) SPILLS OF HAZARDOUS SUBSTANCES OR EXTREMELY HAZARDOUS
SUBSTANCES WHEN THE AMOUNT SPILLED EXCEEDS THE
REPORTABLE QUANTITY;
(II) SPILLS OF PETROLEUM WHEN THE SPILLED AMOUNT EXCEEDS ONE
THOUSAND (1,000) GALLONS;
OR
(III) SPILLS OF OBJECTIONABLE SUBSTANCES AS DEFINED IN SECTION
4(11) OF THIS RULE.
(5) ANY SPILL FOR WHICH A SPILL RESPONSE HAS NOT BEEN DONE.
(WATER POLLUTION CONTROL BOARD; 327 IAC 2-6.1-5; FILED FEB 25, 1997, 1:00
P.M.: 20 IR 1732; ERRATA FILED MAR 7, 1997, 2:25 P.M.: 20 IR 1738; READOPTED
FILED JAN 10, 2001, 3:23 P.M.: 24 IR 1518; READOPTED FILED NOV 21, 2007, 1:16
P.M.: 20071219-IR-327070553BFA)
327 IAC 2-6.1-6 REPORTABLE SPILLS; TRANSPORTATION
AUTHORITY: IC 13-14-8-7
AFFECTED: IC 13-11-2; IC 13-18-1; IC 13-18-3; IC 13-18-8; IC 13-18-17
SEC. 6. THE FOLLOWING SPILLS FROM A MODE OF TRANSPORTATION MUST
BE REPORTED:
(1) SPILLS THAT DAMAGE THE WATERS OF THE STATE SO AS TO CAUSE DEATH
OR ACUTE INJURY OR ILLNESS TO HUMANS OR ANIMALS.
(2) SPILLS THAT DAMAGE SURFACE WATERS.
(3) SPILLS TO SOIL:
(A) SPILLS OF HAZARDOUS SUBSTANCES OR EXTREMELY HAZARDOUS
SUBSTANCES WHEN THE AMOUNT SPILLED EXCEEDS ONE HUNDRED (100)
POUNDS OR THE REPORTABLE QUANTITY, WHICHEVER IS LESS;
(B) SPILLS OF PETROLEUM WHEN THE AMOUNT SPILLED EXCEEDS
FIFTY-FIVE (55) GALLONS;
OR
(C) SPILLS OF OBJECTIONABLE SUBSTANCES AS DEFINED IN SECTION 4(11)
OF THIS RULE.
(4) ANY SPILL FOR WHICH A SPILL RESPONSE HAS NOT BEEN DONE. (WATER
POLLUTION CONTROL BOARD; 327 IAC 2-6.1-6; FILED FEB 25, 1997, 1:00 P.M.: 20 IR
1733; READOPTED FILED JAN 10, 2001, 3:23 P.M.: 24 IR 1518; READOPTED FILED
NOV 21, 2007, 1:16 P.M.: 20071219-IR-327070553BFA)
327 IAC 2-6.1-7 REPORTABLE SPILLS; RESPONSIBILITIES
AUTHORITY: IC 13-14-8-7
AFFECTED: IC 13-11-2; IC 13-18-1; IC 13-18-3; IC 13-18-8; IC 13-18-17
SEC. 7. ANY PERSON WHO OPERATES, CONTROLS, OR MAINTAINS ANY
MODE OF TRANSPORTATION OR FACILITY FROM WHICH A SPILL OCCURS SHALL,
UPON DISCOVERY OF A REPORTABLE SPILL TO THE SOIL OR SURFACE WATERS
OF THE STATE, DO THE FOLLOWING:
(1) CONTAIN THE SPILL, IF POSSIBLE, TO PREVENT ADDITIONAL SPILLED
MATERIAL FROM ENTERING THE WATERS OF THE STATE.
(2) UNDERTAKE OR CAUSE OTHERS TO UNDERTAKE ACTIVITIES NEEDED TO
ACCOMPLISH A SPILL RESPONSE.
(3) AS SOON AS POSSIBLE, BUT WITHIN TWO (2) HOURS OF DISCOVERY,
COMMUNICATE A SPILL REPORT TO THE DEPARTMENT OF ENVIRONMENTAL
MANAGEMENT, OFFICE OF LAND QUALITY, EMERGENCY RESPONSE SECTION:
AREA CODE 1-888-233-7745 FOR IN-STATE CALLS (TOLL FREE), (317) 233-7745 FOR
OUT-OF-STATE CALLS. IF NEW OR UPDATED SPILL REPORT INFORMATION
BECOMES KNOWN THAT INDICATES A SIGNIFICANT INCREASE IN THE
LIKELIHOOD OF DAMAGE TO THE WATERS OF THE STATE, THE RESPONSIBLE
PARTY SHALL NOTIFY THE DEPARTMENT AS SOON AS POSSIBLE BUT WITHIN
TWO (2) HOURS OF THE TIME THE NEW OR UPDATED INFORMATION BECOMES
KNOWN.
(4) SUBMIT TO THE INDIANA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT,
OFFICE OF LAND QUALITY, EMERGENCY RESPONSE SECTION (MC 66-30), 2525 N.
SHADELAND AVE., SUITE 100, INDIANAPOLIS, IN 46219-1787, A WRITTEN COPY OF
THE SPILL REPORT IF REQUESTED IN WRITING BY THE DEPARTMENT.
(5) EXCEPT FROM MODES OF TRANSPORTATION OTHER THAN PIPELINES,
EXERCISE DUE DILIGENCE AND DOCUMENT ATTEMPTS TO NOTIFY THE
FOLLOWING:
(A) FOR SPILLS TO SURFACE WATER THAT CAUSE DAMAGE, THE NEAREST
AFFECTED DOWNSTREAM WATER USER LOCATED WITHIN TEN (10) MILES
OF THE SPILL AND IN THE STATE OF INDIANA;
AND
(B) FOR SPILLS TO SOIL OUTSIDE THE FACILITY BOUNDARY, THE AFFECTED
PROPERTY OWNER OR OWNERS, OPERATOR OR OPERATORS, OR OCCUPANT
OR OCCUPANTS. (WATER POLLUTION CONTROL BOARD; 327 IAC 2-6.1-7; FILED
FEB 25, 1997, 1:00 P.M.: 20 IR 1733; READOPTED FILED JAN 10, 2001, 3:23 P.M.:
24 IR 1518; ERRATA FILED FEB 6, 2006, 11:15 A.M.: 29 IR 1936; ERRATA FILED OCT
20, 2006, 10:08 A.M.: 20061101-IR-327060497ACA; READOPTED FILED NOV 21,
2007, 1:16 P.M.: 20071219-IR-327070553BFA; ERRATA FILED MAY 27, 2008, 2:06
P.M.: 20080625-IR-327080419ACA)
327 IAC 2-6.1-8 EMERGENCY SPILL RESPONSE ACTIONS
AUTHORITY: IC 13-14-8-7
AFFECTED: IC 13-11-2; IC 13-18-1; IC 13-18-3; IC 13-18-8; IC 13-18-17
SEC. 8. NOTWITHSTANDING ANY OTHER SECTION OF THIS RULE,
EMERGENCY SPILL RESPONSE ACTIONS TAKE PRECEDENCE OVER REPORTING
REQUIREMENTS, AND WHEN EMERGENCY SPILL RESPONSE ACTIVITIES RENDER
SPILL REPORTING INCONSISTENT WITH EFFECTIVE RESPONSE ACTIVITIES,
COMMUNICATION OF THE SPILL REPORT TO THE INDIANA DEPARTMENT OF
ENVIRONMENTAL MANAGEMENT MAY BE DELAYED. IN SITUATIONS WHERE THE
SPILL REPORT IS DELAYED, THE BURDEN OF PROVING THE NEED FOR THE
DELAY SHALL BE UPON THE RESPONSIBLE PERSON. (WATER POLLUTION
CONTROL BOARD; 327 IAC 2-6.1-8; FILED FEB 25, 1997, 1:00 P.M.: 20 IR 1734;
READOPTED FILED JAN 10, 2001, 3:23 P.M.: 24 IR 1518; READOPTED FILED NOV 21,
2007, 1:16 P.M.: 20071219-IR-327070553BFA)
327 IAC 2-6.1-9 COMPLIANCE CONFIRMATION
AUTHORITY: IC 13-14-8-7
AFFECTED: IC 13-11-2; IC 13-18-1; IC 13-18-3; IC 13-18-8; IC 13-18-17
SEC. 9. WHEN SPILL REPORTING AND RESPONSE, AS PROVIDED FOR IN
THIS RULE, HAS OCCURRED, THE DEPARTMENT SHALL, UPON REQUEST, ISSUE A
LETTER CONFIRMING COMPLIANCE WITH THIS RULE AND STATING THAT NO
FURTHER ACTION IS REQUIRED UNDER THIS RULE. (WATER POLLUTION
CONTROL BOARD; 327 IAC 2-6.1-9; FILED FEB 25, 1997, 1:00 P.M.: 20 IR 1734;
READOPTED FILED JAN 10, 2001, 3:23 P.M.: 24 IR 1518; READOPTED FILED NOV 21,
2007, 1:16 P.M.: 20071219-IR-327070553BFA)
C104STORMWATER POLLUTION PREVENTION PLAN SPECSW190582-C102 swppp specSEASONAL SOIL PROTECTION CHARTSOILS MAP
SOILS TYPE LEGEND
UbaA URBAN LAND - BROOKSTON COMPLEX, 0 TO 2
PERCENT SLOPES
UkbB2 URBAN LAND - MIAMI SILT LOAM COMPLEX, 2 TO 6
PERCENT SLOPES ERODED
NO SCALE
PERMANENT
SEEDING
SODDING
MULCHING
METHOD
STABILIZATION
SOIL
SEEDING
DORMANT
SEEDING
TEMPORARY
A = KENTUCKY BLUEGRASS* 40 LBS/ACRE; CREEPING RED FESCUE 40 LBS/ACRE;
PLUS 2 TONS STRAW MULCH/ACRE, OR ADD ANNUAL RYEGRASS 20 LBS/ACRE.
B = KENTUCKY BLUEGRASS* 60 LBS/ACRE; CREEPING RED FESCUE 60 LBS/ACRE;
PLUS 2 TONS STRAW MULCH/ACRE, OR ADD ANNUAL RYEGRASS 30 LBS/ACRE.
C = SPRING OATS 3 BUSHEL/ACRE.
D = WHEAT OR RYE 2 BUSHEL/ACRE.
E = ANNUAL RYEGRASS 40 LBS/ACRE.
F = SOD (BLEND 3 IMPROVED VARIETIES).
G = STRAW MULCH 2 TONS/ACRE.
*/I/* IRRIGATION NEEDED DURING JUNE, JULY, AND/OR SEPTEMBER.
** IRRIGATION NEEDED FOR 2 TO 3 WEEKS AFTER APPLYING SOD.
*KENTUCKY BLUEGRASS BLEND OF 3 IMPROVED VARIETIES.PROJECT LOCATION PROJECT LOCATION
AREA MAP REVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, Indiana W19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
EXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJSENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
CARMEL DR.
116th ST.RANGELINE RD.MECHANICAL WATER QUALITY UNIT:
THE MECHANICAL WATER QUALITY UNIT PROVIDES A HIGHLY EFFECTIVE MEANS FOR THE REMOVAL OF SEDIMENT, FLOATING DEBRIS AND FREE-OIL. SWIRL
TECHNOLOGY, OR VORTEX SEPARATION, IS A PROVEN FORM OF TREATMENT UTILIZED IN THE STORMWATER INDUSTRY TO ACCELERATE GRAVITATIONAL SEPARATION.
THE WQU PROVIDES TREATMENT FOR MOST CONTAMINATED FIRST FLUSH, WHILE THE CLEANER PEAK STORM FLOW IS DIVERTED AND CHANNELED
THROUGH THE MAIN CONVEYANCE PIPE. A COMBINATION OF GRAVITATIONAL AND HYDRODYNAMIC DRAG FORCES ENCOURAGES THE SOLIDS TO DROP
OUT OF THE FLOW AND MIGRATE TO THE CENTER OF THE CHAMBER WHERE VELOCITIES ARE THE LOWEST.
CATCH BASINS:
CATCH BASIN/INLET CLEANING AND REPAIR HAS TRADITIONALLY BEEN PERFORMED TO RESPOND TO LOCALIZED FLOODING PROBLEMS IN STREETS.
CATCH BASINS ARE INLETS AT THE CURB WITH A SMALL TRAP (USUALLY SIX INCHES TO ONE FOOT DEEP) BELOW THE SEWER PIPE. THESE DEVICES HELP
TO CLEAN STORM WATER BECAUSE PARTICLES IN STREET RUNOFF SETTLE INTO THE TRAP BEFORE THE WATER ENTERS THE STORM SEWERS. CATCH
BASINS REQUIRE REGULAR CLEANING OF THE SEDIMENT TRAP TO BE. THE INLETS DO NOT TRAP SEDIMENTS AND DON'T NEED CLEANING UNLESS THEY
ARE PLUGGED. CLEANING FOR EITHER CATCH BASINS OR INLETS CAN BE DONE BY HAND (E.G., WITH A CLAMSHELL OR SHOVEL) OR WITH A VACUUM
TRUCK.
CONVEYANCE STORM PIPES:
A GOOD RULE OF THUMB IS TO CONDUCT INSPECTION OF STORM DRAIN INLETS, DITCHES, CHANNELS, PONDS AND OTHER TREATMENT FACILITIES AT
LEAST ONCE A YEAR, PRIOR TO THE BEGINNING OF THE RAINY SEASON. COMPLETE INSPECTIONS EARLY ENOUGH SO THAT REPAIRS CAN BE MADE
DURING DRY WEATHER. CATCH BASINS SHOULD BE INSPECTED AT LEAST ONCE EVERY SIX MONTHS. SOME STORM WATER TREATMENT DEVICES, SUCH AS
OIL/WATER SEPARATORS, MAY REQUIRE MORE FREQUENT INSPECTION. FOR THESE, CHECK THE MANUFACTURER'S SPECIFICATION OR OTHER DESIGN
GUIDANCE HANDBOOKS. SEWER PIPES AND CULVERTS SHOULD BE INSPECTED EVERY THREE TO FIVE YEARS, OR IN RESPONSE TO A REPORTED
PROBLEM. MOST AGENCIES INSPECT THEIR SEWER PIPES SIX INCHES OR LARGER WITH A TV CAMERA, AND PIPES 36 INCHES OR LARGER WITH A
WALK-THROUGH INSPECTION. ALL OTHER PARTS OF THE SYSTEM ARE INSPECTED VISUALLY.
LOOK FOR EXCESSIVE SILT BUILD-UP, EROSION, UNUSUAL ALGAL GROWTH, CRACKED OR COLLAPSED PIPES, MISALIGNED JOINTS, AND OTHER SIGNS OF
PROBLEMS SUCH AS A SHEEN ON THE WATER SURFACE, DISCOLORED WATER, OR AN UNPLEASANT ODOR. CHECK WITH PRODUCT MANUFACTURERS OR
STORM WATER HANDBOOKS FOR ADVICE ON WHAT TO LOOK FOR WHEN INSPECTING MORE SOPHISTICATED TREATMENT DEVICES SUCH AS FLOW
SPLITTERS AND DIVERTERS. WHEN A PROBLEM IS NOTED, TAKE STEPS TO CORRECT THE PROBLEM, OR ROUTE THIS INFORMATION IMMEDIATELY TO THE
APPROPRIATE INDIVIDUAL(S) IN YOUR ORGANIZATION WHO CAN RESPOND. IF NEEDED, DEVELOP A GOOD RESPONSE PLAN TO ENSURE QUICK FOLLOW-UP
IN THE FUTURE.
DRY DETENTION BASIN:
DETENTION STORAGE LOCATED IN DRY DETENTION BASIN DESIGN TO PROVIDE STORAGE OF STORMWATER RUNOFF DURING RAIN EVENTS AND REDUCE
PEAK RUNOFF RATES FROM THE SITE. SYSTEM IS DESIGNED TO BE DRY AND TYPICALLY REQUIRE A WATER QUALITY FEATURE UPSTREAM OF THE
SYSTEM.
SWPPP FOR CONSTRUCTION SITES:
1. 14 DIGIT WATERSHED HYDROLOGIC UNIT CODE: 05120201090040
2. NAME OF ALL RECEIVING WATERS IF THE DISCHARGE IS TO A MUNICIPAL SEPARATE STORM SEWER, IDENTIFY THE ULTIMATE RECEIVING
WATER: WHITE RIVER - CARMEL CREEK
3. ESTIMATE OF PEAK DISCHARGE FOR POST CONSTRUCTION CONDITIONS (10-YEAR): 27.07 cfs
4. LOCATIONS OF SPECIFIC POINTS WHERE STORMWATER DISCHARGE WILL LEAVE THE SITE: STRUCTURE AT THE SW CORNER OF THE SITE
INTO STORM SEWER.
5. LOCATIONS WHERE STORMWATER MAY BE DIRECTLY DISCHARGED INTO GROUNDWATER, SUCH AS ABANDONED WELLS OR SINKHOLES:
N/A
6. SOILS MAP OF THE PREDOMINANT SOIL TYPES INCLUDING:
a. SOIL LEGEND WITH DESCRIPTIONS OF EACH SOIL TYPE: THIS SHEET
b. BRIEF DESCRIPTION OF HOW THE SITE HAS ACCOMMODATED THE EXISTING SOIL LIMITATIONS
7. DESCRIPTION OF POTENTIAL POLLUTANT SOURCES ASSOCIATED WITH THE CONSTRUCTION ACTIVITIES: POTENTIAL POLLUTANTS FROM
CONSTRUCTION ACTIVITY SUCH AS ASPHALT FROM PAVING; CONCRETE FROM CURBING, SIDEWALKS, OIL, GREASE, ANTIFREEZE,
GASOLINE AND DIESEL FUEL FROM CONSTRUCTION EQUIPMENT; SOIL EROSION; FERTILIZER AND PESTICIDES FROM LANDSCAPING AND
TRASH SHOULD BE PROPERLY ATTENDED TO TO REDUCE THE CONTAMINANTS FROM ENTERING THE STORM SYSTEM. TRASH SHOULD BE
CLEANED UP TO REDUCE CLOGGING OF STORM SYSTEMS AND REDUCE POTENTIAL BACTERIA AND/OR OTHER BIOLOGICAL AGENTS FROM
ENTERING IN THE STORM SYSTEM.
8. TEMPORARY AND PERMANENT STORMWATER QUALITY MEASURES:
TEMPORARY WATER QUALITY MEASURES INCLUDE INLET PROECTION MEASURES AND SILT FENCING. PERMANENT WATER QUALITY
MEASURES INCLUDE MECHANICAL WATER QUALITY UNIT.
9. GENERAL CONSTRUCTION SEQUENCE:
a. A PRE-CONSTRUCTION MEETING WITH THE CITY OF CARMEL IS REQUIRED PRIOR TO THE COMMENCEMENT OF ANY EARTHWORK.
ADDITIONALLY, IDEM IS REQUIRED TO BE CONTACTED AT LEAST 48 HOURS PRIOR TO CONSTRUCTION.
b. CONSTRUCTION ENTRANCE - REMOVE EXISTING ASPHALT AND STRIP TOPSOIL AND PLACE STONE AT ACCESS POINT ALONG WEST
CARMEL DRIVE.
c. INSTALL SILT FENCING AND ALL OTHER EROSION CONTROL MEASURES PRIOR TO ANY EARTH MOVING.
d. EARTHWORK - STRIP TOPSOIL, BEGIN ROUGH GRADING AND PREPARE BUILDING PAD AND ROUGH GRADE.
e. SANITARY SEWER - INSTALL SANITARY SEWER SYSTEM
f. STORM SEWER - INSTALL STORM SEWER SYSTEM AND CORRESPONDING INLET PROTECTION
g. UTILITIES - COORDINATE INSTALLATION OF ALL UTILITIES.
h. FINISH GRADING AND PERMANENT EROSION CONTROL - FINISH GRADE AND PERMANENTLY SEED ALL PROPERTY PERIMETER
AREAS.
i. PAVEMENT - INSTALL STONE, BASE COURSES AND FINISHED GRADES FOR ENTRY DRIVE.
j. CLEANUP - CONTRACTOR SHALL SPOIL ALL EXCESS MATERIALS, REGRADE AND STABILIZE ALL AREAS DISTURBED BY UTILITY
INSTALLATIONS AND RESEED.
k. FINAL LANDSCAPING - INSTALL FINAL LANDSCAPING.
10. LOCATION OF PROPOSED SOIL STOCKPILES, BORROW, AND/OR DISPOSAL AREAS: STOCKPILES WILL BE GENERALLY ON THE SOUTH
PORTION OF THE SITE SINCE MOST OF THE SITE WILL BE IN CUT.
11. TEMPORARY AND PERMANENT SURFACE STABILIZATION METHODS APPROPRIATE FOR EACH SEASON.
PROVIDE APPLICATION RATES FOR SOIL AMENDMENTS AND SEED MIXTURES, AS WELL AS, THE TYPE AND APPLICATION RATE FOR MULCH:
SEEDING CHART SHOWN ON THIS SHEET. SEEDING DETAILS SHOWN ON C103.
12. EROSION AND SEDIMENT CONTROL SPECIFICATIONS FOR INDIVIDUAL BUILDING LOTS: EROSION CONTROL SPECS ARE ON SHEET C102,
C103, C104, C105, C106, C900, C901 AND C902.
13. MATERIAL HANDLING, STORAGE, AND SPILL PREVENTION PLAN:
a. LIST OF EXPECTED MATERIALS THAT MAY BE PRESENT ON THE SITE DURING CONSTRUCTION OPERATIONS: ASPHALT, CONCRETE,
OIL, GREASE, ANTIFREEZE, GASOLINE AND DIESEL FUEL, SOIL, FERTILIZER, PESTICIDES, STEEL, WOOD.
b. WRITTEN DESCRIPTION OF HOW THESE MATERIALS WILL BE HANDLED TO MINIMIZE THE POTENTIAL OF ENTERING THE STORM
SEWER SYSTEM: ALL MATERIALS WILL BE HANDLED TO MINIMIZE RISK OF SPILLS AND POLLUTION.
c. PROCEDURES FOR THE CONTRACTOR TO TAKE IF ANY SPILLS OCCUR DURING CONSTRUCTION: IF THERE IS A SPILL FROM ONE OF
THESE, IMMEDIATE CLEANUP SHOULD OCCUR; SOIL EROSION; FERTILIZER AND PESTICIDES FROM LANDSCAPING AND TRASH
SHOULD BE PROPERLY ATTENDED TO TO REDUCE THE CONTAMINANTS FROM ENTERING THE STORM SYSTEM. TRASH SHOULD BE
CLEANED UP TO REDUCE CLOGGING OF STORM SYSTEMS AND REDUCE POTENTIAL BACTERIA AND/OR OTHER BIOLOGICAL AGENTS
FROM ENTERING IN THE STORM SYSTEM, AND SHALL MEET THE REQUIREMENTS OF IAC 2-6.1. FOLLOW MATERIAL SAFETY DATA
SHEET (MSDS) GUIDELINES FOR CONTAMINANTS PRESENT ON SITE.
14. CONTACT INFORMATION FOR THE TRAINED INDIVIDUAL RESPONSIBLE FOR STORMWATER POLLUTION PREVENTION FOR THE PROJECT
SITE
a. NAME: FRED PARKER, CPESC
b. ADDRESS: 10505 N. COLLEGE AVE., INDIANAPOLIS, IN 46280
c. TELEPHONE NUMBER: (317) 846-6611
d. E-MAIL ADDRESS: PARKERF@WEIHE.NET
e. LIST OF QUALIFICATIONS: CPESC
15. CURRENT REVISION DATE ON ALL SHEETS: REFER TO TITLE BLOCK ON EACH SHEET
SWPPP FOR POST-CONSTRUCTION:
1. DESCRIPTION OF POTENTIAL POLLUTANT SOURCES ASSOCIATED WITH THE PROPOSED LAND USE: OIL, GREASE, ANTIFREEZE, GASOLINE
AND DIESEL FUEL, SOIL, FERTILIZER, PESTICIDES.
2. POST-CONSTRUCTION STORMWATER QUALITY MEASURES: TEMPORARY WATER QUALITY MEASURES INCLUDE INLET PROTECTION
MEASURES AND SILT FENCING. PERMANENT WATER QUALITY MEASURES INCLUDE MECHANICAL WATER QUALITY UNIT.
3. SEQUENCE DESCRIBING STORMWATER QUALITY MEASURE IMPLEMENTATION DESCRIPTION OF WHEN THE PROPOSED POST
CONSTRUCTION STORMWATER QUALITY MEASURES WILL BE INSTALLED IN RELATION TO THE GENERAL CONSTRUCTION SEQUENCE:
INLET PROTECTION WILL BE INSTALLED DURING STORM SEWER INSTALLATION. A HYDRO INTERNATIONAL 8 FT. FIRST DEFENSE HIGH
CAPACITY MECHANICAL WATER QUALITY UNIT AND DRY BASIN WITH NATIVE SEED PLANTINGS WILL BE INSTALLED DURING STORM SEWER
INSTALLATION.
4. STORMWATER QUALITY MEASURES TO BE IMPLEMENTED TO PREVENT OR MINIMIZE ADVERSE IMPACTS TO STREAM AND RIPARIAN
HABITATS: PERMANENT WATER QUALITY MEASURES INCLUDE MECHANICAL WATER QUALITY UNIT.
5. AN OPERATION AND MAINTENANCE MANUAL FOR ALL POST-CONSTRUCTION STORMWATER QUALITY MEASURES: HAS BEEN SUBMITTED
ALONG WITH THIS REPORT.
07/14/21
SEDIMENTATION/SILT FENCE
INSTALLATION
PREFABRICATED SILT FENCE
1. LAY OUT THE LOCATION OF THE FENCE SO THAT IT IS PARALLEL TO THE CONTOUR OF THE SLOPE AND AT LEAST 10 FEET BEYOND THE TOE OF THE SLOPE TO PROVIDE A SEDIMENT
STORAGE AREA. TURN THE ENDS OF THE FENCE UP SLOPE SUCH THAT THE POINT OF CONTACT BETWEEN THE GROUND AND THE BOTTOM OF THE FENCE END TERMINATES AT A HIGHER
ELEVATION THAN THE TOP OF THE FENCE AT ITS LOWEST POINT.
2. EXCAVATE AN EIGHT-INCH DEEP BY FOUR-INCH WIDE TRENCH ALONG THE ENTIRE LENGTH OF THE FENCE LINE. INSTALLATION BY PLOWING IS ALSO ACCEPTABLE.
3. INSTALL THE SILT FENCE WITH THE FILTER FABRIC LOCATED ON THE UP-SLOPE SIDE OF THE EXCAVATED TRENCH AND THE SUPPORT POSTS ON THE DOWN-SLOPE SIDE OF THE TRENCH.
4. DRIVE THE SUPPORT POSTS AT LEAST 18 INCHES INTO THE GROUND, TIGHTLY STRETCHING THE FABRIC BETWEEN THE POSTS AS EACH IS DRIVEN INTO THE SOIL. MINIMUM OF 12 INCHES
OF THE FILTER FABRIC SHOULD EXTEND INTO THE TRENCH.
5. LAY THE LOWER FOUR INCHES OF FILTER FABRIC ON THE BOTTOM OF THE TRENCH AND EXTEND IT TOWARD THE UP-SLOPE SIDE OF THE TRENCH.
6. BACKFILL THE TRENCH WITH SOIL MATERIAL AND COMPACT IT IN PLACE.
NOTE: IF THE SILT FENCE IS BEING CONSTRUCTED ON-SITE, ATTACH THE FILTER FABRIC TO THE SUPPORT POSTS AND ATTACH WOODEN LATHE TO SECURE THE FABRIC TO THE POSTS.
ALLOW FOR AT LEAST 12 INCHES OF FABRIC BELOW GROUND LEVEL. COMPLETE THE SILT FENCE INSTALLATION, FOLLOWING STEPS 1 THROUGH 6 ABOVE.
MAINTENANCE
_ INSPECT WITHIN 24 HOURS OF A RAIN EVENT AND AT LEAST ONCE EVERY SEVEN CALENDAR DAYS.
_ IF FENCE FABRIC TEARS, STARTS TO DECOMPOSE, OR IN ANY WAY BECOMES INEFFECTIVE, REPLACE THE AFFECTED PORTION IMMEDIATELY. NOTE: ALL REPAIRS SHOULD MEET
SPECIFICATIONS AS OUTLINED WITHIN THIS MEASURE.
_ REMOVE DEPOSITED SEDIMENT WHEN IT IS CAUSING THE FILTER FABRIC TO BULGE OR WHEN IT REACHES ONE-HALF THE HEIGHT OF THE FENCE AT ITS LOWEST POINT. WHEN
CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE THE FENCE AND SEDIMENT DEPOSITS, GRADE THE SITE TO BLEND WITH THE SURROUNDING AREA, AND STABILIZE.
REFERENCE IN CHAPTER 7 PAGES 215-221 IN THE INDIANA STORM WATER QUALITY MANUAL
2-WOOD POST/STAKES WRAPPED
WITH SILT FENCE AND ROTATED AT
LEAST ONE FULL TURN TO SECURE
SILT FENCE END IN PLACE
SILT FENCE
SILT FENCE
POST
TO JOIN TO
ENDS OF TWO
FENCES.
EMBEDDED SILT FENCE MATERIAL MIN. 8"
INTO GROUND W/ 4" LAID ALONG BOTTOM OF
TRENCH. SOIL SLICING IN ACCORDANCE
WITH ASTM D 6462 8.2.2 IS ALSO
ACCEPTABLE.
GEOTEXTILE FABRIC LAID ON
DOWN SLOPE SIDE AND
BOTTOM OF TRENCH
8"X4" TRENCH TO BE BACKFILLED
AND COMPACTED
WOVEN FILTER FABRIC SILT
FENCE MATERIAL COVER
POST 2"X2" WOOD OR 1.33
LBS/FOOT STEEL 6' MAX.
SPACING
EMBEDDED SILT FENCE MATERIAL MIN. 8"
INTO GROUND W/ 4" LAID ALONG BOTTOM OF
TRENCH. SOIL SLICING IN ACCORDANCE WITH
ASTM D 6462 8.2.2 IS ALSO ACCEPTABLE.
GEOTEXTILE FABRIC LAID
ON DOWN SLOPE SIDE AND
BOTTOM OF TRENCH
POST 2"X2" WOOD OR 1.33 LBS/FOOT
STEEL 8' MAX. SPACING
WIRE FENCE 14 GUAGE (MIN)-6" MESH
REQ'D. IN SWALES OR AREAS OF
CONCENTRATED FLOW
NONWOVEN FILTER FABRIC -
SECURE TO POSTS WITH 2" LATH
2-WOOD POST/STAKES WRAPPED
WITH SILT FENCE AND ROTATED
AT LEAST TWO FULL TURNS TO
PROVIDE A SECURE CONNECTION
WOOD OR METAL
STAKES TO SECURE
THE STRAW BALES
(TWO PER BALE)
10 MIL. PLASTIC LINING
STRAW BALE (TYP)
SECTION LINE
STRAW BALE (TYP)
BINDING WIRE
WOOD OR METAL
STAKES (TYP) - 2 PER
BALENATIVE MATERIAL (OPTIONAL)
POLYETHYLENE LINING 10
MIL. EXTENDING OVER
BALES
(NO SCALE)TYPE "ABOVE GRADE
W/ STRAW BALES"4"WOOD OR METAL
STAKES TO SECURE
THE STRAW BALES
(TWO PER BALE)
POLYETHYLENE LINING 10
MIL. EXTENDING OVER
BALES
METAL PINS OR STAPLES
TO SECURE THE
POLYETHYLENE LINING TO
THE STRAW BALES
METAL PINS OR STAPLES
TO SECURE THE
POLYETHYLENE LINING
TO THE STRAW BALES
CONCRETE
WASHOUT
WOOD POST 3"x3"x8'
BLACK LETTER 6" HEIGHT
3/8" TREATED
PLYWOOD 48"x24"
PAINTED WHITE
0.5" LAG SCREWS
INSTALLATION
1. UTILIZE AND FOLLOW THE DESIGN IN THE STORM WATER POLLUTION PREVENTION
PLAN TO INSTALL THE SYSTEM.
2. DEPENDENT UPON THE TYPE OF SYSTEM, EITHER EXCAVATE THE PIT OR INSTALL
THE CONTAINMENT SYSTEM.
3. A BASE SHALL BE CONSTRUCTED AND PREPARED THAT IS FREE OF ROCKS AND
OTHER DEBRIS THAT MAY CAUSE TEARS OR PUNCTURES IN THE POLYETHYLENE
LINING.
4. INSTALL THE POLYETHYLENE LINING. FOR EXCAVATED SYSTEMS, THE LINING
SHOULD EXTEND OVER THE ENTIRE EXCAVATION. THE LINING FOR BERMED
SYSTEMS SHOULD BE INSTALLED OVER THE POOLING AREA WITH ENOUGH MATERIAL
TO EXTEND THE LINING OVER THE BERM OR CONTAINMENT SYSTEM. THE LINING
SHOULD BE SECURED WITH PINS, STAPLES, OR OTHER FASTENERS.
5. PLACE FLAGS, SAFETY FENCING, OR EQUIVALENT TO PROVIDE A BARRIER TO
CONSTRUCTION EQUIPMENT AND OTHER TRAFFIC.
6. PLACE A NON-COLLAPSING, NON-WATER HOLDING COVER OVER THE WASHOUT
FACILITY PRIOR TO A PREDICTED RAINFALL EVENT TO PREVENT ACCUMULATION OF
WATER AND POSSIBLE OVERFLOW OF THE SYSTEM (OPTIONAL).
7. INSTALL SIGNAGE THAT IDENTIFIES CONCRETE WASHOUT AREAS.
8. POST SIGNS DIRECTING CONTRACTORS AND SUPPLIERS TO DESIGNATED
LOCATIONS.
9. WHERE NECESSARY, PROVIDE STABLE INGRESS AND EGRESS APPROACH PAD FOR
CONCRETE WASHOUT SYSTEMS.
10. USE A 10 MIL. POLYETHYLENE LINED DUMPSTER AS AN ALTERNATE.
C105STORMWATER POLLUTION PREVENTION PLAN DETAILSW190582-C103 swppp det3' 3'PLAN
1. ACTUAL LAYOUT DETERMINED IN
FIELD.
2. THE CONCRETE WASHOUT SIGN
SHALL BE INSTALLED WITHIN
30FT. OF THE TEMP. CONCRETE
WASHOUT FACILITY.
SECTION
CONCRETE WASHOUT8"8"8"X4" TRENCH TO BE
BACKFILLED AND COMPACTED
POSTS: STEEL T OR U TYPE, OR 2"X2" HARD WOOD POST
FENCE: WOVEN WIRE, 14-1/2 GA., 6" MAX. MESH OPENING
FABRIC: IN ACCORDANCE WITH ASTM D 6461 LATEST EDITION.
LOAD SLOPE
LESS THAN 2%
2 TO 5%
5 TO 10%
10 TO 20%
MORE THAN 20%
MAX. DISTANCE ABOVE FENCE
100 FT.
75 FT.
50 FT.
25 FT.
15 FT.
WITHOUT WIRE SUPPORT WITH WIRE SUPPORT
(NO SCALE)
FLOW
FINISH GRADE
UNDISTURBED
GROUND
FLOW
FINISH GRADE
UNDISTURBED
GROUND
NOTES:
1. THE SWPPP INFORMATION SIGN MUST BE LOCATED NEAR THE
CONSTRUCTION EXIT OF THE SITE, SUCH THAT IT IS ACCESSIBLE
AND VIEWABLE BY THE GENERAL PUBLIC, BUT NOT OBSTRUCTING
VIEWS AS TO CAUSE A SAFETY HAZARD.
2. ALL POSTED DOCUMENTS MUST BE MAINTAINED IN A CLEARLY
READABLE CONDITION AT ALL TIMES THROUGHOUT
CONSTRUCTION AND UNTIL THE NOTICE-OF-TERMINATION (NOT) IS
FILED FOR THE PERMIT.
3. CONTRACTOR SHALL POST OTHER STORM WATER AND/OR
EROSION AND SEDIMENT CONTROL RELATED PERMITS ON THE
SIGN AS REQUIRED BY THE GOVERNING AGENCY.
4. SIGN SHALL BE LOCATED OUTSIDE OF PUBLIC RIGHT-OF-WAY AND
EASEMENTS UNLESS APPROVED BY THE GOVERNING AGENCY.
5. CONTRACTOR IS RESPONSIBLE FOR ENSURING STABILITY OF THE
SWPPP INFORMATION SIGN.
SWPPP INFORMATION SIGN
COPY
OF
NOI
COPY OF
IDEM
NOTICE OF
SUFFICIENCY
SWPPP INFORMATION
DETAILED DESCRIPTION OF THE LOCATION OF THE
SWPPP DOCUMENTATION (BINDER AND SITE MAPS)
ON THE SITE.
SIGN TO BE CONSTRUCTED OF A
RIGID MATERIAL, SUCH AS
PLYWOOD OR OUTDOOR SIGN
BOARD. SIGN MUST BE
CONSTRUCTED IN A MANNER TO
PROTECT DOCUMENTS FROM
DAMAGE DUE TO WEATHER (WIND,
SUN, MOISTURE, ETC.).
"SWPPP INFORMATION" MUST BE
DISPLAYED PROMINENTLY ACROSS
THE TOP OF THE SIGN, AS SHOWN IN
THE DETAIL. 3" MIN. 3" MIN.COPY
OF
DRAINAGE
APPROVAL
LETTER
COPY
OF
CONSTRUCTION
SITE
NOTICE AS
APPLICABLE
COPY
OF
CONSTRUCTION
SITE
NOTICE AS
APPLICABLE
COPY
OF
CONSTRUCTION
SITE
NOTICE AS
APPLICABLE
(NO SCALE)
ALTERNATE
CONTRACTOR MAY USE A LINED (10 MIL. POLYETHYLENE) DUMPSTER FOR CONCRETE WASHOUT.
NOTE: DUMPSTER IS TO BE USED FOR CONCRETE WASHOUT ONLY. NO CONSTRUCTION WASTE
OR DEBRIS SHALL BE ALLOWED TO PREVENT TEARING OF THE LINER.
SHEET 1 OF 1
DRAWN
CHECKED
QA
MFG
APPROVED
DWG NOSIZE
SCALE
REV
REPLACEABLE SEDIMENT BAGS
WITH GEOTEXTILE FILTER FABRIC
LIFT HANDLES
STAINLESS
STEEL
CLAMPING
BAND
REAR CURB GUARD FLAPWITH MAGNETIC TIE-DOWNS
ALL PRODUCTS MANUFACTURED
BY INLET & PIPE PROTECTION, INC
DISTRIBUTED BY ADS
WWW.INLETFILTERS.COM
(866) 287-8655 PH
(630) 355-3477 FX
INFO@INLETFILTERS.COM
INSTALLATION:
1.
2.
REMOVE GRATE
DROP FLEXSTORM INLET FILTER ONTO
LOAD BEARING LIP OF CASTING OR
CONCRETE STRUCTURE
3. REPLACE GRATE
STANDARD 2"
OVERFLOW
AREA 11 GAUGE STEEL SUSPENSION SYSTEM
IPP TEMPORARY SEED
TABLE 1. TEMPORARY SEEDING SPECIFICATIONS
AUG. 1 - SEPT. 1
GERMAN MILLET
WHEAT OR RYE 150 LBS. 1 TO 1½ INCHES SEPT. 15 - OCT. 30
SPRING OATS 100 LBS. 1 INCH MARCH 1 - APRIL 15
ANNUAL RYEGRASS 40 LBS. ¼ INCH MARCH 1 - MAY 1
40 LBS. 1 TO 2 INCHES MAY 1 - JUNE 1
SUDANGRASS 35 LBS. MAY 1 - JULY 30
BUCKWHEAT 60 LBS. APRIL 15 - JUNE 1
CORN (BROADCAST) 300 LBS. MAY 11 - AUG. 10
SORGHUM 35 LBS. MAY 1 - JULY 15
1 TO 2 INCHES
1 TO 2 INCHES
1 TO 2 INCHES
1 TO 2 INCHES
1. PERENNIAL SPECIES MAY BE USED AS A TEMPORARY COVER, ESPECIALLY IF THE AREA TO BE
SEEDED WILL REMAIN IDLE FOR MORE THAN ONE YEAR.
2. SEEDING DONE OUTSIDE THE OPTIMUM SEEDING DATES INCREASES THE CHANCES OF SEEDING FAILURE. DATES
MAY BE EXTENDED OR SHORTENED BASED ON THE LOCATION OF THE PROJECT
SITE WITHIN THE STATE.
NOTES
1. MULCH ALONE IS AN ACCEPTABLE TEMPORARY COVER AND MAY BE USED IN LIEU OF TEMPORARY SEEDING, PROVIDED THAT IT IS
APPROPRIATELY ANCHORED.
2. A HIGH POTENTIAL FOR FERTILIZER, SEED, AND MULCH TO WASH EXISTS ON STEEP BANKS, CUTS, AND IN CHANNELS AND AREAS
OF CONCENTRATED FLOW.
SEEDBED PREPARATION
1. TEST SOIL TO DETERMINE PH AND NUTRIENT LEVELS.
2. APPLY SOIL AMENDMENTS AS RECOMMENDED BY THE SOIL TEST. IF TESTING IS NOT DONE, APPLY 400 TO 600 POUNDS PER ACRE
OF 12-12-12 ANALYSIS FERTILIZER, OR EQUIVALENT.
3. WORK THE SOIL AMENDMENTS INTO THE UPPER TWO TO FOUR INCHES OF THE SOIL WITH
A DISK OR RAKE OPERATED ACROSS THE SLOPE.
SEEDING
1. SELECT A SEED SPECIES OR AN APPROPRIATE SEED MIXTURE AND APPLICATION RATE FROM TABLE 1.
2. APPLY SEED UNIFORMLY WITH A DRILL OR CULTIPACKER SEEDER OR BY BROADCASTING. PLANT OR COVER SEED TO THE DEPTH
SHOWN IN TABLE 1.
NOTES
1. IF DRILLING OR BROADCASTING THE SEED, ENSURE GOOD SEED-TO-SOIL CONTACT BY FIRMING THE SEEDBED WITH A ROLLER OR
CULTIPACKER AFTER COMPLETING SEEDING OPERATIONS.
2. DAILY SEEDING WHEN THE SOIL IS MOIST IS USUALLY MOST EFFECTIVE.
3. IF SEEDING IS DONE WITH A HYDROSEEDER, FERTILIZER AND MULCH CAN BE APPLIED WITH THE SEED IN A SLURRY MIXTURE.
3. APPLY MULCH AND ANCHOR IT IN PLACE.
MAINTENANCE
1. INSPECT WITHIN 24 HOURS OF EACH RAIN EVENT AND AT LEAST ONCE EVERY SEVEN CALENDAR DAYS.
2. CHECK FOR EROSION OR MOVEMENT OF MULCH AND REPAIR IMMEDIATELY.
3. MONITOR FOR EROSION DAMAGE AND ADEQUATE COVER (80 PERCENT DENSITY); RESEED, FERTILIZE, AND APPLY 4. MULCH
WHERE NECESSARY.
4. IF NITROGEN DEFICIENCY IS APPARENT, TOP-DRESS FALL SEEDED WHEAT OR RYE SEEDING WITH 50 POUNDS PER ACRE OF
NITROGEN IN FEBRUARY OR MARCH.
REFERENCE IN CHAPTER 7 PAGES 31-33 IN THE INDIANA STORM WATER QUALITY MANUAL
TEMPORARY SEED
TABLE 1. TEMPORARY SEEDING SPECIFICATIONS
SEED SPECIES1 RATE PER ACRE PLANTING DEPTH OPTIMUM DATES2
MAINTENANCE
1. INSPECT DAILY AND AFTER EACH STORM EVENT FOR LEAKS, SPILLS, TRACKING OF SOIL BY EQUIPMENT, AND THE
POLYETHYLENE LINING FOR FAILURE.
2. ONCE CONCRETE WASTES HARDEN, REMOVE AND DISPOSE OF THE MATERIAL. EXCESS CONCRETE SHOULD BE REMOVED
WHEN THE WASHOUT SYSTEM REACHES 50 PERCENT OF THE DESIGN CAPACITY AND SHOULD NOT BE USED UNTIL
PROPERLY CLEANED OUT.
3. PLASTIC LINER SHOULD BE REPLACED AFTER EVERY CLEANING, THE REMOVAL OF MATERIAL USUALLY DAMAGES IT.
4. REPAIR OR ENLARGE AS NECESSARY TO MAINTAIN CAPACITY FOR CONCRETE WASTE.
5. IF LIQUIDS DO NOT EVAPORATE IT MAY BE NECESSARY TO VACUUM OR REMOVE THE LIQUIDS AND DISPOSE OF THEM IN
AN ACCEPTABLE METHOD.
6. WHEN CONCRETE WASHOUT SYSTEMS ARE NO LONGER REQUIRED THEY SHALL BE CLOSED AND HOLES, DEPRESSIONS
AND OTHER DISTURBANCES ASSOCIATED WITH THE SYSTEM SHOULD BE BACKFILLED, GRADED, AND STABILIZED.REVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, Indiana W19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
EXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJSE N GI N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
INSTALLATION
1. REMOVE ALL VEGETATION AND OTHER OBJECTIONABLE MATERIAL FROM THE FOUNDATION AREA.
2. GRADE THE FOUNDATION AND CROWN FOR POSITIVE DRAINAGE.
3. INSTALL A CULVERT PIPE UNDER THE PAD IF NEEDED TO MAINTAIN PROPER PUBLIC ROAD DRAINAGE.
4. IF WET CONDITIONS ARE ANTICIPATED, PLACE GEOTEXTILE FABRIC ON THE GRADED FOUNDATION TO
IMPROVE STABILITY.
5. PLACE AGGREGATE (INDOT CA NO. 2) TO THE DIMENSIONS AND GRADE SHOWN IN THE CONSTRUCTION
PLANS, LEAVING THE SURFACE SMOOTH AND SLOPED FOR DRAINAGE.
6. TOP-DRESS THE DRIVE WITH WASHED AGGREGATE (INDOT CA NO.2).
7. WHERE POSSIBLE, DIVERT ALL STORM WATER RUNOFF AND DRAINAGE FROM THE TEMPORARY
CONSTRUCTION INGRESS/EGRESS PAD TO A SEDIMENT TRAP OR BASIN.
MAINTENANCE
_ INSPECT DAILY.
_ RESHAPE PAD AS NEEDED FOR DRAINAGE AND RUNOFF CONTROL.
_ TOP-DRESS WITH CLEAN AGGREGATE AS NEEDED.
_ IMMEDIATELY REMOVE MUD AND SEDIMENT TRACKED OR WASHED ONTO PUBLIC ROADS.
_ FLUSHING SHOULD ONLY BE USED IF THE WATER FROM THE CONSTRUCTION DRIVE CAN BE CONVEYED
INTO A SEDIMENT TRAP OR BASIN.
REFERENCED IN CHAPTER 7 PAGE 22 AND 23 IN INDIANA STORM WATER QUALITY MANUAL.
WIDTH:
(A) - 20' MINIMUM OR FULL WIDTH
OF ENTRANCE/EXIT DRIVE,
WHICHEVER IS GREATER.
TEMPORARY CONSTRUCTION INGRESS/EGRESS PAD
SMALL SITES - LESS THAN TWO ACRES (NO SCALE)
GEOTEXTILE FABRIC UNDERLINER
#2 STONE AGGREGATE
PUBLI
C ROA
D
#2 STONE AGGRE
G
A
T
E
(OPTIONAL)
2"-3"(MIN.) (OPTIONAL)
150' (MIN.)
6" (MIN.)
07/14/21
EROSION CONTROL BLANKET
STAPLE PATTERN
1. PREPARE SOIL BEFORE INSTALLING ROLLED EROSION CONTROL PRODUCTS (RECP's), INCLUDING
ANY NECESSARY APPLICATION OF LIME, FERTILIZER, AND SEED. NOTE: WHEN USING CELL-O-SEED
DO NOT SEED PREPARED AREA. CELL-O-SEED MUST BE INSTALLED WITH PAPER SIDE DOWN.
2. BEGIN AT THE TOP OF THE SLOPE BY ANCHORING THE RECP'S IN A 6" (15 CM) DEEP X 6" (15 CM)
WIDE TRENCH WITH APPROXIMATELY 12" (30 CM) OF RECP'S EXTENDED BEYOND THE UP-SLOPE
PORTION OF THE TRENCH. ANCHOR THE RECP'S WITH A ROW OF STAPLES/STAKES
APPROXIMATELY 12" (30 CM) APART IN THE BOTTOM OF THE TRENCH. BACKFILL AND COMPACT
THE TRENCH AFTER STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMAINING 12" (30
CM) PORTION OF RECP'S BACK OVER SEED AND COMPACTED SOIL. SECURE RECP'S COVER
COMPACTED SOIL WITH A ROW OF STAPLES/STAKES SPACED APPROXIMATELY 12" (30 CM) APART
ACROSS THE WIDTH OF THE RECP'S.
3. ROLL THE RECP'S (A.) DOWN OR (B.) HORIZONTALLY ACROSS THE SLOPE. RECP'S WILL UNROLL
WITH APPROPRIATE SIDE AGAINST THE SOIL SURFACE. ALL RECP's MUST BE SECURELY FASTENED
TO SOIL SURFACE BY PLACING STAPLES/STAKES IN APPROPRIATE LOCATIONS AS SHOWN IN THE
STAPLE PATTERN GUIDE. WHEN USING THE DOT SYSTEM , STAPLES/STAKES SHOULD BE PLACED
THOUGH EACH OF THE COLORED DOTS CORRESPONDING TO THE APPROPRIATE STAPLE
PATTERN.
4. THE EDGES OF PARALLEL RECP's MUST BE STAPLED WITH APPROXIMATELY 2" - 5" (5 CM - 12.5 CM)
OVERLAP DEPENDING ON RECP's TYPE.
5. CONSECUTIVE RECP'S SPLICED DOWN THE SLOPE MUST BE PLACED END OVER END (SHINGLE
STYLE) WITH AN APPROXIMATE 3" (7.5 CM) OVERLAP. STAPLE THROUGH OVERLAPPED AREA,
APPROXIMATELY 12" (30 CM) APART ACROSS ENTIRE RECP's WIDTH. NOTE: IN LOOSE SOIL
CONDITIONS, THE USE OF STAPLE R STAKE LENGTHS GREATER THAN 6" (15 CM) MAY BE
NECESSAY TO PROPERLY SECURE THE RECP's.
2"-5" (5 CM-12.5CM)
12" (30 CM)6" (15 CM)6" (15 CM)
SLOPE INSTALLATION
OUTLET EROSION CONTROL PROTECTION
DRAIN PIPE WITH
FLAIRED END
SECTION
DEPTH OF RIP-RAP AS
INDICATED ON PLAN 12"
MINIMUM AW= FEETGEOTEXTILE FABRIC
OR WELL GRADED
AGGREGATE
AT= FEET
AL= APRON LENGTH
AT= APRON THICKNESS
AW= APRON WIDTH
STONE PLACED AROUND
END OF DRAIN PIPE TO
PREVENT SLOPE EROSION
AND UNDERCUTTING OF
THE PIPE
ENERGY DISSIPATER (OUTLET PROTECTION)
1. DIVERT SURFACE WATER RUNOFF AROUND THE STRUCTURE DURING
CONSTRUCTION SO THAT THE SITE CAN BE PROPERLY DEWATERED FOR
FOUNDATION PREPARATION.
2. EXCAVATE FOUNDATION AND APRON AREA SUBGRADES BELOW DESIGN ELEVATION
TO ALLOW FOR THICKNESS OF THE FILTER MEDIUM AND RIPRAP.
3. COMPACT ANY FILL USED IN SUBGRADE PREPARATION TO THE DENSITY OF
SURROUNDING UNDISTURBED SOIL MATERIAL.
4. SMOOTH SUBGRADE ENOUGH TO PROTECT GEOTEXTILE FABRIC FROM TEARING.
5. PLACE GEOTEXTILE FABRIC OR AGGREGATE BEDDING MATERIAL (FOR STABILIZATION
AND FILTRATION) ON THE COMPACTED AND SMOOTHED FOUNDATION.
6. INSTALL RIPRAP TO THE LINES AND ELEVATIONS SHOWN IN THE CONSTRUCTION
PLANS. BLEND RIPRAP SMOOTHLY TO SURROUNDING GRADE. IF THE CHANNEL IS
WELL DEFINED, EXTEND THE APRON ACROSS THE CHANNEL BOTTOM AND UP THE
CHANNEL BANKS TO AN ELEVATION OF SIX INCHES ABOVE THE MAXIMUM TAILWATER
DEPTH OR TO THE TOP OF THE BANK, WHICHEVER IS LESS.
7. IF GEOTEXTILE FABRIC TEARS WHEN PLACING RIPRAP, REPAIR IMMEDIATELY BY
LAYING AND STAPLING A PIECE OF FABRIC OVER DAMAGED AREA, OVERLAPPING THE
UNDAMAGED AREAS BY AT LEAST 12 INCHES.
8. CONSTRUCT A SMALL PLUNGE POOL WITHIN THE OUTLET APRON. (RIPRAP APRONS
MUST BE LEVEL WITH OR SLIGHTLY LOWER THAN THE RECEIVING CHANNEL AND
SHOULD NOT PRODUCE AN OVERFALL OR RESTRICT FLOW OF THE WATER
CONVEYANCE STRUCTURE.)
MAINTENANCE
_ INSPECT WITHIN 24 HOURS OF A RAIN EVENT AND AT LEAST ONCE EVERY SEVEN
CALENDAR DAYS.
_ INSPECT FOR STONE DISPLACEMENT; REPLACE STONES ENSURING PLACEMENT AT
FINISHED GRADE.
_ CHECK FOR EROSION OR SCOURING AROUND SIDES OF THE APRON; REPAIR
IMMEDIATELY.
_ CHECK FOR PIPING OR UNDERCUTTING; REPAIR IMMEDIATELY.
REFERENCE IN CHAPTER 7 PAGE 121 IN THE INDIANA STORM WATER QUALITY MANUAL
AT=1.5' X D50 15" OR
LESS, 1.2' X D50 15"
OR LARGER STONE.
PIPE SIZE
(D50)
C106STORMWATER POLLUTION PREVENTION PLAN DETAILSW190582-C103 swppp det(NO SCALE)
AVERAGE RIPRAP DIAMETER APRON WIDTH APRON LENGTH
8 IN.
12 IN.
18 IN.
24 IN.
30 IN.
36 IN. 14 IN.
12 IN.
10 IN.
8 IN.
5 IN.
3 IN. 2 TO 3 FEET
3 TO 4 FEET
4 TO 6 FEET
6 TO 8 FEET
8 TO 10 FEET
10 TO 12 FEET 16 TO 32 FEET
14 TO 28 FEET
12 TO 22 FEET
8 TO 18 FEET
6 TO 12 FEET
5 TO 7 FEET
SIDE
AL= FEET
DITCH BED
PLAN
AL= FEET
RIP-RAP
DIA.DIA. DIA.(NO SCALE)
EROSION CONTROL Products
Guaranteed SOLUTIONS
14649 HIGHWAY 41 NORTH
EVANSVILLE, IN 47725
800-720-2040
www.nagreen.com
(NO SCALE)
GENERAL STAPLE RECOMMENDATIONS
STAPLE PATTERNS APPLY TO ALL NORTH AMERICAN GREEN EROSION CONTROL BLANKETS.
STAPLE PATTERNS MAY VARY DEPENDING UPON SOIL TYPE AND AVERAGE ANNUAL RAINFALL.
AT SLOPE LENGTHS GREATER THAN 300 FEET OR WHERE DRAINAGE OVER LARGE AREAS
IS DIRECTED ONTO THE BLANKETS, STAPLE PATTERN "C" SHOULD BE UTILIZED.
CHANNEL LININGS REQUIRED A 2.0' MINIMUM OVERLAP AT LONGITUDINAL JOINTS.
SIDESLOPES SHALL REQUIRE A 6" MINIMUM OVERLAP. WHERE OVERLAPS OCCUR,
THE UPSTREAM BLANKET SHALL OVERLAP THE DOWNSTREAM.
IF OTHER THAN NORTH AMERICAN GREEN EROSION CONTROL BLANKETS ARE INSTALLED
FOLLOW THE INSTALLATION DIRECTIONS RECOMMENDED BY THAT PRODUCTS COMPANY.
CHANNEL LININGS UTILIZE STAPLE PATTERN
"C" WITH ADDITIONAL STAPLES ON SIDE SLOPES.
1 1/2 STAPLE PER SQ. YD.
2 STAPLE PER SQ. YD.
ADDITIONAL STAPLES
AS REQUIRED
SLOPE GRADIENT
CHANNEL
LININGSLOPE LENGTH IN FEET300
275
250
225
200
175
150
125
100
75
50
25 1 STAPLE PER SQ. YD.
TABLE 1. SIZING FOR FLOW DISSIPATERS AT CULVERT PIPE OUTLETS REVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, Indiana W19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
EXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJSENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
07/14/21
WEST C
A
R
M
E
L
D
R
I
V
E
S00°05'46"E(M) S00°45'10"W(D) 411.64'N00°05'46"W(M) N00°45'10"E(D) 398.63'S89°17'51"W(M) N89°51'24"W(D) 226.23'
N00°50'56"W(M)
N89°26'06"E(M) S89°42'58"E(D) 189.95'S00°50'56"E(M)S00°00'00"E (D)181.33'(M) 182.73'(D)N89°48'49"E(M) S89°20'15"E(D) 190.00' N89°25'05"E(M) S89°43'58"E(D) 241.02'
S89°17'51"W(M)
N89°51'24"W(D)
299.23'
DELTA=10°06'20"
R=561.07'
T=49.61'
L=98.96'
CH BRG=N83°08'42"W(M)
CH LEN=98.83'
PROPOSED BUILDING
20,121SF± PER FLOOR
F.F.E. = 829.85
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
DRY POND
UP
A. REFERTOA001-A002FORGENER ALNOTES, WALL TYPES ,SYMBOLSA NDT YPICA LCONSTRU CTIONDET AILS.B.PROVIDE BULLN OSE CMUA TALL EXPOSEDC MUC ORN ERS.C. PROVIDE MOIS TUREA NDMOLD RESIST ANTGYPSU MWA LLBOARDA TTHEAPP ARAT USBA YAND ALL ROOMSDIR ECTLY OFF OFIT.D.PROVIDE MOIS TUREA NDMOLD RESIST ANTGYPSU MWA LLBOARDA TALL WETWA LLSIN KITCH ENS, ANDA LLW ALLSA NDC EILINGSINB ATHR OOMSANDJAN ITOR CLOS ETS.E.PROVIDE HIGH -IMPA CTGY PSUMWAL LBOA RDAT ALLC ORRID ORS, STAIR CASE SAN DTHE LOBB Y.F. PLA NKEY NOTE SAPP LYTOSHEET SA10 1,A10 2AN DA110.GENERAL PLA NNOTE S
S2
S1
S3
S2
A1
H1 P1
H3
B2
H5H4
P1
H3
H3
P3
P3
P1
P3
H8
B3
B6
B5
B6
B4
H6
H6
H6
H6
H6
H7
H7
A3
P3
P3
P3
B6
B6
B2
P1
A2
A2
A2
H8
H8
H9
H9
H9
H9
H9
C200SITE PLANW190582-C200 siteSITE PLAN GENERAL NOTES
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING, OR
VERIFYING THAT ALL PERMITS AND APPROVALS ARE OBTAINED FROM
THE RESPECTIVE CITY, COUNTY, AND STATE AGENCIES PRIOR TO
STARTING CONSTRUCTION.
2. ALL QUANTITIES GIVEN ON THESE PRINTS, VERBALLY OR IN THE
SCOPE OF WORK SECTION ARE ESTIMATES AND SHALL BE CONFIRMED
BY THE BIDDING CONTRACTORS.
3. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA)
STANDARDS FOR EXCAVATIONS; FINAL RULE 29 CFR PART 1926,
SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET
IN DEPTH. IN ADDITION, EXCAVATION EXCEEDING TWENTY (20) FEET IN
DEPTH REQUIRE THE DESIGN OF A TRENCH SAFETY SYSTEM BY A
REGISTERED PROFESSIONAL ENGINEER.
4. IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER AND
CONTRACTOR TO MAINTAIN QUALITY CONTROL THROUGHOUT THIS
PROJECT.
5. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO
CONFORM TO APPLICABLE LOCAL STANDARDS.
6. BEARINGS, DIMENSIONS, AND EASEMENTS ARE SHOWN FOR
REFERENCE ONLY. SEE RECORD SURVEYS AND PLATS FOR EXACT
INFORMATION.
7. THE ENGINEER AND/OR OWNER DISCLAIM ANY ROLE IN THE
CONSTRUCTION MEANS AND METHODS ASSOCIATED WITH THE
PROJECT.
8. ALL DIMENSIONS ARE BASED ON FACE OF CURB OR BACK OF ROLL
CURB OR FACE OF BUILDING.
9. SEE ARCHITECTURAL PLANS FOR DETAILS OF BUILDING, BUILDING
DIMENSIONS AND SIGNAGE SPECIFICATIONS. DO NOT STAKE BUILDING
FROM THESE PLANS.
10. COORDINATE CONSTRUCTION ACTIVITIES WITH ADJOINING WORK IF
APPLICABLE. VERIFY EXTENT OF ADJOINING WORK AND COORDINATE
AS REQUIRED.
11. FIELD VERIFY EXISTING CURBS AND TAPER PROPOSED VERTICAL
CURBS TO MATCH WITHIN A MIN. OF THREE (3) FEET.
12. ± DIMENSIONS INDICATE FIELD DIMENSION ADJUSTMENT AREA BASED
ON ACTUAL FIELD LAYOUT COORDINATES.
13. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD PRIOR
TO START OF CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR ALL FIELD DIMENSIONS. IF ANY DISCREPANCIES
ARE FOUND IN THESE PLANS FROM ACTUAL FIELD CONDITIONS, THE
CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY.
14. PROVIDE SMOOTH TRANSITION FROM NEWLY PAVED AREAS TO
EXISTING AREAS AS NECESSARY. ALL AREAS WHERE PROPOSED
PAVEMENT MEETS EXISTING PAVEMENT, THE EXISTING EDGE OF
PAVEMENT SHALL BE FREE OF ALL LOOSE DEBRIS. THE EDGE OF
EXISTING ASPHALT PAVEMENT SHALL BE PROPERLY SEALED WITH A
TACK COAT MATERIAL IN ALL AREAS WHERE NEW ASPHALT PAVEMENT
IS INDICATED TO JOIN EXISTING.
15. RESURFACE OR RECONSTRUCT AT LEAST TO ORIGINAL CONDITIONS
ALL AREAS WHERE THE EXISTING PAVEMENT OR LAWNS ARE
DAMAGED DURING CONSTRUCTION FROM TRAFFIC BY CONTRACTORS,
SUBCONTRACTORS, OR SUPPLIERS AFTER CONSTRUCTION WORK IS
COMPLETE.
16. THE CONTRACTOR SHALL PROTECT AND NOT DESTROY THE
PROPERTY CORNER MONUMENTS DURING CONSTRUCTION.
17. REFER TO ARCHITECTURAL PLANS FOR BUILDING ACCESSORY
DETAILS.
18. REFER TO SHEET C201 FOR SITE PLAN DETAILS UNLESS OTHERWISE
NOTED.
SITE DATA
SITE AREA = 4.37± AC
BUILDING AREA = 20,121± SF PER FLOOR
PERCENT IMPERVIOUS = 87%
ZONING = I-1
FRONT YARD BSL REQUIRED = 0' FT MIN.
10' MAX.
REAR YARD BSL REQUIRED = 0' FT
SIDE YARD BSL REQUIRED = 0' FT
PARKING REQUIRED:
PARKING REQUIREMENT: 1 PER
EMPLOYEE
PARKING DIMENSIONS = 9' x 18'
BIKE PARKING REQUIRED = 4 SPACES
PARKING PROVIDED:
10 - STANDARD SPACES
1 - ADA SPACES
11 - TOTAL SPACES
SITE PLAN NOTES
PAVEMENT
STANDARD DUTY ASPHALT PAVING
STANDARD DUTY CONCRETE
MATCH EXISTING PAVEMENT
HARDSCAPE
INTEGRAL WALK AND CURB
CONCRETE PARKING BARRIER
CONCRETE SIDEWALK
ACCESSIBLE RAMP
PAVEMENT FLUSH WITH SIDEWALK
CONCRETE CURB WITH VARIABLE HEIGHT .
REFER TO C300 FOR GRADES.
TAPER CURB WITHIN 3' AT THE END OF THE CURB RUN
RETAINING WALL WITH VARIABLE HEIGHT.
REFER TO C300 FOR GRADES.
SLOTTED DRAIN IN CONCRETE APRON. SEE DETAIL ON SHEET C602
BUILDING ACCESSORIES
NOT USED
CANOPY
CONCRETE CURB OF VARYING HEIGHT LOCATED ALONG THE
FACADE FOR VEHICLE PROTECTION. REFER TO C300 FOR GRADES.
ENTRY GATE TO MAINTAIN A 20' CLEAR ZONE MIN.
ACCESS PANEL
BOLLARDS
ACCESSORIES
CONNECT EXISTING FENCE TO BUILDING
PROVIDE NEW FENCE FROM THE SECURITY GATE SOUTH ALONG
THE DRIVE AND CONNECT TO THE OLD FENCE. COORDINATE
LIMITS WITH OWNER REP.
FIRE HYDRANT WITH BOLLARD PROTECTION
SIGNAGE & MARKINGS
ACCESSIBLE PARKING SPACE & SIGN ON BUILDING
4" PAINTED WHITE SOLID LINES (TYP)
4" PAINTED WHITE SOLID LINE ISLAND
H1
H2
H3
H4
H5
B1
B2
A1
S1
S2
S3
P1
P2
P3
ELECTRICAL RISER
GUY ANCHOR
ELECTRIC JUNCTION BOX
ORNAMENTAL LIGHT
GENERATOR
STREET LIGHT
ELECTRIC MANHOLE
ELECTRIC OUTLET
UTILITY POLE
UTILITY POLE W/ TRANSFORMER
TRANSFORMER
COMMUNICATIONS JUNCTION BOX
COMMUNICATIONS MANHOLE
COMMUNICATIONS PEDESTAL
RIGHT OF WAY LINE
FENCE
GUARD RAIL
BUILDING SETBACK LINE
BOUNDARY LINE
CISTERN
DRINKING FOUNTAIN
FIRE DEPT HOOKUP
FIRE HYDRANT
POST INDICATOR VALVE
CHILLED WATER MANHOLE
WATER MANHOLE
SPRINKLER CONTROL BOX
SPRINKLER CONTROL VALVE
SPRINKLER
SPIGOT
WELL HEAD
WATER METER
WATER VALVE
GAS METER
GAS VALVE
ELECTRIC METER
LIQUID PROPANE GAS TANK
MONITORING WELL
TRAFFIC SIGNAL POLE
TRAFFIC SIGNAL
BOLLARD
FLAG POLE
PARKING METER
POST
SIGN
PARKING WHEEL STOP
DOWN SPOUT
ACCESSIBLE SPACE
GATE POST
COMMUNICATIONS RISER
STORM CLEANOUT
BEEHIVE INLET
CURB INLET
FLOOR DRAIN
ROUND INLET
SQUARE INLET
STORM MANHOLE
SANITARY SEWER CLEANOUT
LIFT STATION
SANITARY SEWER MANHOLE
SANITARY STUB MARKER
SEPTIC TANK
PARKING LOT LIGHT (1 HEAD)
PARKING LOT LIGHT (3 HEAD)
PARKING LOT LIGHT (4 HEAD)
PARKING LOT LIGHT (2 HEAD) STANDARD DUTY ASPHALT
CONCRETE PAVEMENT
DISTRIBUTION BOX
ROW RIGHT OF WAY
BSL BUILDING SETBACK LINE
ESMT EASEMENT
D.&U.E. DRAINAGE AND UTILITY EASEMENT
FFE FINISH FLOOR ELEVATION
12 PARKING COUNT
EXISTING ASPHALT
PAVEMENT
SITE PLAN LEGEND
UTILITIES
ABBREVIATIONS
OTHER
LINE TYPES
SECTION LINE REVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, IndianaW19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY 10.13.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
EXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJS
W
S
N
E E N G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil Engi neeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
10/13/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJSFINAL CONSTRUCTION PLANS 09.14.2020 BJSBID ADDENDUM 001 10.13.2020 BJS
B3
B4
B5
B6
H6
H7
A2
A3
H8
H9
07/14/21
NOTE:
12"X18" 18 GAUGE HOT DIP GALVANIZED NON-REFLECTIVE SIGN WITH 12'
POST DRIVEN 4 FEET INTO GROUND. POST SHALL BE 12' LONG
GALVANIZED 2 1/2" OD STEEL POSTS. SET BOTTOM OF SIGN 7' ABOVE
GRADE.
USE 6" PIPE BOLLARD FILLED W/
CONCRETE ONLY WHEN SIGN IS
IN PAVED AREA OR SIDEWALK
1'-6"3'-9"7'-0" (MIN)VARIESACCESSIBLE SIGN BOLLARD
MOUNT DETAIL
ALL SIGNS SHALL COMPLY WITH U.S. DEPARTMENT OF TRANSPORTATION,
FEDERAL HIGHWAY ADMINISTRATION'S "MANUAL OF UNIFORM TRAFFIC
CONTROL DEVICES", LOCAL CODES AND AS SPECIFIED. MOUNT SIGNS TO
POST IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
WHERE PARKING SPACES THAT ARE RESERVED FOR PERSONS WITH
DISABILITIES ARE DESIGNATED TO ACCOMMODATE WHEELCHAIR VANS, A VAN
ACCESSIBLE (R7-8P) PLAQUE SHALL BE MOUNTED BELOW THE R7-8 SIGN.
THE R7-8SIGN SHALL HAVE A GREEN LEGEND AND BORDER AND A WHITE
WHEELCHAIR SYMBOL ON A BLUE SQUARE ALL ON A WHITE BACKGROUND.
THE R7-8P PLAQUE SHALL HAVE A GREEN LEGEND AND BORDER ON A WHITE
BACKGROUND.3'-6"3 LBS./FT. GALVANIZED CHANNEL
SIGN POST PER INDOT STANDARD
SPECIFICATION SEC. 910.14.
ACCESSIBLE SIGNS
ACCESSIBLE PARKING
SYMBOL DETAIL
STANDARD DUTY CONCRETE PAVING SECTION
STANDARD DUTY ASPHALT PAVING SECTION
INTEGRAL WALK AND CURB DETAIL
C201SITE PLAN DETAILSW190582-C201 site det(NO SCALE)
4"-#53 AGGREGATE (INDOT)
6" CONC. (4000 PSI)
W/FIBER ADDITIVE
(NO SCALE)
6"-#53 AGGREGATE (INDOT)
2.5"-HMA 19.0MM BASE
1.5"- HMA 9.5MM SURFACE
(NO SCALE)
THIS SIGN
TYPICAL AT ALL
ACCESSIBLE
PARKING SPACES
THIS SIGN TYPICAL AT
ALL VAN ACCESSIBLE
PARKING SPACES
PENALTY SIGN WITH
WORDING AS REQUIRED
BY STATE OR LOCAL LAW
SLOPE TOP
OF CONCRETE
GROUND/PAVING SURFACE
3500 P.S.I.
P.C. CONCRETE
3"12" X 6"
12" X 9"
10" DIA.18"1"
18"R
7"
11"
4" (TYP.)
NOTE:
ALL STRIPES TO BE PAINTED WHITE.
MINIMUM = 3"
SPECIAL = 4"
(NO SCALE)
RESERVED
PARKING
1" RAD.
ALL CORNERS
12" 18"4"8"
2.0% MAX. SLOPE
CLASS "A" CONCRETE
18"SCORE
PAVEMENT6"6"
1/8"RAD.
2"2"18"EXISTING
GROUND
EARTH
BACKFILL
4"
TOPSOIL
6"6"PAVEMENT R1.
5"
(NO SCALE)
TYPICAL
SIDEWALK SECTION
5.0' (MIN.)
4" CLASS "A"
CONCRETE
1/2" PREFORMED JOINT FILLER
TRANSVERSE JOINT
TRANSVERSE JOINT
1/2" PREFORMED JOINT FILLER
(NO SCALE)
CURB DETAIL
(NO SCALE)
(NO SCALE)
PARKING BARRIER
(NO SCALE)
VARIES (SEE PLANS)
1" RAD.
R7-8 R7-8P
5°
20°
PRECAST CONC. PARKING
BARRIER WITH 2-#3 REBARS
USE 4000 PSI CONC.
BEVELED
E
D
G
E
#5 REBAR 1'-6"
WITH 3/4" HOLE CAST
FACE OF CU
R
B
O
R
EDGE OF AS
P
H
A
L
T 30"
6.0'
7 5/8"
0.5'HEIGHT OF SYMBOL:MINIMUM = 28"SPECIAL = 41"WIDTH OF SYMBOL:
MINIMUM = 24"
SPECIAL = 36"NOTE:
BLUE BACKGROUND AND
WHITE BORDER ARE OPTIONAL
VAN
ACCESSIBLE
12"
NOTE:
WHERE PARKING SPACES THAT ARE RESERVED FOR PERSONS WITH
DISABILITIES ARE DESIGNATED TO ACCOMMODATE WHEELCHAIR VANS, A
VAN ACCESSIBLE (R7-8P) PLAQUE SHALL BE MOUNTED BELOW THE R7-8
SIGN. THE R7-8SIGN SHALL HAVE A GREEN LEGEND AND BORDER AND A
WHITE WHEELCHAIR SYMBOL ON A BLUE SQUARE ALL ON A WHITE
BACKGROUND. THE R7-8P PLAQUE SHALL HAVE A GREEN LEGEND AND
BORDER ON A WHITE BACKGROUND.6"RESERVED
PARKING
VAN
ACCESSIBLE
3"3"(R7-8P)
(R7-8)
8' MIN. VAN
(5' MIN. CAR)9' 9'
ACCESSIBLE PARKING SPACES
NOTE:
ALL PAINT TO BE BLUE NON-SKID SURFACE
APPLICATION OF CILICA SAND OR GLASS BEAD BY
METHOD OF MIXTURE AND OR BROADCASTING.
PROPOSED ADA SIGNS
ON 3" DIAMETER POST
(SEE SIGN DETAILS)18'(NO SCALE)
PREPARED SUBGRADE
COMPACTED PER INDOT
STANDARD SPECIFICATIONS
PREPARED SUBGRADE
COMPACTED PER INDOT
STANDARD SPECIFICATIONS
PREPARED SUBGRADE COMPACTED PER INDOT
STANDARD SPECIFICATIONS. MAY REQUIRE
TREATMENT BEFORE PAVING.
PREPARED SUBGRADE COMPACTED PER INDOT
STANDARD SPECIFICATIONS. MAY REQUIRE
TREATMENT BEFORE PAVING.
MIN. 4" COMPACTED
#53 STONE BASE
MIN. 4" COMPACTED
#53 STONE BASE
6'-0" (MAX.) BETWEENTRANSVERSE JOINTS48.0' (MAX.) BETWEEN EXPANSION JOINTSREVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, IndianaW19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
EXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJSE N G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil Engi neeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
07/14/21
E
OHU OHU OHUOHU OHU OHU OHU OHU
OHU
OH U
OHU
OHU
OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU
G
W
W W
G
G
W
WEST C
A
R
M
E
L
D
R
I
V
E
GGG
PROPOSED BUILDING
20,121SF± PER FLOOR
F.F.E. = 829.85
D D D D D DDD DD D D D D D DD
D
D
D
D D D D D D D D D D D D D D D DD D D DD D D D D D D D D D D D D D D DCSTM STM STM STM STM STMSTM STM STM STM STM STM STMESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS W W W W W W W W W W W W W WW W W WEE E E E E EE E E E EEDRY POND
RIP RAP REVETMENT PAD
UP
A. REFERTOA001-A002FORGENER ALNOTES, WALL TYPES ,SYMBOLSA NDT YPICA LCONSTRU CTIONDET AILS.B.PROVIDE BULLN OSE CMUA TALL EXPOSEDC MUC ORN ERS.C. PROVIDE MOIS TUREA NDMOLD RESIST ANTGYPSU MWA LLBOARDA TTHEAPP ARAT USBA YAND ALL ROOMSDIR ECTLY OFF OFIT.D.PROVIDE MOIS TUREA NDMOLD RESIST ANTGYPSU MWA LLBOARDA TALL WETWA LLSIN KITCH ENS, ANDA LLW ALLSA NDC EILINGSINB ATHR OOMSANDJAN ITOR CLOS ETS.E.PROVIDE HIGH -IMPA CTGY PSUMWAL LBOA RDAT ALLC ORRID ORS, STAIR CASE SAN DTHE LOBB Y.F. PLA NKEY NOTE SAPP LYTOSHEET SA10 1,A10 2AN DA110.G ENERAL PLA NNOTE S
GENERAL GRADING NOTES
1. CONTRACTOR SHALL REFER TO THE STORMWATER POLLUTION PREVENTION PLAN AND
DETAILS FOR CONSTRUCTION SCHEDULING AND EROSION CONTROL MEASURES TO BE
INSTALLED PRIOR TO EARTHMOVING ACTIVITIES.
2. REFER TO THE INDIANA DEPARTMENT OF TRANSPORTATION (INDOT) STANDARD
SPECIFICATIONS, LATEST EDITION, FOR BASIC MATERIALS AND CONSTRUCTION METHODS.
THE SECTIONS BELOW FOR VARIOUS ITEMS ARE TO CLARIFY THE INTENT OF THE
REQUIREMENTS FOR THIS PROJECT. PLEASE NOTE THAT OTHER SECTIONS OF THE INDOT
STANDARD SPECIFICATIONS MAY ALSO BE APPLICABLE.
3. TOPSOIL SHALL BE STRIPPED FROM ALL AREAS TO RECEIVE PAVING AND FROM WITHIN THE
LIMITS OF PROPOSED BUILDINGS AND STRUCTURES. TOPSOIL SHALL BE STRIPPED TO THE
DEPTH AS NOTED IN THE GEOTECHNICAL REPORT.
4. AFTER STRIPPING TOPSOIL, PROOFROLL AREAS TO BE FILLED WITH A MEDIUM WEIGHT
ROLLER TO DETERMINE LOCATIONS OF ANY POCKETS OF UNSUITABLE MATERIAL.
RECOMMENDATIONS FOR DRYING, AMENDING AND/OR REMOVAL OF ANY UNSUITABLE
MATERIAL WITHIN THE PROPOSED PAVED AND/OR BUILDING AREAS WILL BE DETERMINED AT
THE TIME OF CONSTRUCTION BY THE OWNER'S GEOTECHNICAL TESTING REPRESENTATIVE.
5. TOPSOIL SHALL BE PLACED IN MOUNDING AREAS, NONSTRUCTURAL FILL AND/OR PLANTING
AREAS TO A MINIMUM DEPTH OF 6". EXCESS TOPSOIL SHALL BE REMOVED FROM THE SITE.
6. WHEN PERFORMING GRADING OPERATIONS DURING PERIODS OF WET WEATHER, PROVIDE
ADEQUATE DEWATERING, DRAINAGE AND GROUND WATER MANAGEMENT TO CONTROL
MOISTURE OF SOILS. REFER TO GEOTECHNICAL REPORT AND/OR CONSULT WITH OWNER'S
GEOTECHNICAL TESTING REPRESENTATIVE FOR RECOMMENDATIONS.
7. FILL MATERIAL SHALL CONSIST OF EARTH OBTAINED FROM CUT AREAS, BORROW PITS OR
OTHER APPROVED SOURCES. EARTH SHALL BE FREE FROM ORGANIC MATTER AND OTHER
DELETERIOUS SUBSTANCES AND LARGE ROCKS. THE FILL MATERIAL SHALL BE PLACED IN
LAYERS NOT TO EXCEED SIX INCHES FOLLOWING COMPACTION, PROPER MOISTURE
CONTENT OF FILL MATERIAL WILL BE SUCH TO ACHIEVE SPECIFIED COMPACTION DENSITY.
ALL FILL BENEATH PAVED AREAS, FLOOR SLABS AND FUTURE BUILDINGS SHALL BE
COMPACTED TO AT LEAST 95% OF THE MAXIMUM DRY DENSITY PER ASTM D-1557. FIELD
COMPACTING TEST SHALL BE RUN ON EACH LIFT, IN FILL SECTIONS, AND THE REQUIRED
COMPACTION ON EACH LIFT SHALL BE IN ACCORDANCE WITH INDOT SECTION 211.
8. MAXIMUM LAWN SLOPE IS 3:1.
9. THE PLANS SHOW THE LOCATION OF ALL KNOWN UTILITIES LOCATED WITHIN THE LIMITS OF
CONSTRUCTION ACCORDING TO INFORMATION PROVIDED BY THE VARIOUS UTILITY
COMPANIES, PREVIOUS CONSTRUCTION PLANS AND AS EVIDENCED BY OBSERVATION OF
ABOVE GROUND CONDITIONS BY THE SURVEYOR. THE ACCURACY OF THIS INFORMATION IS
NOT GUARANTEED.
10. THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES TO LOCATE MAINS, CONDUITS,
SERVICE LINES, ETC. WITHIN THE CONSTRUCTION LIMITS. THE LOCATION AND PROTECTION
OF UTILITY STRUCTURES, THEIR SUPPORT AND MAINTENANCE DURING CONSTRUCTION (IN
COOPERATION WITH APPLICABLE UTILITY COMPANY) IS THE EXPRESSED RESPONSIBILITY OF
THE CONTRACTOR.
11. ALL SPOT ELEVATIONS ARE TO FINISHED GRADE.
12. COMPACTED "B" BORROW BACK FILL REQ'D. OVER ALL UTILITIES IN PAVED AREAS.
13. ALL GRADES AT BOUNDARY SHALL MEET EXISTING. CONTRACTOR SHALL ADJUST AND/OR
CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND CONTINUOUS
GRADE. BUTT JOINTS SHALL BE PROVIDED AT TRANSITIONAL AREAS BETWEEN PROPOSED
AND EXISTING PAVEMENT.
14. ANY PART OF SANITARY OR STORM SEWER TRENCHES RUNNING UNDER OR WITHIN 5' OF
PAVEMENT TO BE BACKFILLED WITH GRANULAR MATERIAL.
15. ALL CONSTRUCTION ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH O.S.H.A.
STANDARDS FOR WORKER SAFETY.
16. THE CONTRACTOR SHALL CONFIRM ALL EARTHWORK QUANTITIES PRIOR TO THE START OF
CONSTRUCTION. IF AN EXCESS OR SHORTAGE OF EARTH IS ENCOUNTERED, THE
CONTRACTOR SHALL CONFIRM WITH THE OWNER AND ENGINEER THE REQUIREMENTS FOR
STOCKPILING, REMOVAL OR IMPORTING OF EARTH.
17. PROVIDE POSITIVE DRAINAGE WITHOUT PONDING IN ALL AREAS AFTER INSTALLATION.
CONTRACTOR TO TEST FOR AND CORRECT ANY PONDING CONDITIONS. ANY AREAS THAT
HOLD WATER MORE THAN 1/8" DEEP SHALL BE CUT OUT AND CORRECTED TO POSITIVE
DRAINAGE AT NO COST TO THE OWNER/ DEVELOPER OR ENGINEER.
18. ADA ACCESSIBLE PARKING SPACES, RAMPS, AND ROUTES SHALL BE IN ACCORDANCE WITH
THE LATEST ADA STANDARDS FOR ACCESSIBLE DESIGN.
19. VERTICAL CURVES, WITH A MINIMUM LENGTH OF 50', SHALL BE USED WHERE POSSIBLE
BETWEEN VERTICAL CHANGES IN DIRECTION (SLOPE) TO ALLOW FOR POSITIVE DRAINAGE
AND SMOOTH TRANSITIONS.
20. CONTRACTOR TO INSTALL CONCRETE CRADLES WHEN THE VERTICAL SEPARATION (AS
MEASURED FROM THE EXTERIOR OF THE PIPES) BETWEEN SANITARY SEWER FACILITIES,
WATER MAIN, AND STORM SEWERS IS 18" OR LESS.
21. ALL DISTURBED AREA SHALL BE STABILIZED IN ACCORDANCE TO THE STORM WATER
POLLUTION PREVENTION PLAN AND LANDSCAPE PLAN.
GENERAL NOTES
THE SITE DOES NOT LIE IN A SPECIAL FLOOD HAZARD
AREA AS ESTABLISHED BY THE FEDERAL
EMERGENCY MANAGEMENT AGENCY - NATIONAL
FLOOD INSURANCE PROGRAM, WHEN PLOTTED BY
SCALE ON FLOOD INSURANCE RATE MAP
#18057C0209 G, DATED NOVEMBER 19, 2014.
BENCHMARK DATA
EXISTING AREAS
PERVIOUS = 0.65 AC.
IMPERVIOUS = 3.72 AC.
PROPOSED AREAS
PERVIOUS = 0.53 AC.
IMPERVIOUS = 3.84 AC.
POND DETENTION SUMMARY
PEAK DISCHARGE (CFS)
RETURN PERIOD
10 YR.
100 YR.
0.03 0.03
ALLOWABLE ACTUAL
0.09 0.07
NET SITE ACREAGE (MINUS ROW)
DETENTION VOLUME REQUIRED
DETENTION VOLUME PROVIDED
3.84 ACRES
4229 CF
4487 CF
C300W190582-C300 gradELECTRICAL RISER
GUY ANCHOR
ELECTRIC JUNCTION BOX
ORNAMENTAL LIGHT
GENERATOR
STREET LIGHT
ELECTRIC MANHOLE
ELECTRIC OUTLET
UTILITY POLE
UTILITY POLE W/ TRANSFORMER
TRANSFORMER
COMMUNICATIONS JUNCTION BOX
COMMUNICATIONS MANHOLE
COMMUNICATIONS PEDESTAL
RIGHT OF WAY LINE
FENCE
GUARD RAIL
BOUNDARY LINE
CISTERN
DRINKING FOUNTAIN
FIRE DEPT HOOKUP
FIRE HYDRANT
POST INDICATOR VALVE
CHILLED WATER MANHOLE
WATER MANHOLE
SPRINKLER CONTROL BOX
SPRINKLER CONTROL VALVE
SPRINKLER
SPIGOT
WELL HEAD
WATER METER
WATER VALVE
GAS METER
GAS VALVE
ELECTRIC METER
LIQUID PROPANE GAS TANK
MONITORING WELL
TRAFFIC SIGNAL POLE
TRAFFIC SIGNAL
BOLLARD
FLAG POLE
PARKING METER
POST
SIGN
PARKING WHEEL STOP
DOWN SPOUT
ACCESSIBLE SPACE
GATE POST
COMMUNICATIONS RISER
STORM CLEANOUT
BEEHIVE INLET
CURB INLET
FLOOR DRAIN
ROUND INLET
SQUARE INLET
STORM MANHOLE
SANITARY SEWER CLEANOUT
LIFT STATION
SANITARY SEWER MANHOLE
SANITARY STUB MARKER
SEPTIC TANK
PARKING LOT LIGHT (1 HEAD)
PARKING LOT LIGHT (3 HEAD)
PARKING LOT LIGHT (4 HEAD)
PARKING LOT LIGHT (2 HEAD)
DISTRIBUTION BOX
ROW RIGHT OF WAY
ESMT EASEMENT
D.&U.E. DRAINAGE AND UTILITY EASEMENT
FFE FINISH FLOOR ELEVATION
TC TOP OF CURB
GUT GUTTER
CMP CORRUGATED METAL PIPE
RCP REINFORCED CONCRETE PIPE
PVC POLYVINYL CHLORIDE PIPE
VCP VITRIFIED CLAY PIPE
HDPE HIGH DENSITY POLYETHYLENE PIPE
DIP DUCTILE IRON PIPE
SSD SUB SURFACE DRAIN PIPE
STM STORM
SAN SANITARY
STR STRUCTURE
CO CLEANOUT
GRADING PLAN LEGEND
UTILITIES
ABBREVIATIONS
OTHER
LINE TYPES
EXISTING SPOT ELEVATION
CURB & GUTTER ELEVATION
PAVEMENT SPOT ELEVATION
GROUND SPOT ELEVATION
FLOW LINE
INDEX CONTOUR
INTERMEDIATE CONTOUR
SANITARY SEWER MAIN
STORM SEWER MAIN
UNDERGROUND GAS
UNDERGROUND WATER
AERIAL ELECTRIC
UNDERGROUND ELECTRIC
UNDERGROUND COMMUNICATIONS
AERIAL COMMUNICATIONS
OVERHEAD UTILITY
FORCE MAIN
G G G
W W
E(A) E(A)
E E E
C C C
C(A) C(A)
OHU OHU
FM FM
AERIAL FIBER OPTIC CABLEFO(A) FO(A)
UNDERGROUND FIBER OPTICFO FO
EMERGENCY FLOOD ROUTE
SANITARY SEWER LATERALSAN SAN
ROOF DRAINSTM STM
SUB SURFACE DRAIN
CARMEL REQUIREMENTS
1. NO EARTH DISTURBING ACTIVITY MAY TAKE PLACE
WITHOUT AN APPROVED STORM WATER
MANAGEMENT PERMIT.
2. DECORATIVE SIGNS, SPRINKLER SYSTEMS, TREES,
LANDSCAPING MOUNDS, FENCES, LIGHT POLES OR
OTHER SUCH AMENITIES ARE NOT PERMITTED WITHIN
THE RIGHT-0F-WAY.
3. M.F.P.G. = MINIMUM FLOOD PROTECTION GRADE
M.F.P.G. OF ALL STRUCTURES FRONTING A POND OR
OPEN DITCH SHALL BE NO LESS THAN 2 FEET ABOVE
ANY ADJACENT 100-YEAR LOCAL OR REGIONAL
FLOOD ELEVATIONS, WHICHEVER IS GREATER, FOR
ALL WINDOWS, DOORS, PIPE ENTRANCES, WINDOW
WELLS, AND ANY OTHER STRUCTURE MEMBER
WHERE FLOOD WATERS CAN ENTER A BUILDING.
4. M.L.A.G. = LOWEST ADJACENT GRADE IS THE
ELEVATION OF THE LOWEST GRADE ADJACENT TO A
STRUCTURE WHEN THE SOIL MEETS THE
FOUNDATION AROUND THE OUTSIDE OF THE
STRUCTURE. (INCLUDING STRUCTURAL MEMBERS
SUCH AS BASEMENT WALKOUT, PATIOS, DECKS,
PORCHES, SUPPORT POST, OR PIERS, AND RIM OF
THE WINDOW WELL.
FLOW DIRECTION AND SLOPE
GRADING PLANREVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, Indiana W19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY10.13.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
EXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJS
W
S
N
E E N GI N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil Engi neeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
10/13/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJSFINAL CONSTRUCTION PLANS 09.14.2020 BJSBID ADDENDUM 001 10.13.2020 BJS
BM G 54 -
ISHC BRONZE DISK ON A CONCRETE POST PROJECTING 1.5
FT. OUT OF THE GROUND ALONG U.S. 31, 1.4 MILES NORTH
OF I-465, 0.4 MILES SOUTH OF 116TH STREET, 100 FT. WEST
OF CENTERLINE OF SOUTH BOUND LANE OF U.S. 31, AND 2
FT. EAST OF R/W FENCE.
BM G 55 -
ISHC BRONZE DISK ON A CONCRETE POST PROJECTING 1.5
FT. OUT OF THE GROUND ALONG U.S. 31, 2.6 MILES NORTH
OF I-465, 0.7 MILES SOUTH OF 131ST STREET, 83 FT. WEST
OF CENTERLINE OF SOUTH BOUND LANE OF U.S. 31.
BM Y 42 -
CGS DISK IN CONCRETE SLAB ON THE EAST SIDE OF THE
MONON TRAIL 218 FT. SOUTH OF 111TH STREET.
M.F.P.G. = 828.90
M.L.A.G. = 828.85
CONSTRUCTION LIMITSD D
THE FOLLOWING IS A SUMMARY OF RELEASE
RATES FOR THE PORTION OF THE DEVELOPMENT
THAT IS REQUIRED TO CREATE DETENTION, WHICH
IS THE INCREASED HARD SURFACE DUE TO THE
PROPOSED BUILDING BEING LARGER THAN THE
EXISTING BUILDING. THE ALLOWABLE RELEASE
RATES ARE BASED ON THIS ACREAGE, WHICH IS
0.30 ACRES OF NEW HARD SURFACE.
PEAK DISCHARGE (CFS)RETURN PERIOD
10 YR.
100 YR.
10.45
15.79
THE FOLLOWING IS A SUMMARY OF RELEASE
RATES FOR THE REST OF THE SITE, WHICH ARE
EXISTING AND PROPOSED WHICH FLOW SOUTH
AND WEST TO THE EXISTING STORM SEWER AT
THAT POINT. THE RUNOFF WHICH ENTER THE
PROPOSED DRY BASIN HAVE BEEN GIVEN A
SEPARATE OUTLET ORIFICE AND THOSE FLOWS
ARE INCLUDED IN THE NUMBER BELOW.
07/14/21
E
OHU OHU OHUOHU OHU OHU OHU
OHU
OH U
OHU
OHU
OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU
G
W
W W
G
G
W
WEST C
A
R
M
E
L
D
R
I
V
E
GGG
PROPOSED BUILDING
20,121SF± PER FLOOR
F.F.E. = 829.85CSTM STM STM STM STM STM STMSTM STM STM STM STM STMESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS W W W W W W W W W W W W W WW W W WEE E E E E E E E EDRY POND
330' OF DURASLOT
SLOTTED DRAIN RATED
FOR LIGHT PASSENGER
VEHICLE TRAFFIC
381' OF 10" HDPE
ROOF DRAIN @ 0.5%
CLEANOUT
TOC=829.50
INV=828.00
CLEANOUT
TOC=828.80
INV=826.42
CLEANOUT
TOC=828.50
YARD INLET
TOC=827.45
(6")INV=826.60
RIP RAP REVETMENT PAD
4
1
1
1
1
7
8
9
2
3
10 11
12
13
6
5
DRAINAGE PLAN NOTES
DOWNSPOUTS TO CONNECT TO PROPOSED ROOF DRAIN. COORDINATE
WITH ARCHITECTURAL PLANS.
330' OF 10" DURASLOT SLOTTED DRAIN RATED FOR LIGHT PASSENGER
VEHICLE TRAFFIC. REFER TO DETAILS ON SHEET C602.
CONNECT TRENCH DRAIN TO PROPOSED STRUCTURE
WATER QUALITY UNIT
CONTROL STRUCTURE
DIVERSION STRUCTURE
12' WIDE EMERGENCY OVERFLOW.
INSTALL NEW BEEHIVE STRUCTURE. CONNECT TO EXISTING 15" PIPE
AND EXTEND NEW 15" PIPE WEST TO NEW STRUCTURE WEST OF THE
PROPOSED SIDEWALK.
RECONNECT 6" OUTLET FROM THE DRAIN TO STRUCTURE 304.
NATIVE PLANTINGS WITHIN BASIN. REFER TO SPECS ON SHEET C601.
SIGN FOR NATIVE PLANTINGS. DETAIL ON SHEET C601.
CONNECT STRUCTURE 900 TO EXISTING 15" PIPE
STONE LEVEL SPREADER WITH UNDER DRAIN. REFER TO DETAIL ON
SHEET C601
C600DRAINAGE PLANW190582-C600 drainage plan1
2
3
4
5
6
ELECTRICAL RISER
GUY ANCHOR
ELECTRIC JUNCTION BOX
ORNAMENTAL LIGHT
GENERATOR
STREET LIGHT
ELECTRIC MANHOLE
ELECTRIC OUTLET
UTILITY POLE
UTILITY POLE W/ TRANSFORMER
TRANSFORMER
COMMUNICATIONS JUNCTION BOX
COMMUNICATIONS MANHOLE
COMMUNICATIONS PEDESTAL
RIGHT OF WAY LINE
FENCE
GUARD RAIL
BOUNDARY LINE
FIRE DEPT HOOKUP
FIRE HYDRANT
POST INDICATOR VALVE
CHILLED WATER MANHOLE
WATER MANHOLE
SPRINKLER CONTROL BOX
SPRINKLER CONTROL VALVE
SPRINKLER
SPIGOT
WELL HEAD
WATER METER
WATER VALVE
GAS METER
GAS VALVE
ELECTRIC METER
LIQUID PROPANE GAS TANK
MONITORING WELL
TRAFFIC SIGNAL POLE
TRAFFIC SIGNAL
BOLLARD
POST
SIGN
PARKING WHEEL STOP
DOWN SPOUT
ACCESSIBLE SPACE
GATE POST
COMMUNICATIONS RISER
STORM CLEANOUT
BEEHIVE INLET
CURB INLET
FLOOR DRAIN
ROUND INLET
SQUARE INLET
STORM MANHOLE
SANITARY SEWER CLEANOUT
LIFT STATION
SANITARY SEWER MANHOLE
SANITARY STUB MARKER
SEPTIC TANK
PARKING LOT LIGHT (1 HEAD)
PARKING LOT LIGHT (3 HEAD)
PARKING LOT LIGHT (2 HEAD)
DISTRIBUTION BOX
ROW RIGHT OF WAY
ESMT EASEMENT
D.&U.E. DRAINAGE AND UTILITY EASEMENT
FFE FINISH FLOOR ELEVATION
CMP CORRUGATED METAL PIPE
RCP REINFORCED CONCRETE PIPE
PVC POLYVINYL CHLORIDE PIPE
VCP VITRIFIED CLAY PIPE
HDPE HIGH DENSITY POLYETHYLENE PIPE
DIP DUCTILE IRON PIPE
SSD SUB SURFACE DRAIN PIPE
STM STORM
SAN SANITARY
STR STRUCTURE
CO CLEANOUT
NATIVE PLANTINGS AREA
AREAS
DRAINAGE PLAN LEGEND
UTILITIES
ABBREVIATIONS
OTHER
LINE TYPES
FLOW LINE
INDEX CONTOUR
INTERMEDIATE CONTOUR
SANITARY SEWER MAIN
STORM SEWER MAIN
UNDERGROUND GAS
UNDERGROUND WATER
AERIAL ELECTRIC
UNDERGROUND ELECTRIC
UNDERGROUND COMMUNICATIONS
AERIAL COMMUNICATIONS
OVERHEAD UTILITY
FORCE MAIN
G G G
W W
E(A) E(A)
E E E
C C C
C(A) C(A)
OHU OHU
FM FM
AERIAL FIBER OPTIC CABLEFO(A) FO(A)
UNDERGROUND FIBER OPTICFO FO
EMERGENCY FLOOD ROUTE
SANITARY SEWER LATERALSAN SAN
ROOF DRAINSTM STM
SUB SURFACE DRAIN
FLOW DIRECTION AND SLOPE
GENERAL DRAINAGE NOTES
1. THE CONTRACTOR SHALL ADHERE TO ALL TERMS AND CONDITIONS
AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL N.P.D.E.S.
PERMIT FOR STORMWATER DISCHARGE ASSOCIATED WITH
CONSTRUCTION ACTIVITIES AND STORMWATER POLLUTION
PREVENTION PLAN.
2. REFER TO THE INDIANA DEPARTMENT OF TRANSPORTATION (INDOT)
STANDARD SPECIFICATIONS, LATEST EDITION, FOR BASIC MATERIALS
AND CONSTRUCTION METHODS. THE SECTIONS BELOW FOR
VARIOUS ITEMS ARE TO CLARIFY THE INTENT OF THE
REQUIREMENTS FOR THIS PROJECT. PLEASE NOTE THAT OTHER
SECTIONS OF THE INDOT STANDARD SPECIFICATIONS MAY ALSO BE
APPLICABLE.
3. THE CONTRACTOR SHALL CONTACT APPLICABLE STATE
UNDERGROUND LOCATION SERVICE AT LEAST 72 HOURS PRIOR TO
ANY WORK AND SHALL CONTACT THE OWNER AND/OR ENGINEER
SHOULD UTILITIES APPEAR TO BE IN CONFLICT WITH THE PROPOSED
IMPROVEMENTS. IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH
CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE
PLANS.
4. THE PLANS SHOW THE LOCATION OF ALL KNOWN UTILITIES LOCATED
WITHIN THE LIMITS OF CONSTRUCTION ACCORDING TO INFORMATION
PROVIDED BY THE VARIOUS UTILITY COMPANIES, PREVIOUS
CONSTRUCTION PLANS AND AS EVIDENCED BY OBSERVATION OF
ABOVE GROUND CONDITIONS BY THE SURVEYOR. THE ACCURACY
OF THIS INFORMATION IS NOT GUARANTEED.
5. THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES TO
LOCATE MAINS, CONDUITS, SERVICE LINES, ETC. WITHIN THE
CONSTRUCTION LIMITS. THE LOCATION AND PROTECTION OF
UTILITY STRUCTURES, THEIR SUPPORT AND MAINTENANCE DURING
CONSTRUCTION (IN COOPERATION WITH APPLICABLE UTILITY
COMPANY) IS THE EXPRESSED RESPONSIBILITY OF THE
CONTRACTOR.
6. THE CONTRACTOR SHALL CONTACT ALL APPLICABLE UTILITIES AND
VERIFY ANY AND ALL FEES ASSOCIATED WITH THE INSTALLATION OF
ALL UTILITIES.
7. ALL CONSTRUCTION ON THIS SITE TO BE PERFORMED IN
COMPLIANCE WITH O.S.H.A. STANDARDS FOR WORKER SAFETY.
8. ANY PART OF STORM SEWER TRENCHES RUNNING UNDER OR WITHIN
5' OF PAVEMENT TO BE BACKFILLED WITH GRANULAR MATERIAL.
9. IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY LOCATION,
SIZE, AND ELEVATION OF EXISTING UTILITIES, STRUCTURES, PIPES,
PAVEMENTS, ETC. AS RELATED TO THEIR WORK. NOTIFY ENGINEER
OF ANY CONFLICT AND/OR DISCREPANCIES IN THE CONSTRUCTION
DOCUMENTS.
10. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL CLEARANCE BETWEEN
STORM / SANITARY SEWER SYSTEMS AND DOMESTIC/FIRE LINE
SERVICE. SANITARY SEWER LINE IN PROXIMITY OF WATER LINE
SHALL BE C900 WATER MAIN GRADE PVC.
11. CONTRACTOR TO INSTALL CONCRETE CRADLES WHEN THE
VERTICAL SEPARATION (AS MEASURED FROM THE EXTERIOR OF THE
PIPES) BETWEEN SANITARY SEWERS, WATER MAINS AND STORM
SEWERS IS 18" OR LESS.
12. IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING
CONSTRUCTION, IT SHALL BE THE CONTRACTORS RESPONSIBILITY
TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS
NECESSARY TO RETURN IT TO EXISTING CONDITIONS OR BETTER.
13. WHEN PERFORMING EXCAVATIONS DURING PERIODS OF WET
WEATHER, PROVIDE ADEQUATE DEWATERING, DRAINAGE AND
GROUND WATER MANAGEMENT TO CONTROL MOISTURE OF SOILS.
14. COMPACTED "B" BORROW BACK FILL REQUIRED OVER ALL UTILITIES
IN PAVED AREAS.
15. ALL UTILITY STRUCTURES IN PAVED AREAS SHALL BE FLUSH WITH
PAVEMENT AND SHALL HAVE TRAFFIC BEARING RING AND COVERS.
16. COORDINATE LOCATIONS AND CONNECTIONS OF BUILDING STORM
LINES WITH PLUMBING DRAWINGS.
17. FOLLOW ALL LOCAL AND STATE CODES IN REFERENCE TO STORM
SEWER INSTALLATION.
18. ALL EXISTING MANHOLE AND CATCH BASIN GRATES SHALL BE
ADJUSTED TO NEW FINISH GRADE ELEVATIONS.
19. EXISTING PIPES WITHIN CONSTRUCTION LIMITS ARE TO BE CLEANED
OUT TO REMOVE ALL SILT AND DEBRIS.
20. ALL STORM PIPE CONNECTIONS AT STRUCTURES SHALL BE
GROUTED TO ASSURE CONNECTION AT STRUCTURE IS WATERTIGHT.
21. ALL STORM SEWER STRUCTURES IN PAVED AREAS SHALL BE FLUSH
WITH PAVEMENT AND SHALL HAVE TRAFFIC BEARING RING AND
COVERS.
22. ALL STORM SEWER STRUCTURES SHALL HAVE A SMOOTH UNIFORM
POURED MORTAR CHANNEL FROM INVERT IN TO INVERT OUT.
23. NEW PIPES AND STRUCTURES WITHIN CONSTRUCTION LIMITS ARE
TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS PRIOR TO
FINAL TURNOVER TO THE OWNER.
24. ALL HDPE PIPE SHALL BE DUAL WALLED, HANCOR HQ, ADS N-12 PIPE
OR APPROVED EQUAL.
25. ALL FITTINGS AND ACCESSORIES INCLUDING BUT NOT LIMITED TO
END CAPS, CLEANOUTS, REDUCERS, ETC., SHALL BE OF HDPE
MATERIAL COMPARABLE WITH STORAGE PIPES.
26. PROVIDE BACKFILL WITH A MINIMUM OF 4" BEDDING MATERIAL OF #8
AGGREGATE COMPACTED IN 8" LIFTS TO 95% MAXIMUM DRY
DENSITY.
27. VERIFY EXISTING STORM INVERT ELEVATIONS PRIOR TO STARTING
NEW STORM SEWER CONNECTION.
28. THE PROPOSED STORM SEWER ON THIS SITE SHALL BE PRIVATE.
29. CONTRACTOR TO CONNECT BACK ANY FIELD TILES FOUND DURING
EXCAVATION AND MAINTAIN POSITIVE DRAINAGE.REVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, Indiana W19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
EXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJS
W
S
N
E E N GI N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil Engi neeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
CARMEL REQUIREMENTS
1. NO EARTH DISTURBING ACTIVITY MAY TAKE PLACE WITHOUT AN
APPROVED STORM WATER MANAGEMENT PERMIT.
2. DECORATIVE SIGNS, SPRINKLER SYSTEMS, TREES, LANDSCAPING
MOUNDS, FENCES, LIGHT POLES OR OTHER SUCH AMENITIES ARE NOT
PERMITTED WITHIN THE RIGHT-0F-WAY.
3. M.F.P.G. = MINIMUM FLOOD PROTECTION GRADE M.F.P.G. OF ALL
STRUCTURES FRONTING A POND OR OPEN DITCH SHALL BE NO LESS
THAN 2 FEET ABOVE ANY ADJACENT 100-YEAR LOCAL OR REGIONAL
FLOOD ELEVATIONS, WHICHEVER IS GREATER, FOR ALL WINDOWS,
DOORS, PIPE ENTRANCES, WINDOW WELLS, AND ANY OTHER
STRUCTURE MEMBER WHERE FLOOD WATERS CAN ENTER A BUILDING.
4. M.L.A.G. = LOWEST ADJACENT GRADE IS THE ELEVATION OF THE
LOWEST GRADE ADJACENT TO A STRUCTURE WHEN THE SOIL MEETS
THE FOUNDATION AROUND THE OUTSIDE OF THE STRUCTURE.
(INCLUDING STRUCTURAL MEMBERS SUCH AS BASEMENT WALKOUT,
PATIOS, DECKS, PORCHES, SUPPORT POST, OR PIERS, AND RIM OF
THE WINDOW WELL.
7
8
9
10
11
12
13
07/14/21
12" INV=824.08
OUTLET CONTROL STR
TC=827.50
12" RCP OUTLET INV=824.40
HYDRO INTERNATIONAL
FIRST DEFENSE HIGH CAPACITY
8' UNIT
TC=829.20
12" HDPE INV=824.08
12" RCP INV=824.08
DIVERSION STR
12" RCP INV=824.68
DIFFERENCE FROM INLET
INVERT SERVES AS WEIR
12" INV=824.02
12" HDPE INV=824.02
12" RCP INV=824.02
12" HDPE INV=824.06
C601DRAINAGE DETAILSW190582-C602 drainage detREQUIREMENTS FOR ALL STORM SEWER BENCHWALLS
BENCH WALLS SHALL BE SHAPED AND FORMED FOR A CLEAN TRANSITION WITH PROPER HYDRAULICS TO ALLOW THE
SMOOTH CONVEYANCE OF FLOWS THROUGH THE MANHOLE OR BOX INLET. THE BENCH WALL SHALL FORM A DEFINED
CHANNEL, TO A MINIMUM HEIGHT OF 80-PERCENT OF THE INSIDE DIAMETER OF THE INLET AND OUTLET PIPES TO FORM A
"U" SHAPED CHANNEL, CONSTRUCTED AT A MINIMUM ½-INCH PER FOOT SLOPE TO THE MANHOLE WALL.
WHERE A FLOW CHANNEL IS CONSTRUCTED AS AN INTEGRAL PART OF THE PRE-CAST BASE, IT SHALL BE SHAPED AND
FORMED AS DESCRIBED ABOVE, WITH THE EXCEPTION THAT THE BOTTOM OF THE FLOW CHANNEL MAY BE FORMED FROM
THE BOTTOM OF INLET AND OUTLET PIPES IF THE PIPE WALL THICKNESS IS NOT GREATER THAN ONE (1) INCH.
FOR CAST-IN-PLACE FLOW CHANNELS, THE BOTTOM INVERT OF ALL PIPES ENTERING A MANHOLE SHALL BE AT LEAST
THREE (3) INCHES ABOVE THE TOP OF THE BASE SLAB TO THE OUTLET INVERT SO THE FINISHED SEWER CHANNEL MAY BE
INSTALLED AND SHAPED.
FOR CONNECTIONS TO EXISTING STORM SEWER STRUCTURES, FLOW CHANNELS SHALL BE SHAPED, AS SPECIFIED HEREIN,
AS IF IT WERE A NEW MANHOLE OR BOX INLET STRUCTURE.
SPECIFICATIONS FOR ALL STORM SEWER CASTINGS
ALL STORM WATER INLETS AND CATCH BASINS SHALL HAVE THE WORDS "NO DUMPING, DRAINS TO STREAM", OR SIMILARLY
APPROVED MESSAGE, CAST IN RAISED OR RECESSED LETTERS AT A MINIMUM OF 1" IN HEIGHT. IN ADDITION, A SYMBOL OF A
FISH SHALL ALSO BE CAST WITH THE LETTERS.REVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, IndianaW19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
EXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJSENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
827.50828.05 828.05
NOTE: THE EMERGENCY OVERFLOW SHOULD HAVE A MINIMUM 0.50' OF FREEBOARD ABOVE
THE MAXIMUM ANTICIPATED FLOW THOUGH THE EMERGENCY OVERFLOW.
18" DEEP RIPRAP (1/3 CU.
FT. MIN. SIZE)
3:1 SLOPE EMERGENCY OVERFLOW
100 YEAR
ELEV.=827.42
3 :1 SLOPE
EMERGENCY OVERFLOW
(NO SCALE)
NOTE: GENERAL DETAIL. USE OFFLINE
8' UNIT. REFER TO OTHER DETAILS ON
THIS SHEET FOR FULL DETAILS.NATIVE PLANTINGS SIGN
PERMANENT SIGNS
SIZE: MINIMUM OF ONE SQUARE FOOT
MAXIMUM OF FOUR SQUARE FEET
DISTANCE: NO MORE THAN 500 FEET APART, WITH NO
LESS THAN 3 SIGNS PER POND. A SIGN MUST
BE PLACED AT ALL PUBLIC ACCESS AND
ENTRANCE ARES TO THE POND.
MATERIAL: PERMANENT MATERIAL, EITHER WOOD OR
METAL WITH BLADED EDGES.
TEXT: AT MINIMUM, MUST HAVE THE WORDS "NATIVE
PLANTINGS" AND ANY OTHER TEXT REQUIRED
BY THE CITY OF CARMEL.
COLORS: TO BE DETERMINED BY THE DEVELOPER.
NATIVE
PLANTINGS
DO NOT SPRAY
OR MOW
INDOT SEED MIXTURE "D" ON POND BANKS
THIS MIXTURE SHALL BE APPLIED AT THE RATE OF 1416 LB/AC. IT SHALL
CONSIST OF THE MATERIALS AND BE APPLIED AT THE RATES SHOWN
BELOW.
· Alkaligrass, Puccinellia distans, 3 oz/ac
· Bearded Strangletop, Leptochloa fascicularis, 3 oz/ac
· Creeping Bentgrass, Agrostis stolonifera, 2 lb/ac
· Fowl Manna Grass, Glyceria striata, 2 oz/ac
· Perennial Ryegrass, Lolium perenne, 5 lb/ac
· Red Fescue, Festuca rubra, 2 lb/ac
· Redtop, Agrostis gigantea, 1 lb/ac
· Rice Cut Grass, Leersia oryzoides, 2 oz/ac
· Virginia Wild Rye, Elymus virginicus, 5 lb/ac
· Wetland Carex Species, Carex spp., 3 oz/ac
· Wetland Rush Species, Juncus spp., 3 oz/ac
NATIVE PLANTING SEED MIX
(NO SCALE)
1" DIA. ORIFICE
ELEV=825.90
9" DIA. BYPASS ORIFICE
ELEV=824.50
0.9" DIA. ORIFICE
ELEV=824.50
12" DIA. OUTLET PIPE
ELEV=824.40
12" DIA. OUTLET PIPE
ELEV=824.40
NEENAH R-4215-C CASTING
OR APPROVED EQUAL
TOC=827.50
EXISTING 12" INV=824.08
12" HDPE INV=824.08
12" RCP INV=824.08
DIVERSION STR
12" RCP INV=824.68
DIFFERENCE FROM INLET INVERT
SERVES AS WEIR
12" RCP INV=824.08
INLET FROM POND RELEASE
EXISTING 12" INV=824.0812" HDPE INV=824.08
TO WQ UNIT
12" RCP INV=824.68
ELEV. DIFFERENCE CREATES WEIR
NEENAH R-4215-C CASTING
OR APPROVED EQUAL
TOC=828.50
DIVERSION STRUCTURE DETAIL #101
(NO SCALE)
OUTLET CONTROL STRUCTURE #102
(NO SCALE)
LEVEL SPREADER
07/14/21
REVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, IndianaW19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
EXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJSENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
C602DRAINAGE DETAILSEMERGENCY SPILLWAY
ELEV=827.50
PROPOSED RETAINING WALL.
HEIGHT VARIES ACROSS
LENGTH OF DRY BASIN.
EXISTING ASPHALT
PAVEMENT
NATIVE PLANTINGS, REFER
TO SEED MIX ON C601
ELEV=825.00
ELEV=824.50
ELEV=825.00
MATCH
EXISTING
ELEVATION
2' LEVEL SPREADER
DRY POND CROSS SECTION
(NO SCALE)
07/14/21
E
OHU OHU OHUOHU OHU OHU OHU OHU
OHU
OH U
OHU
OHU
OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU
G
W
W W
G
G
W
WEST C
A
R
M
E
L
D
R
I
V
E
GGG
PROPOSED BUILDING
20,121SF± PER FLOOR
F.F.E. = 829.85CSTM STM STM STM STM STMSTM STM STM STM STM STM STMESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS W W W W W W W W W W W W W WW W W WEE E E E E E E E EDRY POND
C603OVERFLOW ROUTING PLANW190582-C601 OVERFLOW ROUTING PLANREVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, IndianaW19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
EXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJS
W
S
N
E E N GI N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil Engi neeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
ELECTRICAL RISER
GUY ANCHOR
ELECTRIC JUNCTION BOX
ORNAMENTAL LIGHT
GENERATOR
STREET LIGHT
ELECTRIC MANHOLE
ELECTRIC OUTLET
UTILITY POLE
UTILITY POLE W/ TRANSFORMER
TRANSFORMER
COMMUNICATIONS JUNCTION BOX
COMMUNICATIONS MANHOLE
COMMUNICATIONS PEDESTAL
RIGHT OF WAY LINE
FENCE
GUARD RAIL
BOUNDARY LINE
FIRE DEPT HOOKUP
FIRE HYDRANT
POST INDICATOR VALVE
WATER METER
WATER VALVE
GAS METER
GAS VALVE
ELECTRIC METER
LIQUID PROPANE GAS TANK
MONITORING WELL
TRAFFIC SIGNAL POLE
TRAFFIC SIGNAL
BOLLARD
POST
SIGN
PARKING WHEEL STOP
DOWN SPOUT
ACCESSIBLE SPACE
GATE POST
COMMUNICATIONS RISER
STORM CLEANOUT
BEEHIVE INLET
CURB INLET
FLOOR DRAIN
ROUND INLET
SQUARE INLET
STORM MANHOLE
SANITARY SEWER CLEANOUT
LIFT STATION
SANITARY SEWER MANHOLE
SANITARY STUB MARKER
PARKING LOT LIGHT (1 HEAD)
ROW RIGHT OF WAY
ESMT EASEMENT
D.&U.E. DRAINAGE AND UTILITY EASEMENT
FFE FINISH FLOOR ELEVATION
TOC TOP OF CASTING
CMP CORRUGATED METAL PIPE
RCP REINFORCED CONCRETE PIPE
PVC POLYVINYL CHLORIDE PIPE
VCP VITRIFIED CLAY PIPE
HDPE HIGH DENSITY POLYETHYLENE PIPE
DIP DUCTILE IRON PIPE
SSD SUB SURFACE DRAIN PIPE
STM STORM
SAN SANITARY
STR STRUCTURE
CO CLEANOUT
DRAINAGE PLAN LEGEND
UTILITIES
ABBREVIATIONS
OTHER
LINE TYPES
FLOW LINE
INDEX CONTOUR
INTERMEDIATE CONTOUR
SANITARY SEWER MAIN
STORM SEWER MAIN
UNDERGROUND GAS
UNDERGROUND WATER
AERIAL ELECTRIC
UNDERGROUND ELECTRIC
UNDERGROUND COMMUNICATIONS
AERIAL COMMUNICATIONS
OVERHEAD UTILITY
FORCE MAIN
G G G
W W
E(A) E(A)
E E E
C C C
C(A) C(A)
OHU OHU
FM FM
AERIAL FIBER OPTIC CABLEFO(A) FO(A)
UNDERGROUND FIBER OPTICFO FO
EMERGENCY FLOOD ROUTE
SANITARY SEWER LATERALSAN SAN
ROOF DRAINSTM STM
SUB SURFACE DRAIN
FLOW DIRECTION AND SLOPE
D D LIMITS OF DISTURBANCE
100 YEAR CLOGGED INLET PONDING LIMITS
GENERAL NOTES
THE SITE DOES NOT LIE IN A SPECIAL FLOOD HAZARD
AREA AS ESTABLISHED BY THE FEDERAL
EMERGENCY MANAGEMENT AGENCY - NATIONAL
FLOOD INSURANCE PROGRAM, WHEN PLOTTED BY
SCALE ON FLOOD INSURANCE RATE MAP
#18057C0209 G, DATED NOVEMBER 19, 2014.
BENCHMARK DATA
BM G 54 -
ISHC BRONZE DISK ON A CONCRETE POST PROJECTING 1.5 FT. OUT OF THE GROUND ALONG
U.S. 31, 1.4 MILES NORTH OF I-465, 0.4 MILES SOUTH OF 116TH STREET, 100 FT. WEST OF
CENTERLINE OF SOUTH BOUND LANE OF U.S. 31, AND 2 FT. EAST OF R/W FENCE.
BM G 55 -
ISHC BRONZE DISK ON A CONCRETE POST PROJECTING 1.5 FT. OUT OF THE GROUND ALONG
U.S. 31, 2.6 MILES NORTH OF I-465, 0.7 MILES SOUTH OF 131ST STREET, 83 FT. WEST OF
CENTERLINE OF SOUTH BOUND LANE OF U.S. 31.
BM Y 42 -
CGS DISK IN CONCRETE SLAB ON THE EAST SIDE OF THE MONON TRAIL 218 FT. SOUTH OF 111TH
STREET.
M.F.P.G. = 828.90
M.L.A.G. = 828.85
07/14/21
C604OVERFLOW ROUTING PLANW190582-C601 OVERFLOW ROUTING PLANREVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, IndianaW19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
EXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJS
W
S
N
E ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
ELECTRICAL RISER
GUY ANCHOR
ELECTRIC JUNCTION BOX
ORNAMENTAL LIGHT
GENERATOR
STREET LIGHT
ELECTRIC MANHOLE
ELECTRIC OUTLET
UTILITY POLE
UTILITY POLE W/ TRANSFORMER
TRANSFORMER
COMMUNICATIONS JUNCTION BOX
COMMUNICATIONS MANHOLE
COMMUNICATIONS PEDESTAL
RIGHT OF WAY LINE
FENCE
GUARD RAIL
BOUNDARY LINE
FIRE DEPT HOOKUP
FIRE HYDRANT
POST INDICATOR VALVE
WATER METER
WATER VALVE
GAS METER
GAS VALVE
ELECTRIC METER
LIQUID PROPANE GAS TANK
MONITORING WELL
TRAFFIC SIGNAL POLE
TRAFFIC SIGNAL
BOLLARD
POST
SIGN
PARKING WHEEL STOP
DOWN SPOUT
ACCESSIBLE SPACE
GATE POST
COMMUNICATIONS RISER
STORM CLEANOUT
BEEHIVE INLET
CURB INLET
FLOOR DRAIN
ROUND INLET
SQUARE INLET
STORM MANHOLE
SANITARY SEWER CLEANOUT
LIFT STATION
SANITARY SEWER MANHOLE
SANITARY STUB MARKER
PARKING LOT LIGHT (1 HEAD)
ROW RIGHT OF WAY
ESMT EASEMENT
D.&U.E. DRAINAGE AND UTILITY EASEMENT
FFE FINISH FLOOR ELEVATION
TOC TOP OF CASTING
CMP CORRUGATED METAL PIPE
RCP REINFORCED CONCRETE PIPE
PVC POLYVINYL CHLORIDE PIPE
VCP VITRIFIED CLAY PIPE
HDPE HIGH DENSITY POLYETHYLENE PIPE
DIP DUCTILE IRON PIPE
SSD SUB SURFACE DRAIN PIPE
STM STORM
SAN SANITARY
STR STRUCTURE
CO CLEANOUT
DRAINAGE PLAN LEGEND
UTILITIES
ABBREVIATIONS
OTHER
LINE TYPES
FLOW LINE
INDEX CONTOUR
INTERMEDIATE CONTOUR
SANITARY SEWER MAIN
STORM SEWER MAIN
UNDERGROUND GAS
UNDERGROUND WATER
AERIAL ELECTRIC
UNDERGROUND ELECTRIC
UNDERGROUND COMMUNICATIONS
AERIAL COMMUNICATIONS
OVERHEAD UTILITY
FORCE MAIN
G G G
W W
E(A) E(A)
E E E
C C C
C(A) C(A)
OHU OHU
FM FM
AERIAL FIBER OPTIC CABLEFO(A) FO(A)
UNDERGROUND FIBER OPTICFO FO
EMERGENCY FLOOD ROUTE
SANITARY SEWER LATERALSAN SAN
ROOF DRAINSTM STM
SUB SURFACE DRAIN
FLOW DIRECTION AND SLOPE
D D LIMITS OF DISTURBANCE
GENERAL NOTES
THE SITE DOES NOT LIE IN A SPECIAL FLOOD HAZARD
AREA AS ESTABLISHED BY THE FEDERAL
EMERGENCY MANAGEMENT AGENCY - NATIONAL
FLOOD INSURANCE PROGRAM, WHEN PLOTTED BY
SCALE ON FLOOD INSURANCE RATE MAP
#18057C0209 G, DATED NOVEMBER 19, 2014.
BENCHMARK DATA
BM G 54 -
ISHC BRONZE DISK ON A CONCRETE POST PROJECTING 1.5 FT. OUT OF THE GROUND ALONG
U.S. 31, 1.4 MILES NORTH OF I-465, 0.4 MILES SOUTH OF 116TH STREET, 100 FT. WEST OF
CENTERLINE OF SOUTH BOUND LANE OF U.S. 31, AND 2 FT. EAST OF R/W FENCE.
BM G 55 -
ISHC BRONZE DISK ON A CONCRETE POST PROJECTING 1.5 FT. OUT OF THE GROUND ALONG
U.S. 31, 2.6 MILES NORTH OF I-465, 0.7 MILES SOUTH OF 131ST STREET, 83 FT. WEST OF
CENTERLINE OF SOUTH BOUND LANE OF U.S. 31.
BM Y 42 -
CGS DISK IN CONCRETE SLAB ON THE EAST SIDE OF THE MONON TRAIL 218 FT. SOUTH OF 111TH
STREET.
07/14/21
E
OHUOHU OHUOHU OHU OHU OHU OHU
OHU
OHU
OHU
OHU
OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU
G
W
W W
G
G
W
WEST C
A
R
M
E
L
D
R
I
VE
GGG
CSTM STM STM STMSTM STM STM STM STM STM STM STMSTMESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS W W W W W W W W W W W W W WW W W WEE E E E E E E E EDRY POND
GENERAL UTILITY NOTES
1. THE CONTRACTOR SHALL CONTACT APPLICABLE STATE UNDERGROUND
LOCATION SERVICE AT LEAST 72 HOURS PRIOR TO ANY WORK AND SHALL
CONTACT THE OWNER AND/OR ENGINEER SHOULD UTILITIES APPEAR TO BE IN
CONFLICT WITH THE PROPOSED IMPROVEMENTS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES
WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
2. THE PLANS SHOW THE LOCATION OF ALL KNOWN UTILITIES LOCATED WITHIN THE
LIMITS OF CONSTRUCTION ACCORDING TO INFORMATION PROVIDED BY THE
VARIOUS UTILITY COMPANIES, PREVIOUS CONSTRUCTION PLANS AND AS
EVIDENCED BY OBSERVATION OF ABOVE GROUND CONDITIONS BY THE
SURVEYOR. THE ACCURACY OF THIS INFORMATION IS NOT GUARANTEED.
3. THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES TO LOCATE MAINS,
CONDUITS, SERVICE LINES, ETC. WITHIN THE CONSTRUCTION LIMITS. THE
LOCATION AND PROTECTION OF UTILITY STRUCTURES, THEIR SUPPORT AND
MAINTENANCE DURING CONSTRUCTION (IN COOPERATION WITH APPLICABLE
UTILITY COMPANY) IS THE EXPRESSED RESPONSIBILITY OF THE CONTRACTOR.
4. THE CONTRACTOR SHALL CONTACT ALL APPLICABLE UTILITIES AND VERIFY ANY
AND ALL FEES ASSOCIATED WITH THE INSTALLATION OF ALL UTILITIES.
5. ALL CONSTRUCTION ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH
O.S.H.A. STANDARDS FOR WORKER SAFETY.
6. ANY PART OF SANITARY OR STORM SEWER TRENCHES RUNNING UNDER OR
WITHIN 5' OF PAVEMENT TO BE BACKFILLED WITH GRANULAR MATERIAL.
7. IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY LOCATION, SIZE, AND
ELEVATION OF EXISTING UTILITIES, STRUCTURES, PIPES, PAVEMENTS, ETC. AS
RELATED TO THEIR WORK. NOTIFY ENGINEER OF ANY CONFLICT AND/OR
DISCREPANCIES IN THE CONSTRUCTION DOCUMENTS.
8. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL CLEARANCE BETWEEN STORM /
SANITARY SEWER SYSTEMS AND DOMESTIC/FIRE LINE SERVICE. SANITARY
SEWER LINE IN PROXIMITY OF WATER LINE SHALL BE C900 WATER MAIN GRADE
PVC.
9. CONTRACTOR TO INSTALL CONCRETE CRADLES WHEN THE VERTICAL
SEPARATION (AS MEASURED FROM THE EXTERIOR OF THE PIPES) BETWEEN
SANITARY SEWERS, WATER MAINS AND STORM SEWERS IS 18" OR LESS.
10. IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING
CONSTRUCTION, IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO REPAIR
AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO
EXISTING CONDITIONS OR BETTER.
11. WHEN PERFORMING EXCAVATIONS DURING PERIODS OF WET WEATHER,
PROVIDE ADEQUATE DEWATERING, DRAINAGE AND GROUND WATER
MANAGEMENT TO CONTROL MOISTURE OF SOILS.
12. COMPACTED "B" BORROW BACK FILL REQUIRED OVER ALL UTILITIES IN PAVED
AREAS.
13. ALL UTILITY STRUCTURES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT
AND SHALL HAVE TRAFFIC BEARING RING AND COVERS.
14. PROVIDE THRUST BLOCKS FOR ALL WATER LINE BENDS AND TEES, INCLUDING
TAP CONNECTION.
15. CONTRACTOR SHALL COORDINATE WITH WATER COMPANY FOR DOMESTIC AND
FIRE SERVICE. CONNECT TO BUILDING DOMESTIC AND FIRE LINE. COORDINATE
WITH PLUMBING DRAWINGS.
16. COORDINATE LOCATION OF ELECTRICAL AND COMMUNICATION LINES WITH
LOCAL UTILITIES.
17. COORDINATE LOCATION OF REQUIRED CONDUITS FOR ELECTRIC SERVICE, LIGHT
POLES, COMMUNICATION SERVICE AND IRRIGATION SYSTEM.
18. COORDINATE LOCATION AND SIZE OF GAS SERVICE CONNECTION AND
INSTALLATION OF SERVICE LINE AND METER WITH GAS COMPANY.
19. COORDINATE LOCATIONS AND CONNECTIONS OF BUILDING STORM LINES WITH
PLUMBING DRAWINGS.
20. FOLLOW ALL LOCAL AND STATE CODES IN REFERENCE TO DOMESTIC/FIRE LINE
INSTALLATION AND STORM SEWER / SANITARY SEWER INSTALLATION.
21. SANITARY SEWER LATERAL, WATER SERVICE, & ELECTRICAL/COMMUNICATION
CONDUITS SHALL BE GRANULAR BACKFILL FOR ENTIRE RUN.
22. ALL EXISTING MANHOLE AND CATCH BASIN GRATES, WATER OR GAS VALVES
SHALL BE ADJUSTED TO NEW FINISH GRADE ELEVATIONS.
UTILITY PLAN NOTES
SANITARY SEWER NOTES
CONNECT PROPOSED 6" SANITARY SEWER LATERAL TO EXISTING
SANITARY SEWER LATERAL. COORDINATE CONNECTION WITH MEP.
PROVIDE CLEANOUTS AS REQUIRED/SHOWN. VERIFY INVERTS ON
EXISTING LINE AND COORDINATE CONDITIONS WITH MEP. ADJUST AS
REQUIRED. ALL EXISTING CONNECTIONS MUST BE TELEVISED PRIOR
TO CONNECTING. CARMEL UTILITY INSPECTOR MUST BE ON SITE TO
WITNESS THE TELEVISING AND CONNECTIONS. CONTACT JASON
STEWART PRIOR TO PROCEEDING AT 317-518-5842
EXISTING 6" SANITARY SEWER LATERAL.
PROPOSED SANITARY LATERAL CLEANOUT TYPE 1 (IN LANDSCAPE
AREAS WITHIN 3' OF BUILDING). REFER TO DETAIL ON SHEET [C801].
INTERNAL FLOOR DRAIN LOCATION. FLOOR INVERT TO BE 15"+/-
UNDERSLAB. PROVIDE A 1% UNDERSLAB SLOPE TO THE NORTHWEST
CORNER OF THE BUILDING. INVERT AT THE NW CORNER TO BE
APPROXIMATE 5'± BELOW FINISH FLOOR
WATER SERVICE NOTES:
COORDINATE AND CONNECT 6" FIRE LINE TO EXISTING WATER MAIN
WITH A WET TAP. CONTACT CARMEL UTILITIES BEFOREHAND (STEVE
COOK 317-733-2849)
COORDINATE CONNECTION OF DOMESTIC SERVICE LINE AND FIRE
SERVICE LINE WITH PLUMBING DRAWINGS.
COORDINATE LOCATION AND CONNECTION OF DOMESTIC METER
WITH LOCAL SERVICE PROVIDER. 1 1/2" WATER METER SET W/
BACKFLOW PREVENTION INSIDE THE BUILDING REQUIRED.
EXISTING FIRE HYDRANT.
PROPOSED POST INDICATOR VALVE (PIV).
PROPOSED FIRE DEPARTMENT CONNECTION 5" STORZ/2.5" SIAMESE.
PROPOSED WATER VALVE.
PROPOSED 6" PVC FIRE SERVICE LINE.
PROPOSED 2" PE DOMESTIC SERVICE LINE
PROPOSED PRIVATE FIRE HYDRANT ASSEMBLY. MUST BE RED IN
COLOR FROM THE FACTORY. PROVIDE BOLLARD PROTECTION.
6" PVC LINE FOR THE FDC CONNECTION
ELECTRIC NOTES:
COORDINATE AND CONNECT BUILDING ELECTRICAL LINE FROM
SERVICE DROP LOCATION TO TRANSFORMER. COORDINATE
CONNECTION WITH POWER COMPANY AND ELECTRICAL DRAWINGS.
ADJUST AS REQUIRED. 2-4" EC CONDUITS TO BE INSTALLED WITH
PULL STRINGS.
COORDINATE WITH UTILITY PROVIDER IF A NEW TRANSFORMER IS
REQUIRED.
BUILDING ELECTRICAL LINE POINT OF CONNECTION. COORDINATE
CONNECTION WITH POWER COMPANY AND ELECTRICAL DRAWINGS.
ADJUST AS REQUIRED.
COMMUNICATION NOTES:
COORDINATE AND CONNECT BUILDING COMMUNICATION SERVICE
LINE(S) TO CONNECTION POINT AS SHOWN. ADJUST AS REQUIRED.
PROVIDE (3)-4" PVC CONDUIT TO BE INSTALLED WITH PULL STRINGS.
GAS SERVICE NOTES:
CONNECT PROPOSED GAS SERVICE TO EXISTING GAS LINE. REFER
TO PLUMBING DRAWINGS AND COORDINATE WITH SERVICE
PROVIDER.
PROPOSED GAS METER LOCATION. REFER TO PLUMBING DRAWINGS
AND COORDINATE WITH SERVICE PROVIDER.
W4
W2
W3
SS3
SS2
W1
E1
E2
C1
G1
SS1
W5
W6
W7
W8
W9
C800UTILITY PLANELECTRICAL RISER
GUY ANCHOR
ELECTRIC JUNCTION BOX
ORNAMENTAL LIGHT
GENERATOR
STREET LIGHT
ELECTRIC MANHOLE
ELECTRIC OUTLET
UTILITY POLE
UTILITY POLE W/ TRANSFORMER
TRANSFORMER
COMMUNICATIONS JUNCTION BOX
COMMUNICATIONS MANHOLE
COMMUNICATIONS PEDESTAL
RIGHT OF WAY LINE
FENCE
GUARD RAIL
BOUNDARY LINE
CISTERN
DRINKING FOUNTAIN
FIRE DEPT HOOKUP
FIRE HYDRANT
POST INDICATOR VALVE
CHILLED WATER MANHOLE
WATER MANHOLE
SPRINKLER CONTROL BOX
SPRINKLER CONTROL VALVE
SPRINKLER
SPIGOT
WELL HEAD
WATER METER
WATER VALVE
GAS METER
GAS VALVE
ELECTRIC METER
LIQUID PROPANE GAS TANK
MONITORING WELL
TRAFFIC SIGNAL POLE
TRAFFIC SIGNAL
BOLLARD
FLAG POLE
PARKING METER
POST
SIGN
PARKING WHEEL STOP
DOWN SPOUT
ACCESSIBLE SPACE
GATE POST
COMMUNICATIONS RISER
STORM CLEANOUT
BEEHIVE INLET
CURB INLET
FLOOR DRAIN
ROUND INLET
SQUARE INLET
STORM MANHOLE
SANITARY SEWER CLEANOUT
LIFT STATION
SANITARY SEWER MANHOLE
SANITARY STUB MARKER
SEPTIC TANK
PARKING LOT LIGHT (1 HEAD)
PARKING LOT LIGHT (3 HEAD)
PARKING LOT LIGHT (4 HEAD)
PARKING LOT LIGHT (2 HEAD)
HEAVY DUTY ASPHALT
CONCRETE PAVEMENT
DISTRIBUTION BOX
ROW RIGHT OF WAY
ESMT EASEMENT
D.&U.E. DRAINAGE AND UTILITY EASEMENT
FFE FINISH FLOOR ELEVATION
CMP CORRUGATED METAL PIPE
RCP REINFORCED CONCRETE PIPE
PVC POLYVINYL CHLORIDE PIPE
VCP VITRIFIED CLAY PIPE
HDPE HIGH DENSITY POLYETHYLENE PIPE
DIP DUCTILE IRON PIPE
SSD SUB SURFACE DRAIN PIPE
STM STORM
SAN SANITARY
STR STRUCTURE
CO CLEANOUT
STANDARD DUTY ASPHALT
PAVEMENT
UTILITY PLAN LEGEND
UTILITIES
ABBREVIATIONS
OTHER
LINE TYPES
FLOW LINE
SANITARY SEWER MAIN
STORM SEWER MAIN
UNDERGROUND GAS
UNDERGROUND WATER
AERIAL ELECTRIC
UNDERGROUND ELECTRIC
UNDERGROUND COMMUNICATIONS
AERIAL COMMUNICATIONS
OVERHEAD UTILITY
FORCE MAIN
G G G
W W
E(A) E(A)
E E E
C C C
C(A) C(A)
OHU OHU
FM FM
AERIAL FIBER OPTIC CABLEFO(A) FO(A)
UNDERGROUND FIBER OPTICFO FO
SANITARY SEWER LATERALSAN SAN
ROOF DRAINSTM STM
SUB SURFACE DRAIN
G2
E3
REVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, Indiana W19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
EXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJSW
S
N
E ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence.SM STEVEN SCOTT RUCKER, PE No. 11300279
08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJSW10
SS4
W11
07/14/21
(2) "B" BORROW OR EQUIV.
GRANULAR MATERIAL
COMPACTED TO 95%
STANDARD PROCTOR DENSITY
#8 CRUSHED STONE OR
APPROVED EQUIVALENT
CLASS I BEDDING MATERIAL
HAND TAMPED OR WALKED
INTO PLACE
TYPICAL BEDDING SECTION - PVC & HDPE
ALL BEDDING & INITIAL BACKFILL SHALL
BE INSTALLED IN 6" TO 12" BALANCED
LIFTS A MIN. 9" CLEARANCE SHALL BE
PROVIDED ON EACH SIDE OF THE
INSTALLED PIPE
Bc = OUTSIDE DIAMETER
D = INSIDE DIAMETER
D = DEPTH OF BEDDING
MATERIAL BELOW PIPE
(1) REGULAR BACKFILL
GREATER THAN 5' (1)
EDGE OF PAVEMENT,
CURB, GUTTER OR
SIMILAR STRUCTURE IN
THE PUBLIC
RIGHT-OF-WAY
MIN. 6" TOPSOIL TO ENSURE
GRASS GROWTH IF NOT UNDER
PAVEMENT
12" MIN.Bc
C801UTILITY PLAN DETAILSW190582-C801 util det(NO SCALE)4"REVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, IndianaW19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWEXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJSENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
07/14/21
C900SPECIFICATIONSW190582-C900 specEROSION CONTROL SPECIFICATIONS
1. THIS PLAN IS DESIGNED AS AN ATTEMPT TO PREVENT ANY AND ALL SEDIMENT FROM LEAVING THE
CONSTRUCTION SITE BY WAY OF EROSION. IF EROSION OF SEDIMENT FROM THE SITE IS TAKING
PLACE, THE CONTRACTOR AND/OR OWNER SHALL TAKE PREVENTATIVE ACTION IMMEDIATELY. THE
ENGINEER SHALL BE CONSULTED IN THE EVENT THIS HAPPENS.
2. TEMPORARY SEEDING WILL BE APPLIED TO ANY AREAS LEFT INACTIVE FOR 15 DAYS OR MORE.
3. PERMANENT SEEDING IS TO BE APPLIED IMMEDIATELY TO AREAS THAT HAVE ACHIEVED FINAL AND
FINISHED GRADE.
4. PRESERVE EXISTING VEGETATION ON THE SITE WHENEVER AND WHEREVER POSSIBLE TO PREVENT
TOPSOIL EROSION.
5. ALL SEDIMENT CAPTURING MEASURES SHALL BE IMPLEMENTED PRIOR TO THE DISTURBANCE OF THE
CONSTRUCTION AREA THEY ARE INTENDED TO SERVICE.
6. ALL EROSION CONTROL MEASURES PROPOSED ARE TO BE PROPERLY MAINTAINED TO CONTINUE
THEIR EFFECTIVENESS.
7. IF GRADING OCCURS DURING THE MONTHS OF DECEMBER, JANUARY OR FEBRUARY DORMANT
SEEDING PROCEDURES SHALL BE USED.
8. DURING DRY WEATHER, KEEP LAWNS WATERED WITH SPRINKLERS OR OTHER APPROVED METHODS.
RESEED ANY AREAS NOT GERMINATING OR DAMAGED AT INTERVALS AS MAY BE REQUIRED
ACCORDING TO SEASONAL CONDITION AND/OR CONSTRUCTION ACTIVITY. WATER GRASS AND
EXECUTE NECESSARY WEEDING UNTIL FULL STAND OF GRASS HAS BEEN OBTAINED.
9. THE IMPLEMENTATION AND MAINTENANCE OF THE EROSION CONTROL IS THE SOLE RESPONSIBILITY
OF THE CONTRACTOR AND/OR OWNER.
10. IT SHALL BE THE CONTRACTOR'S AND/OR OWNER'S RESPONSIBILITY TO MINIMIZE SEDIMENTATION
(FROM ON-SITE CONSTRUCTION ACTIVITIES) FROM BEING DEPOSITED ONTO ADJACENT PROPERTIES
AND RECEIVING STREAMS/DITCHES IN STRICT COMPLIANCE WITH "RULE 5" (327 IAC 15-5,
CONSTRUCTION ACTIVITY STORMWATER RUNOFF CONTROL). IT SHALL ALSO BE THE CONTRACTOR'S
AND/OR OWNER'S RESPONSIBILITY TO OBTAIN ANY APPROVALS REQUIRED FROM THE LOCAL
AUTHORITY AND TO SUBMIT A COMPLETE NOTICE OF INTENT LETTER TO THE OFFICE OF WATER
MANAGEMENT, INDIANA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT PRIOR TO ANY
CONSTRUCTION ACTIVITY..
11. FOR SEASONAL VARIATIONS - SEE SEASONAL SOIL PROTECTION CHART IN THESE PLANS.
EARTHWORK SPECIFICATIONS
1. SCOPE OF WORK
1.A. EXTENT: THE WORK REQUIRED UNDER THIS SECTION CONSISTS OF ALL EXCAVATING, FILLING,
ROUGH GRADING AND RELATED ITEMS NECESSARY TO COMPLETE THE WORK INDICATED ON THE
DRAWINGS AND DESCRIBED IN THE SPECIFICATIONS.
1.A.1. IN GENERAL THE ITEMS OF WORK TO BE PERFORMED UNDER THIS SECTION SHALL INCLUDE
CLEARING AND GRUBBING, REMOVAL OF TREES AND STUMPS (WHERE REQUIRED), PROTECTION
OF TREES TO REMAIN, STRIPPING AND STORAGE OF TOPSOIL, FILL, COMPACTION AND ROUGH
GRADING OF ENTIRE SITE AS INDICATED ON THE DRAWINGS.
1.A.2. EXCAVATED MATERIAL THAT IS SUITABLE MAY BE USED FOR FILLS. ALL UNSUITABLE MATERIALS
AND ALL SURPLUS EXCAVATED MATERIAL NOT REQUIRED SHALL BE REMOVED FROM THE SITE.
THE LOCATION OF DUMP AND LENGTH OF HAUL SHALL BE THE CONTRACTOR'S RESPONSIBILITY.
1.A.3. PROVIDE AND PLACE ANY ADDITIONAL FILL MATERIAL FROM OFF THE SITE AS MAY BE
NECESSARY TO PRODUCE THE GRADES REQUIRED. FILL OBTAINED FROM OFF SITE SHALL BE OF
KIND AND QUALITY AS SPECIFIED TO FILLS HEREIN AND THE SOURCE APPROVED BY THE
ENGINEER AND OWNER.
1.A.4. THE CONTRACTOR SHALL ACCEPT THE SITE AS HE FINDS IT AND SHALL REMOVE ALL TRASH,
RUBBISH AND DEBRIS FROM THE SITE PRIOR TO STARTING EXCAVATION.
1.B. WORK INCLUDED: THE FOLLOWING ITEMS OF RELATED WORK ARE SPECIFIED AND INCLUDED IN
OTHER SECTIONS OF THESE SPECIFICATIONS.
1.B.1. EXCAVATION, GRADING AND BACKFILLING FOR UTILITY LINES.
1.B.2. STORM DRAINAGE SYSTEMS.
1.B.3. SANITARY SEWER SYSTEMS.
1.B.4. WATER SUPPLY SYSTEMS.
1.B.5. DRIVES AND PAVING.
2. BENCHMARKS
2.A. MAINTAIN CAREFULLY ALL BENCHMARKS, MONUMENTS AND OTHER REFERENCE POINTS, IF
DISTURBED OR DESTROYED REPLACE AS DIRECTED BY ENGINEER.
3. PROTECTION OF TREES
3.A. GENERAL PROTECTION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF
TOPS, TRUNKS AND ROOTS OF EXISTING TREES ON THE PROJECT SITE THAT ARE TO REMAIN.
EXISTING TREES SUBJECT TO CONSTRUCTION DAMAGE SHALL BE BOXED, FENCED OR OTHERWISE
PROTECTED BEFORE ANY WORK IS STARTED, DO NOT STOCKPILE WITHIN BRANCH SPREAD.
REMOVE INTERFERING BRANCHES WITHOUT INJURY TO TRUNKS AND COVER SCARS WITH TREE
PAINT.
4. REMOVAL OF TREES
4.A. REMOVE ALL TREES AND STUMPS FROM AREA TO BE OCCUPIED BY ROAD AND SURFACED AREAS.
REMOVAL OF TREES OUTSIDE THESE AREAS SHALL ONLY BE DONE AS NOTED ON DRAWINGS OR
APPROVED BY THE OWNER.
4.B. ALL BRUSH, STUMPS, WOOD AND OTHER REFUSE FROM THE TREES SHALL BE REMOVED FROM SITE
OR BURNED WITH PROPER PERMITS (WHERE APPLICABLE).
5. STRIPPING OF TOPSOIL
5.A. REMOVE TOPSOIL TO A DEPTH OF 6 INCHES (OR MORE IF REQUIRED) FROM THE AREAS TO BE
OCCUPIED BY ROADS, WALKS, BUILDINGS, AND PARKING AREAS. PILE AND STORE TOPSOIL AT A
LOCATION WHERE IT WILL NOT INTERFERE WITH CONSTRUCTION OPERATIONS. TOPSOIL SHALL BE
REASONABLY FREE FROM SUBSOIL, DEBRIS AND STONES.
6. SITE GRADING
6.A. GRADES: DO ALL CUTTING, FILLING, COMPACTING OF FILLS AND ROUGH GRADING REQUIRED TO
BRING ENTIRE PROJECT AREA TO SUBGRADE AS SHOWN ON THE DRAWINGS. UNDERCUT OPEN
AREAS 4 INCHES FOR TOPSOIL.
6.B. ROUGH GRADING: THE TOLERANCE FOR PAVED AREAS SHALL NOT EXCEED 0.10 FEET ABOVE
ESTABLISHED SUBGRADE. ALL OTHER AREAS SHALL NOT EXCEED 0.10 FEET PLUS OR MINUS THE
ESTABLISHED GRADE. PROVIDE ROUNDING AT TOP AND BOTTOM OF BANKS AND OTHER BREAKS IN
GRADE. ALL OPEN AREAS SHALL BE GRADED A MINIMUM OF 0.5% AND A MAXIMUM OF 3:1 SLOPE.
6.C. SUBGRADE SHALL BE PROOFROLLED WITH SUITABLE EQUIPMENT AND ALL SPONGY AND
OTHERWISE UNSUITABLE MATERIAL SHALL BE REMOVED AND REPLACED WITH SUITABLE MATERIAL.
6.D. SUBGRADE FOR STREETS AND PAVED AREAS SHALL BE COMPACTED TO 95% OF MODIFIED
PROCTOR.
6.E. SEE PROJECT MANUAL AND SOILS REPORT FOR REQUIREMENTS REGARDING UNDERCUTTING AND
SUBGRADE PREPARATION FOR PAVEMENT.
6.F. ALL FILL MATERIAL SHALL BE FORMED FROM SOIL FREE OF DELETERIOUS MATERIAL. PRIOR TO
PLACEMENT OF FILL, A SAMPLE OF THE PROPOSED MATERIAL SHALL BE SUBMITTED TO THE SOILS
ENGINEER FOR APPROVAL. THE FILL MATERIAL SHALL BE PLACED IN LAYERS NOT TO EXCEED 8" IN
LOOSE THICKNESS AND SHALL BE SPREAD AND COMPACTED AT THE PROPER MOISTURE CONTENT.
6.G. ALL FILL MATERIAL IN AREAS OUTSIDE OF BUILDING AND PAVEMENT AREAS SHALL BE COMPACTED
LIGHTLY WITH EACH LIFT AND PROTECTED FORM EROSION. AREAS OF BUILDING CONSTRUCTION
SHALL HAVE SUITABLE FILL MATERIAL PLACED AND COMPACTED IN ACCORDANCE WITH THE SOILS
ENGINEER'S REPORT (MINIMUM 95% MODIFIED PROCTOR).
7. DISPOSITION OF UTILITIES
7.A. RULES AND REGULATIONS GOVERNING THE RESPECTIVE UTILITIES SHALL BE OBSERVED IN
EXECUTING ALL WORK UNDER THIS SECTION.
7.B. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY ALL EXISTING UTILITIES AND
CONDITIONS PERTAINING TO HIS PHASE OF THE WORK. IT SHALL ALSO BE THE CONTRACTORS
RESPONSIBILITY TO CONTACT THE OWNERS OF THE VARIOUS UTILITIES BEFORE WORK IS STARTED.
THE CONTRACTOR SHALL NOTIFY IN WRITING THE OWNERS OR THE ENGINEERS OF ANY CHANGES,
ERRORS OR OMISSIONS FOUND ON THESE PLANS OR IN THE FIELD BEFORE WORK IS STARTED OR
RESUMES.
7.C. WHERE ACTIVE UTILITIES ARE ENCOUNTERED BUT NOT SHOWN ON THE DRAWINGS, THE ENGINEER
SHALL BE ADVISED BEFORE WORK IS CONTINUED.
7.D. INACTIVE AND ABANDONED UTILITIES ENCOUNTERED IN EXCAVATING AND GRADING OPERATIONS
SHALL BE REPORTED TO THE ENGINEER. THEY SHALL BE REMOVED, PLUGGED OR CAPPED AS
DIRECTED BY THE ENGINEER.
8. SEEDING PREPARATION
8.A. SOLVE ANY SURFACE OR SUBSURFACE DRAINAGE PROBLEMS AND CONSTRUCT PERMANENT
EROSION CONTROL STRUCTURES.
8.B. REMOVE ALL ROCKS, ROOTS OR OTHER MATERIALS THAT MAY INTERFERE WITH SEEDBED
PREPARATION.
8.C. PERFORM THE MAJOR FILLING SHAPING AND SMOOTHING OF GULLIED OR SEVERELY ERODED
AREAS.
PAVING SPECIFICATIONS
1. SCOPE OF WORK
1.A. THE WORK REQUIRED UNDER THIS SECTION INCLUDES ALL EXTERIOR CONCRETE AND BITUMINOUS
PAVING AND RELATED ITEMS NECESSARY TO COMPLETE THE WORK INDICATED ON DRAWINGS AND
DESCRIBED IN THE SPECIFICATIONS, INCLUDING BUT NOT LIMITED TO: ALL DRIVES, PARKING AREAS
IN CONTRACT LIMITS CURBS AND GUTTERS SIDEWALKS AND CONCRETE SLABS, EXTERIOR STEPS
2. MATERIALS
2.A. CONCRETE: CONCRETE SHALL BE READY-MADE AND SHALL BE A MIX OF PROPORTIONED FINE AND
COARSE AGGREGATES WITH PORTLAND CEMENT AND WATER. MINIMUM CEMENT CONTENT SHALL
BE 6 BAGS PER CUBIC YARD OF CONCRETE AND MAXIMUM WATER CONTENT SHALL BE 5.5 U.S.
GALLONS PER SACK OF CEMENT, INCLUDING MOISTURE IN THE AGGREGATE. SLUMP FOR NORMAL
WEIGHT CONCRETE SHALL BE A MAXIMUM OF 4 INCHES AND A MINIMUM OF 2 INCHES. THE SLUMP
OF MACHINE PLACE CONCRETE SHALL BE NO LESS THAN 1-1/4 INCHES NOR MORE THAN 3 INCHES.
STANDARD TEST ASTM C0143 SHALL BE USED TO MEASURE SLUMP. MINIMUM COMPRESSIVE
STRENGTH OF CONCRETE AT 28 DAYS SHALL BE 4000 PSI. ALL EXTERIOR CONCRETE SHALL HAVE
AIR ENTRAINMENT OF 5% TO 8% BY VOLUME PER ASTM C0260. RETEMPERING OF DELIVERED
CONCRETE WILL NOT BE ALLOWED. CONCRETE SHALL BE COMPOSED OF:
2.A.1. PORTLAND CEMENT: CONFORMING TO ASTM C-150, TYPE IA OR TYPE IIIA.
2.A.2. AGGREGATES: CONFORMING TO ASTM C-33.
2.A.3. WATER: SHALL BE CLEAR AND FREE FROM INJURIOUS AMOUNTS OF OILS, ACIDS, ALKALIC
ORGANIC MATERIALS OR OTHER DELETERIOUS SUBSTANCES.
2.B. WELDED STEEL WIRE FABRIC: WHERE REQUIRED FOR CONCRETE REINFORCEMENT SHALL
CONFORM TO ASTM A185.
2.C. PRE MOLDED JOINT FILLER: SHALL BE NON-EXTRUDING TYPE MEETING ASTM D-544, EXCEPT THAT
PRE MOLDED JOINT FILLER USED IN CONCRETE WALK CONSTRUCTION MAY BE EITHER
NON-EXTRUDING OR RESILIENT.
2.D. BITUMINOUS PAVEMENT MATERIALS: ALL MATERIALS PROPOSED FOR THE CONSTRUCTION OF
BITUMINOUS PAVEMENTS SHALL COMPLY WITH THE INDIANA DEPARTMENT OF TRANSPORTATION
SPECIFICATIONS LATEST VERSION SHALL BE USED.
2.E. COMPACTED AGGREGATE SUB-BASE: SHALL BE CRUSHED STONE OR GRAVEL. CRUSHED GRAVEL
SHALL BE A MINIMUM OF 35% CRUSHED MATERIAL. FINES SHALL BE LIMITED TO A MAXIMUM OF 8%
OF THE TOTAL. MATERIAL SHALL BE FREE FROM AN EXCESS OF FLAT, ELONGATED, THINLY
LAMINATED SOFT OR DISINTEGRATED PIECES, AND SHALL BE FREE FROM FRAGMENTS COATED
WITH DIRT. COMPACTED AGGREGATE SHALL BE GRADED AS FOLLOWS: PER LATEST REVISIONS.
SIEVE SIZE % PASSING
1-1/2" 100
1" 80-100
3/4" 79-90
1/2" 55-80
#4 35-60
#8 25-50
#30 12-30
#200 5-10
3. APPLICATION
3.A. GRADING: DO ANY NECESSARY GRADING IN ADDITION TO THAT PERFORMED IN ACCORDANCE WITH
EARTHWORK SECTION, TO BRING SUB GRADES, AFTER FINAL COMPACTION, TO THE REQUIRED
GRADES AND SECTIONS FOR SITE IMPROVEMENT.
3.B. PREPARATION OF SUB-GRADE: REMOVE SPONGY AND OTHERWISE UNSUITABLE MATERIAL AND
REPLACE WITH STABLE MATERIAL. NO TRAFFIC WILL BE ALLOWED ON PREPARED SUB-GRADE
PRIOR TO PAVING.
3.C. COMPACTION OF SUB-GRADE: THE FIRST 6 INCHES BELOW THE SUB-GRADE SHALL BE COMPACTED
TO AT LEAST 100% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY THE PROVISIONS OF
AASHTO T-99. WATER SHALL BE PREVENTED FOR STANDING ON THE COMPACTED SUB-GRADE
3.D. UTILITY STRUCTURES: CHECK FOR CORRECT ELEVATION OF ALL MANHOLE COVERS, INLETS, VALVE
BOXES AND SIMILAR STRUCTURES LOCATED WITHIN AREAS TO BE PAVED AND MARK, OR HAVE
MADE ANY NECESSARY ADJUSTMENTS IN SUCH STRUCTURES.
3.E. PLACING CONCRETE:
3.E.1. SUBGRADE: PLACE CONCRETE ONLY ON A MOIST, COMPACTED SUBGRADE OF BASE FREE
FROM LOOSE MATERIAL. PLACE NO CONCRETE ON A MUDDY OR FROZEN SUBGRADE
3.E.2. FORMS: ALL FORMS SHALL BE FREE FROM WARP, TIGHT ENOUGH TO PREVENT LEAKAGE AND
SUBSTANTIAL ENOUGH TO MAINTAIN THEIR SHAPE AND POSITION WITHOUT SPRINGING OR
SETTING, WHEN CONCRETE IS PLACED. FORMS SHALL BE CLEAN AND SMOOTH IMMEDIATELY
BEFORE PLACING CONCRETE.
3.E.3. PLACING CONCRETE: CONCRETE SHALL BE DEPOSITED SO AS TO REQUIRE AS LITTLE HANDING
AS PRACTICABLE. WHEN CONCRETE IS TO BE PLACED AT AN ATMOSPHERIC TEMPERATURE OF
35 DEGREES F, OR LESS, PARAGRAPH 702.10 OF THE INDIANA DEPARTMENT OF
TRANSPORTATION SPECIFICATIONS, LATEST REVISION SHALL BE FOLLOWED.
3.F. CONCRETE CURB:
3.F.1. EXPANSION JOINTS: SHALL BE 1/2 INCH THICK PRE MOLDED AT ENDS OF ALL RETURNS AND A
MAXIMUM SPACING OF 100 FEET.
3.F.2. CONTRACTION JOINTS: UNLESS OTHERWISE PROVIDED, CONTRACTION JOINTS SHALL BE
JOINTS SPACED 10 FEET ON CENTER.
3.F.3. FINISH: TAMP AND SCREED CONCRETE AS SOON AS PLACED, AND FILL ANY HONEYCOMBED
PLACES, FINISH SQUARE CORNERS TO 1/4 INCH RADIUS AND OTHER CORNERS TO RADII
SHOWN.
3.G. CONCRETE WALKS AND EXTERIOR STEPS:
3.G.1. SLOPES: PROVIDE ¼ INCH PER FOOT CROSS SLOPE. MAKE ADJUSTMENTS IN SLOPES A WALK
INTERSECTIONS AS NECESSARY TO PROVIDE PROPER DRAINAGE.
3.G.2. DIMENSIONS: WALKS AND STEPS SHALL BE ONE COURSE CONSTRUCTION AND OF WIDTHS AND
DETAILS SHOWN ON THE DRAWINGS.
3.G.3. FINISH: SCREED CONCRETE AND TROWEL WITH A STEEL TROWEL TO A HARD DENSE SURFACE
AFTER SURFACE WATER HAS DISAPPEARED. APPLY MEDIUM BROOM FINISH AND SCRIBE
CONTROL JOINTS AT 6 FEET SPACING. PROVIDE ½ INCH EXPANSION JOINTS WHERE SIDEWALKS
INTERSECT, AND AT A MAXIMUM SPACING OF 48 FEET BETWEEN EXPANSION JOINTS.
3.H. CURING CONCRETE: EXCEPT AS OTHERWISE SPECIFIED, CURE ALL CONCRETE BY ONE OF THE
METHODS DESCRIBED IN SECTION 501.17 OF THE INDIANA DEPARTMENT OF TRANSPORTATION
SPECIFICATIONS, LATEST REVISION SHALL BE USED.
3.I. BITUMINOUS PAVEMENT: HOT ASPHALT CONCRETE (TYPE B OR C) PAVEMENT SHALL BE AS
SPECIFIED IN SECTION 401/402 OF THE INDIANA DEPARTMENT OF TRANSPORTATION
SPECIFICATIONS, LATEST REVISIONS SHALL BE USED. PAVING WILL NOT BE PERMITTED DURING
UNFAVORABLE WEATHER OR WHEN THE TEMPERATURE IS 40 DEGREES F. AND FALLING.
3.J. COMPACTED AGGREGATE SUB-BASE: THE THICKNESS SHOWN ON THE DRAWINGS IS THE MINIMUM
THICKNESS OF THE FULL COMPACTED SUB-BASE. COMPACTION SHALL BE ACCOMPLISHED BY
ROLLING WITH A SMOOTH WHEELED ROLLER WEIGHING 8 TO 10 TONS. COMPACT TO 95%
COMPACTION USING STANDARD TESTING PROCEDURES. ALONG CURBS, HEADERS AND WALLS AND
AT ALL PLACES NOT ACCESSIBLE TO THE ROLLER, THE AGGREGATE MATERIAL SHALL BE TAMPED
WITH MECHANICAL TAMPERS OR WITH APPROVED TAMPERS.
STORM SEWER SPECIFICATIONS
1. SCOPE OF WORK
1.A. THE WORK UNDER THIS SECTION INCLUDES ALL STORM SEWERS, STORM WATER INLETS, AND
RELATED ITEMS, INCLUDING EXCAVATING AND BACKFILLING, NECESSARY TO COMPLETE THE WORK
SHOWN ON THE DRAWINGS.
2. MATERIALS
2.A. STORM SEWERS:
2.A.1. REINFORCED CONCRETE SEWER PIPE SHALL CONFORM TO ASTM C-76 CLASS 3 LATEST REVISION
WITH JOINTS CONFORMING TO ASTM C-443 LATEST REVISION.
2.A.2. STORM SEWERS HANCOR "HIQ" PIPE AND ADS OR APPROVED EQUAL: WITH THE FOLLOWING
REQUIREMENTS:
2.A.2.a. 4 INCH THROUGH 10 INCH MEETING AASHTO M252 TYPE S. 12 INCH THROUGH 36 INCH MEETING
AASHTO M294 TYPE S.
2.A.2.b. GASKETS MEETING ASTM D1056 GRADE 2A2.
2.A.2.c. FITTINGS MEETING ASSHTO M252 OR AASHTO M294, MEETING ASTM D3350 CELL
CLASSIFICATION 324420C: OR ASTM D3350 TYPE III, CLASS C, CATEGORY 4, GRADE P33.
2.B. DRAINAGE STRUCTURES:
2.B.1. PRECAST REINFORCED CONCRETE DRAINAGE SECTIONS AND STEPS SHALL CONFORM TO ASTM
C-478 LATEST REVISION AND LATEST REVISION OF INDOT PRECAST STRUCTURE DETAILS.
2.B.2. CASTINGS SHALL BE OF UNIFORM QUALITY, FREE FROM BLOW HOLES, POROSITY, HARD SPOTS,
SHRINKAGE DISTORTION OR OTHER DEFECTS, THEY SHALL BE SMOOTH AND WELL CLEANED BY
SHOT BLASTING OR BY SOME OTHER APPROVED METHOD. THEY SHALL BE COATED WITH
ASPHALT PAINT WHICH SHALL RESULT IN A SMOOTH COATING. TOUGH AND TENACIOUS WHEN
COLD, NOT TACKY OR BRITTLE. THEY SHALL BE GRAY IRON MEETING ASTM A-48 LATEST
REVISION.
2.B.3. JOINTS - STRUCTURE SECTIONS SHALL BE JOINTED WITH RUBBER TYPE GASKETS, THE RUBBER
TYPE GASKETS SHALL MEET ASTM C-443 LATEST REVISION.
2.C. SUBDRAINS:
2.C.1. PERFORATED PLASTIC PIPE SUBDRAINS SHALL CONFORM TO ASTM D3034, SDR 35, ASTM D2729,
OR ASTM F405.
3. APPLICATION
3.A. PERMITS AND CODES: THE INTENT OF THIS SECTION OF THE SPECIFICATIONS IS THAT THE
CONTRACTOR'S BID ON THE WORK COVERED HEREIN SHALL BE BASED UPON THE DRAWINGS AND
SPECIFICATIONS BUT THAT THE WORK SHALL COMPLY WITH ALL, APPLICABLE CODES AN
REGULATIONS AS AMENDED BY ANY WAIVERS. CONTRACTOR SHALL FURNISH ALL BONDS
NECESSARY TO GET PERMITS FOR CUTS AND CONNECTIONS TO EXISTING SEWERS.
3.B. LOCAL STANDARDS: THE TERM "LOCAL STANDARDS" AS USED HEREIN MEANS THE STANDARDS OF
DESIGN AND CONSTRUCTION OF THE RESPECTIVE MUNICIPAL DEPARTMENT AND/OR UTILITY
COMPANY.
3.C. EXISTING IMPROVEMENTS: MAINTAIN IN OPERATING CONDITION ALL ACTIVE UTILITIES, SEWERS
AND OTHER DRAINS ENCOUNTERED IN THE SEWER INSTALLATION. REPAIR TO THE SATISFACTION
OF THE OWNER ANY DAMAGE TO EXISTING ACTIVE IMPROVEMENTS.
3.D. WORKMANSHIP: TO CONFORM TO ALL LOCAL, STATE AND NATIONAL CODES AND TO BE APPROVED
BY ALL LOCAL AND STATE AGENCIES HAVING JURISDICTION.
3.E. TRENCHING: LAY ALL PIPE IN OPEN TRENCHES, EXCEPT WHEN THE LOCAL AUTHORITY GIVE
WRITTEN PERMISSION FOR TUNNELING. OPEN THE TRENCH SUFFICIENTLY AHEAD OF PIPE LAYING
TO REVEAL ANY OBSTRUCTIONS. THE WIDTH OF THE TRENCH SHALL BE THE INSIDE PIPE DIAMETER
PLUS 24 INCHES FOR 12 INCHES ABOVE THE PIPE. SHEET AND BRACE TRENCH AS NECESSARY TO
PROTECT WORKMEN AND ADJACENT STRUCTURES. ALL TRENCHING TO COMPLY WITH
OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION STANDARDS. KEEP TRENCHES FREE FROM
WATER WHILE CONSTRUCTION IS IN PROGRESS. UNDER NO CIRCUMSTANCES LAY PIPE OR
APPURTENANCES IN STANDING WATER. CONDUCT THE DISCHARGE FORM TRENCH DEWATERING TO
DRAINS OR NATURAL DRAINAGE CHANNELS.
3.F. SPECIAL SUPPORTS: WHENEVER, IN THE OPINION OF THE ENGINEER, THE SOIL AT OR BELOW THE
PIPE GRADE IS UNSUITABLE FOR SUPPORTING SEWERS AND APPURTENANCES SPECIFIED IN THIS
SECTION, SUCH SPECIAL SUPPORT, IN ADDITION THOSE SHOWN OR SPECIFIED, SHALL BE PROVIDED
AS THE ENGINEER MAY DIRECT, AND THE CONTRACT WILL BE ADJUSTED.
3.G. BACKFILLING
3.G.1. RCP BACKFILLING: FOR DEPTH OF AT LEAST 12 INCHES ABOVE THE TOP OF THE PIPE, BACKFILL
WITH EARTH OR GRANULAR MATERIAL FREE FROM LARGE STONES, ROCK FRAGMENTS, ROOTS
OR SOD. TAMP THIS BACKFILL THOROUGHLY TAKING CARE NOT TO DISTURB THE PIPE. FOR THE
REMAINING TRENCH DEPTH, BACKFILL WITH EARTH OR GRANULAR MATERIAL CONTAINING
STONES OR ROCKS NOT LARGER THAN 4 INCHES. BACKFILL UNDER WALKS, PARKING AREAS,
DRIVEWAYS AND STREETS SHALL BE GRANULAR MATERIAL ONLY THOROUGHLY COMPACTED BY
APPROVED METHODS. TRENCHES PARALLEL TO AND WITHIN 5 FEET OF PAVED ROADWAYS
SHALL ALSO BE CONSTRUCTED WITH COMPACTED GRANULAR MATERIALS.
3.G.2. HDPE BACKFILLING: FOR DEPTH OF AT LEAST 12 INCHES ABOVE THE TOP OF THE PIPE, BACKFILL
WITH GRANULAR MATERIAL. COMPACT THIS BACKFILL THOROUGHLY TAKING CARE NOT TO
DISTURB THE PIPE. FOR THE REMAINING TRENCH DEPTH, BACKFILL WITH EARTH OR GRANULAR
MATERIAL CONTAINING STONES OR ROCKS NOT LARGER THAN 4 INCHES. BACKFILL UNDER
WALKS, PARKING AREAS, DRIVEWAYS AND STREETS SHALL BE GRANULAR MATERIAL ONLY
THOROUGHLY COMPACTED BY APPROVED METHODS. TRENCHES PARALLEL TO AND WITHIN 5
FEET OF PAVED ROADWAYS SHALL ALSO BE CONSTRUCTED WITH COMPACTED GRANULAR
MATERIALS.
3.H. SUBDRAINS: ALL SUBDRAINS ON SITE SHALL BE OF THE SIZE AS SHOWN AND SHALL BE PLACED AS
SHOWN ON THE PLANS. THEY SHALL BE CONSTRUCTED TO THE GRADES AS SHOWN ON THE PLANS.
3.I. UTILITIES: IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY ALL EXISTING
UTILITIES AND CONDITIONS PERTAINING TO HIS PHASE OF THE WORK. IT SHALL ALSO, BE THE
CONTRACTORS RESPONSIBILITY TO CONTACT THE OWNERS OF THE VARIOUS UTILITIES BEFORE
WORK IS STARTED. THE CONTRACTOR SHALL NOTIFY IN WRITING THE OWNERS OR THE ENGINEER
OF ANY CHANGES, ERRORS OR OMISSIONS FOUND ON THESE PLANS OR IN THE FIELD BEFORE
WORK IS STARTED OR RESUMED.
WATER LINE SPECIFICATIONS
1. SCOPE OF WORK
1.A. THE WORK REQUIRED UNDER THIS SECTION INCLUDES ALL COLD WATER
DISTRIBUTION LINES, VALVES, METER PITS, HYDRANTS, AND RELATED ITEMS
INCLUDING EXCAVATING AND BACKFILLING NECESSARY TO COMPLETE THE WORK
SHOWN ON THE DRAWINGS. THE END OF WATER SERVICE LINES SHALL BE
TIGHTLY PLUGGED OR CAPPED AT THE TERMINAL POINTS PENDING THE
CONNECTING TO ALL SUCH LINES OF THE BUILDING PIPING AS SPECIFIED IN THE
PLUMBING SPECIFICATIONS AND ARCHITECTURAL DRAWINGS.
2. MATERIALS
2.A. DUCTILE IRON (D.I.) PIPE: DUCTILE IRON PIPE SHALL BE CLASS 350 AND MEET
AWWA C-150 AND C-151 SPECIFICATIONS. JOINTS SHALL MEET AWWA C-111
SPECIFICATIONS. PIPE SHALL BE CEMENT LINED PER AWWA C-104 AND SHALL BE
COATED OUTSIDE WITH A BITUMINOUS COATING. D.I. FITTINGS SHALL BE CEMENT
LINED AND MEET AWWA C-110 SPECIFICATIONS (350 PSI). COMPACT D.I. FITTINGS
SHALL BE CEMENT LINED AND MEET AWWA C-153 SPECIFICATIONS (CLASS 53, 350
PSI)
2.B. POLYVINYL CHLORIDE (PVC) PIPE: PVC PIPE SHALL HAVE THE SAME OUTSIDE
DIAMETER AS DUCTILE IRON PIPE, HAVE A MINIMUM WALL THICKNESS OF DR-18
FOR PRESSURE CLASS 150 AND MEET AWWA C900 SPECIFICATIONS. JOINTS SHALL
BE SLIP-ON TYPE WITH INTEGRAL BELL AND SPIGOT.
2.C. POLYETHYLENE (HDPE) PIPE: HDPE PIPE SHALL MEET AWWA C901 AND C906
SPECIFICATIONS. PIPE (3"-24") SHALL HAVE A MINIMUM WALL THICKNESS OF SRD
11. HDPE FITTINGS SHALL HAVE SAME DR AS PIPE BEING INSTALLED.
2.D. COPPER TUBING: SHALL BE SEAMLESS, ANNEALED COPPER TUBING COMPLYING
WITH FEDERAL SPECIFICATION WW-T799. FITTINGS SHALL BE WROUGHT COPPER
OR CAST BRONZE WITH SOLDER JOINTS. SOLDER SHALL BE OF A COMPOSITION
RECOMMENDED BY THE MANUFACTURER OF THE FITTINGS.
2.E. FIRE HYDRANTS: SHALL COMPLY WITH AWWA SPECIFICATION C-502 AND SHALL
MEET LOCAL STANDARDS AND REQUIREMENTS, PARTICULARLY AS TO NOZZLE
DIAMETERS AND THREADS, DIRECTION OF OPENING AND DIMENSIONS OF
OPERATING AND CAP NUTS. FIRE HYDRANTS SHALL HAVE ONE PUMPER AND TWO
HOSE NOZZLES. A VALVE OPENING NOT LESS THAN 5 INCHES AND A 6 INCH INLET
CONNECTION. THE LENGTH OF THE HYDRANT BARREL SHALL BE DETERMINED BY
THE SPECIFIED DEPTH OF COVER OVER THE PIPE.
2.F. VALVES: ALL VALVES AND STOPS SHALL HAVE ENDS SUITED OR ADAPTERS SHALL
BE PROVIDED FOR THE PROPER INSTALLATION IN THE LINES IN WHICH THEY ARE
LOCATED. VALVES SHALL MEET LOCAL STANDARDS OR IN THE ABSENCE OF SUCH
STANDARDS, THE FOLLOWING REQUIREMENTS.
2.F.1. VALVES IN CAST IRON PIPE SHALL BE IRON BODY, BRONZE MOUNTED, DISC
GATE VALVES CONFORMING TO AWWA SPECIFICATION C-500. THEY SHALL
OPEN IN THE SAME DIRECTION AS THOSE USED IN THE LOCAL WATERWORKS
SYSTEM. VALVE STEMS SHALL TERMINATE IN 2 INCH WRENCH NUTS. FURNISH
TWO (2) KEYS.
2.F.2. VALVES IN COPPER PIPE SHALL BE STANDARD BRASS BODY, ROUND-WAY,
GROUND-KEY STOPS, WITH T HEADS. FURNISH TWO (2) KEYS.
2.G. VALVE BOXES: SHALL MEET LOCAL STANDARDS OR IN THE ABSENCE OF SUCH,
SHALL COMPLY WITH THE FOLLOWING REQUIREMENTS:
2.G.1. FOR IRON BODY VALVES, BOXES SHALL BE APPROVED STANDARD
BUFFALO-TYPE CAST IRON, ADJUSTABLE SHAFT BOXES, HAVING A MINIMUM
SHAFT DIAMETER OF 5-1/4 INCHES.
2.G.2. FOR BRASS BODY VALVES (STOPS) BOXES SHALL BE APPROVED STANDARD
CAST IRON EXTENSION SERVICE BOXES, HAVING A MINIMUM DIAMETER OF 2-1/2
INCHES AND HAVING LID HELD IN PLACE BY A BRASS OR BRONZE BOLT. THE
CASTINGS SHALL BE COATED WITH TWO COATS OF COAL-TAR PITCH VARNISH.
FURNISH TWO (2) KEYS FOR BOLT IN LIDS.
3. APPLICATION:
3.A. PERMITS AND CODES: THE INTENT OF THIS SECTION OF THE SPECIFICATIONS IS
THAT THE CONTRACTOR'S BID ON THE WORK COVERED HEREIN SHALL BE BASED
UPON THE DRAWINGS AND SPECIFICATIONS BUT THAT THE WORK SHALL COMPLY
WITH ALL APPLICABLE CODES AND REGULATIONS. CONTRACTOR SHALL FURNISH
ALL NECESSARY BONDS TO GET PERMITS FOR CUTS AND CONNECTIONS.
3.B. EXISTING IMPROVEMENTS: MAINTAIN IN OPERATING CONDITION ALL ACTIVE
UTILITIES AND SEWERS AND OTHER PIPE SYSTEM THAT MAY BE ENCOUNTERED.
3.C. TRENCHING: LAY ALL PIPE IN OPEN TRENCHES, EXCEPT WHEN LOCAL AUTHORITY
GIVES WRITTEN PERMISSION FOR TUNNELING. PROVIDE SEPARATE TRENCH FOR
THE WATER LINE AT LEAST 10 FEET HORIZONTALLY FROM ANY SANITARY SEWER.
IN LOCATIONS WHERE SEPARATE TRENCHES FOR SEWER AND WATER LINES ARE
IMPRACTICABLE, LAY THE WATER PIPE ON A SOLID SHELF AT LEAST 18 INCHES
ABOVE THE TOP OF THE SEWER.
3.D. WIDTH OF TRENCH: EXCAVATE TRENCHES 12 INCHES EACH SIDE OF THE PIPE
FOR PROPER INSTALLATION OF PIPE.
3.E. SHEETING AND BRACING: SHEET AND BRACE TRENCHES AS NECESSARY TO
PROTECT WORKMEN AND ADJACENT STRUCTURES. ALL TRENCHING SHALL
COMPLY WITH THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION
STANDARDS.
3.F. WATER REMOVAL: KEEP TRENCHES FREE FROM WATER WHILE CONSTRUCTION
THEREIN IS IN PROGRESS. UNDER NO CIRCUMSTANCES LAY PIPE OR
APPURTENANCES IN STANDING WATER. CONDUCT THE DISCHARGE FROM TRENCH
DEWATERING TO DRAINS, OR NATURAL DRAINAGE CHANNELS.
3.G. GRADING TRENCH BOTTOMS: THE BOTTOM QUADRANT OF THE PIPE SHALL BE
FULLY AND UNIFORMLY SUPPORTED. THE FULL LOAD SHALL REST ON THE
BARREL OF THE PIPE. THE TRENCH MAY BE EXCAVATED TO A DEPTH OF 4 INCHES
OR MORE BELOW FINAL GRADE WITH SAND, CRUSHED STONE OR GRAVEL
BACKFILL TO BRING IT BACK TO PIPE LAYING GRADE. FOR A DEPTH OF AT LEAST
12 INCHES ABOVE THE TOP OF THE PIPE BACKFILL WITH EARTH OR GRANULAR
MATERIAL FREE FROM LARGE STONES, ROOTS OR FROZEN CLOGS. TAMP THIS
BACKFILL THOROUGHLY TAKING CARE NOT TO DISTURB THE PIPE. BACKFILL
UNDER WALKS, PARKING AREAS DRIVEWAYS AND STREETS WITH GRANULAR
MATERIAL ONLY AND TAMP THOROUGHLY, BY APPROVED METHODS. TRENCHES
PARALLEL TO AND WITHIN 10 FEET OF PAVED ROADWAYS SHALL ALSO BE
CONSTRUCTED WITH COMPACTED GRANULAR MATERIAL.
3.H. TESTS: BEFORE JOINTS ARE COVERED, FILL THE PIPING WITH WATER, OPENING
HYDRANTS OR OTHER OUTLETS TO EXPEL AIR. TEST THE PIPING FOR LEAKAGE AS
REQUIRED BY THE LOCAL UTILITY. INSPECT ALL JOINTS FOR LEAKAGE AND
REMEDY ANY LEAKS. UPON COMPLETION OF THE WATER LINES, FLUSH OUT THE
SYSTEM UNTIL THE WATER RUNS CLEAR. AS SOON AS THE SYSTEM HAS BEEN
FLUSHED OUT, IT SHALL BE STERILIZED IN ACCORDANCE WITH THE
REQUIREMENTS OF THE LOCAL UTILITY.
3.I. IF A HORIZONTAL DISTANCE OF 10 FEET CANNOT BE MAINTAINED BETWEEN THE
WATER LINE AND THE SANITARY SEWER LINE, THE SEWER MUST BE
CONSTRUCTED OF WATER WORKS GRADE DUCTILE IRON OR PVC PIPE WITH
MECHANICAL JOINTS WITHIN 10' OF EITHER SIDE THE WATER LINE.
3.J. UTILITIES: IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY
ALL EXISTING UTILITIES AND CONDITIONS PERTAINING TO HIS PHASE OF THE
WORK. IT SHALL ALSO BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE
OWNERS OF THE VARIOUS UTILITIES BEFORE WORK IS STARTED. THE
CONTRACTOR SHALL NOTIFY IN WRITING THE OWNERS OR THE ENGINEER OF ANY
CHANGES, ERRORS OR OMISSIONS FOUND ON THESE PLANS OR IN THE FIELD
BEFORE WORK IS STARTED OR RESUMED.
3.K. NEW WATER LINE CONSTRUCTION: CONTRACTOR TO RECORD DIMENSION OF
EACH WATER STUB AND VALVES FROM NEAREST FIRE HYDRANT MEASURED
ALONG WATER MAIN. THE LOCATIONS OF HYDRANTS AND WATER VALVES, ALONG
WITH ANY OTHER CONSTRUCTION CHANGES ARE TO BE INCORPORATED ON THE
ORIGINAL CONSTRUCTION DRAWINGS AND "RECORD DRAWING" PRINTS SHALL BE
SUBMITTED TO THE LOCAL UTILITY AS SOON AFTER COMPLETION OF
CONSTRUCTION AS POSSIBLE.
NOTE: THE ENGINEER AND/OR OWNER DISCLAIM ANY
ROLE IN THE CONSTRUCTION MEANS AND METHODS
ASSOCIATED WITH THE PROJECT AS SET FORTH IN
THESE PLANS.
PAVEMENT MARKING SPECIFICATIONS
1. SUMMARY
1.A. SECTION INCLUDES:
1.A.1. PAINTING AND MARKING OF PAVEMENTS.
1.B. REFERENCES
1.B.1. THE PUBLICATIONS LISTED BELOW FORM A PART OF THIS SPECIFICATION TO THE EXTENT
REFERENCED. PUBLICATIONS ARE REFERENCED WITHIN THE TEXT BY THE BASIC DESIGNATION
ONLY.
1.B.2. AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION (AASHTO):
1.B.2.a. AASHTO M247 - GLASS BEADS USED IN TRAFFIC PAINTS
1.B.2.b. AASHTO M248 - READY-MIXED WHITE AND YELLOW TRAFFIC PAINTS
1.B.3. ASTM INTERNATIONAL (ASTM):
1.B.3.a. ASTM D4414 - STANDARD PRACTICE FOR MEASUREMENT OF WET FILM THICKNESS BY
NOTCHED GAUGES.
1.B.4. FEDERAL SPECIFICATIONS (FS):
1.B.4.a. FS A-A-2886 - PAINT, TRAFFIC, SOLVENT BASED (SUPERSEDES FS TT-P-85 AND FS TT-P-115,
TYPE I)
1.B.4.b. FS TT-B-1325 - BEADS (GLASS SPHERES) RETRO-REFLECTIVE
1.B.4.c. FS TT-P-1952 - PAINT, TRAFFIC AND AIRFIELD MARKING, WATERBORNE
1.C. PROJECT CONDITIONS
1.C.1. MAINTAIN ACCESS FOR VEHICULAR AND PEDESTRIAN TRAFFIC AS REQUIRED FOR OTHER
CONSTRUCTION ACTIVITIES. UTILIZE FLAGMEN, BARRICADES, WARNING SIGNS, AND WARNING
LIGHTS AS REQUIRED.
1.D. QUALITY ASSURANCE
1.D.1. USE TRAINED AND EXPERIENCED PERSONNEL IN APPLYING THE PRODUCTS AND OPERATING THE
EQUIPMENT REQUIRED FOR PROPERLY PERFORMED WORK.
2. PRODUCTS
2.A. MATERIALS
2.A.1. PAINT SHALL BE WATERBORNE OR SOLVENT BORNE, COLORS AS SHOWN OR SPECIFIED HEREIN.
PAVEMENT MARKING PAINTS SHALL COMPLY WITH APPLICABLE STATE AND LOCAL LAWS
ENACTED TO ENSURE COMPLIANCE WITH FEDERAL CLEAN AIR STANDARDS. PAINT MATERIALS
SHALL CONFORM TO THE RESTRICTIONS OF THE LOCAL AIR POLLUTION CONTROL DISTRICT.
2.A.2. WATERBORNE PAINT: PAINTS SHALL CONFORM TO FS TT-P-1952.
2.A.3. SOLVENT BORNE PAINT: PAINT SHALL CONFORM TO FS A-A-2886 OR AASHTO M248. PAINT SHALL
BE NON_BLEEDING, QUICK_DRYING, AND ALKYD PETROLEUM BASE PAINT SUITABLE FOR
TRAFFIC_BEARING SURFACE AND BE MIXED IN ACCORDANCE WITH MANUFACTURE'S
INSTRUCTIONS BEFORE APPLICATION FOR COLORS WHITE, YELLOW, BLUE, AND RED.
2.A.4. GLASS BEADS: AASHTO M 247, TYPE 1 OR FS TT-B-1325, TYPE 1, GRADATION A.
3. EXECUTION
3.A. EXAMINATION
3.A.1. EXAMINE THE WORK AREA AND CORRECT CONDITIONS DETRIMENTAL TO TIMELY AND PROPER
COMPLETION OF THE WORK. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE
CORRECTED.
3.B. PREPARATION
3.B.1. SWEEP AND CLEAN SURFACE TO ELIMINATE LOOSE MATERIAL AND DUST.
3.B.2. WHERE EXISTING PAVEMENT MARKINGS ARE INDICATED ON CONSTRUCTION DRAWINGS TO BE
REMOVED OR WOULD INTERFERE WITH ADHESION OF NEW PAINT, A MOTORIZED ABRASIVE
DEVICE SHALL BE USED TO REMOVE THE MARKINGS. EQUIPMENT EMPLOYED SHALL NOT
DAMAGE EXISTING PAVING OR CREATE SURFACES HAZARDOUS TO VEHICLE OR PEDESTRIAN
TRAFFIC. WITHIN PUBLIC RIGHTS-OF-WAY, APPROPRIATE GOVERNING AUTHORITY SHALL
APPROVE METHOD OF MARKING REMOVAL.
3.B.3. NEW PAVEMENT SURFACES SHALL BE ALLOWED TO CURE FOR NOT LESS THAN 30 DAYS BEFORE
APPLICATION OF MARKING MATERIALS.
3.C. APPLICATION
3.C.1. APPLY TWO COATS OF SAME COLOR OF PAINT AS SPECIFIED BELOW, AT MANUFACTURER'S
RECOMMENDED RATE, WITHOUT ADDITION OF THINNER, WITH MAXIMUM OF 100 SQUARE FEET
PER GALLON OR AS REQUIRED TO PROVIDE A MINIMUM WET FILM THICKNESS OF 15 MILS AND
DRY FILM THICKNESS OF 7 ½ MILS PER COAT. PAINT SHALL BE APPLIED FOR A TOTAL DRY FILM
THICKNESS OF 15 MILS. APPLY WITH MECHANICAL EQUIPMENT TO PRODUCE UNIFORM STRAIGHT
EDGES. AT SIDEWALK CURBS AND CROSSWALKS, USE STRAIGHTEDGE TO ENSURE UNIFORM,
CLEAN, AND STRAIGHT STRIPE.
3.C.2. INSTALL PAVEMENT MARKINGS ACCORDING TO MANUFACTURER'S RECOMMENDED PROCEDURES
FOR THE SPECIFIED MATERIAL.
3.C.3. FOLLOWING ITEMS SHALL BE PAINTED WITH COLORS NOTED BELOW:
3.C.3.a. PEDESTRIAN CROSSWALKS: WHITE
3.C.3.b. EXTERIOR SIDEWALK CURBS AND GUARD POSTS: YELLOW
3.C.3.c. FIRE LANES: RED OR PER LOCAL CODE
3.C.3.d. LANE STRIPING WHERE SEPARATING TRAFFIC MOVING IN OPPOSITE DIRECTIONS: YELLOW
3.C.3.e. LANE STRIPING WHERE SEPARATING TRAFFIC MOVING IN THE SAME DIRECTION: WHITE
3.C.3.f. ADA SYMBOLS: BLUE OR PER LOCAL CODE
3.C.3.g. ADA PARKING SPACE MARKINGS AS SHOWN ON THE DRAWINGS.
3.C.3.h. PARKING STALL STRIPING: WHITE, UNLESS OTHERWISE NOTED ON CONSTRUCTION
DRAWINGS
3.C.4. APPLY GLASS BEADS AT PEDESTRIAN CROSSWALK STRIPING AND AT LANE STRIPING AND
ARROWS AT DRIVEWAYS CONNECTING TO PUBLIC STREETS. BROADCAST GLASS BEADS
UNIFORMLY INTO WET MARKINGS AT A RATE OF 6 LB/GAL.
3.D. FIELD QUALITY CONTROL
3.D.1. INSPECTION: AFTER THE PAINT HAS THOROUGHLY DRIED, VISUALLY INSPECT THE ENTIRE
APPLICATION AND TOUCH UP AS REQUIRED TO PROVIDE CLEAN, STRAIGHT LINES AND SURFACES
THROUGHOUT.
3.D.2. TESTING: TESTING OF WET FILM THICKNESS SHALL BE PERFORMED A MINIMUM OF TWO TIMES
ON EACH PARKING ROW (INCLUDING STRIPED ISLANDS) AND PEDESTRIAN CROSS WALKS, AND A
MINIMUM OF ONE TEST ON EACH LANE/ALIGNMENT STRIPING. AT LEAST ONE TEST SHALL BE
PERFORMED AFTER REFILLING PAINT STRIPING MACHINE, CHANGING OPERATORS OF STRIPING
MACHINE, AND CHANGING PAINT TYPES, BRANDS, ETC. THIS SHALL BE PERFORMED IN ADDITION
TO THE TESTING STATED ABOVE. THESE TESTS SHALL BE PERFORMED ON EACH COAT APPLIED.
TESTING SHALL BE PERFORMED IN ACCORDANCE WITH ASTM D4414.
3.E. CLEANING
3.E.1. WASTE MATERIALS SHALL BE REMOVED AT THE END OF EACH WORKDAY. UPON COMPLETION OF
THE WORK, ALL CONTAINERS AND DEBRIS SHALL BE REMOVED FROM THE SITE. PAINT SPOTS
UPON ADJACENT SURFACES SHALL BE CAREFULLY REMOVED BY APPROVED PROCEDURES THAT
WILL NOT DAMAGE THE SURFACES AND THE ENTIRE JOB LEFT CLEAN AND ACCEPTABLE.REVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, Indiana W19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
EXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJSENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
-NOTE-
PAVING IN THE RIGHT-OF-WAY TO CONFORM TO THE CITY
SPECIFICATIONS. ALL CURBS MUST CONFORM TO CITY'S CURBING
SPECIFICATIONS.
07/14/21
C901SPECIFICATIONSW190582-C900 specREVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, Indiana W19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
EXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJSENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
”
07/14/21
C902SPECIFICATIONSW190582-C900 specNOTE: THE ENGINEER AND/OR OWNER DISCLAIM ANY
ROLE IN THE CONSTRUCTION MEANS AND METHODS
ASSOCIATED WITH THE PROJECT AS SET FORTH IN
THESE PLANS.
SANITARY SEWAGE SPECIFICATIONS
PART 1 - GENERAL
1. SUMMARY
1.A. SECTION INCLUDES:
1.A.1. SANITARY SEWER DRAINAGE PIPING, FITTINGS, ACCESSORIES, CLEANOUTS,
AND BEDDING.
1.A.2. CONNECTION OF SITE SANITARY SEWER SYSTEM TO MUNICIPAL SANITARY
SEWER SYSTEMS.
1.B. RELATED REQUIREMENTS:
1.A.1. EARTHWORK: TRENCHING, BACKFILL, AND COMPACTION FOR UTILITIES
1.A.2. SEWER MANHOLES, FRAMES, AND COVERS
1.A.3. CAST-IN-PLACE STRUCTURAL CONCRETE
2. REFERENCES
2.A. THE PUBLICATIONS LISTED BELOW FORM A PART OF THIS SPECIFICATION TO THE
EXTENT REFERENCED. PUBLICATIONS ARE REFERENCED WITHIN THE TEXT BY
THE BASIC DESIGNATION ONLY.
2.B. ASTM INTERNATIONAL (ASTM):
2.B.1. ASTM A74 - CAST IRON SOIL PIPE AND FITTINGS
2.B.2. ASTM A746 - DUCTILE IRON GRAVITY SEWER PIPE
2.B.3. ASTM C425 - COMPRESSION JOINTS FOR VITRIFIED CLAY PIPE AND FITTINGS
2.B.4. ASTM C564 - RUBBER GASKETS FOR CAST IRON SOIL PIPE AND FITTINGS
2.B.5. ASTM C700 - VITRIFIED CLAY PIPE, EXTRA STRENGTH, STANDARD STRENGTH,
AND PERFORATED
2.B.6. ASTM D2241 - POLY (VINYL CHLORIDE) (PVC) PRESSURE-RATED PIPE (SDR
SERIES)
2.B.7. ASTM D2657 - HEAT-JOINING POLYOLEFIN PIPE AND FITTINGS
2.B.8. ASTM D3034 - TYPE PSM POLY (VINYL CHLORIDE) (PVC) SEWER PIPE AND
FITTINGS
2.B.9. ASTM D3035 - POLYETHYLENE (PE) PLASTIC PIPE USING FLEXIBLE
ELASTOMERIC SEALS
2.B.10. ASTM D3139 - JOINTS FOR PLASTIC PRESSURE PIPE USING FLEXIBLE
ELASTOMERIC SEALS
2.B.11. ASTM D3261 - BUTT HEAT FUSSION POLYETHYLENE (PE) PLASTIC FITTINGS
FOR POLYETHYLENE PLASTIC PIPE AND TUBING
2.B.12. ASTM F477 - ELASTOMERIC SEALS (GASKETS) FOR JOINING PLASTIC PIPE
2.B.13. ASTM F1417 - STANDARD TEST METHOD FOR INSTALLATION
ACCEPTANCE OF PLASTIC GRAVITY SEWER LINES USING LOW-PRESSURE
AIR.
2.C. AMERICAN WATER WORKS ASSOCIATION (AWWA):
2.C.1. AWWA C111 - RUBBER_GASKET JOINTS FOR DUCTILE IRON PRESSURE PIPE
AND FITTINGS
2.C.2. AWWA C600 - DUCTILE-IRON WATER MAINS AND THEIR APPURTENANCES
2.C.3. AWWA C900 - POLYVINYL CHLORIDE (PVC) PRESSURE PIPE, 4 IN. THROUGH
12 IN, FOR WATER DISTRIBUTION
2.C.4. AWWA C901 - POLYETHYLENE (PE) PRESSURE PIPE, TUBING AND
FITTINGS 1/2 INCH THROUGH 3 INCHES, FOR WATER DISTRIBUTION
2.C.5. AWWA C906 - POLYETHYLENE (PE) PRESSURE PIPE AND FITTINGS, 4 INCH
THROUGH 63 INCH, FOR WATER DISTRIBUTION
3. SUBMITTALS
3.A. PROJECT RECORD DOCUMENTS:
3.A.1. ACCURATELY RECORD ACTUAL LOCATIONS OF PIPE RUNS, CONNECTIONS,
CLEANOUTS, AND INVERT ELEVATIONS.
3.A.2. IDENTIFY AND DESCRIBE UNEXPECTED VARIATIONS TO SUBSOIL
CONDITIONS AND LOCATION OF UNCHARTED UTILITIES.
4. PROJECT CONDITIONS
4.A. COORDINATE WORK WITH TERMINATION OF SANITARY SEWER CONNECTION
OUTSIDE BUILDING AND CONNECTION TO MUNICIPAL SEWER UTILITY SERVICE.
PART 2 - PRODUCTS
1. SEWER PIPE, FITTINGS, AND JOINTS
1.A. POLYVINYL CHLORIDE PIPE (PVC): ASTM D 3034, RATED SDR 35 UNLESS
OTHERWISE SPECIFIED BY THE UTILITY COMPANY. PIPE SHALL BE CONTINUALLY
MARKED WITH MANUFACTURER'S NAME, PIPE SIZE, CELL CLASSIFICATION, SDR
RATING, AND ASTM D 3034 CLASSIFICATION.
1.A.1. PIPE JOINTS: INTEGRALLY MOLDED BELL ENDS, ASTM D 3034, TABLE 2, WITH
FACTORY SUPPLIED ELASTOMERIC GASKETS AND LUBRICANT.
1.B. VITRIFIED CLAY PIPE (VCP): ASTM C700: USE ONLY IF REQUIRED BY LOCAL
JURISDICTION.
1.B.1. FITTINGS: ASTM C700
1.B.2. JOINTS: ASTM C425
1.B.3. GASKETS: ASTM C425. GASKETS SHALL BE MANUFACTURED FROM HIGH
GRADE, PROPERLY VULCANIZED ELASTOMERIC COMPOUND CONSISTING OF
EITHER BASIC NATURAL OR SYNTHETIC RUBBER. GASKET MANUFACTURING
TOLERANCES SHALL COMPLY WITH RUBBER MANUFACTURER'S
ASSOCIATION TOLERANCES FOR GASKETS.
1.B.4. LUBRICANT: SUITABLE FOR LUBRICATING JOINT COMPONENTS; NO
DETERIORATING EFFECTS ON GASKET OR PIPE MATERIAL, WILL NOT
SUPPORT GROWTH OF FUNGI OR BACTERIA, AND SHALL BE OF TYPE
RECOMMENDED BY GASKET MANUFACTURER.
1.C. FORCE MAIN:
1.C.1. HIGH-DENSITY POLYETHYLENE PIPE (HDPE): AWWA C901 AND C906, ASTM
D3035, SDR 11 FOR 150 PSI PRESSURE RATING.
1.C.1.1. FITTINGS: MOLDED, AWWA C901 OR C906.
1.C.1.2. JOINTS: BUTT FUSION, ASTM D2657, FLANGED GASKET JOINTS AT
INTERFACE
1.C.2. POLYVINYL CHLORIDE PIPE (PVC): FOR LESS THAN 4 INCHES IN DIAMETER,
ASTM D2241 FOR PUSH-ON OR SOLVENT WELD JOINTS, AND FOR PIPE 4
INCHES IN DIAMETER AND LARGER, AWWA C900, CLASS 150 WITH PUSH-ON
JOINTS.
1.C.2.1. JOINTS/FITTINGS: PUSH-ON, ASTM D3139 WITH ASTM F477 GASKETS.
1.C.2.2. SOLVENT CEMENT: ASTM D2564.
1.C.3. DUCTILE IRON PIPE (DIP): ASTM A746, CLASS 50, INSIDE NOMINAL DIAMETER
AS SHOWN ON THE DRAWINGS, BELL AND SPIGOT END.
1.C.4. DUCTILE IRON PIPE JOINT DEVICE: AWWA C111, RUBBER GASKET JOINT
DEVICES.
2. PIPE ACCESSORIES
2.A. PIPE JOINTS: MECHANICAL CLAMP RING TYPE, STAINLESS STEEL EXPANDING
AND CONTRACTING SLEEVE, NEOPRENE-RIBBED GASKET FOR POSITIVE SEAL.
2.B. FITTINGS: SAME MATERIAL AS PIPE MOLDED OR FORMED TO SUIT PIPE SIZE AND
END DESIGN, IN REQUIRED TEE, BENDS, ELBOWS, CLEANOUTS, REDUCERS,
TRAPS, ETC.
3. CLEANOUTS AND MANHOLES
3.A. MANHOLES SHALL CONFORM TO SECTION 02536.
3.B. LID AND FRAME: PROVIDE IN ACCORDANCE WITH SECTION 02536. PROVIDE
TRAFFIC GRADE AND RATED COVERS AND FRAMES WHERE CLEANOUTS AND
MANHOLES ARE WITHIN PAVEMENT, WITH THE LETTERS “SSCO” OR “SANITARY
SEWER” RESPECTIVELY CAST INTO THE COVER.
3.C. SHAFT CONSTRUCTION: CAST IRON SHAFT OF INTERNAL DIAMETER AS
SPECIFIED ON CONSTRUCTION DRAWINGS WITH 2500 PSI CONCRETE COLLAR
FOR CLEANOUTS.
4. APPURTENANCES
4.A. TRACE WIRE: MAGNETIC DETECTABLE CONDUCTOR (#12 COPPER), BRIGHTLY
COLORED PLASTIC COVERING, IMPRINTED WITH “SANITARY SEWER SERVICE” IN
LARGE LETTERS.
PART 3 - EXECUTION
1. EXAMINATION
1.A. VERIFY THAT TRENCH CUT AND EXCAVATION IS READY TO RECEIVE WORK AND
EXCAVATIONS, DIMENSIONS, AND ELEVATIONS ARE AS INDICATED ON
CONSTRUCTION DRAWINGS.
2. PREPARATION
2.A. HAND TRIM EXCAVATIONS TO REQUIRED ELEVATIONS. CORRECT OVER
EXCAVATION WITH BEDDING MATERIAL.
2.B. REMOVE LARGE STONES OR OTHER HARD MATTER THAT COULD DAMAGE PIPE
OR IMPEDE CONSISTENT BACKFILLING OR COMPACTION.
3. BEDDING
3.A. EXCAVATE TRENCH AND PLACE BEDDING MATERIAL IN ACCORDANCE WITH THE
EARTHWORK SPECIFICATIONS..
4. INSTALLATION - PIPE
4.A. INSTALL TYPE AND CLASS OF PIPE AS SHOWN ON THE DRAWINGS. PIPES SHALL
BE LAID AND MAINTAINED TO THE REQUIRED LINE AND GRADE WITH NECESSARY
FITTINGS, BENDS, MANHOLE RISERS, CLEANOUTS AND OTHER APPURTENANCES
PLACED AT THE REQUIRED LOCATIONS. THE PIPE SHALL BE INSTALLED WITH
UNIFORM BEARING UNDER THE FULL LENGTH OF THE BARREL OF THE PIPE. THE
PIPE SHALL BE INSPECTED FOR DEFECTS AND CRACKS BEFORE BEING
LOWERED INTO THE TRENCH. DEFECTIVE, DAMAGED OR UNSOUND PIPE, OR
PIPE THAT HAS HAD ITS GRADE DISTURBED AFTER LAYING SHALL BE TAKEN UP
AND REPLACED. COMMENCE INSTALLATION AT LOWEST POINT WITH THE BELL
END UPGRADE.
4.B. NO PIPE SHALL BE LAID IN WATER OR WHEN TRENCH CONDITIONS ARE
UNSUITABLE FOR WORK.
4.C. PIPE CONNECTING TO MANHOLES OR OTHER STRUCTURES SHALL TERMINATE
FLUSH INSIDE OF THE STRUCTURE WALL.
4.D. JOINTS FOR PVC AND CISP SHALL BE THOROUGHLY LUBRICATED WITH AN
APPROVED LUBRICANT BEFORE PIPE SECTIONS ARE SLIPPED TOGETHER. OPEN
ENDS SHALL BE FULLY PROTECTED WITH A STOPPER TO PREVENT EARTH OR
OTHER MATERIAL FROM ENTERING THE PIPE DURING CONSTRUCTION.
CAREFULLY FREE INTERIOR OF THE PIPE FROM DIRT, CEMENT AND OTHER
DELETERIOUS MATERIAL AS THE WORK PROGRESSES.
4.E. MAINTAIN SEPARATION OF POTABLE WATER MAIN FROM SEWER PIPING AT
CROSSINGS A MINIMUM OF 10 FEET HORIZONTAL AND 18 INCHES VERTICAL.
4.F. INSTALL HDPE PIPING AND FITTINGS TO AWWA C901 AND C906. BUTT FUSION
WELDED PER ASTM D3261.
4.G. ROUTE PIPE IN STRAIGHT LINE PARALLEL TO ROADS, BUILDINGS AND ADJACENT
UTILITIES AND AS SHOWN ON THE DRAWINGS.
4.H. ESTABLISH ELEVATIONS OF BURIED PIPING WITH SUFFICIENT COVER AS
RECOMMENDED BY PIPE MANUFACTURER TO ENSURE NOT LESS THAN 3 FEET
OF COVER, EXCEPT AS NOTED ON DRAWINGS.
4.I. FORM AND PLACE CONCRETE FOR THRUST BLOCKS AT EACH ELBOW OF PIPE
FORCE MAIN. SEE CONSTRUCTION DRAWING FOR DETAILS OF CONSTRUCTION.
4.J. BACKFILL TRENCH IN ACCORDANCE WITH SECTION 02300.
4.K. INSTALL TRACE WIRE CONTINUOUS OVER TOP OF NON-METAL PIPE. BURY 6
INCHES MINIMUM BELOW FINISH GRADE, ABOVE PIPELINE.
5. INSTALLATION - CLEANOUTS AND MANHOLES
5.A. FORM BOTTOM OF EXCAVATION CLEAN AND SMOOTH TO CORRECT ELEVATION.
5.B. FOR CLEANOUTS, FORM AND PLACE CAST_IN_PLACE CONCRETE BASE PAD WITH
PROVISION FOR SANITARY SEWER PIPE TO BE INSTALLED TO PROPER
ELEVATIONS.
5.C. FOR MANHOLES, CONSTRUCT INVERTS ACCORDING TO THE FOLLOWING
GUIDELINES:
5.C.1. INVERT CHANNEL SHALL BE SMOOTH AND ACCURATELY SHAPED TO A
SEMICIRCULAR BOTTOM TO MATCH WITH THE INSIDE OF THE ADJACENT
SEWER SECTION.
5.C.2. INVERT CHANNELS AND STRUCTURE BOTTOMS SHALL BE SHAPED WITH
MORTAR AND LEAN CONCRETE.
5.C.3. CHANGES IN SIZE AND GRADE OF INVERT SHALL BE MADE GRADUALLY AND
EVENLY.
5.C.4. CHANGES IN THE DIRECTION OF THE SEWER ENTERING BRANCH OR
BRANCHES SHALL HAVE A TRUE CURVE OF AS LARGE A RADIUS AS THE
MANHOLE WILL PERMIT.
5.D. FOR MANHOLES, PROVIDE MANHOLE RINGS, FRAME, AND COVER AS SHOWN ON
THE CONSTRUCTION DRAWINGS.
6. FIELD QUALITY CONTROL
6.A. FIELD QUALITY CONTROL SHALL BE CONDUCTED BY THE CONTRACTOR IN
ACCORDANCE WITH SECTION 01452.
6.B. PIPES AND JOINTS SHALL NOT BE COMPLETELY BACKFILLED UNTIL AFTER
INSPECTION, TESTING, AND APPROVAL BY THE OWNER AND LOCAL
JURISDICTION.
6.C. PRIOR TO TESTING FOR LEAKAGE, THE PIPE TRENCH SHALL BE BACKFILLED TO
AT LEAST THE SPRING LINE OF THE PIPE. IF REQUIRED TO PREVENT PIPE
MOVEMENT DURING TESTING, ADDITIONAL BACKFILL SHALL BE ADDED LEAVING
THE PIPE JOINTS UNCOVERED TO PERMIT INSPECTION.
6.D. EXFILTRATION TEST
6.D.1. EACH SECTION OF SEWER LINE BETWEEN SUCCESSIVE MANHOLES SHALL
BE TESTED BY CLOSING THE LOWER END OF THE SEWER TO BE TESTED AND
THE INLET SEWER OF THE UPPER MANHOLE, USING STOPPERS.
6.D.2. FILL THE MANHOLE AND PIPE WITH WATER TO A POINT WHICH PRODUCES A
MAXIMUM OF 3 FEET OF HEAD ABOVE THE INVERT OF THE SEWER AT THE
CENTER OF THE UPPER MANHOLE; OR IF GROUNDWATER IS PRESENT, 3
FEET OF HEAD ABOVE THE AVERAGE ADJACENT GROUNDWATER LEVEL.
6.D.3. THE ALLOWABLE LEAKAGE SHALL BE 200 GAL/INCH OF PIPE
DIAMETER/MILE/DAY
6.E. INFILTRATION TEST
6.E.1. IF EXCESSIVE GROUND WATER IS ENCOUNTERED IN THE CONSTRUCTION OF
A SECTION OF THE SEWER, THE EXFILTRATION TEST SHALL NOT BE USED.
6.E.2. THE UPPER AND LOWER ENDS OF THE SEWER TO BE TESTED SHALL BE
CLOSED SUFFICIENTLY TO PREVENT THE ENTRANCE OF WATER.
6.E.3. PUMPING OF GROUND WATER SHALL BE DISCONTINUED FOR AT LEAST 3
DAYS; THEN INFILTRATION SHALL BE TESTED.
6.E.4. INFILTRATION INTO EACH SECTION OF SEWER BETWEEN ADJOINING
MANHOLES SHALL NOT EXCEED THAT ALLOWED FOR THE EXFILTRATION
TEST, EXCEPT THAT HEAD CONDITIONS SHALL BE A MAXIMUM OF 6 FEET.
6.F. THE EXFILTRATION TEST MAY BE LIMITED TO THE MANHOLES ONLY WHEN THE
AUTHORITY HAVING JURISDICTION DOES NOT REQUIRE THE TEST AND THE
CONSTRUCTION MANAGER WAIVES THE TEST. THE INFILTRATION TEST WILL
ALWAYS BE REQUIRED WHEN EXCESSIVE GROUND WATER IS ENCOUNTERED IN
ADDITION TO THE AIR TEST.
6.G. AIR TEST: GRAVITY SYSTEMS SHALL BE AIR TESTED BETWEEN MANHOLES AT 3.5
PSI FOR 5 MINUTES PER ASTM F1417 FOR PLASTIC PIPES.
6.H. ALL MANHOLES SHALL BE AIR TESTED IN ACCORDANCE WITH ASTM C1244-93
(STANDARD TEST METHOD FOR CONCRETE SEWER MANHOLES BY NEGATIVE AIR
PRESSURE (VACUUM) TEST).
6.I. DEFLECTION TEST:
6.I.1. DEFLECTION TESTS SHALL BE CONDUCTED ON ALL PLASTIC PIPE USING A
MANDREL WITH A DIAMETER EQUAL TO 95 PERCENT OF THE INSIDE
DIAMETER OF THE PIPE. THE TEST SHALL BE PERFORMED WITHOUT
MECHANICAL PULLING DEVICES.
6.I.2. ALLOWABLE DEFLECTION: MAXIMUM ALLOWABLE PIPE DEFLECTION SHALL
NOT EXCEED 5 PERCENT OF NOMINAL INSIDE DIAMETER.
6.I.3. MANDREL: MANDREL, GO/NO-GO, DEVICE SHALL BE CYLINDRICAL IN SHAPE
AND CONSTRUCTED WITH EITHER 9 OR 16 EVENLY SPACED ARMS OR
PRONGS. MANDRELS WITH FEWER ARMS WILL BE REJECTED AS NOT
SUFFICIENTLY ACCURATE. CONTACT LENGTH OF MANDREL'S ARMS SHALL
EQUAL OR EXCEED NOMINAL INSIDE DIAMETER OF SEWER TO BE
INSPECTED. CRITICAL MANDREL DIMENSIONS SHALL CARRY TOLERANCE OF
0.01-INCH MAXIMUM. CONTRACTOR SHALL PROVIDE MANDREL AND
NECESSARY EQUIPMENT FOR MANDREL TEST.
6.I.4. PROCEDURE: MANDREL SHALL BE HAND-PULLED THROUGH FLEXIBLE PIPE
SEWER LINES NO EARLIER THAN 30 DAYS AFTER TRENCH HAS BEEN
COMPLETELY BACKFILLED. SECTIONS OF SEWER NOT PASSING MANDREL
SHALL BE UNCOVERED AND REBEDDED, REROUNDED, OR REPLACED TO
SATISFACTION OF OWNER OR GOVERNING AGENCY. REPAIRED SECTION
SHALL BE RETESTED.
6.J. HYDROSTATIC TEST: FORCE MAIN PIPING SHALL BE HYDROSTATICALLY TESTED
AT 150 PSI IN ACCORDANCE WITH AWWA C 600.
6.K. PROVIDE MEASURING DEVICES, METERS, WATER, MATERIALS, AND LABOR FOR
MAKING THE REQUIRED TESTS.
6.L. TESTS SHALL BE CONDUCTED IN THE PRESENCE OF THE CONSTRUCTION
MANAGER OR HIS DESIGNEE. TEST DATA SHALL BE SUBMITTED TO THE
ENGINEER FOR REVIEW AND APPROVAL.
END OF SECTION REVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, Indiana W19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
EXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJSENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
07/14/21
DECIDUOUS SHRUBS
EVERGREEN SHRUBS
PLANT SCHEDULE
PLAN
KEY BOTANICAL NAME COMMON NAME SIZE QUANTIT Y R OOT CONDITION
B & B B ARE C ONT
ON CENTER
SPACING
SPECIA L
IN STRUCTI O NS
PfG
SxG SPIRAEA X 'GOLD MOUND'
POTENTILLA FRUTICOSA 'GOLDFINGER' GOLDFINGER POTENTILLA
GOLD MOUND SPIREA
#2
#3
X
X SEE PLAN
SEE PLAN MIN 18"
MIN 18"
BkG
IgC ILEX GLABRA 'CHAMZIN'
BUXUS X KOREANA 'GREEN GEM' GREEN GEM BOXWOOD
NORDIC HOLLY 18"
18"
X
X SEE PLAN
SEE PLAN MIN 18"
MIN 18"
10
9
11
16
MATURE SIZE
3'T x 3'W
30"T x 36"W
2'T x 2'W
4'T x 4'W
TREES
TD TAXODIUM DISTICHUM BALD CYPRESS X SEE PLAN MIN 6'6 35'T x 20'W
BN BETULA NIGRA RIVER BIRCH X SEE PLAN MIN 6'6 35'T x 20'W
E
OHU OHU OHUOHU OHU OHU
OHU OHU
OHU
O HU
OHU
OHU
OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU
G
W
W
W
G
G
W
WEST C
A
R
M
E
L
D
R
I
V
E
C C C
CGGG
PROPOSED BUILDING
20,121SF± PER FLOOR
F.F.E. = 829.85CSTM STM STM STM STM STMSTM STM STM STM STM STM STMESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS W W W W W W W W W W W W W WW W W WEE E E E E E E E EDRY POND
LANDSCAPE PLAN NOTES
SEED / SOD (ALTERNATE) - FOR SEED, REFER TO PERMANENT SEEDING CHART
ON SHEET L201 LANDSCAPE DETAIL SHEET. SOD SHALL BE CERTIFIED GRADE
CULTIVATED GRASS SOD: OF "ADVENTURE BLEND" TURF TYPE TALL FESCUE (BY
GENERAL CONTRACTOR). REFER TO THE SWPPP SHEETS FOR GRASS PLANTING
LOCATIONS.
LANDSCAPE BED EDGE (TYP.)
MULCH
NATIVE PLANTINGS FOR THE BASIN BOTTOM. REFER TO THE SWPPP SHEETS
FOR PLANTING SCHEDULE.W190582-L100GENERAL NOTES
1. IN CASE OF DISCREPANCIES BETWEEN THE PLAN AND THE PLANT LIST, THE PLAN SHALL DICTATE. IF IN QUESTION, CONTACT THE
LANDSCAPE DESIGNER.
2. ANY EXISTING TREE(S) THAT MAY REQUIRE REMOVAL BUT ARE NOT SHOWN ON THE PLAN AS BEING REMOVED SHALL BE BROUGHT TO THE
ATTENTION OF THE LANDSCAPE ARCHITECT. TREE(S) MAY BE RELOCATED (OR REPLACED) TO AN APPROVED ALTERNATE LOCATION
ONSITE FOLLOWING LANDSCAPE ARCHITECT APPROVAL.
3. ALL SHRUBS PLANTING AREAS TO BE COVERED WITH 3" THICK LAYER OF SHREDDED HARDWOOD BARK MULCH. ALL GROUND COVER BEDS
SHALL BE COVERED WITH 1" SHREDDED HARDWOOD BARK MULCH. BARK MULCH SHALL BE APPROVED BY LANDSCAPE DESIGNER AND
SHALL BE UNIFORM IN TEXTURE AND COLOR AND SHALL BE OBTAINED FROM SAWMILL OR LUMBERING OPERATIONS. NO UTILITY MULCH
OR PROCESSED TREE TRIMMINGS WILL BE ALLOWED.
4. AN APPROVED PRE-EMERGENT HERBICIDE SHALL BE APPLIED IN ALL PLANTING AND GROUND COVER BEDS AT RATES SPECIFIED BY
MANUFACTURER FOR EACH VARIETY OF PLANT.
5. FINAL PLACEMENT OF PLANT MATERIALS, ETC. SHALL BE APPROVED BY LANDSCAPE DESIGNER BEFORE PLANTING OPERATIONS ARE TO
PROCEED. ALL TREE LOCATIONS SHALL BE MARKED WITH A WOODED STAKE INDICATING VARIETY AND SIZE OF TREE. ALL GROUND
COVER AND MULCH BED LINES SHALL BE MARKED BY A HIGHLY VISIBLE PAINT LINE WITH OCCASIONAL WOOD STAKES FOR REFERENCE.
ALL STAKES SHALL BE REMOVED FOLLOWING PLANTINGS OPERATIONS. LANDSCAPE DESIGNER RESERVES THE RIGHT TO ADJUST PLANT
LOCATIONS ON SITE.
6. NO SUBSTITUTIONS OF PLANT MATERIAL WILL BE ALLOWED. IF PLANTS ARE SHOWN TO BE UNAVAILABLE, THE CONTRACTOR SHALL
NOTIFY LANDSCAPE DESIGNER PRIOR TO BID DATE IN WRITING. ALL PLANTS SHALL BE INSPECTED AND TAGGED WITH PROJECT
IDENTIFICATION AT NURSERY OR CONTRACTORS OPERATION PRIOR TO MOVING TO JOB SITE. PLANTS MAY ALSO BE INSPECTED AND
APPROVED OR REJECTED ON THE JOB SITE.
7. ALL PLANTS ARE TO MEET OR EXCEED AMERICAN STANDARDS FOR NURSERY STOCK, LATEST EDITION, AS SET FORTH BY AMERICAN
ASSOCIATION OF NURSERYMEN.
8. PLANTS AND ALL OTHER MATERIALS TO BE STORED ON SITE WILL BE PLACED WHERE THEY WILL NOT CONFLICT WITH CONSTRUCTION
OPERATIONS AND AS DIRECTED BY OWNER.
9. ALL NEW LANDSCAPE PLANTINGS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FOLLOWING FINAL INSPECTION BY LANDSCAPE
DESIGNER. AT THE END OF THIS PERIOD, PLANT MATERIAL TERMED DEAD OR UNSATISFACTORY BY LANDSCAPE DESIGNER SHALL BE
REPLACED AT NO ADDITIONAL CHARGE BY THE LANDSCAPE CONTRACTOR.
10. THE LANDSCAPE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND FEES THAT MAY BE REQUIRED FOR HIS PORTION OF WORK.
11. PEAT MOSS TO BE USED ON PROJECT SHALL BE A DOMESTIC OR IMPORTED MATERIAL, CHOCOLATE BROWN IN COLOR AND COMPOSED OF
PARTIALLY DECOMPOSED VEGETABLE MATERIAL. PEAT MOSS TO ALSO BE MILDLY ACIDIC IN CHARACTER AND SHALL MEET APPROVAL OF
LANDSCAPE DESIGNER.
12. LANDSCAPE CONTRACTOR SHALL NOTIFY LANDSCAPE DESIGNER IN WRITING PRIOR TO BID DATE OF ANY PLANTS THAT HE FEELS MAY NOT
SURVIVE IN LOCATIONS NOTED.
13. ALL LANDSCAPING PLANTINGS TO BE MAINTAINED FOR 1 YEAR FOLLOWING TURNOVER. MAINTENANCE TO INCLUDE WATERING, WEEDING,
CULTIVATION, MULCHING, MOWING AND ALL OTHER NECESSARY OPERATIONS REQUIRED FOR PROPER ESTABLISHMENT OF PLANTINGS.
NOTE: AT END OF MAINTENANCE PERIOD, CONTRACTOR TO REMOVE GUYING AND STAKING FROM TREES.
14. CONTRACTOR TO SUBMIT UNIT PRICES ON EVERY TYPE OF WORK AS REQUESTED BY LANDSCAPE DESIGNER.
15. BACKFILL FOR TREE AND SHRUB PLANTING SHALL BE 75% APPROVED TOPSOIL AND 25% APPROVED PEAT MOSS. TOP LAYER OF BACKFILL
SHALL BE 100% EXISTING TOPSOIL. A 5-10-5 ANALYSIS SLOW RELEASE FERTILIZER SHALL BE INCORPORATED INTO BACKFILL AT
APPROVED RATES.
16. PROVIDE MINIMUM 4" PLANTING SOIL IN ALL GROUND COVER AND FLOWER AREAS WITH MIXTURE COMPRISING OF ONE PART COMMERCIAL
GRADE 'POTTING SOIL,' 5 PARTS TOPSOIL AND 4 PARTS PEAT MOSS. A FULL 4" LAYER OF APPROVED SHREDDED FIBROUS PEAT MOSS MAY
BE USED IN LIEU OF PLANTING MIX.
17. PLANTS SHALL BEAR A TAG SHOWING GENUS, SPECIES AND VARIETY. REMOVE AT TIME OF FINAL ACCEPTANCE.
18. PLANTS SHALL BE CERTIFIED BY THE STATE OF INDIANA DEPARTMENT OF NATURAL RESOURCES AND FREE FROM DISEASE OR
HAZARDOUS INSECTS.
19. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL EXISTING UTILITIES PERTAINING TO THEIR PHASE OF WORK.
UTILITIES ARE SHOWN TO BE APPROXIMATE. CALL UTILITY LOCATE PRIOR TO ANY PLACEMENT OF PLANT MATERIAL OR OTHER LANDSCAPE
MATERIAL.
20. CONTRACTOR TO REVIEW THE SWPPP SERIES PLANS FOR STABILIZATION (SEEDING/SOD/MULCH) REQUIREMENTS.
L100LANDSCAPE PLANREQUIREMENT: PROVIDED:
LANDSCAPE ORDINANCE REQUIREMENTS
RANGE LINE ROAD OVERLAY - SECTION 3.79 RL-OL PARKING STANDARDS
- D. PARKING AREAS SHALL BE LOCATED AT THE REAR OR SIDE OF BUILDINGS, AND SCREENED
CONSISTENT WITH THE STANDARDS OF BUFFERYARD TYPE "A" AS DESCRIBED IN ARTICLE 5, SECTION
5.21: BUFFERYARD STANDARDS
BUFFERYARD TYPE "A" =
- MIN. FRONT AND SIDE YARD = 5'
- MIN. REAR YARD = 10'
- MIN. SHADE OR EVERGREEN TREES PER 100' = 4
RANGE LINE ROAD OVERLAY - SECTION 3.75 RL-OL LANDSCAPING STANDARDS
- A. PROTECTION OF EXISTING TREES AND VEGETATION
- 1. SITES WITHIN THE RL-OL DISTRICT WITH EXISTING TREES OR STANDS
SHALL PROTECT AND INCORPORATE THEM INTO THE OVERALL SITE
DESIGN. THE LANDSCAPE PLAN SHALL PRESERVE NOT LESS THAN 50% OF
ALL TREES THAT ARE:
A. 6" DBH OR LARGER AND
B. LOCATED WITHIN THE BUFFERYARD OR GREENBELT
NA
REQUIRED:
NA
PER PLAN AS
SPACE
ALLOWS.
NA
REVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, Indiana W19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
CARMEL SELF STORAGEISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJS
W
S
N
E E N GI N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil Engi neeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SM08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
BUFFERYARD TYPE "D" =
- 8 SHADE TREES, 2 ORNAMENTAL TREES, AND 20 SHRUBS PER 100'. 10 SHADE
2 ORNAMENTAL
26 SHRUBS
10 SHADE
2 ORNAMENTAL
26 SHRUBS
07/14/21
W190582-L100L200LANDSCAPE PLAN DETAILSNOTES
1. AN OAT OR WHEAT COMPANION OR NURSE CROP MAY BE USED WITH ANY OF THE ABOVE
PERMANENT SEEDING MIXTURES, AT THE FOLLOWING RATES:
1.A. SPRING OATS - ONE-FOURTH TO THREE-FOURTHS BUSHEL PER ACRE
1.B. WHEAT - NO MORE THAN ONE-HALF BUSHEL PER ACRE
2. A HIGH POTENTIAL FOR FERTILIZER, SEED, AND MULCH TO WASH EXISTS ON STEEP BANKS,
CUTS, AND IN CHANNELS AND AREAS OF CONCENTRATED
INSTALLATION
1. GRADE THE SITE TO ACHIEVE POSITIVE DRAINAGE.
2. ADD TOPSOIL OR COMPOST MULCH TO ACHIEVE NEEDED DEPTH FOR ESTABLISHMENT OF
VEGETATION. (COMPOST MATERIAL MAY BE ADDED TO IMPROVE SOIL MOISTURE HOLDING
CAPACITY, SOIL FRIABILITY, AND NUTRIENT AVAILABILITY.)
SEEDBED PREPARATION
1. TEST SOIL TO DETERMINE PH AND NUTRIENT LEVELS.
2. APPLY SOIL AMENDMENTS AS RECOMMENDED BY THE SOIL TEST AND WORK INTO THE
UPPER TWO TO FOUR INCHES OF SOIL. IF TESTING IS NOT DONE, APPLY 400 TO 600
POUNDS PER ACRE OF 12-12-12 ANALYSIS FERTILIZER, OR EQUIVALENT.
3. TILL THE SOIL TO OBTAIN A UNIFORM SEEDBED. USE A DISK OR RAKE, OPERATED ACROSS
THE SLOPE, TO WORK THE SOIL AMENDMENTS INTO THE UPPER TWO TO FOUR INCHES OF
THE SOIL.
SEEDING
OPTIMUM SEEDING DATES ARE MARCH 1 TO MAY 10 AND AUGUST 10 TO SEPTEMBER 30.
PERMANENT SEEDING DONE BETWEEN MAY 10 AND AUGUST 10 MAY NEED TO BE IRRIGATED.
SEEDING OUTSIDE OR BEYOND OPTIMUM SEEDING DATES IS STILL POSSIBLE WITH THE
UNDERSTANDING THAT RESEEDING OR OVERSEEDING MAY BE REQUIRED IF ADEQUATE
SURFACE COVER IS NOT ACHIEVED. RESEEDING OR OVERSEEDING CAN BE EASILY
ACCOMPLISHED IF THE SOIL SURFACE REMAINS WELL PROTECTED WITH MULCH.
1. SELECT A SEEDING MIXTURE AND RATE FROM TABLE 1. SELECT SEED MIXTURE BASED ON
SITE CONDITIONS, SOIL PH, INTENDED LAND USE, AND EXPECTED LEVEL OF MAINTENANCE.
2. APPLY SEED UNIFORMLY WITH A DRILL OR CULTIPACKER SEEDER OR BY BROADCASTING.
PLANT OR COVER THE SEED TO A DEPTH OF ONE-FOURTH TO ONE-HALF INCH. IF DRILLING
OR BROADCASTING THE SEED, ENSURE GOOD SEED-TO-SOIL CONTACT BY FIRMING THE
SEEDBED WITH A ROLLER OR CULTIPACKER AFTER COMPLETING SEEDING OPERATIONS.
(IF SEEDING IS DONE WITH A HYDROSEEDER, FERTILIZER AND MULCH CAN BE APPLIED
WITH THE SEED IN A SLURRY MIXTURE.)
3. MULCH ALL SEEDED AREAS AND USE APPROPRIATE METHODS TO ANCHOR THE MULCH IN
PLACE. CONSIDER USING EROSION CONTROL BLANKETS ON SLOPING AREAS AND
CONVEYANCE CHANNELS
MAINTENANCE
1. INSPECT WITHIN 24 HOURS OF EACH RAIN EVENT AND AT LEAST ONCE EVERY SEVEN
CALENDAR DAYS UNTIL THE VEGETATION IS SUCCESSFULLY ESTABLISHED.
2. CHARACTERISTICS OF A SUCCESSFUL STAND INCLUDE VIGOROUS DARK GREEN OR
BLUISHGREEN SEEDLINGS WITH A UNIFORM VEGETATIVE COVER DENSITY OF 90 PERCENT
OR MORE.
3. CHECK FOR EROSION OR MOVEMENT OF MULCH.
4. REPAIR DAMAGED, BARE, GULLIED, OR SPARSELY VEGETATED AREAS AND THEN
FERTILIZE, RESEED, AND APPLY AND ANCHOR MULCH.
5. IF PLANT COVER IS SPARSE OR PATCHY, EVALUATE THE PLANT MATERIALS CHOSEN, SOIL
FERTILITY, MOISTURE CONDITION, AND MULCH APPLICATION; REPAIR AFFECTED AREAS
EITHER BY OVERSEEDING OR PREPARING A NEW SEEDBED AND RESEEDING. APPLY AND
ANCHOR MULCH ON THE NEWLY SEEDED AREAS.
6. IF VEGETATION FAILS TO GROW, CONSIDER SOIL TESTING TO DETERMINE SOIL PH OR
NUTRIENT DEFICIENCY PROBLEMS. (CONTACT YOUR SOIL AND WATER CONSERVATION
DISTRICT OR COOPERATIVE EXTENSION OFFICE FOR ASSISTANCE.)
7. IF ADDITIONAL FERTILIZATION IS NEEDED TO GET A SATISFACTORY STAND, DO SO
ACCORDING TO SOIL TEST RECOMMENDATIONS.
8. ADD FERTILIZER THE FOLLOWING GROWING SEASON. FERTILIZE ACCORDING TO SOIL TEST
RECOMMENDATIONS.
9. FERTILIZE TURF AREAS ANNUALLY. APPLY FERTILIZER IN A SPLIT APPLICATION. FOR
COOL-SEASON GRASSES, APPLY ONE-HALF OF THE FERTILIZER IN LATE SPRING AND
ONE HALF IN EARLY FALL. FOR WARM-SEASON GRASSES, APPLY ONE-THIRD IN EARLY
SPRING, ONE-THIRD IN LATE SPRING, AND THE REMAINING ONE-THIRD IN MIDDLE SUMMER.
TABLE 1. PERMANENT SEEDING RECOMMENDATIONS
THIS TABLE PROVIDES SEVERAL SEED MIXTURE OPTIONS. ADDITIONAL SEED MIXTURES ARE
AVAILABLE COMMERCIALLY. WHEN SELECTING A MIXTURE, CONSIDER INTENDED LAND USE
AND SITE CONDITIONS, INCLUDING SOIL PROPERTIES (E.G., SOIL PH AND DRAINAGE), SLOPE
ASPECT, AND THE TOLERANCE OF EACH SPECIES TO SHADE AND DROUGHT.
REFERENCE IN CHAPTER 7 PAGES 35-40 IN THE INDIANA STORM WATER QUALITY MANUAL
LAWNS AND HIGH-MAINTENANCE AREAS
1. BLUEGRASS
2. PERENNIAL RYEGRASS
(TURF TYPE)
3. TALL FESCUE (TURF TYPE)
- BLUEGRASS
170 LBS.
30 LBS.
CHANNELS AND AREAS OF CONCENTRATED FLOW
1. PERENNIAL RYEGRASS
- WHITE
2. KENTUCKY BLUEGRASS
- SMOOTH BROMEGRASS
- SWITCHGRASS
- TIMOTHY
- PERENNIAL RYEGRASS
- WHITE CLOVER
20 LBS.
10 LBS.
3 LBS.
4 LBS.
10 LBS.
2 LBS.
3. TALL FESCUE
- WHITE CLOVER
150 LBS.
2 LBS.
4. TALL FESCUE
- PERENNIAL RYEGRASS
- KENTUCKY BLUEGRASS 5.5 TO 7.5
140 LBS. 5.5 TO 7.0
60 LBS.
90 LBS.5.6 TO 7.0
5.6 TO 7.5
150 LBS.
2 LBS. 5.5 TO 7.0
5.5 TO 7.5
5.5 TO 7.5
150 LBS.
20 LBS.
20 LBS.
PERMANENT SEED
SEED MIXTURES RATE PER ACRE PURE LIVE SEED OPTIMUM SOIL PH
SEED MIXTURES RATE PER ACRE PURE LIVE SEED OPTIMUM SOIL PH
(NO SCALE)
V-CUT LANDSCAPE BED EDGE DETAIL4-6"2-4"3" LAYER OF
SHREDDED
HARDWOOD MULCH
"V" DEFINES EDGE AND
HOLDS IN MULCH
SPECIFICATIONS
SITE PREPARATION
_ GRADE THE SITE TO ACHIEVE POSITIVE DRAINAGE.
_ PREPARE A SMOOTH, FIRM SOIL SURFACE AND APPLY SOIL AMENDMENTS. IRRIGATION IRRIGATE AS NEEDED TO ENSURE
ROOTING OF SOD.
MATERIALS
_ SOIL AMENDMENTS - SELECT MATERIALS AND RATES AS DETERMINED BY A SOIL TEST (CONTACT YOUR COUNTY SOIL AND
WATER CONSERVATION DISTRICT OR COOPERATIVE EXTENSION OFFICE FOR ASSISTANCE AND SOIL INFORMATION, INCLUDING
AVAILABLE SOIL TESTING SERVICES.) OR 400 TO 600 POUNDS OF 12-12-12 ANALYSIS FERTILIZER, OR EQUIVALENT.
_ SOD - SELECT A HIGH QUALITY, HEALTHY, VIGOROUS VARIETY WELL ADAPTED TO THE REGION AND COMPATIBLE WITH THE
INTENDED USE.
INSTALLATION
SOD SHOULD NOT BE INSTALLED DURING HOT WEATHER, ON DRY SOIL, FROZEN SOIL, COMPACTED CLAY, LOOSE SAND OR
GRAVELLY SUBSTRATE SOILS, AGGREGATE, OR PESTICIDE TREATED SOIL. THE IDEAL TIME TO LAY SOD IS MAY 1 TO JUNE 1 OR
SEPTEMBER 1 TO SEPTEMBER 30, ALTHOUGH IT CAN BE INSTALLED AS EARLY AS MARCH 15 IF AVAILABLE OR JUNE 1 TO
SEPTEMBER 1 IF IRRIGATED.
SITE PREPARATION
1. APPLY TOPSOIL IF EXISTING SOIL CONDITIONS ARE UNSUITABLE FOR ESTABLISHING VEGETATION.
2. GRADE THE SITE TO ACHIEVE POSITIVE DRAINAGE AND CREATE A SMOOTH, FIRM SOIL SURFACE.
3. WHERE APPLICABLE, USE A CHISEL PLOW, DISK, HARROW, OR RAKE TO BREAK UP COMPACTED SOILS AND CREATE A
FAVORABLE ROOTING DEPTH OF SIX TO EIGHT INCHES.
SOD BED PREPARATION
1. TEST SOIL TO DETERMINE PH AND NUTRIENT LEVELS.
2. IF SOIL PH IS TOO ACIDIC FOR THE GRASS SOD TO BE INSTALLED, APPLY LIME ACCORDING TO SOIL TEST RESULTS OR AT THE
RATE RECOMMENDED BY THE SOD SUPPLIER.
3. APPLY FERTILIZER AS RECOMMENDED BY THE SOIL TEST. IF TESTING WAS NOT DONE, APPLY 400 TO 600 POUNDS PER ACRE OF
12-12-12 ANALYSIS FERTILIZER, OR EQUIVALENT.
4. WORK THE SOIL AMENDMENTS INTO THE UPPER TWO TO FOUR INCHES OF SOIL WITH A DISK OR RAKE OPERATED ACROSS THE
SLOPE.
5. RAKE OR HARROW THE AREA TO ACHIEVE A SMOOTH FINAL GRADE AND THEN ROLL OR CULTIPACK THE SOIL SURFACE TO
CREATE A FIRM SURFACE ON WHICH TO LAY THE SOD.
LAYING THE SOD
1. INSTALL SOD WITHIN THIRTY-SIX HOURS OF ITS CUTTING.
2. STORE THE SOD IN A SHADED LOCATION DURING INSTALLATION.
3. IMMEDIATELY BEFORE LAYING THE SOD, RAKE THE SOIL SURFACE TO BREAK ANY CRUST. (IF THE WEATHER IS HOT, LIGHTLY
IRRIGATE THE SOIL SURFACE PRIOR TO LAYING THE SOD.)
4. LAY SOD STRIPS IN A BRICK-LIKE PATTERN.
5. BUTT ALL JOINTS TIGHTLY AGAINST EACH OTHER (DO NOT STRETCH OR OVERLAP THEM), USING A KNIFE OR MASON'S TROWEL
TO TRIM AND FIT SOD INTO IRREGULARLY SHAPED AREAS.
6. ROLL THE SOD LIGHTLY AFTER INSTALLATION TO ENSURE FIRM CONTACT BETWEEN THE SOD AND SOIL.
7. IRRIGATE NEWLY SODDED AREAS UNTIL THE UNDERLYING SOIL IS WET TO A DEPTH OF FOUR INCHES, AND THEN KEEP MOIST
UNTIL THE GRASS TAKES ROOT.
SLOPE APPLICATION
1. INSTALL THE SOD STRIPS WITH THE LONGEST DIMENSION PERPENDICULAR TO THE SLOPE.
2. WHERE SLOPES EXCEED A RATIO OF 3:1, STAPLE OR STAKE EACH STRIP AT THE CORNERS AND IN THE MIDDLE.
CHANNEL APPLICATION
(SODDING PROVIDES QUICKER PROTECTION THAN SEEDING AND MAY REDUCE THE RISK OF EARLY WASHOUT.)
1. EXCAVATE THE CHANNEL, ALLOWING FOR THE FULL THICKNESS OF THE SOD.
2. LAY THE SOD STRIPS WITH THE LONGEST DIMENSION PERPENDICULAR TO CHANNEL FLOW.
3. STAPLE OR STAKE EACH STRIP OF SOD AT THE CORNERS AND IN THE MIDDLE.
4. STAPLE JUTE OR BIODEGRADABLE POLYPROPYLENE NETTING OVER THE SODDED AREA TO MINIMIZE THE POTENTIAL FOR
WASHOUT DURING ESTABLISHMENT.
MAINTENANCE
_ INSPECT WITHIN 24 HOURS OF EACH RAIN EVENT AND AT LEAST ONCE EVERY SEVEN CALENDAR DAYS UNTIL SOD IS WELL
ROOTED.
_ KEEP SOD MOIST UNTIL FULLY ROOTED.
_ AFTER SOD IS WELL-ROOTED (TWO TO THREE WEEKS), MAINTAIN A PLANT HEIGHT OF TWO TO THREE INCHES.
_ TIME MOWING TO AVOID RUTS IN TURF.
_ FERTILIZE TURF AREAS ANNUALLY. APPLY FERTILIZER IN A SPLIT APPLICATION. FOR COOL SEASON GRASSES, APPLY ONE-HALF
OF THE FERTILIZER IN LATE SPRING AND ONE-HALF IN EARLY FALL. FOR WARM-SEASON GRASSES, APPLY ONE-THIRD IN EARLY
SPRING, ONE-THIRD IN LATE SPRING AND ONE-THIRD IN MID-SUMMER.
REFERENCE IN CHAPTER 7 PAGES 47-50 IN THE INDIANA STORM WATER QUALITY MANUAL
CROSS SECTION
PERSPECTIVE VIEW
(NO SCALE)
SOD APPLICATION DETAIL
REVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, IndianaW19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
CARMEL SELF STORAGEISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJSE N G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil Engi neeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SM08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
07/14/21
GENERAL STRUCTURAL NOTES
DESIGN CODES:
2012 INTERNATIONAL BUILDING CODE
ASCE 7-10 MINIMUM DESIGN LOADS AND ASSOCIATED CRITERIA FOR
BUILDINGS AND OTHER STRUCTURES.
DESIGN LOADS:
ROOF DEAD LOAD UNO
GROUND SNOW LOAD (Pg)
Ce = 1.0
Ct = 1.0
I = 1.0
ROOF SNOW LOAD (PLUS SNOW DRIFTING)
INCLUDES 5 PSF RAIN ON SNOW SURCHARGE
FLOOR LIVE LOAD
ULTIMATE DESIGN WIND SPEED
NOMINAL DESIGN WIND SPEED
RISK CATEGORY
EXPOSURE CATEGORY
INTERNAL PRESSURE COEFFICIENT
END ZONE WIDTH (a)
NOTES:
IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DESIGN AND
PROVIDE ADEQUATE TEMPORARY SHORING AND LATERAL BRACING
FOR ALL STRUCTURAL ELEMENTS INCLUDING WALLS, COLUMNS,
BEAMS, LINTELS, ETC. FOR WIND, SOIL AND CONSTRUCTION
LATERAL AND GRAVITY LOADS. THE BRACING MUST REMAIN IN
PLACE UNTIL PERMANENT STRUCTURAL SUPPORTS, INCLUDING
ROOF AND FLOOR DIAPHRAGMS ARE INSTALLED AND HAVE
REACHED THEIR ALLOWABLE SERVICE STRESSES.
IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO ENSURE THAT
CONSTRUCTION CONFORMS TO THE LATEST OSHA SAFETY
REQUIREMENTS. NOTIFY THE ARCHITECT AND ENGINEER
IMMEDIATELY IF ANY REVISIONS ARE REQUIRED TO THE DRAWINGS
DUE TO OSHA SAFETY REQUIREMENTS.
GEOTECHNICAL ENGINEER SHALL FIELD VERIFY SOIL BEARING
CAPACITY. NOTIFY ARCHITECT AND ENGINEER IF ANY
DISCREPANCIES ARE FOUND.
THIS PROJECT IS NOT DESIGNED FOR FUTURE CONSTRUCTION.
ALLOWABLE SOIL BEARING PRESSURE
MODULUS OF SUBGRADE REACTION
15 PSF -----------------------------------
20 PSF -----------------------------------
25 PSF -----------------------------------
125 PSF ---------------------------------
115 MPH ---------------------------------
90 MPH-----------------------------------
II --------------------------------------------
B -------------------------------------------
± 0.18 -------------------------------------
8 FT ---------------------------------------
COMPONENT AND CLADDING ULTIMATE WIND PRESSURES (PSF)
INTERIOR ZONE
END ZONE
25.9
31.2
24.5
28.2
23.3
25.9
20.8
20.8
20 FT² ZONE
EFFECTIVE
AREA
SEISMIC IMPORTANCE FACTOR (I)
RISK CATEGORY
SITE CLASS
SEISMIC DESIGN CATEGORY
MAPPED SPECTRAL RESPONSE
ACCELERATION PARAMETER (SS)
MAPPED SPECTRAL RESPONSE
ACCELERATION PARAMETER (S1)
DESIGN SPECTRAL RESPONSE
ACCELERATION PARAMETER (SDS)
DESIGN SPECTRAL RESPONSE
ACCELERATION PARAMETER (SD1)
1.0 -----------------------------------------
II --------------------------------------------
D -------------------------------------------
B -------------------------------------------
0.147g -----------------------------------
0.082g -----------------------------------
0.157g------------------------------------
0.131g------------------------------------
50 FT² 100 FT² 500 FT²
1500 PSF--------------------------------
125 PCI ----------------------------------
1.
2.
3.
4.
SUBMITTALS:
ALL SUBMITTED STRUCTURAL SHOP DRAWINGS WILL BE REVIEWED FOR
GENERAL CONFORMANCE WITH THE INFORMATION GIVEN AND DESIGN
CONCEPTS EXPRESSED IN THE CONTRACT DOCUMENTS. REVIEW OF
SUCH SUBMITTALS IS NOT CONDUCTED FOR THE PURPOSE OF
DETERMINING THE ACCURACY AND COMPLETENESS OF DETAILS SUCH AS
DIMENSIONS AND QUANTITIES AS REQUIRED BY THE CONTRACT
DOCUMENTS.
DEFERRED SUBMITTALS:
THE FOLLOWING ITEMS SHALL BE SUBMITTED TO THE BUILDING
OFFICIAL AS DEFERRED SUBMITTALS PER IBC SECTION 107.3.4.1:
FOR ALL DEFERRED STRUCTURAL SUBMITTALS, INCLUDE
CALCULATIONS PREPARED AND CERTIFIED BY A PROFESSIONAL
ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS
LOCATED. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL SHOP
DRAWING REQUIREMENTS.
A. METAL STAIRS, LADDERS AND RAILINGS
B. METAL BALCONIES, CANOPIES AND SUNSHADES
SOILS AND FOUNDATIONS:
FOUNDATIONS, RETAINING AND BASEMENT WALLS, SLABS ON GRADE
AND OTHER ITEMS RELATED TO THE SOILS ARE DESIGNED AND SHALL
BE CONSTRUCTED IN ACCORDANCE WITH THE RECOMMENDATIONS
OF ALT & WITZIG ENGINEERING, INC GEOTECHNICAL EVALUATION
REPORT 20IN0285 DATED JUNE 17, 2020 AND REVISED JUNE 22, 2020.
MINIMUM DEPTH FROM EXTERIOR GRADE TO BOTTOM OF BUILDING
PERIMETER FOOTINGS SHALL BE 36".
ALL FOOTINGS ARE CENTERED UNDER WALLS, PILASTERS AND
COLUMNS ABOVE UNO.
ALL FOUNDATION WALLS SHALL BE LATERALLY BRACED BEFORE
BACKFILLING AND COMPACTING.
DO NOT BACKFILL AROUND STEEL COLUMNS UNTIL CORROSION
RESISTANT ASPHALTIC COATING HAS BEEN INSTALLED BY THE
STRUCTURAL STEEL ERECTOR.
COORDINATE ALL UNDERGROUND PIPING OR DUCTWORK LOCATIONS
AND ELEVATIONS WITH THE MECHANICAL CONTRACTOR. ADJUST
FOOTING ELEVATIONS AND PROVIDE SLEEVES PER WALL FOOTING AT
UNDERGROUND LINES DETAIL. FOR PIPING OR DUCTWORK PARALLEL
TO FOOTING, BOTTOM OF FOOTING ELEVATION SHOULD BE NO
HIGHER THAN THE PIPE OR DUCTWORK INVERT ELEVATION PLUS THE
HORIZONTAL DISTANCE BETWEEN EDGE OF FOOTING AND EDGE OF
PIPING OR DUCTWORK. CONTRACTOR SHALL NOTIFY ARCHITECT AND
ENGINEER FOR APPROVAL OF ANY DEVIATIONS PRIOR TO
COMMENCING WORK.
1.
2.
3.
4.
5.
6.
DESIGN CODES: IBC CHAPTER 19 & ACI 318-11, BUILDING CODE
REQUIREMENTS FOR STRUCTURAL CONCRETE & ACI DETAILING
MANUALS LATEST EDITION.
MINIMUM COMPRESSIVE STRENGTH IS 28 DAYS.
CAST-IN-PLACE CONCRETE:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
TYPE STRENGTH
A ---------- f'c=3000 PSI -------------
B ---------- f'c=4000 PSI --------------
C ---------- f'c=4000 PSI --------------
D ---------- f'c=3000 PSI --------------
E ---------- f'c=4000 PSI --------------
F ---------- f'c=4500 PSI --------------
G ---------- f'c=4000 PSI --------------
H ---------- f'c=4000 PSI --------------
REINFORCING STEEL PROPERTIES:
A. DEFORMED BARS - ASTM A615 GRADE 60 UNO. USE ASTM A706
GRADE 60 FOR WELDABLE REBAR.
B. WELDED WIRE FABRIC - ASTM A1064.
LOCATION
MASONRY CORE FILL AND BOND
BEAMS W/ 3/8" MAX AGGREGATE SIZE
AND 8" TO 11" SLUMP
INTERIOR SLABS ON GRADE ≤5" DEEP
W/ 3/4" MAX AGGREGATE SIZE AND 3"
TO 5" SLUMP
INTERIOR SLABS ON GRADE > 5" DEEP
W/ 1 1/2" MAX AGGREGATE SIZE AND 3"
TO 5" SLUMP
FOOTINGS
PIERS AND FOUNDATION WALLS
EXPOSED EXTERIOR CONCRETE AIR
ENTRAINED 6% +/- 1%. MAX
WATER/CEMENT RATIO = 0.45.
CONCRETE TOPPING OVER STEEL
DECK
ALL OTHER CONCRETE W/ 3/4" MAX
AGGREGATE SIZE
ALL REINFORCING SHALL BE DETAILED, FABRICATED AND PLACED
IN ACCORDANCE WITH THE LATEST ACI MANUALS.
FOR PIERS WITH A CROSS SECTION LARGER THAN 18"x18" AND
WITH MORE THAN 4 LONGITUDINAL BARS, ADDITIONAL CROSS
TIES (TYPE T9 PER ACI 315) OF SAME SIZE AND SPACING AS
MAIN TIES, SHALL BE PROVIDED TO ENSURE THAT ALL NON
CORNER BARS ARE LATERALLY SUPPORTED BY THE CORNER
OF A TIE.
A.
SHOP DRAWINGS FOR REINFORCING STEEL AND CONCRETE MIX
DESIGNS SHALL BE SUBMITTED FOR APPROVAL. SUBMIT
PROPOSED LAYOUT OF SLAB ON GRADE
CONTROL/CONSTRUCTION JOINTS FOR APPROVAL.
PLACE ALL ITEMS PER APPROVED SHOP DRAWINGS AND
APPROVED MIX DESIGNS.
PROVIDE ALL ACCESSORIES, CHAIRS, SPACER BARS AND
SUPPORTS NECESSARY TO SECURE REINFORCING PER "ACI
DETAILING MANUAL" NO OTHER METHODS OR MATERIALS WILL BE
ACCEPTABLE.
PROVIDE PLASTIC CHAIRS AND SUPPORTS IN ALL AREAS OF
EXPOSED CONCRETE.
PROVIDE MINIMUM CONCRETE COVER FOR ALL REINFORCING AS
FOLLOWS UNO:
CONCRETE CAST AGAINST AND
PERMANENTLY EXPOSED TO EARTH
CONCRETE EXPOSED TO EARTH OR
WEATHER: #6 THROUGH #18 BARS
#5 BARS AND SMALLER
CONCRETE NOT EXPOSED TO WEATHER OR
IN CONTACT WITH GROUND:
SLABS, WALLS, JOISTS:
#14 AND #18 BARS
#11 BARS AND SMALLER
BEAMS, COLUMNS:
PRIMARY REINFORCEMENT,
TIES, STIRRUPS, SPIRALS
A.
B.
C.
-------------------------------- 3"
-------------------------------- 2"
--------------------------- 1 1/2"
--------------------------- 1 1/2"
-------------------- 3/4"
--------------------------- 1 1/2"
PROVIDE CONTINUOUS WALL FOOTING THICKNESS AND BOTTOM
REINFORCING AS FOLLOWS (PLACE LONGITUDINAL REINFORCING
ABOVE TRANSVERSE REINFORCING):
FOOTING WIDTH THICKNESS LONG REINF TRANSV REINF
1'-8" OR LESS 10" (2) #5 -------------
1'-9" TO 2'-8" 12" (2) #5 -------------
2'-9" TO 3'-4" 12" (3) #5 #4 @ 12" O.C.
3'-5" TO 4'-0" 12" (4) #5 #6 @ 12" O.C.
4'-1" TO 5'-0" 12" (5) #5 #7 @ 12" O.C.
5'-1" TO 6'-0" 14" (6) #5 #7 @ 12" O.C.
PROVIDE 100% VIRGIN POLYPROPYLENE FIBER REINFORCING IN ALL
INTERIOR CONCRETE SLABS ON GRADE UNO. (FIBERMESH 300,
MASTER FIBER F100, GENESIS FIBER, POLYMESH OR APPROVED
EQUAL). DOSAGE RATE TO BE PER MANUFACTURER'S
RECOMMENDATIONS.
PROVIDE FOOTING DOWELS FOR CONCRETE OR MASONRY WALLS
AND COLUMNS. DOWELS SHALL BE SAME SIZE AND SPACING AS
WALL AND COLUMN VERTICAL REINFORCING AND SHALL PROJECT
FROM FOOTINGS TO PROVIDE LAP SPLICES AS INDICATED BELOW
OR IN THE MASONRY NOTES. PROVIDE 90 DEGREE STANDARD HOOK
IN COLUMN AND FREE STANDING WALL FOOTING DOWELS UNO.
PROVIDE LAP SPLICES FOR CONCRETE REINFORCING AS FOLLOWS:
A. TYPICAL LAP SPLICES SHALL BE UNO:
#6 BARS AND SMALLER ----------------------- 44 BAR DIAMETERS
#7 THROUGH #11 BARS ----------------------- 56 BAR DIAMETERS
B. TENSION LAP SPLICES FOR CONCRETE RETAINING WALLS AND
BEAMS SHALL BE 1.3 TIMES TYPICAL LAP SPLICES.
C. FOR TOP BARS, THE SPLICE LENGTHS SHALL BE INCREASED
AN ADDITIONAL 1.3 TIMES THE LENGTHS DETAILED ABOVE.
D. THE MINIMUM LAP SPLICE LENGTH FOR ALL SPLICES FOR
CONCRETE REINFORCING SHALL BE 24".
PROVIDE MINIMUM CONCRETE WALL REINFORCING AS FOLLOWS
UNO:
WALL THICKNESS VERT REINF HORIZ REINF
6" AND 8" #4 @ 16" O.C. CTRD #4 @ 12" O.C. CTRD
10" #4 @ 16" O.C. EF #4 @ 16" O.C. EF
12" AND 14" #4 @ 12" O.C. EF #4 @ 12" O.C. EF
16" AND 18" #4 @ 12" O.C. EF #5 @ 16" O.C. EF
PROVIDE EXTRA REINFORCING ON ALL SIDES OF ALL CONCRETE
WALL AND SLAB OPENINGS EQUAL TO ONE HALF THE INTERRUPTED
REINFORCING IN EACH DIRECTION, UNO ON THE DRAWINGS. A
MINIMUM OF (1) #5 SHALL BE PROVIDED FOR EACH LAYER OF
REINFORCEMENT. EXTEND BARS PAST EDGE OF OPENING THE LAP
SPLICE NOTED ABOVE. PROVIDE AN ADDITIONAL #4x4'-0" DIAGONAL
BAR AT EACH CORNER FOR EACH LAYER OF REINFORCING.
HOT WEATHER AND COLD WEATHER CONCRETE PROVISIONS OF
ACI 305R-10 AND ACI 306R-16 SHALL BE FOLLOWED.
DESIGN CODES: IBC CHAPTER 21 AND ACI 530-11 MSJC-BUILDING
CODE REQUIREMENTS AND SPECIFICATION FOR MASONRY
STRUCTURES.
HOLLOW CONCRETE MASONRY UNITS SHALL BE NORMAL WEIGHT
UNITS PER ASTM C90 REQUIREMENTS. F'm=2000 PSI.
ALL MORTAR FOR LOAD BEARING WALLS BELOW GRADE SHALL BE
TYPE 'M' MORTAR. MORTAR FOR LOAD BEARING WALLS ABOVE
GRADE SHALL BE TYPE 'S'. TYPE 'N' MORTAR WILL BE ALLOWED FOR
INTERIOR ABOVE GRADE NON-LOAD BEARING PARTITIONS.
MORTAR PER ASTM C270. MINIMUM 28 DAY COMPRESSIVE
STRENGTH: TYPE 'M'=2500 PSI, TYPE 'S'=1800 PSI, TYPE 'N'=750 PSI.
COARSE GROUT PER ASTM C476. MINIMUM 28 DAY COMPRESSIVE
STRENGTH=3000 PSI. NO GROUT IS TO BE HAND MIXED ON SITE.
MASONRY CEMENT SHALL NOT BE USED IN MORTAR OR GROUT.
REINFORCING STEEL:
A. DEFORMED BARS: ASTM GRADE 60.
B. JOINT REINFORCEMENT: ASTM A82.
SUBMIT MORTAR AND GROUT DESIGN MIXES FOR APPROVAL.
SUBMIT SHOP DRAWINGS FOR REINFORCING STEEL.
PROVIDE MINIMUM 8" FULL DEPTH AND WIDTH BEARING FOR ALL
MASONRY LINTELS.
WIRE JOINT REINFORCING FOR CONCRETE BLOCK WALLS SHALL BE
STANDARD CORROSION RESISTANT 9 GAGE LADDER TYPE (PROVIDE
TRI-ROD LADDER FOR MULTI WYTHE WALLS). INSTALL JOINT
REINFORCING PER MANUFACTURER'S RECOMMENDATIONS AT A
MAXIMUM SPACING 16" O.C. UNO ON DRAWINGS OR PROJECT
SPECIFICATIONS.
INSTALL MASONRY VERTICAL AND HORIZONTAL REINFORCING PER
IBC REQUIREMENTS AND AS FOLLOWS:
A. SEE PLANS, DETAILS AND SCHEDULES FOR REQUIRED
REINFORCING.
B. PROVIDE FULL MORTAR BEDDED FACE SHELLS AND WEBS
AROUND ALL GROUTED CELLS FOR BEARING AND TO PREVENT
LEAKAGE INTO ADJACENT CELLS.
C. PLACE VERTICAL REINFORCING PRIOR TO PLACING GROUT.
D. PROVIDE REINFORCEMENT POSITIONERS TO HOLD VERTICAL
REINFORCEMENT IN PROPER POSITION AT TOP AND BOTTOM OF
ALL LIFTS. LENGTH OF REINFORCING BARS TO BE COORDINATED
WITH CONCRETE AND MASONRY CONTRACTORS.
E. GROUT ALL CORES CONTAINING REINFORCING SOLID.
F. MASONRY WALL CELLS TO BE GROUTED WITH CONCRETE SHALL
BE FILLED IN MAXIMUM 4'-0" LIFTS. REMOVAL ALL OVERHANGING
OBSTRUCTION AND DEBRIS FROM THE CELLS PRIOR TO
GROUTING.
G. CONSOLIDATE ALL GROUT BY RODDING OR VIBRATING.
H. PROVIDE REINFORCEMENT LAP SPLICES PER TABLES BELOW:
J. PROVIDE CORNER BAR WITH 2'-0" + 2'-0" LEGS FOR EACH
HORIZONTAL BOND BEAM BAR AT CORNERS AND INTERSECTING
WALLS.
PROVIDE CONTINUOUS BOND BEAMS WITH (2) #5 CONTINUOUS AT
THE TOP OF ALL BEARING AND END WALLS AS FOLLOWS:
A. WHEN SINGLE HEIGHT BOND BEAMS ARE USED, MAINTAIN
MINIMUM 8" HEIGHT.
B. WHERE JOIST BEARING BOND BEAMS, MASONRY LINTELS,
ETC. REQUIREMENTS EXCEED 8" HEIGHT. USE 16" HIGH
UNITS ONLY WHERE ACCEPTABLE FOR ARCHITECTURAL
AND VISUAL REQUIREMENTS. WHERE ARCHITECTURAL AND
VISUAL CONDITIONS AND REQUIRE USE OF 8" HIGH UNITS,
PLACE 8" HIGH POUR THROUGH UNITS ON TOP 8" HIGH
BOND BEAM UNIT. REINFORCE AND POUR THE BUILT UP
BOND BEAM AS ONE UNIT.
C. WHERE TOP OF BOND BEAM ELEVATIONS ARE NOT AT
MASONRY COURSING ELEVATIONS DUE TO JOIST, DECK OR
SLAB ELEVATIONS, ROOF SLOPES, ETC., PROVIDE BUILT UP
BOND BEAM AS DESCRIBED IN ITEM 'B' ABOVE. STEP BOND
BEAMS AS REQUIRED TO MAINTAIN A MINIMUM OF 8" BOND
BEAM HEIGHT. CUT OR NOTCH UPPER BOND BEAM UNIT.
REINFORCE AND POUR THE BUILT UP BOND BEAM PORTION
TO REQUIRED ELEVATIONS.
D. LENGTH AND HEIGHT OF ALL BOND BEAMS AND BUILT UP
BOND BEAM UNITS SHALL CONFORM TO ALL ARCHITECTURAL
AND VISUAL REQUIREMENTS.
E. SEE PLANS, SCHEDULES AND DETAILS FOR EMBEDDED
ANGLES, PLATES, ANCHOR BOLTS, ETC. CAST IN BOND
BEAMS, WALLS, PIERS ETC.
PROVIDE CONTINUOUS 8" HIGH x WALL THICKNESS BOND BEAM
WITH (2) #5 CONTINUOUS AT ALL MASONRY WALL BRICK LEDGE
ELEVATIONS.
GROUT SOLID BELOW ALL STEEL BEARINGS A MINIMUM OF FIVE
COURSES DOWN FOR 16" LENGTH OF WALL, UNO ON DRAWINGS.
ALL STEEL BEAMS SHALL BEAR A MINIMUM OF 8" ON SOLID
GROUTED MASONRY UNITS, UNO.
INSTALL LINTELS FOR ALL MASONRY WALL OPENINGS AS FOLLOWS,
UNO ON PLANS, DETAILS AND SCHEDULES:
A. PROVIDE ONE 8" HIGH COURSE LINTEL W/ (2) #5 BOTTOM FOR
ALL 2'-0" WIDE OR LESS OPENINGS IN LOAD BEARING MASONRY
WALLS AND ALL 4'-0" WIDE OR LESS OPENINGS IN NON-LOAD
BEARING MASONRY WALLS. PROVIDE TWO 8" HIGH COURSE
LINTEL W/ (2) #5 BOTTOM FOR SPANS UP TO 6'-4" IN NON-LOAD
BEARING WALL.
B. VERIFY SIZE AND LOCATIONS OF ALL MECHANICAL LOUVERS,
DUCTS AND ALL OTHER OPENINGS WITH MECHANICAL
CONTRACTOR AND OTHER CONCERNED DISCIPLINES.
C. SEE PLANS, SCHEDULES AND DETAILS FOR LINTEL TYPES AND
LOCATIONS. CONTACT ARCHITECT FOR LINTEL TYPE AND SIZE
FOR ALL REQUIRED OPENINGS GREATER THAN 2'-0' WIDE IN
LOAD BEARING WALLS NOT SHOWN ON STRUCTURAL PLANS,
DETAILS AND SCHEDULES.
MASONRY VERTICAL CONTROL JOINTS:
A. COORDINATE JOINTS AND CONSTRUCTION DETAILS WITH
ARCHITECT. MAXIMUM JOINT SPACING IS 24'-0".
B. LOCATE JOINTS 2'-0" FROM ALL CORNERS AND EDGE OF ALL
OPENING EXCEPT AS NOTED PER SECTIONS AND DETAILS.
C. FOR LOAD BEARING MASONRY, CONTINUE BOND BEAM
REINFORCING AND GROUT THROUGH CONTROL JOINTS.
D. FORM CONTROL JOINTS IN BLOCK WITH JAMB BLOCK WITH
NEOPRENE INSERTS, OR ROD AND CAULK. CONTRACTOR
OPTION: USE STANDARD BLOCK, LINE ONE SIDE WITH BUILDING
PAPER AND GROUT SOLID TO FORM KEYWAY.
E. PROVIDE CONTROL JOINTS AT INTERSECTIONS OF BEARING AND
NON-BEARING WALLS.
MASONRY:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
BARS CENTERED IN WALL
BAR SIZE 6" CMU 8" CMU 10" CMU & UNDER
#4
#5
#6
#7
24"
-----
-----
-----
24"
30"
38"
-----
24"
30"
36"
42"
BARS PLACED AT INSIDE OR OUTSIDE FACE OF WALL
BAR SIZE 6" CMU 8" CMU 10" CMU & UNDER
#4
#5
#6
#7
-----
-----
-----
24"
30"
57"
-----
24"
30"
36"
42"
-----
DESIGN CODES: IBC CHAPTER 22, AISC 360-10, SPECIFICATION FOR
STRUCTURAL STEEL BUILDINGS AND AISC 303-10, CODE OF
STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES.
STEEL PROPERTIES:
A. ASTM A992 (Fy=50 KSI) FOR WIDE FLANGE SHAPES
B. ASTM A500 GRADE B (Fy=46 KSI) FOR TUBULAR MEMBERS
C. ASTM A36 STEEL (Fy=36 KSI) FOR ALL OTHER MEMBERS UNO
D. ASTM F3125 GRADE A325 OR GRADE F1852 UNO FOR
CONNECTION BOLTS
E. ASTM F1554 GRADE 36 FOR ANCHOR BOLTS UNO
F. ASTM A108 FOR HEADED STUDS
G. WELDS = AMERICAN WELDING SOCIETY (AWS)
E70XX ELECTRODES
H. EXPANSION ANCHORS = HILTI KWIK BOLT 3 OR APPROVED
EQUAL
J. SCREW ANCHORS = SIMPSON TITEN HD OR APPROVED EQUAL
K. POWDER ACTUATED FASTENERS (PAF) = HILTI "X-U" OR
APPROVED EQUAL
PROVIDE 5000 PSI NON-SHRINK GROUT UNDER ALL STEEL BASE AND
BEARING PLATES PER THE SECTIONS AND DETAILS. GROUT PLATES
PRIOR TO LOADING ROOF MEMBERS WITH PRECAST PLANK OR
DECKING MATERIALS.
PROVIDE CORROSION RESISTANT ASPHALTIC COATING OR EQUAL
AROUND ALL STRUCTURAL STEEL BELOW GRADE.
ALL WELDS SHALL BE MADE BY CERTIFIED WELDERS AND IN
ACCORDANCE WITH AMERICAN WELDING SOCIETY (AWS) - D1.1
LATEST EDITION.
STRUCTURAL STEEL FABRICATOR SHALL FURNISH ALL PLATES AND
ANGLES CAST IN CONCRETE AND MASONRY FOR CONNECTING
STEEL JOISTS, BEAMS, COLUMNS, DECK, ETC. UNO. SEE APPLICABLE
NOTES ON THIS SHEET AND COORDINATE WITH MASONRY AND
CONCRETE CONTRACTORS.
ALL STEEL BEAMS AND LINTELS TO BEAR A MINIMUM OF 8" UNO.
ALL COLUMN BASE AND CAP PLATES TO BE WELDED AROUND ALL
SIDES.
PRIME PAINT PER AISC CODE OF STANDARD PRACTICE FOR STEEL
BUILDINGS SECTION 6.5, UNO ON ANY CONSTRUCTION DOCUMENTS.
CLEAN STEEL BUT OMIT PRIMER AT STEEL MEMBERS RECEIVING
SPRAY FIREPROOFING. COORDINATE W/ ARCH DRAWINGS.
ALL EXTERIOR LOOSE LINTELS AND BOTTOM PLATE LINTELS SHALL
BE HOT-DIP GALVANIZED.
STRUCTURAL STEEL FABRICATOR SHALL SUBMIT SHOP DRAWINGS
FOR APPROVAL.
MISCELLANEOUS STEEL FABRICATOR SHALL SUBMIT SHOP
DRAWINGS FOR APPROVAL, INCLUDING STRUCTURAL
CALCULATIONS FOR STAIRS, LADDERS, RAILINGS AND THEIR
CONNECTIONS CERTIFIED BY A PROFESSIONAL ENGINEER LICENSED
IN THE STATE WHERE THE PROJECT IS LOCATED.
PROVIDE BEAM CONNECTIONS AS SHOWN BELOW. ALTERNATE
CONNECTIONS WILL BE ALLOWED PROVIDED THAT CONNECTION
DESIGN CALCULATIONS, CERTIFIED BY A PROFESSIONAL ENGINEER
REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED, ARE
SUBMITTED BY THE FABRICATOR FOR REVIEW.
STEEL - STRUCTURAL:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
BOLTED/WELDED BEAM CONNECTION
REQUIREMENTS
...
. 3 1/2"DEPTHBEAMLENGTH(2) L 4x3 1/2
BEAM
SIZE
# OF 3/4"Ø A325
BOLTS EA SIDE
CONN ANGLES
THICKNESS LENGTH WELD SIZE
W36 10 3/8" 2'-5 1/2" 1/4"
W33 9 3/8" 2'-2 1/2" 1/4"
W30 8 3/8" 1'-11 1/2" 1/4"
W27 7 3/8" 1'-8 1/2" 1/4"
W24 6 3/8" 1'-5 1/2" 1/4"
W21 5 3/8" 1'-2 1/2" 1/4"
W18 4 3/8" 0'-11 1/2" 1/4"
W16 4 5/16" 0'-11 1/2" 1/4"
W14 3 0'-8 1/2" 1/4"
W12 3 0'-8 1/2" 1/4"
W10 2 0'-5 1/2" 1/4"
W8 2 0'-5 1/2" 1/4"
W6 1 0'-4" 3/16"
5/16"
5/16"
5/16"
5/16"
5/16"
NOTES:
USE E70XX ELECTRODES.
OUTSTANDING LEGS OF CONNECTION ANGLES MAY BE
REDUCED TO 3" WHEN BEAM FRAMES INTO W8 COLUMN WEB.
SEE TABLE FOR CONNECTION ANGLES, NUMBER OF BOLTS
AND WELD SIZES.
BOLTS SHALL BE TIGHTENED IN PROPERLY ALIGNED HOLES TO
A SNUG-TIGHT CONDITION AS DEFINED BY THE LATEST EDITION
OF AISC "SPECIFICATION FOR STRUCTURAL JOINTS USING
ASTM A325 OR A490 BOLTS" UNO.
USE BENT PLATES AS REQUIRED AT SKEWED BEAMS.
1.
2.
3.
4.
5.
DESIGN CODE: STEEL DECK INSTITUTE (SDI): "DESIGN MANUAL FOR
COMPOSITE DECKS, FORM DECKS AND ROOF DECKS" LATEST
EDITION.
STEEL DECK SHALL CONFORM TO ASTM A-653 OR A-446 AND HAVE A
MINIMUM YIELD STRENGTH OF 33,000 PSI AT ROOF DECK; 50,000 PSI
MINIMUM AT FLOOR DECK AND INTERIOR WALL PANELS. DECK SIZE,
TYPE AND GAUGE TO BE AS INDICATED ON PLANS.
FASTEN STEEL DECK TO ALL INTERIOR STEEL SUPPORTS AS SHOWN
ON PLANS. PROVIDE FASTENING AT 6" O.C. TO PLATE, ANGLE OR
BEAM AT BUILDING PERIMETER UNO. SIDELAP FASTENING SHALL BE
AS INDICATED ON PLANS.
SPAN DECK SECTION MINIMUM 3 SPANS CONTINUOUS, UNO.
THE STEEL DECK FABRICATOR SHALL SUBMIT SHOP DRAWINGS FOR
APPROVAL.
FLOOR DECK AND UNDERSIDE OF ROOF DECK SHALL BE GALANIZED
(G60 MIN), CONFIRM W/ ARCH. TOP OF ROOF DECK SHALL BE SHOP
PRIMED W/ STANDARD GRAY PRIMER.
CONCENTRATED LOADS IN EXCESS OF 75# SHALL NOT BE HUNG
DIRECTLY FROM ROOF DECK. CONCENTRATED LOADS 75# OR LESS
ARE ALLOWED BUT SHALL ONLY BE FASTENED TO THE SIDE OF DECK
FLUTES.
STEEL - DECK:
1.
2.
3.
4.
5.
6.
7.
DESIGN CODES:
A. IBC CHAPTER 22, SECTION 2210 AND 2211-COLD FORMED STEEL
AND LIGHT-FRAMING CONSTRUCTION. SEE PLANS FOR SIZE AND
THICKNESS OF STUDS.
B. 2010 AISI NORTH AMERICAN SPECIFICATIONS FOR THE DESIGN OF
COLD-FORMED STEEL STRUCTURAL MEMBERS.
SEE PLANS, ELEVATIONS, SECTIONS AND DETAILS FOR SIZE AND
THICKNESS OF STUDS. YIELD STRESS SHALL BE 33KSI FOR 33 MIL.
AND 43 MIL. MEMBERS AND 50KSI FOR ALL OTHER MEMBERS.
COLD FORMED STEEL FRAMING
600S162-43
.
.
.
.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
FLANGE WIDTH OF
MEMBER IN HUNDREDS
OF INCHES
(EX. 162=1 5/8", 200=2")
MEMBER THICKNESS IN
MILS
MEMBER DEPTH IN
HUNDREDS OF
INCHES
(EX. 600=6")
MEMBER TYPE
S=STUD,
T=TRACK
ALL STEEL STUD FASTENERS SHALL BE WELDED CONNECTIONS, OR
SHALL BE #10-16 "TEK" SCREWS MANUFACTURED BY "ITW BUILDEX"
OR APPROVED EQUAL UNO. ALL WELDS SHALL BE MADE BY
CERTIFIED WELDERS AND IN ACCORDANCE WITH AMERICAN
WELDING SOCIETY (AWS)-D13 LATEST EDITION. THE CENTER-TO-
CENTER SPACING AND EDGE DISTANCE FOR ALL SCREW
FASTENERS SHALL BE AT LEAST 3x (NOMINAL DIAMETER) UNO.
ALL POWDER ACTUATED FASTENERS (PAFS) SHALL BE HILTI "X-U"
OR APPROVED EQUAL UNO.
SPLICES IN WALL STUDS, JOISTS OR HEADERS SHALL NOT BE
PERMITTED UNLESS SPLICE CONNECTIONS ARE PROVIDED IN
SECTIONS AND DETAILS.
ALL FRAMING COMPONENTS SHALL BE CUT SQUARELY FOR
ATTACHMENT TO PERPENDICULAR MEMBERS, DO NOT TORCH CUT.
MEMBERS SHALL BE HELD POSITIVELY IN PLACE UNTIL PROPERLY
FASTENED.
STUDS SHALL BE PLUMBED, ALIGNED AND SECURELY ATTACHED TO
THE FLANGE OR WEB OF BOTH UPPER AND LOWER TRACKS. STUDS
SHALL HAVE FULL BEARING AGAINST INSIDE TRACK WEB PRIOR TO
STUD AND TRACK ATTACHMENT.
SEE ARCH FOR GYPSUM BOARD AND GYPSUM SHEATHING AT ALL
EXTERIOR WALLS. FASTEN TO STUDS WITH #6 MINIMUMx1" FLAT
HEAD SCREWS SPACED AT 12" O.C. AT PANEL INTERMEDIATE
SUPPORTS AND 6" O.C. AT PANEL EDGES.
WALL STUD BRIDGING SHALL BE ATTACHED IN A MANNER TO
PREVENT STUD ROTATION. BRIDGING ROWS SHALL BE SPACED AT
4'-0" O.C. MAXIMUM. INSTALLATION OF ALL REQUIRED WALL STUD
BRIDGING SHALL BE COMPLETED BEFORE ANY LOADS ARE APPLIED
TO THE SYSTEM.
CONTINUOUS TOP AND BOTTOM RUNNER TRACKS FOR ALL WALLS
SHALL BE FASTENED TO EACH STUD WITH (2) #10-16 SCREWS
MINIMUM UNO.
THE CONTRACTOR IS RESPONSIBLE FOR AVOIDING THE OVERLOAD
OF COLD FORMED STEEL MEMBERS DURING ERECTION AND FOR
PROVIDING ADEQUATE TEMPORARY BRACING UNTIL THE
PERMANENT BRIDGING AND SHEATHING ARE IN PLACE.
THE COLD FORMED STEEL SUPPLIER SHALL SUBMIT FOR APPROVAL
DETAILED SHOP DRAWINGS INDICATING MEMBER SIZES, THICKNESS,
SPACING AND ALL CONNECTIONS AS SHOWN ON THE DRAWINGS.
TOUCH-UP WELDS SHALL BE WITH ZINC-RICH PAINT PER ASTM A-780.
MILS TO GAUGE CONVERSION CHART
MILS
20 GA
18 GA
16 GA
14 GA
33
43
54
68
GAUGE
12 GA97
10 GA118
SPECIAL INSPECTION AND TESTING IS REQUIRED IN ACCORDANCE
WITH THE LATEST EDITION OF IBC, CHAPTER 17, FOR THE
FOLLOWING PORTIONS OF CONSTRUCTION:
SPECIAL INSPECTION AND TESTING:
1.
2.
3.
THE GENERAL CONTRACTOR SHALL SUBMIT A COMPLETED
"SPECIAL STRUCTURAL TESTING AND INSPECTION - PROGRAM
SUMMARY SCHEDULE" TO THE BUILDING OFFICIAL, ARCHITECT
AND ENGINEER PRIOR TO THE START OF CONSTRUCTION.
THE TESTING/INSPECTION AGENCY SHALL SUBMIT A FINAL
CERTIFIED REPORT AT SUBSTANTIAL COMPLETION INDICATING
THAT ALL WORK REQUIRING SPECIAL INSPECTIONS AND TESTING
HAS BEEN CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT
DOCUMENTS. A LIST OF ANY UNRESOLVED DEFICIENCIES SHALL
BE INCLUDED IN THIS REPORT.
CONCRETE
SOILS: GEOTECHNICAL ENGINEER SHALL FIELD VERIFY SOIL
BEARING CAPACITY AND COMPACTION PER THE
REQUIREMENTS OF THE GEOTECHNICAL REPORT.
SOILS: TESTING AGENCY SHALL FIELD VERIFY SOIL BEARING
CAPACITY AND COMPACTION PER THE REQUIREMENTS OF THE
GEOTECHNICAL ENGINEER.
CAST-IN-PLACE ANCHORS IN CONCRETE
POST-INSTALLED ANCHORS IN CONCRETE (PER PRODUCT ICC-
ESR REQUIREMENTS)
REINFORCING STEEL IN CONCRETE
CAST-IN-PLACE ANCHORS IN MASONRY
POST-INSTALLED ANCHORS IN MASONRY (PER PRODUCT ICC-
ESR REQUIREMENTS)
REINFORCING STEEL IN MASONRY - LEVEL B
STRUCTURAL WELDING - VISUAL TESTING (UNO)
HIGH STRENGTH BOLTING
IF THE STRUCTURAL STEEL AND/OR JOIST FABRICATOR IS NOT
AISC CERTIFIED, IN-SHOP SPECIAL INSPECTIONS ARE
REQUIRED AND SHALL BE PAID FOR BY THE FABRICATOR.
A.
B.
C.
D.
E.
F.
G.
H.
J.
K.
L.
STRUCTURAL ABBREVIATIONS:
& AND
@ AT (CL TO CL
SPACING)
CL CENTERLINE
Ø ROUND OR DIAMETER
# POUND OR NUMBER
AB ANCHOR BOLT
AD AREA DRAIN
ADD'L ADDITIONAL
ADDM ADDENDUM
ADJ ADJACENT
AFF ABOVE FINISHED FLOOR
ALT ALTERNATE
APPROX APPROXIMATE
ARCH ARCHITECTURAL/ITECT
B/O BOTTOM OF
BFE BOTTOM FOOTING
ELEVATON
BIT BITUMINOUS
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BOT BOTTOM
BRG BEARING
BSMT BASEMENT
BT BENT
BTWN BETWEEN
CANT CANTILEVER
CFS COLD FORMED STEEL
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLR CLEAR
CO CLEAN OUT
COL COLUMN
COMP COMPOSITE
CONC CONCRETE
CONN CONNECT/-ED/-ION
CONST CONSTRUCT/-ION
CONT CONTINUE/-OUS
CONTR CONTRACT/-OR
CMU CONCRETE MASONRY
UNIT
COORD COORDINATE
CTR, CTRD CENTER, CENTERED
CU FT CUBIC FEET
CY CUBIC YARD
DBL DOUBLE
DBL TEE, TT DOUBLE TEE
DEAD LD, DL DEAD LOAD
DEPT DEPARTMENT
DIA, Ø DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DN DOWN
DO DITTO
DP DEPTH OR DEEP
DR DOOR
DTL DETAIL
DWG DRAWING
DWLS DOWELS
EA EACH
EF EACH FACE
EJ, EXP JT EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EMBED EMBEDMENT,
EMBEDDED
EQ, = EQUAL
EQUIP EQUIPMENT
ERECT ERECTION
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
EW EACH WAY
FAB FABRICATE
FD FLOOR DRAIN
FDN FOUNDATION
FFE FINISHED FLOOR
ELEVATION
FIN FINISH
FLG FLANGE
FLR FLOOR
FP FIREPROOFING
FRMG FRAMING
FT, ' FOOT
FTG FOOTING
FV FIELD VERIFY
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN'L GENERAL
GLU-LAM, GL GLUE LAMINATED WOOD
GR BM GRADE BEAM
H HIGH
HD HEADED
HDR HEADER
HK HOOK
HORIZ HORIZONTAL
HT HEIGHT
HVAC HEATING, VENTILATION
AND AIR CONDITIONING
I/F INSIDE FACE
IE INVERT ELEVATION
IN, " INCH
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
INV INVERT
JBE JOIST BEARING
ELEVATION
JST JOIST
JT, JNT JOINT
K KIPS
KO KNOCK OUT
KSI KIPS PER SQUARE INCH
LB, # POUND
LD LOAD
LF LINEAL FOOT
LG, LGT LENGTH, LONG
LIVE LD, LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LOC LOCATION, LOCATE
LONG LONGITUDINAL
LSH LONG SIDE HORIZONTAL
LSL LAMINATED STRAND
LUMBER
LSV LONG SIDE VERTICAL
LT WT LIGHT WEIGHT
LVL LAMINATED VENEER
LUMBER
MAN MANUAL
MAS MASONRY
MAT'L MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MEZZ MEZZANINE
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MECHANICAL OPENING
MTL MATERIAL
#, NO. NUMBER
NA, N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
O/F OUTSIDE FACE
O.C. ON CENTER
OD OVERFLOW DRAIN
OH DR OVERHEAD DOOR
OPNG OPENING
OPP OPPOSITE
P&J PAN AND JOIST
P/C PRECAST CONCRETE
PAF POWDER ACTUATED
FASTENER
PART PARTITION
PL PLATE
PLBG PLUMBING
PLF POUNDS PER LINEAR
FOOT
PNL PANEL
PRELIM PRELIMINARY
PREP PREPARATION
PROJ PROJECT/-ION
PSF POUNDS PER SQUARE
FOOT
PSI POUNDS PER SQUARE
INCH
PT POST TENSION
QUAN, QTY QUANTITY
R RADIUS
RD ROOF DRAIN
REC RECESSED, RECOMMEND
REF REFERENCE
REINF REINFORCE/-ING/-ED
REQ'D REQUIRED
RET RETAINING
REV REVISION
RO ROUGH OPENING
SCHED SCHEDULE
SEC, SECT SECTION
SF, SQ FT SQUARE FOOT
SHT SHEET
SIM SIMILAR
SJI STEEL JOIST INSTITUTE
SL SNOW LOAD
SPA SPACES/-ING
SPEC SPECIFICATIONS
SQ SQUARE
SQ YD SQUARE YARD
STD STANDARD
STIFF STIFFENER/-S
STIR STIRRUPS
STL STEEL
STL JST STEEL JOIST
STOR STORAGE
STR, STRT STRAIGHT
STRUC(T) STRUCTURAL
SYM SYMMETRICAL
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
T/O TOP OF
TBE TOP OF BEAM ELEVATION
TDE TOP OF DECK ELEVATION
TFE TOP OF FOOTING
ELEVATION
TGE TOP OF GIRDER
ELEVATION
THRU THROUGH
TPE TOP OF PLANK
ELEVATION
TRANS(V) TRANSVERSE
TRTD TREATED
TSE TOP OF SLAB ELEVATION
TYP TYPICAL
TWE TOP OF WALL ELEVATION
UNFIN UNFINISHED
UNO UNLESS NOTED
OTHERWISE
VERT VERTICAL
W WIDE/WIDE FLANGE
W/ WITH
W/O WITHOUT
WD WOOD
WDW WINDOW
WP WORK POINT
WT WEIGHT
WWF WELDED WIRE FABRIC
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
Phone: 763.425.9960 Fax: 763.425.9958
5279 Kyler Avenue NE Albertville, MN 55301
SOLUTIONS, P.A.
STRUCTURAL
INNOVATIVE
Email: isspa@isseng.com Web: www.isseng.comISSISSISSPAISSPAPAPA
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
8-27-2020
JMW
MJV
08/27/2020
S001
GENERAL STRUCTURAL
NOTES
86220CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
STRUCTURAL DRAWING SHEET INDEX
S001 GENERAL STRUCTURAL NOTES
S101 FOUNDATION PLAN
S102 SECOND FLOOR FRAMING PLAN
S103 THIRD FLOOR FRAMING PLAN
S104 ROOF FRAMING PLAN
S201 SECTIONS AND DETAILS
S202 SECTIONS AND DETAILS
S203 SECTIONS AND DETAILS
# DESCRIPTION DATE
07/14/21
A B C D
11
22
33
4
5
6
77
8
9
10
1111
12
13
14
10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"
60' - 0"
A.1 B.1 C.1
10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"150' - 0"40' - 0" 40' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"3' - 6 3/16"7' - 6" 9' - 10 7/16" 8"8' - 1 3/8"8"9' - 4 3/16" 8"4" 11' - 5"
ELEV
OPNG
J1 J1
SEE 3/S201 FOR TYP
CONTROL/CONST
JT DETAIL
AREA A
AREA BS S S S
C1
C2
C6
C6
C6
C5
C5
C3
C3
7' - 6 3/4"
C2
C2
C2
C2
C2
C2
C2
C3
C3
6"
F2
C2
F2
F3
F3
F3
F2
F2 F4
F2
F2
F2
F2
F2
F2
F2
F4
F4
F1
F1
F1
J1
J1
10
S20110
S201
9
S201
9
S2019
S201 10
S201
13
S201
10
S201
10
S201
13
S201
13
S201
13
S201
8
S201
8
S201
13
S201
11
S201
11
S201
10
S201
11
S201
11
S201
8
S201
8
S201
8
S201
12
S201 12
S201 12
S201
18
S201
TYP 4
SIDES
4' - 0" 15' - 9" 4' - 0" 16' - 0" 4' - 0" 5' - 4" 3' - 9 5/8" 8' - 10 3/8"32' - 1 1/4" 75' - 10 15/16" 43' - 4 13/16" 5' - 0"1' - 9"1' - 9"8' - 0" 4' - 0" 16' - 0" 4' - 0" 76' - 0" 4' - 0" 16' - 0" 4' - 0" 15' - 9" 4' - 0"1' - 5"3' - 2 3/4"
5' - 4" 4' - 1"2' - 1 1/4"SW3
F2F1
A
#4 @ 24" O.C.
CONT BOT TYP
(2) #5 @ 16" O.C.
CTRD UNDER
EA BRG WALL
SW1 SW1 SW1
SW1 SW1 SW1
S S S STFE= 98' - 8"
TFE= 96' - 8"S S TFE= 96' - 8"TFE= 95' - 0"TFE= 96' - 8"W2
A
C
W1 W2
W2
W2
W2
W1
J1
J1 2'-6" FTGS S
2'-6" FTG
2'-6"FTG3'-0" FTG2'-6" FTG 5' - 0"5' - 0"1' - 0 3/4"5' - 4"1' - 6 3/8"5' - 8"3' - 6 3/4"5' - 4" 13
S201
12' - 0" 3' - 0"5' - 0"5' - 0"C3
F2
1.51.5
2.52.5
SIM
SIM
SIM
10
S201
SW3
4"
4"
4" 4"4"4"4"TYP8"8"20
S201
SIM
1' - 6 3/4"
15
S201
TYP
SIM
21
S201 TYP23
S201
20
S201 TYP @
COL
19
S201
TYP
15
S201
TYP
TFE= 98' - 8"12
S201
3'-0" FTG
C
C
30
S201
J2
20
S201
23
S201
15
S201
TYP
30
S201
TFE= 96' - 8"
SIM
1 1
A B C D
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
A.1 B.1 C.1
180' - 0"J2J1 J1
10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"SEE 3/S201 FOR TYP
CONTROL/CONST
JT DETAIL
AREA A
AREA B
10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"
C3
6"
C3
C3
C6
F1
F1
F1
F3
J1
8
S201
8
S201
9
S201
8
S201
9
S201
9
S201
30
S201
30
S201
13
S201
9
S201
11
S201
8
S201
11
S201
8
S201
11
S201
11
S201
8
S201
13
S201
12
S201
12
S201
12
S201
4' - 0"15' - 9" 4' - 0" 126' - 0" 3' - 5" 28' - 7"4' - 0" 15' - 9" 4' - 0" 126' - 0" 4' - 0" 16' - 0" 4' - 0" 8' - 0"
A
#4 @ 24" O.C.
CONT BOT TYP
(2) #5 @ 16" O.C.
CTRD UNDER
EA BRG WALL
SW1 SW1 SW1
SW1 SW1
SW1 SW1
A
2'-6" FTGW1
F2
C
W1
W2
S S
TFE= 98' - 8"
2'-6" FTG
S S
TFE= 98' - 8"
8
S201
2'-6" FTG
2'-6" FTGSIM
SIM
SIM
6' - 5" 3' - 11"4"4"4' - 0"4"4"4' - 0" 25' - 9" 4' - 0" 25' - 9" 4' - 0"
4"
17' - 11 1/2" 5' - 4"5' - 0"4"4"19' - 4 3/8" 8" 4' - 1"4 3/16"1' - 9"1' - 9"
SIM
TFE= 96' - 8"F1
8
S201
15
S201
TYP
15
S201
TYP
15
S201
TYP
20
S201
TYP @
COL
20
S201
SIM
9
S201
C2
F2
21
S201
1
1 1
1
1
1
12' - 0" 12' - 11"5' - 0"8"
FOUNDATION PLAN NOTES:
VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS.
SEE ARCH DRAWINGS FOR SIZE AND LOCATION OF ALL WALL OPENINGS.
FINISHED FLOOR ELEVATION (FFE) = 100'-0" UNO. VERIFY ALL DEPRESSED AND
SLOPED SLABS W/ ARCH DRAWINGS AND MECH/ELEC CONTRACTORS.
ALL CONTINUOUS WALL FOOTINGS SHALL BE 2'-0"W x 1'-0"D W/ (2) #5 CONTINUOUS
BOTTOM UNO. SEE PLAN FOR FOOTING WIDTHS GREATER THAN 2'-0" AND SEE
GENERAL NOTES FOR THICKNESS AND REINFORCING REQUIREMENTS.
TOP OF EXTERIOR FOOTING ELEVATION (TFE) = 96'-8" UNO.
TOP OF INTERIOR FOOTING ELEVATION (TFE) = 98'-10" UNO.
S----S ON PLAN DENOTES STEPPED FOOTING. SEE DETAIL 1/S201.
SEE SECTION 2/S201 FOR DROPPED FOOTING AT ALL UNDERGROUND
MECHANICAL LINES ENTERING BUILDING.
"CX" ON PLAN DENOTES STEEL COLUMN SIZE. SEE STEEL COLUMN SCHEDULE ON
THIS SHEET.
"FX" ON PLAN DENOTES FOOTING SIZE. SEE FOOTING SCHEDULE ON THIS SHEET.
ON PLAN DENOTES MASONRY JAMB. SEE JAMB REINFORCING SCHEDULE ON
THIS SHEET.
ON PLAN DENOTES MASONRY WALL REINFORCING. SEE WALL REINFORCING
SCHEDULE ON THIS SHEET.
ON PLAN DENOTES INTERIOR SHEAR WALL ABOVE. SEE SHEAR WALL
SCHEDULE ON THIS SHEET.
SEE COLD FORMED STEEL WALL SCHEDULE ON THIS SHEET FOR WALL FRAMING
REQUIREMENTS AT INTERIOR BEARING WALLS AND ALL EXTERIOR WALLS.
STEEL DECK SHEATHING AT INTERIOR WALLS SHALL BE 26 GA MINIMUM WITH
SECTION PROPERTIES EQUAL TO OR EXCEEDING THE FOLLOWING:
- HEIGHT = 7/16"
- I = 0.015 IN
4/FT
- S = 0.40 IN
3/FT
FASTENING TO STEEL STUDS SHALL BE #12 TEK SCREWS @ 8" O.C. (PANEL ENDS),
12" O.C. (INTERMEDIATE SUPPORTS) UNO IN SHEAR WALL SCHEDULE.
FOUNDATION KEYNOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
8" MINIMUM CONCRETE SLAB ON GRADE W/ FIBER REINFORCING. SEE PLAN FOR
ADDITIONAL REINFORCING.
NOT USED.
4" MINIMUM CONCRETE SLAB ON GRADE W/ FIBER REINFORCING.
NOT USED.
A
B
J-
SW-
W-
C
D
SHEAR WALL SCHEDULE NOTES:
FASTEN SHEATHING DIRECTLY TO WALL STUDS AND BLOCKING.
AT 'SW3', THE SHEATHING SHALL BE GYPSUM BOARD, SEE ARCH. FASTENING SHALL BE
#6 MINIMUM "TYPE S" x 1 1/4" FLAT HEAD SCREWS @ 6" O.C.
1.
2.
BEARING WALL SCHEDULE NOTES:
1.
2.
3.
4.
5.
SEE 7/S201 FOR REQUIRED WALL BRIDGING. SEE 27/S201 FOR FRAMING AT INTERSECTION OF
INTERIOR AND EXTERIOR WALLS.
STUD LOCATIONS SHALL BE ALIGNED FROM FLOOR TO FLOOR. MATCH SIZE AND LOCATION OF ANY
BEARING AND JAMB STUDS ABOVE.
SEE PLAN NOTES FOR STEEL DECK SHEATHING REQUIREMENTS AT INTERIOR WALLS.
SEE PLAN AND KEYNOTES FOR EXTERIOR WALL FRAMING AT THE LOADING BAY.
PROVIDE 600S200-68 @ 20" O.C. ALONG GRIDS 1.5 AND 2.
Phone: 763.425.9960 Fax: 763.425.9958
5279 Kyler Avenue NE Albertville, MN 55301
SOLUTIONS, P.A.
STRUCTURAL
INNOVATIVE
Email: isspa@isseng.com Web: www.isseng.comISSISSISSPAISSPAPAPA
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
8-27-2020
JMW
MJV
08/27/2020
S101
FOUNDATION PLAN
86220CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
1/8" = 1'-0"S101
1 FOUNDATION PLAN - AREA A
1/8" = 1'-0" S101
2 FOUNDATION PLAN - AREA B
SHEAR WALL SCHEDULE
MARK STUD FRAMING
STEEL DECK SHEATHING
FASTENING REMARKS
SW1 SEE BEARING WALL SCHED #12 TEK SCREWS @ 6" O.C.
SW2 400S250-54 @ 20" O.C. #12 TEK SCREWS @ 6" O.C.
SW3 SEE BEARING WALL SCHED N/A - SEE NOTE 2
COLD FORMED STEEL WALL SCHEDULE
LEVEL INTERIOR BRG WALL EXTERIOR WALLS
1ST LEVEL 400S250-97 @ 20" O.C., SEE NOTE #5 BELOW 600S200-54 @ 16" O.C.
2ND LEVEL 400S250-54 @ 20" O.C. 600S162-54 @ 16" O.C.
3RD LEVEL 400S250-54 @ 5'-0" O.C., 20" O.C. REQ'D
ALONG GRIDS 1.5 & 31
600S162-54 @ 16" O.C.
JAMB REINFORCING SCHEDULE
MARK VERT REINF WALL LENGTH
TERMINATING REINF
REMARKS VERTS LOCATION
J1 (1) #5 8" --- ---
J2 (3) #5 24" 1 LTL/BM BRG
WALL REINFORCING SCHEDULE
MARK BAR SIZE
SPA ON
CENTER LOCATION REMARKS
W1 #5 16" CTR
W2 #5 24" CTR
W3 #5 32" CTR
STEEL COLUMN SCHEDULE
MARK SIZE BASE PLATE REMARKS
C1 HSS 4X4X1/4 3/4" X 10" X 10"
C2 HSS 5X5X1/4 3/4" X 11" X 11"
C3 HSS 5X5X5/16 3/4" X 11" X 11"
C4 NOT USED ---
C5 HSS 6X6X3/8 1" X 12" X 12"
C6 HSS 8X8X3/8 1" X 14" X 14"
C7 HSS 4X4X 1/4 3/4" X 10" X BM WIDTH
FOOTING SCHEDULE
MARK SIZE BOT REINF EW REMARKS
F1 4'-6" X 4'-6" X 12" (5) #5
F2 6'-0" X 6'-0" X 14" (6) #6
F3 8'-6" X 8'-6" X 16" (8) #6
F4 11'-6" X 11'-6" X 20" (12) #6
N N
# DESCRIPTION DATE
1 BID ADDEN. 001 10/13/2020
1
1
1
1
1
07/14/21
VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS.
SEE ARCH DRAWINGS FOR SIZE AND LOCATION OF ALL WALL OPENINGS.
FINISHED FLOOR ELEVATION (FFE) = 113'-4".
TOP OF BEAM ELEVATION (TBE) AND DECK BEARING ELEVATION = 112'-11" UNO.
SEE DETAIL 1/S202 FOR TYPICAL FLOOR DECK FASTENING INFORMATION.
SEE COLD FORMED STEEL WALL SCHEDULE ON SHEET S101 FOR WALL FRAMING
REQUIREMENTS AT INTERIOR BEARING WALLS AND ALL EXTERIOR WALLS.
"CX" ON PLAN DENOTES STEEL COLUMN. SEE STEEL COLUMN SCHEDULE ON SHEET S101.
ON PLAN DENOTES MASONRY JAMB. SEE JAMB REINFORCING SCHEDULE ON
SHEET S101.
ON PLAN DENOTES LINTEL. SEE LINTEL SCHEDULE ON THIS SHEET.
ON PLAN DENOTES COLD FORMED STEEL HEADER. SEE COLD FORMED STEEL
HEADER SCHEDULE ON THIS SHEET.
ON PLAN DENOTES COLD FORMED STEEL BEAM. SEE COLD FORMED STEEL BEAM
SCHEDULE ON THIS SHEET.
ON PLAN DENOTES INTERIOR SHEAR WALL ABOVE. SEE SHEAR WALL SCHEDULE ON
SHEET S101
ON PLAN DENOTES MASONRY WALL REINFORCING. SEE WALL REINFORCING
SCHEDULE ON SHEET S101.
SEE 5/S202 FOR TYPICAL FLOOR OPENING SUPPORT REQUIREMENTS.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
SECOND FLOOR FRAMING PLAN NOTES:
SECOND LEVEL FRAMING KEYNOTES:
2" NORMAL WEIGHT CONCRETE SLAB W/ 6x6-W1.4xW1.4 WWF OVER 3"-20 GA COMPOSITE
DECK (5" TOTAL THICKNESS). NOTCH DECK AROUND COLUMNS AS REQUIRED. PROVIDE
CLOSURE PLATES AND POUR STOPS AS REQUIRED.
NOT USED.
2" NORMAL WEIGHT CONCRETE SLAB W/ 6x6-W1.4xW1.4 WWF OVER 3"-18 GA COMPOSITE
DECK (5" TOTAL THICKNESS) AT HATCHED AREA THUS: . NOTCH DECK AROUND
COLUMNS AS REQUIRED. PROVIDE CLOSURE PLATES AND POUR STOPS AS REQUIRED.
A
L_
J-
SW-
B
H_
W-
B_
C
A B C D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
A.1 B.1 C.1
AREA A
AREA B
10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"
60' - 0"10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"150' - 0"ELEV
OPNG
J1 J1
L1
STAIR
OPNG
L1 W8X18
OPEN
TO
BELOW
W21X50
W21X50
W21X50
W21X50
W21X50
W21X50
W21X50
W21X50
7' - 6 3/4"
W21X50
W21X50
W21X50
1' - 6 3/4"
W18X35
5' - 0"W24X68 CONTW24X117 5' - 0" CONT W24X131 W36X135 B1
B1
B1 B1
B1B1
B1 B1
B1B1
B1B1
B1
B1
B1
B1
B1
B1 B1 H6 H2 H2
AA AH4H4 H11H11H11
H11
SW1
SW1
L1J1
J1
W2
W2
W2
W1
W2
W2
W2
MO H6W16X31W16X31
1.5
2.5
7
S202
B1
B1
3' - 6 3/16"7' - 6" 9' - 10 7/16" 8"
4" 11' - 5" 9' - 0" TYP8"8"
10
S202
10
S202
CANOPY BY OTHERS,
SEE ARCH
CANOPY BY
OTHERS,
SEE ARCH
15
S202
21
S202
15
S202
SIM
23
S202
TYP @ BM
12
S202
TYP 18
S202
19
S202
17
S202
11
S202
TYP
11
S202
TYP
11
S202
TYP
19
S202
21
S202 TYP @
BM 16
S201
14
S202
26
S201 16
S20117
S201
13
S202
22
S202
25
S202
C12
S202
SIM16
S201
16
S201
16
S201
22
S202 SIMTYP
10
S202
10
S202
22
S202
SIM SIM
7
S202
27
S202
1
SEE 5/S202
28
S202
28
S202
1
28
S202
1
L3
SIM
1
9
S202
1
L4H6 LOW& TBE=116'-4" 22
S202
SIM
EA END
A B C D
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
A.1 B.1 C.1
AREA A
AREA B
180' - 0"10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"
L1
STAIR
OPNG
J1 J1 W36X135OPEN
TO
BELOW
L1
B1 B1
B1 B1
B1 B1
B1 B1
B1 B1
B1 B1
B1 B1
B1 B1
B1 B1
B1 B1
B1 B1
B1 B1
B1 B1
B1 B1
B1 B1
B1 B1
B1 B1
L3
W2
W2
W1
W1AA SW1
SW1
MO
AH7
5' - 10 5/8" 19' - 4 3/8"3 13/16"6"
SW1
A 14
S202
16
S202
22
S202
7
S202
TYP
17
S201
16
S201
16
S201
16
S2018
S202
7
S202TYP
11
S202
TYP
11
S202
TYP
11
S202
TYP
11
S202
TYP 22
S202
SIM
EA END
1
25
S202
7
S202
7
S2021
SEE 5/S202
7
S202
H2 H4H12
W16X31
1
12
S202
11
S202
26
S201
21
S202
8"
7
S202
10
S202
COLD FORMED STEEL HEADER SCHEDULE NOTES:
SEE 2/S202 FOR TYPICAL HEADER DETAIL.1.
LINTEL SCHEDULE NOTES:
1.
2.
3.
4.
SEE GENERAL MASONRY NOTES ON SHEET S001 AND FOUNDATION PLAN FOR
REINFORCING NOT LISTED IN LINTEL SCHEDULE.
SEE GENERAL MASONRY NOTES ON SHEET S001 FOR ALL OTHER OPENINGS NOT
LISTED IN THE LINTEL SCHEDULE.
VERIFY ALL SPANS OF OPENINGS AND WALL THICKNESSES WITH ARCH DRAWINGS.
NOTIFY ARCHITECT/ENGINEER OF DEVATIONS PRIOR TO FABRICATION AND ERECTION.
LOOSE BRICK LINTELS SHALL BE HOT DIP GALVANIZED AND SHALL BEAR 6" MINIMUM AT
EACH END OF OPENING.
COLD FORMED STEEL BEAM SCHEDULE NOTES:
SEE 4/S202 FOR TYPICAL BEAM DETAIL.1.
Phone: 763.425.9960 Fax: 763.425.9958
5279 Kyler Avenue NE Albertville, MN 55301
SOLUTIONS, P.A.
STRUCTURAL
INNOVATIVE
Email: isspa@isseng.com Web: www.isseng.comISSISSISSPAISSPAPAPA
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
8-27-2020
JMW
MJV
08/27/2020
S102
SECOND FLOOR FRAMING
PLAN
86220CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff -Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
N N
1/8" = 1'-0"S102
1 SECOND FLOOR FRAMING PLAN - AREA A
1/8" = 1'-0"S102
2 SECOND FLOOR FRAMING PLAN - AREA B
COLD FORMED STEEL HEADER SCHEDULE
MARK HEADER SIZE
TOP & BOT
TRACK
BRG STUDS
(JACK STUDS)
JAMB STUDS
(KING STUDS)
END WEB
STIFF Y/N REMARKS
H1 1400S250-118 600T200-68 (2) 600S200-54 (2) 600S200-54 Y
H2 1600S300-118 600T200-68 (2) 600S250-68 (2) 600S250-68 Y
H3 NOT USED --- --- --- --
H4 1200S200-68 600T200-68 (2) 600S162-68 (2) 600S250-68 Y
H5 1200S200-68 600T200-68 (2) 600S162-68 (2) 600S200-54 Y
H6 600S162-54 600T125-54 (1) 600S162-54 (2) 600S200-68 N
H7 600S200-97 400T125-54 (1) 400S250-97 (1) 400S250-97 Y
H8 600S200-68 400T125-54 (1) 400S250-54 (1) 400S250-54 Y
H9 1000S200-97 400T125-54 (2) 400S250-54 (1) 400S250-54 Y
H10 800S200-68 400T125-54 (1) 400S250-54 (1) 400S250-54 Y
H11 600S200-97 600T125-54 (1) 600S200-68 (1) 600S200-54 Y
H12 1400S250-118 400T125-54 (2) 400S250-97 (2) 400S250-54 Y
LINTEL SCHEDULE
MARK REFERENCE MEMBER REMARKS
L1 28/S201 16"H BOND BM W/ (2)#5 CONT BOT
L2 --- NOT USED
L3 --- L 6 X 4 X 3/8" LLV LOOSE BRICK LINTEL
L4 --- L 8 X 4 X 7/16" LLV LOOSE BRICK LINTEL
COLD FORMED STEEL BEAM SCHEDULE
MARK BEAM SIZE JAMB STUDS FASTENERS PER MEMBER EA END REMARKS
B1 (2) 800S200-97 (2) 400S250-97 (10) #12-14
B2 (2) 800S200-68 (2) 400S250-54 (8) #12-14
B3 NOT USED --- ---
# DESCRIPTION DATE
1 BID ADDEN. 001 10/13/2020
1
1
1
1
1
1
07/14/21
A B C D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
A.1 B.1 C.1
AREA A
AREA B
10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"
9" 60' - 0" 9"10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 20' - 0" 20' - 0"150' - 0" 9"ELEV
OPNG
J1 J1
L1
STAIR
OPNG
6"
W12X16
W12X16
W12X16
W12X16 W36X135 W18X40B2
B2
B2
B2
B2 B2
B2 B2
B2 B2
B2 B2
B2 B2
B2 B2
B2 B2
B2 B2
B2
B2
B2
B2B2 AA AH2 H2 H5H5 H2
H5H5 SW2 SW2
MO
L1J1
J1
W2
W3
W2
W2
W3
W2
W2
1.5
2.5
H10 H9 H9 H9 H10
SW2 SW2
C7
W16X31
10
S202
10
S202
10
S202
10
S202
10
S202
10
S202
10
S202
11
S202
TYP
11
S202
TYP
11
S202
TYP
16
S201
16
S20117
S201
16
S201
16
S201
16
S201
21
S202
C23
S202
TYP @ BM
12
S202
SIM22
S202 SIM8
S202
8
S202
7
S202TYP
7
S202
TYP
SEE 5/S202
1
SIM
16
S201
SIM
29
S202
1
20
S202
21
S202
12
S202
TYP
30
S202 1
26
S202
1
A B C D
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
A.1 B.1 C.1
AREA A
AREA B
9" 180' - 0"10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"
J1 J1
L1
STAIR
OPNG
W12X16
W36X135W12X16
W12X16
6"
5' - 10 5/8" 19' - 4 3/8"3 13/16"B2B2
B2 B2
B2B2
B2B2
B2B2
B2B2
B2B2
B2B2
B2B2
B2B2
B2B2
B2B2
B2B2
B2B2
B2
B2B2
B2
H5ASW2
MO A ASW2
SW2
W2
W3
W2
W1
H10
11
S202
TYP
11
S202
TYP
11
S202
TYP
11
S202
TYP
23
S202
TYP @ BM
21
S202
17
S201
10
S202
7
S202TYP
16
S201
3 SIDES
8
S202
8
S202
29
S202
1
26
S202
27
S202
SIM
24
S202
24
S202
12
S202
TYP
16
S202
SIM
7
S202
TYP
1
SEE 5/S202
B2
B2
H10H9
1
H5 10
S202
7
S202
7
S202
FINISHED FLOOR ELEVATION (FFE) = 124'-0".
TOP OF BEAM ELEVATION (TBE) AND DECK BEARING ELEVATION = 123'-7" UNO.
SEE SHEET S102 FOR TYPICAL FLOOR FRAMING NOTES AND KEYNOTES.
1.
2.
3.
THIRD FLOOR FRAMING PLAN NOTES:
Phone: 763.425.9960 Fax: 763.425.9958
5279 Kyler Avenue NE Albertville, MN 55301
SOLUTIONS, P.A.
STRUCTURAL
INNOVATIVE
Email: isspa@isseng.com Web: www.isseng.comISSISSISSPAISSPAPAPA
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
8-27-2020
JMW
MJV
08/27/2020
S103
THIRD FLOOR FRAMING
PLAN
86220CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
N N
1/8" = 1'-0"S103
1 THIRD FLOOR FRAMING PLAN - AREA A
1/8" = 1'-0"S103
2 THIRD FLOOR FRAMING PLAN - AREA B
# DESCRIPTION DATE
1 BID ADDEN. 001 10/13/2020
07/14/21
A B C D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
A.1 B.1 C.1
AREA A
AREA B
10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"
60' - 0"10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"150' - 0"L1A
ACTYP
CTYP
C TYP
H1 H1 H4H4 H4H4 CTYP
14
S203
14
S203
14
S203
14
S203
9
S203
8
S203
H1
13
S203
13
S203
13
S203
@ WDW @ WDW @ WDW
@ WDW
@ WDW
@ WDW
@ WDW
9
S203
14
S203
@ WDW
14
S203
@ WDW
9
S2035
S203
TYP
5
S203
TYP
5
S203
TYP
5
S203TYP
5
S203
TYP L1W8X13A B12
S203
11
S203
12
S203
3
S203
6
S203
6
S203
7
S203
14
S203
@ WDW
14
S203
@ WDW
1.5
2.5
DECK BRG EL @
GRID A = 134'-8"
DECK BRG EL @
GRID D = 135'-11"
DECK BRG
ELEV=138'-0"
DECK BRG
ELEV=138'-4"
ROOF HATCH,
SEE ARCH
MECH UNIT 3100#
VERIFY WT, SIZE
& LOC W/ MECH
MO MO
H4 H4 W14X22
7
S203
H4 H4 11
S203
10
S203
TYP 3
LOC
STL CHANNEL
SUPPORT, SEE
2/S203
H8 H8 H8 H8 H8
21
S202
21
S202
A B C D
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
A.1 B.1 C.1
AREA A
AREA B
180' - 0"10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"
L1H4 H4CTYP
CTYP
CTYP AA A14
S203
@ WDW
14
S203
@ WDW
9
S203
14
S203
@ WDW
14
S203@ WDW
14
S203@ WDW
9
S203
5
S203
TYP
5
S203
TYP
5
S203
TYP
5
S203
TYP
12
S203
11
S203
12
S203
4
S203
8
S203
DECK BRG EL @
GRID A = 134'-8"
DECK BRG EL @
GRID D = 135'-11"
MECH UNIT 3100#
VERIFY WT, SIZE
& LOC W/ MECH
MO MOH4 H4H4STL CHANNEL
SUPPORT, SEE
2/S203
15
S203
@ WDWH4H8 H8H8
15
S203
@ WDW
21
S202
ROOF FRAMING PLAN NOTES:
VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS.
DECK BEARING ELEVATION = VARIES, SEE PLAN.
SEE DETAIL 1/S203 FOR ROOF OPENING SUPPORT FRAME DETAIL AT ROOF
OPENINGS(INCLUDING ROOF HATCHES, DRAINS AND MECHANICAL OPENINGS (MO)).
SEE DETAIL 2/S203 FOR MECHANICAL UNIT SUPPORT DETAIL.
MECHANICAL UNIT WEIGHTS AND SIZES SHOWN ON PLAN INDICATE THE MAXIMUM WEIGHT
AND SIZE PERMITTED. MECHANICAL CONTRACTOR SHALL NOTIFY ENGINEER OF RECORD IF
ANY UNIT WEIGHTS OR SIZES EXCEED THOSE SHOWN ON PLAN, OR IF ANY UNIT LOCATION
DIFFERS FROM THE LOCATION SHOWN ON PLAN.
3" ROOF DECK FASTENING SHALL BE #12 TEK SCREWS (AT CFS SUPPORTS) OR 5/8"Ø PUDDLE
WELDS (AT STRUCTURAL STEEL SUPPORTS) W/ 24/4 PATTERN. FASTEN DECK TO SUPPORTS
AT 8" O.C. AT BUILDING PERIMETER. SIDELAP FASTENERS SHALL BE (6) #10 TEK SCREWS
EQUALLY SPACED BETWEEN SUPPORTS.
ON PLAN DENOTES LINTEL. SEE LINTEL SCHEDULE SHEET S102.
ON PLAN DENOTES COLD FORMED STEEL HEADER. SEE COLD FORMED STEEL HEADER
SCHEDULE ON SHEET S102.
1.
2.
3.
4.
5.
6.
7.
8.
ROOF FRAMING KEYNOTES:
3"-20 GA TYPE 'N' ROOF DECK.
PROVIDE 2" CLEAR FROM TOP OF HOIST BEAM TO UNDERSIDE OF ROOF DECK. COORDINATE
LOCATION W/ ELEVATOR SUPPLIER.
WALL TOP TRACK ASSEMBLY (SEE 5/S203) TO SPAN CONTINUOUS OVER WALL OPENING. NO
HEADER REQUIRED.
A
B
C
L_
H_
Phone: 763.425.9960 Fax: 763.425.9958
5279 Kyler Avenue NE Albertville, MN 55301
SOLUTIONS, P.A.
STRUCTURAL
INNOVATIVE
Email: isspa@isseng.com Web: www.isseng.comISSISSISSPAISSPAPAPA
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
8-27-2020
JMW
MJV
08/27/2020
S104
ROOF FRAMING PLAN
86220CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff -Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
1/8" = 1'-0"S104
1 ROOF FRAMING PLAN - AREA A
1/8" = 1'-0"S104
2 ROOF FRAMNG PLAN - AREA B
N N
# DESCRIPTION DATE
07/14/21
07/14/21
07/14/21
07/14/21
BASE MATERIAL
CONCRETE OR
CONCRETE BLOCK
GYPSUM
CONCRETE OR
CONCRETE BLOCK
GYPSUM
BASIS OF DESIGN: HILTI CONSTRUCTION CHEMICALS, INC.
PENETRATING ITEM
METAL PIPE
STEEL, COPPER, CONDUIT OR EMT
(SLEEVED OR UNSLEEVED)
STEEL, COPPER, CONDUIT OR EMT
STEEL, COPPER, CONDUIT OR EMT
STEEL, COPPER, CONDUIT OR EMT
STEEL, COPPER, CONDUIT OR EMT
(SLEEVED)
STEEL, COPPER, CONDUIT OR EMT
INSULATED METAL PIPES
STEEL, COPPER, CONDUIT OR EMT
W/ GLASSFIBER INSULATION
(SLEEVED OR UNSLEEVED)
STEEL, COPPER, CONDUIT OR EMT
W/ AB/PVC INSULATION
(SLEEVED OR UNSLEEVED)
STEEL, COPPER, CONDUIT OR EMT
PIPE W/ GLASSFIBER INSULATION
IN A SLEEVE
STEEL, COPPER, CONDUIT OR EMT
W/ GLASSFIBER INSULATION
STEEL, COPPER, CONDUIT OR EMT
W/ AB/PVC INSULATION
STEEL, COPPER, CONDUIT OR EMT
W/ GLASSFIBER INSULATION
(SLEEVED OR UNSLEEVED)
STEEL, COPPER, CONDUIT OR EMT
PIPE W/ GLASSFIBER INSULATION
IN A SLEEVE
FIRE RATING
3 HR
4 HR
1 OR 2 HR
1 OR 2 HR
2 HR
4 HR
2 HR
3HR
4 HR
1 OR 2 HR
1 OR 2 HR
1 OR 2 HR
4 HR
UL SYSTEM
NO.
CAJ 1155
CAJ 1226
WJ 1042
WL 1054
WL 1085
WL 1058
WL 1110
CAJ 5091
CAJ 5090
WJ 5029
WL 5029
WL 5028
WL 5025
WL 5073
APPROVED EQUALS: PRODUCT OF EQUIVALENT CHARACTERISTICS UL COMPLIANT WITH UL 1479 AND UL 2079, ASTM E1339.
BASIS OF DESIGN
HILTI PRODUCT
FS-ONE
FS ONE
FS ONE
FS ONE
FS ONE
FS ONE
FS ONE
FS ONE
FS ONE
FS ONE
FS ONE
FS ONE
FS ONE
W/ COLLAR
FS ONE
CONCRETE OR
CONCRETE
BLOCK
GYPSUM
CONCRETE OR
CONCRETE BLOCK
GYPSUM
JOINTS
CONCRETE BLOCK WALL TO METAL
DECK (TOP OF WALL)
GYPSUM WALL TO METAL DECK
(TOP OF WALL TO ROOF) D13/A601
(TOP OF WALL TO FLOOR)
PLASTIC & GLASS PIPE
PVC, CPVC (CLOSED SYSTEM ONLY)
PVC, CPVC , ABS, FRPP
GLASS PIPE
MAX 6" PVC, CPVC, ABS, FRPP
(IN A SLEEVE)
PVC, CPVC (CLOSED SYSTEM ONLY)
PVC, CPVC, ABS, FRPP
(CLOSED SYSTEM ONLY)
2 HR
1 OR 2 HR
1 OR 2 HR
3 HR
3 HR
3 HR
3 HR
1 OR 2 HR
1 OR 2 HR
HWD-0008
HWD-1011
HWD-1003/-1011
CAJ 2141
CAJ 2109
CAJ 2118
CAJ 2110
WL 2098
WL 2078
WL 2075
FS ONE
CP 601 OR
FS ONE
FS ONE
CP 642
FS ONE
CP 642
FS ONE
CP 642
FS ONE
SCOPE DRAWINGS AND SPECIFICATIONS, AS DEFINED BY THE INDIANA
CONSTRUCTION INDUSTRY COUNCIL’S GUIDELINES,
A. THE CONTRACTOR SHALL OBSERVE THE FOLLOWING:
NOTHING SET FORTH IN THESE DRAWINGS SHALL RELEASE ANY CONTRACTOR FROM
RESPONSIBILITY TO PROVIDE APPROPRIATE QUANTITIES, FIELD MEASUREMENTS,
DIMENSIONAL STABILITY, INSTALLATION, ANCHORAGE AND COORDINATION WITH
OTHER TRADES, OR WAIVE THE CONTRACTOR'S RESPONSIBILITY TO IDENTIFY AND
RESOLVE DEVIATIONS FROM THE REQUIREMENTS OF THE CONTRACT DOCUMENTS,
OR WAIVE THE CONTRACTOR'S RESPONSIBILITY TO ALERT THE ARCHITECT TO ERRORS
OR OMISSIONS CONTAINED THEREIN.
CONTRACTOR SHALL VERIFY IN THE FIELD ALL EXISTING APPLICABLE CONDITIONS
AND DIMENSIONS SHOWN ON THE DRAWINGS AND AS PERTINENT TO THE INTENT OF
THESE DRAWINGS. ANY DISCREPANCY DISCOVERED SHALL BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK
AFFECTED BY, OR RELATED TO, SUCH DISCREPANCY.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH, OR CAUSED
BY FAILURE TO COMPLY WITH REQUIREMENT.
CONTRACTOR SHALL REVIEW IN ADVANCE ALL PORTIONS OF THE WORK TO VERIFY
THAT THE WORK WILL NOT PROHIBIT COMPLETION OF THE PROJECT AS INTENDED IN
THESE CONTRACT DOCUMENTS. ANY QUESTIONS SHALL BE PROMPTLY REFERRED TO
THE ARCHITECT FOR RESOLUTION.
CONTRACTOR SHALL REFER TO THE PROJECT MANUAL FOR CLEANING AND
DISPOSAL REQUIREMENTS.
CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL SURFACES AND
FINISHES AT INTERIOR AND EXTERIOR OF BUILDING. DAMAGED SURFACES AND
FINISHES RESULTING FROM THE PERFORMANCE OF THE WORK SHALL BE REPAIRED AT
NO COST TO THE OWNER BY THE RESPONSIBLE CONTRACTOR TO MATCH EXISTING TO
THE SATISFACTION OF THE OWNER.
CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WITH ALL ASPECTS OF THE
WORK, EVEN THOSE AREAS DESIGNATED TO BE PROVIDED BY OTHERS. THIS
FAMILIARIZATION INCLUDES FULL AND COMPLETE UNDERSTANDING OF THE WORK
DESCRIBED ON ALL SHEETS OF THE DRAWINGS AND IN ALL SECTIONS OF THE PROJECT
MANUAL. FAILURE BY THE CONTRACTOR TO BECOME COMPLETELY FAMILIAR AND
COGNIZANT OF ALL ASPECTS OF THE WORK SHALL NOT RELIEVE THE CONTRACTOR
OF THE RESPONSIBILITY TO PROVIDE MATERIALS, ASSEMBLIES, OR SERVICES
INDICATED IN THE CONTRACT DOCUMENTS.
B. THE CONTRACTOR SHALL PROVIDE THE FOLLOWING:
ALL MATERIAL AND EQUIPMENT OF INDUSTRY STANDARD QUALITY, SPECIFIED OR
NOT, AND WITH THE LIMITATION OF THE CONTRACT DOCUMENTS TO CAUSE THE
INSTALLATION TO FUNCTION IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE
OF THE FINISHED PROJECT.
ALL MATERIAL NECESSARY FOR EQUIPMENT TO FUNCTION IN A NORMAL AND
ACCEPTABLE MANNER.
ALL WORK REQUIRED TO CAUSE CONTRACTOR’S OPERATIONS TO FIT AND
COORDINATE WITH OTHER TRADES.
ALL WORK REQUIRED TO COMPLY WITH GOVERNING CODES WITH RESPECT TO
CONTRACTOR’S ACTIVITY, EXCEPT FOR DESIGN CRITERIA INVOLVING CAPACITIES
AND BASIC DESIGN.
WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE SIZING OF
INTERCONNECT FACILITIES, SUCH AS DUCTS AND WIRING IN PIECES OF EQUIPMENT
IN ORDER TO UTILIZE THE SPECIFIED CAPACITIES OF THE EQUIPMENT.
WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS ESTABLISHED
BY THE RECOGNIZED TRADE ASSOCIATION HAVING JURISDICTION FOR THE PRODUCT
INCLUDED IN THE PROJECT SHALL GOVERN THE WORK.
ALL UNSPECIFIED FIXTURES, ACCESSORIES AND / OR EQUIPMENT PROVIDED BY THE
CONTRACTOR SHALL HAVE CUT SHEETS / DRAWINGS SUBMITTED TO THE ARCHITECT
FOR APPROVAL.
GENERAL PROJECT NOTES
A. DO NOT SCALE THE DRAWINGS. REFER DISCREPANCIES TO ARCHITECT FOR
FINAL DECISIONS.
B. ALL DIMENSIONS SHOWN ARE TOFACE OF STUD TO FACE OF STUD UNLESS
NOTED OTHERWISE. DIMENSIONS DESIGNATED AS "CLR OR "CLEAR" INDICATE A
CLEAR DIMENSION FROM FACE OF FINISH TO FACE OF FINISH.
C. PROVIDE BRACING AND WOOD BLOCKING AS REQUIRED IN WALLS
SUPPORTING CASEWORK, TACKBOARDS, MARKERBOARDS, RESTROOM
ACCESSORIES, ETC.
D. SEAL ALL JOINTS BETWEEN DISSIMILAR MATERIALS.
E. ALL GYPSUM WALLBOARD IS 5/8" TYPE "X" UNLESS NOTED OTHERWISE. PROVIDE
MOISTURE AND MOLD RESISTANT GYPSUM WALLBOARD IN LOADING BAY,
JANITOR CLOSETS, AND RESTROOMS.
F. WHERE MOUNTING HEIGHTS ARE NOT INDICATED, MOUNT INDIVIDUAL UNITS
OF WORK AT INDUSTRY RECOGNIZED STANDARD MOUNTING HEIGHTS, ADA
AND ANSI A117.1 FOR THE PARTICULAR APPLICATION AND REFER
QUESTIONABLE MOUNTING HEIGHT CHOICES TO ARCHITECT FOR FINAL
DECISIONS.
G. COORDINATE ENGINEERING DRAWINGS WITH ARCHITECTURAL DRAWINGS
AND FIELD CONDITIONS, AND REPORT DISCREPANCIES IMMEDIATELY TO
ARCHITECT.
H. CONFLICTS BETWEEN SPECIFICATIONS AND DRAWINGS SHALL BE
COMMUNICATED TO THE ARCHITECT FOR RESOLUTION PRIOR TO
COMMENCEMENT OF THE WORK.
I. SUPPLY, COORDINATE, AND INSTALL ACCESS DOORS, PANELS AND HATCHES IN
CEILINGS, WALLS, AND FLOORS; AND NOTIFY ARCHITECT OF ANY CONFLICTS
WITH FEATURES SHOWN ON DRAWINGS.
J. PROVIDE WATER ROUGH-IN AND ELECTRICAL CONNECTIONS FOR OWNER-
PROVIDED EQUIPMENT IN COMPLIANCE WITH MEP DRAWINGS.
K. PROVIDE SLIP CHANNELS AT ALL LOCATIONS WHERE WALLS EXTEND TO A
STRUCTURAL MEMBER ABOVE.
L. DOORS ARE TO BE INSTALLED 4" FROM CORNER TO EDGE OF FRAME TYPICAL.
GENERAL PLAN NOTES
MATERIALS LEGEND
EARTH
NOTE: PATTERNS SHOWN REPRESENT CUT MATERIALS IN PLAN OR SECTION, UNLESS NOTED OTHERWISE BELOW.
GRANULAR FILL
SAND, GROUT
AS NOTED
CAST-IN-PLACE
CONCRETE
PRECAST CONCRETE,
CAST STONE
STONE: LIMESTONE, GRANITE,
MARBLE OR AS NOTED
TERRA COTTA, STRUCTURAL
CLAY TILE
CONCRETE MASONRY UNIT
BRICK MASONRY
METAL: TYPE AS NOTED
METAL: ROLLED SHAPES GLASS FIBER REINFORCED
CONCRETE SIDING OR TRIM
SHEATHING: GYPSUM, OR AS
NOTED
AIR BARRIER SYSTEM
ACOUSTICAL CEILING TILE
TILE: CERAMIC, QUARRY, UNO
CARPET, CARPET TILE (DETAIL)
GRATING
RESINOUS FLOORING: TERRAZZO,
TROWEL-ON, UNO
GRATING
SHOWN IN PLAN
INSULATED GLASS:
(SMALL SCALE)
INSULATED GLASS:
(DETAIL)
MEMBRANE: WATERPROOF, ROOF,
DAMPPROOFING
WOOD FRAMING / BLOCKING:
CONTINUOUS
FINISHED WOOD
SHOWN CUT AND ELEVATION
ENGINEERED WOOD: GLUE
LAMINATED
WOOD FLOOR, WOOD SHINGLES,
OR SIDING
WOOD SHIM
PARTICLEBOARD
PLYWOOD
EIFS
SPRAYED FIREPROOFING
SHOWN ON ROLLED SHAPE
BATT INSULATION: THERMAL OR
ACOUSTICAL, UNO
RIGID INSULATION: THERMAL,
ACOUSTICAL, OR SHAFTING
GYPSUM WALL BOARD
PLASTER ON METAL LATH
SYMBOLS LEGEND
(DETAIL VIEWS)
(ELEVATION VIEWS)A101
1 SIM
1i
1'-0"
Room
Name
XXXXX
DETAIL NUMBER
SHEET NUMBER
DETAIL CALLOUT
ELEVATION NUMBER
SHEET NUMBER
EXTERIOR ELEVATION TAG
SECTION NUMBER
SHEET NUMBER
SECTION MARKER
ATTRIBUTE
WALL TYPE
WALL TAG
CEILING TYPE
CEILING HEIGHT
CEILING TAG
7
2
DOOR ID NUMBER
REFER TO DOOR SCHEDULE SHEET
ROOM NAME
ROOM NUMBER
ROOM TAG
KEYED NOTE / PLAN NOTE
DEMOLITION NOTE
GLAZING TYPE
NEW CONSTRUCTION
EXISTING CONSTRUCTION
DEMOLISHED CONSTRUCTION
COL COLUMN GRID
CONTROL JOINT
SEALANT AND BACKER ROD
KIT OF PARTS NOTE
000000.00
TX
WINDOW TYPEX
GL-X
1/ A101
1
A101
ELEVATION NUMBER
SHEET NUMBER
INTERIOR ELEVATION TAG
SPEC SECTION REFERENCE
NOTE NUMBERA101
SIM1
TOILET ACCESSORY
FX FURNITURE/EQUIPMENT TAGXXX1 HR
W1A.S
Room
Name
XXXXX
Floor
Wall
Base
FINISH TAG
FLOOR FINISH
WALL FINISH
BASE FINISH
TOILET ACCESSORY MOUNTING HEIGHTS
1' - 0"3' - 6" 33" TO 36"17" - 19"8"
GRAB BARS
TOILET PAPER DISPENSER
SANITARY NAPKIN DISPOSAL WALL -MOUNTED OR FLOOR
MOUNTED WATER CLOSET
GRAB BARS
1' - 0"
3' - 0"34" MAX1' - 6"17" TO 19" 1' - 3"
PIPE INSULATION FOR
ADA COMPLIANCE 29" MIN CLEAR40" MAX CLEAR 3' - 0"1' - 6"42" MAX TO CONTROL3' - 5" 1' - 6"42" MAX TO CONTROLNOTE: REFER TO PROJECT MANUAL FOR COMPLETE TOILET ACCESSORY SPECIFICATIONS.
FIRE STOPPING SCHEDULE AND DETAILS
WALL CONSTRUCTION
FIRE SEAL MATERIAL AS
REQUIRED FOR FIRE
RATING FILLING ANNULAR
SPACE
PENETRATING ITEM
ABBREVIATIONS
CL.
CARPET
D.E.F.S.
CPT.
C.W.
C.M.
ACOUSTICAL
AMERICANS W/DISABILITIES ACT
AMERICANS W/DISABILITIES ACT
ACCESSIBILITY GUIDELINES
ARCHITECT/ENGINEER
C.I.P.
C.F.C.I.
B.O.W.
A.P.
A.V.
A/E
ADAAG
ADA
ACOUS.
FINISH(ED)
TBD TO BE DETERMINED
WELDED WIRE FABRIC
TEMPORARY
TEMPERED
TOP OF MASONRY
TOP OF DECK
TOP OF STEEL
VERIFY IN FIELD
VINYL COMPOSITION TILE
WIDE/WIDTH
WATER CLOSET
TECHNICAL
TOP OF CURB
TELEPHONE
TYPICAL
TOP OF WALL
TOP OF PAVEMENT
TONGUE AND GROOVE
UTILITY
UNIT VENTILATOR
VERTICAL
UNLESS NOTED OTHERWISE
WATER HEATER
WOOD
WITH
VESTIBULE
WEIGHT
ANGLE
MISCELLANEOUS
CENTER LINE
NUMBER
WITHOUT
#
W.W.F.
WD.
W.H.
WT.
W/O
FINISH OPENING
FLOOR
FLUORESCENTFLUOR.
F.O.
FLR.
W.C.
VIF
W
W
W/
VEST.
V.C.T.
UTIL.
U.N.0.
U.V.
V
VERT.
T&G
T.M.
T.S.
T.P.
TYP.
U
T.W.
T.D.
TMPRD.
TEMP.
T.C.
TECH.
TEL.
TACK BOARD
REFLECTED CEILING PLAN
REFERENCE
ROOF DRAIN
RADIUS
REFLECTED
RIGHT HAND
RESILIENT
ROOM
REINFORCED
ROUGH OPENING
SIMILAR
SHEET
SECTION
SOAP DISPENSER
SCHEDULE
SQUARE FEET
SQUARE
SPECIFICATION
SYMMETRICAL
SUSPEND(ED)
STRUCTURAL
STORAGE
STANDARD
STAINLESS STEEL
THICKNESS
CENTERLINE
E
FINISH SYSTEM
EXPOSED
ELECTRICAL CONTRACTOR
ELECTRICAL PANEL
EXTERIOR INSULATION
FAN COIL UNIT
AND EQUIPMENT
FURNISHINGS, FIXTURES
FINISH FLOOR ELEVATION
EACH
ELEVATION
EXPANSION JOINT
EQUAL
ENGINEER
ELEVATOR/ELEVATION
EXISTING
EXTERIOR
ELECTRIC WATER COOLER
EQUIPMENT
FABRICATE/FABRICATOR
FIRE EXTINGUISHER
FIRE HOSE CABINET
FLOOR DRAIN
FIRE EXTINGUISHER CABINET
ELECTRIC/ELECTRICAL
EXP.
F.F.&E.
FIN.
F.H.C.
F.F.E.
F.E.C.
F.E.
F
F.C.U.
FAB.
F.D.
EXT.
EQ.
EQUIP.
EXIST.
E.W.C.
E.P.
ENGR.
ELEV.
E.J.
EL.
ELEC.
E.I.F.S.
E.C.
EA.
SHT.
T.B.
SUSP.
SYM.
T
T.
SIM.
SQ.
S.S.
SPEC.
STRUCT.
STOR.
STD.
R.O.
S
S.D.
SECT.
SCHED.
S.F.
R.D.
REF.
REFL.
RESIL.
R.H.
RM
REINF.
COLD WATER
CONSTRUCTION MANAGER
FINISH SYSTEM
COORDINATE
CONCRETE
COLUMN
CEILING
CONCRETE MASONRY UNIT
CONTRACTOR
CONTINUOUS
CERAMIC TILE
CONSTRUCTION
DETAIL
DEPARTMENT
DRINKING FOUNTAIN
DOWN
DIMENSION
DISPENSER
DRY MARKER BOARD
DIAMETER
DRAWING
DOWNSPOUT
D
DN
DWG.
DS
D.M.B.
DIM.
DISP.
DEPT.
DET.
D.F.
DIA.
CONT.
C.T.
COOR.
CONTR.
C.M.U.
CONC.
CONST.
COL.
CLG.
R.C.P.
R
R
A
AUDIO/VISUAL
ACCESS PANEL
BOTTOM OF WALL
CONTRACTOR FURNISHED-
CONTRACTOR INSTALLED
CAST-IN-PLACE
ADJUSTABLE
AIR CONDITIONING
ACOUSTICAL CEILING TILE
ALTERNATE
ALUMINUM
ABOVE FINISHED FLOOR
ARCHITECT/ARCHITECTURAL
BOARD
BASEMENT
BUILDING
BITUMINOUS
CABINET
CORNER GUARD
CONTROL JOINT
B
C
C.G.
C.J.
CAB.
BLDG.
BSMT.
BITUM.
BD.
ALUM.
ARCH.
A.F.F.
ALT.
A.C.T.
ADJ.
A/C
ACOUSTICAL CEILING PANELACP
CLEAR(ANCE)CLR
CMP COMPOSITE METAL PANEL
FIRE-RESISTIVEF-R
TOP OFT/O
B/O BOTTOM OF
STEELSTL.
M.D.F.
MB.
M.C.
PROPERTY LINE
OWNER FURNISHED-
OWNER INSTALLED
OWNER FURNISHED-
CONTRACTOR INSTALLED
LENGTH
MARKER BOARD
LONG LEG OUT
LONG LEG VERTICAL
LONG LEG HORIZONTAL
MECH./ELECT./PLUMBING
MEDIUM DENSITY FIBERBOARD
MECHANICAL CONTRACTOR
METAL
MECHANICAL
MAXIMUM
MINIMUM
MISCELLANEOUS
MANHOLE
MANUFACTURER(ING)
MASONRY OPENING
NUMBER
NOT TO SCALE
NOT IN CONTRACT
NO APPLIED FINISH
ON CENTER
OVER ALL
OPENING
OPPOSITE HAND
OUTSIDE DIAMETER
PLASTER
PAIR
PARTICLE BOARD
PLYWOOD
PREFABRICATED
PLASTIC LAMINATE
QUARRY TILE
PAINTED
POUND
LAVATORY
LEFT HAND
Q
Q.T.
P. LAM
PLAS.
PT. BD.
PR.
PWD.
PREFAB.
PTD.
P.L.
O.F.O.I.
OPG.
O.H.
P
O.F.C.I.
O.C.
O.A.
O.D.
O
L
M.O.
MTL.
N
N.A.F.
N.T.S.
NO.
N.I.C.
M.E.P.
MECH.
MFR.
MISC.
MIN.
M.H.
L.L.V.
M
MAX.
L
L.L.O.
L.L.H.
LAV.
LB.
L.H.
OPPOSITEOPP.
GENERAL CONTRACTOR
HEIGHT
HOT WATER
FACE OF BRICK
FACE OF CONCRETE
FACE OF BLOCK
FIREPROOF
FACE OF STUD
FACE OF GYPSUM BD.
FACE OF FINISH
FIELD VERIFY
GENERAL
GAUGE
GLASS
FOOT/FEET
HARDWARE
HOSE BIBB
HEIGHT
HOLLOW METAL
HORIZONTAL
HEATING, VENTILATION & A.C.
GYPSUM WALL BOARD
GA.
HT.
H.W.
HVAC
HORIZ.
HB
HDWR.
H.M.
G.W.B./GWB
H
H.
G.C.
GEN.
GL.
F.O.G.
G
F.V.
F.O.S.
FPRF.
FT.
F.O.B.
F.O.BR.
F.O.C.
F.O.F.
INFORMATION
INCANDESCENT
INSIDE DIAMETER
INTERIOR
INSULATION
INCAN.
INFO.
INT.
INSUL.
I
I.D.
JOIST BEARING
JANITOR CLOSET
JANITOR
JOINT
J.C.
JST. BRG.
JT.
J
JAN.
FIRE
RATING
REF. DESIGN
No.
R-VALUE U-VALUE E1
BRICK ON METAL STUD.
0.52
COL
REFER TO WALL SECTIONS
3" TYP.
FIRE
RATING
REF. DESIGN
No.
R-VALUE U-VALUE E2
CMU ON METAL STUD.
0.52
COL
REFER TO WALL SECTIONS
3" TYP.
1' - 2"
AIR SPACE [04 00 00-D7]
FLUID-APPLIED MEMBRANE AIR
BARRIER SHOWN DASHED [07 27
26-A1]
SCREW -ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
INSULATION TYPE 2 -STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
SCREW -ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
FLUID-APPLIED MEMBRANE AIR
BARRIER SHOWN DASHED [07 27
26-A1]
5/8" GLASS-MAT GYPSUM
SHEATHING -TAPE ALL SEAMS [06
16 00-A2]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
EXTERIOR WALL TYPES SCHEDULE
INSULATION TYPE 2 -STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
FIRE
RATING
REF. DESIGN
No.
R-VALUE U-VALUE E3
FORMED METAL PANEL ON METAL STUD
0.52
NOTE: CONTRACTORS OPTION TO
SUBSTITUTE COMPOSITE NAIL BASE
INSULATED WALL SHEATHING IN LIEU OF
SEPARATE GYP SHEATHING, RIGID AND
PLYWOOD. REFER PROJECT MANUAL.
FORMED METAL WALL PANELS -
PREFINISHED [07 41 14-A1]
FLUID-APPLIED MEMBRANE AIR
BARRIER SHOWN DASHED [07 27
26-A1]
1' - 2"
INSULATION TYPE 4 -KRAFT FACED
FIBERGLASS BATT INSULATION, R19
MIN. [07 21 00-A4]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
INSULATION TYPE 4 -KRAFT FACED
FIBERGLASS BATT INSULATION, R19
MIN. [07 21 00-A4]
6" METAL STUD [05 41 00-A4]
6" METAL STUD [05 41 00-A4]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
INSULATION TYPE 4 -KRAFT FACED
FIBERGLASS BATT INSULATION, R19
MIN. [07 21 00-A4]
STANDARD BRICK -3/8" JOINT [04
20 00-A1]
6" 4 3/8" 3 5/8" 6" 3 1/8" 3 5/8"6" 6 5/8" 7/8"
1' - 1 1/2"
COL
REFER TO WALL SECTIONS
3 1/2" TYP.
NOTE: CONTRACTORS OPTION TO
SUBSTITUTE COMPOSITE NAIL BASE
INSULATED WALL SHEATHING IN LIEU OF
SEPARATE GYP SHEATHING, RIGID AND
PLYWOOD. REFER PROJECT MANUAL.
5/8" GLASS-MAT GYPSUM
SHEATHING -TAPE ALL SEAMS [06
16 00-A2]
5/8" GLASS-MAT GYPSUM
SHEATHING -TAPE ALL SEAMS [06
16 00-A2]
FIRE
RATING
REF. DESIGN
No.
R-VALUE U-VALUE E4
CMU ON CMU
0.52
7 5/8" 3 3/8" 3 5/8"
1' - 2 5/8"
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 -STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
8" X 8" X 16" GROUND FACE CMU
[04 22 00-D3]
FIRE
RATING
REF. DESIGN
No.
R-VALUE U-VALUE E5 1 HR U-425
1 HR RATED METAL STUD WALL
0.52
COL
REFER TO WALL SECTIONS
3" TYP.
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
INSULATION TYPE 4 -KRAFT FACED
FIBERGLASS BATT INSULATION, R19
MIN. [07 21 00-A4]
6"
NOTE: EXTERIOR FACADE OUTSIDE OF SHEATHING
VARIES, REFER TO EXTERIOR ELEVATIONS.
5/8" GLASS-MAT GYPSUM
SHEATHING -TAPE ALL SEAMS [06
16 00-A2]
DIRECTION DEPENDS ON SIDING
ORIENTATION -REFER TO ELEVATIONS
6" LIGHT GAUGE ZEE [05 40 00-D6]
INSULATION TYPE 2 -STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]DANDR ID GE DRE
W
WHI
TEHI T
AR-19400087
ARC TEC
STATE OF
No.
DNDI NAA AII
R E G I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
09/11/2020
A001
GENERAL NOTES,
SYMBOLS, LEGENDS AND
EXTERIOR WALLS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
SPECIALTY ACCESSORY SCHEDULE
TYPE ITEM MFR / MODEL REMARKS PROVIDED BY INSTALLED BY
T1 24"W X 36"T MIRROR BOBRICK B-290 2436 SATIN STAINLESS FINISH
T2 GRAB BARS (3 PIECE) BOBRICK B-6806 SERIES 36", 42" AND 18" VERTICAL
T3 TOILET PAPER DISPENSER - DOUBLE ROLL BOBRICK B-2892 19" MIN. A.F.F. TO C.L. - SURFACE MOUNTED
T4 SOAP DISPENSER BOBRICK B-2111 ADA COMPLIANT
T5 HAND DRYER BOBRICK B-3944 52-3/4" TO TOP - SURFACE MOUNTED
SCALE: 1" = 1'-0"1 WALL PENETRATION
# DESCRIPTION DATE
2 BID ADDEN. 005 03/24/2021
2
07/14/21
STANDARD SYSTEMS
SHAFTWALL SYSTEMS
NOTE: * = AT FRAMING EXCEEDING 12'-0" HEIGHT, PROVIDE BRACINGFRAMING1 5/8"
2-1/2"
2-1/2"
2-1/2"
3-5/8"
3-5/8"
3-5/8"
6"
6"
6"
2-1/2"
C-H STUDS
2-1/2"
C-H STUDS
2-1/2"
C-H STUDS
4"
C-H STUDS
4"
C-H STUDS
6" DBL
E STUDS
6" DBL
E STUDS
</= 6'-0"
> 6'-0" - </= 8'-0"
> 8'-0" - </= 10'-0"DEPTHAT MID HEIGHT LOCATION, BUT NOT TO EXCEED 12'-0" MAX.
SPAN
25--(0.0179")
25--(0.0179")
22--(0.0270")
20--(0.0329")
25--(0.0179")
22--(0.0270")
20--(0.0329")
25--(0.0179")
22--(0.0270")
20--(0.0329")
25--(0.0199")
22--(0.0294")
20--(0.0341")
25--(0.0199")
20--(0.0341")
25--(0.0199")
20--(0.0341")FRAMINGGAUGESTUD 16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
24"
24"
24"
24"
24"
24"
24"
2-4"X16GA. METAL CEE STUDS
2-6"X18GA. METAL CEE STUDS
2-6"X16GA. METAL CEE STUDSSPACINGALLOWABLEL/240
L/240
L/240
L/240
L/240
L/240
L/240
L/240
L/240
L/240
L/240
L/240
L/240
L/240
L/240
L/240
L/240
L/240
L/240
L/240
L/240
L/240
L/240
L/240
L/240
L/240
L/240
LINTEL SIZEDEFLECTIONFURRING2 HOUR1 LAYER8'-3"
7'-3"
11'-0"
9'-9"
12'-0"
10'-6"
13'-0"
11'-6"
14'-6"
12'-9"
16'-0"
14'-0"
17'-3"
15'-0"
20'-0"
15'-0"
25'-3"
22'-0"
26'-6"
23'-3"RATED12'-1"
14'-11"
15'-3"
16'-11"
18'-2"
26'-3"
28'-0"ONE SIDE*PARTITION1 HOUR1 LAYER9'-6"
8'-3"
12'-6"
10'-9"
13'-0"
11'-6"
14'-0"
12'-3"
16'-0"
13'-6"
17'-3"
15'-0"
18'-3"
16'-0"
20'-0"
15'-0"
26'-0"
22'-9"
27'-6"
24'-0"RATED11'-8"
13'-7"
14'-0"
15'-10"
17'-6"
25'-3"
28'-0"EACH SIDEPARTITION2 LAYERS10'-6"
8'-9"
13'-6"
11'-3"
14'-0"
12'-3"
14'-9"
13'-0"
16'-9"
13'-6"
18'-0"
15'-9"
19'-0"
16'-6"
20'-0"
15'-0"
23'-9"
20'-9"
25'-6"
22'-3"EACH SIDEINTERIOR WALL LIMITING HEIGHTS
LINTEL SCHEDULE U.N.O.
REFER FLOOR PLAN FOR
PARTITION TYPE
CUT GYPSUM WALLBOARD TO FIT
DECK FLUTES DEFLECTION TRACK
ATTACHED WITH ANCHORS
AT 2'-0" O.C.DO NOT ATTACH GYPSUM
WALLBOARD TO TOP TRACK
STRUCTURAL FLOOR OR ROOF
ASSEMBLY
FILL GAP WITH ACOUSTICAL
SEALANT
GYPSUM PARTITION AT STRUCTURE
REFER FLOOR PLAN FOR
PARTITION TYPE
HB PTA SERIES PARTITION TOP
ANCHOR OR OTHER APPROVED
LATERAL SUPPORT METHOD
STRUCTURAL FLOOR OR ROOF
ASSEMBLY
CMU PARTITION AT STRUCTURE
BOND BEAM - REF
STRUCTURAL
COMPRESSIBLE FILLER IN
JOINT AND FLOOR/ROOF1"FILL CAVITY WITH
ACOUSTICAL INSULATION
REFER FLOOR PLAN FOR
PARTITION TYPE
FIRECODE COMPOUND BOTH
SIDES. 1/2" @ 1 HR; 1" @ 2HR DEFLECTION TRACK
ATTACHED WITH ANCHORS
AT 2'-0" O.C.
DO NOT ATTACH GYPSUM
WALLBOARD TO TOP TRACK
STRUCTURAL FLOOR OR ROOF
ASSEMBLY
FIRE RATED GYPSUM PARTITION AT STRUCTURE
REFER FLOOR PLAN FOR
PARTITION TYPE
HB PTA SERIES PARTITION TOP
ANCHOR OR OTHER APPROVED
LATERAL SUPPORT METHOD
STRUCTURAL FLOOR OR ROOF
ASSEMBLY
FIRE RATED CMU PARTITION AT STRUCTURE
BOND BEAM - REF
STRUCTURAL1"FILL CAVITY WITH
THERMAFIBER SAFING
INSULATION
J-MOLD
FIRECODE COMPOUND BOTH
SIDES. 1/2" @ 1 HR; 1" @ 2HR
FILL CAVITY WITH THERMAFIBER
SAFING INSULATION
1/4" JOINT
#093 ZINC CONTROL
JOINT
GYPSUM WALLBOARD PER
PARTITION TYPE
GYPSUM PARTITION CONTROL JOINT
CMU CONTROL JOINT
BACKER ROD AND SEALANT
JOINT EA. SIDE OF WALL
FLANGED NEOPRENE
CONTROL JOINT CONT.
STOP HORIZ. BARS AT
EACH SIDE OF JOINT
VERTICAL REINFORCING
PER STRUCTURAL
SASH BLOCK CMU
3/8"
ADDITIONAL STUD AS
REQ'D
1/4" JOINT
#093X ZINC CONTROL
JOINT - FIRE RATED
GYPSUM WALLBOARD PER
PARTITION TYPE
GYPSUM PARTITION CONTROL JOINT
FIRE-RATED
ADDITIONAL STUD AS
REQ'D
THERMAFIBER INSULATION
CMU CONTROL JOINT FIRE RATED
BACKER ROD AND SEALANT
JOINT EA. SIDE OF WALL
CERAMIC FIBER BLANKET WERE
REQUIRED FOR FIRE RATING
STOP HORIZ. BARS AT
EACH SIDE OF JOINT
VERTICAL REINFORCING
PER STRUCTURAL
SASH BLOCK CMU
1/2"
STRUCTURAL FLOOR OR ROOF
ASSEMBLY
WALL HEIGHT C = EXTEND TO BOTTOM OF CEILINGWALL HEIGHT A = EXTEND WALL TO 6" ABOVE CEILINGWALL HEIGHT S = EXTEND WALL TO BOTTOM OF STRUCTURAL DECKBRACE TO STRUCTURE AT
4'-0" O.C. AT PARTIAL HEIGHT
WALLS
METAL STUDS. PROVIDE WIDTH
PER WALL TYPE AND GAGE AS
REQUIRED FOR HEIGHT
5/8" GYPSUM WALLBOARD
TYP. BOTH SIDES (USE TYPE X
FOR RATED ASSEMBLIES)
SOUND ATTENUATION
INSULATION AS SPECIFIED PER
WALL TYPE
CONTINUOUS METAL
RUNNER TRACK
ACOUSTICAL SEALANT
AT ALL JOINTS 45.00°
ACOUSTICAL SEALANT
AT ALL JOINTS
DEFLECTION TRACK AT
STRUCTURE
TYPICAL WALL NOTES
CEILING WHERE OCCURS
FIRE RATING
(AS OCCURS)
HEIGHT ATTRIBUTE
S - CONSTRUCT TO STRUCTURE ABOVE
A - CONSTRUCT WALL TO 6" ABOVE CEILING
C - CONSTRUCT WALL TO CEILING
**IF NO ATTRIBUTE - CONSTRUCT
WALL TO STRUCTURE.
1 HR
W1A.S
LOW WALL HEIGHT
AS OCCURS
1 HR
W1A.S
4' - 0"
WALL TYPE - REFER
SCHEDULE ON A002
WALL TYPE SYMBOL
TYPICAL WALL NOTES
A. VERIFY ALL RATED WALLS WITH LIFE SAFETY COMPLIANCE PLAN.
B. ALL RATED WALL ASSEMBLY CONSTRUCTION SHALL BE SEALED WITH FIRE/SMOKE
RATED SEALANT @ ALL JOINTS AND PENETRATIONS. PROVIDE SMOKE DAMPERS AT
ALL DUCT PENETRATIONS THROUGH RATED WALLS.
C. ALL ACOUSTICAL WALL ASSEMBLY CONSTRUCTION SHALL BE SEALED WITH
ACOUSTICAL SEALANT AT ALL JOINTS AND PENETRATIONS. REFER TO TYPICAL
ACOUSTICAL DETAILS.
D. WATER RESISTANT GYPSUM WALLBOARD SHALL BE USED IN LIEU OF TYPE 'X'
GYPSUM WALLBOARD IN ALL LOCATIONS WHERE CERAMIC AND PORCELAIN
TILE FINISH IS USED; AS WELL AS ALL RESTROOMS, KITCHEN, MECHANICAL
ROOMS, AND JANITOR CLOSETS.
E. GAGE OF ALL INTERIOR METAL STUD FRAMING TO BE DESIGNED FOR 5 PSF
WIND LOADS, STUD HEIGHT AND ADDITIONAL LOADING SUCH AS MILLWORK
OR SUSPENDED ITEMS WITH DEFLECTION LIMITED TO L/240.
F. ALL WALL FRAMING THAT EXTENDS ABOVE FINISH CEILING TO BE BRACED TO
STRUCTURE ABOVE AT 4'-0" O.C. ALTERNATING DIRECTIONS AS LIMITING HEIGHTS
REQUIRE.
G. ALL WALL FRAMING NOTED TO EXTEND TO CEILING OR 6" ABOVE CEILING TO
BE BRACED TO STRUCTURE AT 4'-0" O.C. ALTERNATING DIRECTIONS.
H. REFER TO REFLECTED CEILING PLAN FOR CEILING MATERIALS AND HEIGHTS;
REFER ROOM FINISH SCHEDULE FOR APPLIED FINISHES AND SPECIAL
INSTRUCTION.
J. PROVIDE METAL TRIM OR ZIP-STRIPS AT THE EDGES OF ALL GYPSUM WALLBOARD
WHERE IT ABUTS ANOTHER MATERIAL AND WHERE EDGES ARE EXPOSED TO VIEW.
K. DIVIDE ALL GYPSUM WALLBOARD AREAS WITH CONTROL JOINTS NOT EXCEEDING
30 FEET IN EITHER DIRECTION OR AS SHOWN OTHERWISE. PROVIDE RATED
CONTROL JOINTS IN FIRE RATED PARTITIONS. COORDINATE LOCATION OF
CONTROL JOINTS WITH ARCHITECT PRIOR TO INSTALLATION.
L. PROVIDE HIGH-IMPACT GYPSUM WALLBOARD IN ALL CORRIDORS, STAIRCASES
AND OTHER SPACES AS NOTED ON PLANS.
M. PROVIDE HORIZONTAL JOINT REINFORCEMENT AT 16" O.C. AT MASONRY WALLS.
PROVIDE VERTICAL REINFORCEMENT PER STRUCTURAL DRAWINGS AND
SPECIFICATIONS.
FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No.M4A - - - - -
DESCRIPTION: 4" cmu in running bond pattern
with horizontal joint reinforcement at 16" o.c.
vertically.
Refer to structural for vertical reinforcement.3 5/8"5 5/8" 7 5/8" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No.M6A - - - - -
DESCRIPTION: 6" cmu in running bond pattern
with horizontal joint reinforcement at 16" o.c.
vertically.
Refer to structural for vertical reinforcement.
FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No.M6B 1 HR UL U906 - -
DESCRIPTION: 6" cmu in running bond pattern
with horizontal joint reinforcement at 16" o.c.
vertically.
Refer to structural for vertical reinforcement.
FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No.M8A - - - - -
DESCRIPTION: 8" cmu in running bond pattern
with horizontal joint reinforcement at 16" o.c.
vertically.
Refer to structural for vertical reinforcement.
FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No.M8B 1 HR UL U905 - -
DESCRIPTION: 8" cmu in running bond pattern
with horizontal joint reinforcement at 16" o.c.
vertically.
Refer to structural for vertical reinforcement.5 5/8" 7 5/8" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No.M6C 2 HR UL U906 - -
DESCRIPTION: 6" cmu in running bond pattern
with horizontal joint reinforcement at 16" o.c.
vertically.
Refer to structural for vertical reinforcement.5 5/8" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No.M8C 2 HR UL U905 - -
DESCRIPTION: 8" cmu in running bond pattern
with horizontal joint reinforcement at 16" o.c.
vertically.
Refer to structural for vertical reinforcement.7 5/8" 7 5/8" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No.M8D 3 HR UL U904 - -
DESCRIPTION: 8" cmu in running bond pattern
with horizontal joint reinforcement at 16" o.c.
vertically.
Refer to structural for vertical reinforcement.9 5/8" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No.M10A - - - - -
DESCRIPTION: 10" cmu in running bond pattern
with horizontal joint reinforcement at 16" o.c.
vertically.
Refer to structural for vertical reinforcement.11 5/8" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No.M12A - - - - -
DESCRIPTION: 12" cmu in running bond pattern
with horizontal joint reinforcement at 16" o.c.
vertically.
Refer to structural for vertical reinforcement.
FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No. S2A - - - - -
INTERIOR FURRED WALL:One layer 5/8" X
gypsum
board applied vertically to one of 1-5/8" steel
studs
16" o.c.2 1/4"FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No. S3A - - - - -
INTERIOR FURRED WALL: One layer 5/8" X
gypsum
board applied vertically to one of 2-1/2" steel
studs
16" o.c.3 1/8" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No. S4C - - - - -
INTERIOR WALL: One layer 5/8" X gypsum board
applied vertically to each side of 3-5/8" steel studs
16" o.c.4 7/8" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No.S4A - - - - -
INTERIOR FURRED WALL:One layer 5/8" X
gypsum
board applied vertically to one of 3-5/8" steel
studs
16" o.c.4 1/4" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No.S4E 1 HR UL U419 - -
INTERIOR WALL: One layer 5/8" X gypsum board
applied vertically to each side of 3-5/8" steel studs
16" o.c. Fill stud cavities with 3" fiberglass batt
insulation.4 7/8" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No.S4B - - - - -
INTERIOR FURRED WALL: One layer 5/8" X
gypsum
board applied vertically to one of 3-5/8" steel
studs
16" o.c. Fill stud cavities with 3" fiberglass batt
insulation.4 1/4" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No.S4D - - - - -
INTERIOR WALL: One layer 5/8" X gypsum board
applied vertically to each side of 3-5/8" steel studs
16" o.c. Fill stud cavities with 3" fiberglass batt
insulation.4 7/8" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No.S4F 2 HR UL U419 - -
INTERIOR WALL: Two layers of 1/2" X gypsum
board
applied vertically to each side of 3-5/8" steel studs
16" o.c. Fill stud cavities with 3" fiberglass batt
insulation.5 5/8" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No. S6C - - - - -
INTERIOR WALL: One layer 5/8" X gypsum board
applied vertically to each side of 6" steel studs
16" o.c.7 1/4" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No.S6A - - - - -
INTERIOR FURRED WALL:One layer 5/8" X
gypsum
board applied vertically to one of 6" steel studs
16" o.c.6 5/8"FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No. S6E 1 HR UL U419 - -
INTERIOR WALL: One layer 5/8" X gypsum board
applied vertically to each side of 6" steel studs
16" o.c. Fill stud cavities with 5-1/2" fiberglass batt
insulation.
FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No. S6B - - - - -
INTERIOR FURRED WALL: One layer 5/8" X
gypsum
board applied vertically to one of 6" steel studs
16" o.c. Fill stud cavities with 5-1/2" fiberglass batt
insulation.
FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No. S6D - - - - -
INTERIOR WALL: One layer 5/8" X gypsum board
applied vertically to each side of 6" steel studs
16" o.c. Fill stud cavities with 5-1/2" fiberglass batt
insulation.
FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No.S6F 2 HR UL U419 - -
INTERIOR WALL: Two layers of 1/2" X gypsum
board
applied vertically to each side of 6" steel studs
16" o.c. Fill stud cavities with 5-1/2" fiberglass batt
insulation.8" 6 5/8"7 1/4" 7 1/4" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No. W4A - - - - -
INTERIOR FURRED WALL:One layer 5/8" X
gypsum
board applied vertically to one side of 2x4" wood
studs
16" o.c.4 1/8"FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No. W4B - - - - -
INTERIOR WALL: One layer 5/8" X gypsum
board applied vertically to both sides of 2x4" wood
studs 16" o.c.4 3/4" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No.W4C - - - 33 RAL-TL11-086
INTERIOR WALL: One layer 5/8" X gypsum
board applied vertically to both sides of 2x4" wood
studs 16" o.c. Fill stud cavities with 3-1/2"
fiberglass
batt insulation.4 3/4" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No. W4D 1 HR UL U305 - -
INTERIOR WALL: One layer 5/8" X gypsum
board applied vertically to both sides of 2x4" wood
studs 16" o.c. Fill stud cavities with 3-1/2"
fiberglass batt
insulation.4 3/4" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No. W6A - - - - -
INTERIOR FURRED WALL:One layer 5/8" X
gypsum
board applied vertically to one side of 2x6" wood
studs
16" o.c.6 1/8" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No. W6B - - - - -
INTERIOR WALL: One layer 5/8" X gypsum
board applied vertically to both sides of 2x6" wood
studs 16" o.c.6 3/4" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No.W6C - - - 33 RAL-TL11-086
INTERIOR WALL: One layer 5/8" X gypsum
board applied vertically to both sides of 2x6" wood
studs 16" o.c. Fill stud cavities with 5-1/2"
fiberglass batt
insulation.6 3/4" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No. W6D 1 HR UL U305 - -
INTERIOR WALL: One layer 5/8" X gypsum
board applied vertically to both sides of 2x4" wood
studs 16" o.c. Fill stud cavities with 5-1/2"
fiberglass batt
insulation.6 3/4" FIRE
RATING
REF. DESIGN
No.
STC
RATING
TEST No.W6E 1 HR UL U311 - -
INTERIOR WALL: One layer 5/8" X gypsum
board applied vertically to both sides of 2x4" wood
studs 16" o.c. Fill stud cavities with 5-1/2"
fiberglass batt
insulation.7 1/4" DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A002
INTERIOR WALL TYPES AND
DETAILS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
SCALE: 1 1/2" = 1'-0"02 TYPICAL INTERIOR WALL DETAILS
SCALE: 1 1/2" = 1'-0"01 TYPICAL INTERIOR WALL SECTION
SCALE: 3/4" = 1'-0"
INTERIOR WALL TYPES LEGEND
# DESCRIPTION DATE
07/14/21
FIG. 404.2.4.1
MANEUVERING CLEARANCE AT SWINGING DOORS
(B) FRONT APPROACH, PUSH SIDE (C) HINGE APPROACH, PULL SIDE (D) HINGE APPROACH, PULL SIDE (E) HINGE APPROACH, PUSH SIDE (G) LATCH APPROACH, PUSH SIDE(F) LATCH APPROACH, PULL SIDE
(445) (305)(915) (1065)(610)
(1370)(1065)(1370)(1525)(1525)(1065)(1220)(1220)(610)
FIG. 404.2.4.2
MANEUVERING CLEARANCE AT SLIDING AND FOLDING DOORS
(A) FRONT APPROACH (B) POCKET OR HINGE APPROACH (C) STOP OR LATCH APPROACH
FIG. 404.2.6
TWO DOORS IN A SERIES
(A) (B)(1220)(1065)(1065)(610)
(1370)(1220) (1220)
(A) CIRCULAR (B) T-SHAPED
(A) FORWARD (B) PARALLEL
FIG. 304.3
SIZE OF WHEELCHAIR TURNING SPACE
FIG. 405.5
POSITION OF CLEAR FLOOR OR GROUND SPACE
(1525) (1525)
(305) (915) (305)
(760) (1220)(915)(1525)(760)(1220)(A) FORWARD APPROACH (B) PARALLEL APPROACH
FIG. 305.7
MANEUVERING CLEARANCE IN AN ALCOVE
(915)(1525)(1220)(760)(X > 610)(X > 380)(1420)(405-455)
(1525)(430-485)FIG. 604.5.2
REAR WALL GRAB BAR FOR WATER CLOSET
FIG. 604.7
DISPENSER LOCATION
(1065)(305)
(1370)(380)(38)(180-230)(1220)(305)(610)
(915)
SIDE (1420)FIG. 604.8.1.1
WHEELCHAIR ACCESSIBLE TOILET COMPARTMENTS
(B) FLOOR-MOUNTED WATER CLOSET(A) WALL-HUNG WATER CLOSET (1420) (1525)
24" min.
FIG. 604.8.3
TOILET COMPARTMENT DOORS
(100)(1065)FIG. 606.3
HEIGHT OF LAVATORIES AND SINKS (865)FIG. 602.5
DRINKING FOUNTAIN SPOUT LOCATION
(A) PARALLEL APPROACH (B) FORWARD APPROACH
(380)(125)
(90)
(2440) (1525)
(2440)
(6100)(1525)FIG. 503.3
PASSENGER LOADING ZONE ACCESS AISLE
(760)(760)(610)(305)24" min.(380)9"(230)(610)(230)(305) (610)
FIG. 607.5
back wall
seat
wall
control
wall
(915) (1220)(915)(915)(760) (1525)(760)(1220)(760)(915)
(445)(150)(150)(150)(150) (150)FIG. 608.3.2
GRAB BARS IN ROLL-IN-TYPE SHOWERS
(C) GRAB BARS IN ROLL-IN-TYPE SHOWERS (1220)FIG. 608.5
CONTROLS IN TRANSFER-TYPE
control
wall
control
wall
(380)
(A)
(685)
(B)
back
FIG. 608.6
LOCATION OF SHOWER SPRAY UNIT
FIG. 609.3
SPACING OF GRAB BARS
(38)(380)(380-405)(430-485)(430-485) FIG. 610.3.1
RECTANGULAR SHOWER
COMPARTMENT SEAT
FIG. 610.3.2
L-SHAPED SHOWER
COMPARTMENT SEAT(75)(380-405)(38)(560-585)
(380-405)(355-380) (64)(38)FIG. 702.3.3.1
LOCATION OF WALL-MOUNTED APPLIANCES
(A) WALL ALARM (B) WALL ALARM WITH
SMOKE DETECTOR
FLOOR OR GROUND (100-305)(2030-2440)FLOOR OR GROUND(2030-2440) (CEILING HEIGHT > 9140)CEILING CEILING
FIG. 702.3.3.2
LOCATION OF CEILING-MOUNTED APPLIANCES
FIG. 702.3.5.1
APPLIANCE SPACING IN CORRIDORS (15-30m) (4570) (4570)(15-30m) (15-30m)
FIG. 702.3.6.2
APPLIANCE LOCATION IN SLEEPING ROOMS
(A) ONE BED
(4880)
(B) TWO BEDS
FIG. 703.2.4.4
CHARACTER HEIGHT
LIBRARY
(16-51)FIG. 703.2.8
MOUNTING LOCATION AT DOORS (455)(455)
(A) PARALLEL APPROACH
(B) FORWARD APPROACH
FIG. 704.2.1
CLEAR FLOOR OR GROUND
SPACE FOR TELEPHONES
FIG. 705.3.1.1
TRUNCATED DOME SIZE
(60)
(A) VERTICAL RISER (B) CURVED NOSING
(C) BEVELED NOSING (D) ANGLED RISER
RADIUS 1/2" MAX. TYP.
30 max.
beveled
FIG. 504.5
STAIR NOSINGS FIG. 504.2
TREADS AND RISERS FOR
ACCESSIBLE STAIRWAYS(100-180)(A) STAIRS (865-965)(B) RAMPS(865-965)FIG. 505.7
HANDRAIL CROSS SECTION
FIG. 505.4
HANDRAIL HEIGHT
(38)
FIG. 505.5
HANDRAIL CLEARANCE
(A) CIRCULAR
4"-6 1/4" PERIMETER
(100-160)
FIG. 505.10.1
TOP AND BOTTOM HANDRAIL EXTENSIONS AT RAMPS
(305)
(305)
FIG. 505.10.2
TOP HANDRAIL EXTENSIONS AT STAIRS
(305) X = TREAD DEPTH
FIG. 505.10.2
BOTTOM HANDRAIL EXTENSIONS AT STAIRS
FIG. 306.3
KNEE CLEARANCE
(205)
(280)(685)(230)FIG. 306.2
TOE CLEARANCE
(430)(230)FIG. 403.5.1
CLEAR WIDTH AT TURN (1065)(1065) (X < 1220)(610) (610)(1220)(815)(915)(1525)(1525)
LANDING
AT LEAST AS WIDE AS RAMP RUN
LANDING
(A)
FIG. 405.7
RAMP LANDINGS (1525)LANDING
RAMP RUN RAMP RUN
RAMP
RUN
(B)
(815)
90
(A) HINGED DOOR
(815)
(B) SLIDING DOOR
(815)
(C) FOLDING DOOR
FIG. 404.2.3
CLEAR WIDTH OF DOORWAYS
FIG. 307.4
REDUCED VERTICAL CLEARANCE (685)(X < 2030)FIG. 407.2.2
ELEVATOR CALL BUTTONS
FIG. 407.2.3.2.1
HEIGHT OF ELEVATOR VISIBLE SIGNALS (890-1220)(1830)FIG. 406.12
ISLANDS
(A) CUT THROUGH AT ISLAND
(B) CURB RAMP AT ISLAND(1220)(1220)(305) (305)
(A) EXTENDED SURFACE
FIG. 405.9
RAMP EDGE PROTECTION
(B) CURB OR BARRIER (X < 100)(X < 100)FIG. 406.3
COUNTER SLOPE OF SURFACES ADJACENT TO CURB RAMPS
12
11
20
ADJOINING SURFACE
MAXIMUM SLOPE
CURB RAMP
MAXIMUM SLOPE (1220)(A) (B)(X < 1220)FIG. 406.4
SIDES OF CURB RAMPS
RETURNED CURB
(C)
PLANTING
AREA
PLANTING
AREA
(A) (1220)(B)
FIG. 406.11
DIGINAL CURB RAMPS
(A) FRONT APPROACH, PULL SIDE
FIG. 604.2/604.3.1
WATER CLOSET LOCATION/
SIZE CLEARANCE
FIG. 604.4/604.5.1
HEIGHT OF WATER CLOSET/
SIDE WALL GRAB BAR FOR WATER CLOSET
FIG. 502.2/502.3
VEHICLE PARKING SPACE/
PARKING SPACE ACCESS AISLE
(B) NON-CIRCULAR (C) NON-CIRCULAR
BUILDING BLOCKS
MAX.(6.4)2
FIG. 303.2
VERTICAL CHANGES IN LEVEL
FIG. 303.3
BEVELED CHANGES IN LEVEL
1
FIG. 302.3
OPENINGS IN FLOOR
OR GROUND SURFACES
PROTRUDING OBJECTS
FIG. 307.3
POST-MOUNTED PROTRUDING OBJECTS
(100)
MAX.
(305)
MAX.
(305)
(X > 305)
(X > 305)
FIG. 307.2
LIMITS OF PROTRUDING OBJECTS(380)(1220)FIG. 308.2.1
UNOBSTRUCTED FORWARD REACH
FIG. 308.2.2
OBSTRUCTED HIGH FORWARD REACH(1220)(510) (510-635)(1220)(1220)(255)
FIG. 308.3.1
UNOBSTRUCTED SIDE REACH
FIG. 308.3.2
OBSTRUCTED HIGH SIDE REACH
(610)
FIG. 607.4.1
GRAB BARS FOR BATHTUBS
WITH PERMANENT SEATS
(WITH FIG. 607.2 CLEARANCES)
FIG. 607.4.2
GRAB BARS FOR BATHTUBS
WITHOUT PERMANENT SEATS
(WITH FIG. 607.2 CLEARANCES)
FIG. 608.2.1/608.3.1 FIG. 608.2.2
STANDARD ROLL-IN-TYPE
SHOWER COMPARTMENT
FIG. 608.2.2
STANDARD ROLL-IN-TYPE
SHOWER COMPARTMENT
FIG. 403.5
CLEAR WIDTH OF AN ACCESSIBLE ROUTE
ACCESS AISLE SERVING VAN PARKING SPACESACCESS AISLE SERVING CAR
PARKING SPACES
LONG DIMENSION
PERPENDICULAR
TO DIRECTION OF TRAVEL
(A) STANDARD ROLL-IN-TYPE SHOWER (B) ROLL-IN-TYPE SHOWER WITH SEAT
(1525)
(1525)
LOCATION OF BATHTUB CONTROLS TRANSFER-TYPE SHOWER COMPARTMENT WITH GRAB BARS
FLARED SIDES 1:10 MAX. SLOPE FLARED SIDES 1:12 MAX. SLOPE
*36" (915)mm MIN.
WHEN
WALL SPACE PERMITS (1170)(280)
(57) (32-51)
(38)
(13)(4570) (4880)head endfoot end wall(64)
(915)
(150)(150)(150)
curved
(13)C L
wall(305)foot end wallback wall back wall
head endwallend wall
(150)
SHOWERS
DOORS AND DOORWAYS
60" MIN.18" MIN.48" MIN.36" MIN. 60" MIN.42" MIN.54" MIN.42" MIN.54" MIN.48" MIN.24" MIN.12" MIN.
24" MIN.42" MIN48" MIN. 48" MIN. 54" MIN.48" MIN.42"MIN.42" MIN.24" MIN.
CLEAR FLOOR SPACE
60" MIN. 60" MIN.60" MIN.48" MIN.48" MIN.30" MIN. 30" MIN.36" MIN.12" MIN. 36" MIN. 12" MIN.48" MIN.36" MIN. 60" MIN.30" MIN.X > 15"X > 24"PLUMBING ELEMENTS AND FACILITIES
16"-18"17"-19"42" min.12" max.
60" min.56" min.54" min.1 1/2" min.7"-9"12" min.36" min.
TRANSFER 56" min.60" min.56" min.60" min.
4" max.48" min.34" max.15" max.5" max.
3 1/2" max.
GENERAL SITE AND BUILDING ELEMENTS
96" MIN. 60" MIN.FULL LENGTH OFPARKING SPACE96" MIN.
20' MIN.60" MIN.length of tub 30" min.30" min.length of tub
15" max.12" max.12" min.24" min.9"24" max.12" max. 36" min. 36"48" min.
36" min.
60" min.30" min. 30" min.
36" min.
60" min.36"18"
6" max.6" max.6" max.6" max.6" max.6" max6" max.6" max.48" max.15" max.
27" max.15" min.1 1/2"
15"-16"17"-19"17"-19"2 1/2" max.3" max.15"-16"11#2" max.22"-23"
15"-16"14"-15"2 1/2" max.1 1/2" max.4"-12"80"-96"30' MAX.CEILING HEIGHT > 30'15' MAX. 50'-100' 50'-100' 15' MAX.50'-100' 15' MAX.16' MAX.
16' MAX.5/8"-2"18" MIN.18" 20" MAX.10" MAX.(255)(510).9"2.35"2.35"(60)(23) .2"(5)11#2" MAX.
1 1/2" MAX.
11" MIN.34"-38"34"-38"1 1/2" MIN."
1 1/4"-2"2 1/4" MAX. 12" MIN.
12" MIN.X12" MIN.
X27" MIN.9" MIN.8" MIN.
11" MIN.9" MIN.17" MIN.42" min. 42" min.48" min.X < 48"36" min.32" min.24" max.48" min. 24" max.
60" min. 60" min.60" min.32" min.
32" min.
32" min.27" MAX.X < 80"35"-48"72" min.36" min.48" min.12" min. 12" min.X < 4"X < 4"48" min.X < 48"48" min.15" min.48" max.1/4"1/4" - 1/2"(6.4-13)4" MAX.X > 80"X > 27"X > 27"80" MIN.27" MAX.X > 12"
X > 12"(X > 2030)(X > 685) (X >685)(685)12" 12"
REACH RANGES
15" MIN.48" MAX.48" MAX.20" MAX. 44" MAX.(1120)20" - 25"48" MAX.48" MAX.10" MAX.46" MAX.24" MAX.
ACCESSIBLE ROUTES
COMMUNICATION ELEMENTS
AND FEATURES 1/2" MAX.60" min.(2030)4" MIN.-7" MAX.__12" min.
6" max.
AREA TO BE MARKED
wall
PLANTING
AREA
PLANTING
AREA (1220)48" min.AREA TO BE MARKED AREA TO BE MARKED
CL
CL
CL
CL
CL
CL
2' - 9 31/32"DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A003
ADA DETAILS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
# DESCRIPTION DATE
07/14/21
UP
00 SF0 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10197 SF10 x 2024 SF5 x 549 SF10 x 5147 SF10 x 15147 SF10 x 15145 SF10 x 1573 SF10 x 7.573 SF10 x 7.573 SF10 x 7.572 SF10 x 7.536 SF5 x 7.524 SF5 x 549 SF10 x 549 SF10 x 599 SF10 x 1099 SF10 x 1049 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 5153 SF10 x 15 153 SF10 x 15151 SF10 x 1553 SF0 x 2549 SF10 x 549 SF10 x 599 SF10 x 1024 SF5 x 5147 SF10 x 1573 SF10 x 7.573 SF10 x 7.573 SF10 x 7.549 SF10 x 549 SF10 x 5100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10101099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1049 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 599 SF10 x 1099 SF10 x 10252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25153 SF10 x 15 153 SF10 x 15252 SF10 x 251510249 SF10 x 25253 SF10 x 25157 SF10 x 1598 SF10 x 1049 SF10 x 549 SF10 x 54191099 SF10 x 1049 SF10 x 524 SF5 x 549 SF10 x 5A
1
A.1 B B.1 C C.1 D
2
3
4
5
6
7
8
9
10
11
12
13
1414
15
16
17
OFFICE
101
ELEC.
106
STAIR
108 01A20101A20203
A201
SPRINKLER
107
ELEV.
109
20' - 0" 20' - 0" 20' - 0"
60' - 0"20' - 0"20' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 22' - 10" 27' - 10"
6' - 8" 8' - 7" 12' - 7"8' - 5" 9' - 10" 8' - 10" 9' - 3"160' - 0"A110
01
A110
03
02A20102A20201
A301
04
A301
03
A301
01
A302
02
A302
02
A301
03
A302
TELECOM
103
STORAGE
UNITS
100
CONC
P2 1 10' - 4"CORRIDOR
1109' - 11" 10' - 4"6' - 6"
10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"180' - 0"S1 S2 S3 S5S1S2EX108108 EX1107' - 7 5/8"
12' - 4 1/2" 8' - 2 1/4"
29' - 10 3/4" 64' - 0" 8' - 0" 60' - 0" 7' - 11 7/8" 4' - 0" 16' - 0 1/8" 4' - 0" 15' - 9" 4' - 0"52' - 6 5/8" 6' - 11 3/8" 4' - 0"4' - 0"15' - 9" 4' - 0" 15' - 11 7/8" 4' - 0" 36' - 0 1/4" 4' - 0" 96' - 3" 4' - 0" 60' - 8 1/4"50' - 4 3/4"
12' - 11 1/8"
10' - 4"
19' - 11 1/8"
7' - 10"
16' - 3 1/8"19' - 10 3/4"3
4
4
5 5
5
5
5
5
11' - 5"7' - 6" BREAKROOM
102
A130
01
WC
105JANITOR
104
03/ A60104/ A601
A130
03
A130
02
9"
9"
9"
EX107
EX106 EX101B 101105 104103102EX101A2' - 0"6' - 8" 10' - 0" 6' - 0"
9
10
9
11
3
3
3
12
14
5' - 0"7' - 0" 5' - 0" 5' - 0" 4' - 0"
1
4
4
4
A. REFER TO A001-A002 FOR GENERAL NOTES, WALL TYPES, SYMBOLS AND TYPICAL
CONSTRUCTION DETAILS.
B. PROVIDE BULLNOSE CMU AT ALL EXPOSED CMU CORNERS.
C. PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM WALLBOARD AT THE
APPARATUS BAY AND ALL ROOMS DIRECTLY OFF OF IT.
D. PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM WALLBOARD AT ALL WET
WALLS IN KITCHENS, AND ALL WALLS AND CEILINGS IN BATHROOMS AND
JANITOR CLOSETS.
E. PROVIDE HIGH-IMPACT GYPSUM WALLBOARD AT ALL CORRIDORS, STAIRCASES
AND THE LOBBY.
F. PLAN KEYNOTES APPLY TO SHEETS A101, A102 AND A110.
GENERAL PLAN NOTES
A A.1 B B.1 C C.1 D
32
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
STAIR
11110' - 0"10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 153' - 6"19' - 8 1/4" 9' - 11" 24' - 11 3/8"170' - 0"04
A201
A110
04
01
A301
02
A301
03
A302
10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"
STORAGE
UNITS
100
CONC
P2 1
S14' - 0" 15' - 9" 4' - 0" 7' - 1 1/2" 111' - 9" 7' - 1 1/2"4' - 0" 25' - 9" 4' - 0"
63' - 6"4' - 0" 15' - 9" 4' - 0" 8' - 0" 109' - 11 7/8" 7' - 9 1/8" 4' - 0"15' - 9 1/4"
04
A306
111 EX111 01
A307
3
3
3
3
12
VESTIBULE
112
5' - 0" 7' - 0" 5' - 0"4' - 0"EX112
112
1
4 4
DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAAAII
R EG I STERE
DNDI NAAI
HI TARC TECDANDRID GE DREW
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A101
FIRST FLOOR
CONSTRUCTION PLAN
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
SCALE: 1/8" = 1'-0" 01 FIRST FLOOR CONSTRUCTION PLAN -AREA A
PLAN KEYNOTES
2 LAUNDRY TUB - REFER TO PLUMBING DRAWINGS.
3 PREFINISHED METAL DOWNSPOUT. REFER TO CIVIL DRAWINGS FOR CONNECTION
TO STORM DRAINAGE DETAILS.
4 CONCRETE FILLED 6" DIA STEEL BOLLARD - REFER TO DETAIL XX/AXXX. REFER TO CIVIL
DRAWINGS FOR EXTERIOR BOLLARDS. COORDINATE WITH FOOTINGS.
5 ALUMINUM EXTERIOR STOREFRONT SYSTEM.
9 COMPUTER KIOSK, COORDINATE POWER/DATA CONNECTIONS WITH VENDOR AND
REFERENCE MEP DRAWINGS.
10 TYPICAL 80", 8 PANEL ELECTRIC GREEN FEATURE WALL PANEL SYSTEM, W/ TWO
MONITORS.
11 TYPICAL 10', 12 PANEL ELECTRIC GREEN FEATURE WALL PANEL SYSTEM, W/SIGNAGE
ONLY
12 LOCATION OF HVAC SUPPLY/RETURN DUCTWORK, APPROX. 48"X48" PENETRATION
IN FLOOR, ABOVE, COORDINATE WITH HVAC CONTRACTOR IN FIELD.
14 STORAGE UNIT PROVIDER TO SUPPLY WHITE UNIT PANEL TO COVER DRYWALL IN
AREAS NOT OBSTRUCTED BY BUILT UNITS, TYPICAL THIS AREA.
SCALE: 1/8" = 1'-0"02FIRST FLOOR CONSTRUCTION PLAN -AREA B
#DESCRIPTION DATE
1 BID ADDEN. 001 10/13/2020
07/14/21
DN
UP 102 SF10 x 10102 SF10 x 1099 SF10 x 10150 SF10 x 15100 SF10 x 10100 SF10 x 10100 SF10 x 10154 SF10 x 15102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10187 SF10 x 18.599 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF 10 x 109 SF x 1099 SF10 x 1099 SF10 x 1049 SF10 x 5134 SF10 x 13.5147 SF10 x 15145 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15148 SF10 x 15148 SF10 x 1549 SF10 x 549 SF10 x 549 SF10 x 59 SF x 10199 SF10 x 2049 SF10 x 549 SF10 x 525 SF5 x 599 SF10 x 1099 SF10 x 1099 SF10 x 10102 SF10 x 10102 SF10 x 10149 SF10 x 15149 SF10 x 15134 SF10 x 13.5149 SF10 x 1549 SF10 x 599 SF10 x 1099 SF0 x 20104 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 1050 SF10 x 599 SF10 x 109199 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10199 SF10 x 20199 SF10 x 201199 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10199 SF10 x 20199 SF10 x 20199 SF10 x 20199 SF10 x 20199 SF10 x 20199 SF10 x 20199 SF10 x 20199 SF10 x 2099 SF10 x 1099 SF10 x 10199 SF10 x 2049 SF10 x 591199 SF10 x 2049 SF10 x 5156 SF10 x 1524 SF5 x 599 SF10 x 1049 SF10 x 549 SF10 x 524 SF5 x 5A
1
A.1 B B.1 C C.1 D
2
3
4
5
6
7
8
9
10
11
12
13
14
15
ELEV.
202 01A20101A20203
A201
02A20102A20201
A301
04
A301
03
A301
01
A302
02
A302
S1 S1
S1S1S2
S2S2A120
02STAIR
201
12' - 8 1/4" 7' - 9 7/8"18' - 7 3/4"4 1/4" 67' - 5 3/4"
4' - 4"4' - 4"8' - 4"4' - 0" 15' - 9" 2' - 0"2' - 0"15' - 11 7/8" 4' - 0" 201STORAGE
UNITS
200
CONC
P2 1
ENCLOSED SOFFIT
SPACE
12
A. REFER TO A001-A002 FOR GENERAL NOTES, WALL TYPES, SYMBOLS AND TYPICAL
CONSTRUCTION DETAILS.
B. PROVIDE BULLNOSE CMU AT ALL EXPOSED CMU CORNERS.
C. PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM WALLBOARD AT THE
APPARATUS BAY AND ALL ROOMS DIRECTLY OFF OF IT.
D. PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM WALLBOARD AT ALL WET
WALLS IN KITCHENS, AND ALL WALLS AND CEILINGS IN BATHROOMS AND
JANITOR CLOSETS.
E. PROVIDE HIGH-IMPACT GYPSUM WALLBOARD AT ALL CORRIDORS, STAIRCASES
AND THE LOBBY.
F. PLAN KEYNOTES APPLY TO SHEETS A101, A102 AND A110.
GENERAL PLAN NOTES
A A.1 B B.1 C C.1 D
32
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
04
A201
02
A301
03
A302
S1S1A121
02STAIR
203
4' - 0" 25' - 9" 4' - 0" 25' - 9" 4' - 0"
04
A306
203 01
A307
STORAGE
UNITS
200
CONC
P2 1
ENCLOSED SOFFIT
SPACE
12
1 DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DNDI NAA AII
R E G I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A102
SECOND FLOOR
CONSTRUCTION PLAN
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
SCALE: 1/8" = 1'-0" 01 SECOND FLOOR CONSTRUCTION PLAN -AREA A
PLAN KEYNOTES
2 LAUNDRY TUB - REFER TO PLUMBING DRAWINGS.
3 PREFINISHED METAL DOWNSPOUT. REFER TO CIVIL DRAWINGS FOR CONNECTION
TO STORM DRAINAGE DETAILS.
4 CONCRETE FILLED 6" DIA STEEL BOLLARD - REFER TO DETAIL XX/AXXX. REFER TO CIVIL
DRAWINGS FOR EXTERIOR BOLLARDS. COORDINATE WITH FOOTINGS.
5 ALUMINUM EXTERIOR STOREFRONT SYSTEM.
9 COMPUTER KIOSK, COORDINATE POWER/DATA CONNECTIONS WITH VENDOR AND
REFERENCE MEP DRAWINGS.
10 TYPICAL 80", 8 PANEL ELECTRIC GREEN FEATURE WALL PANEL SYSTEM, W/ TWO
MONITORS.
11 TYPICAL 10', 12 PANEL ELECTRIC GREEN FEATURE WALL PANEL SYSTEM, W/SIGNAGE
ONLY
12 LOCATION OF HVAC SUPPLY/RETURN DUCTWORK, APPROX. 48"X48" PENETRATION
IN FLOOR, ABOVE, COORDINATE WITH HVAC CONTRACTOR IN FIELD.
14 STORAGE UNIT PROVIDER TO SUPPLY WHITE UNIT PANEL TO COVER DRYWALL IN
AREAS NOT OBSTRUCTED BY BUILT UNITS, TYPICAL THIS AREA.
SCALE: 1/8" = 1'-0"02SECOND FLOOR CONSTRUCTION PLAN -AREA B
#DESCRIPTION DATE
1 BID ADDEN. 001 10/13/2020
07/14/21
DN 102 SF10 x 10102 SF 10 x 1099 SF10 x 10150 SF7.5 x 12.599 SF10 x 1099 SF10 x 1099 SF10 x 10153 SF7.5 x 12.549 SF10 x 59 SF0 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10103 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF 10 x 109 SF0 x 1099 SF10 x 1099 SF10 x 10148 SF10 x 13.5139 SF10 x 13.5134 SF10 x 13.5141 SF10 x 13.5147 SF10 x 15145 SF10 x 1549 SF0 x 15149 SF10 x 1549 SF10 x 549 SF 10 x 549 SF10 x 598 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1049 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 5149 SF10 x 1549 SF0 x 1599 SF10 x 1020 SF5 x 320 SF5 x 3102 SF10 x 10102 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10102 SF10 x 1099 SF10 x 1049 SF10 x 549 SF10 x 549 SF10 x 599 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 109199 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 1511149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 1599 SF10 x 1099 SF10 x 1099 SF10 x 10149 SF10 x 15150 SF10 x 1591 SF10 x 10149 SF10 x 15154 SF10 x 15149 SF10 x 15149 SF10 x 1549 SF10 x 549 SF10 x 549 SF10 x 511149 SF10 x 1591A
1
A.1 B B.1 C C.1 D
2
3
4
5
6
7
8
9
10
11
12
13
14
15
ELEV.
302
03
A201
01
A301
04
A301
03
A301
01
A302
02
A302
S1 S1
S1S1S2 S2 S2
S2 S2 S2 S2 A120
03STAIR
301
21' - 0 3/4" 9' - 5 3/8"16' - 0"4' - 0" 16' - 0" 4' - 0" 301 STORAGE
UNITS
300
CONC
P2 1
12
A A.1 B B.1 C C.1 D
32
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
01
A301
02
A302
02
A301
03
A302
S4 S2S2S1S1S4
A121
03
STAIR
303
04
A306
01
A307303 STORAGE
UNITS
300
CONC
P2 1
12
A. REFER TO A001-A002 FOR GENERAL NOTES, WALL TYPES, SYMBOLS AND TYPICAL
CONSTRUCTION DETAILS.
B. PROVIDE BULLNOSE CMU AT ALL EXPOSED CMU CORNERS.
C. PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM WALLBOARD AT THE
APPARATUS BAY AND ALL ROOMS DIRECTLY OFF OF IT.
D. PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM WALLBOARD AT ALL WET
WALLS IN KITCHENS, AND ALL WALLS AND CEILINGS IN BATHROOMS AND
JANITOR CLOSETS.
E. PROVIDE HIGH-IMPACT GYPSUM WALLBOARD AT ALL CORRIDORS, STAIRCASES
AND THE LOBBY.
F. PLAN KEYNOTES APPLY TO SHEETS A101, A102 AND A110.
GENERAL PLAN NOTES
DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A103
THIRD FLOOR
CONSTRUCTION PLAN
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
SCALE: 1/8" = 1'-0" 01 THIRD FLOOR CONSTRUCTION PLAN -AREA A
SCALE: 1/8" = 1'-0" 02 THIRD FLOOR CONSTRUCTION PLAN -AREA B
PLAN KEYNOTES
2 LAUNDRY TUB - REFER TO PLUMBING DRAWINGS.
3 PREFINISHED METAL DOWNSPOUT. REFER TO CIVIL DRAWINGS FOR CONNECTION
TO STORM DRAINAGE DETAILS.
4 CONCRETE FILLED 6" DIA STEEL BOLLARD - REFER TO DETAIL XX/AXXX. REFER TO CIVIL
DRAWINGS FOR EXTERIOR BOLLARDS. COORDINATE WITH FOOTINGS.
5 ALUMINUM EXTERIOR STOREFRONT SYSTEM.
9 COMPUTER KIOSK, COORDINATE POWER/DATA CONNECTIONS WITH VENDOR AND
REFERENCE MEP DRAWINGS.
10 TYPICAL 80", 8 PANEL ELECTRIC GREEN FEATURE WALL PANEL SYSTEM, W/ TWO
MONITORS.
11 TYPICAL 10', 12 PANEL ELECTRIC GREEN FEATURE WALL PANEL SYSTEM, W/SIGNAGE
ONLY
12 LOCATION OF HVAC SUPPLY/RETURN DUCTWORK, APPROX. 48"X48" PENETRATION
IN FLOOR, ABOVE, COORDINATE WITH HVAC CONTRACTOR IN FIELD.
13 6" BLOCK BUILT UP 2' ABOVE FINISH FLOOR WITH SOLID TOP BLOCK. 6" METAL STUDS
ABOVE BLOCK.
14 STORAGE UNIT PROVIDER TO SUPPLY WHITE UNIT PANEL TO COVER DRYWALL IN
AREAS NOT OBSTRUCTED BY BUILT UNITS, TYPICAL THIS AREA.
#DESCRIPTION DATE
07/14/21
RT:
RL: XX'
X ROOF TYPE
APPROXIMATE ROOF HEIGHT
60 MIL MECHANICALLY FASTENED TPO MEMBRANE ROOFING SYSTEM OVER
POLYISOCYANURATE INSULATION (R30 MIN.) OVER METAL DECK.
RT1:
TAPERED INSULATION CRICKETS
1/2":12" MIN. SLOPE.
A. PROVIDE MANUFACTURERS STANDARD DETAILS WHERE MECHANICAL
EQUIPMENT OCCURS, COORDINATE WITH ARCHITECTURE AND MEP.
B. PROVIDE MANUFACTURERS STANDARD DETAILS AT ROOF BASE FLASHING,
RIDGES, TAPERED INSULATION CRICKETS, ROOF EDGES, ETC.
C. NOT ALL MEP EQUIPMENT AND PENETRATIONS ARE SHOWN. SEE MECHANICAL,
ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL ROOF
PENETRATION REQUIREMENTS.
D. COORDINATE ALL ROOFTOP OPENINGS WITH STRUCTURAL AND MECHANICAL
DRAWINGS.
ROOFTOP WALKWAY PAD BY
ROOFING MEMBRANE MFR.
GENERAL ROOF NOTES
ROOF TYPES LEGEND
A
1
A.1 B B.1 C C.1 D
2
3
4
5
6
7
8
9
10
11
12
13
14
15 01A20101A20203
A201
02A20102A20201
A301
04
A301
03
A301
01
A302
02
A302
1/4" / 1'-0"
1/4" / 1'-0"
1
1
1
3
3
2
2
4
5
3
1/4" / 1'-0"
1/4" / 1'-0"
3
1
2
RT:
RL:VARIES
RT1
A A.1 B B.1 C C.1 D
32
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
04
A201
01
A301
01
A302
02
A302
02
A301
03
A302
04
A306
1/4" / 1'-0"
1/4" / 1'-0"
01
A307
3
2
2
3
1/4" / 1'-0"
1/4" / 1'-0"
1
1
1
2
1
RT:
RL:VARIES
RT1
DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DNDI NAAAII
R EG I STERE
DNDI NAAI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
AUTHOR
CHECKER
07/02/2015
A104
ROOF PLAN
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff -Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
ROOF PLAN KEYNOTES
1 PRE-MANUFACURED METAL COPING
2 EIFS CONTROL JOINT, TYPICAL.
3 ADDITIONAL 1/4" PER FOOT TAPERED INSULATION SHOWN CROSSHATCHED.
4 SAFETY LINE CABLE SYSTEM WITH POST ANCHORS - COORDINATE ANCHORING WITH
STRUCTURAL DWGS.
5 ROOF HATCH AND ACCESS LADDER
6
SCALE: 1/8" = 1'-0" 01 ROOF PLAN -AREA A
SCALE: 1/8" = 1'-0" 02 ROOF PLAN -AREA B
#DESCRIPTION DATE
07/14/21
154SF153SFUP
A. REFER TO A001-A002 FOR GENERAL NOTES, WALL TYPES, SYMBOLS AND TYPICAL
CONSTRUCTION DETAILS.
B. PROVIDE BULLNOSE CMU AT ALL EXPOSED CMU CORNERS.
C. PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM WALLBOARD AT THE
APPARATUS BAY AND ALL ROOMS DIRECTLY OFF OF IT.
D. PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM WALLBOARD AT ALL WET
WALLS IN KITCHENS, AND ALL WALLS AND CEILINGS IN BATHROOMS AND
JANITOR CLOSETS.
E. PROVIDE HIGH-IMPACT GYPSUM WALLBOARD AT ALL CORRIDORS, STAIRCASES
AND THE LOBBY.
F. PLAN KEYNOTES APPLY TO SHEETS A101, A102 AND A110.
GENERAL PLAN NOTES
A
1
A.1 B B.1 C C.1
2
3
S1 S2 S3
02/ A601
01/ A601OFFICE
101
WF1
PT1
WB1
TELECOM
103
C1
PT1
WB1S1
S5S6C
S6C
S6C
S6C
S6C
S6C7' - 8 3/4"9' - 3 5/8" 9' - 11 7/8"22' - 5 5/8" 27' - 6 5/8"
15' - 11 1/2" 5' - 10 7/8"
12' - 6 5/8"
6' - 0 3/4"4' - 0"15' - 9" 03/ A6011' - 5"04/ A601
4' - 0" 15' - 9" 4' - 0" 16' - 0" 4' - 0" 8' - 9 5/8"EX101AEX101B 101105104103 10243' - 0 7/8"12' - 3 3/4"
BREAKROOM
102
WF1
PT1
WB1 JANITOR
104
C1
PT1
WB1
WC
105
C1
PT1
WB1
12' - 4 1/4"40' - 11 5/8"OFFICE
101
WF1
PT1
WB1
TELECOM
103
C1
PT1
WB1
BREAKROOM
102
WF1
PT1
WB1
JANITOR
104
C1
PT1
WB1
WC
105
C1
PT1
WB1
B.1 C C.1
9
10
11
12
A120
01
ELEC.
106
C1
SPRINKLER
107
C1
STAIR
108
C1
PT2
ELEV.
109
C1
CORRIDOR
110 EX1081082 HR
M8C
2 HR
M8C
ES6
2 HR
M8C
2 HR
M8C
M8A
M8A
M8A
ES6
ES6
6' - 11 3/8"
11' - 5" 7' - 9 7/8"
19' - 10 1/2"9' - 4 3/8"8' - 1 7/8" 9' - 2 7/8" 12' - 11 1/8"
EX106
B B.1 C C.1 D
32
28
29
30
31
A121
01
LOADING
BAY
112
C1
PT2
STAIR
111
C1
PT2
112B
EX112
2 HR
M8C
2 HR
M8C
M8A
ES6
M8A
112A 111DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DNDI NAA AII
R E G I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A110
ENLARGED PLANS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
ENLARGED PLAN KEYNOTES
1 CLOUMN - REFER TO STRUCTURAL
2 CLEANING DRAIN
3 BREAK ROOM SINK
4 BREAK ROOM COUNTER
5 OVER COUNTER CABNETS
SCALE: 1/4" = 1'-0"01 ENLARGED PLAN -OFFICE
SCALE: 1/4" = 1'-0"02REFLECTED CEILING PLAN -OFFICE
SCALE: 1/4" = 1'-0"03 ENLARGED PLAN -CIRCULATION
SCALE: 1/4" = 1'-0"04ENLARGED PLAN -LOADING BAY
#DESCRIPTION DATE
1
1
2
3 45
07/14/21
UPUP
DNDN
B.1 C C.1
11 9' - 2 7/8"3" 4' - 0" 8 7/8" 4' - 0"4' - 3" 10' - 1"
2 HR
M8C
2 HR
M8C
2 HR
M8C EX108108 STAIR
108
C
11
B.1 C.1
8 5/8"
PROVIDE SAFETY GATE AT THE
BOTTOM OF STAIR RUN, TYPICAL.
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
B.1C C.1
ROOF - AREA A
134' - 8"
11 EQUAL TREADS = 10' - 1" 4' - 2"12 EQUAL RISERS = 6' - 8" 12 EQUAL RISERS = 6' - 8" 12 EQUAL RISERS = 5' - 4" 12 EQUAL RISERS = 5' - 4"4' - 4"11 EQUAL TREADS = 10' - 1"
11 EQUAL TREADS = 10' - 1" 4' - 2"
4' - 4"11 EQUAL TREADS = 10' - 1"
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
11 12
ROOF - AREA A
134' - 8"
B.1 C C.1
11 9' - 2 7/8"3" 4' - 0" 8 7/8" 4' - 0" 3"4' - 3" 10' - 1"
2 HR
M8C
2 HR
M8C 201STAIR
201
C
11
B.1 C.1
B.1 C C.1
11 9' - 2 7/8"3"4' - 0" 8 7/8" 4' - 0" 3" 4' - 3" 10' - 1" 5' - 5 1/2"
19' - 9 1/2"
2 HR
M8C
2 HR
M8C
2 HR
M8C
301STAIR
301
C
11
B.1 C.1
DANDR ID GE DRE
W
WHI
TEHI T
AR-19400087
ARC TEC
STATE OF
No.
DNDI NAA AII
R E G I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A120
STAIR PLANS AND
SECTIONS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
PLAN KEYNOTES
2 LAUNDRY TUB - REFER TO PLUMBING DRAWINGS.
3 PREFINISHED METAL DOWNSPOUT. REFER TO CIVIL DRAWINGS FOR CONNECTION
TO STORM DRAINAGE DETAILS.
4 CONCRETE FILLED 6" DIA STEEL BOLLARD - REFER TO DETAIL XX/AXXX. REFER TO CIVIL
DRAWINGS FOR EXTERIOR BOLLARDS. COORDINATE WITH FOOTINGS.
5 ALUMINUM EXTERIOR STOREFRONT SYSTEM.
9 COMPUTER KIOSK, COORDINATE POWER/DATA CONNECTIONS WITH VENDOR AND
REFERENCE MEP DRAWINGS.
10 TYPICAL 80", 8 PANEL ELECTRIC GREEN FEATURE WALL PANEL SYSTEM, W/ TWO
MONITORS.
11 TYPICAL 10', 12 PANEL ELECTRIC GREEN FEATURE WALL PANEL SYSTEM, W/SIGNAGE
ONLY
12 LOCATION OF HVAC SUPPLY/RETURN DUCTWORK, APPROX. 48"X48" PENETRATION
IN FLOOR, ABOVE, COORDINATE WITH HVAC CONTRACTOR IN FIELD.
13 6" BLOCK BUILT UP 2' ABOVE FINISH FLOOR WITH SOLID TOP BLOCK. 6" METAL STUDS
ABOVE BLOCK.
14 STORAGE UNIT PROVIDER TO SUPPLY WHITE UNIT PANEL TO COVER DRYWALL IN
AREAS NOT OBSTRUCTED BY BUILT UNITS, TYPICAL THIS AREA.
KIT OF PARTS
03 30 00-A1 CIP CONCRETE SLAB ON GRADE - REFER TO STRUCTURAL DRAWINGS
SCALE: 1/4" = 1'-0"01 STAIR PLAN
SCALE: 1/2" = 1'-0"04STAIR SECTION
SCALE: 1/2" = 1'-0" 05STAIR SECTION
SCALE: 1/4" = 1'-0" 02 STAIR PLAN
SCALE: 1/4" = 1'-0" 03STAIR PLAN
#DESCRIPTION DATE
07/14/21
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
B B.1
ROOF - AREA A
134' - 8"12 EQUAL RISERS = 5' - 4"12 EQUAL RISERS = 6' - 8" CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
3231
ROOF - AREA A
134' - 8"
B B.1
32
31
2 HR
M8C
2 HR
M8C
2 HR
M8C
?ES6
STAIR
111
19' - 4 3/8"
19' - 4 3/8"9' - 10 5/8"B
31
32
B.1
8"
PROVIDE SAFETY GATE AT THE
BOTTOM OF STAIR RUN, TYPICAL.
B B.1
32
31
2 HR
M8C
2 HR
M8C
2 HR
M8C
ES6 203STAIR
203
B
31
32
B.1
B B.1
32
31
S4 3032 HR
M8C
2 HR
M8C
2 HR
M8C
STAIR
303
B
31
32
B.1 DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DNDI NAAAII
R E G I STERE
DNDI NAAI
HI TARC TECDANDRID GE DREW
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A121
STAIR PLANS AND
SECTIONS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
SCALE: 1/2" = 1'-0"04STAIR SECTION
SCALE: 1/2" = 1'-0"05STAIR SECTION
SCALE: 1/4" = 1'-0"01 STAIR PLAN
SCALE: 1/4" = 1'-0" 02STAIR PLAN
SCALE: 1/4" = 1'-0" 03 STAIR PLAN
#DESCRIPTION DATE
07/14/21
1 1/2"
WALL -MOUNTED HANDRAIL WITH
SUPPORT BRACKET [05 51 13-A9]
ANCHOR PER MANUFACTURER
REQUIREMENTS
GROUT CORES SOLID AT ANCHORS
WALL TYPE PER PLAN
1 1/2" MIN
WALL -MOUNTED HANDRAIL WITH
SUPPORT BRACKET [05 51 13-A9]
ANCHOR PER MANUFACTURER
REQUIREMENTS
BLOCKING BETWEEN STUDS
FOR ATTACHMENT
WALL TYPE PER PLAN 3' - 0"3' - 6"4" MAXMAX
4" OC1 1/2" O.D. STEEL PIPE RAILS - PAINTED
5/8" DIA. STEEL BAR PICKETS -
PAINTED
STEEL CHANNEL STRINGER
4' - 0" MAX
1-1/2" DIA. STEEL HAND RAIL -
PAINTED
5"2 1/2" 4" MAX.
METAL DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A2]
STEEL TUBE RAILING [05 51 13-A7]2".STEEL LANDING STRUCTURE [05 51
13-A2]
STEEL CHANNEL STRINGER [05 51
13-A5]
CLOSURE PLATE AT
STRINGER END
3" +/- 1/2"
STEEL CHANNEL STRINGER [05 51
13-A5]METAL DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A2]
STEEL FILLER PLATE
REFER TO PLAN FOR WALL TYPE
SEALANT JOINT 4" MAX 2 1/2" 3"
STEEL TUBE RAILING [05 51 13 -A7]
METAL DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A2]
CLIP ANGLE [05 51 13-A6]
STEEL CHANNEL STRINGER [05 51
13-A5]
CLOSURE PLATE AT
STRINGER END
3" +/- 1/2"
METAL DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A2]
STEEL FILLER PLATE
REFER TO PLAN FOR WALL TYPE
SEALANT JOINT
STEEL LANDING STRUCTURE [05 51
13-A2]2"STEEL TUBE RAILING [05 51 13-A7]
1X POPLAR WOOD TRIM
1x3 AT TOP AND 1x8 AT SIDE
1 1/2" O.D. STEEL PIPE RAILS - PAINTED
1/2" DIA. STEEL BAR PICKETS - PAINTED
1-1/2" DIA. STEEL HAND RAIL - PAINTED
2"4"3' - 6"REFER TO PLAN FOR WALL TYPE
ROPPE NOSING #4. COLOR TBD.
1/2" STEEL PLATE [05 12 00-A10]
3-5/8" METAL STUD [05 41 00-A2]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
+/- 1"
6" 5"2 1/2" 4" MAX.
STRUCTURAL STEEL BEAM [05 12
00-A1]
1/2" STEEL PLATE [05 12 00-A10]
METAL DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A2]
STEEL TUBE RAILING [05 51 13-A7]
STEEL CHANNEL STRINGER [05 51
13-A5]
EDGE OF SLAB
CLOSURE PLATE AT STRINGER
EOS
4 1/2" 6"2 1/2" 4" MAX.1/2" STEEL PLATE [05 12 00 -A10]
METAL DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A2]
STEEL TUBE RAILING [05 51 13-A7]
STEEL CHANNEL STRINGER [05 51
13-A5]6"S03
STRUCTURAL STEEL BEAM [05 12
00-A1]
1/2" STEEL PLATE [05 12 00-A10]2 1/2"4" MAX EOS
4 1/2" 6"
METAL DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A2]
STEEL TUBE RAILING [05 51 13-A7]
STEEL CHANNEL STRINGER [05 51
13-A5]
STEEL CHANNEL STRINGER [05 51
13-A5]METAL DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A2]
REFER TO PLAN FOR
WALL TYPE
SEALANT JOINT
STEEL TUBE RAILING [05 51 13-A7]
1/2"DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A122
STAIR DETAILS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
SCALE:
TYPICAL DETAIL
3" = 1'-0"04STAIR -HANDRAIL AT CMU WALL
KIT OF PARTS
SCALE:
TYPICAL DETAIL
3" = 1'-0"03STAIR -HANDRAIL AT GWB WALL
SCALE:
TYPICAL DETAIL
1" = 1'-0" 01 STAIR -TYPCIAL PIPE RAILING ELEVATION
SCALE:
TYPICAL DETAIL
1 1/2" = 1'-0"05STAIR -STRINGER DOWN AT LANDING
SCALE:
TYPICAL DETAIL
1 1/2" = 1'-0"07STAIR -STRINGER AT WALL DETAIL
SCALE:
TYPICAL DETAIL
1 1/2" = 1'-0"08STAIR -STRINGER AT SLAB
SCALE:
TYPICAL DETAIL
1 1/2" = 1'-0"13STAIR -LANDING AT WALL DETAIL
SCALE:
TYPICAL DETAIL
1 1/2" = 1'-0"12 STAIR -RAILING AT FLOOR EDGE
SCALE:
TYPICAL DETAIL
3" = 1'-0" 02 STAIR -WALL AT FLOOR
SCALE:
TYPICAL DETAIL
1 1/2" = 1'-0"10 STAIR -STRINGER AT FLOOR DOWN
SCALE: 1 1/2" = 1'-0" 11 STAIR -STRINGER AT FLOOR DOWN CMU
SCALE: 1 1/2" = 1'-0"09STAIR -STRINGER AT FLOOR UP
SCALE: 1 1/2" = 1'-0"06STAIR -STRINGER AT WALL BELOW DETAIL
# DESCRIPTION DATE
07/14/21
4' - 0"4' - 0"6" 1' - 0"5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
FLUID-APPLIED MEMBRANE AIR
BARRIER SHOWN DASHED [07 27
26-A1]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
SCREW-ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
6" METAL STUD [05 41 00-A4]
STRUCTURAL STEEL COLUMN [05
12 00-A2]
COLUMN PLACEMENT VARIES,
REFERENCE
OVERALL DRAWINGS AND
STRUCTURAL.
4' - 0"3' - 11 1/4"8"4 1/2"5 1/2"8"
4 1/2" 5 1/2"1' - 0"6" 1' - 0" 6"
2X EXTERIOR GRADE
PRESERVATIVE-TREATED WOOD
BLOCKING (061053) [06 10 00-A3]
FLUID-APPLIED MEMBRANE AIR
BARRIER SHOWN DASHED [07 27
26-A1]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]SCREW-ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
STOREFRONT SYSTEM, CENTER
GLAZED [08 41 00-A2]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]4' - 0"8"4 1/2"5 1/2" 1' - 0"6" STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
SCREW-ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
FLUID-APPLIED MEMBRANE AIR
BARRIER SHOWN DASHED [07 27
26-A1]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
2X EXTERIOR GRADE
PRESERVATIVE-TREATED WOOD
BLOCKING (061053) [06 10 00-A3]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4] STOREFRONT SYSTEM, CENTER
GLAZED [08 41 00-A2]
SEALANT AND BACKER ROD [07
92 00-A3]
A. REFER TO A001-A002 FOR GENERAL NOTES, WALL TYPES, SYMBOLS AND TYPICAL
CONSTRUCTION DETAILS.
B. PROVIDE BULLNOSE CMU AT ALL EXPOSED CMU CORNERS.
C. PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM WALLBOARD AT THE
APPARATUS BAY AND ALL ROOMS DIRECTLY OFF OF IT.
D. PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM WALLBOARD AT ALL WET
WALLS IN KITCHENS, AND ALL WALLS AND CEILINGS IN BATHROOMS AND
JANITOR CLOSETS.
E. PROVIDE HIGH-IMPACT GYPSUM WALLBOARD AT ALL CORRIDORS, STAIRCASES
AND THE LOBBY.
F. PLAN KEYNOTES APPLY TO SHEETS A101, A102 AND A110.
GENERAL PLAN NOTES
DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A130
PLAN DETAILS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
KIT OF PARTS
04 00 00-C8 SCREW-ATTACHED MASONRY VENEER ANCHOR, THERMAL (HB THERMAL
2-SEAL WING NUT AND 2X-HOOK TIE OR EQUAL)
04 20 00-A1 STANDARD BRICK - 3/8" JOINT
05 12 00-A2 STRUCTURAL STEEL COLUMN
05 41 00-A4 6" METAL STUD
06 10 00-A3 2X EXTERIOR GRADE PRESERVATIVE-TREATED WOOD BLOCKING (061053)
06 16 00-A2 5/8" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS
07 21 00-A2 INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD
INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS
07 27 26-A1 FLUID-APPLIED MEMBRANE AIR BARRIER SHOWN DASHED
07 92 00-A3 SEALANT AND BACKER ROD
08 41 00-A2 STOREFRONT SYSTEM, CENTER GLAZED
09 29 00-A8 5/8" TYPE "X" GYPSUM WALLBOARD
SCALE: 1" = 1'-0"01 TYP. COLUMN DETAIL
SCALE: 1" = 1'-0" 03 TYP. CORNER DETAIL
SCALE: 1" = 1'-0" 02TYP. PILASTER DETAIL
#DESCRIPTION DATE
07/14/21
A. REFER TO A201 FOR EXTERIOR MATERIAL SCHEDULE.
B. REFER TO A505 FOR WINDOW/STOREFRONT ELEVATIONS.
C. PAINT ALL EXPOSED MISC. STEEL LINTELS, PLATES, ANGLES, ETC.
XX
XX
CONTROL JOINT
EXTERIOR FINISH MATERIAL
WINDOW TYPE
GENERAL ELEVATION NOTES
SYMBOLS
BRICK MASONRY MFR: MERIDIAN BRICK
STYLE: GARNET IRONSPOT
SIZE: MODULAR
B1
TYPE PRODUCT DESCRIPTION
METAL WALL PANEL MT1
EXTERIOR MATERIALS LEGEND
BRICK MASONRY MFR: MERIDIAN BRICK
STYLE: CHCOLATE WIRECUT
SIZE: MODULAR
B2
BURNISHED BLOCK MFR: CONSUMERS CON. CORP.
STYLE: PERMA-GRIND: NATURAL
SIZE: 16X8
C1
MFR: DMI HWPC16
COLOR: MUSKET GREY
METAL COPING MT5
METAL WALL PANELMT2
METAL WALL PANEL MT3
MFR: DMI HWPC16
COLOR: DOVE GREY
MFR: DMI HWPC16
COLOR: CHARCOAL GREY
TYPE: METAL COPINGS AND TRIM, CANOPY
COLOR: CHARCOAL BLACK
BURNISHED BLOCK MFR: CONSUMERS CON. CORP.
STYLE: PERMA-GRIND: WALNUT
SIZE: 16X8
C2
CAST STONE SILLS1 MFR: MONUMENTAL STONE WORKS
COLOR: NATURAL
MT4 METAL WALL PANEL MFR: DMI HWPC16
COLOR: LEAF GREEN
FIRST FLOOR
100' -0"
THIRD FLOOR
124' -0"
SECOND FLOOR
113' -4"
ROOF -AREA A
134' -8"
AREA AAREA B
AREA AAREA B
04
A301
03
A301
01
A302
B2
S5
MT1
C1 C1
B1
C1
C2
B2
B1
C1
B1
C2 B1
B2
C2
B2
9
2 3 2
B2
B2
B2
C2
C2 C2
B2B2 B2
B1
B2 B2
S5
S2
S2 S1
S1
S2S2 S2
C1
B1
C1
B1
C1
B1
6 6 6 6
1
7 63' - 2"
127' - 11 3/4"
C1
C2 C2 C2 C2
C1 C1
C1C1
02
A306
IGL-2 IGL-2
IGL-2IGL-2IGL-2 IGL-2 IGL-2
IGL-1 IGL-1
MT5
MT2
MT3
MT5
MT4
MT5 MT5 MT5
TYP.
TYP.
MT5
MT2
TYP.
MT3
TYP.
MT1
FIRST FLOOR
100' -0"
THIRD FLOOR
124' -0"
SECOND FLOOR
113' -4"
ROOF -AREA A
134' -8"
AREA A AREA B
AREA AAREA B
2
1
S1
S1
S1
C1
B2
B2
B2
B1 C1
B1
C1
C1
C1C1
B1
B1
S1
B1
C1
6
6
6 6
6
7
B1B2
C2
C2
B2
C2 C2
02
A305
Sim03
A306
01
A306
Sim
04
A306
IGL-2
IGL-2
IGL-2 IGL-2
MT4
MT5
MT5
MT5MT5
MT5
S1
S1 S1
MT1
MT2
MT3
MT4
TYP.
TYP.
MT1
1
MT2TYP.
MT3TYP.
FIRST FLOOR
100' -0"
THIRD FLOOR
124' -0"
SECOND FLOOR
113' -4"
AA.1 B B.1 C C.1 D
ROOF -AREA A
134' -8"
01
A301
02
A302
EXTRA SPACE STORAGE
B2
S1
4
S1
S2
S2
S1
S1
S2 S1S3
3
B2
B2
B2
B2
B2
B2
B2 B2
B1
C1
B1
C1
B1B1
B1
B1
C1
B1
C1
6
1
01
A306
Sim04
A304
Sim
IGL-1IGL-1 IGL-1
IGL-2 IGL-2 IGL-2
IGL-2 IGL-2 IGL-2
MT4
FIRST FLOOR
100' -0"
THIRD FLOOR
124' -0"
SECOND FLOOR
113' -4"
ROOF -AREA A
134' -8"
02
A301
03
A302
B2
4 2 25
B2
B2
B2 B2B1
B1
C1
C2
C2C2
B1
C1
B1
C1
6
S4 S4
C1 C1
C1
01
A306
Sim
IGL-2 IGL-2
01
A307
S1
MT5
B2
C2
DANDR ID GE DRE
W
WHI
TEHI T
AR-19400087
ARC TEC
STATE OF
No.
DNDI NAAAII
R E G I STERE
DNDI NAAI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A201
EXTERIOR ELEVATIONS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
EXTERIOR ELEVATION KEYNOTE
1 NON COVERED STEEL STRUCTURE CANOPY WITH C CHANNEL FASCIA PER OWNER
STANDARDS.
2 6" DIAMETER CONCRETE FILLED STEEL BOLLARD. PROVIDE BOLLARD SLEEVE -
YELLOW COLOR.
3 EXTERIOR DOOR. REFER TO SCHEDULE
4 WALL MOUNTED ILLUMINTED SIGN PER OWNER STANDARDS
5 EXTERIOR OVERHEAD COILING DOOR. REFER TO SCHEDULE
6 PREFINISHED METAL COPING
7 TENSIONED ROD AND TURNBUCKLE ASSEMBLY.
8 THROUGH WALL SCUPPER AND PREMANUFACTURED ALUMINUM DOWNSPOUT.
PAINT TO MATCH ADJACENT WALL.
9 COVERED STEEL STRUCTURE CANOPY WITH C CHANNEL FASCIA BY COOL PLANET
AWNING COMPANY. SLOPE TO BUILDING, DRAIN INTO INTEGRATED GUTTER WITH
SINGLE DOWNSPOUT.
SCALE: 1/8" = 1'-0"01 EAST ELEVATION -AREA A
SCALE: 1/8" = 1'-0"02 EAST ELEVATION -AREA B
SCALE: 1/8" = 1'-0"03NORTH ELEVATION
SCALE: 1/8" = 1'-0"04SOUTH ELEVATION
# DESCRIPTION DATE
1 BID ADDEN. 001 10/13/2020
2 BID ADDEN. 005 03/24/2021
1
2
2
2
07/14/21
A. REFER TO A201 FOR EXTERIOR MATERIAL SCHEDULE.
B. REFER TO A505 FOR WINDOW/STOREFRONT ELEVATIONS.
C. PAINT ALL EXPOSED MISC. STEEL LINTELS, PLATES, ANGLES, ETC.
XX
XX
CONTROL JOINT
EXTERIOR FINISH MATERIAL
WINDOW TYPE
GENERAL ELEVATION NOTES
SYMBOLS
FIRST FLOOR
100' -0"
THIRD FLOOR
124' -0"
SECOND FLOOR
113' -4"
ROOF -AREA A
134' -8"
AREA BAREA A
AREA BAREA A
04
A301
03
A301
01
A302
S2
C2
6
C2 C2
C2C2 C2
B2B2 B2
B2B2 B2
S2 S2
S2
S2
S2
S1
S1
S1
B1
C1
B1
C1 B1
C1
B1
C1
B1
C1
B1
C1
B1
C1
B2
B2
B2
B2
B2 B2
6 6
6 8' - 0"8' - 0"8' - 0" 8
1
8 8
C1 C1C1
B1 B1
C1
6 8
C2 C2 C2
01
A306
Sim03
A306
Sim 01
A306
Sim
IGL-2
IGL-2 IGL-2IGL-1 IGL-1
IGL-2 IGL-2
IGL-2 IGL-2 IGL-2IGL-2 IGL-2
S1
S1
MT5
MT5
MT5 MT5 MT5 MT5 MT5MT5 MT5
MT1
MT2
MT3
MT4
TYP.
TYP.
MT1
MT2
TYP.
MT3
TYP.
FIRST FLOOR
100' -0"
THIRD FLOOR
124' -0"
SECOND FLOOR
113' -4"
ROOF -AREA A
134' -8"
AREA B AREA A
AREA BAREA A
01
A302
04
A121
C2
B2
B2
B2
C1
B2
B2
C1B2
C1
B2
C1
B1
B2 B1
S1
S1
S2 S2
C2 C2
C2C2
6
6 6 6 6
8 8
C1
C1
8 8
C1
C2 C2
B2 B2
B2
01
A306
Sim02
A305
Sim03
A306
Sim
IGL-2
IGL-2IGL-2 IGL-2
S1
S1
MT5
MT5
MT5
MT5
MT5 MT5
MT5
MT5
MT5
MT1
MT2
MT3
MT4
TYP.
TYP.
MT1
MT3
TYP.
MT2 TYP.
BRICK MASONRY MFR: MERIDIAN BRICK
STYLE: GARNET IRONSPOT
SIZE: MODULAR
B1
TYPE PRODUCT DESCRIPTION
METAL WALL PANEL MT1
EXTERIOR MATERIALS LEGEND
BRICK MASONRY MFR: MERIDIAN BRICK
STYLE: CHCOLATE WIRECUT
SIZE: MODULAR
B2
BURNISHED BLOCK MFR: CONSUMERS CON. CORP.
STYLE: PERMA-GRIND: NATURAL
SIZE: 16X8
C1
MFR: DMI HWPC16
COLOR: MUSKET GREY
METAL COPING MT5
METAL WALL PANELMT2
METAL WALL PANEL MT3
MFR: DMI HWPC16
COLOR: DOVE GREY
MFR: DMI HWPC16
COLOR: CHARCOAL GREY
TYPE: METAL COPINGS AND TRIM, CANOPY
COLOR: CHARCOAL BLACK
BURNISHED BLOCK MFR: CONSUMERS CON. CORP.
STYLE: PERMA-GRIND: WALNUT
SIZE: 16X8
C2
CAST STONE SILLS1 MFR: MONUMENTAL STONE WORKS
COLOR: NATURAL
MT4 METAL WALL PANEL MFR: DMI HWPC16
COLOR: LEAF GREEN DANDR ID GE DRE
W
WHI
TEHI T
AR-19400087
ARC TEC
STATE OF
No.
DNDI NAA AII
R E G I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A202
EXTERIOR ELEVATIONS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
EXTERIOR ELEVATION KEYNOTE
1 NON COVERED STEEL STRUCTURE CANOPY WITH C CHANNEL FASCIA PER OWNER
STANDARDS.
2 6" DIAMETER CONCRETE FILLED STEEL BOLLARD. PROVIDE BOLLARD SLEEVE -
YELLOW COLOR.
3 EXTERIOR DOOR. REFER TO SCHEDULE
4 WALL MOUNTED ILLUMINTED SIGN PER OWNER STANDARDS
5 EXTERIOR OVERHEAD COILING DOOR. REFER TO SCHEDULE
6 PREFINISHED METAL COPING
7 TENSIONED ROD AND TURNBUCKLE ASSEMBLY.
8 THROUGH WALL SCUPPER AND PREMANUFACTURED ALUMINUM DOWNSPOUT.
PAINT TO MATCH ADJACENT WALL.
9 COVERED STEEL STRUCTURE CANOPY WITH C CHANNEL FASCIA BY COOL PLANET
AWNING COMPANY. SLOPE TO BUILDING, DRAIN INTO INTEGRATED GUTTER WITH
SINGLE DOWNSPOUT.
SCALE: 1/8" = 1'-0" 01WEST ELEVATION -AREA A
SCALE: 1/8" = 1'-0"02 WEST ELEVATION -AREA B
# DESCRIPTION DATE
1 BID ADDEN. 001 10/13/2020
2 BID ADDEN. 005 03/24/2021
1
2
2
2
07/14/21
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
12 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
ROOF - AREA A
134' - 8"
04
A301
03
A30101
A302
04
A120
ARE
A A
ARE
A B
ARE
A A
ARE
A B
A303
02
A303
01
A303
03
01
A306
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
32 171819 20 21 22 23 24 25 26 27 28 29 30 31
ROOF - AREA A
134' - 8"
04
A121
ARE
A A
ARE
A B
ARE
A A
ARE
A B
A304
01
A304
03
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
AA.1 B B.1 C C.1 D
ROOF - AREA A
134' - 8"
01
A301
02
A302
A304
04
A305
01
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
AA.1 B B.1 C C.1 D
ROOF - AREA A
134' - 8"
01
A301
02
A302
A305
02
A304
05
A304
02
DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DNDI NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DREW
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A301
BUILDING SECTIONS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
KIT OF PARTS
SCALE: 1/8" = 1'-0"01 BUILDING SECTION -N/S 1
SCALE: 1/8" = 1'-0"02 BUILDING SECTION -N/S 2
SCALE: 1/8" = 1'-0"03 BUILDING SECTION -E/W 1
SCALE: 1/8" = 1'-0"04 BUILDING SECTION -E/W 2
#DESCRIPTION DATE
07/14/21
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
AA.1 B B.1 C C.1 D
ROOF - AREA A
134' - 8"
01
A301
02
A302 A305
03
A303
04
13' - 4"FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
12 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
ROOF - AREA A
134' - 8"
04
A301
03
A30101
A302
ARE
A A
ARE
A B
ARE
A A
ARE
A B
A304
03 Sim
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
32 171819 20 21 22 23 24 25 26 27 28 29 30 31
ROOF - AREA A
134' - 8"
ARE
A A
ARE
A B
ARE
A A
ARE
A B
A303
04 Sim
DANDR ID GE DRE
W
WHI
TEHI T
AR-19400087
ARC TEC
STATE OF
No.
DNDI NAA AII
R E G I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A302
BUILDING SECTIONS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
SCALE: 1/8" = 1'-0" 01 BUILDING SECTION -E/W 3
SCALE: 1/8" = 1'-0"02 BUILDING SECTION -N/S 3
SCALE: 1/8" = 1'-0"03 BUILDING SECTION -N/S 4
#DESCRIPTION DATE
07/14/21
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
1
ROOF - AREA A
134' - 8"
A310
01
A310
02
A310
03
A310
04
ES6
T/O OPENING 121' - 4"8' - 0" 2' - 8" 8' - 0" 5' - 4" 8' - 0" T/O FRAMING 140' - 8"2' - 8" 6' - 0"A311
04
ES6
STOREFRONT SYSTEM, CENTER
GLAZED [08 41 00-A2]
STOREFRONT SYSTEM, CENTER
GLAZED [08 41 00-A2]
STOREFRONT ENTRANCE DOOR
[08 41 00-A3]
REFER TO STRUCTURAL DRAWINGS FOR
FOUNDATION DETAILS.
AIR SPACE [04 00 00-D7] 5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
AIR SPACE [04 00 00-D7]
?
[04 21 13 -A1]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
6" METAL STUD [05 41 00-A4]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
?
SPECIFIED ROOFING INSULATION
[07 53 23-A3]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A3]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
E1
E1
INSULATION TYPE 5 - SPRAY
APPLIED CELLULOSE INSULATION.
FILL MISCELLANEOUS VOIDS [07 21
00-A5]
SPRAY UNDERSIDE OF DECK IN
ALL SOFFIT LOCATIONS - R30 MIN
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
11
A310
05
?10' - 8"4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
NON-STRUCTURAL METAL
FRAMING [09 22 16]
NON-STRUCTURAL METAL
FRAMING [09 22 16]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
NON-STRUCTURAL METAL
FRAMING [09 22 16]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
E1
INSULATION TYPE 5 - SPRAY
APPLIED CELLULOSE INSULATION.
FILL MISCELLANEOUS VOIDS [07 21
00-A5]
SPRAY UNDERSIDE OF DECK IN
ALL SOFFIT LOCATIONS - R30 MIN
FIRST FLOOR
100' - 0"
SECOND FLOOR
113' - 4"
17
12' - 10"A311
02
REFER TO STRUCTURAL DRAWINGS FOR
FOUNDATION DETAILS.
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
6" METAL STUD [05 41 00-A4]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
E2
INSULATION TYPE 5 - SPRAY
APPLIED CELLULOSE INSULATION.
FILL MISCELLANEOUS VOIDS [07 21
00-A5]
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
A
ROOF - AREA A
134' - 8"
A310
10
ES68' - 0"2' - 0" 6' - 0" 5' - 4" 10' - 8" A310
04
A311
03
A310
01
A310
03
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
6" METAL STUD [05 41 00-A4]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
AIR SPACE [04 00 00-D7]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
[04 21 13-A1]
AIR SPACE [04 00 00-D7]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
[04 21 13-A1]
SPECIFIED ROOFING INSULATION
[07 53 23-A3]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A3]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
E1
E1
DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A303
WALL SECTIONS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
KIT OF PARTS
04 00 00-D7 AIR SPACE
04 20 00-A1 STANDARD BRICK - 3/8" JOINT
04 21 13-A1
04 22 00-D1 4" X 8" X 16" GROUND FACE CMU
05 13 00-A3 METAL ROOF DECK - REFER TO STRUCTURAL DRAWINGS
05 41 00-A4 6" METAL STUD
06 16 00-A2 5/8" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS
07 21 00-A2 INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD
INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS
07 21 00-A5 INSULATION TYPE 5 - SPRAY APPLIED CELLULOSE INSULATION. FILL
MISCELLANEOUS VOIDS
07 53 23-A3 SPECIFIED ROOFING INSULATION
08 41 00-A2 STOREFRONT SYSTEM, CENTER GLAZED
08 41 00-A3 STOREFRONT ENTRANCE DOOR
09 29 00-A8 5/8" TYPE "X" GYPSUM WALLBOARD
SCALE: 1/2" = 1'-0" 02WALL SECTION
SCALE: 1/2" = 1'-0" 01 WALL SECTION
SCALE: 1/2" = 1'-0"03 WALL SECTION
SCALE: 1/2" = 1'-0"04WALL SECTION
#DESCRIPTION DATE
07/14/21
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
28
A310
06
13' - 4"CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
A
ROOF - AREA A
134' - 8"
E1
E1
8' - 0" 5' - 4" 8' - 0" 2' - 8" 8' - 0"A311
04 Sim
[04 21 13 -A1]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
AIR SPACE [04 00 00 -D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00 -A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
6" METAL STUD [05 41 00-A4]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
[04 21 13-A1]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
SPECIFIED ROOFING INSULATION
[07 53 23-A3]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A3]
?
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
STANDARD BRICK - 3/8TH JOINT [04
20 00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
A310
04
A310
02
A310
03
E5 - WEST WALL ONLY,
REFER TO A001.
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
D
ROOF - AREA A
134' - 8"10' - 8" 10' - 8" 4' - 8"4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
AIR SPACE [04 00 00-D7]
FORMED METAL WALL PANELS -
PREFINISHED [07 41 14-A1]
[R10]
3-5/8" METAL STUD [05 41 00-A2]
SPECIFIED ROOFING INSULATION
[07 53 23-A3]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A3]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
E3
A310
11
INSULATION TYPE 5 - SPRAY
APPLIED CELLULOSE INSULATION.
FILL MISCELLANEOUS VOIDS [07 21
00-A5]
SPRAY UNDERSIDE OF DECK IN
ALL SOFFIT LOCATIONS - R30 MIN
FIRST FLOOR
100' - 0"
SECOND FLOOR
113' - 4"
C
13' - 4"A311
02 Sim
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
INSULATION TYPE 2 -STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
AIR SPACE [04 00 00 -D7]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
E2
INSULATION TYPE 5 - SPRAY
APPLIED CELLULOSE INSULATION.
FILL MISCELLANEOUS VOIDS [07 21
00-A5]DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DNDI NAA AII
R E G I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
09/11/2020
A304
WALL SECTIONS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
SCALE: 1/2" = 1'-0" 01WALL SECTION
SCALE: 1/2" = 1'-0" 03 WALL SECTION
SCALE: 1/2" = 1'-0" 04WALL SECTION
SCALE: 1/2" = 1'-0"05WALL SECTION
SCALE: 1/2" = 1'-0"02 WALL SECTION
#DESCRIPTION DATE
1 BID ADDEN. 001 10/13/2020NOT USED1
07/14/21
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
C.1D
ROOF - AREA A
134' - 8"
A310
07
A310
08
8' - 0" 5' - 4" 8' - 0" 2' - 8" 8' - 0" 2' - 8"A311
04 Sim
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
1/2" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A1]
[04 21 13-A1]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
AIR SPACE [04 00 00-D7]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
6" METAL STUD [05 41 00-A4]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
[04 21 13-A1]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
AIR SPACE [04 00 00-D7]?
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A3]
SPECIFIED ROOFING INSULATION
[07 53 23-A3]
E1
E1
E1
A310
03
A310
04
INSULATION TYPE 5 - SPRAY
APPLIED CELLULOSE INSULATION.
FILL MISCELLANEOUS VOIDS [07 21
00-A5]
SPRAY UNDERSIDE OF DECK IN
ALL SOFFIT LOCATIONS - R30 MIN
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
A
ROOF - AREA A
134' - 8"2' - 0" 11' - 4" 10' - 8" 10' - 8"A311
06
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
FORMED METAL WALL PANELS -
PREFINISHED [07 41 14-A1]
AIR SPACE [04 00 00-D7]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
6" METAL STUD [05 41 00-A4]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
SPECIFIED ROOFING INSULATION
[07 53 23-A3]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A3]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
E3
E2
A310
11
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
C.1 D
ROOF - AREA A
134' - 8"
A310
09
12' - 11 3/4" 11' - 0 1/4" 8' - 0"3 5/8"
A311
02 Sim
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
6" METAL STUD [05 41 00-A4]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
[04 21 13-A1]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
AIR SPACE [04 00 00-D7]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A3]
SPECIFIED ROOFING INSULATION
[07 53 23-A3]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
E2
E2
E2
A310
04
INSULATION TYPE 5 - SPRAY
APPLIED CELLULOSE INSULATION.
FILL MISCELLANEOUS VOIDS [07 21
00-A5]
SPRAY UNDERSIDE OF DECK IN
ALL SOFFIT LOCATIONS - R30 MIN
DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A305
WALL SECTIONS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
SCALE: 1/2" = 1'-0" 01 WALL SECTION
SCALE: 1/2" = 1'-0" 02WALL SECTION
SCALE: 1/2" = 1'-0" 03 WALL SECTION
#DESCRIPTION DATE
07/14/21
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
A
ROOF - AREA A
134' - 8"
A311
01
4" X 8" X 16" CMU - 2 CORE [04 22
00-A1]
?
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
QUEEN BRICK - 3/8" JOINT [04 20
00-A3]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
QUEEN BRICK - 3/8" JOINT [04 20
00-A3]
SPECIFIED ROOFING INSULATION
[07 53 23-A3]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A3]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
E2
E1
A310
04
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
D
ROOF - AREA A
134' - 8"
4" X 8" X 16" CMU - 2 CORE [04 22
00-A1]
6" METAL STUD [05 41 00-A4]
6" METAL STUD [05 41 00-A4]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A3]
SPECIFIED ROOFING INSULATION
[07 53 23-A3]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
A310
04
E2
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
D
ROOF - AREA A
134' - 8"
A311
02 Sim
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2] 5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
6" METAL STUD [05 41 00-A4]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A3]
SPECIFIED ROOFING INSULATION
[07 53 23-A3]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
A310
04
E2
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
D
ROOF - AREA A
134' - 8"
A311
05
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
AIR SPACE [04 00 00-D7]
[04 21 13-A1]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
6" METAL STUD [05 41 00-A4]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
AIR SPACE [04 00 00-D7]
[04 21 13-A1]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
6" METAL STUD [05 41 00-A4]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
6" METAL STUD [05 41 00-A4]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
[04 21 13-A1]
SPECIFIED ROOFING INSULATION
[07 53 23-A3]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A3]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
A310
04
E1
E1
E1
DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A306
WALL SECTIONS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
SCALE: 1/2" = 1'-0"01Pilaster
SCALE: 1/2" = 1'-0" 02Section 3
SCALE: 1/2" = 1'-0" 03 Block Full Height
SCALE: 1/2" = 1'-0" 04GLAZING OVER BLOCK
#DESCRIPTION DATE
07/14/21
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
32
ROOF - AREA A
134' - 8"
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
8" X 8" X 16" GROUND FACE CMU
[04 22 00-D3]
[04 21 13-A1]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
[04 21 13-A1]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
[04 21 13-A1]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
SPECIFIED ROOFING INSULATION
[07 53 23-A3]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A3]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
A310
01
A310
04
A311
02 Sim
ES4
DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A307
WALL SECTIONS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
SCALE: 1/2" = 1'-0" 01BRICK ON BLOCK
#DESCRIPTION DATE
07/14/21
2 COURSES5 3/8"2 COURSES 5 3/8" 2 COURSES 5 3/8" DOUBLE SOLDIER COURSE 1' - 4" 5 7/8" 4 1/2" 4" 3 5/8"
6" 8 3/8" 1" 2 5/8"
1"
1"
1"
6" 1' - 0 3/8"B2 B1SOLID SOLDIER WITH 3/8" JOINT
[04 20 00-B4]
SCREW-ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A3]
SPECIFIED ROOFING INSULATION
[07 53 23-A3]
12" METAL STUD [0541 00-A5]
6" METAL STUD [05 41 00-A4]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
STRUCTURAL STEEL SHELF ANGLE
[05 12 00-A5]
CANT STRIP PER ROOF MEMBRANE
MFR REQUIREMENTS [07 54 23-A7]
TPO MEMBRANE ROOFING
SYSTEM OVER SCHEDULED RIGID
INSULATION - REFER ROOF PLAN
AND SPECIFICATIONS [07 54
23-A1]
1' - 2 5/8"SOLDIER COURSE8"1/2"
4 1/2" 4"5"B2 S12X EXTERIOR GRADE
PRESERVATIVE-TREATED WOOD
BLOCKING (061053) [06 10 00-A3]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2] AIR SPACE [04 00 00-D7]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
6" METAL STUD [05 41 00-A4]
SCREW-ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
AISC STEEL ANGLE 6"X4"
[05 12 00-A5]
METAL ROOF DECK -REFER TO
STRUCTURAL DRAWINGS [05 13
00-A3]
12" METAL STUD [05 41 00-A5]
SOLID SOLDIER WITH 3/8" JOINT
[04 20 00-B4]
11"0"3/8" NON -STRUCTURAL METAL
FRAMING [09 22 16]
SCREW-ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
12" METAL STUD [05 41 00-A5]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
STRUCTURAL STEEL SHELF ANGLE
[05 12 00-A5]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
EIFS ON 1" INSULATION BOARD [07
24 13-A1]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
EIFS ON 1" INSULATION BOARD [07
24 13-A1]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
CIP CONRETE SLAB ON GRADE
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK -REFER TO
STRUCTURAL DRAWINGS [05 13
00-A3]
4 1/2" 6 1/8"
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
1/2" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A1]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
AISC STEEL ANGLE 6"X4"
[05 12 00-A5]
12" METAL STUD [05 41 00-A5]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
EIFS ON 1" INSULATION BOARD [07
24 13-A1]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
SCREW-ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
12" METAL STUD [05 41 00-A5]
6" METAL STUD [05 41 00-A4]
6" METAL STUD [05 41 00-A4]
EIFS ON 1" INSULATION BOARD [07
24 13-A1]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
SOLID SOLDIER WITH 3/8" JOINT
[04 20 00-B4]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
5/8"
6"
5/8"
1 1/2"
2 1/4"
3 5/8"
1/2"
5 1/2" 4 1/2" 4" 4"
5 1/2" 4 1/2" 4" 4"
6" 8"5"5"SOLDIER COURSE8" B2 S15/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
6" METAL STUD [05 41 00-A4]
AIR SPACE [04 00 00-D7]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
12" METAL STUD [05 41 00 A5]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
SOLID SOLDIER WITH 3/8" JOINT
[04 20 00-B4]
2X EXTERIOR GRADE
PRESERVATIVE-TREATED WOOD
BLOCKING (061053) [06 10 00-A3]
SCREW-ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
AISC STEEL ANGLE 6"X4"
[05 12 00-A5]DOUBLE HEADER COURSE1' - 4"6" METAL STUD [05 41 00 -A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
AIR SPACE [04 00 00-D7]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
SOLID SOLDIER WITH 3/8" JOINT
[04 20 00-B4]
2X EXTERIOR GRADE
PRESERVATIVE-TREATED WOOD
BLOCKING (061053) [06 10 00-A3]
COMPOSITE NAILBASE SHEATHING
- 1-1/2" THICK, R6.6 MIN [06 16
00-A7]
PREMANUFACTURERED METAL
COPING TO MEET ANSI/SPRI ES-1
[07 71 00-A1]8"WRAP MEMBRANE OVER AND
DOWN FACE OF WALL.
2X122X8
TPO MEMBRANE ROOFING
SYSTEM OVER SCHEDULED RIGID
INSULATION - REFER ROOF PLAN
AND SPECIFICATIONS [07 54
23-A1]
INSULATION TYPE 4 - KRAFT FACED
FIBERGLASS BATT INSULATION, R19
MIN. [07 21 00-A4]
1 1/2" 6" 1' - 0"
1' - 7 1/2"
SCREW -ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
3 5/8" 4 1/2"7 5/8"3/8" STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
SCREW-ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
AISC STEEL ANGLE 6"X4"
[05 12 00-A5]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-
A8]
12" METAL STUD [05 41 00-A5]
WRAP MEMBRANE OVER AND
DOWN FACE OF WALL.
2X8 2X8
FORMED METAL WALL PANELS -
PREFINISHED [07 41 14-A1]
AIR SPACE [04 00 00-D7]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
6" METAL STUD [05 41 00-A4]
2X EXTERIOR GRADE
PRESERVATIVE-TREATED WOOD
BLOCKING (061053) [06 10 00-A3]
TPO MEMBRANE ROOFING
SYSTEM OVER SCHEDULED RIGID
INSULATION - REFER ROOF PLAN
AND SPECIFICATIONS [07 54
23-A1]
[09 22 16.13.K4]
PREMANUFACTURERED METAL
COPING TO MEET ANSI/SPRI ES-1
[07 71 00-A1]DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A310
SECTION DETAILS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
KIT OF PARTS
04 00 00-C8 SCREW-ATTACHED MASONRY VENEER ANCHOR, THERMAL (HB THERMAL
2-SEAL WING NUT AND 2X-HOOK TIE OR EQUAL)
04 00 00-D7 AIR SPACE
04 20 00-A1 STANDARD BRICK - 3/8" JOINT
04 20 00-B4 SOLID SOLDIER WITH 3/8" JOINT
04 22 00-D1 4" X 8" X 16" GROUND FACE CMU
05 12 00-A5 STRUCTURAL STEEL SHELF ANGLE
05 13 00-A3 METAL ROOF DECK - REFER TO STRUCTURAL DRAWINGS
05 41 00-A4 6" METAL STUD
06 10 00-A3 2X EXTERIOR GRADE PRESERVATIVE-TREATED WOOD BLOCKING (061053)
06 16 00-A1 1/2" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS
06 16 00-A2 5/8" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS
06 16 00-A7 COMPOSITE NAILBASE SHEATHING - 1-1/2" THICK, R6.6 MIN
07 21 00-A2 INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD
INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS
07 21 00-A4 INSULATION TYPE 4 - KRAFT FACED FIBERGLASS BATT INSULATION, R19 MIN.
07 24 13-A1 EIFS ON 1" INSULATION BOARD
07 41 14-A1 FORMED METAL WALL PANELS - PREFINISHED
07 53 23-A3 SPECIFIED ROOFING INSULATION
07 54 23-A1 TPO MEMBRANE ROOFING SYSTEM OVER SCHEDULED RIGID INSULATION -
REFER ROOF PLAN AND SPECIFICATIONS
07 54 23-A7 CANT STRIP PER ROOF MEMBRANE MFR REQUIREMENTS
07 71 00-A1 PREMANUFACTURERED METAL COPING TO MEET ANSI/SPRI ES-1
09 29 00-A8 5/8" TYPE "X" GYPSUM WALLBOARD
SCALE: 1 1/2" = 1'-0" 01 BUILDING SECTION DETAIL 01
SCALE: 1 1/2" = 1'-0" 02BUILDING SECTION DETAIL 02
SCALE: 1 1/2" = 1'-0"05BUILDING SECTION DETAIL 05
SCALE: 1 1/2" = 1'-0" 06BUILDING SECTION DETAIL 06
SCALE: 1 1/2" = 1'-0" 07BUILDING SECTION DETAIL 07
SCALE: 1 1/2" = 1'-0"09BUILDING SECTION DETAIL 09
SCALE: 1 1/2" = 1'-0"10BUILDING SECTION DETAIL 10
SCALE: 1 1/2" = 1'-0" 03 BUILDING SECTION DETAIL 03
SCALE: 1 1/2" = 1'-0" 04BUILDING SECTION DETAIL 04
SCALE: 1 1/2" = 1'-0" 08BUILDING SECTION DETAIL 08
#DESCRIPTION DATE
SCALE: 1 1/2" = 1'-0" 11 METAL WALL COPING
07/14/21
SOLID GROUND FACE CMU SILL BLOCK, MATCH
ADJACENT CMU.
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
VAPOR BARRIER [03 30 00-B6]
GRAVEL
REFER TO STRUCTUTRAL
INSULATION TYPE 2 -STUD CAVITY
WALL: EXTRUDED-POLYSTYRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUN. TAPE ALL SEAMS
[07 021 00-A2]
GROUT SOLID BELOW DOOR
STOREFRONT SYSTEM, THERMALLY
BROKEN, FRONT GLAZED [08 41
00-A1]
VAPOR BARRIER [03 30 00-B6]
GRAVEL
REFER TO STRUCTURAL
BOND BEAM 8" X 8" X 16"
[04 20 00-B2]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
MORTAR NET [04 20 00-G5]
THROUGH WALL FLASHING
[04 20 00-G2]
MESH WEEP [04 20 00-G4]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 -STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING -TAPE ALL SEAMS [06
16 00-A2]
SCREW -ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
GROUT SOLID BELOW FLASHING.
VAPOR BARRIER [03 30 00-B6]
GRAVEL
REFER TO STRUCTURAL
BOND BEAM 8" X 8" X 16"
[04 20 00-B2]
MORTAR NET [04 20 00-G5]
THROUGH WALL FLASHING
[04 20 00-G2]
MESH WEEP [04 20 00-G4]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING -TAPE ALL SEAMS [06
16 00-A2]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 -STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
SCREW -ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
GROUT SOLID BELOW FLASHING.
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING -TAPE ALL SEAMS [06
16 00-A2]
INSULATION TYPE 2 -STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
STANDARD BRICK -3/8" JOINT [04
20 00-A1]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
AIR SPACE [04 00 00-D7]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
VAPOR BARRIER [03 30 00-B6]
GRAVELMORTAR NET [04 20 00-G5]
THROUGH WALL FLASHING
[04 20 00-G2]
MESH WEEP [04 20 00-G4]
REFER TO STRUCTURAL
BOND BEAM 8" X 8" X 16"
[04 20 00-B2]
SCREW -ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
SCREW -ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
GROUT SOLID BELOW FLASHING.
FLUID-APPLIED MEMBRANE AIR
BARRIER SHOWN DASHED [07 27
26-A1]
VAPOR BARRIER [03 30 00-B6]
GRAVEL
REFER TO STRUCTURAL
BOND BEAM 8" X 8" X 16"
[04 20 00-B2]
MORTAR NET [04 20 00-G5]
THROUGH WALL FLASHING
[04 20 00-G2]
MESH WEEP [04 20 00-G4]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
INSULATION TYPE 2 -STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
SOLID GROUND FACE CMU SILL BLOCK,
MATCH
ADJACENT CMU.
2X EXTERIOR GRADE
PRESERVATIVE-TREATD WOOD
BLOCKING (061053) [06 10 00-A3]
GROUT SOLID BELOW FLASHING.2' - 0"FLUID-APPLIED MEMBRANE AIR
BARRIER SHOWN DASHED [07 27
26-A1]
VAPOR BARRIER [03 30 00-B6]
GRAVEL
REFER TO STRUCTURAL
BOND BEAM 8" X 8" X 16"
[04 20 00-B2]
MORTAR NET [04 20 00-G5]
THROUGH WALL FLASHING
[04 20 00-G2]
MESH WEEP [04 20 00-G4]
QUEEN BRCK -3/8" JOINT [04 20
00-A3]
2X EXTERIOR GRADE
PRESERVATIVE-TREATD WOOD
BLOCKING (061053) [06 10 00-A3]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
INSULATION TYPE 2 -STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
AIR SPACE [04 00 00-D7]
SCREW -ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
INTERIOR LIGHT GUAGE ZEES
[09 22 16 13-K4]
GROUT SOLID BELOW FLASHING
FORMED METAL WALL PANELS -
PREFINISHED [07 41 14-A1]
CONTINUOUS PREFINISHED 0.040
ALUMINUM BRAKE METAL
FLASHING [05 75 00-A2]
INSULATION TYPE 4 -KRAFT FACED
FIBERGLASS BATT INSULATION, R19
MIN. [07 21 00-A4]
FLUID-APPLIED MEMBRANE AIR
BARRIER SHOWN DASHED [07 27
26-A1]DANDR ID GE DRE
W
WHI
TEHI T
AR-19400087
ARC TEC
STATE OF
No.
DNDI NAA AII
R E G I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A311
SECTION DETAILS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
SCALE: 1 1/2" = 1'-0"04GLAZING OVER FOUNDATION
SCALE: 1 1/2" = 1'-0" 02BLOCK OVER FOUNDATION
SCALE: 1 1/2" = 1'-0"03 BLOCK OVER BLOCK
SCALE: 1 1/2" = 1'-0" 01 PILASTER FOUNDATION
SCALE: 1 1/2" = 1'-0"05GLAZING OVER BLOCK
SCALE: 1 1/2" = 1'-0"06METAL OVER BLOCK
# DESCRIPTION DATE
1 BID ADDEN. 001 10/13/2020
2 BID ADDEN. 005 03/24/2021
KIT OF PARTS
03 30 00-A1 CIP CONCRETE SLAB ON GRADE - REFER TO STRUCTURAL DRAWINGS
04 00 00-C8 SCREW-ATTACHED MASONRY VENEER ANCHOR, THERMAL (HB THERMAL
2-SEAL WING NUT AND 2X-HOOK TIE OR EQUAL)
04 00 00-D7 AIR SPACE
04 20 00-A1 STANDARD BRICK - 3/8" JOINT
04 22 00-D1 4" X 8" X 16" GROUND FACE CMU
05 41 00-A4 6" METAL STUD
05 75 00-A2 CONTINUOUS PREFINISHED 0.040 ALUMINUM BRAKE METAL FLASHING
06 16 00-A2 5/8" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS
07 21 00-A2 INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD
INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS
07 21 00-A4 INSULATION TYPE 4 - KRAFT FACED FIBERGLASS BATT INSULATION, R19 MIN.
07 27 26-A1 FLUID-APPLIED MEMBRANE AIR BARRIER SHOWN DASHED
07 41 14-A1 FORMED METAL WALL PANELS - PREFINISHED
08 41 00-A1 STOREFRONT SYSTEM, THERMALLY BROKEN, FRONT GLAZED
09 29 00-A8 5/8" TYPE "X" GYPSUM WALLBOARD
1
2
07/14/21
A.REFER TO CEILING PLAN FOR ALL CEILING HEIGHTS.
B.ALL GRIDS ARE CENTERED IN ROOMS EACH DIRECTION UNLESS NOTED
OTHERWISE.
C.LOCATE CEILING GRIDS WITHIN ROOMS SUCH THAT BORDERS CONTAIN NOT LESS
THAN 1/2 TILE WIDTH, UNLESS OTHERWISE INDICATED.
D.CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS WITHIN INDIVIDUAL
CEILING PANELS, SUCH AS SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES, ETC.,
UNLESS OTHERWISE INDICATED.
E.PAINT ALL EXPOSED GYPSUM WALLBOARD SURFACES UNLESS NOTED
OTHERWISE. REFER TO FINISH PLAN FOR COLORS.
F. ALL EXPOSED DUCTWORK, PIPING, CONDUITS ETC. SHALL BE PAINTED. COLOR
TO MATCH CEILING OR EXPOSED STRUCTURE UNLESS OTHERWISE NOTED.
G.PROVIDE CONTROL JOINTS IN GYPSUM WALLBOARD CEILINGS AT 20'
MAXIMUM. VERIFY LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION.
H.COORDINATE REFLECTED CEILING PLAN WITH MECHANICAL, PLUMBING,
ELECTRICAL, AND LIFE SAFETY PLANS. PROVIDE COORDINATION DRAWINGS FOR
REVIEW PRIOR TO CEILING INSTALLATION.
I. LIGHT FIXTURES, SPRINKLER HEADS, HVAC SUPPLY AND RETURN GRILLES ARE
SHOWN FOR LOCATION ONLY. REFER TO MEP DRAWINGS FOR ADDITIONAL
INFORMATION
J. PROVIDE ACOUSTICAL CEILING HOLD-DOWN CLIPS IN VESTIBULES. IN ROOMS
WITH EXTERIOR ENTRANCE DOORS PROVIDE HOLD-DOWN CLIPS FOR 10' IN ALL
DIRECTION OF DOORWAY.
K.CEILING ACCESS PANELS INDICATED ARE NOT INTENDED TO LIMIT NUMBER OF
PANELS REQUIRED. PANEL QUANTITY SHALL BE SUFFICIENT TO PROVIDE REQUIRED
ACCESS WHETHER OR NOT INDICATED ON THE DRAWINGS. VERIFY LOCATIONS
WITH ARCHITECT PRIOR TO INSTALLATION.
GENERAL CEILING PLAN NOTES
CEILING LEGEND
2x2 LAY-IN CEILING GRID
4x4 LAY-IN CEILING GRID
GYPSUM BOARD CEILING OR
GYPSUM BOARD BULKHEAD
EXPOSED STRUCTURE
CEILING TAG
CEILING TYPE
CEILING HEIGHT
X
X
B
8' - 0"
B
11' - 4"
B
12' - 10"
1
1
1
2
2
2
DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DNDI NAA AII
R E G I STERE
DNDI NA AI
HI TARC TECDANDRID GE DREW
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
MA
GSD
8.27.2020
A401
SOFFIT REFLECTED CEILING
PLAN
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
CEILING TYPES
TYPE DESCRIPTION
GYPSUM WALLBOARD BULKHEAD ON 3-5/8" INTERIOR METAL FRAMING.
RETURN FACE OF DRYWALL TO CEILING OR STRUCTURE ABOVE.
REFER TO FINISH PLANS FOR PAINTING.
A ACOUSTICAL PANEL TYPE A IN GRID TYPE A. 24" X 24" ACOUSTICAL
CEILING TO BE ARMSTRONG OPTIMA 3355 SQUARE TEGULAR
INSTALLED IN 9/16" SILHOUETTE XL BOLT SLOT 1/8"
REVEAL SUSPENSION GRID.
B EIFS SOFFIT ON 5/8" GLASS-MAT GYPSUM WALLBOARD AND 6" METAL STUDS,
TYPICAL.
G GYPSUM WALLBOARD BULKHEAD ON 3-5/8" INTERIOR METAL FRAMING.
RETURN FACE OF DRYWALL TO CEILING OR STRUCTURE ABOVE.
REFER TO FINISH PLANS FOR PAINTING.
REFLECTED CEILING KEYNOTES
1 FIRE PROTECTION CONTRACTOR TO PROVIDE ADEQUETE SPRINKLER HEAD
COVERAGE UNDER SOFFIT AREAS. PROVIDE EXTERIOR DRY SPRINKLER HEADS
LOW-VOLTAGE ACUATORS.
SCALE: 1/8" = 1'-0" 01 SOFFIT REFLECTED CEILING PLAN -AREA A
SCALE: 1/8" = 1'-0"02FIRST FLOOR REFLECTED CEILING PLAN
#DESCRIPTION DATE
07/14/21
MATERIALS:
HM = HOLLOW METAL
IHM = INSULATED HOLLOW METAL
SCW = SOLID CORE WOOD
AL = ALUMINUM
STL = STEEL, GALVANIZED
IMP= INSULATED METAL PANEL
FINISHES:
CA = CLEAR ANODIZED
PRE = FACTORY PREFINISHED
PT = PAINTED
GENERAL DOOR NOTES
DOOR & FRAME MATERIAL ABBREVIATIONS
DOOR SCHEDULE REMARKS
A. REFER TO THE PROJECT MANUAL FOR DOOR HARDWARE SETS.
B. ALL HOLLOW METAL DOORS AND FRAMES TO RECEIVE 3-COAT PAINT SYSTEM -
PRIME, INTERMEDIATE AND FINISH COATS. REFER TO PAINTING SPECIFICATION.
REFER TO FINISH PLAN AND EXTERIOR ELEVATIONS FOR COLOR. REFER TO THE
PROJECT MANUAL FOR THE GLAZING SCHEDULE.
C. REFER TO A501 FOR GLAZING SCHEDULE.
1. SLIDING ENTRANCE DOORS TO BE SNALEY DURA GLIDE 3000 SINGLE SLIDE AUTO
DOORS OR SIMILAR WITH FULL BREAKAWAY, ACCESS CONTROL, RECESSED PANIC
HARDWARE AND FAIL SECURE SOLENOID LOCKS AND KEYED FUNCTION
SWITCHES. ASSA ABLOY SL SERIES DOOR SYSTEM ALSO ACCEPTABLE. OTHER
MANUFACTURERS WILL BE CONSIDERED WITH PROPER DOCUMENTATION
SHOWING EQUIVALENCY.
1/4" FULLY TEMPERED CLEAR FLOAT GLASSGL-1
**REFER TO PROJECT MANUAL FOR COMPLETE GLAZING SPECIFICATION.
**CONTRACTOR TO PROVIDE FULLY TEMPERED LITES IN ALL LOCATIONS
REQUIRED BY CODE INCLUDING BATHROOMS AND WITHIN 30" OF FLOOR
GLAZING SCHEDULE
1" CLEAR INSULATING GLASS WITH LOW-E COATING, FULLY TEMPEREDIGL-1
IGL-2 1" SPANDREL INSULATING GLASS, FULLY TEMPERED
D1 REF. SCHED.REF. SCHED. REF. SCHED.REF. SCHED. REF. SCHED.REF. SCHED. REF. SCHED.REF. SCHED. REF. SCHED.REF. SCHED.
D2 D3 D4 D5
F1 F2
2" REF. SCHED. 2"2" REF. SCHED. HOLLOW METAL
FRAME
HOLLOW METAL
FRAME 4"REF. SCHED. 2" REF. SCHED. 2"
INTERIOR WALL CONSTRUCTION
REFER TO PLANS FOR TYPE
HOLLOW METAL FRAME - REFER SCHEDULE
DOOR - REFER SCHEDULE
SEALANT JOINT AT FRAME PERIMETER TYP.
METAL STUD HEADER. SIZE PER
OPENING WIDTH
4 7/8"
HOLLOW METAL FRAME CLIP4" 2"
INTERIOR WALL CONSTRUCTION
REFER TO PLANS FOR TYPE
DOUBLE STUD AT JAMB TYP.
HOLLOW METAL FRAME - REFER
SCHEDULE
DOOR - REFER SCHEDULE
SEALANT JOINT TYP. 4 7/8"INTERIOR WALL CONSTRUCTION
REFER TO PLANS FOR TYPE
HOLLOW METAL FRAME - REFER SCHEDULE
DOOR - REFER SCHEDULE
SEALANT JOINT AT FRAME PERIMETER TYP.
7 1/4"
METAL STUD HEADER. SIZE PER
OPENING WIDTH
HOLLOW METAL FRAME CLIP4" 2"
INTERIOR WALL CONSTRUCTION
REFER TO PLANS FOR TYPE
DOUBLE STUD AT JAMB TYP.
HOLLOW METAL FRAME - REFER
SCHEDULE
DOOR - REFER SCHEDULE
SEALANT JOINT TYP.7 1/4"7 1/4"
BOND BEAM REFER TO
STRUCTRUAL DWG'S
4"SEALANT JOINT AT FRAME PERIMTER TYP.
HOLLOW METAL FRAME - REFER SCHEDULE
DOOR - REFER SCHEDULE
HOLLOW METAL FRAME -
REFER SCHEDULE
DOOR - REFER SCHEDULE
2"6"CMU FRAME CLIP
BULLNOSE
CMU WALL
SEALANT AT PERIMETER TYP.
EACH DOOR SHALL HAVE:
DOOR HARDWARE SETS
SET #01:
EXTERIOR RATED EXIT ONLY FROM STAIR
3 EA
1 EA
1 EA
1 EA
1 EA
1 SET
1 EA
1 EA
HINGE
FIRE EXIT HARDWARE
SURFACE CLOSER
CUSH SHOE SUPPORT
KICK PLATE
SEALS
DOOR SWEEP
THRESHOLD
5BBI 4.5 X 4.5 NRP
98-EO-F
4040XP CUSH TBWMS
4040XP-30
8400 10" X 1 1/2" LDW B4E
700SA
C627A
425HD
EACH DOOR SHALL HAVE:
SET #02:
EXTERIOR EXIT WITH PINCODE EXIT TRIM
3 EA
1 EA
1 EA
1 EA
1 EA
1 EA
1 SET
1 EA
1 EA
1 EA
1 EA
HINGE
PANIC HARDWARE
ELECTRIC STRIKE
SURFACE CLOSER
CUSH SHOE SUPPORT
KICK PLATE
SEALS
DOOR SWEEP
THRESHOLD
CREDENTIAL READER
POWER SUPPLY
5BBI 4.5 X 4.5 NRP
98-L-996-06
6300 FSE
4040XP SCUSH TBWMS
4040XP-30
8400 10" X 1 1/2" LDW B4E
700SA
C627A
425HD
PTI KEYPAD
AS REQ'D
EACH DOOR SHALL HAVE:
SET #02.2:
BI-PARTING ENTRANCE DOOR WITH PINCODE READER
1 EA
ELECTRONIC KEYPAD
REMAINING HARDWARE
KP2000EM
BY DOOR MFG
EACH DOOR SHALL HAVE:
SET #03:
INTERIOR EQUIPMENT ROOM DOOR
3 EA
1 EA
1 EA
1 EA
3 EA
HINGE
STOREROOM LOCK
SURFACE CLOSER
CUSH SHOE SUPPORT
SILENCER
5BB1 4.5 X 4.5 NRP
ND80PD RHO
4040XP SHCUSH
4040XP-30
SR64
SET #04:
EACH DOOR SHALL HAVE:
SET #05:
1 EA
1 EA
1 EA
1 EA
1 EA
1 SET
1 EA
1 EA
1 EA
1 EA
1 EA
CONT. HINGE
DEADBOLT
MORTISE CYLINDER
INDICATOR
DEADBOLT LEVER
PUSH/PULL
SURFACE CLOSER
MOUNTING CLOSER
PERIMETER SEALS
DOOR SWEEP
THRESHOLD
112HD
MS1851
20-001 114
4089
4550
9190-10"-STD
4011 MC TBWMS
4010-18
DOOR MFG STD
DOOR MFG STD
DOOR MFG STD
SET #06:
EACH DOOR SHALL HAVE:
RATED INTERIOR DOOR, SINGLE
3 EA
1 EA
1 EA
1 EA
1 SET
1 EA
1 EA
HINGE
PANIC HARDWARE
SURFACE CLOSER
CUSH SHOE SUPPORT
SEALS
DOOR SWEEP
THRESHOLD
5BBI 4.5 X 4.5 NRP
98-L-996-06
4040XP SCUSH TBWMS
8400 10" X 1 1/2" LDW B4E
700SA
C627A
425HD -36"
SET #08:
EXTERIOR OFFICE
EACH DOOR SHALL HAVE:
3 EA
1 EA
1 EA
1 EA
1 EA
1 SET
1 EA
1 EA
HINGE
PASSAGE SET
SGL CYL DEADBOLT
SURFACE CLOSER
WALL STOP
SEALS
DOOR SWEEP
THRESHOLD
5BBI 4.5 X 4.5 NRP
F10 LAT
B560P
4040XP
WS407CCV
700SA
C627A
425HD
SET #09:
INTERIOR OFFICE PRIVACY
EACH DOOR SHALL HAVE:
3 EA
1 EA
1 EA
1 EA
1 EA
3 EA
HINGE
PRIVACY LOCK
SURFACE CLOSER
WALL STOP
KICK PLATE
SILENCER
5BBI 4.5 X 4.5
AL40S SAT
4040XP SHCUSH
WS407CCV
8400 10" X 1 1/2" LDW B4E
SR64
SET #10:
INTERIOR OFFICE PASSAGE
EACH DOOR SHALL HAVE:
3 EA
1 EA
1 EA
1 EA
1 EA
3 EA
HINGE
PASSAGE LOCK
SURFACE CLOSER
WALL STOP
KICK PLATE
SILENCER
5BBI 4.5 X 4.5
AL40S SAT
4040XP SHCUSH
WS407CCV
8400 10" X 1 1/2" LDW B4E
SR64
SET #07:
EXTERIOR STOREROOM
EACH DOOR SHALL HAVE:
3 EA
1 EA
1 EA
1 EA
1 SET
1 EA
1 EA
HINGE
STOREROOM SET
SGL CYL DEADBOLT
SURFACE CLOSER
SEALS
DOOR SWEEP
THRESHOLD
5BBI 4.5 X 4.5 NRP
ND80PD RHO
B560P
4040XP
700SA
C627A
425HD
NOT U
S
E
D
DANDR ID GE DRE
W
WHI
TEHI T
AR-19400087
ARC TEC
STATE OF
No.
DNDI NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A501
DOOR SCHEDULE
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
SCALE: 1/4" = 1'-0"
DOOR TYPES
SCALE: 1/4" = 1'-0"
DOOR FRAME ELEVATIONS
DOOR SCHEDULE
OPENING #ROOM NAME
DOOR FRAME DETAILS LABEL
HDWR SETREMARKSWIDTHHEIGHTTHICKNESSMATERIALELEVATIONFINISHGLAZINGMATERIALELEVATIONFINISHHEADJAMBSILLFIRE RATINGFIRST FLOOR
101 STORAGE UNITS 3' - 0" 7' - 0" 1 3/4" HM D2 PT F1 PT H2 J2 - 10
102 BREAKROOM 3' - 0" 7' - 0" 1 3/4" HM D2 PT F1 PT H2 J2 - 3
103 TELECOM 3' - 0" 7' - 0" 1 3/4" HM D2 PT F1 PT H2 J2 - 3
104 JANITOR 3' - 0" 7' - 0" 1 3/4" HM D2 PT F1 PT H2 J2 - 3
105 WC 3' - 0" 7' - 0" 1 3/4" HM D2 PT F1 PT H2 J2 - 9
108 STAIR 3' - 0" 7' - 0" 1 3/4" HM D2 PT F2 PT H3 J3 90 MIN. 6
111 STAIR 3' - 0" 7' - 0" 1 3/4" HM D2 PT F2 PT H3 J2 90 MIN. 6
112 VESTIBULE 12' - 0" 7' - 0" 1 1/4" AL CA IGL-1 AL 2.2 REMARK 1
EX101A OFFICE 3' - 0" 7' - 10" 1 3/4" AL D1 CA IGL-1 S3 CA - 5
EX101B OFFICE 3' - 0" 7' - 10" 1 3/4" AL D1 CA IGL-1 S3 CA - 5
EX106 ELEC. 3' - 0" 7' - 0" 1 3/4" IHM D2 PT F1 PT 45 MIN. 7
EX107 SPRINKLER 3' - 0" 7' - 0" 1 3/4" IHM D2 PT F1 PT - 7
EX108 STAIR 3' - 0" 7' - 0" 1 3/4" IHM D2 PT F2 PT 90 MIN. 1
EX110 CORRIDOR 12' - 0" 7' - 0" 1 1/4" AL CA IGL-1 AL 2.2 REMARK 1
EX111 STAIR 3' - 0" 7' - 0" 1 3/4" HM D2 PT F2 PT 90 MIN. 1
EX112 VESTIBULE 12' - 0" 7' - 0" 1 1/4" AL CA IGL-1 AL 2.2 REMARK 1
SECOND FLOOR
201 STAIR 3' - 0" 7' - 0" 1 3/4" HM D2 PT F2 PT H3 90 MIN. 6
203 STAIR 3' - 0" 7' - 0" 1 3/4" HM D2 PT F2 PT H3 90 MIN. 6
THIRD FLOOR
301 STAIR 3' - 0" 7' - 0" 1 3/4" HM D2 PT F2 PT H3 90 MIN. 6
303 STAIR 3' - 0" 7' - 0" 1 3/4" HM D2 PT F2 PT H3 90 MIN. 6
SCALE: 3" = 1'-0"H1HEAD DETAIL
SCALE: 3" = 1'-0"J1 JAMB DETAIL
SCALE: 3" = 1'-0" H2HEAD DETAIL
SCALE: 3" = 1'-0" J2JAMB DETAIL
SCALE: 3" = 1'-0" H3HEAD DETAIL
SCALE: 3" = 1'-0"J3 JAMB DETAIL
#DESCRIPTION DATE
1 BID ADDEN. 001 10/13/2020
1
1
1
1
07/14/21
SEALANT JOINT AT
FRAME PERIMETER TYP.
CFMF HEADER. DESIGN
PER OPENING WIDTH
MESH WEEP/VENT [04 00 00-D4]
COPPER -LAMINATED
THROUGH-WALL FLASHING WITH
STAINLESS STEEL DRIP EDGE. HEM
EXPOSED EDGE [04 00 00-D2]
CAVITY DRAINAGE MATERIAL [04
00 00-D5]
FLASHING TERMINATION BAR [04
00 00-D3]
STEEL LINTEL. REFER STRUCT.
LINTEL SCHEDULE
5/8" 6" 1/2" 3 7/8" 3 5/8"
CONTINUE FLUID-APPLIED
AIR BARRIER INTO FRAMED
OPENING
REFER TO ELEVATIONS FOR MASONRY
HEADER CONDITION - LIMESTONE,
SOLDIER OR BAND COURSE
STOREFRONT SYSTEM, THERMALLY
BROKEN, FRONT GLAZED [08 41
00-A1]
7 1/8" 4 1/2" 3"
2x4 2x4
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
INSULATION TYPE 4 - KRAFT FACED
FIBERGLASS BATT INSULATION, R19
MIN. [07 21 00-A4]
6" METAL STUD [05 41 00-A4]
1/2" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A1]
FLUID-APPLIED MEMBRANE AIR
BARRIER SHOWN DASHED [07 27
26-A1]
[04 21 13-A1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
SEALANT JOINT AT
FRAME PERIMETER TYP.
MESH WEEP/VENT [04 00 00-D4]
COPPER-LAMINATED
THROUGH-WALL FLASHING WITH
STAINLESS STEEL DRIP EDGE. HEM
EXPOSED EDGE [04 00 00-D2]
CAVITY DRAINAGE MATERIAL [04
00 00-D5]
FLASHING TERMINATION BAR [04
00 00-D3]
STEEL LINTEL. REFER STRUCT.
LINTEL SCHEDULE
CONTINUE FLUID-APPLIED
AIR BARRIER INTO FRAMED
OPENING
REFER TO ELEVATIONS FOR
MASONRY HEADER
CONDITION - SOLDIER OR
BAND COURSE.
QUEEN BRICK - 3/8" JOINT [04 20
00-A3]
[04 20 00-E1]
1 1/2"
2x4 2x4
7 5/8" 4 3/4" 3 5/8"
STOREFRONT SYSTEM, THERMALLY
BROKEN, FRONT GLAZED [08 41
00-A1]
FLUID-APPLIED MEMBRANE AIR
BARRIER SHOWN DASHED [07 27
26-A1]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
AIR SPACE [04 00 00-D7]
[04 21 13-A1]
8 1/2" 3 7/8" 5/8"
STRUCTRUAL STEEL BEAM.
REFER TO STRUCTRUAL DRAWINGS
[04 20 00-E1]
[06 2023-01]
[04 21 13-A1]
STOREFRONT SYSTEM, THERMALLY
BROKEN, FRONT GLAZED [08 41
00-A1]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
INSULATION TYPE 4 - KRAFT FACED
FIBERGLASS BATT INSULATION, R19
MIN. [07 21 00-A4]
GLAZING - REFER TO
ELEVATION FOR TYPE.
SOLID SURFACE WINDOW SILL -
REFER TO FINISH PLAN (123662) [12
36 62-A1]5/8"6" 8" CONTINUE SELF ADHERING SHEET AIR
BARRIER INTO FRAMED OPENING
2x4
2x4 7 1/8"4 1/2" 3" 1/2" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A1]
AIR SPACE [04 00 00-D7]
SCREW-ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]3" 4 1/2" 8 1/2"CONTINUE SELF ADHERING SHEET AIR
BARRIER INTO FRAMED OPENING
QUEEN BRICK - 3/8" JOINT [04 20
00-A3]
SOLID SURFACE WINDOW SILL -
REFER TO FINISH PLAN (123662) [12
36 62-A1]
STOREFRONT SYSTEM, THERMALLY
BROKEN, FRONT GLAZED [08 41
00-A1]
GLAZING - REFER TO
ELEVATION FOR TYPE.1' - 4"1 1/2"2x4
2x4
SOLID SOLDIER WITH 3/8" JOINT
[04 20 00-B4]
FLUID-APPLIED MEMBRANE AIR
BARRIER SHOWN DASHED [07 27
26-A1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
[06 2023-01]
[04 00 00-C11]
SEALANT JOINT AT
FRAME PERIMETER TYP.
FLUID-APPLIED MEMBRANE AIR
BARRIER SHOWN DASHED [07 27
26-A1]
CONTINUE SELF ADHERING SHEET AIR
BARRIER INTO FRAMED OPENING
1/2"
[04 21 13 -A1]
SOLID SURFACE WINDOW SILL -
REFER TO FINISH PLAN (123662) [12
36 62-A1]2"3 1/2" 2x42x4
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
STOREFRONT SYSTEM, THERMALLY
BROKEN, FRONT GLAZED [08 41
00-A1]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
INSULATION TYPE 4 - KRAFT FACED
FIBERGLASS BATT INSULATION, R19
MIN. [07 21 00-A4]
6" METAL STUD [05 41 00-A4]
5/8" 6" 1/2" 3 7/8" 3 5/8"
7 1/8" 4 1/2" 3"
AIR SPACE [04 00 00 -D7]
1/2" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A1]
[04 21 13 -B2]
GLAZING - REFER TO ELEVATION
FOR TYPE
SILL FLASHING
SELF ADHERING SHEET AIR BARRIER
SHOWN DASHED [07 27 13-A1]
WRAP AROUND BLOCKING
SEALANT JOINT AT
FRAME PERIMETER TYP.
FLUID-APPLIED MEMBRANE AIR
BARRIER SHOWN DASHED [07 27
26-A1]
CONTINUE SELF ADHERING SHEET AIR
BARRIER INTO FRAMED OPENING
1/2"3 1/2"[04 21 13 -A1]
7 1/8" 4 1/2" 3"
SOLID SURFACE WINDOW SILL -
REFER TO FINISH PLAN (123662) [12
36 62-A1]
STOREFRONT SYSTEM, THERMALLY
BROKEN, FRONT GLAZED [08 41
00-A1]
2x4 2x4
7 5/8" 4 3/4" 3 5/8"
SOLID BRICK SILL [04 20 00-B2]
QUEEN BRICK - 3/8" JOINT [04 20
00-A3]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
[04 21 13-B2]
SILL FLASHING
AIR SPACE [04 00 00-D7]
SELF ADHERING SHEET AIR BARRIER
SHOWN DASHED [07 27 13-A1]
WRAP AROUND BLOCKING
PRE FINISHED ALUM.
DOOR
ALUM. THRESHOLD
SET IN BED OF SEALANT
EXPANSION JOINT
FLOOR FINISH - SEE FLOOR
FINISH
CONCRETE SLAB /
FOUNDATION - REFER
STRUCTURAL DWG'S
EXTERIOR
EXTERIOR PAVING - REFER
LANDSCAPE / CIVIL
DWG'S
REFER TO ELEVATIONS FOR
GLAZING TYPE
INTERIOR
[04 21 13-A1]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
INSULATION TYPE 4 - KRAFT FACED
FIBERGLASS BATT INSULATION, R19
MIN. [07 21 00-A4]
FLUID-APPLIED MEMBRANE AIR
BARRIER SHOWN DASHED [07 27
26-A1] 5/8"6" 8" CONTINUE FLUID-APPLIED
AIR BARRIER INTO FRAMED
OPENING
2x4
2x4
6"3" SEALANT AT PERIMETER TYP.
HOLLOW METAL DOOR
FRAME - REFER SCHEDULE
HM JAMB ANCHOR
HOLLOW METAL FRAME -
REFER SCHEDULE
SEALANT JOINT AT FRAME
PERIMETER TYP.
METAL STUD HEADER. SIZE
PER OPENING WIDTH
5 5/8" 6" 3"
MESH WEEP/VENT [04 00 00-D4]COPPER-LAMINATED
THROUGH-WALL FLASHING WITH
STAINLESS STEEL DRIP EDGE. HEM
EXPOSED EDGE [04 00 00-D2]
CAVITY DRAINAGE MATERIAL [04
00 00-D5]
FLASHING TERMINATION BAR [04
00 00-D3]
FLUID-APPLIED MEMBRANE AIR
BARRIER SHOWN DASHED [07 27
26-A1]
STEEL LINTEL. REFER STRUCT.
LINTEL SCHEDULE
5/8" 6" 1/2" 7 1/2"DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A502
EXTERIOR DOOR AND
STOREFRONT DETAILS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
SCALE: 3" = 1'-0"03STOREFRONT EXTERIOR -HEAD DETAIL BRICK
SCALE: 3" = 1'-0"06STOREFRONT EXTERIOR -HEAD DETAIL CMU
SCALE: 3" = 1'-0"02STOREFRONT EXTERIOR -JAMB DETAIL BRICK
SCALE: 3" = 1'-0" 05 STOREFRONT EXTERIOR -JAMB DETAIL CMU
SCALE: 3" = 1'-0" 01STOREFRONT EXTERIOR -SILL DETAIL BRICK
SCALE: 3" = 1'-0"04STOREFRONT EXTERIOR -SILL DETAIL CMU
#DESCRIPTION DATE
SCALE: 3" = 1'-0"07STOREFRONT EXTERIOR -SILL DETAIL
SCALE: 3" = 1'-0"08HM DOOR JAMB DETAIL BRICK
SCALE: 3" = 1'-0" 09HM HEAD DEATIL BRICK
07/14/21
GENERAL WINDOW & STOREFRONT NOTES
A. REFER TO WALL SECTIONS AND PLAN DETAILS AND WINDOW DETAILS FOR FULL
SCOPE OF WINDOWS AND STOREFRONTS.
B. REFER TO PLAN DRAWINGS FOR WINDOW LOCATIONS.
C. REFER TO SPECIFICATIONS FOR FULL DESCRIPTION OF GLAZING TYPES. GLAZING
LEGEND ON DRAWINGS IS ABBREVIATED.
D. COORDINATE WINDOW TYPE DRAWINGS AND ROUGH OPENINGS WITH WALL
FRAMING DRAWINGS.
E. REFER TO STANDARD DETAILS FOR PROPER INSTALLATION.
F. STOREFRONTS DETAILED ON THIS SHEET ARE BASED ON KAWNEER TRI-FAB VG 451T
UNLESS NOTED OTHERWISE.
1/4" FULLY TEMPERED CLEAR FLOAT GLASSGL-1
**REFER TO PROJECT MANUAL FOR COMPLETE GLAZING SPECIFICATION.
**CONTRACTOR TO PROVIDE FULLY TEMPERED LITES IN ALL LOCATIONS
REQUIRED BY CODE INCLUDING BATHROOMS AND WITHIN 30" OF FLOOR
GLAZING SCHEDULE
1" CLEAR INSULATING GLASS WITH LOW-E COATING, FULLY TEMPEREDIGL-1
IGL-2 1" SPANDREL INSULATING GLASS, FULLY TEMPERED
2" 3' - 8 1/4" 2" EQ 2" EQ 2" EQ 2"
15' - 9"2" 7' - 8" 2"8' - 0"1st FLOOR
UPPER FLOOR IGL-2
1st FLOOR
UPPER FLOOR IGL-2
1st FLOOR
UPPER FLOOR IGL-2
1st FLOOR
UPPER FLOOR IGL-2
IGL-1IGL-1IGL-1IGL-1
EQ2"EQ2"EQ2"EQ
2" 7' - 8" 2"16' - 0"8' - 0"1st FLOOR
UPPER FLOOR IGL-2
1st FLOOR
UPPER FLOOR IGL-2
1st FLOOR
UPPER FLOOR IGL-2
1st FLOOR
UPPER FLOOR IGL-2
IGL-1IGL-1IGL-1IGL-1
5' - 5 5/8"2"3' - 0" 2" 7' - 8" 2"8' - 0"IGL-1
2"EQ 2" EQ 2"EQ2" EQ 2"2" EQ2"EQ2"EQ2"EQ2"2"7' - 8"2"8' - 0"25' - 9 3/4"
IGL-1 IGL-1 IGL-1 IGL-1 IGL-1 IGL-1 IGL-1 IGL-11st FLOOR
UPPER FLOOR IGL-2
1st FLOOR
UPPER FLOOR IGL-2
1st FLOOR
UPPER FLOOR IGL-2
1st FLOOR
UPPER FLOOR IGL-2
1st FLOOR
UPPER FLOOR IGL-2
1st FLOOR
UPPER FLOOR IGL-2
1st FLOOR
UPPER FLOOR IGL-2
1st FLOOR
UPPER FLOOR IGL-2
01
A307
3' - 9 3/4" EQ 3' - 8 3/4" EQ 3' - 8 3/4"EQ 3' - 8 3/4" EQ 3' - 8 3/4" EQ 3' - 8 3/4" EQ 3' - 8 3/4" EQ 3' - 8 3/4" EQ 3' - 8 3/4" EQ 3' - 8 3/4" EQ 3' - 5 1/4"
42' - 9 3/4"2"7' - 8" 2"8' - 0"4 1/2"
IGL-1 IGL-1 IGL-1 IGL-1 IGL-1 IGL-1 IGL-1 IGL-1 IGL-1IGL-1 IGL-1
DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DNDI NAA AII
R E G I STERE
DNDI NA AI
HI TARC TECDANDRID GE DREW
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A503
WINDOW AND
STOREFRONT ELEVATIONS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
S1S2 S3
S4
S5
WINDOW AND STOREFRONT ELEVATIONS
SCALE: 1/2" = 1'-0"
EXTERIOR ALUMINUM STOREFRONT SYSTEM EXTERIOR ALUMINUM STOREFRONT SYSTEM EXTERIOR ALUMINUM STOREFRONT SYSTEM
EXTERIOR ALUMINUM STOREFRONT SYSTEM
EXTERIOR ALUMINUM STOREFRONT SYSTEM
#DESCRIPTION DATE
07/14/21
MILLWORK LEGEND
XX"
XX"
XX"
EXTRA SHELF
300MCABINET WIDTH CABINET HEIGHT
FEATURE
DESCRIPTION
CABINET DEPTH
CABINET TYPE
CABINET TAG
A. MILLWORK IS BASED ON AWI ARCHITECTURAL WOODWORK STANDARDS 2009
EDITION.
B. DESIGN DRAWINGS ARE BASED ON CDS (CABINET DESIGN SERIES) NUMBERS.
REFER TO CABINET TAG BELOW FOR DESCRIPTION.
C. REFER TO TYPICAL CASEWORK DETAILS ON THIS SHEET FOR PROJECT SPECIFIC
CONSTRUCTION REQUIREMENTS. THESE MAY BE DEVIATIONS FROM AWI
STANDARD.
D. REFER TO PROJECT MANUAL/SPECIFICATIONS FOR ADDITIONAL INFORMATION
ON PLASTIC LAMINATE AND STAINLESS STEEL CABINETS.
E. IF DRAWINGS OR SPECIFICATIONS ARE IN CONFLICT, PROVIDE MORE STRICT OR
MORE EXPENSIVE OPTION.
A. REFER TO A201 FOR EXTERIOR MATERIAL SCHEDULE.
B. REFER TO A505 FOR WINDOW/STOREFRONT ELEVATIONS.
C. PAINT ALL EXPOSED MISC. STEEL LINTELS, PLATES, ANGLES, ETC. PX UNLESS NOTED
OTHERWISE.
D. ALL BASE TO BE B1 UNLESS NOTED OTHERWISE.
E. COORDINATE AND PROVIDE BACKING FOR MILLWORK AND ITEMS ATTACHED
OR MOUNTED TO WALLS AND CEILINGS.
F. ALL RESTROOM ACCESSORIES WILL BE NEW.
G. PROVIDE FILLERS AS REQUIRED. FILLERS ARE TO MACH MILLWORK ADJACENT.
H. ALL WALLS TO BE PAINTED P1 UNLESS NOTED OTHERWISE.
GENERAL INTERIOR ELEVATION NOTES
4
2
T3
T2
4
1
2
3
T4
T5 T2
T3
T1
T2
4
1
T5
T4
T1
1' - 8" 1' - 8" 3' - 4"1' - 8" 1' - 8" 2"
15' - 11 1/2"2' - 10" 2' - 10" 2" 3' - 4" 3' - 4" 3' - 4"
5
6
7
8
9
6
8
10
5' - 9 1/2" 3' - 4"5' - 9 1/2"9' - 0"10' - 2"4" 1' - 8" 2" 8"9"DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A601
INTERIOR ELEVATIONS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
INTERIOR ELEVATION KEYNOTES
1 WALL HUNG SINK - ADA COMPLIANT. REFER TO PLUMBING DWGS.
2 FLOOR MOUNTED PLUMBING FIXTURE. REFER TO PLUMBING DWGS.
3 STAINLESS STEEL TERMINATION CAP.
4 GYPSUM BOARD - PAINT.
5 PLASTIC LAMINATE TOE KICK - PL1
6 PLASTIC LAMINATE FILLER STRIP - TYPICAL AT EACH SIDE OF UPPER AND LOWER
CABNETS.
7 PLASTIC LAMINATE BASE CABINETS - PL1.
8 CABINETS HARDWARE
9 PLASTIC LAMINATE COUNTERTOP AND BACKSPLASH - PL2
10 SINK - ADA COMPLIANT. REFER TO PLUMBING DWGS.
1
2
3
4
5
6
7
SCALE:
ELEVATION
1/2" = 1'-0" 01 RESTROOM EAST WALL
SCALE:
ELEVATION
1/2" = 1'-0" 02RESTROOM NORTH WALL
SCALE:
ELEVATION
1/2" = 1'-0"03 RESTROOM WEST WALL
SCALE:
ELEVATION
1/2" = 1'-0"04BREAKROOM NORTH WALL
#DESCRIPTION DATE
07/14/21
A.PROVIDE FINISH SAMPLE SUBMITTALS FOR ALL FINISH ITEMS FOR ARCHITECT
APPROVAL PRIOR TO INSTALLATION.
B.LEVEL ALL FLOORS IN ACCORDANCE WITH FLOORING FINISH MANUFACTURERS
SPECIFICATIONS.
C.ALL PAINT FINISH LOCATIONS TO BE THREE-COAT SYSTEM. REFER TO
SPECIFICATIONS FOR PREPARATION, SYSTEM DESCRIPTION AND PRODUCTS.
D.WHERE DISSIMILAR FLOORING FINISHES MEET, THEY MUST DO SO UNDER
CENTERLINE OF DOOR UNLESS NOTED OTHERWISE. REFER TO SPECIFICATIONS
AND TO 2/A702 FOR TRANSITION STRIPS.
F. ALL EXPOSED STRUCTURAL STEEL COLUMNS, BEAMS, BRACING, JOISTS ETC. IS
TO BE FACTORY PRIMED.
G. ALL HOLLOW DOORS AND METAL DOOR FRAMES TO BE PAINTED P1, UNLESS
OTHERWISE NOTED
XX
FLOORING DIRECTION
XX
WALL FINISH TAG
(DENOTES DIFFERENT WALL FINISH LOCATION)
ARROWS INDICATES EXTENT OF FINISH
INDICATES FINISH MATERIAL
MATERIAL TRANSITION
(DENOTES DIFFERENT MATERIAL TRANSITION LOCATIONS)
INDICATES FINISH MATERIAL
X INDICATES FINISH MATERIAL
INDICATES MATERIAL DIRECTION
ROOM TAG
ROOM NAME
ROOM NUMBER
WALL FINISH
BASE FINISH
FLOOR FINISH
REMARKS
GENERAL FINISH NOTES
GENERAL FINISH SYMBOLS
Room
Name
XXXXX
Floor
Wall
Base
-
-
-
FINISH SCHEDULE REMARKS
1.CMU BLOCK WALLS OF STAIR AND ELEVATOR ARE THE ONLY SURFACES TO RECEIVE
PAINT IN THESE AREAS, TYPICAL, UNLESS OTHERWISE NOTED.
CONCRETE
CONC 1 TYPE: HARD TROWEL FINISH. PROVIDE HARDENER
FOLLOWING INITIAL SET PERIOD.
ONLY PUBLIC AREAS, HALLWAYS, STAIRS, ETC.
TO RECEIVE FINAL FINSH SEALER. EXCLUDE
SEALER IN AREAS DESIGNATED AS STORAGE
UNITS.
RF1 MFG:
STYLE:
COLOR:
INSTALLATION:
PATCRAFT - LUXURY VINYL TILE
NORTHBRIDGE
02500 RELIC ASH
6"X36"
RESILIENT FLOORING
WB1 MFG:
STYLE:
COLOR:
HEIGHT:
PATCRAFT
WALL BASE S127V
00550
4"
WALL BASE
PT1 MFG:
COLOR:
TYPE:
SHERWIN WILLIAMS
SW7049 NUANCE
EGGSHELL WALLS, SEMI-GLOSS TRIM
INTERIOR LATEX
PAINT
PT2 MFG:
COLOR:
TYPE:
SHERWIN WILLIAMS
BRIGHT WHITE
SEMI-GLOSS
A. BLOCK FILLER: LOXON BLOCK
SURFACER, A24W200
B. INTERMEDIATE COAT: PRO INDUSTRIAL
PRE-CATALYZED WATERBASED EPOXY,
K46 SERIES
C. TOP COAT: PRO INDUSTRIAL PRE-
CATALYZED WATERBASED EPOXY, K46
SERIES
PL1 MFG:
PATTERN:
TEXTURE:
PIONITE
CUBICAL PAPEL AG561
SUEDE
PLASTIC LAMINATE
PL2 MFG:
PATTERN:
TEXTURE:
WILSONART
SKYLINE WALNUT 7946K-12
N/A
FINISH MATERIALS LEGEND
PT3 MFG:
COLOR:
TYPE:
SHERWIN WILLIAMS
BRIGHT WHITE
SEMI-GLOSS
A. PRIME COAT: PRO-INDUSTRIAL PRO-
CRYL UNIVERAL PRIMER, B66-310 SERIES
B. INTERMEDIATE COAT: PRO INDUSTRIAL
WATER BORNE ACRYLIC DRYFALL,
B42-80 SERIES
C. TOP COAT: PRO INDUSTRIAL WATER
BORNE ACRYLIC DRYFALL, B42-80
SERIES
DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
GSD
08.17.2020
A700
FINISH SCHEDULES AND
SPECIFICATIONS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
#DESCRIPTION DATE
07/14/21
M001
MECHANICAL SPECIFICATIONS
GENERAL
1. BID INSTRUCTIONS: CONTRACTORS SHALL PROVIDE
BASE BID IN STRICT ACCORDANCE WITH DESIGN
BASIS EQUIPMENT AND MATERIALS. PROJECT DOES
ENCOURAGE COMPETITIVE PRICING AND ALLOWS
FOR SUBSTITUTIONS OF EQUAL EQUIPMENT AND
MATERIALS AGAINST THE BASIS OF DESIGN.
SUBSTITUTE ITEMS WILL BE COMPARED AGAINST
DESIGN BASIS DURING SUBMITTAL PROCESS.
ENGINEER RESERVES THE RIGHT TO REJECT
SUBSTITUTIONS FOUND NOT TO BE EQUAL TO ITEMS
LISTED IN DESIGN BASIS.
2. PRIOR TO PROCUREMENT CONTRACTOR SHALL
SUBMIT TO ARCHITECT FULL SUBMITTALS FOR ALL
ENERGY CONSUMING OR PRODUCING ITEMS AND
FOR ALL DUCT ACCESSORIES, INSULATION, VAV
BOXES, REGISTERS, GRILLES, DIFFUSERS AND
LOUVERS. SUBMITTALS SHALL BE DELINEATED WITH
TAGS INDICATED ON PRINTS, CONTRACTORS NAME,
PROJECT NAME. CLEARLY INDICATE ALL MODEL
NUMBERS AND ALL ACCESSORIES AND OPTIONS
BEING PROVIDED. SUBMISSIONS SHALL BE IN PDF
FORMAT. ALL EQUIPMENT AND ITEMS SHALL BE PER
DESIGN BASIS OR APPROVED EQUAL. ENGINEER
RESERVES THE RIGHT TO REJECT ANY SUBSTITUTE
ITEM.
3. CONTRACTOR SHALL BE RESPONSIBLE TO
COORDINATE ALL REQUIRED ELECTRICAL SUPPORT
NEEDED FROM THE ELECTRICAL CONTRACTOR.
ENSURE ALL SUBMITTALS FOR POWERED
COMPONENTS AND CONTROLS ARE PROVIDED AND
FULLY COORDINATED WITH ELECTRICAL
CONTRACTORS.
4. CONTRACTOR SHALL BE RESPONSIBLE TO VISIT THE
SITE TO EXAMINE ALL CONDITIONS THAT MAY IN ANY
WAY AFFECT THE EXECUTION OF HIS WORK. HE
SHALL ALSO EXAMINE THE DRAWINGS AND
SPECIFICATIONS FOR OTHER BRANCHES OF WORK
MAKING REFERENCE TO THEM FOR DETAILS OF
EXISTING BUILDING CONDITIONS. NO EXTRAS WILL
BE ALLOWED FOR FAILURE TO INCLUDE ALL
REQUIRED WORK IN THE BID. CONTRACTOR SHALL
GUARANTEE ALL LABOR AND MATERIALS ENTERING
INTO CONTRACT FOR A PERIOD OF ONE (1) YEAR
FROM DATE OF ACCEPTANCE.
5. THE DRAWINGS IN THIS SECTION ARE
DIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE
EXACT QUANTITIES, LOCATIONS OR CODIFIED
REQUIREMENTS. DRAWINGS SHOW GENERAL
INTENT OF SYSTEMS. M.C. SHALL PROVIDE AND PAY
FOR ALL REQUIRED PERMITS.
6. PRIOR TO WORK COORDINATE ALL OPENINGS AND
INSTALLATIONS OF DUCT, PIPING, EQUIPMENT,
CONTROLS, DIFFUSERS AND GRILLES WITH G.C. AND
OTHER TRADES. PROVIDE INSTALLATIONS WITH
PROPER MANUFACTURERS RECOMMENDED
CLEARANCES.
7. UPON COMPLETION OF THE MECHANICAL
INSTALLATION, DEMONSTRATE TO THE ENGINEER
AND THE OWNER'S SATISFACTION THAT THE
SYSTEMS HAVE BEEN INSTALLED IN ACCORDANCE
WITH THE DRAWINGS, SPECIFICATIONS AND
APPLICABLE CODES. DEMONSTRATE THE DYNAMIC
OPERATION OF EACH SYSTEM. VERIFY PROPER
OPERATION OF EQUIPMENT, FILTERS ARE CLEAN
AND COMPONENTS OF THE SYSTEM ARE INSTALLED
AND ADJUSTED IN FULL ACCORDANCE WITH
MANUFACTURER RECOMMENDATIONS.
8. ALL WORK SHALL BE IN FULL ACCORDANCE WITH
2014 INDIANA MECHANICAL CODE (2012
INTERNATIONAL MECHANICAL CODE), INDIANA
ENERGY CODE (ASHRAE 90.1-2007) PERTINENT
STATE, COUNTY, CITY CODES AND ORDINANCES AND
INDIANA AMENDMENTS.
9. MECHANICAL CONTRACTOR SHALL ENSURE
EMPLOYEES ARE MEETING AND DOCUMENTING ALL
OSHA AND JOB SPECIFIC SAFETY REQUIREMENTS AS
REQUIRED BY LAW AND BY CONTRACT. PERSONAL
PROTECTIVE EQUIPMENT SHALL BE PROVIDED AND
UTILIZED AS REQUIRED. MECHANICAL CONTRACTOR
SHALL PAY ALL FINES LEVIED BY OSHA FOR FAILURE
TO COMPLY WITH OSHA REQUIREMENTS.
10. INSTALL ALL EQUIPMENT, DUCTWORK AND PIPING AS
HIGH AS POSSIBLE. PRIOR TO ROUGH-IN
COORDINATE ELEVATIONS WITH OTHER TRADES.
WHERE VISIBLE, ORIENT PERPENDICULAR AND/OR
PARALLEL TO STRUCTURE.
EQUIPMENT
1. PROVIDE EQUIPMENT AS SHOWN ON EQUIPMENT
SCHEDULES AND PLAN NOTES. SUBSTITUTIONS TO
LISTED EQUIPMENT SHALL BE AT RISK OF
CONTRACTOR. SUBSTITUTIONS SHALL ONLY BE
ALLOWED IF ITEMS ARE EQUAL IN ALL ASPECTS.
2. PROVIDE SUBMITTALS TO ELECTRICIAN AS
REQUIRED FOR COORDINATION OF ALL ELECTRICAL
POWER WIRING. INCLUDE WIRING DIAGRAMS AND
CABLING REQUIREMENTS FOR REFERENCE.
COORDINATE ALL INTERLOCKS AS NEEDED. PROVIDE
SINGLE POINT CONNECTION KITS AS NEEDED.
3. INSTALL ALL EQUIPMENT IN FULL ACCORDANCE
WITH MANUFACTURERS RECOMMENDATIONS AND
CLEARANCE REQUIREMENTS. PROVIDE ALL
REQUIRED MOUNTING OR HOUSEKEEPING PADS.
G.C. SHALL PROVIDE LEVEL GRADE FOR EXTERIOR
MOUNTED EQUIPMENT. M.C. SHALL PROVIDE ALL
HOISTING AND RIGGING NEEDED TO SET ALL HVAC
EQUIPMENT.
4. ALL EQUIPMENT SHALL BE INSTALLED AS NEEDED
TO PREVENT OBJECTIONABLE NOISE AND/OR
VIBRATION. M.C. SHALL PROVIDE VIBRATION PADS,
SPRING ISOLATORS, ATTENUATORS AND
ACCESSORIES AS NEEDED.
DUCTWORK
1. CONCEALED ROUND DUCTWORK SHALL BE
CONSTRUCTED PER SMACNA LOW PRESSURE
STANDARDS 1" PRESSURE CLASS, 5' MAXIMUM JOINT
LENGTHS, SEAL CLASS B LONGITUDINAL SEAM SNAP
LOCK PIPE AND ADJUSTABLE FITTINGS.
2. EXPOSED ROUND DUCTWORK (OR WHERE SPIRAL IS
INDICATED ON THE PLANS) SHALL BE LINDAB OR
EQUAL GALVANIZED STEEL CONFORMING TO ASTM
STANDARDS A653 AND A924 GASKETED SPIRAL
DUCTING WITH NO SEALER. EDPM RUBBER GASKET
SHALL BE U.L. CLASSIFIED RATING OF FLAME
SPREAD 0 AND SMOKE DEVELOPED 5 IN
ACCORDANCE WITH ASTM STANDARD E84-91A
SMACNA LEAKAGE CLASS 3. FITTINGS SHALL BE
MANUFACTURED USING ONE OR MORE OF THE
FOLLOWING CONSTRUCTION METHODS:
OVERLAPPED EDGES STITCH WELDED ALONG THE
ENTIRE LENGTH OF THE FITTING, STANDING SEAM
GORE LOCKED AND INTERNALLY SEALED, BUTTON
PUNCHED AND INTERNALLY SEALED. ELBOWS 3-INCH
THROUGH 12-INCH DIAMETER WILL BE DIE STAMPED
AND CONTINUOUSLY STITCH WELDED.
2. PROVIDE SHEET METAL 90 FOR ALL TURNS GREATER
THAN 45 DEGREES. DO NOT USE FLEXIBLE DUCT
FOR CHANGES IN DIRECTION GREATER THAN 45
DEGREES.
3. PROVIDE MANUAL BALANCING DAMPERS FOR ALL
SUPPLY AIR RUNS. ROUND DAMPERS SHALL BE
SECURED ON BOTH SIDES OF DUCT AND SHALL
CONTAIN LOCKING HANDLE. SPIRAL DUCTS SHALL
USE SPIRAL STYLE DAMPERS WITH FULL WIDTH
SHAFTS AND NYLON BEARINGS AT EACH END.
RECTANGULAR DUCTS SHALL USE MULTI OR SINGLE
BLADE WELDED FRAMED DAMPERS WITH JACK
SHAFTS AND LOCKING HANDLE. INSTALL NYLON
RIBBON ON ALL DAMPER HANDLES LOCATED IN
INSULATED DUCTING. DO NOT INSTALL DAMPERS IN
NON ACCESSIBLE LOCATIONS. PROVIDE INTEGRAL
DAMPERS WITH DIFFUSER IN NECK IF NO
ACCESSIBLE LOCATION IS POSSIBLE. ALL SUPPLY
AIR RUNS SHALL HAVE MEANS OF BALANCE. RETURN
AND EXHAUST AIR RUNS SHALL CONTAIN DAMPERS
WHERE SHOWN ON PLANS.
4. INSULATED FLEXIBLE DUCTING SHALL NOT EXCEED
25 FEET. ALL FLEX SHALL BE LISTED FLEXIBLE DUCT,
FLEXIBLE CONNECTORS ARE NOT ACCEPTABLE.
FLEXIBLE DUCT EQUAL TO FLEXIBLE DUCT CLASS 1
AIR DUCT, DOUBLE LAMINATED POLYESTER FILM ON
STEEL WIRE REINFORCING, INSULATED WITH SCRIM
REINFORCED METALIZED POLYESTER OUTER FIRE
RETARDANT JACKET. R-4.2 FOR CONDITIONED
SPACES AND R-6.0 FOR ANY SPACES OUTSIDE
BUILDING THERMAL ENVELOPE. FLEX DUCTS SHALL
NOT BE RUN THROUGH WALLS OR FLOORS. PROVIDE
HARD DUCTED SLEEVES AS NEEDED.
5. RECTANGULAR DUCTWORK SHALL BE
CONSTRUCTED IN ACCORDANCE WITH SMACNA LOW
PRESSURE DUCT STANDARDS, +/- 1.0" W.C. FROM
ASTM A 653/A 653M G-90 COATED GALVANIZED
SHEET STEEL. SEAMS SHALL BE PITTSBURGH
CONSTRUCTION, NO BUTTON PUNCH OR SNAP LOCK
SEAMS ARE ACCEPTABLE. SEAL ALL TRANSVERSE
AND LONGITUDINAL SEAMS WITH WATER BASED
DUCT SEALER, SEAL CLASS B. GAUGE AND JOINT
CLASSIFICATIONS ACCEPTABLE ARE AS FOLLOWS,
ALL SECTION LENGTHS ARE 48" MAXIMUM, REFER TO
SMACNA RIGIDITY TABLES FOR GAUGES ON LONGER
SECTIONS IF REQUIRED:
< 12" 26 GAUGE, FLAT S AND DRIVE
12"-24" 24 GAUGE, FLAT S AND DRIVE
25"-34" 22 GAUGE, STANDING S AND FLAT
DRIVE
34"-40" 22 GAUGE, STANDING S AND STANDING
DRIVE
>40" REFER TO SMACNA FOR STANDARDS.
6. DUCT HANGERS: COMPLY WITH SMACNA'S "HVAC
DUCT CONSTRUCTION STANDARDS - METAL AND
FLEXIBLE," CHAPTER 5, "HANGERS AND SUPPORTS."
PROVIDE GALVANIZED MINIMUM 22 GAUGE 1" WIDE
STRAP TO HANG RECTANGULAR DUCTWORK
SMALLER THAN 30" WIDE. DUCT HANGERS FOR
RECTANGULAR SHEET METAL DUCTS 30" AND
LARGER SHALL BE TRAPEZE STYLE USING
UNI-STRUT AND 3/8" OR 1/2" ROD. PROVIDE GRIPPLE,
DURODYNE OR EQUAL CABLE HANGERS FOR
HANGING ROUND DUCTWORK. SUPPORT ALL
HANGERS FROM STRUCTURE PER SMACNA
STANDARDS.HANGERS FOR SPIRAL DUCTS GREATER
THAN 28" IN DIAMETER SHALL BE HUNG WITH ROD
AND DUCT CLAMP. FLEXIBLE DUCTING SHALL BE
SUPPORTED USING MINIMUM 2" WIDE NYLON STRAP.
ALL INTERVALS ARE PER SMACNA.
7. FOR ALL RETURN AIR, PROVIDE OPENINGS,
PATHWAYS, TRANSFERS, COORDINATE UNDERCUTS,
ETC. AS REQUIRED TO RETURN AIR SUPPLIED TO
SPACES BACK TO AIR HANDLING UNIT.
DUCT ACCESSORIES
1. COORDINATE WITH ARCHITECTURAL DRAWINGS AND
PROVIDE FIRE AND FIRE AND SMOKE DAMPERS AT
FIRE RATED ASSEMBLY PENETRATIONS IN
ACCORDANCE WITH THE INTERNATIONAL BUILDING
CODE AND WHERE SHOWN ON PLANS.
3. PROVIDE FLASHING MATERIALS AND OR SLEEVES AS
REQUIRED FOR ALL DUCT PENETRATIONS OF NON
RATED ELEMENTS. EXPOSED PENETRATIONS SHALL
BE FLASHED WITH SHEET METAL TIGHT TO WALLS.
4. PROVIDE HIGH EFFICIENCY TAKE OFFS, PEAL AND
STICK STYLE ATTACHED TO RECTANGULAR DUCTING
WITH SHEET METAL SCREWS FOR ALL ROUND
SUPPLY AIR TAKE OFFS AND SADDLES.
5. REGISTERS, GRILLES AND DIFFUSERS SHALL BE
EQUIVALENT TO SCHEDULED PRODUCTS.
SUBSTITUTION OF RESIDENTIAL STAMPED STYLE
PRODUCTS FOR COMMERCIAL PRODUCTS WILL NOT
BE ACCEPTED.
DUCT INSULATION
1. ALL DUCT INSULATION MATERIALS SHALL HAVE A
FLAME SPREAD RATING OF 25 OR LESS (ON THE
FLAME SPREAD TEST SCALE) AND SMOKE
DEVELOPMENT OF 50 OR LESS (ON THE SMOKE TEST
SCALE) OR AS DEFINED BY NFPA 255 STANDARD
METHOD OF TESTING OF SURFACE BURNING
CHARACTERISTICS OF BUILDING MATERIALS, LOCAL
CODES AND LOCAL AUTHORITIES HAVING
JURISDICTION. DUCT WRAP SHALL BE FIBERGLASS
MATERIAL PER ASTM C-411,ASTM C-1104,ASTM C665,
ASTM C-1338, ASTM E-84, UL723, NFPA 90A,CAN/ULC
S102-1188,ASTM C1290, ASTM C553, ASTM C1136.
2. INSULATION: INSTALL ALL INSULATION IN STRICT
ACCORDANCE WITH MANUFACTURERS
INSTRUCTIONS IN A TIGHT AND NEAT MANOR. NO
SAGGING, FRAYED OR TORN INSULATION WILL BE
EXCEPTED. UNLESS OTHERWISE NOTED ON PLANS
DUCTWORK SHALL BE INSULATED AS FOLLOWS:
SA- 1-1/2" FIBERGLASS DUCT WRAP WITH
FSK FACING, 75 #/FT3 MINIMUM APPLIED
R-3.5.
RA NONE REQUIRED UNLESS NOTED ON
PLANS.
SA/RA IN RETURN AIR PLENUMS OR
CONDITIONED SPACES WHERE NOT
CONCEALED BY DRYWALL CEILING OR
BULKHEAD CONSTRUCTION WITHIN THE
BUILDING INSULATION LINE NONE
REQUIRED.
LINERS: PLENUMS, REGISTER BOXES, AND RTU
DROPS SHALL BE MINIMUM 1" THICK
1-1/2 # DENSITY PER CU. FT., HAVING
MAT FACED OR MONOLITHIC
CONSTRUCTION WITH SKIN SMOOTH
MICROBIAL SURFACE TO WITHSTAND
VELOCITIES TO 4000 FPM. INSULATION
SHALL FIT SNUGLY AGAINST THE
INTERIOR DUCT SURFACES, AND BE
FASTENED TO THE DUCT WITH A 50%
HEAVY COAT OF RECOMMENDED
ADHESIVE AND METAL FASTENERS
WHICH DO NOT PIERCE THE DUCT,
SPACED AT 12” CENTERS. ALL EXPOSED
EDGES OF THE INSULATION SHALL BE
COATED WITH MANUFACTURED
RECOMMENDED ADHESIVE. SIZES ON
PLANS INDICATE FREE AREA.
EA- NONE REQUIRED UNLESS NOTED ON
PLANS.
OA- IN UNCONDITIONED OR ATTIC SPACES
OUTSIDE THE BUILDING ENVELOPE;
1-1/2" MINIMUM R-3.5 FSK DUCT WRAP.
OA- EXPOSED OR IN MECHANICAL ROOMS,
1-1/2 FIBERGLASS RIGID BOARD
INSULATION WITH FOIL SCRIM LAGGED
WITH 0.024 Al JACKET.
OA- IN UNCONDITIONED OR ATTIC SPACES
OUTSIDE THE BUILDING ENVELOPE;
1-1/2" FIBERGLASS DUCT WRAP WITH
FSK FACING, 75 #/FT3 MINIMUM APPLIED
R-4.0 INSTALLED IN STRICT
ACCORDANCE WITH MANUFACTURERS
INSTRUCTIONS
PIPING
3. REFRIGERATION PIPING;
A. SYSTEMS 5 TONS OR LESS; MANUFACTURED
REFRIGERANT LINE SETS: ANNEALED-COPPER
SUCTION AND LIQUID LINES FACTORYCLEANED,
DRIED, PRESSURIZED WITH NITROGEN, SEALED, AND
WITH SUCTION LINE INSULATED. PROVIDE IN
STANDARD LENGTHS FOR INSTALLATION WITHOUT
JOINTS, EXCEPT AT EQUIPMENT CONNECTIONS OR
ACCESSIBLE LOCATIONS. CONNECTIONS AND
WROUGHT-COPPER FITTINGS WHERE REQUIRED
SHALL BE BRAZED WITH MINIMUM 8% SIL-FLOS.
B. ALL INSULATION EXPOSED TO OUTDOORS SHALL BE
EITHER PVC LAGGED OR SHALL BE PAINTED WITH
ARMA-FINISH FR UV PROTECTING PAINT.
C. LINES SHALL BE RUN KINK FREE AND GENERALLY
CONTINUOUS AND AT 90 DEGREE ANGLES TO
STRUCTURE. AVOID JOINTS WHEN POSSIBLE. ALL
REQUIRED JOINTS SHALL BE MADE IN ACCESSIBLE
LOCATIONS OR M.C. SHALL PROVIDE ACCESS
PANELS AS NEEDED. ALL BENDS SHALL BE MADE
WITH LONG RADIUS FITTINGS OR WITH MECHANICAL
BENDING TOOL TO PROVIDE SMOOTH LONG RADIUS
TURNS. SUPPORT ALL PIPING WITHOUT CRUSHING
OR DEPRESSING INSULATION. USE REFRIGERATION
STYLE CUSH CLAMPS MOUNTED TO STRUT, DO NOT
LAY PIPING ON STRUCTURAL BUILDING MEMBERS.
SLEEVE ALL PENETRATIONS AND SEAL WATER
TIGHT.
D. PRESSURE TEST, TRIPLE EVACUATE AND PREPARE
ALL PIPING IN STRICT ACCORDANCE WITH
MANUFACTURERS RECOMMENDATIONS.
5. CONDENSTATE PIPING
A. PROVIDE TRAPS BUILT FROM INDIVIDUAL FITTINGS
ON ALL EVAPORATOR DRAIN PANS MINIMUM DEPTH
1.5 TIMES BLOWER BLOCKED TIGHT STATIC
PRESSURE. ALL TRAPS SHALL BE CONSTRUCTED
WITH PVC 90S (MANUFACTURED RUNNING TRAP
FITTINGS ARE NOT ACCEPTABLE). PROVIDE ALL
TRAPS WITH CLEAN OUTS AND REMOVABLE CAPS AS
NEEDED FOR MAINTAINING LINES.
B. HVAC CONTRACTOR SHALL COORDINATE
CONDENSATE DISPOSAL POINTS WITH P.C. HVAC
CONTRACTOR IS RESPONSIBLE FOR PIPING FROM
EVAPORATOR COILS TO DISPOSAL POINT. P.C. IS
RESPONSIBLE FOR STAND PIPES, FLOOR AND HUB
DRAINS AS NEEDED.
C. MATERIALS: POLYVINYL CHLORIDE DRAIN, WASTE
AND VENT PIPE (PVC) SCHEDULE 40 MINIMUM SIZE
3/4" .WRAPPED IN RETURN AIR PLENUMS WITH RA
RATED MATERIAL.
D. PROVIDE CONDENSATE PUMPS AS REQUIRED WITH
HIGH LEVEL SHUT DOWN SWITCHES INTERLOCKED
TO A/C UNITS.
E. PITCH ALL PIPING MINIMUM 1
4" PER FOOT. SUPPORT
PIPING AT MINIMUM 5'-0" INTERVALS. SECURE FINAL
CONNECTION AT SEWER WITH MINIMUM 1-1/2" AIR
GAP CONNECTION.
F. INSULATE ALL PIPING IN RA PLENUMS AND ABOVE
HARD CEILINGS WITH MINIMUM 3/8" WALL ARMAFLEX
INSULATION.
18. FIRE STOPPING.
a. FIRE STOPPING SYSTEMS SHALL BE IN FULL
COMPLIANCE WITH SECTIONS 714 AND 717 OF THE
IBC AND SECTION 607 OF THE IMC.
b. CONTRACTOR SHALL MAKE REFERENCE TO
ARCHITECTURAL PLANS AND PROVIDE ALL
REQUIRED FIRE STOPPING.
c. CONTRACTOR SHALL PROVIDE AHJ WITH FULL
SUBMITTAL INDICATING METHODS OF
CONSTRUCTION AND UL LISTINGS FOR EACH
PENETRATION SYSTEM USED.
d. DUCTS AND AIR TRANSFER OPENING
PENETRATIONS OF ASSEMBLIES REQUIRED TO BE
PROTECTED AND IN NON FIRE-RESISTANCE-RATED
FLOORS SHALL COMPLY WITH SECTIONS 717.
e. FIRE DAMPERS, SMOKE DAMPERS, COMBINATION
FIRE/SMOKE DAMPERS AND CEILING RADIATION
DAMPERS LOCATED WITHIN AIR DISTRIBUTION AND
SMOKE CONTROL SYSTEMS SHALL BE INSTALLED
IN ACCORDANCE WITH THE REQUIREMENTS OF
SECTION 607 OF THE IMC. AND THE
MANUFACTURER'S INSTALLATION INSTRUCTIONS
AND LISTING.
f. ACCESS DOORS SHALL BE PERMITTED IN CEILINGS
OF FIRE-RESISTANCE-RATED FLOOR/CEILING AND
ROOF/CEILING ASSEMBLIES PROVIDED SUCH
DOORS ARE TESTED IN ACCORDANCE WITH ASTM E
119 OR UL 263 AS HORIZONTAL ASSEMBLIES AND
LABELED BY AN APPROVED AGENCY FOR SUCH
PURPOSE. ALL ACCESS DOORS SHALL BE
PROVIDED BY TRADE MAKING PENETRATIONS.
CHECK TEST AND START UP REQUIREMENTS
1. ALL HVAC EQUIPMENT INSTALLATIONS SHALL BE
VERIFIED AND STARTED UP PER MANUFACTURERS
RECOMMENDATIONS. VERIFY ALL MODES OF
OPERATION. CONFIGURE ALL CONTROLS AND
PROGRAM OCCUPANCIES PER OWNER PROVIDED
SCHEDULES.
2. LABEL ALL MAJOR PIECES OF EQUIPMENT WITH
LAMACOID PLASTIC, BLACK WITH WHITE LETTERS.
SIZE TO BE CONSISTENT WITH EQUIPMENT BEING
LABELED. LENGTH AND WIDTH VARY FOR REQUIRED
LABEL CONTENT. THERMOSTAT AND SENSOR
LABELS SHALL BE ADJUSTED TO PROVIDE ESTHETIC
APPEARANCE.
3. PROVIDE AIR BALANCE BY CONTRACTOR.
CONTRACTOR SHALL BALANCE SUPPLY, RETURN,
OUTSIDE, RELIEF AND EXHAUST AIR SYSTEMS IN
ACCORDANCE WITH CURRENT SMACNA, NEEB OR
AABC STANDARDS TO DESIGN VALUES AND PROVIDE
WRITTEN REPORT TO ARCHITECT. MECHANICAL
CONTRACTOR SHALL BE RESPONSIBLE FOR
PROVIDING ALL DEVICES, DRIVES, SHEAVES, MOTOR
CHANGES AND REWORK AS REQUIRED TO MEET
DESIGN REQUIREMENTS.
4. TEMPERATURE CONTROL WORK SHALL BE THE
RESPONSIBILITY OF THE HVAC CONTRACTOR.
PROVIDE ALL COMPONENTS INCLUDING T/S, T/S
WIRE (PLENUM RATED IN RA PLENUMS), SWITCHES,
ACTUATORS ETC. AS REQUIRED FOR A COMPLETE
SYSTEM. PRIOR TO ROUGH-IN COORDINATE FINAL
LOCATION FOR ALL CONTROLS WITH OWNERS
REPRESENTATIVE.
5. CLOSE OUT: PROVIDE MANUFACTURERS OPERATION
AND MAINTENANCE MANUALS, AIR BALANCE REPORT
AND AS BUILT DRAWINGS. PROVIDE (1) TRAINING
SESSION TO OWNER SELECTED PERSONNEL AS
REQUESTED AND PROVIDE WARRANTY
INFORMATION FOR ALL MANUFACTURERS
WARRANTED EQUIPMENT.
ABBREVIATIONSSYMBOLS
AFF ABOVE FINISHED FLOOR
ACCU AIR COOLED CONDENSING UNIT
AHU AIR HANDLING UNIT
AWH ARCHITECTURAL WALL HEATER
BDD BACK DRAFT DAMPER
BOD BOTTOM OF DUCT
BOB BOTTOM OF BEAM
BTUH BRITISH THERMAL UNIT PER HOUR
CFM CUBIC FEET PER MINUTE
CWH COMMERCIAL WALL HEATER
DEG F DEGREES FARENHEIT
DB DRY BULB
Ø ROUND DUCT
EA EACH OR EXHAUST AIR
EG EXHAUST GRILLE
EADB ENTERING AIR DRY BULB
EAWB ENTERING AIR WET BULB
EC ELECTRICAL CONTRACTOR
ECH ELECTRIC CEILING HEATER
EF EXHAUST FAN
ESP EXTERNAL STATIC PRESSURE " W.C.
EUH ELECTRIC UNIT HEATER
EWH ELECTRIC WALL HEATER
F FURNACE
FC FAN COIL
FD FIRE DAMPER
FD/SD FIRE AND SMOKE DAMPER
FPM FEET PER MINUTE
FPVAV FAN POWERED VAV
FT FEET
FSK FOIL SCRIM VAPOR BARRIER
GC GENERAL CONTRACTOR
GPM GALLONS PER MINUTE
GUH GAS UNIT HEATER
HD HOOD
HP HEAT PUMP OR HORSE POWER
IN INCHES
IR INFRA RED
LAT LEAVING AIR TEMPERATURE
LS LINEAR SLOT DIFFUSER
MAN MANUAL
MBH 1000 BTUH
MC MECHANICAL CONTRACTOR
MCC MOTOR CONTROL CENTER
MFR MANUFACTURER
MUA MAKE UP AIR
OA OUTSIDE AIR
PC PLUMBING CONTRACTOR
DHU DEHUMIDIFICATION UNIT
PRV PRESSURE RELIEF VALVE
PSI POUNDS PER SQUARE INCH
PTAC PACKAGED TERMINAL AIR CONDITIONER
RA RETURN AIR
RJ ROOF JACK
RPM REVOLUTIONS PER MINUTE
RTU ROOF TOP UNIT
SA SUPPLY AIR
TCC TEMPERATURE CONTROL CONTRACTOR
TSP TOTAL STATIC PRESSURE
UON UNLESS OTHERWISE NOTED
VAV VARIABLE AIR VOLUME
WC WALL CAP
WIC WALK IN COOLER
WIF WALK IN FREEZER
AIR COOLED CONDENSING UNIT
MANUAL VOLUME DAMPER LOCKING WITH SHAFT
FIRE DAMPER
ROUND MOTORIZED DAMPER
M
COMBINATION FIRE/SMOKE DAMPER
THERMOSTAT
EXHAUST GRILLE
ROOF EXHAUST FAN
TURNING VANES DOUBLE THICKNESS
XXX
X-#
FD
FD
SD
ROOF TOP UNIT
W/D
W/D
HORIZONTAL FURNACE OR FC WITH
SECONDARY DRAIN PAN
HORIZONTAL AIR COOLED CONDENSING UNIT
WALL MOUNTED EXHAUST FAN
SUPPLY AIR DIFFUSER
RETURN AIR REGISTER OR GRILLE
ROUND DIFFUSER
LINEAR OR SLOT DIFFUSER
CEILING MOUNTED EXHAUST FAN
ACCU
FC
F
AC
DIRECT DUCT MOUNTED REGISTER
DIFFUSER TAG
EWHELECTRIC WALL HEATER
SQUARE TO ROUND TRANSITION
SHEET METAL DUCT WIDTH BY DEPTH
LINED SHEET METAL DUCT FREE AREA WIDTH
BY DEPTH.
ACCESS DOOR
SQUARE SHEET METAL 90 PROVIDE WITH
DOUBLE THICKNESS TURNING VANES.
RADIUS SHEET METAL 90, R=1.5*D
ROUND BRANCH DUCT SADDLE ON ROUND
DUCT.
45 DEG BRANCH DUCT TAKE OFF ON
RECTANGULAR.
STRAIGHT ROUND TAP BRANCH DUCT TAKE
OFF.
M
RECTANGULAR MOTORIZED DAMPER
BOOT MOUNTED REGISTER
MARK
CFM
T
HPOR AIR COOLED HEAT PUMP
EF
VERTICAL FURNACE OR FC
RADIANT FIRE DAMPER RFD
THERMOSTAT IN LOCK BOX
SENSORS, TEMPERATURE, HUMIDITY
CARBON MONOXIDE SENSOR
CARBON DIOXIDE SENSOR
NITROGEN OXIDE SENSOR NO
CO2
CO
S
T
DUCT SMOKE DETECTOR SD
H
MOTOR CONTROL CENTER MCC
ACCESS DOOR
HVAC
ABBREVIATIONS,
SYMBOLS, &
SPECIFICATIONS
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
07/14/21
100 SF10 x 10197 SF10 x 2036 SF5 x 7.524 SF5 x 549 SF10 x 549 SF10 x 524 SF5 x 573 SF10 x 7.573 SF 10 x 7.549 SF10 x 549 SF10 x 5OFFICE
101
TELECOM
103BREAKROOM
102 WC
105
JANITOR
104
6" W.C.
S-2
140
10"Ø8"Ø8"Ø10"
WC10"Ø6"Ø MEF-5
150
EF-4
75
S-2
160
S-1
50
S-1
100
S-2
140
S-2
140
S-2
1408"ØS-2
140
14/12R-1
R-1
10"Ø 10"Ø
14/12
8"Ø
F-1
2.5 TON
T 8"Ø8"Ø
8"Ø
10"Ø
EF-1
75
M002
HVAC DETAILS,
AND SCHEDULES
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
30° MAX
O
CONCENTRIC
TRANSITION MAX, 45
DEG. DIVERGING AND
60 DEG. CONVERGING
OFFSET. PROVIDE MINIMUM 2"
STRAIGHT SECTION AT EACH
END. MAX 30 DEG.
ECCENTRIC TRANSITION MAX,
30 DEG.
30° MAX
NOTE:
IN GENERAL, ELBOWS TO HAVE
FULL TURNING RADIUS (R=A).
WHERE "R" IS EQUAL TO OR
GREATER THAN "A" MINIMUM
RADIUS (R) = 4 INCHES.
R=A
A
DUCT CONSTRUCTION DETAILSB
45 DEG.
OCL CONNECTION
TAKE OFF. HAMMER
LOCKED OR FLANGED AND
FULLY SEALED
RECTANGULAR
DUCT
BRANCH
AIR FLOWV.D.
45 DEG. HIGH EFFICIENCY
TAKE OFF COMPLETELY
SEALED
ROUND SHEET METAL
DUCT TO DIFFUSER
118"
NOTE:
DOUBLE THICKNESS
TURNING VANES TO BE USED
WHERE NORMAL RADIUS
ELBOW IS IMPRACTICAL
& WHERE ELBOW IS WITHIN 5
FT OF A
BRANCH TAKE-OFF.AIR FLOWAGA GAS SHUT OFF, DIRT LEG
AND UNION. PROVIDE TREATED
WOOD BLOCKING AND
GALVANIZED CLAMP SUPPORT.
PLACE EXTRA ROOF
MEMBRANE BETWEEN BLOCK
AND ROOF MEMBRANE. TYP.3/4 PVC TRAPPED COND.
DRAIN. PROVIDE CLEAN OUT
AND CONCRETE SPLASH
BLOCK.
FILTERED FRESH AIR INTAKE
HOOD MAINTAIN MINIMUM OF
10'-0" FROM ALL EXHAUST
AND PLUMBING VENTS
3" MIN.
CUT ROOF ONLY AS NEEDED
FOR DUCT DROPS. PROVIDE
R-13 BATT INSULATION
PLACED ON REMAINING DECK
FOR SOUND ABSORPTION.
ELECTRICAL DISCONNECT
BY UNIT MANUFACTURER MAINTAIN MINIMUM OF 10'-0"
FROM EDGE OF ROOF
48" LONG SHEET METAL DROPS
LINED WITH 1" DUCT LINER SIZE TO
MATCH CURB OPENING.
FLEXIBLE DUCT CONNECTOR.
PROVIDE NEOPRENE CURB
TAPE AT DUCT CONNECTION
SEAL AIR TIGHT.
STEEL ANGLE FRAME BY STEEL
ERECTION CONTRACTOR COORDINATE
SIZES WITH STEEL SHOP DRAWINGS.
H NO SCALE
ROOF MOUNT RTU DETAIL
NO SCALE
E SCALE: 1/4" = 1'-0"
ENLARGED OFFICE HVAC PLAN N
GENERAL NOTES:
1. REFERENCE SHEET M001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
2. REFERENCE SHEET M002 FOR DETAILS AND
SCHEDULES.
OFFICE AREA FURNACE DETAILA
PROVIDE LINED SHEET METAL
RETURN AIR FURNACE BOX
UNDER ALL FURNACES. NO SIDE
FURNACE CONNECTIONS
ALLOWED.
MANUFACTURERS FILTER RACK
WITH 2" PLEATED MERV 8 FILTER.
PVC VENT AND COMBUSTION AIR
PIPING ROUTED TO CONCENTRIC
ROOF VENT. PITCH TOWARD
FURNACE MINIMUM 1/4" PER FOOT.
INSTALL PER MANUFACTURERS
INSTRUCTIONS.
PROVIDE OPEN SITE DRAIN
CONNECTION TO PROTECT
COMBUSTION BLOWER
TRAPPED PRIMARY AND
INDEPENDENT SECONDARY 3/4"
PVC DRAIN LINE. ROUTE
SECONDARY TO DRAIN PAN.
ROUTE PRIMARY DRAIN TO
INDIRECTION CONNECTION
AT HUB/DRAIN IN MECH
ROOM. MINIMUM SLOPE 1/4"
PER FOOT. SECURE LINE
AND TIE OFF AT DRAIN.
UPFLOW
FURNACE
16" MIN.
MATCHING WIDTH CASED EVAPORATOR
COIL SEALED TO FURNACE AND SUPPLY
AIR DUCT.
REFRIGERATION GRADE TYPE L
COPPER LINE SET WITH 1/2" WALL
ARMAFLEX SIZE PER
MANUFACTURE
AGA GAS VALVE, DIRT LEG AND
UNION CONNECTED TO FURNACE.
PROVIDE MINIMUM 1-1/2 DEEP
SEALED SECONDARY DRAIN PAN
WITH MOISTURE SWITCH. WIRE
SWITCH TO SHUT DOWN FURNACE IF
PRIMARY DRAIN FAILS
RA DUCT TO ATTIC SEAL AIR
TIGHT AT CEILING PENETRATION
SA/RA DUCTS
FLEXIBLE DUCT CONNECTOR
M
FRESH AIR DUCT WITH MOTORIZED
DAMPER INTERLOCKED TO
FURNACE BLOWER. PROVIDE
MANUAL VD AND BALANCE TO
SCHEDULED CFM.
NO SCALE
LAY-IN DIFFUSER DETAIL
NO SCALE D
SECURE FLEXIBLE DUCT TO
SUPPLY DIFFUSER ELBOW
FITTING WITH DRAWBANDS.
SHEET METAL ELBOW
SEAL ALL RIBS AND
CONNECTION TO
DIFFUSER NECK
SUPPLY DIFFUSER ACT CEILING
FLEX DUCT MAXIMUM LENGTH
SHALL NOT EXCEED 7'-0"
REFERENCE ARCHITECTURAL
REFLECTED CEILING PLAN AND
ELECTRICAL LIGHTING PLAN AND
COORDINATE INSTALLATION WITH ALL
CEILING ELEMENTS.
RA
DROP
E RTU-1 RA DROP DETAIL
SCALE: NONE
GALVANIZED DUCT HANGER
STRAP SECURED TO
STRUCTURE ABOVE.
FRAMED OPENING ON TOP
OF DUCT COVERED WITH
GALVANIZED WELDED WIRE
SCREEN. 20X20.
SECURE AND SEAL
DROP TO RTU CURB
FRAME.
BUTTER TOP OF
LINER FULL
PERIMETER OF
OPENING
MINIMUM 48" LINED DUCT
RUN OUT MOUNTED AS
HIGH AS POSSIBLE.
WITH ROOFING CONTRACTOR
COORDINATE LOCATION/TYPE
PITCH
POCKET
MOUNTED ON 2" SQUARE
AIR COOLED CONDENSER
SLOPE GALVANIZED EQUIPMENT RAIL
EQUIPMENT SUPPORTS LIKE PATE EQ-1
NEMA 3R DISCONNECT
SIZED AND INSTALLED PER
NEC. MOUNT TO SIDE OF UNIT
GFCI WHERE SHOWN ON
PLANS
MIN. 8"
VIBRATION PAD LIKE DIVERSITECH
#MP-2E ANTI-VIBRATION PAD
MECHANICALLY FASTENED
LINE SETS VIA CUSH CLAMPS
AND TREATED 4x4'S
REFRIGERANT TUBING WITH 1/2" WALL
MIN. ARMAFLEX INSULATION. INSULATION
LOCATED OUTDOORS SHALL BE PAINTED
WITH UV RESISTANT ARMAFLEX PAINT.
INVERTED TRAP, PITCH SUCTION LINE
TOWARD COMPRESSOR. PROVIDE OIL
RETURN TRAPS PER MANUFACTURES
PIPING RECOMMENDATIONS.
INSTALL ALL REFRIGERATION
SPECIALTIES AS INDICATED ON
EQUIPMENT SCHEDULES.
C SCALE: NONE
ROOF MOUNT ACCU DETAIL
WITH SLIP SHEET UNDER RAIL SET ON ROOF MEMBRANE
1 10/15/20BID ADDEN. 002
1
1
1
1
1
07/14/21
UP
A
1
A.1 B B.1 C C.1 D
2
3
4
5
6
7
8
9
10
11
12
13
1414
15
16
17
OFFICE
101
ELEC.
106
STAIR
108
SPRINKLER
107
ELEV.
109
TELECOM
103
STORAGE
UNITS
100
CONC
P2 1
CORRIDOR
110
BREAKROOM
102 WC
105JANITOR
104
100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10197 SF10 x 2024 SF5 x 549 SF10 x 5147 SF10 x 15147 SF10 x 15145 SF10 x 1573 SF10 x 7.573 SF10 x 7.573 SF10 x 7.572 SF10 x 7.536 SF5 x 7.524 SF5 x 549 SF10 x 549 SF10 x 599 SF10 x 1099 SF10 x 1049 SF10 x 524 SF5 x 549 SF10 x 549 SF 10 x 5 49 SF 10 x 5 49 SF 10 x 5 49 SF 10 x 5 49 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 5153 SF10 x 15 153 SF10 x 15151 SF10 x 1549 SF10 x 549 SF10 x 599 SF10 x 1024 SF5 x 5147 SF10 x 1573 SF10 x 7.573 SF10 x 7.573 SF10 x 7.549 SF10 x 549 SF10 x 5EWH-1
EWH-1
EF-3
600
S-4
200
S-4
200
S-3
200
S-4
200
S-4
200
S-3
200
S-3
200
S-3
200
S-3
200
S-4
200
S-4
200
16/10 14/10 10"Ø10"Ø20/12 8"Ø S-3
200
20/12 UP T
8"Ø12/10 LV-1
17
A A.1 B B.1 C C.1 D
32
18
19
20
21
22
23
24
25
26
27
28
29
30
31
STAIR
111
STORAGE
UNITS
100
CONC
P2 1
VESTIBULE
112100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1049 SF 10 x 5 49 SF 10 x 5 49 SF 10 x 5 49 SF 10 x 5 49 SF 10 x 5 49 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 549 SF10 x 599 SF10 x 10252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25153 SF10 x 15252 SF10 x 25249 SF10 x 25253 SF10 x 25157 SF10 x 1598 SF10 x 1049 SF 10 x 5 49 SF10 x 599 SF10 x 1049 SF10 x 524 SF5 x 549 SF10 x 5252 SF10 x 25252 SF10 x 25252 SF10 x 2524 SF5 x 549 SF10 x 549 SF10 x 5100 SF10 x 10EWH-1
S-3
200
S-3
200
S-3
200
S-3
200
S-3
200
S-3
200
S-3
200
S-4
200
S-4
200 10/1012/10 10/10 10"Ø22/10
24/14 UP 10/10 10"Ø8"Ø8"Ø10"ØS-3
20010"Ø 10/10 14/10 EWH-1
M100
FIRST FLOOR
HVAC PLAN
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
1 SCALE: 1/8" = 1'-0"
FIRST FLOOR HVAC PLAN AREA A 2 SCALE: 1/8" = 1'-0"
FIRST FLOOR HVAC PLAN AREA B
NOT USED
NOT USED
PROVIDE COOLING ONLY, LINE VOLTAGE
THERMOSTAT.
KEY NOTES:
GENERAL NOTES:
1. REFERENCE SHEET M001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
2. REFERENCE SHEET M002 FOR DETAILS AND
SCHEDULES.
N
1
M002
MATCH LINE A-A
MATCH LINE A-A
MATCH LINE A-A MATCH LINE A-A
1
2
1
1
1
1 10/15/20BID ADDEN. 002
1
3
3
07/14/21
DN
UP
A
1
A.1 B B.1 C C.1 D
2
3
4
5
6
7
8
9
10
11
12
13
14
15
ELEV.
202
STAIR
201
201STORAGE
UNITS
200
CONC
P2 1
ENCLOSED SOFFIT
SPACE102 SF10 x 10102 SF10 x 1099 SF10 x 10150 SF10 x 15100 SF10 x 10100 SF10 x 10100 SF10 x 10154 SF10 x 15102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10187 SF10 x 18.599 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF 10 x 1099 SF10 x 1099 SF10 x 1049 SF10 x 5134 SF10 x 13.5147 SF10 x 15145 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15148 SF10 x 15148 SF10 x 1549 SF10 x 549 SF10 x 549 SF10 x 5199 SF10 x 2049 SF10 x 549 SF10 x 525 SF5 x 599 SF10 x 1099 SF10 x 1099 SF10 x 10102 SF10 x 10102 SF10 x 10149 SF10 x 15149 SF10 x 15134 SF10 x 13.5149 SF10 x 1549 SF10 x 599 SF10 x 1016/10 12"Ø 10"ØS-4
200
S-4
200
S-4
200
S-3
200
S-3
200
S-3
200
S-3
200
S-3
200
S-4
200
S-4
200
S-4
200
S-3
200
20/12 14/10 12"Ø 14/10 12"Ø S-4
200
S-4
20010"Ø10"Ø 10"ØS-4
200
24/16
18/12 10"Ø
20/12 DN
26/22 UP26/24 UP FD FD 20/12 DN
24/14
T
15
A A.1 B B.1 C C.1 D
32
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
STAIR
203203 STORAGE
UNITS
200
CONC
P2 1
ENCLOSED SOFFIT
SPACE
104 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10199 SF10 x 20199 SF10 x 2099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10199 SF10 x 20199 SF10 x 20199 SF10 x 20199 SF10 x 20199 SF10 x 20199 SF10 x 20199 SF10 x 20199 SF10 x 2099 SF10 x 1099 SF10 x 10199 SF10 x 20199 SF10 x 20156 SF10 x 1549 SF10 x 524 SF5 x 549 SF10 x 524 SF5 x 5149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15102 SF10 x 10102 SF10 x 10102 SF10 x 10149 SF10 x 15102 SF10 x 10S-4
200
S-4
200
S-4
200
S-3
200
S-3
200
S-4
200
S-4
200
S-4
200
S-3
200
S-3
200
S-4
20012/10 10"Ø 14/1012/12
18/10 10"Ø
8"Ø
8"Ø10"ØS-4
200
22/12
24/14 DN
24/14 DN
26/22 UP26/24 UP FD FD
22/12
T
S-4
20010"Ø 14/10M200
SECOND FLOOR
HVAC PLANS
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
1 SCALE: 1/8" = 1'-0"
SECOND FLOOR HVAC PLAN AREA A 2 SCALE: 1/8" = 1'-0"
SECOND FLOOR HVAC PLAN AREA B
MATCH LINE A-A
MATCH LINE A-A MATCH LINE A-A
N
NOT USED
NOT USED
NOT USED
NOT USED
PROVIDE FIRE DAMPER AT FLOOR PENETRATION.
NOT USED
KEY NOTES:
GENERAL NOTES:
1
1. REFERENCE SHEET M001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
2. REFERENCE SHEET M002 FOR DETAILS AND
SCHEDULES.
2
3
4
5
5
5
6
1
1
1
1 10/15/20BID ADDEN. 002
1
07/14/21
DN
A
1
A.1 B B.1 C C.1 D
2
3
4
5
6
7
8
9
10
11
12
13
14
15
ELEV.
302
STAIR
301
STORAGE
UNITS
300
15102 SF10 x 10102 SF 10 x 1099 SF10 x 10150 SF7.5 x 12.599 SF10 x 1099 SF10 x 1099 SF10 x 10153 SF7.5 x 12.549 SF10 x 599 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10103 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF 10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10148 SF10 x 13.5139 SF10 x 13.5134 SF10 x 13.5141 SF10 x 13.5147 SF10 x 15145 SF10 x 15149 SF10 x 15149 SF10 x 1549 SF10 x 549 SF 10 x 549 SF10 x 598 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1049 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 5149 SF10 x 15149 SF10 x 1599 SF10 x 1020 SF5 x 320 SF5 x 3102 SF10 x 10102 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10102 SF10 x 1099 SF10 x 1049 SF10 x 549 SF10 x 549 SF10 x 5S-4
200
S-4
200
S-4
200
S-3
200
S-3
200
S-3
200
S-4
200
S-4
200
S-3
200
S-3
200
S-4
200
S-4
200
S-3
200
S-4
200
S-4
200
18/12 8"Ø16/10 14/10 10"Ø20/10 16/1012/10 10"Ø 12"Ø 10"Ø30/12
10"Ø
26/22 DN36/24 UP
40/22 UPFD FD26/24 DN
30/12
15
A A.1 B B.1 C C.1 D
32
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
STAIR
303
STORAGE
UNITS
300 99 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 1599 SF10 x 1099 SF10 x 1099 SF10 x 10149 SF10 x 15150 SF10 x 1591 SF10 x 10149 SF10 x 15154 SF10 x 15149 SF10 x 15149 SF10 x 1549 SF10 x 549 SF10 x 549 SF10 x 5149 SF10 x 15149 SF10 x 1599 SF10 x 10S-4
200
S-3
200
S-3
200
S-3
200
S-3
200
S-3
200
S-4
200
S-4
200
S-4
200
S-4
200
S-3
200
S-3
200
S-3
200
S-4
200
S-4
2008"Ø8"Ø
12/1016/1014/10 10"Ø 12"Ø 10"Ø 16/10 20/10 30/12
18/12
36/24 UP 40/22 UPFD FD
10"Ø26/24 DN 26/22 UP
30/12
M300
THIRD FLOOR HVAC
PLAN AREA
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
1 SCALE: 1/8" = 1'-0"
THIRD FLOOR HVAC PLAN AREA A 2 SCALE: 1/8" = 1'-0"
THIRD FLOOR HVAC PLAN AREA B
MATCH LINE A-A MATCH LINE A-A
N
MATCH LINE A-A MATCH LINE A-A
PROVIDE FIRE DAMPER AT FLOOR PENETRATION.
KEY NOTES:
GENERAL NOTES:
1
1. REFERENCE SHEET M001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
2. REFERENCE SHEET M002 FOR DETAILS AND
SCHEDULES.
1
1
07/14/21
A
1
A.1 B B.1 C C.1 D
2
3
4
5
6
7
8
9
10
11
12
13
14
1515
RTU-1
20 TON
ACCU-1
2.5 TON
15
A A.1 B B.1 C C.1 D
32
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
RTU-2
20 TON
M400
ROOF HVAC PLAN
AREA
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
1 SCALE: 1/8" = 1'-0"
THIRD FLOOR HVAC PLAN AREA A 2 SCALE: 1/8" = 1'-0"
THIRD FLOOR HVAC PLAN AREA B
MATCH LINE A-A MATCH LINE A-A
N
MATCH LINE A-A MATCH LINE A-A
GENERAL NOTES:
1. REFERENCE SHEET M001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
2. REFERENCE SHEET M002 FOR DETAILS AND
SCHEDULES.
07/14/21
P001
ABBREVIATIONS
HW
SAN
PIPING LINETYPES
HEATING WATER SUPPLY DOMESTIC
SANITARY SEWER
COLD WATER DOMESTIC
SYMBOLS
CW
GASGAS NATURAL OR PROPANE
ANCHOR / HANGER
BALL VALVE
GAS METER
PIPE GUIDE
"P" TRAP
TEST PLUG
PLUG VALVE
WATER METER
UNION
THERMOMETER
"Y" STRAINER
PRESSURE GAUGE
DROP
PITCH DOWN IN DIRECTION OF ARROW
RUN OUT OFF BOTTOM OF MAIN
RUN OUT OFF TOP OF MAIN
RISER
TEE OFF SIDE OF MAIN
PIPING SYMBOLS
M
GM
P
PLUMBING SPECIFICATIONS
GENERAL
1. BID INSTRUCTIONS: CONTRACTORS SHALL PROVIDE BASE BID IN
STRICT ACCORDANCE WITH DESIGN BASIS EQUIPMENT AND
MATERIALS. PROJECT DOES ENCOURAGE COMPETITIVE PRICING
AND ALLOWS FOR SUBSTITUTIONS OF EQUAL EQUIPMENT AND
MATERIALS AGAINST THE BASIS OF DESIGN. SUBSTITUTE ITEMS
WILL BE COMPARED AGAINST DESIGN BASIS DURING SUBMITTAL
PROCESS. ENGINEER RESERVES THE RIGHT TO REJECT
SUBSTITUTIONS FOUND NOT TO BE EQUAL TO ITEMS LISTED IN
DESIGN BASIS.
2. PRIOR TO PROCUREMENT CONTRACTOR SHALL SUBMIT TO
ARCHITECT FULL SUBMITTALS FOR ALL ENERGY CONSUMING OR
PRODUCING ITEMS AND FOR ALL PLUMBING FIXTURES, VALVES,
DRAINS, CLEAN OUTS, PIPING, PIPING ACCESSORIES, INSULATION
AND PIPING HANGERS. SUBMITTALS SHALL BE DELINEATED WITH
TAGS INDICATED ON PRINTS, CONTRACTORS NAME, PROJECT NAME.
CLEARLY INDICATE ALL MODEL NUMBERS AND ALL ACCESSORIES
AND OPTIONS BEING PROVIDED. SUBMISSIONS SHALL BE IN PDF
FORMAT.ENGINEER RESERVES THE RIGHT TO REJECT ANY
SUBSTITUTE ITEM.
3. CONTRACTOR SHALL BE RESPONSIBLE TO VISIT THE SITE TO
EXAMINE ALL CONDITIONS THAT MAY IN ANY WAY AFFECT THE
EXECUTION OF HIS WORK. HE SHALL ALSO EXAMINE THE DRAWINGS
AND SPECIFICATIONS FOR OTHER BRANCHES OF WORK MAKING
REFERENCE TO THEM FOR DETAILS OF EXISTING BUILDING
CONDITIONS. NO EXTRAS WILL BE ALLOWED FOR FAILURE TO
INCLUDE ALL REQUIRED WORK IN THE BID. CONTRACTOR SHALL
GUARANTEE ALL LABOR AND MATERIALS ENTERING INTO CONTRACT
FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE.
4. THE DRAWINGS IN THIS SECTION ARE DIAGRAMMATIC AND ARE NOT
INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED
REQUIREMENTS. DRAWINGS SHOW GENERAL INTENT OF SYSTEMS.
P.C. SHALL PROVIDE AND PAY FOR ALL REQUIRED PERMITS.
5. UPON COMPLETION OF THE PLUMBING INSTALLATION,
DEMONSTRATE TO THE ENGINEER AND/OR THE OWNER'S
SATISFACTION THAT THE SYSTEMS HAVE BEEN INSTALLED IN
ACCORDANCE WITH THE DRAWINGS, SPECIFICATIONS AND
APPLICABLE CODES. DEMONSTRATE THE DYNAMIC OPERATION OF
EACH SYSTEM. VERIFY PROPER OPERATION OF EQUIPMENT,
FILTERS ARE CLEAN AND COMPONENTS OF THE SYSTEM ARE
INSTALLED AND ADJUSTED IN FULL ACCORDANCE WITH
MANUFACTURER RECOMMENDATIONS.
6. PLUMBING WORK SHALL BE COMPLETE IN EVERY DETAIL AND ALL
MISCELLANEOUS ITEMS OF MATERIAL AND LABOR NECESSARY TO
COMPLETE THE WORK DESCRIBED, SHOWN OR REASONABLY
IMPLIED ON DRAWINGS OR SPECIFICATIONS SHALL BE INCLUDED IN
THE CONTRACT. CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS
TO THE WORK WHERE REQUIRED, WHEN SUCH ADJUSTMENTS ARE
NECESSARY FOR PROPER OPERATION AND WITHIN THE INTENT OF
THE CONTRACT. CONTRACTOR SHALL GUARANTEE ALL LABOR AND
MATERIALS ENTERING INTO CONTRACT FOR A PERIOD OF ONE (1)
YEAR FROM DATE OF ACCEPTANCE.
7. ALL WORK SHALL BE IN FULL ACCORDANCE WITH 2012 INDIANA
PLUMBING CODE (INTERNATIONAL PLUMBING CODE 2006), 2010
INDIANA ENERGY CODE (2007 ASHRAE 90.1), 2014 INDIANA FUEL GAS
CODE (2012 INTERNATIONAL FUEL GAS CODE) AND ALL PERTINENT
STATE, COUNTY, CITY CODES AND ORDINANCES WITH INDIANA
AMENDMENTS.
8. PLUMBING CONTRACTOR SHALL ACCEPT SOLE AND COMPLETE
RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING
SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE
OF THE WORK.
9. DURING CONSTRUCTION ALL PLUMBING FIXTURES, TRIM AND OTHER
EQUIPMENT SHALL BE PROTECTED AGAINST DAMAGE OR INJURY.
ANY FIXTURES OR EQUIPMENT DAMAGED AND ANY TRIM WITH
MARRED OR SCRATCHED FINISH SHALL BE REPLACED AT NO
ADDITIONAL COST TO THE OWNER.
10. PLUMBING CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR
ALL WATER, GAS, STORM AND SEWER UTILITY ROUGH-INS AND
SHALL CONSULT WITH THE CIVIL PLANS AND WITH LOCAL UTILITY
COMPANY(S) PROVIDING ALL MATERIALS AND LABOR AND PAYING
ALL COSTS NOT BORNE BY THE LOCAL UTILITY COMPANY(S) FOR
INSTALLATION OF SERVICES INCLUDING SECURING AND PAYING FOR
ALL REQUIRED PERMITS.
11. PLUMBING CONTRACTOR SHALL ENSURE EMPLOYEES ARE MEETING
AND DOCUMENTING ALL OSHA AND JOB SPECIFIC SAFETY
REQUIREMENTS AS REQUIRED BY LAW AND BY CONTRACT.
PERSONAL PROTECTIVE EQUIPMENT SHALL BE PROVIDED AND
UTILIZED AS REQUIRED. MECHANICAL CONTRACTOR SHALL PAY ALL
FINES LEVIED BY OSHA FOR FAILURE TO COMPLY WITH OSHA
REQUIREMENTS.
12. ALL PLUMBING MATERIALS INSTALLED IN RETURN AIR PLENUMS
SHALL BE INSTALLED OR COVERED WITH MATERIALS AS REQUIRED
TO PROVIDE FLAME RATING OF NOT MORE THAN 25 AND A SMOKE
DEVELOPED INDEX OF NOT MORE THAN 50. PRIOR TO ROUGH-IN
CONSULT WITH M.C. TO VERIFY ALL LOCATIONS OF RETURN AIR
PLENUMS.
13. FURNISH AND INSTALL ACCESS PANELS FOR ALL CONCEALED
EQUIPMENT, PIPING VALVES, CLEANOUTS, ETC. ACCESS PANELS
SHALL BE OF SUFFICIENT SIZE TO PROVIDE ADEQUATE WORKING
CLEARANCE AND ACCESS.
14. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
REQUIRED CUTTING AND PATCHING INCLUDING SAW CUTTING AND
PATCHING OF EXISTING FLOORS AS REQUIRED TO ACCEPT NEW
FLOORING.
15. UNLESS OTHERWISE NOTED, ROUTE ALL PIPING AS HIGH AS
POSSIBLE AND ROUTE PERPENDICULAR AND/OR PARALLEL TO
BUILDING STRUCTURE.
EQUIPMENT
1. PROVIDE EQUIPMENT AS SHOWN ON EQUIPMENT SCHEDULES AND
PLAN NOTES. SUBSTITUTIONS TO LISTED EQUIPMENT SHALL BE AT
RISK OF CONTRACTOR. SUBSTITUTIONS SHALL ONLY BE ALLOWED IF
ITEMS ARE EQUAL IN ALL ASPECTS.
2. PROVIDE SUBMITTALS TO ELECTRICIAN AS REQUIRED FOR
COORDINATION OF ALL REQUIRED ELECTRICAL POWER WIRING.
INCLUDE WIRING DIAGRAMS AND CABLING REQUIREMENTS FOR
REFERENCE. COORDINATE ALL INTERLOCKS AS NEEDED. PROVIDE
SINGLE POINT CONNECTION KITS AS NEEDED.
3. INSTALL ALL EQUIPMENT IN FULL ACCORDANCE WITH
MANUFACTURERS RECOMMENDATIONS AND CLEARANCE
REQUIREMENTS. PROVIDE ALL REQUIRED MOUNTING OR
HOUSEKEEPING PADS. G.C. SHALL PROVIDE LEVEL GRADE FOR
EXTERIOR MOUNTED EQUIPMENT. P.C. SHALL PROVIDE ALL
HOISTING AND RIGGING NEEDED TO SET ALL PLUMBING EQUIPMENT.
4. ALL EQUIPMENT SHALL BE INSTALLED AS NEEDED TO PREVENT
OBJECTIONABLE NOISE AND/OR VIBRATION. P.C. SHALL PROVIDE
VIBRATION PADS, SPRING ISOLATORS, ATTENUATORS AND
ACCESSORIES AS NEEDED.
5. PROVIDE ALL BLOCKING, HANGERS, SHELVES, BRACKETS ETC. AS
REQUIRED TO INSTALL ALL PLUMBING EQUIPMENT.
6. INSTALL WATER HEATERS IN ACCORDANCE WITH NFPA-70, AND THE
NATIONAL ELECTRICAL CODE. PROVIDE BRASS DRAIN VALVE, 3/4"
RELIEF VALVE AND COLD WATER DIP TUBE. INSTALL HEATERS PER
MANUFACTURES INSTALLATION INSTRUCTIONS. PROVIDE SHUT-OFF
VALVES FOR SERVICE WORK.
7. THERMOSTATS ON WATER HEATER SHALL NOT BE USED FOR
LIMITING HOT WATER TEMPERATURES.
P.C. SHALL PROVIDE MIXING VALVES FOR HOT WATER TO ALL
HANDS-FREE FAUCETS ACCESSIBLE TO OCCUPANTS. MIXING VALVE
SYSTEMS SHALL LIMIT WATER TEMPERATURE AT FAUCETS TO 110
DEG F. OR LESS.
8. PROVIDE SCHEDULE 40 PVC PIPING AND FITTINGS FOR ALL
COMBUSTION AIR AND VENT PIPING IN ACCORDANCE WITH
MANUFACTURERS INSTRUCTIONS ON ALL DIRECT VENT WATER
HEATERS OR BOILERS.
FIXTURES
1. REFERENCE FIXTURE SCHEDULES ON PLANS AND PROVIDE ALL
REQUIRED CARRIERS, BLOCKING, HANGERS, TAIL PIECES, TRAPS,
RISERS, ESCUTCHEONS, GRIDS, PUTTY, GASKETS, CAULKING, ETC.
AS REQUIRED TO INSTALL ALL PLUMBING FIXTURES.
2. REVIEW SUBMITTALS FOR ALL OWNER PROVIDED EQUIPMENT AND
PROVIDE ANY REQUIRED ACCESSORIES AS NEEDED FOR A
COMPLETE INSTALLATION. P.C. SHALL BE RESPONSIBLE TO RECEIVE
AND INSTALL ALL OWNER PROVIDED FIXTURES.
3. FIXTURES DESIGNATED FOR HANDICAP ACCESSIBILITY SHALL
COMPLY WITH ANSI A 117.1, LATEST EDITION, INCLUDING ADOPTED
INDIANA AMENDMENTS.
4. PROVIDE ALL CODE REQUIRED BACKFLOW DEVICES FOR PROCESS
HVAC EQUIPMENT AND FOR WATER SERVING ANY DRINKING OR
FOOD PREPARATION FIXTURES.
5. PROVIDE BELLOWS TYPE WATER HAMMER ARRESTERS, STAINLESS
STEEL CASHING AND BELLOWS, 250 PSI, INSTALL PER PDI STANDARD
WH201.
PIPING
1. ALL EXPOSED SUPPLY PIPES AND METAL TRIM IN CONNECTION WITH
THE FIXTURES SHALL BE CHROME PLATED RED BRASS OR BRONZE,
PROVIDE CHROME PLATED STOP VALVES IN ALL SUPPLIES TO ALL
FIXTURES. PLASTIC STOPS OR TRIM SHALL NOT BE ACCEPTABLE.
CAULK ALL FIXTURES WITH WATERPROOF SILICONE CAULK. TRAPS
SHALL HAVE CLEANOUT PLUGS. INSTALL ONE PIECE CHROME
ESCUTCHEON PLATE WITH SET SCREW AT WALL PENETRATIONS.
2. THE MINIMUM SLOPE OF A HORIZONTAL DRAINAGE PIPE SHALL BE:
a. 1/4" PER FOOT FOR PIPES UP TO 2-1/2".
b. 1/8" PER FOOT FOR PIPES 3" TO 6".
c. 1/16" PER FOOT FOR PIPES 8" OR LARGER.
MAINS AND LATERAL BRANCHES SHALL BE SLOPED TOWARD THE
BUILDING DRAIN. ALL PIPING SHALL BE INSTALLED AND TESTED IN
ACCORDANCE WITH THE CURRENT PLUMBING CODE AND PER THE
AUTHORITY HAVING JURISDICTION.
3. CLEAN OUTS SHALL BE INSTALLED WITH IN 5' OF THE FOUNDATIONS
AND AT THE BASE OF EACH STORM AND WASTE STACK, AND AT NOT
MORE THAN 75 FOOT INTERVALS ON ALL HORIZONTAL RUNS, AT THE
HIGH POINT OF THE BUILDING DRAIN AND PER THE CURRENT
PLUMBING CODE.
4. VERIFY LOCATION, DEPTH AND SIZE OF SANITARY SEWER
CONNECTION POINTS. CONNECT AS REQUIRED. OUTSIDE SEWER
SHALL BE INSTALLED WITH MINIMUM OF 3'-0" COVER. COORDINATE
CONNECTIONS WITH SITE CONTRACTOR AND LOCAL UTILITY
5. ALL OUTSIDE WATER PIPING SHALL BE COVERED PER LOCAL
REQUIREMENTS OR WITH A MINIMUM BELOW PREDICTED FROST LINE
WHICH EVER IS GREATER.
6. ALL INTERIOR PIPING PENETRATIONS THROUGH WALLS, CEILINGS,
ROOFS AND FLOORS SHALL BE SLEEVED AND SEALED. PROVIDE UL
LISTED FIRE STOPPING WHERE REQUIRED.
7. ALL EXTERIOR UNDERGROUND PENETRATIONS OF BUILDING
FOUNDATIONS OR SLAB FLOORS SHALL BE SLEEVED AND SEALED.
PENETRATIONS BELOW GRADE INTO THE BUILDING SHALL BE DONE
WITH MECHANICAL SEALS LIKE "LINK SEAL" OR EQUAL.
8. ALL PIPING PASSING THROUGH CONCRETE OR CINDER WALLS OR
SUBJECT TO EXPOSURE TO CONCRETE SHALL BE TAPED, SLEEVED
OR INSULATED TO PREVENT DIRECT CONTACT WITH CONCRETE.
9. NO PLUMBING PIPING SHALL PASS DIRECTLY OVER ELECTRICAL
PANELS OR DISTRIBUTION CABINETS. PRIOR TO ROUGH IN
COORDINATE WITH E.C.
10. DIELECTRIC UNIONS SHALL BE USED TO CONNECT DISSIMILAR
METALS OR METAL PIPING SHALL HAVE METAL CONNECTIONS ON
EACH END THREADED TO MATCH THE ADJACENT PIPING. METAL
COMPONENTS SHALL BE SEPARATED BY A NYLON INSULATOR TO
PREVENT CURRENT FLOW BETWEEN DISSIMILAR METALS. UNIONS
SHALL BE SUITABLE FOR THE SYSTEM OPERATING PRESSURES AND
TEMPERATURE WELD TYPE: ASTM A-234.
11. PIPING SLEEVES; INTERIOR OR EXTERIOR ABOVE GRADE;
GALVANIZED-STEEL-PIPE SLEEVES OR PVC-PIPE SLEEVES. VERIFY,
WITH FIRE AUTHORITIES HAVING JURISDICTION, THAT PVC
MATERIALS ARE ALLOWED FOR SLEEVES. BELOW GRADE; ALL;
MECHANICAL GALVANIZED-STEEL PIPE SLEEVE SYSTEM LIKE
LINK-SEAL. ALL SLEEVES SHALL BE FIRE STOPPED OR CAULKED.
EXTERIOR SLEEVES SHALL PROVIDE WATER/AIR TIGHT
PENETRATION SYSTEM.
12. PROVIDE HANGERS PER MSS AND IPC STANDARDS BASED ON PIPING
TYPES AND SIZES. WHERE EXPOSED TO VIEW IN PUBLIC SPACES,
RODS SHALL BE GALVANIZED.
13. VALVES: 2" AND SMALLER SHALL BE LIKE CRANE (3) PIECE 3800
SERIES BALL OR 438 SERIES GATE VALVES. 2-1/2" OR LARGER SHALL
BE LIKE CRANE SERIES G-3500 BALL OR 465 GATE VALVES.
14. UNIONS: PROVIDE AND INSTALL UNIONS AS REQUIRED FOR THE
INSTALLATION AND REMOVAL OF ALL EQUIPMENT.
15. STOPS: ALL FIXTURES SHALL BE INSTALLED WITH METAL 1
4 TURN
CHROME PLATED PLUMBING STOPS COMPATIBLE WITH PIPING
MATERIAL SERVING FIXTURES.
16. PIPING MATERIALS UNLESS OTHERWISE NOTED ON THE PLANS
SHALL BE AS FOLLOWS:
GAS ABOVE GRADE, 2" AND SMALLER; BLACK STEEL SCHEDULE
40 TYPE E OR S PIPE GRADE B; ASTM A53 / A53M, A105 OR
A120 WITH THREADED ENDS; FITTINGS SHALL BE
MALLEABLE IRON THREADED FITTINGS ASTM B16.3 CLASS
150.
P.C. OPTION: IF AVAILABLE COORDINATE 2 PSIG SERVICE
WITH PUBLIC UTILITY AND RESIZE PIPING BASED ON 2 PSIG
WITH 1 PSIG MAXIMUM PRESSURE LOSS AND PROVIDE
AND INSTALL VENTLESS GAS REGULATORS LIKE MAXITROL
325 SERIES TO REGULATE 2 PSIG DISTRIBUTION
PRESSURE TO APPLIANCE REQUIRED PRESSURE AND
FLOWS PER MANUFACTURERS RECOMMENDATIONS.
PROVIDE AND INSTALL BRASS VALVE TAGS ON ALL
REGULATORS STAMPED WITH THE SET PRESSURE AS
DICTATED BY THE APPLIANCE MANUFACTURER.
WATER COPPER TUBING (BELOW SLABS AND EXTERIOR): ASTM B
88 TYPE 'K' SOFT WATER TUBE ANNEAL TEMPERED. NO
JOINTS PERMITTED BELOW GROUND.
WATER COPPER TUBING (INSIDE BUILDING): ASTM B 88, TYPE 'L'
HARD WATER TUBE DRAWN TEMPER. WITH CAST-COPPER
SOLDER-JOINT FITTINGS: ANSI B16.18. OR
WROUGHT-COPPER SOLDER JOINT FITTINGS: ANSI B16.22
OR 200 PSIG, 250 °F PRESS FIT FITTINGS TO ASTM B75, AND
ASME B16/51 PERFORMANCE.
WATER WHERE INDICATED ON THE PLANS, WATER TUBING SHALL
BE TYPE A PEX WIRSBO, ZURN, NIBCO, OR UPONOR
CONFORMING TO ASTM F876, F877, E84, E814, ANSI/UL 263
AND NSF14/61. 100 PSIG AT 180 DEG. BLUE FOR COLD AND
RED FOR HOT AND RE-CIRCULATION WHITE FOR GENERIC.
FITTINGS SHALL BE PER ASTM F1960 LIKE UPONOR ProPEX
COLD EXPANSION, PRESS FIT MECHANICAL JOINTS PER
ASTM F2854 OR COPPER CRIMP WITH BRASS OR
ENGINEERED PLASTIC FITTINGS. MANIFOLDS WHERE USED
SHALL BE LIKE UPONOR ProPEX TYPE L TO ASTM F877
WITH BRASS OR EP BALL VALVES.
WATER BUILDING MAINS AND RISERS OUTSIDE OF WATER ROOM 2"
AND SMALLER: FLOW GUARD GOLD OR EQUAL SDR 11
CPVC; PIPING ASTM D 2846 WITH SOCKET WELDED
FITTINGS ASTM F 493. MADE FROM CPVC CELL CLASS
24448 ASTM D 1784. MANUFACTURED PER NSF 14 AND 61.
SEWER/VENT POLYVINYL CHLORIDE SEWER PIPE (PVC): ASTM D2665,
ASTM F 1866 SCHEDULE 40 SOLID CORE DRAIN WASTE AND
VENT WITH PVC SOCKET WELDED FITTINGS DESIGNED TO
FIT PIPING DIAMETERS. ALL PIPING IN RETURN AIR
PLENUMS SHALL CONFORM TO REQUIREMENTS FOR
PLENUM MATERIALS.
PLUMBING INSULATION
1. ALL PIPING INSULATION MATERIALS SHALL HAVE A FLAME SPREAD
RATING OF 25 OR LESS (ON THE FLAME SPREAD TEST SCALE) AND
SMOKE DEVELOPMENT OF 50 OR LESS (ON THE SMOKE TEST SCALE)
OR AS DEFINED BY NFPA 255 STANDARD METHOD OF TESTING OF
SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS,
LOCAL CODES AND LOCAL AUTHORITIES HAVING JURISDICTION. ALL
PVC PIPING LOCATED IN RETURN AIR PLENUM SPACES OR EXPOSED
SHALL BE INSULATED.
2. INSTALL ALL INSULATION IN STRICT ACCORDANCE WITH
MANUFACTURERS INSTRUCTIONS IN A TIGHT AND NEAT MANOR. NO
SAGGING, FRAYED OR TORN INSULATION WILL BE EXCEPTED.
3. ALL INSULATION R-VALUES SHALL MEET THE CURRENT ENERGY
CODE REQUIREMENTS. UNLESS OTHERWISE NOTED ON PLANS
PIPING SYSTEMS SHALL BE INSULATED AS FOLLOWS:
a. HOT WATER RE-CIRCULATION SYSTEMS; ALL HW AND HWR
PIPING SHALL BE INSULATED
b. NON RE-CIRCULATION HOT WATER STORAGE SYSTEMS; THE
FIRST 8 FEET OF HW AND CW PIPING CONNECTED TO THE
STORAGE TANK.
c. COPPER WATER PIPING; ALL PIPING HOT OR COLD SHALL BE
INSULATED.
d. HEAT TRACED PIPING; ALL HEAT TRACED SECTIONS.
e. PLASTIC PIPING BELOW GRADE; ALL HW, CW, HWR PIPING.
EXCEPTIONS: THE TUBING FROM THE CONNECTION AT THE
TERMINATION OF THE FIXTURE SUPPLY PIPING TO A PLUMBING
FIXTURE OR PLUMBING APPLIANCE.PIPING FROM
USER-CONTROLLED SHOWER AND BATH MIXING VALVES TO THE
WATER OUTLETS.
4. STORM WATER PIPING EXPOSED IN BUILDING SHALL BE INSULATED
FOR SOUND WITH MINIMUM 1
2" THICK ELECTROMETRIC CLOSED CELL
INSULATION.
5. INSULATION MATERIALS:
a. PRE-FORMED TYPE I, 850 DEG F MINERAL OR GLASS FIBERS
BONDED WITH A THERMOSETTING RESIN AND HINGED WITH
SELF SEALING LAP. COMPLY WITH ASTM C 547, TYPE I,
GRADE A, WITH FACTORY-APPLIED ASJ.
b. FLEXIBLE ELASTOMERIC CLOSED CELL OR EXPANDED
RUBBER PIPE INSULATION WITH PRESSURE SENSITIVE
ADHESIVE SYSTEM, ASTM C534, ASTM E84 CLASS A 300 DEG F.
c. EXTERIOR/EXPOSED JACKETS: UV RESISTANT PVC PIPE
JACKETS AND PREFORMED FITTING COVERS COMPLIANT
WITH ASTM D257, D638, D790, D792, D1784, D3679, E84 AND
E136.
FIRE STOPPING.
a. FIRE STOPPING SYSTEMS SHALL BE IN FULL COMPLIANCE
WITH SECTIONS 714 OF THE IBC AND SECTION 315 OF THE
IPC.
b. CONTRACTOR SHALL MAKE REFERENCE TO ARCHITECTURAL
PLANS AND PROVIDE ALL REQUIRED FIRE STOPPING
SYSTEMS.
c. CONTRACTOR SHALL PROVIDE AHJ WITH FULL SUBMITTAL
INDICATING METHODS OF CONSTRUCTION AND UL LISTINGS
FOR EACH REQUIRED FIRE STOP SYSTEM.
d. ACCESS DOORS REQUIRED IN CEILINGS OF
FIRE-RESISTANCE-RATED FLOOR/CEILING AND ROOF/CEILING
ASSEMBLIES SHALL BE TESTED IN ACCORDANCE WITH ASTM
E 119 OR UL 263 AS HORIZONTAL ASSEMBLIES AND LABELED
BY AN APPROVED AGENCY FOR SUCH PURPOSE.
CHECK TEST AND START UP REQUIREMENTS
1. PLUMBING CONTRACTOR SHALL FURNISH ALL TOOLS, INSTRUMENTS
AND EQUPMENT REQUIRED FOR TESTING PIPING. ALL TESTING
SHALL BE DONE PRIOR TO CONCEALMENT. ALL PARTS OF THE
SANITARY DRAINAGE SYSTEM SHALL BE TESTED AS REQUIRED BY
LOCAL PLUMBING INSPECTORS. ALL WATER PIPING SHALL BE
HYDROSTATICALLY TESTED TO MINIMUM 125 PSIG.
2. CLOSE OUT: PROVIDE MANUFACTURERS OPERATION AND
MAINTENANCE MANUALS AND AS BUILT DRAWINGS. PROVIDE (1)
TRAINING SESSION TO OWNER SELECTED PERSONNEL AS
REQUESTED AND PROVIDE WARRANTY INFORMATION FOR ALL
MANUFACTURERS WARRANTED EQUIPMENT
3. FILL SYSTEMS WITH FRESH WATER AND INSPECT ALL CONNECTIONS
FOR LEAKAGE. REMOVE ALL PACKING AND PROTECTIVE SHIPPING
MATERIALS. CLEAN ALL FIXTURES AND START-UP ALL WATER
HEATERS, PUMPS, AND EQUIPMENT. VERIFY PROPER OPERATION.
OPERATE ALL FAUCETS AND INSPECT STOPS, RISERS, TRAPS AND
DRAINS. CORRECT ALL LEAKS, WATER HAMMER AND VIBRATIONS AS
REQUIRED.
AFF ABOVE FINISHED FLOOR
BTUH BRITISH THERMAL UNIT PER HOUR
CA COMBUSTION AIR
CO CLEAN OUT
CW COLD WATER
EC ELECTRICAL CONTRACTOR
FD FLOOR DRAIN
FT FEET
GC GENERAL CONTRACTOR
GM GAS METER
GPM GALLONS PER MINUTE
HW HOT WATER
IN INCH
LAV LAVATORY
MAN MANUAL
MFR MANUFACTURER
MC MECHANICAL CONTRACTOR
MS MOP SINK
PC PLUMBING CONTRACTOR
PD PRESSURE DROP
PRV PRESSURE RELIEF VALVE
PSI POUNDS PER SQUARE INCH
RPM REVOLUTIONS PER MINUTE
RPZB REDUCED PRESSURE ZONED BACKFLOW
SAN SANITARY SEWER
SK SINK
TD TRENCH DRAIN
TMV THERMAL MIXING VALVE
UON UNLESS OTHERWISE NOTED
VIF VERIFY IN FIELD
VTR VENT THORUGH ROOF
WC WATER CLOSET
WH WATER HEATER
PLUMBING
ABBREVIATIONS,
SYMBOLS, &
SPECIFICATIONS
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
07/14/21
P002
PLUMBING
DETAILS, AND
SCHEDULES
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
ROOF LINE
MIRO PIPE STAND
ELBOW
ELBOW
REDUCER
UNION
APPLIANCE4" DIRT LEGWITH CAP
(IF NECCESARY)
FIELD VERIFY LENGTH
AGA RATED GAS STOP
GAS CONNECTION DETAIL
ROOF GAS PIPING SUPPORT DETAIL
MIRO #1.5 PIPE SUPPORT
W/ ACCESSORIES
ACCESSORIES
- 1.5 pipe guide
- 1.5 spacer
- Support pad
- Eternabond } 2-sided tape
FLOW TEST DATA
WATER SUPPLY TEST & GRAPH E
60 psi
56 psi
1000 gpm
8/4/20
300100 400 500 600 700 800 900 1000200
600200 800 1000 1200 1400 1600 1800 2000400
1200400 1600 2000 2400 700 800 900 1000800
FLOW RATE GPM
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
PRESSURE PSIGPICK X AXIS SCALE AS NEEDED
S.S. CLAMPING RING
NON-INSULATED PIPE
SEALANT IN PIPE SLEEVE
URETHANE OR DOW CORNING
1/2" (MIN.) FOAM-IN-PLACE
RESILIENT FOAM PENETR.
#3-6548 SILICONE RTV
NON-INSULATED PIPE
EPDM FLASHING BOOT
WIRE MESH
STAINLESS STEEL
1/4"x1/4"
VENT THRU ROOF DETAILSNOW LOADING HGT. RQMTS.EXTEND VENTING PERCLEANOUT DETAIL
HW CW
EWH
VALVE
TANK DRAIN
2" DRAIN PAN
TERMINATE RELIEF
OVER DRAIN PAN
SHELF MOUNTED WATER HEATER
INSULATED 3/4"
HW SUPPLY
WATER HEATER DETAIL
TMV
THERMOSTATIC
MIXING VALVE COLD WATER
EXPANSION TANK
FACTORY SUPPLIED HEAT
TRAP NIPPLES
TYPICAL
110 DEG. WATER
TEMPERATURE GAGE
LOCATION
AT FLOOR DRAIN
TERMINATE 3/4" DRAIN
3/4"
MOP SINK
(ATTACH SHELF TO STRUCTURE ABOVE)
+7'-6"AFF
FLOOR DRAIN
ASME TEMPERATURE
RELIEF VALVE
AND PRESSURE
147 & 155 WEST CARMEL
DRIVE CARMEL, INDIANA
CARMEL WATER
DEPARTMENT
STATIC
PRESSURE
RESIDUAL
PRESSURE
FLOW RATE
GPM
PERFORMED
BY:
DATE:
LOCATION:
M.J. X FL. ADAPTER
ALL THR. ROD
WASHER
TIE BOLT
"J" BOLT OR
HEX NUT &
THRUST BLOCK
(PER NFPA 24)
FLOOR
D.I.P. RISER
BY OTHERS
SLEEVE AND SEAL
SLAB PENETRATION
PER NFPA 13
U.G. PIPING TO 5 FEET PAST FOUNDATION
SEE CIVIL PLAN FOR CONTINUATION
FIRE SPRINKLER
SERVICE DETAILF G H
A C DNO SCALE
NO SCALE NO SCALE
NO SCALE
NO SCALE NO SCALE
BUILDING ISOMETRIC DIAGRAM
NO SCALE1
MS
3"VTR FD
LAV
WC
SK
3"W
SEE CIVIL
SHEETS FOR
CONTINUATION 1-1
/
2"V
2"
V
2"V
2"V
3"W
3"
W
3"W
3"
W
GCO
2"W
CO 3"W
3"VTR
2"VCO
CO
DETAIL IS FOR REFERENCE ONLY, PROR TO
INSTALLATION, COORDINATE INSTALLATION WITH SITE
CONTRACTOR AND LOCAL WATER UTILITY.
SYSTEM
TO DOMESTIC
3/4"
INLET
CARMEL WATER SERVICE DETAIL - 3/4"
SCALE: NONE
3/4"
CARMEL WATER 3/4" REMOTE
READ METER WITH LOCKABLE
VALVES. COORDINATE WITH
PUBLIC UTILITY.
SECURE ALL PIPING, FITTINGS
AND VALVES TO WALL OR
FLOOR PER SPECIFICATIONS.
B
18"
REDUCED PRESSURE ZONE
BACKFLOW PREVENTER:
WATTS MODEL 009M2QTS
CAST BRONZE
CONSTRUCTION WITH
QUARTER TURN FULL-PORT
BALLVALVES.
30"RISING STEM
BALL VALVES 3/4"
3/4"
FLOOR DRAIN
1 10/15/20BID ADDEN. 002
1
07/14/21
UP
A
1
A.1 B B.1 C C.1 D
2
3
4
5
6
7
8
9
10
11
12
13
1414
15
16
OFFICE
101
ELEC.
106
STAIR
108
SPRINKLER
107
ELEV.
109
TELECOM
103
STORAGE
UNITS
100
CONC
P2 1
CORRIDOR
110
BREAKROOM
102 WC
105JANITOR
104
100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10197 SF10 x 2024 SF5 x 549 SF10 x 5147 SF10 x 15147 SF10 x 15145 SF10 x 1573 SF10 x 7.573 SF10 x 7.573 SF10 x 7.572 SF10 x 7.536 SF5 x 7.549 SF10 x 549 SF10 x 599 SF10 x 1099 SF10 x 1049 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 5153 SF10 x 15 153 SF10 x 15151 SF10 x 1549 SF10 x 599 SF10 x 1024 SF5 x 5147 SF10 x 1573 SF10 x 7.573 SF10 x 7.573 SF10 x 7.549 SF10 x 549 SF10 x 5SAN SAN SAN SAN SAN3"W
SEE CIVIL SHEETS
FOR CONTINUATION
SAN SAN SAN SAN
FD
SAN SAN SAN SAN
WH
SANMS
LAV
WC
3"W
GCO
FD
SK
3"W
3"W
2"W
F-1
EXISTING SANITARYSAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN3"WCO
CO
3"W 3"WFFE = 829.86
IE = 824.36
CO
2"V UP
THRU
ROOF
15
16
17
A A.1 B B.1 C C.1 D
32
18
19
20
21
22
23
24
25
26
27
28
29
30
31
STAIR
111
STORAGE
UNITS
100
CONC
P2 1
VESTIBULE
112100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1049 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 599 SF10 x 1099 SF10 x 10252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25153 SF10 x 15 153 SF10 x 15252 SF10 x 25249 SF10 x 25253 SF10 x 25157 SF10 x 1598 SF10 x 1049 SF10 x 549 SF10 x 599 SF10 x 1049 SF10 x 524 SF5 x 549 SF10 x 5252 SF10 x 25252 SF10 x 25252 SF10 x 2524 SF5 x 549 SF10 x 549 SF10 x 5100 SF10 x 10CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CWCW CW CW CW
CW CW CW HB-23/4"CWP100
FIRST FLOOR
WASTE PLAN
1. REFERENCE SHEET P001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
2. REFERENCE SHEET P002 FOR SCHEDULES,
DETAILS, AND BUILDING ISOMETRIC DIAGRAM.
3. EXISTING PLUMBING ELEMENTS SHOWN ON
THESE PLANS IS BASED ON LIMITED SURVEY
INFORMATION. P.C. SHALL REVIEW ALL PLANS
AND SPECIFICATIONS, VISIT SITE AND INCLUDE
IN BID ALL WORK AS NEEDED TO MEET DESIGN
INTENT.
GENERAL NOTES:
N
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
1 SCALE: 1/8" = 1'-0"
FIRST FLOOR WASTE PLAN AREA A 2 SCALE: 1/8" = 1'-0"
FIRST FLOOR WASTE PLAN AREA B
MATCH LINE A-A MATCH LINE A-A
MATCH LINE A-A MATCH LINE A-A
11
1 10/15/20BID ADDEN. 002
07/14/21
UP
A
1
A.1 B B.1 C C.1 D
2
3
4
5
6
7
8
9
10
11
12
13
1414
15
OFFICE
101
ELEC.
106
STAIR
108
SPRINKLER
107
ELEV.
109
TELECOM
103
STORAGE
UNITS
100
CONC
P2 1
CORRIDOR
110
BREAKROOM
102 WC
105JANITOR
104
100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10197 SF10 x 2024 SF5 x 549 SF10 x 5147 SF10 x 15147 SF10 x 15145 SF10 x 1573 SF10 x 7.573 SF10 x 7.573 SF10 x 7.572 SF10 x 7.536 SF5 x 7.549 SF10 x 599 SF10 x 1049 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 5153 SF 10 x 15151 SF10 x 1549 SF10 x 599 SF10 x 1024 SF5 x 5147 SF10 x 1573 SF10 x 7.573 SF10 x 7.573 SF10 x 7.549 SF10 x 549 SF10 x 5CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CWCW
GAS GAS GAS GAS GAS GAS GAS GASGAS
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GASHB-2
CW CWCW CW CW CW
CW CW CW
WHMS
LAV
WC
GAS
METER
SK HWS HWSHWS HWS HWS HWS
CW
2-1/2" GAS
UP TO
SECOND
FLOOR
3/4"CW3/4"CW F-1
3/4"CW
3/4"CW
1/2"3/4"CW1/2"CW
GAS
1"G
FP FP FP
6"FP
2-1/2"G 2-1/2" GAS
CW CW CW CW CW CW CW CW
CW CW CW CW CW CW3/4"CW 2-1/2"G100 SF10 x 10100 SF10 x 10100 SF10 x 1024 SF5 x 549 SF10 x 549 SF10 x 599 SF10 x 1099 SF10 x 10153 SF10 x 15153 SF10 x 15253 SF10 x 2549 SF10 x 5100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1049 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 599 SF10 x 1099 SF10 x 10252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25153 SF10 x 15153 SF10 x 15252 SF10 x 25249 SF10 x 25253 SF10 x 25157 SF10 x 1598 SF10 x 1049 SF10 x 549 SF10 x 599 SF10 x 1049 SF10 x 524 SF5 x 549 SF10 x 515
16
17
A A.1 B B.1 C C.1 D
32
18
19
20
21
22
23
24
25
26
27
28
29
30
31
STAIR
111
STORAGE
UNITS
100
CONC
P2 1
111 EX111 VESTIBULE
112
EX112
112100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1049 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 599 SF10 x 1099 SF10 x 10252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25153 SF10 x 15 153 SF10 x 15252 SF10 x 25249 SF10 x 25253 SF10 x 25157 SF10 x 1598 SF10 x 1049 SF10 x 549 SF10 x 599 SF10 x 1049 SF10 x 524 SF5 x 549 SF10 x 5252 SF10 x 25252 SF10 x 25252 SF10 x 2524 SF5 x 549 SF10 x 549 SF10 x 5100 SF10 x 10CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CWCW CW CW CW
CW CW CW HB-23/4"CWP101
FIRST FLOOR
WATER PLAN
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
1 SCALE: 1/8" = 1'-0"
FIRST FLOOR PLUMBING PLAN AREA A 2 SCALE: 1/8" = 1'-0"
FIRST FLOOR PLUMBING PLAN AREA B
MATCH LINE A-A MATCH LINE A-A
MATCH LINE A-A MATCH LINE A-A
N
PROVIDE AND INSTALL 1,000 MBH, 7" W.C. GAS
SERVICE AND 2-1/2" LINE FROM GAS METER UP TO
ROOF TO SERVE ROOFTOP UNITS.
a. (2) ROOFTOP UNIT 400 EACH 800 MBH
b. (1) GAS-FIRED FURNACE 60 MBH
c. NOT USED 0 MBH
TOTAL 860 MBH
3/4" DOMESTIC WATER SERVICE. SEE CIVIL SHEETS
FOR CONTINUATION.
ROUTE 3/4"CW TO WATER HEATER AND 3/4"HW
FROM WATER HEATER TO PLUMBING FIXTURE AS
REQUIRED.
ROUTE 1" GAS LINE UP TO ROOF TO SERVE
ROOFTOP UNITS.
ROUTE 3/4" GAS LINE TO GAS-FIRED FURNACE, SEE
SHEET P002 GAS CONNECTION AND DIRT LEG
DETAIL.
6" FIRE SERVICE LINE, SEE CIVIL SHEETS FOR
CONTINUATION.
PROVIDE 3/4" SHUT-OFF VALVE DRAINABLE TYPE
FOR HOSE BIB LOCATED ON THIRD FLOOR LEVEL.
KEY NOTES:
1
1. REFERENCE SHEET P001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
2. REFERENCE SHEET P002 FOR SCHEDULES AND
DETAILS.
GENERAL NOTES:
2
3
4
1
2
3
4
5
5
6
6
7
7
1
1 10/15/20BID ADDEN. 002
1
1
1
1
1
1
07/14/21
DN
UP
A
1
A.1 B B.1 C C.1 D
2
3
4
5
6
7
8
9
10
11
12
13
14
15
ELEV.
202
STAIR
201
STORAGE
UNITS
200
CONC
P2 1
ENCLOSED SOFFIT
SPACE102 SF10 x 10102 SF10 x 1099 SF10 x 10150 SF10 x 15100 SF10 x 10100 SF10 x 10100 SF10 x 10154 SF10 x 15102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10187 SF10 x 18.599 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF 10 x 1099 SF10 x 1099 SF10 x 1049 SF10 x 5134 SF10 x 13.5147 SF10 x 15145 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15148 SF10 x 15148 SF10 x 1549 SF10 x 549 SF10 x 549 SF10 x 5199 SF10 x 2049 SF10 x 549 SF10 x 525 SF5 x 599 SF10 x 1099 SF10 x 1099 SF10 x 10102 SF10 x 10102 SF10 x 10149 SF10 x 15149 SF10 x 15134 SF10 x 13.5149 SF10 x 1549 SF10 x 599 SF10 x 102-1/2"GAS FROM
FIRST FLOOR AND
1" GAS UP TO ROOF
3/4"CW
DOWN
CW CW CW CW
3/4"CW
UP
15
32
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
STAIR
203
STORAGE
UNITS
200
CONC
P2 1
ENCLOSED SOFFIT
SPACE
104 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 10102 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10199 SF10 x 20199 SF10 x 2099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10199 SF10 x 20199 SF10 x 20199 SF10 x 20199 SF10 x 20199 SF10 x 20199 SF10 x 20199 SF10 x 20199 SF10 x 2099 SF10 x 1099 SF10 x 10199 SF10 x 20199 SF10 x 20156 SF10 x 1549 SF10 x 524 SF5 x 549 SF10 x 524 SF5 x 5149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15102 SF10 x 10102 SF10 x 10102 SF10 x 10149 SF10 x 15102 SF10 x 10P200
SECOND FLOOR
PLUMBING
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
1 SCALE: 1/8" = 1'-0"
SECOND FLOOR PLUMBING PLAN AREA A 2 SCALE: 1/8" = 1'-0"
SECOND FLOOR PLUMBING PLAN AREA B
MATCH LINE A-A MATCH LINE A-A
MATCH LINE A-A MATCH LINE A-A
N
CONTINUE 1" GAS LINE FROM FIRST FLOOR UP TO
ROOF TO SERVE ROOFTOP UNITS.
NOT USED
ROUTE 3/4"CW AS HIGH AS POSSIBLE UP TO
THIRD FLOOR AS REQUIRED.
KEY NOTES:
1
1. REFERENCE SHEET P001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
2. REFERENCE SHEET P002 FOR SCHEDULES AND
DETAILS.
GENERAL NOTES:
1
2
3
1
1
3
1
1 10/15/20BID ADDEN. 002
07/14/21
DN
A
1
A.1 B B.1 C C.1 D
2
3
4
5
6
7
8
9
10
11
12
13
14
15
ELEV.
302
STAIR
301
STORAGE
UNITS
300
15102 SF10 x 10102 SF 10 x 1099 SF10 x 10150 SF7.5 x 12.599 SF10 x 1099 SF10 x 1099 SF10 x 10153 SF7.5 x 12.549 SF10 x 5102 SF10 x 10102 SF10 x 10102 SF10 x 10103 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF 10 x 1099 SF10 x 1099 SF10 x 10148 SF10 x 13.5139 SF10 x 13.5134 SF10 x 13.5141 SF10 x 13.5147 SF10 x 15145 SF10 x 15149 SF10 x 1549 SF10 x 549 SF 10 x 549 SF10 x 598 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1049 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 5149 SF10 x 1599 SF10 x 1020 SF5 x 320 SF5 x 3102 SF10 x 10102 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10102 SF10 x 1099 SF10 x 1049 SF10 x 549 SF10 x 549 SF10 x 5HB-1
2-1/2" GAS
UP/DOWN
15
32
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
STAIR
303
STORAGE
UNITS
300 99 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 1599 SF10 x 1099 SF10 x 1099 SF10 x 10149 SF10 x 15150 SF10 x 1591 SF10 x 10149 SF10 x 15154 SF10 x 15149 SF10 x 15149 SF10 x 1549 SF10 x 549 SF10 x 549 SF10 x 5149 SF10 x 15P300
THIRD FLOOR
PLUMBING
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
1 SCALE: 1/8" = 1'-0"
THIRD FLOOR PLUMBING PLAN AREA A 2 SCALE: 1/8" = 1'-0"
THIRD FLOOR PLUMBING PLAN AREA B
MATCH LINE A-A MATCH LINE A-A
MATCH LINE A-A MATCH LINE A-A
N
CONTINUE 1" GAS LINE FROM FIRST FLOOR UP TO
ROOF TO SERVE ROOFTOP UNITS.
PROVIDE BALL VALVE AND HOSE BIB
APPROXIMATELLY 18" A.F.F.
KEY NOTES:
1
1. REFERENCE SHEET P001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
2. REFERENCE SHEET P002 FOR SCHEDULES AND
DETAILS.
GENERAL NOTES:
1
2
2
1
1
1 10/15/20BID ADDEN. 002
07/14/21
A
1
A.1 B B.1 C C.1 D
2
3
4
5
6
7
8
9
10
11
12
13
14
1515GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GASRTU-1
400 MBH
GAS GAS
2"GGAS GAS GAS GAS GAS 2-1/2" GAS
FROM
BELOW
2-1/2" GAS
2"G
15
A A.1 B B.1 C C.1 D
32
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GASGAS GAS
RTU-2
400 MBH2"G2"G
P400
ROOFTOP
PLUMBING PLAN
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
1 SCALE: 1/8" = 1'-0"
ROOFTOP PLUMBING PLAN AREA A 2 SCALE: 1/8" = 1'-0"
ROOFTOP PLUMBING PLAN AREA B
MATCH LINE A-A MATCH LINE A-A
MATCH LINE A-A MATCH LINE A-A
N
CONNECT GAS LINE TO EQUIPMENT WITH AGA
SHUT OFF, DIRT LEG AND UNION. COORDINATE
WITH LOCAL GAS UTILITY AND EQUIPMENT
SUPPLIERS. SEE GAS CONNECTION DETAIL ON
SHEET P002.
KEY NOTES:
1
1. REFERENCE SHEET P001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
2. REFERENCE SHEET P002 FOR SCHEDULES AND
DETAILS.
GENERAL NOTES:
1
1
1 10/15/20BID ADDEN. 002
11
1
1
1
1
1
07/14/21
E001
DOOR ALARM CONTROL PANEL DACP
HINGE SIDE PLUNGER SWITCH DC
FIRE PROTECTION SYMBOLS
FIRE ALARM CONTROL PANEL FACP
FFIRE PULL BOX
HORN/STROBE ALARM COMBO
SSTROBE
FSFLOW SWITCH
TSPIV TAMPER SWITCH
HORN/STROBE ALARM COMBO WEATHER PROOF
AHOOD ANSUL SYSTEM CONNECTION
SSMOKE DETECTOR
DUCT SMOKE DETECTOR S
HEAT DETECTOR H
SD
MAGNETIC LOCK WITH KEY PAD
MAGNETIC LOCK WITH CARD READER
HS
KP
CR
CARBON MONOXIDE DETECTOR CO
ELECTRICAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS
1. BID INSTRUCTIONS: CONTRACTORS SHALL PROVIDE BASE
BID IN STRICT ACCORDANCE WITH DESIGN BASIS
EQUIPMENT AND MATERIALS. PROJECT DOES ENCOURAGE
COMPETITIVE PRICING AND ALLOWS FOR SUBSTITUTIONS
OF EQUAL EQUIPMENT AND MATERIALS AGAINST THE BASIS
OF DESIGN. SUBSTITUTE ITEMS WILL BE COMPARED
AGAINST DESIGN BASIS DURING SUBMITTAL PROCESS.
ENGINEER RESERVES THE RIGHT TO REJECT
SUBSTITUTIONS FOUND NOT TO BE EQUAL TO ITEMS
LISTED IN DESIGN BASIS..
2. PRIOR TO PROCUREMENT CONTRACTOR SHALL SUBMIT TO
ARCHITECT FULL SUBMITTALS FOR ALL ENERGY
CONSUMING OR PRODUCING ITEMS AND FOR ALL SWITCH
GEAR, LOAD CENTERS AND PANEL BOARDS. SUBMITTALS
SHALL BE DELINEATED WITH TAGS INDICATED ON PRINTS,
CONTRACTORS NAME AND PROJECT NAME. CLEARLY
INDICATE ALL MODEL NUMBERS AND ALL ACCESSORIES
AND OPTIONS BEING PROVIDED. SUBMISSIONS SHALL BE IN
PDF FORMAT. ALL EQUIPMENT AND ITEMS SHALL BE PER
DESIGN BASIS OR APPROVED EQUAL. ENGINEER RESERVES
THE RIGHT TO REJECT ANY SUBSTITUTE ITEM FOUND NOT
EQUAL TO THE SPECIFIED ITEM AS DESIGNED.
3. CONTRACTOR SHALL FURNISH A TEMPORARY SERVICE FOR
THE USE OF ALL TRADES DURING CONSTRUCTION AS
REQUIRED BY THE GENERAL CONTRACTOR. REMOVE ALL
TEMPORARY EQUIPMENT AS PERMANENT SERVICES
BECOME AVAILABLE.
4. THE DRAWINGS IN THIS SECTION ARE DIAGRAMMATIC AND
ARE NOT INTENDED TO DEFINE EXACT QUANTITIES,
LOCATIONS OR CODIFIED REQUIREMENTS. DRAWINGS
SHOW GENERAL INTENT OF SYSTEMS. MODIFICATIONS IN
ELECTRICAL SYSTEM ROUTING AND LOCATIONS AS
REQUIRED TO MEET THE INTENT, SHALL BE PERFORMED
WITHOUT ADDITIONAL COST TO OWNER. SECURE AND PAY
FOR ALL REQUIRED PERMITS.
5. THE ELECTRICAL CONTRACTOR IS TO PROVIDE ALL
REQUIRED LABOR, MATERIALS, EQUIPMENT, AND
CONTRACTOR'S SERVICES NECESSARY TO COMPLETE THE
INSTALLATION OF SYSTEMS REQUIRED IN FULL
CONFORMITY WITH APPLICABLE CODES AND ORDINANCES.
THE FINISHED JOB SHALL BE FUNCTIONAL AND COMPLETE
IN EVERY DETAIL INCLUDING ANY AND ALL SUCH ITEMS FOR
A COMPLETE SYSTEM. CONTRACTOR SHALL GUARANTEE
ALL LABOR AND MATERIALS ENTERING INTO CONTRACT
FOR A PERIOD OF ONE (1) YEAR FROM DATE OF
ACCEPTANCE.
6. ALL WORK SHALL IN BE IN FULL ACCORDANCE WITH 2009
INDIANA ELECTRICAL CODE (2008 NFPA 70), 2010 INDIANA
ENERGY CODE (ASHRAE 90.1-2007), PERTINENT STATE,
COUNTY, CODES AND ORDINANCE AND INDIANA
AMENDMENTS. COORDINATE WORK WITH OTHER TRADES.
ELECTRICAL CONTRACTOR SHALL BEAR ALL COSTS
RESULTING FROM ANY NON COMPLIANCE WITH CODE
REQUIREMENTS.
7. MATERIALS AND EQUIPMENT SHALL BE NEW UNLESS
INDICATED OTHERWISE. MATERIAL SHALL BEAR U.L. LABEL
WHERE SUCH STANDARDS HAVE BEEN ESTABLISHED AND
LISTED BY U.L. MATERIALS AND EQUIPMENT SHALL
CONFORM WITH THE LATEST ISSUES OF APPLICABLE
TECHNICAL STANDARDS.
8. THE ELECTRICAL CONTRACTOR IS TO PROVIDE A
COMPLETE SYSTEM OF LIGHTING, RECEPTACLES, AND
POWER AS REQUIRED. VERIFY ALL VOLTAGES AND PHASE
REQUIREMENTS WITH MECHANICAL CONTRACTOR'S
EQUIPMENT PRIOR TO PERFORMING ANY WORK.
9. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND
VERIFY ALL EXISTING CONDITIONS BEFORE SUBMITTING A
BID. NO EXTRAS WILL BE ENTERTAINED FOR
CONTRACTORS FAILURE TO IDENTIFY EXISTING
CONDITIONS AND ADJUST AS REQUIRED TO MEET DESIGN
INTENT.
10. ALL CONDUIT COUPLINGS AND CONNECTIONS SHALL BE
COMPRESSION TYPE AND MADE TO ENSURE POSITIVE
GROUNDING CONTINUITY. MAKE CONNECTIONS TO
EQUIPMENT SUBJECT TO VIBRATION WITH 18 INCHES OF
FLEXIBLE WATERTIGHT CONDUIT WITH WATERTIGHT
FITTINGS. PROVIDE FOR SUPPORT AND SECURING OF ALL
CONDUIT AND EQUIPMENT. CONNECTIONS TO LIGHTING
FIXTURES SHALL BE MADE WITH SIX (6) FEET OF FLEXIBLE
CONDUIT FROM A BOX WITHIN TWO (2) FEET OF THE
FIXTURE. SPLICE ALL WIRES ONLY IN ACCESSIBLE BOXES.
ALL FIXTURE WHIPS TO BE FLEXIBLE METAL CONDUIT 1/2"
MINIMUM SIZE WITH COMPRESSION CONNECTORS WITH
INSULATED THROATS. WHIPS SHALL NOT EXCEED 6'.
FIXTURE WHIPS TO BE SUPPORTED FROM BUILDING
STRUCTURE.
WIRING AND RACEWAYS
1. ALL LIGHTING AND BRANCH CIRCUIT WIRING SHALL BE
SOLID COPPER MINIMUM SIZE #12 AWG. 600V INSULATION,
75 DEG. C., TYPE THW OR THWN, NOT LESS THAN #12 AWG.
ALL WIRE SERVING AS FEEDS TO DISTRIBUTION PANEL
BOARDS OR INTEGRAL HORSEPOWER MOTORS SHALL BE
EITHER STRANDED COPPER CONDUCTOR OR ASTM B800
ALUMINUM AA-8000 SERIES. THESE SHALL BE SIZED NOT
LESS THAN #10 AWG FOR COPPER AND NOT LESS THAN #8
AWG FOR ALUMINUM. EACH WITH MINIMUM 600V THW OR
THWN INSULATION, 75 DEG. C. ALL FEEDER SHALL BE
SIZED IN ACCORDANCE WITH NEC 310.15.
2. EXPOSED WIRING SHALL BE IN EMT RACEWAY. EXTERIOR
WIRING SHALL BE IN CONDUIT. CONCEALED WIRING SHALL
BE IN EMT OR METAL CLAD CABLE WHERE ALLOWED BY
CODE.
3. ALL LOW VOLTAGE WIRING IN PLENUM RATED CEILINGS OR
EXPOSED IN ROOMS SHALL BE PLENUM RATED CABLE.
4. ALL CABLE SHALL BE NEW WIRE OF RECENT
MANUFACTURE AND IN ACCORDANCE WITH THE LATEST
STANDARDS OF IPCEA AND NEMA AS A MINIMUM.
5. ALL DEVICES AND EQUIPMENT SHALL BE SOLIDLY
GROUNDED IN ACCORDANCE WITH NEC REQUIREMENTS.
6. ALL SOLID CONDUCTOR WIRES MAY BE TERMINATED
UNDER SCREW HEADS. STRANDED WIRES MAY BE
TERMINATED BY USING PUSH-IN CLAMP TYPE
CONNECTORS FURNISHED WITH DEVICES OR TERMINATED
WITH COMPRESSION TYPE TERMINAL LUGS. SET SCREW
TYPE TERMINATIONS ARE NOT PERMITTED.
7. NO MOTORS ARE TO BE SUPPLIED UNDER THIS CONTRACT
UNLESS ITEMS REQUIRING A MOTOR ARE FURNISHED BY
THIS CONTRACTOR. THE CONTRACTOR SHALL FURNISH
ALL STARTERS FOR ALL MOTORS REQUIRING A STARTER.
THE CONTRACTOR SHALL CONNECT ALL POWER
EQUIPMENT IF & WHERE SHOWN ON PLANS UNLESS
OTHER-WISE SPECIFIED & ASSURE OWNER THE MOTORS
ARE IN GOOD RUNNING ORDER.
8. E.C. SHALL PROVIDE ALL COMPONENTS NEEDED TO MEET
MEANS OF DISCONNECT PER N.E.C. FOR ALL HARD WIRED
EQUIPMENT.
PANELS AND DISCONNECTS
1. PANELBOARDS SHALL BE A DEAD-LOCK SAFETY TYPE,
SURFACE OR RECESSED MOUNTED AS SHOWN, EQUIPPED
WITH THERMAL-MAGNETIC MOLDED CASE CIRCUIT
BREAKERS WITH FRAME AND TRIP RATINGS AS REQUIRED.
TERMINALS FOR FEEDER CONDUCTORS TO THE
PANELBOARD MAINS AND NEUTRAL SHALL BE U.L. LISTED
AS SUITABLE FOR THE TYPE OF CONDUCTOR SPECIFIED.
TERMINALS FOR BRANCH CIRCUIT WIRING, BOTH BREAKER
AND NEUTRAL, SHALL BE U.L. LISTED AND CONNECTORS
SHALL BE OF THE FULL COMPRESSION TYPE.THE
PANELBOARD BUS ASSEMBLY SHALL BE ENCLOSED IN A
STEEL CABINET. THE SIZE OF THE WIRING GUTTERS AND
GAUGE OF STEEL SHALL BE IN ACCORDANCE WITH NEMA
STANDARD PUBLICATION NO. PB-1971 AND U.L.
STANDARDS NO. 67 FOR PANELBOARDS. CABINET SHALL
BE FABRICATED FROM GALVANIZED STEEL OR EQUIVALENT
RUST-RESISTANT STEEL. FRONTS SHALL INCLUDE DOORS
AND HAVE FLUSH, BRUSHED STAINLESS STEEL, CYLINDER
TUMBLER-TYPE LOCKS WITH CATCHES AND SPRING
LOADED DOOR PULLS. THE FLUSH LOCK SHALL NOT
PROTRUDE BEYOND THE FRONT DOOR. ALL PANELBOARD
LOCKS SHALL BE KEYED ALIKE. FRONTS SHALL HAVE
ADJUSTABLE INDICATING TRIP CLAMPS WHICH SHALL BE
CONCEALED WHEN THE DOORS ARE CLOSED. DOORS
SHALL BE MOUNTED BY COMPLETELY CONCEALED STEEL
HINGES. FRONTS SHALL NOT BE REMOVABLE WITH DOOR
IN THE LOCATED POSITION. A CIRCUIT DIRECTORY FRAME
AND TYPE WRITTEN CARD WITH A CLEAR PLASTIC
COVERING SHALL BE PROVIDED ON THE INSIDE OF THE
DOOR. THE DIRECTORY CARD SHALL PROVIDE A SPACE AT
LEAST 1/4" HIGH X 3" LONG OR EQUIVALENT FOR EACH
CIRCUIT. FRONTS SHALL BE OF CODE GAUGE, FULL
FINISHED STEEL WITH RUST-INHIBITING PRIMER FACTORY
FINISHED ENAMEL PAINT.
2. LOAD CENTERS SHALL BE UL LISTED AND MANUFACTURED
IN ACCORDANCE WITH THE LATEST NEMA STANDARDS.
CABINETS SHALL USE HINGED STYLE DOORS. MOUNT AT
6'-6" TO TOP OF CABINET.
3. CIRCUIT BREAKERS SHALL BE QUICK-MAKE, QUICK-BREAK,
THERMAL-MAGNETIC, TRIP INDICATING AND HAVE COMMON
TRIP ON ALL MULTI-POLE BREAKERS. BRANCH CIRCUIT
BREAKERS FEEDING CONVENIENCE OUTLETS SHALL HAVE
SENSITIVE INSTANTANEOUS TRIP SETTINGS OF NOT MORE
THAN 10 TIMES THE TRIP RATING OF BREAKER TO PREVENT
REPEATED ARCING SHORTS RESULTING FROM FRAYED
APPLIANCE CORDS. CONNECTION TO BUS SHALL BE BOLT
ON.
4. CONTRACTOR TO OBTAIN MAXIMUM FAULT CURRENT
AVAILABLE FROM THE UTILITY. CALCULATE THE FAULT
CURRENT AVAILABLE AT THE PANELS. ALL
PANELS/BREAKERS/SWITCHES ARE TO BE BRACED TO
EXCEED MAXIMUM AVAILABLE FAULT CURRENT AND
CIRCUIT BREAKERS ARE TO BE CAPABLE OF INTERRUPTING
FAULT CURRENT. MANUFACTURER SHALL PROVIDE ALL
REQUIRED FAULT CURRENT AND ARC-FLASH LABELING PER
110.16 AND 110.24.
5. MAXIMUM LOADING OF 20 AMP CIRCUITS SHALL NOT
EXCEED 1750 WATTS. VOLTAGE DROP OF BRANCH
CIRCUITS SHALL NOT EXCEED 3% AND FEEDER CIRCUITS
SHALL NOT EXCEED 2%. SEAL ALL PENETRATIONS
THROUGH WALLS, CEILINGS AND FLOORS AIR AND WATER
TIGHT. FIRE STOP WHERE REQUIRED.
6. CONTRACTOR SHALL PROVIDE ENGRAVED BAKELITE
NAMEPLATES FOR ALL ELECTRICAL PANELS AS REQUIRED
BY NEC 408.4(B) AND SHALL LABEL ALL DISCONNECTS,
TRANSFORMERS AND MOTORS OVER 1 HP. FURNISH
TYPEWRITTEN PANEL DIRECTORIES TO IDENTIFY ALL
ELECTRICAL CIRCUITS BOTH NEW AND EXISTING.
7. DISCONNECT SWITCHES SHALL BE GENERAL DUTY, NEMA
TYPE 1 FOR INDOOR SERVICE AND NEMA TYPE 3R FOR
OUTDOOR SERVICE, SUITABLE FOR PADLOCKING, NUMBER
OF POLES, RATINGS, FUSES (IF REQUIRED) SHALL BE AS
INDICATED ON THE DRAWINGS.
DEVICES
1. VERIFY EXACT LOCATION, COLOR AND HEIGHTS OF ALL
OUTLETS, RECEPTACLES, LIGHT FIXTURES AND EQUIPMENT
WITH OWNER'S REPRESENTATIVE PRIOR TO START OF
WORK. FURNISH GENERAL SERVICE DUPLEX'S, 15 AMP
SWITCHES, 15/20 AMP GFICS, HEAVY DUTY DISCONNECTS,
HVAC SSU SWITCHES, PANEL BOARDS, LOAD CENTERS,
DISTRIBUTION PANELS ETC. AS REQUIRED.
2. CONVENIENCE RECEPTACLES SHALL BE MOUNTED 18"
ABOVE FINISHED FLOOR (A.F.F.) TO BOTTOM UNLESS
NOTED OTHERWISE, SWITCHES AND PUSHBUTTONS SHALL
BE 42" A.F.F. TO BOTTOM UNLESS SPECIFIED OTHERWISE
ON THE DRAWINGS.
3. PRIOR TO ROUGH-IN E.C. SHALL VERIFY FINAL LOCATIONS
AND COLORS OF ALL DEVICES WITH OWNER.
4. INSTALL ALL DEVICES PARALLEL AND PERPENDICULAR TO
ADJACENT WALL AND CEILING, FLUSH WITH SURROUNDING
SURFACES AND FREE FROM ALL OBSTRUCTIONS.
REWORKING OF EQUIPMENT INSTALLED IMPROPERLY
SHALL BE AT THE CONTRACTOR'S EXPENSE.
5. SWITCHES, BOXES, ETC., SHALL BE NEMA TYPE 1
CONSTRUCTION FOR INDOOR APPLICATIONS AND NEMA
TYPE 3R CONSTRUCTION FOR OUTDOOR APPLICATIONS.
6. SWITCHES SHALL MEET NEMA STANDARDS, COLOR SHALL
BE BY ARCHITECT. SWITCHES SHALL BE EQUAL TO
HUBBELL COMMERCIAL SPECIFICATION GRADE 20/15
AMPERES, SINGLE POLE, 125/277V. MULTI-POLE OR
SPECIAL SWITCHING SHALL BE AS NOTED ON THE
DRAWINGS.
7. RECEPTACLES SHALL BE 125 VOLT, 15/20 AMPERES,
DUPLEX, GROUNDED HUBBELL COMMERCIAL
SPECIFICATION GRADE. SPECIAL RECEPTACLES SHALL BE
AS NOTED ON THE DRAWINGS.
8. MATCHING COVER PLATES SHALL BE PROVIDED FOR ALL
RECEPTACLES AND SWITCHES.
LIGHTING FIXTURES:
1. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING
FIXTURES- MODEL NUMBERS, QUANTITY AND DISTANCE
BETWEEN LIGHTING FIXTURE PER FLOOR PLANS.
2. PRIOR TO ROUGH-IN E.C. SHALL VERIFY FIXTURE
QUANTITY, MODELS, STYLE, TRIM, LENS, ETC. WITH OWNER
FOR ALL FIXTURES.
3. PROVIDE LIGHTING FIXTURES COMPLETE WITH, BUT NOT
NECESSARILY LIMITED TO, HOUSINGS, LAMPS, LAMP
HOLDERS, REFLECTORS, BALLASTS, STARTERS AND
WIRING.
4. INSTALL LIGHTING FIXTURES AT LOCATIONS AND HEIGHTS
AS INDICATED, IN ACCORDANCE WITH FIXTURE
MANUFACTURER'S WRITTEN INSTRUCTIONS, APPLICABLE
REQUIREMENTS OF NEC, NECA'S "STANDARD OF
INSTALLATION", NEMA STANDARDS, AND WITH RECOGNIZED
INDUSTRY PRACTICES TO ENSURE THAT LIGHTING
FIXTURES FULFILL REQUIREMENTS.
5. COORDINATE WITH OTHER ELECTRICAL WORK AS
APPROPRIATE TO PROPERLY INTERFACE INSTALLATION OF
INTERIOR LIGHTING FIXTURES WITH OTHER WORK.
6. E.C. TO FASTEN FIXTURES SECURELY DIRECTLY TO
BUILDING STRUCTURAL SYSTEM. LIGHT TROFFERS SHALL
BE SUPPORTED AT EACH CORNER OF FIXTURE BY WIRES
OF SAME GAUGE AS HANGER WIRE FOR CEILING GRID.
ATTACH EARTHQUAKE CLIPS TO GRID AS RECOMMENDED
BY LIGHT MANUFACTURER. USE SCREWS IF REQUIRED BY
MANUFACTURER. ATTACH THE WIRE TO THE STRUCTURE
ABOVE. LIGHTS SHALL NOT BE SUPPORTED IN ANYWAY BY
LAY-IN CEILING.
7. FIXTURE LOCATIONS SHALL BE AT APPROXIMATE
LOCATIONS AS SHOWN ON THE DRAWINGS FREE FROM ALL
OBSTRUCTIONS. CLEAN ALL LIGHTING EQUIPMENT AFTER
LIGHTING INSTALLATION AND GENERAL CONSTRUCTION IS
COMPLETE. REPAIR ANY FIXTURES DAMAGED DURING
CONSTRUCTIONS.
8. PROVIDE NECESSARY MOUNTING FRAMES, SUPPORTS AND
RELATED ITEMS REQUIRED TO PROPERLY INSTALL
FIXTURES. SUPPORT FIXTURES INDEPENDENTLY OF PIPING
AND DUCTWORK. MAKE MODIFICATIONS TO THE
STRUCTURE AS REQUIRED TO INSTALL FIXTURES. ANY
MODIFICATIONS TO THE STRUCTURE SHALL NOT IMPAIR
THE STRUCTURAL INTEGRITY OF THE BUILDING.
LOW VOLTAGE
1. ALL LOW VOLTAGE CABLE WHERE CONCEALED IN
CONSTRUCTION SHALL BE RUN IN MINIMUM 3/4" CONDUIT.
LOW VOLTAGE CABLE INSTALLED IN EXPOSED OPEN AREAS
SHALL BE RUN FREE RUN. CONTRACTOR SHALL INSTALL
3/4" CONDUIT (MINIMUM) FROM EACH LOW VOLTAGE
ROUGH-IN LOCATION TO ACCESSIBLE CEILING SPACE, LOW
VOLTAGE WIRE TRAY OR HANGERS AND THEN TO MDF,
HEAD-IN, PBX PUNCH DOWN, CONTROLLER ETC.
2. E.C. SHALL COORDINATE WITH LOCAL PHONE AND CABLE
PROVIDER AS CHOSEN BY OWNER AND PROVIDE
RACEWAYS FOR BRINGING IN SERVICES AS REQUIRED.
3. ALL LOW VOLTAGE CABLE SHALL BE PLENUM RATED IN
PLENUMS.
4. ALL DATA CABLE SHALL BE CAT 6 UNLESS OTHER WISE
NOTED. TERMINATE, LABEL AND TEST ALL WIRING.
5. ALL TV CABLE SHALL BE HIGH DEFINITION COAX RG6 OR AS
REQUIRED BY PROVIDER, VERIFY PRIOR TO ROUGH IN.
FIRE STOPPING.
1. FIRE STOPPING SYSTEMS SHALL BE IN FULL COMPLIANCE
WITH SECTIONS 714 OF THE IBC AND NFPA 221.
2. CONTRACTOR SHALL MAKE REFERENCE TO
ARCHITECTURAL PLANS AND PROVIDE ALL REQUIRED FIRE
STOPPING.
3. CONTRACTOR SHALL PROVIDE AHJ WITH FULL SUBMITTAL
INDICATING METHODS OF CONSTRUCTION AND UL LISTINGS
FOR EACH PENETRATION SYSTEM USED.
4. PENETRATIONS OF FIRE-RESISTANCE-RATED WALLS OR
FLOOR CEILING ASSEMBLIES BY ELECTRICAL DEVICES,
RACEWAYS OR PANELS, ETC. SHALL COMPLY WITH
SECTIONS 713.2 THROUGH 713.3.3 OF THE IBC.
5. ACCESS DOORS REQUIRED IN CEILINGS OF
FIRE-RESISTANCE-RATED FLOOR/CEILING AND
ROOF/CEILING ASSEMBLIES SHALL BE TESTED IN
ACCORDANCE WITH ASTM E 119 OR UL 263 AS HORIZONTAL
ASSEMBLIES AND LABELED BY AN APPROVED AGENCY FOR
SUCH PURPOSE.
CLOSE OUT
1. PROVIDE MANUFACTURERS OPERATION AND
MAINTENANCE MANUALS AND PROVIDE AS BUILT
DRAWINGS. PROVIDE (1) TRAINING SESSION TO OWNER
SELECTED PERSONNEL AS REQUESTED AND PROVIDE
WARRANTY INFORMATION FOR ALL MANUFACTURERS
WARRANTED EQUIPMENT
AMPS
MECHANICAL CONTRACTOR
ELECTRICAL ABBREVIATIONS
MANUFACTURER
MOUNTING HEIGHT
MFR
MH
MINIMUM
MOTOR OPERATED DAMPER
MLO
MIN
MOD
MOCP
MOUNTED
NOT IN CONTRACT
PLUMBING CONTRACTOR
ON CENTER
NOT TO SCALE
MTD
NIC
PC
NTS
OC
COMPANYCO
RUNNING LOAD AMPSRLA
ELECTRIC CONTRACTOR
DOWN
DRAWING(S)
ELECTRICAL DISTRIBUTION CENTER
EQUIPMENT
EC
DN
DWG(S)
EQUIP
EDC
EWC
ETR
FULL LOAD AMPS
MAXIMUM
FLA
MAX
MAIN BREAKERMB
MC
CONTRACTORCONTR
EXISTING TO REMAIN
ELECTRIC WATER COOLER
MIMIMUM CIRCUIT AMPSMCA
MAXIMUM OVER CURRENT PROTECTION
MAIN LUG ONLY
EMERGENCYEM
POUNDS PER SQUARE INCHPSI
REVOLUTIONS PER MINUTERPM
HORSE POWERHP
GENERAL CONTRACTORGC
ABOVE FINISHED FLOORAFF
EX EXISTING
FLOW SWITCHFS
A
VOLTSV
UNLESS OTHERWISE NOTEDUON
LIGHTING
PANELBOARD SCHEDULE
ABBREVIATIONS
POWER NON-SEASONALPN
MOTOR SUMMER
MOTOR NON-SEASONAL
MOTOR NON-SEASONAL INTERMITTENT
MOTOR WINTER
MS
MN
MNI
MW
POWER WINTERPW
KITCHEN KT
RECEPTACLER
L
ELECTRICAL SYMBOLS
SPECIAL EQUIPMENT COORDINATE W/SUPPLIER
JUNCTION BOX
DISCONNECT
OUTLET - 4 WAY
MOTOR
OUTLET - GROUND FAULT INTERRUPT
OUTLET - DUPLEX
RECESSED DOWN LIGHT
LIGHT FIXTURE - ON NIGHT LIGHT CIRCUIT
LAYIN TROFFER FIXTURE
SUSPENDED LAYIN
EXIT SIGNAGE
SURFACE MOUNTED STRIP LIGHT
SUSPENDED STRIP LIGHT
LOW VOLTAGE TWO LINE
LOW VOLTAGE ONE LINE
ANALOG PHONE LINE
WIRELESS ACCESS POINT
OUTLET - 220V
EXIT SIGNAGE WITH EMERGENCY HEADS
LIGHT FIXTURE - WALL SCONCE
LIGHT FIXTURE - PENDANT
SURFACE MOUNTED LAYIN
J
FLRFLOOR OUTLET WITH POWER, DATA AND PHONE
D
3
SWITCH
SWITCH WITH DIMMER
SWITCH - 3 WAY
OSSWITCH WITH OCCUPANCY SENSOR
CEILING MOUNTED OCCUPANCY SENSOR
4SWITCH - 4 WAY
OUTLET - GROUND FAULT INTERRUPT WEATHERPROOF WP
LOW VOLTAGE # LINES #
PUSH BUTTON
BUZZER B
TIME CLOCK TC
PHOTO CELL P
POWER POLE
PANEL DESIGATION
X: XX,XX,XX
CIRCUIT BREAKER NUMBERS
WAP
EMERGENCY LIGHTING UNIT
EMERGENCY EXIT EGRESS LIGHT
LIGHT FIXTURE - TRACK
LIGHT FIXTURE - UNDER COUNTER
LIGHT FIXTURE - RECESSED DOWN LIGHT
LIGHT FIXTURE - VANITY LIGHT
OUTLET - DUPLEX WITH USB
J
PP
OS
HS
WP
ELECTRICAL
ABBREVIATIONS,
SYMBOLS, &
SPECIFICATIONS
1. A MANUAL FIRE ALARM SYSTEM THAT ACTIVATES THE
OCCUPANT NOTIFICATION SYSTEM SHALL BE DESIGNED
AND INSTALLED IN ACCORDANCE WITH SECTION 907 OF
THE IBC, NFPA 72 AND THE LOCAL FIRE DEPARTMENT.
2. THE FINAL DESIGN FOR THE FIRE ALARM SYSTEM SHALL
BE BY A LICENSED FIRE PROTECTION CONTRACTOR
WITH A MINIMUM OF 5 YEARS EXPERIENCE. THE SYSTEM
SHALL BE FULLY ADDRESSABLE. FIRE ALARM DEVICES
ON THE PLANS ARE FOR INTENT ONLY. FINAL DESIGN
SHALL BE BY MINIMUM NICET III LICENSED DESIGNER
AND SHALL BE SUBMITTED AND APPROVED BY ALL
AUTHORITIES HAVING JURISDICTION. REGARDLESS OF
WHAT IS INDICATED ON THESE INTENT PLANS
CONTRACTOR SHALL PROVIDE ALL REQUIRED DEVICES
NEEDED FOR THE APPROVED SYSTEM AT NO
ADDITIONAL COST TO THE OWNER.
3. FIRE ALARM CONTRACTOR SHALL SUBMIT THEIR PLANS
FOR REVIEW AND APPROVAL BY AUTHORITY(S) HAVING
JURISDICTION AND SHALL BE RESPONSIBLE FOR
OBTAINING ALL REQUIRED APPROVALS AND PERMITS
AND FOR PASSING ALL REQUIRED INSPECTIONS.
4. GENERAL SPECIFICATIONS INCLUDE BUT ARE NOT
LIMITED TO THE FOLLOWING:
a. SYSTEM SHALL BE EQUIPPED WITH AUTOMATIC
EMERGENCY POWER WITH A MINIMUM 24 HOUR
SUPPLY.
b. ACTIVATION OF THE GENERAL ALARM MUST SOUND
AN ALARM AND/OR VOICE EVACUATION THROUGH
OUT THE BUILDING IN ALL OCCUPIED AREAS.
c. CABLING AND CONNECTION SHALL HAVE A MINIMUM
60 MINUTE FIRE RESISTANCE RATING.
d. VISUAL STROBE DEVICES ARE REQUIRED AT ALL
HORNS AND IN ALL PUBLIC AREAS.
e. DETECTORS SHALL INCLUDE SMOKE DETECTORS
(AREA AND DUCT) AND HEAT DETECTORS AS
REQUIRED.
f. ALL ELECTRONIC DOOR LOCKS AND HOLD OPEN
DEVICES SHALL BE INTERLOCKED TO RELEASE
DOORS IN FIRE ALARM CONDITION.
g. POWER TO FIRE ALARM CONTROL PANEL SHALL BE
PROVIDED WITH CIRCUIT BREAKER LOCK PER NFPA
72-13, SECTION 10.6.5.4.
FIRE ALARM SPECIFICATIONS
220
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
07/14/21
07/14/21
OFFICE
101
TELECOM
103BREAKROOM
102 WC
105
JANITOR
104
A:10
EF-5
150
EF-4
75
F-1
2.5 TON
EF-5
A:14 F-1
A:29
L1
L1 L1
L1
L1L1
L1
L1
E2
E2
L2
L1 L1 L1
L1
EF-4
A:12
L1
EF-6
A:12
FACP
S
L2
X2
X2
HA:20 HA:20 HA:20 HA:20 HA:20 HA:20
HA:20
HA:20
HA:20
HA:20
HA:20
HA:20
HA:20
HA:20 HA:20
HS
F
FAAPS
A:8
A:8
A:16
TV
A:16
A:18
TV A:18A:18
A:18 A:18 A:18
A:16
A:16
S
A:12
WH
A:37,39
#10
+42" +42" A:30
A:20
A:20
A:20
A:20
+42"
A:24A:22 +66"
A:26
E003
ELECTRICAL
SCHEDULES &
ENLARGED
OFFICE
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
1 SCALE: 1/4" = 1'-0"
ENLARGED OFFICE ELECTRICAL PLAN N
KEY NOTES:
PROVIDE AND INSTALL (2) 1-1/2" CONDUITS FROM
EACH PODIUM, ONE FOR POWER AND ONE FOR
LOW VOLTAGE. COORDINATE FINAL LOCATIONS
WITH G.C.
PROVIDE PATHWAYS FOR (2) HDMI CABLES IN
WALLS AND OVER CEILINGS TO (2) MONITORS AS
SHOWN FROM DVR IN BREAK ROOM CABINET.
FIELD COORDINATE EXACT DEVICE ROUGH-IN
LOCATION WITH ELECTRIC WATER COOLER
INSTALLER.
INSTALL POWER FOR DVR LOCATED IN UPPER
CABINET. COORDINATE WITH MILLWORK
CONTRACTOR.
CONCEAL TV OUTLETS AND RECEPTACLES BEHIND
TV LOCATIONS. FIELD COORDINATE FINAL
ROUGH-IN LOCATIONS.
PROVIDE OUTLETS IN STRUCTURE ABOVE TOP OF
WINDOW MULLIONS.
INSTALL RECEPTACLES COUNTER MOUNTED
MICROWAVE, UNDER COUNTER REFRIGERATOR
AND COUNTER TOP CONVENIENCE. COORDINATE
WITH MILLWORK.
PROVIDE AND INSTALL ELECTRICAL HAND DRYER
SIMILAR TO XLERATOR #XL-BW-220. COORDINATE
DRYER FINISH WITH OWNER. PROVIDE DEDICATED
120 VOLT BRANCH CIRCUIT FOR DRYER. FIELD
COORDINATE DRYER ROUGH-IN LOCATION.
PROVIDE DEDICATED CIRCUIT FOR ELECTRIC
FURNACE AND CONNECT.
PROVIDE DEDICATED CIRCUIT WITH DISCONNECT
FOR ELECTRIC WATER HEATER AND CONNECT.
CONTROL EXHAUST FAN WITH LIGHT SWITCH IN
THIS ROOM.
REMOTE KEYPAD SYSTEM. PROVIDE RECEPTACLE
FOR MAG LOCK TRANSFORMER AND ROUGH IN FOR
KEY PAD. COORDINATE LOCATION OF SYSTEM
CONTROLLER WITH OWNER AND PROVIDE POWER
AS REQUIRED. KEY PAD LIKE PTI APEX WITH
SOFTWARE INTERFACE FALCON 2000 SOFTWARE
FOR OMNI. PURCHASE THROUGH PTI ACCESS
CONTROLS. FIELD COORDINATE EXACT ROUGH-IN
LOCATION FOR DEVICE LOCATIONS.
PROVIDE POWER CIRCUIT FOR FEATURE WALL
SIGN. COORDINATE WITH G.C.
INSTALL 4'X4' TREATED CDX PLYWOOD BACK
BOARD WITH DEDICATED QUAD OUTLET. INSTALL
(2) 3" CONDUITS FOR INCOMING LOW VOLTAGE
SERVICES FROM EXTERIOR UTIILITY TIE IN POINT
TO TELECOM ROOM BACKBOARD. REFER TO CIVIL
PLANS FOR ADDITIONAL INFORMATION.
1
2
3
4
5
6
7
8
9
10
11
12
13
GENERAL NOTES:
1. REFERENCE SHEET E001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
2. REFERENCE SHEET E002 FOR ELECTRICAL
RISER DIAGRAM AND SCHEDULES.
3. E.C. SHALL PROVIDE ALL RACEWAYS AND
CONDUCTORS FOR HVAC INTERLOCKS AND
THERMOSTATS. PRIOR TO ROUGH-IN,
COORDINATE EXACT REQUIREMENTS WITH
M.C.
4. ALL EXIT SIGNS, EMERGENCY LIGHTING UNITS,
AND NIGHT LIGHTS SHALL HAVE UNSWITCHED
CONDUCTOR. CONNECT LIGHT FIXTURES TO
NEAREST UNSWITCHED LIGHTING BRANCH
CIRCUIT.
5. FIRE ALARM DEVICES SHOWN ARE
DIAGRAMMATIC AND MAY NOT INDICATE TOTAL
REQUIREMENTS. E.C. TO PROVIDE FINAL
DESIGN AND RECEIVE APPROVALS FROM AHJ.
SEE SPECIFICATIONS ON SHEET E001.
6. ALL EXTERIOR LIGHTING SHALL BE
CONTROLLED BY PHOTOCELL WITH
TIMECLOCK OVERRIDE AS REQUIRED PER
ASHRAE 90.1.
14
14
1
1
2
2
4
5
5
7
8 9
10
11
07/14/21
T
UTILITY
METERS00°05'46"E(M) S00°45'10"W(D) 411.64 'N00°05'46"W(M) N00°45'10"E(D) 398.63'S89°17'51"W(M) N89°51'24"W(D) 226.23' S89°17'51"W(M) N89°51'24"W(D) 206.01'
N89°25'05"E(M) S89°43'58"E(D) 206.02'
N00°50'56"W(M)
N00°00'00"W(D) S00°50'56"E(M)S00°00 '00"E (D)181.33'(M) 182.73'(D)N89°48'49"E(M) S89°20'15"E(D) 190.00
' N89°25'05"E(M) S89°43'58"E(D) 241.02'
UP
A
1
A.1 B B.1 C C.1 D
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
OFFICE101
ELEC.
106
STAIR108
SPRINKLER
107
ELEV.109
TELECOM103
STORAGE UNITS 100
CORRIDOR
110
BREAKROOM
102 WC
105JANITOR104
A A.1 B B.1 C C.1 D
32
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
LOADINGBAY112
STAIR
111
STORAGEUNITS100
J
A:38
UTILITY POLE
(EXISTING)
WP
UTILITY POLE
(EXISTING)
UTILITY
TRANSFORMER
(POLE
MOUNTED)
J GATE KEYPAD
WM2
HA:26
+15'
WM2
HA:26
+15'
WM1
HA:26
+12.5'
WM1
HA:26
+12.5'
WM1
HA:26
+12.5'
WM3
HA:26
+15'
WM3
HA:26
+15'
WM3
HA:26
+15'
SERVICE
SECONDARY
(SEE RISER
DIAGRAM)
E050
ELECTRICAL SITE
PLAN
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
1 SCALE: 1" = 30'-0"
ELECTRICAL SITE PLAN
N
KEY NOTES:
PROVIDE ALL CONNECTIONS TO GATE OPERATOR
AND BOLLARD MOUNTED KEYPAD. PROVIDE
POWER AND DATA CONDUITS TO GATE OPERATOR
AS REQUIRED. REFERENCE SHEET E002 FOR
ADDITIONAL INFORMATION. FIELD COORDINATE
ALL WORK WITH GATE INSTALLER FOR A COMPLETE
INSTALLATION.
FIELD COORDINATE WITH UTILITY COMPANY ALL
WORK REQUIRED TO DECOMMISSION AND REMOVE
EXISTING ELECTRICAL SERVICE AND REPLACE
WITH NEW. ESTABLISH NEW UTILITY
TRANSFORMER AS NECESSARY AND DIRECTED BY
UTILITY COMPANY. FIELD VERIFY ALL COUNTS AND
CONDITIONS PRIOR TO BID.
FIELD COORDINATE EXACT LOCATION OF UTILITY
METER WITH UTILITY COMPANY.
1
GENERAL NOTES:
1. REFERENCE SHEET E001 FOR ELECTRICAL
LEGENDS, ABBREVIATIONS, SPECIFICATIONS AND
NOTES.
2. REFERENCE SHEET E002 FOR ELECTRICAL DETAILS
& RISER DIAGRAM.
3. REFERENCE SHEET E003 FOR ELECTRICAL
SCHEDULES & ENLARGED OFFICE.
4. ALL EXIT SIGNS, EMERGENCY LIGHTING UNITS, AND
NIGHT LIGHTS SHALL HAVE UNSWITCHED
CONDUCTOR. TIE FIXTURE IN TO THE NEAREST
UNSWITCH BRANCH LIGHTING CIRCUITRY.
5. ALL EXTERIOR LIGHTING SHALL BE CONTROLLED BY
PHOTOCELL WITH TIMECLOCK OVERRIDE AS
REQUIRED PER ASHRAE 90.1.
1
2
3
3
2
07/14/21
07/14/21
07/14/21
DN
A
1
A.1 B B.1 C C.1 D
2
3
4
5
6
7
8
9
10
11
12
13
14
15
ELEV.
302
STAIR
301
STORAGE
UNITS
300
15 102 SF10 x 10102 SF 10 x 1099 SF10 x 10150 SF7.5 x 12.599 SF10 x 1099 SF10 x 1099 SF10 x 10153 SF7.5 x 12.549 SF10 x 5102 SF10 x 10102 SF10 x 10102 SF10 x 10103 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF 10 x 1099 SF10 x 1099 SF10 x 10148 SF10 x 13.5139 SF10 x 13.5134 SF10 x 13.5141 SF10 x 13.5147 SF10 x 15145 SF10 x 15149 SF10 x 1549 SF10 x 549 SF 10 x 549 SF10 x 598 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1049 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 5149 SF10 x 1599 SF10 x 1020 SF5 x 320 SF5 x 3102 SF10 x 10102 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10102 SF10 x 1099 SF10 x 1049 SF10 x 549 SF10 x 549 SF10 x 5L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4L4
L4L4L4
L4L4 L4
L4
E1
E1
E1
E1
E1
E1
E1
E1
E1
E1
E1
X2
X1
X1
X1X1
X1 X1
X1
X1
X1
OS
OS
OS OS
OS OS
OS
OS
OS
OS
L4
L4
H
A:7
A:7 A:9
HS
F
HS
HS HS
HS
A:25
A:25
A:25
S
A:25
J
HA:17
WP
BUILDING SIGN
OS
L6
A:36
OS
L6
A:36
L4 L4
L4 L4
OS L6
A:36
OSL6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OSL6
A:36
OS L6
A:36
15
A A.1 B B.1 C C.1 D
32
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
STAIR
303
STORAGE
UNITS
300 99 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 1599 SF10 x 1099 SF10 x 1099 SF10 x 10149 SF10 x 15150 SF10 x 1591 SF10 x 10149 SF10 x 15154 SF10 x 15149 SF10 x 15149 SF10 x 1549 SF10 x 549 SF10 x 549 SF10 x 5149 SF10 x 15L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4L4 L4
L3
E1
E1
E1
E1
E1
E1
E1
E1
X2 X1 X1
L3
OS OS
OS OS
OS OS
OS
HS
HS
HS
F
A:25
A:25
A:25
HS
HS
HS
HS
F
HS
OS L6
A:36
OS
L6
A:36
L4L4
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS L6
A:36
OS
L6
A:36
OS L6
A:36
OS
L6
A:36
OS L6
A:36
OS
L6
A:36
OS L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS L6
A:36
OS L6
A:36
E300
THIRD FLOOR
ELECTRICAL
PLAN
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
1 SCALE: 1/8" = 1'-0"
THIRD FLOOR ELECTRICAL AREA A 2 SCALE: 1/8" = 1'-0"
THIRD FLOOR ELECTRICAL PLAN AREA B N
MATCH LINE A-A MATCH LINE A-A
MATCH LINE A-A MATCH LINE A-A
KEY NOTES:
INSTALL GFI DUPLEX RECEPTACLE AT TOP OF
STORAGE UNIT FACING CEILING. MAXIMUM
SPACING NOT TO EXCEED 150' BETWEEN
RECEPTACLES. TYPICAL.
PROVIDE CONNECTION TO BUILDING SIGNAGE.
FIELD COORDINATE EXACT LOCATION AND
ELECTRICAL REQUIREMENTS WITH SIGNAGE
INSTALLER. SIGNAGE SHALL BE CONTROLLED BY
TIME CLOCK.
ELEVATOR PIT LIGHTS AND RECEPTACLES SHALL
HAVE SEPARATE DEDICATED BRANCH CIRCUITRY.
FIELD COORDINATE EXACT DEVICE LOCATION WITH
ELEVATOR INSTALLER TO INSURE THAT ROUGH-IN
LOCATIONS DO NOT INTERFERE WITH OPERATION
OF ELEVATOR.
PROVIDE OCCUPANCY SENSORS IN CEILINGS TO
CONTROL HALLWAY, OFFICE AND UNIT LIGHTING
WITH 20 MINUTE TIME DELAY. PROVIDE BZ-50
UNIVERSAL POWER PACKS WITH WATT STOPPER /
LEGRAND DUAL TECHNOLOGY FOR LIGHTS ABOVE
STORAGE ROOMS AND INFRARED FOR HALLWAY
LIGHTING. QUANTITIES AND LOCATIONS ON
DRAWINGS ARE DIAGRAMMATIC. E.C. SHALL
PROVIDE VENDOR SHOP DRAWINGS FOR
APPROVAL FOR ALL LIGHTING CONTROLS AND
SHALL BE RESPONSIBLE TO ADD OR ADJUST IN
FIELD TO ENSURE LIGHTING FUNCTIONS PROPERLY
AND HALLWAYS AND ROOMS HAVE NO DEAD
SPOTS. TYPICAL.
1
2
3
GENERAL NOTES:
1. REFERENCE SHEET E001 FOR ELECTRICAL
LEGENDS, ABBREVIATIONS, SPECIFICATIONS AND
NOTES.
2. REFERENCE SHEET E002 FOR ELECTRICAL DETAILS
& RISER DIAGRAM.
3. REFERENCE SHEET E003 FOR ELECTRICAL
SCHEDULES & ENLARGED OFFICE.
4. MOUNT TYPE E1 LIGHT FIXTURE AT +9'-0" A.F.F.
5. ALL EXIT SIGNS, EMERGENCY LIGHTING UNITS, AND
NIGHT LIGHTS SHALL HAVE UNSWITCHED
CONDUCTOR. TIE FIXTURE IN TO THE NEAREST
UNSWITCH BRANCH LIGHTING CIRCUITRY.
6. TYPE E2 LIGHTS SHALL BE EMERGENCY ON ONLY.
7. E.C. SHALL PROVIDE ALL RACEWAYS AND
CONDUCTORS FOR HVAC INTERLOCKS AND
THERMOSTATS. PRIOR TO ROUGH-IN, COORDINATE
EXACT REQUIREMENTS WITH M.C.
8. CONNECT NEW LIGHT FIXTURES TO NEAREST
AVAILABLE 277V 20A-1P BRANCH CIRCUIT BREAKER.
DO NOT EXCEED NEC ALLOWANCES FOR BRANCH
CIRCUIT LOADING. PROVIDE LIGHTING CONTROL
WHERE INDICATED.
9. ALL OCCUPANCY CONTROLS ARE PROVIDED AND
INSTALLED BY E.C. DRAWING LOCATIONS ARE
DIAGRAMMATIC, E.C. TO WORK WITH OCCUPANCY
CONTROL VENDOR AND PROVIDE AND INSTALL AS
NEEDED TO CONTROL LIGHTS WITH NO DEAD SPOTS
IN HALLWAYS.
2
1
4
5
43
1
5
5
07/14/21
A
1
A.1 B B.1 C C.1 D
2
3
4
5
6
7
8
9
10
11
12
13
14
1515
ACCU-1
A:31,33,35 (#10)
RTU-1
HA:8,10,12
3#3 AL,#6G AL, 1"C
SSD
WP
A:27
WP
A:27
WP
13
14
15
A A.1 B B.1 C C.1 D
32
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
RTU-2
HA:14,16,18
3#3 AL,#6G AL, 1"C
SSD
WP
A:27
WP
E400
ELECTRICAL
ROOF PLAN
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
1 SCALE: 1/8" = 1'-0"
ELECTRICAL ROOF PLAN AREA A 2 SCALE: 1/8" = 1'-0"
ELECTRICAL ROOF PLAN AREA B
1. REFERENCE SHEET E001 FOR ELECTRICAL
LEGENDS, ABBREVIATIONS, SPECIFICATIONS
AND NOTES.
2. REFERENCE SHEET E002 FOR ELECTRICAL
DETAILS & RISER DIAGRAM.
3. REFERENCE SHEET E003 FOR ELECTRICAL
SCHEDULES & ENLARGED OFFICE.
GENERAL NOTES:
MATCH LINE D MATCH LINE D
MATCH LINE D MATCH LINE D
N
07/14/21