HomeMy WebLinkAboutE300 - 100_BID AND PERMIT (08-27-20)DN
A
1
A.1 B B.1 C C.1 D
2
3
4
5
6
7
8
9
10
11
12
13
14
15
ELEV.
302
STAIR
301
STORAGE
UNITS
300
15 102 SF10 x 10102 SF 10 x 1099 SF10 x 10150 SF7.5 x 12.599 SF10 x 1099 SF10 x 1099 SF10 x 10153 SF7.5 x 12.549 SF10 x 5102 SF10 x 10102 SF10 x 10102 SF10 x 10103 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF 10 x 1099 SF10 x 1099 SF10 x 10148 SF10 x 13.5139 SF10 x 13.5134 SF10 x 13.5141 SF10 x 13.5147 SF10 x 15145 SF10 x 15149 SF10 x 1549 SF10 x 549 SF 10 x 549 SF10 x 598 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1049 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 5149 SF10 x 1599 SF10 x 1020 SF5 x 320 SF5 x 3102 SF10 x 10102 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10102 SF10 x 1099 SF10 x 1049 SF10 x 549 SF10 x 549 SF10 x 5L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4L4
L4L4L4
L4L4 L4
L4
E1
E1
E1
E1
E1
E1
E1
E1
E1
E1
E1
X2
X1
X1
X1X1
X1 X1
X1
X1
X1
OS
OS
OS OS
OS OS
OS
OS
OS
OS
L4
L4
H
A:7
A:7 A:9
HS
F
HS
HS HS
HS
A:25
A:25
A:25
S
A:25
J
HA:17
WP
BUILDING SIGN
OS
L6
A:36
OS
L6
A:36
L4 L4
L4 L4
OS L6
A:36
OSL6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OSL6
A:36
OS L6
A:36
15
A A.1 B B.1 C C.1 D
32
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
STAIR
303
STORAGE
UNITS
300 99 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 10149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 15149 SF10 x 1599 SF10 x 1099 SF10 x 1099 SF10 x 10149 SF10 x 15150 SF10 x 1591 SF10 x 10149 SF10 x 15154 SF10 x 15149 SF10 x 15149 SF10 x 1549 SF10 x 549 SF10 x 549 SF10 x 5149 SF10 x 15L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4
L4L4 L4
L3
E1
E1
E1
E1
E1
E1
E1
E1
X2 X1 X1
L3
OS OS
OS OS
OS OS
OS
HS
HS
HS
F
A:25
A:25
A:25
HS
HS
HS
HS
F
HS
OS L6
A:36
OS
L6
A:36
L4L4
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS L6
A:36
OS
L6
A:36
OS L6
A:36
OS
L6
A:36
OS L6
A:36
OS
L6
A:36
OS L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS
L6
A:36
OS L6
A:36
OS L6
A:36
E300
THIRD FLOOR
ELECTRICAL
PLAN
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
1 SCALE: 1/8" = 1'-0"
THIRD FLOOR ELECTRICAL AREA A 2 SCALE: 1/8" = 1'-0"
THIRD FLOOR ELECTRICAL PLAN AREA B N
MATCH LINE A-A MATCH LINE A-A
MATCH LINE A-A MATCH LINE A-A
KEY NOTES:
INSTALL GFI DUPLEX RECEPTACLE AT TOP OF
STORAGE UNIT FACING CEILING. MAXIMUM
SPACING NOT TO EXCEED 150' BETWEEN
RECEPTACLES. TYPICAL.
PROVIDE CONNECTION TO BUILDING SIGNAGE.
FIELD COORDINATE EXACT LOCATION AND
ELECTRICAL REQUIREMENTS WITH SIGNAGE
INSTALLER. SIGNAGE SHALL BE CONTROLLED BY
TIME CLOCK.
ELEVATOR PIT LIGHTS AND RECEPTACLES SHALL
HAVE SEPARATE DEDICATED BRANCH CIRCUITRY.
FIELD COORDINATE EXACT DEVICE LOCATION WITH
ELEVATOR INSTALLER TO INSURE THAT ROUGH-IN
LOCATIONS DO NOT INTERFERE WITH OPERATION
OF ELEVATOR.
PROVIDE OCCUPANCY SENSORS IN CEILINGS TO
CONTROL HALLWAY, OFFICE AND UNIT LIGHTING
WITH 20 MINUTE TIME DELAY. PROVIDE BZ-50
UNIVERSAL POWER PACKS WITH WATT STOPPER /
LEGRAND DUAL TECHNOLOGY FOR LIGHTS ABOVE
STORAGE ROOMS AND INFRARED FOR HALLWAY
LIGHTING. QUANTITIES AND LOCATIONS ON
DRAWINGS ARE DIAGRAMMATIC. E.C. SHALL
PROVIDE VENDOR SHOP DRAWINGS FOR
APPROVAL FOR ALL LIGHTING CONTROLS AND
SHALL BE RESPONSIBLE TO ADD OR ADJUST IN
FIELD TO ENSURE LIGHTING FUNCTIONS PROPERLY
AND HALLWAYS AND ROOMS HAVE NO DEAD
SPOTS. TYPICAL.
1
2
3
GENERAL NOTES:
1. REFERENCE SHEET E001 FOR ELECTRICAL
LEGENDS, ABBREVIATIONS, SPECIFICATIONS AND
NOTES.
2. REFERENCE SHEET E002 FOR ELECTRICAL DETAILS
& RISER DIAGRAM.
3. REFERENCE SHEET E003 FOR ELECTRICAL
SCHEDULES & ENLARGED OFFICE.
4. MOUNT TYPE E1 LIGHT FIXTURE AT +9'-0" A.F.F.
5. ALL EXIT SIGNS, EMERGENCY LIGHTING UNITS, AND
NIGHT LIGHTS SHALL HAVE UNSWITCHED
CONDUCTOR. TIE FIXTURE IN TO THE NEAREST
UNSWITCH BRANCH LIGHTING CIRCUITRY.
6. TYPE E2 LIGHTS SHALL BE EMERGENCY ON ONLY.
7. E.C. SHALL PROVIDE ALL RACEWAYS AND
CONDUCTORS FOR HVAC INTERLOCKS AND
THERMOSTATS. PRIOR TO ROUGH-IN, COORDINATE
EXACT REQUIREMENTS WITH M.C.
8. CONNECT NEW LIGHT FIXTURES TO NEAREST
AVAILABLE 277V 20A-1P BRANCH CIRCUIT BREAKER.
DO NOT EXCEED NEC ALLOWANCES FOR BRANCH
CIRCUIT LOADING. PROVIDE LIGHTING CONTROL
WHERE INDICATED.
9. ALL OCCUPANCY CONTROLS ARE PROVIDED AND
INSTALLED BY E.C. DRAWING LOCATIONS ARE
DIAGRAMMATIC, E.C. TO WORK WITH OCCUPANCY
CONTROL VENDOR AND PROVIDE AND INSTALL AS
NEEDED TO CONTROL LIGHTS WITH NO DEAD SPOTS
IN HALLWAYS.
2
1
4
5
43
1
5
5
07/14/21