HomeMy WebLinkAboutP002_Bid Addendum No. 2P002 PLUMBING DETAILS, AND SCHEDULES REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m CLIENT JP DRG 08/27/2020 200601EXTRA SPACE STORAGECARMEL DRIVE155 CARMEL DRIVE, CARMEL, INExtra Space Storage 900 Keystone Crossing, Ste. 230 Jim Adams Indianapolis, IN 46240 PH: 317-663-8648 CIVIL ENGINEER STRUCTURAL ENGINEER # DESCRIPTION DATE Weihe Engineers 10505 N. College Avenue Brad Schoeff - Sr. Project Manager Indianapolis, IN 46280 PH: 317-846-6611 Innovative Structural Solutions, P.A. 5279 Kyler Avenue, NE Albertville, IN 55301 PH: 763-425-9960 MEP ENGINEER Gooderum & Associates Engineering 874 Cheltenham Way David Gooderum, PE Avon, IN 46123 PH: 317-506-8151 ROOF LINE MIRO PIPE STAND ELBOW ELBOW REDUCER UNION APPLIANCE4" DIRT LEGWITH CAP (IF NECCESARY) FIELD VERIFY LENGTH AGA RATED GAS STOP GAS CONNECTION DETAIL ROOF GAS PIPING SUPPORT DETAIL MIRO #1.5 PIPE SUPPORT W/ ACCESSORIES ACCESSORIES - 1.5 pipe guide - 1.5 spacer - Support pad - Eternabond } 2-sided tape FLOW TEST DATA WATER SUPPLY TEST & GRAPH E 60 psi 56 psi 1000 gpm 8/4/20 300100 400 500 600 700 800 900 1000200 600200 800 1000 1200 1400 1600 1800 2000400 1200400 1600 2000 2400 700 800 900 1000800 FLOW RATE GPM 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 PRESSURE PSIGPICK X AXIS SCALE AS NEEDED S.S. CLAMPING RING NON-INSULATED PIPE SEALANT IN PIPE SLEEVE URETHANE OR DOW CORNING 1/2" (MIN.) FOAM-IN-PLACE RESILIENT FOAM PENETR. #3-6548 SILICONE RTV NON-INSULATED PIPE EPDM FLASHING BOOT WIRE MESH STAINLESS STEEL 1/4"x1/4" VENT THRU ROOF DETAILSNOW LOADING HGT. RQMTS.EXTEND VENTING PERCLEANOUT DETAIL HW CW EWH VALVE TANK DRAIN 2" DRAIN PAN TERMINATE RELIEF OVER DRAIN PAN SHELF MOUNTED WATER HEATER INSULATED 3/4" HW SUPPLY WATER HEATER DETAIL TMV THERMOSTATIC MIXING VALVE COLD WATER EXPANSION TANK FACTORY SUPPLIED HEAT TRAP NIPPLES TYPICAL 110 DEG. WATER TEMPERATURE GAGE LOCATION AT FLOOR DRAIN TERMINATE 3/4" DRAIN 3/4" MOP SINK (ATTACH SHELF TO STRUCTURE ABOVE) +7'-6"AFF FLOOR DRAIN ASME TEMPERATURE RELIEF VALVE AND PRESSURE 147 & 155 WEST CARMEL DRIVE CARMEL, INDIANA CARMEL WATER DEPARTMENT STATIC PRESSURE RESIDUAL PRESSURE FLOW RATE GPM PERFORMED BY: DATE: LOCATION: M.J. X FL. ADAPTER ALL THR. ROD WASHER TIE BOLT "J" BOLT OR HEX NUT & THRUST BLOCK (PER NFPA 24) FLOOR D.I.P. RISER BY OTHERS SLEEVE AND SEAL SLAB PENETRATION PER NFPA 13 U.G. PIPING TO 5 FEET PAST FOUNDATION SEE CIVIL PLAN FOR CONTINUATION FIRE SPRINKLER SERVICE DETAILF G H A C DNO SCALE NO SCALE NO SCALE NO SCALE NO SCALE NO SCALE BUILDING ISOMETRIC DIAGRAM NO SCALE1 MS 3"VTR FD LAV WC SK 3"W SEE CIVIL SHEETS FOR CONTINUATION 1-1 / 2"V 2" V 2"V 2"V 3"W 3" W 3"W 3" W GCO 2"W CO 3"W 3"VTR 2"VCO CO DETAIL IS FOR REFERENCE ONLY, PROR TO INSTALLATION, COORDINATE INSTALLATION WITH SITE CONTRACTOR AND LOCAL WATER UTILITY. SYSTEM TO DOMESTIC 3/4" INLET CARMEL WATER SERVICE DETAIL - 3/4" SCALE: NONE 3/4" CARMEL WATER 3/4" REMOTE READ METER WITH LOCKABLE VALVES. COORDINATE WITH PUBLIC UTILITY. SECURE ALL PIPING, FITTINGS AND VALVES TO WALL OR FLOOR PER SPECIFICATIONS. B 18" REDUCED PRESSURE ZONE BACKFLOW PREVENTER: WATTS MODEL 009M2QTS CAST BRONZE CONSTRUCTION WITH QUARTER TURN FULL-PORT BALLVALVES. 30"RISING STEM BALL VALVES 3/4" 3/4" FLOOR DRAIN 1 10/15/20BID ADDEN. 002 1 07/14/21