HomeMy WebLinkAboutM002_Bid Addendum No. 2100 SF10 x 10197 SF10 x 2036 SF5 x 7.524 SF5 x 549 SF10 x 549 SF10 x 524 SF5 x 573 SF10 x 7.573 SF 10 x 7.549 SF10 x 549 SF10 x 5OFFICE 101 TELECOM 103BREAKROOM 102 WC 105 JANITOR 104 6" W.C. S-2 140 10"Ø8"Ø8"Ø10" WC10"Ø6"Ø MEF-5 150 EF-4 75 S-2 160 S-1 50 S-1 100 S-2 140 S-2 140 S-2 1408"ØS-2 140 14/12R-1 R-1 10"Ø 10"Ø 14/12 8"Ø F-1 2.5 TON T 8"Ø8"Ø 8"Ø 10"Ø EF-1 75 M002 HVAC DETAILS, AND SCHEDULES REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m CLIENT JP DRG 08/27/2020 200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage 900 Keystone Crossing, Ste. 230 Jim Adams Indianapolis, IN 46240 PH: 317-663-8648 CIVIL ENGINEER STRUCTURAL ENGINEER # DESCRIPTION DATE Weihe Engineers 10505 N. College Avenue Brad Schoeff - Sr. Project Manager Indianapolis, IN 46280 PH: 317-846-6611 Innovative Structural Solutions, P.A. 5279 Kyler Avenue, NE Albertville, IN 55301 PH: 763-425-9960 MEP ENGINEER Gooderum & Associates Engineering 874 Cheltenham Way David Gooderum, PE Avon, IN 46123 PH: 317-506-8151 30° MAX O CONCENTRIC TRANSITION MAX, 45 DEG. DIVERGING AND 60 DEG. CONVERGING OFFSET. PROVIDE MINIMUM 2" STRAIGHT SECTION AT EACH END. MAX 30 DEG. ECCENTRIC TRANSITION MAX, 30 DEG. 30° MAX NOTE: IN GENERAL, ELBOWS TO HAVE FULL TURNING RADIUS (R=A). WHERE "R" IS EQUAL TO OR GREATER THAN "A" MINIMUM RADIUS (R) = 4 INCHES. R=A A DUCT CONSTRUCTION DETAILSB 45 DEG. OCL CONNECTION TAKE OFF. HAMMER LOCKED OR FLANGED AND FULLY SEALED RECTANGULAR DUCT BRANCH AIR FLOWV.D. 45 DEG. HIGH EFFICIENCY TAKE OFF COMPLETELY SEALED ROUND SHEET METAL DUCT TO DIFFUSER 118" NOTE: DOUBLE THICKNESS TURNING VANES TO BE USED WHERE NORMAL RADIUS ELBOW IS IMPRACTICAL & WHERE ELBOW IS WITHIN 5 FT OF A BRANCH TAKE-OFF.AIR FLOWAGA GAS SHUT OFF, DIRT LEG AND UNION. PROVIDE TREATED WOOD BLOCKING AND GALVANIZED CLAMP SUPPORT. PLACE EXTRA ROOF MEMBRANE BETWEEN BLOCK AND ROOF MEMBRANE. TYP.3/4 PVC TRAPPED COND. DRAIN. PROVIDE CLEAN OUT AND CONCRETE SPLASH BLOCK. FILTERED FRESH AIR INTAKE HOOD MAINTAIN MINIMUM OF 10'-0" FROM ALL EXHAUST AND PLUMBING VENTS 3" MIN. CUT ROOF ONLY AS NEEDED FOR DUCT DROPS. PROVIDE R-13 BATT INSULATION PLACED ON REMAINING DECK FOR SOUND ABSORPTION. ELECTRICAL DISCONNECT BY UNIT MANUFACTURER MAINTAIN MINIMUM OF 10'-0" FROM EDGE OF ROOF 48" LONG SHEET METAL DROPS LINED WITH 1" DUCT LINER SIZE TO MATCH CURB OPENING. FLEXIBLE DUCT CONNECTOR. PROVIDE NEOPRENE CURB TAPE AT DUCT CONNECTION SEAL AIR TIGHT. STEEL ANGLE FRAME BY STEEL ERECTION CONTRACTOR COORDINATE SIZES WITH STEEL SHOP DRAWINGS. H NO SCALE ROOF MOUNT RTU DETAIL NO SCALE E SCALE: 1/4" = 1'-0" ENLARGED OFFICE HVAC PLAN N GENERAL NOTES: 1. REFERENCE SHEET M001 FOR LEGENDS, ABBREVIATIONS, SPECIFICATIONS AND NOTES. 2. REFERENCE SHEET M002 FOR DETAILS AND SCHEDULES. OFFICE AREA FURNACE DETAILA PROVIDE LINED SHEET METAL RETURN AIR FURNACE BOX UNDER ALL FURNACES. NO SIDE FURNACE CONNECTIONS ALLOWED. MANUFACTURERS FILTER RACK WITH 2" PLEATED MERV 8 FILTER. PVC VENT AND COMBUSTION AIR PIPING ROUTED TO CONCENTRIC ROOF VENT. PITCH TOWARD FURNACE MINIMUM 1/4" PER FOOT. INSTALL PER MANUFACTURERS INSTRUCTIONS. PROVIDE OPEN SITE DRAIN CONNECTION TO PROTECT COMBUSTION BLOWER TRAPPED PRIMARY AND INDEPENDENT SECONDARY 3/4" PVC DRAIN LINE. ROUTE SECONDARY TO DRAIN PAN. ROUTE PRIMARY DRAIN TO INDIRECTION CONNECTION AT HUB/DRAIN IN MECH ROOM. MINIMUM SLOPE 1/4" PER FOOT. SECURE LINE AND TIE OFF AT DRAIN. UPFLOW FURNACE 16" MIN. MATCHING WIDTH CASED EVAPORATOR COIL SEALED TO FURNACE AND SUPPLY AIR DUCT. REFRIGERATION GRADE TYPE L COPPER LINE SET WITH 1/2" WALL ARMAFLEX SIZE PER MANUFACTURE AGA GAS VALVE, DIRT LEG AND UNION CONNECTED TO FURNACE. PROVIDE MINIMUM 1-1/2 DEEP SEALED SECONDARY DRAIN PAN WITH MOISTURE SWITCH. WIRE SWITCH TO SHUT DOWN FURNACE IF PRIMARY DRAIN FAILS RA DUCT TO ATTIC SEAL AIR TIGHT AT CEILING PENETRATION SA/RA DUCTS FLEXIBLE DUCT CONNECTOR M FRESH AIR DUCT WITH MOTORIZED DAMPER INTERLOCKED TO FURNACE BLOWER. PROVIDE MANUAL VD AND BALANCE TO SCHEDULED CFM. NO SCALE LAY-IN DIFFUSER DETAIL NO SCALE D SECURE FLEXIBLE DUCT TO SUPPLY DIFFUSER ELBOW FITTING WITH DRAWBANDS. SHEET METAL ELBOW SEAL ALL RIBS AND CONNECTION TO DIFFUSER NECK SUPPLY DIFFUSER ACT CEILING FLEX DUCT MAXIMUM LENGTH SHALL NOT EXCEED 7'-0" REFERENCE ARCHITECTURAL REFLECTED CEILING PLAN AND ELECTRICAL LIGHTING PLAN AND COORDINATE INSTALLATION WITH ALL CEILING ELEMENTS. RA DROP E RTU-1 RA DROP DETAIL SCALE: NONE GALVANIZED DUCT HANGER STRAP SECURED TO STRUCTURE ABOVE. FRAMED OPENING ON TOP OF DUCT COVERED WITH GALVANIZED WELDED WIRE SCREEN. 20X20. SECURE AND SEAL DROP TO RTU CURB FRAME. BUTTER TOP OF LINER FULL PERIMETER OF OPENING MINIMUM 48" LINED DUCT RUN OUT MOUNTED AS HIGH AS POSSIBLE. WITH ROOFING CONTRACTOR COORDINATE LOCATION/TYPE PITCH POCKET MOUNTED ON 2" SQUARE AIR COOLED CONDENSER SLOPE GALVANIZED EQUIPMENT RAIL EQUIPMENT SUPPORTS LIKE PATE EQ-1 NEMA 3R DISCONNECT SIZED AND INSTALLED PER NEC. MOUNT TO SIDE OF UNIT GFCI WHERE SHOWN ON PLANS MIN. 8" VIBRATION PAD LIKE DIVERSITECH #MP-2E ANTI-VIBRATION PAD MECHANICALLY FASTENED LINE SETS VIA CUSH CLAMPS AND TREATED 4x4'S REFRIGERANT TUBING WITH 1/2" WALL MIN. ARMAFLEX INSULATION. INSULATION LOCATED OUTDOORS SHALL BE PAINTED WITH UV RESISTANT ARMAFLEX PAINT. INVERTED TRAP, PITCH SUCTION LINE TOWARD COMPRESSOR. PROVIDE OIL RETURN TRAPS PER MANUFACTURES PIPING RECOMMENDATIONS. INSTALL ALL REFRIGERATION SPECIALTIES AS INDICATED ON EQUIPMENT SCHEDULES. C SCALE: NONE ROOF MOUNT ACCU DETAIL WITH SLIP SHEET UNDER RAIL SET ON ROOF MEMBRANE 1 10/15/20BID ADDEN. 002 1 1 1 1 1 07/14/21