HomeMy WebLinkAboutM002_Bid Addendum No. 2100 SF10 x 10197 SF10 x 2036 SF5 x 7.524 SF5 x 549 SF10 x 549 SF10 x 524 SF5 x 573 SF10 x 7.573 SF 10 x 7.549 SF10 x 549 SF10 x 5OFFICE
101
TELECOM
103BREAKROOM
102 WC
105
JANITOR
104
6" W.C.
S-2
140
10"Ø8"Ø8"Ø10"
WC10"Ø6"Ø MEF-5
150
EF-4
75
S-2
160
S-1
50
S-1
100
S-2
140
S-2
140
S-2
1408"ØS-2
140
14/12R-1
R-1
10"Ø 10"Ø
14/12
8"Ø
F-1
2.5 TON
T 8"Ø8"Ø
8"Ø
10"Ø
EF-1
75
M002
HVAC DETAILS,
AND SCHEDULES
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
JP
DRG
08/27/2020
200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage
900 Keystone Crossing, Ste. 230
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
# DESCRIPTION DATE
Weihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
Indianapolis, IN 46280
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
Albertville, IN 55301
PH: 763-425-9960
MEP ENGINEER
Gooderum & Associates Engineering
874 Cheltenham Way
David Gooderum, PE
Avon, IN 46123
PH: 317-506-8151
30° MAX
O
CONCENTRIC
TRANSITION MAX, 45
DEG. DIVERGING AND
60 DEG. CONVERGING
OFFSET. PROVIDE MINIMUM 2"
STRAIGHT SECTION AT EACH
END. MAX 30 DEG.
ECCENTRIC TRANSITION MAX,
30 DEG.
30° MAX
NOTE:
IN GENERAL, ELBOWS TO HAVE
FULL TURNING RADIUS (R=A).
WHERE "R" IS EQUAL TO OR
GREATER THAN "A" MINIMUM
RADIUS (R) = 4 INCHES.
R=A
A
DUCT CONSTRUCTION DETAILSB
45 DEG.
OCL CONNECTION
TAKE OFF. HAMMER
LOCKED OR FLANGED AND
FULLY SEALED
RECTANGULAR
DUCT
BRANCH
AIR FLOWV.D.
45 DEG. HIGH EFFICIENCY
TAKE OFF COMPLETELY
SEALED
ROUND SHEET METAL
DUCT TO DIFFUSER
118"
NOTE:
DOUBLE THICKNESS
TURNING VANES TO BE USED
WHERE NORMAL RADIUS
ELBOW IS IMPRACTICAL
& WHERE ELBOW IS WITHIN 5
FT OF A
BRANCH TAKE-OFF.AIR FLOWAGA GAS SHUT OFF, DIRT LEG
AND UNION. PROVIDE TREATED
WOOD BLOCKING AND
GALVANIZED CLAMP SUPPORT.
PLACE EXTRA ROOF
MEMBRANE BETWEEN BLOCK
AND ROOF MEMBRANE. TYP.3/4 PVC TRAPPED COND.
DRAIN. PROVIDE CLEAN OUT
AND CONCRETE SPLASH
BLOCK.
FILTERED FRESH AIR INTAKE
HOOD MAINTAIN MINIMUM OF
10'-0" FROM ALL EXHAUST
AND PLUMBING VENTS
3" MIN.
CUT ROOF ONLY AS NEEDED
FOR DUCT DROPS. PROVIDE
R-13 BATT INSULATION
PLACED ON REMAINING DECK
FOR SOUND ABSORPTION.
ELECTRICAL DISCONNECT
BY UNIT MANUFACTURER MAINTAIN MINIMUM OF 10'-0"
FROM EDGE OF ROOF
48" LONG SHEET METAL DROPS
LINED WITH 1" DUCT LINER SIZE TO
MATCH CURB OPENING.
FLEXIBLE DUCT CONNECTOR.
PROVIDE NEOPRENE CURB
TAPE AT DUCT CONNECTION
SEAL AIR TIGHT.
STEEL ANGLE FRAME BY STEEL
ERECTION CONTRACTOR COORDINATE
SIZES WITH STEEL SHOP DRAWINGS.
H NO SCALE
ROOF MOUNT RTU DETAIL
NO SCALE
E SCALE: 1/4" = 1'-0"
ENLARGED OFFICE HVAC PLAN N
GENERAL NOTES:
1. REFERENCE SHEET M001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
2. REFERENCE SHEET M002 FOR DETAILS AND
SCHEDULES.
OFFICE AREA FURNACE DETAILA
PROVIDE LINED SHEET METAL
RETURN AIR FURNACE BOX
UNDER ALL FURNACES. NO SIDE
FURNACE CONNECTIONS
ALLOWED.
MANUFACTURERS FILTER RACK
WITH 2" PLEATED MERV 8 FILTER.
PVC VENT AND COMBUSTION AIR
PIPING ROUTED TO CONCENTRIC
ROOF VENT. PITCH TOWARD
FURNACE MINIMUM 1/4" PER FOOT.
INSTALL PER MANUFACTURERS
INSTRUCTIONS.
PROVIDE OPEN SITE DRAIN
CONNECTION TO PROTECT
COMBUSTION BLOWER
TRAPPED PRIMARY AND
INDEPENDENT SECONDARY 3/4"
PVC DRAIN LINE. ROUTE
SECONDARY TO DRAIN PAN.
ROUTE PRIMARY DRAIN TO
INDIRECTION CONNECTION
AT HUB/DRAIN IN MECH
ROOM. MINIMUM SLOPE 1/4"
PER FOOT. SECURE LINE
AND TIE OFF AT DRAIN.
UPFLOW
FURNACE
16" MIN.
MATCHING WIDTH CASED EVAPORATOR
COIL SEALED TO FURNACE AND SUPPLY
AIR DUCT.
REFRIGERATION GRADE TYPE L
COPPER LINE SET WITH 1/2" WALL
ARMAFLEX SIZE PER
MANUFACTURE
AGA GAS VALVE, DIRT LEG AND
UNION CONNECTED TO FURNACE.
PROVIDE MINIMUM 1-1/2 DEEP
SEALED SECONDARY DRAIN PAN
WITH MOISTURE SWITCH. WIRE
SWITCH TO SHUT DOWN FURNACE IF
PRIMARY DRAIN FAILS
RA DUCT TO ATTIC SEAL AIR
TIGHT AT CEILING PENETRATION
SA/RA DUCTS
FLEXIBLE DUCT CONNECTOR
M
FRESH AIR DUCT WITH MOTORIZED
DAMPER INTERLOCKED TO
FURNACE BLOWER. PROVIDE
MANUAL VD AND BALANCE TO
SCHEDULED CFM.
NO SCALE
LAY-IN DIFFUSER DETAIL
NO SCALE D
SECURE FLEXIBLE DUCT TO
SUPPLY DIFFUSER ELBOW
FITTING WITH DRAWBANDS.
SHEET METAL ELBOW
SEAL ALL RIBS AND
CONNECTION TO
DIFFUSER NECK
SUPPLY DIFFUSER ACT CEILING
FLEX DUCT MAXIMUM LENGTH
SHALL NOT EXCEED 7'-0"
REFERENCE ARCHITECTURAL
REFLECTED CEILING PLAN AND
ELECTRICAL LIGHTING PLAN AND
COORDINATE INSTALLATION WITH ALL
CEILING ELEMENTS.
RA
DROP
E RTU-1 RA DROP DETAIL
SCALE: NONE
GALVANIZED DUCT HANGER
STRAP SECURED TO
STRUCTURE ABOVE.
FRAMED OPENING ON TOP
OF DUCT COVERED WITH
GALVANIZED WELDED WIRE
SCREEN. 20X20.
SECURE AND SEAL
DROP TO RTU CURB
FRAME.
BUTTER TOP OF
LINER FULL
PERIMETER OF
OPENING
MINIMUM 48" LINED DUCT
RUN OUT MOUNTED AS
HIGH AS POSSIBLE.
WITH ROOFING CONTRACTOR
COORDINATE LOCATION/TYPE
PITCH
POCKET
MOUNTED ON 2" SQUARE
AIR COOLED CONDENSER
SLOPE GALVANIZED EQUIPMENT RAIL
EQUIPMENT SUPPORTS LIKE PATE EQ-1
NEMA 3R DISCONNECT
SIZED AND INSTALLED PER
NEC. MOUNT TO SIDE OF UNIT
GFCI WHERE SHOWN ON
PLANS
MIN. 8"
VIBRATION PAD LIKE DIVERSITECH
#MP-2E ANTI-VIBRATION PAD
MECHANICALLY FASTENED
LINE SETS VIA CUSH CLAMPS
AND TREATED 4x4'S
REFRIGERANT TUBING WITH 1/2" WALL
MIN. ARMAFLEX INSULATION. INSULATION
LOCATED OUTDOORS SHALL BE PAINTED
WITH UV RESISTANT ARMAFLEX PAINT.
INVERTED TRAP, PITCH SUCTION LINE
TOWARD COMPRESSOR. PROVIDE OIL
RETURN TRAPS PER MANUFACTURES
PIPING RECOMMENDATIONS.
INSTALL ALL REFRIGERATION
SPECIALTIES AS INDICATED ON
EQUIPMENT SCHEDULES.
C SCALE: NONE
ROOF MOUNT ACCU DETAIL
WITH SLIP SHEET UNDER RAIL SET ON ROOF MEMBRANE
1 10/15/20BID ADDEN. 002
1
1
1
1
1
07/14/21