HomeMy WebLinkAboutG002 - 100_BID AND PERMIT (08-27-20)APPLICABLE CODES CONSTRUCTION TYPE OCCUPANCY CLASSIFICATION ALLOWABLE AREA FIRE PROTECTIONS SYSTEMS SCOPE OF PROJECT INCIDENTAL USE SEPARATIONS EGRESS CORRIDORS PANIC HARDWARE Type II-B - Permitted based upon allowable area and height for S-2, B occupancy. Tabular Area: 60,663 SQ. FT. 3 Stories Actual Area Per Floor: First Floor: 18,309 sf Second Floor: 21,117 sf Third Floor: 21,117 sf Total: 60,663 sf Sprinklers Provide per NFPA 13 Portable fire extinguishers Required per Carmel Indiana Local Code Smoke detection Recommend interconnected smoke alarms in sleeping areas as a minimum Standpipes Are not required based upon the elevation of the 2nd floor level at less than 30 feet above grade (905.3.1) Fire Alarm System Not required based upon a calculated occupant load of over 100 above or below the level or discharge. (907.2.2) Smoke Detectors Are required for HVAC shutdown for systems delivering in excess of 2000 CFM, and for elevator recall. (3003.2, 606.1 IMC) Exit signs Required (Sec. 1011. 1) Exit illumination Required (Sec. 1 006) with emergency power New three story personal storage facility. Incidental use areas are required to be provided with smoke tight construction. Partitions shall extend from the floor to the underside of the floor, roof deck above, or tight ceiling. Doors shall be self-closing or automatic-closing upon detection of smoke. Air-transfer openings shall be provided with smoke dampers. Duct work does not need to be dampered. (509.4.2) The following areas are considered incidental use areas: (IBC Table 509). Boiler and fuel equipment rooms over 400,000 BTU's/hour input. Laundry rooms over 100 sq. ft. Egress corridors are not require to be fire rated based upon automatic sprinkler protection. (1018.1) Required in an S occupancy. (1008.1.10) Indiana General Administrative Rules 2014 Indiana Building Code (2012 International Building Code with Indiana Amendments) 2014 Indiana Fire Code (2012 International Fire Code with Indiana Amendments) 2012 Indiana Plumbing Code (2006 International Plumbing Code with Indiana Amendments) 2008 National Electrical Code (2008 NFPA 70) 2014 Indiana Mechanical Code (2012 International Mechanical Code with Indiana Amendments) 2010 Indiana Energy Code (ASHRAE 90.1 2007) Americans with Disabilities Act Accessible Guidelines (ADAAG) for Buildings and Facilities American National Standards Institute Accessible and Usable Buildings and Facilities Standard (CABO/ANSI A117.1-2009) B, S-2 Occupancy (304.1) EGRESS TRAVEL DISTANCE Table 1016. 1, IBC limits the maximum travel distance in a sprinklered B occupancy to 300 feet. NUMBER OF EXITS 2 means of egress are required from rooms or areas with an occupant load exceeding 50 or a common path of travel exceeding 100 feet. (1015.1) # Exits First Floor 2 Second Floor 2 Third Floor 2 OTHER SEPARATION Electrical "Rooms" Electrical vaults > 600 volts 3 hour rating [IEC, Sec. 110. 31 (A)] Transformers Dry type< 112-1/2 kVA Not required [IEC 450.21. (A)] > 112-1/2 kVA 1 hour [IEC 4502. 1 (B)]; See exception Vaults See section IEC 450.41 for exceptions Switch gear-unenclosed In a vault following IEC 450.41 Switch gear over 35,000 volts through 450.48; See IEC 230.212 OCCUPANT LOAD AND EGRESS CAPACITY See Occupancy Schedule this sheet for building occupant load Total egress capacity provided exceed occupant load. Refer to plans this sheet. DOOR SWING Doors serving an area required to have two (2) or more exits shall swing in the direction of egress travel (IBC, Sec. 1 008.1.2). EXITING Doors serving an area required to have two (2) or more exits shall swing in the direction of egress travel (IBC, Sec. 1 008.1.2). CODE SUMMARY INDICATES ONE-HOUR RATED CONSTRUCTION INDICATES TWO-HOUR RATED CONSTRUCTION INDICATES EGRESS PATH INDICATES FIRE EXTINGUISHER LOCATIONFEC EGRESS CAPACITY TAG OCCUPANT LOAD OCCUPANT CAPACITY B 32 24000 SF OCCUPANCY TAGNUMBER OF OCCUPANTS SPACE FUNCTION FROM TABLE 1004.1.1 AREA OF SPACE (net or gross) B = Business/Office S = Storage M = Mechanical A = Assembly LIFE SAFETY PLAN LEGEND DANDR ID GE DRE W WHITEHI T AR-19400087 ARC TEC STATE OF No. DND I NAA AII R EG I STERE DNDI NA AI HI TARC TECDANDRID GE DRE W WHITEREVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m CLIENT GSD DDW 08/17/2020 G002 CODE REVIEW 19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers 10505 N. College Avenue Brad Schoeff - Sr. Project Manager PH: 317-846-6611 Innovative Structural Solutions, P.A. 5279 Kyler Avenue, NE PH: 763-425-9960 Gooderum & Associates Engineering 874 Cheltenham Way PH: 317-506-8151 Indianapolis, IN 46280 Albertville, MN 55301 Avon, IN 46123 Extra Space Storage 9000 Keystone Crossing, Ste. 660 Jim Adams Indianapolis, IN 46240 PH: 317-663-8648 CIVIL ENGINEER STRUCTURAL ENGINEER MEP ENGINEER # DESCRIPTION DATE 07/14/21