HomeMy WebLinkAboutE003 - 100_BID AND PERMIT (08-27-20)OFFICE
101
TELECOM
103BREAKROOM
102 WC
105
JANITOR
104
A:10
EF-5
150
EF-4
75
F-1
2.5 TON
EF-5
A:14 F-1
A:29
L1
L1 L1
L1
L1L1
L1
L1
E2
E2
L2
L1 L1 L1
L1
EF-4
A:12
L1
EF-6
A:12
FACP
S
L2
X2
X2
HA:20 HA:20 HA:20 HA:20 HA:20 HA:20
HA:20
HA:20
HA:20
HA:20
HA:20
HA:20
HA:20
HA:20 HA:20
HS
F
FAAPS
A:8
A:8
A:16
TV
A:16
A:18
TV A:18A:18
A:18 A:18 A:18
A:16
A:16
S
A:12
WH
A:37,39
#10
+42" +42" A:30
A:20
A:20
A:20
A:20
+42"
A:24A:22 +66"
A:26
E003
ELECTRICAL
SCHEDULES &
ENLARGED
OFFICE
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
1 SCALE: 1/4" = 1'-0"
ENLARGED OFFICE ELECTRICAL PLAN N
KEY NOTES:
PROVIDE AND INSTALL (2) 1-1/2" CONDUITS FROM
EACH PODIUM, ONE FOR POWER AND ONE FOR
LOW VOLTAGE. COORDINATE FINAL LOCATIONS
WITH G.C.
PROVIDE PATHWAYS FOR (2) HDMI CABLES IN
WALLS AND OVER CEILINGS TO (2) MONITORS AS
SHOWN FROM DVR IN BREAK ROOM CABINET.
FIELD COORDINATE EXACT DEVICE ROUGH-IN
LOCATION WITH ELECTRIC WATER COOLER
INSTALLER.
INSTALL POWER FOR DVR LOCATED IN UPPER
CABINET. COORDINATE WITH MILLWORK
CONTRACTOR.
CONCEAL TV OUTLETS AND RECEPTACLES BEHIND
TV LOCATIONS. FIELD COORDINATE FINAL
ROUGH-IN LOCATIONS.
PROVIDE OUTLETS IN STRUCTURE ABOVE TOP OF
WINDOW MULLIONS.
INSTALL RECEPTACLES COUNTER MOUNTED
MICROWAVE, UNDER COUNTER REFRIGERATOR
AND COUNTER TOP CONVENIENCE. COORDINATE
WITH MILLWORK.
PROVIDE AND INSTALL ELECTRICAL HAND DRYER
SIMILAR TO XLERATOR #XL-BW-220. COORDINATE
DRYER FINISH WITH OWNER. PROVIDE DEDICATED
120 VOLT BRANCH CIRCUIT FOR DRYER. FIELD
COORDINATE DRYER ROUGH-IN LOCATION.
PROVIDE DEDICATED CIRCUIT FOR ELECTRIC
FURNACE AND CONNECT.
PROVIDE DEDICATED CIRCUIT WITH DISCONNECT
FOR ELECTRIC WATER HEATER AND CONNECT.
CONTROL EXHAUST FAN WITH LIGHT SWITCH IN
THIS ROOM.
REMOTE KEYPAD SYSTEM. PROVIDE RECEPTACLE
FOR MAG LOCK TRANSFORMER AND ROUGH IN FOR
KEY PAD. COORDINATE LOCATION OF SYSTEM
CONTROLLER WITH OWNER AND PROVIDE POWER
AS REQUIRED. KEY PAD LIKE PTI APEX WITH
SOFTWARE INTERFACE FALCON 2000 SOFTWARE
FOR OMNI. PURCHASE THROUGH PTI ACCESS
CONTROLS. FIELD COORDINATE EXACT ROUGH-IN
LOCATION FOR DEVICE LOCATIONS.
PROVIDE POWER CIRCUIT FOR FEATURE WALL
SIGN. COORDINATE WITH G.C.
INSTALL 4'X4' TREATED CDX PLYWOOD BACK
BOARD WITH DEDICATED QUAD OUTLET. INSTALL
(2) 3" CONDUITS FOR INCOMING LOW VOLTAGE
SERVICES FROM EXTERIOR UTIILITY TIE IN POINT
TO TELECOM ROOM BACKBOARD. REFER TO CIVIL
PLANS FOR ADDITIONAL INFORMATION.
1
2
3
4
5
6
7
8
9
10
11
12
13
GENERAL NOTES:
1. REFERENCE SHEET E001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
2. REFERENCE SHEET E002 FOR ELECTRICAL
RISER DIAGRAM AND SCHEDULES.
3. E.C. SHALL PROVIDE ALL RACEWAYS AND
CONDUCTORS FOR HVAC INTERLOCKS AND
THERMOSTATS. PRIOR TO ROUGH-IN,
COORDINATE EXACT REQUIREMENTS WITH
M.C.
4. ALL EXIT SIGNS, EMERGENCY LIGHTING UNITS,
AND NIGHT LIGHTS SHALL HAVE UNSWITCHED
CONDUCTOR. CONNECT LIGHT FIXTURES TO
NEAREST UNSWITCHED LIGHTING BRANCH
CIRCUIT.
5. FIRE ALARM DEVICES SHOWN ARE
DIAGRAMMATIC AND MAY NOT INDICATE TOTAL
REQUIREMENTS. E.C. TO PROVIDE FINAL
DESIGN AND RECEIVE APPROVALS FROM AHJ.
SEE SPECIFICATIONS ON SHEET E001.
6. ALL EXTERIOR LIGHTING SHALL BE
CONTROLLED BY PHOTOCELL WITH
TIMECLOCK OVERRIDE AS REQUIRED PER
ASHRAE 90.1.
14
14
1
1
2
2
4
5
5
7
8 9
10
11
07/14/21