Loading...
HomeMy WebLinkAboutE050 - 100_BID AND PERMIT (08-27-20)T UTILITY METERS00°05'46"E(M) S00°45'10"W(D) 411.64 'N00°05'46"W(M) N00°45'10"E(D) 398.63'S89°17'51"W(M) N89°51'24"W(D) 226.23' S89°17'51"W(M) N89°51'24"W(D) 206.01' N89°25'05"E(M) S89°43'58"E(D) 206.02' N00°50'56"W(M) N00°00'00"W(D) S00°50'56"E(M)S00°00 '00"E (D)181.33'(M) 182.73'(D)N89°48'49"E(M) S89°20'15"E(D) 190.00 ' N89°25'05"E(M) S89°43'58"E(D) 241.02' UP A 1 A.1 B B.1 C C.1 D 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 OFFICE101 ELEC. 106 STAIR108 SPRINKLER 107 ELEV.109 TELECOM103 STORAGE UNITS 100 CORRIDOR 110 BREAKROOM 102 WC 105JANITOR104 A A.1 B B.1 C C.1 D 32 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 LOADINGBAY112 STAIR 111 STORAGEUNITS100 J A:38 UTILITY POLE (EXISTING) WP UTILITY POLE (EXISTING) UTILITY TRANSFORMER (POLE MOUNTED) J GATE KEYPAD WM2 HA:26 +15' WM2 HA:26 +15' WM1 HA:26 +12.5' WM1 HA:26 +12.5' WM1 HA:26 +12.5' WM3 HA:26 +15' WM3 HA:26 +15' WM3 HA:26 +15' SERVICE SECONDARY (SEE RISER DIAGRAM) E050 ELECTRICAL SITE PLAN REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m CLIENT JP DRG 08/27/2020 200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage 900 Keystone Crossing, Ste. 230 Jim Adams Indianapolis, IN 46240 PH: 317-663-8648 CIVIL ENGINEER STRUCTURAL ENGINEER # DESCRIPTION DATE Weihe Engineers 10505 N. College Avenue Brad Schoeff - Sr. Project Manager Indianapolis, IN 46280 PH: 317-846-6611 Innovative Structural Solutions, P.A. 5279 Kyler Avenue, NE Albertville, IN 55301 PH: 763-425-9960 MEP ENGINEER Gooderum & Associates Engineering 874 Cheltenham Way David Gooderum, PE Avon, IN 46123 PH: 317-506-8151 1 SCALE: 1" = 30'-0" ELECTRICAL SITE PLAN N KEY NOTES: PROVIDE ALL CONNECTIONS TO GATE OPERATOR AND BOLLARD MOUNTED KEYPAD. PROVIDE POWER AND DATA CONDUITS TO GATE OPERATOR AS REQUIRED. REFERENCE SHEET E002 FOR ADDITIONAL INFORMATION. FIELD COORDINATE ALL WORK WITH GATE INSTALLER FOR A COMPLETE INSTALLATION. FIELD COORDINATE WITH UTILITY COMPANY ALL WORK REQUIRED TO DECOMMISSION AND REMOVE EXISTING ELECTRICAL SERVICE AND REPLACE WITH NEW. ESTABLISH NEW UTILITY TRANSFORMER AS NECESSARY AND DIRECTED BY UTILITY COMPANY. FIELD VERIFY ALL COUNTS AND CONDITIONS PRIOR TO BID. FIELD COORDINATE EXACT LOCATION OF UTILITY METER WITH UTILITY COMPANY. 1 GENERAL NOTES: 1. REFERENCE SHEET E001 FOR ELECTRICAL LEGENDS, ABBREVIATIONS, SPECIFICATIONS AND NOTES. 2. REFERENCE SHEET E002 FOR ELECTRICAL DETAILS & RISER DIAGRAM. 3. REFERENCE SHEET E003 FOR ELECTRICAL SCHEDULES & ENLARGED OFFICE. 4. ALL EXIT SIGNS, EMERGENCY LIGHTING UNITS, AND NIGHT LIGHTS SHALL HAVE UNSWITCHED CONDUCTOR. TIE FIXTURE IN TO THE NEAREST UNSWITCH BRANCH LIGHTING CIRCUITRY. 5. ALL EXTERIOR LIGHTING SHALL BE CONTROLLED BY PHOTOCELL WITH TIMECLOCK OVERRIDE AS REQUIRED PER ASHRAE 90.1. 1 2 3 3 2 07/14/21