Loading...
HomeMy WebLinkAboutA001_Bid Addendum No. 5BASE MATERIAL CONCRETE OR CONCRETE BLOCK GYPSUM CONCRETE OR CONCRETE BLOCK GYPSUM BASIS OF DESIGN: HILTI CONSTRUCTION CHEMICALS, INC. PENETRATING ITEM METAL PIPE STEEL, COPPER, CONDUIT OR EMT (SLEEVED OR UNSLEEVED) STEEL, COPPER, CONDUIT OR EMT STEEL, COPPER, CONDUIT OR EMT STEEL, COPPER, CONDUIT OR EMT STEEL, COPPER, CONDUIT OR EMT (SLEEVED) STEEL, COPPER, CONDUIT OR EMT INSULATED METAL PIPES STEEL, COPPER, CONDUIT OR EMT W/ GLASSFIBER INSULATION (SLEEVED OR UNSLEEVED) STEEL, COPPER, CONDUIT OR EMT W/ AB/PVC INSULATION (SLEEVED OR UNSLEEVED) STEEL, COPPER, CONDUIT OR EMT PIPE W/ GLASSFIBER INSULATION IN A SLEEVE STEEL, COPPER, CONDUIT OR EMT W/ GLASSFIBER INSULATION STEEL, COPPER, CONDUIT OR EMT W/ AB/PVC INSULATION STEEL, COPPER, CONDUIT OR EMT W/ GLASSFIBER INSULATION (SLEEVED OR UNSLEEVED) STEEL, COPPER, CONDUIT OR EMT PIPE W/ GLASSFIBER INSULATION IN A SLEEVE FIRE RATING 3 HR 4 HR 1 OR 2 HR 1 OR 2 HR 2 HR 4 HR 2 HR 3HR 4 HR 1 OR 2 HR 1 OR 2 HR 1 OR 2 HR 4 HR UL SYSTEM NO. CAJ 1155 CAJ 1226 WJ 1042 WL 1054 WL 1085 WL 1058 WL 1110 CAJ 5091 CAJ 5090 WJ 5029 WL 5029 WL 5028 WL 5025 WL 5073 APPROVED EQUALS: PRODUCT OF EQUIVALENT CHARACTERISTICS UL COMPLIANT WITH UL 1479 AND UL 2079, ASTM E1339. BASIS OF DESIGN HILTI PRODUCT FS-ONE FS ONE FS ONE FS ONE FS ONE FS ONE FS ONE FS ONE FS ONE FS ONE FS ONE FS ONE FS ONE W/ COLLAR FS ONE CONCRETE OR CONCRETE BLOCK GYPSUM CONCRETE OR CONCRETE BLOCK GYPSUM JOINTS CONCRETE BLOCK WALL TO METAL DECK (TOP OF WALL) GYPSUM WALL TO METAL DECK (TOP OF WALL TO ROOF) D13/A601 (TOP OF WALL TO FLOOR) PLASTIC & GLASS PIPE PVC, CPVC (CLOSED SYSTEM ONLY) PVC, CPVC , ABS, FRPP GLASS PIPE MAX 6" PVC, CPVC, ABS, FRPP (IN A SLEEVE) PVC, CPVC (CLOSED SYSTEM ONLY) PVC, CPVC, ABS, FRPP (CLOSED SYSTEM ONLY) 2 HR 1 OR 2 HR 1 OR 2 HR 3 HR 3 HR 3 HR 3 HR 1 OR 2 HR 1 OR 2 HR HWD-0008 HWD-1011 HWD-1003/-1011 CAJ 2141 CAJ 2109 CAJ 2118 CAJ 2110 WL 2098 WL 2078 WL 2075 FS ONE CP 601 OR FS ONE FS ONE CP 642 FS ONE CP 642 FS ONE CP 642 FS ONE SCOPE DRAWINGS AND SPECIFICATIONS, AS DEFINED BY THE INDIANA CONSTRUCTION INDUSTRY COUNCIL’S GUIDELINES, A. THE CONTRACTOR SHALL OBSERVE THE FOLLOWING: NOTHING SET FORTH IN THESE DRAWINGS SHALL RELEASE ANY CONTRACTOR FROM RESPONSIBILITY TO PROVIDE APPROPRIATE QUANTITIES, FIELD MEASUREMENTS, DIMENSIONAL STABILITY, INSTALLATION, ANCHORAGE AND COORDINATION WITH OTHER TRADES, OR WAIVE THE CONTRACTOR'S RESPONSIBILITY TO IDENTIFY AND RESOLVE DEVIATIONS FROM THE REQUIREMENTS OF THE CONTRACT DOCUMENTS, OR WAIVE THE CONTRACTOR'S RESPONSIBILITY TO ALERT THE ARCHITECT TO ERRORS OR OMISSIONS CONTAINED THEREIN. CONTRACTOR SHALL VERIFY IN THE FIELD ALL EXISTING APPLICABLE CONDITIONS AND DIMENSIONS SHOWN ON THE DRAWINGS AND AS PERTINENT TO THE INTENT OF THESE DRAWINGS. ANY DISCREPANCY DISCOVERED SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK AFFECTED BY, OR RELATED TO, SUCH DISCREPANCY. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH, OR CAUSED BY FAILURE TO COMPLY WITH REQUIREMENT. CONTRACTOR SHALL REVIEW IN ADVANCE ALL PORTIONS OF THE WORK TO VERIFY THAT THE WORK WILL NOT PROHIBIT COMPLETION OF THE PROJECT AS INTENDED IN THESE CONTRACT DOCUMENTS. ANY QUESTIONS SHALL BE PROMPTLY REFERRED TO THE ARCHITECT FOR RESOLUTION. CONTRACTOR SHALL REFER TO THE PROJECT MANUAL FOR CLEANING AND DISPOSAL REQUIREMENTS. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL SURFACES AND FINISHES AT INTERIOR AND EXTERIOR OF BUILDING. DAMAGED SURFACES AND FINISHES RESULTING FROM THE PERFORMANCE OF THE WORK SHALL BE REPAIRED AT NO COST TO THE OWNER BY THE RESPONSIBLE CONTRACTOR TO MATCH EXISTING TO THE SATISFACTION OF THE OWNER. CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WITH ALL ASPECTS OF THE WORK, EVEN THOSE AREAS DESIGNATED TO BE PROVIDED BY OTHERS. THIS FAMILIARIZATION INCLUDES FULL AND COMPLETE UNDERSTANDING OF THE WORK DESCRIBED ON ALL SHEETS OF THE DRAWINGS AND IN ALL SECTIONS OF THE PROJECT MANUAL. FAILURE BY THE CONTRACTOR TO BECOME COMPLETELY FAMILIAR AND COGNIZANT OF ALL ASPECTS OF THE WORK SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO PROVIDE MATERIALS, ASSEMBLIES, OR SERVICES INDICATED IN THE CONTRACT DOCUMENTS. B. THE CONTRACTOR SHALL PROVIDE THE FOLLOWING: ALL MATERIAL AND EQUIPMENT OF INDUSTRY STANDARD QUALITY, SPECIFIED OR NOT, AND WITH THE LIMITATION OF THE CONTRACT DOCUMENTS TO CAUSE THE INSTALLATION TO FUNCTION IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED PROJECT. ALL MATERIAL NECESSARY FOR EQUIPMENT TO FUNCTION IN A NORMAL AND ACCEPTABLE MANNER. ALL WORK REQUIRED TO CAUSE CONTRACTOR’S OPERATIONS TO FIT AND COORDINATE WITH OTHER TRADES. ALL WORK REQUIRED TO COMPLY WITH GOVERNING CODES WITH RESPECT TO CONTRACTOR’S ACTIVITY, EXCEPT FOR DESIGN CRITERIA INVOLVING CAPACITIES AND BASIC DESIGN. WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE SIZING OF INTERCONNECT FACILITIES, SUCH AS DUCTS AND WIRING IN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE SPECIFIED CAPACITIES OF THE EQUIPMENT. WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL GOVERN THE WORK. ALL UNSPECIFIED FIXTURES, ACCESSORIES AND / OR EQUIPMENT PROVIDED BY THE CONTRACTOR SHALL HAVE CUT SHEETS / DRAWINGS SUBMITTED TO THE ARCHITECT FOR APPROVAL. GENERAL PROJECT NOTES A. DO NOT SCALE THE DRAWINGS. REFER DISCREPANCIES TO ARCHITECT FOR FINAL DECISIONS. B. ALL DIMENSIONS SHOWN ARE TOFACE OF STUD TO FACE OF STUD UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATED AS "CLR OR "CLEAR" INDICATE A CLEAR DIMENSION FROM FACE OF FINISH TO FACE OF FINISH. C. PROVIDE BRACING AND WOOD BLOCKING AS REQUIRED IN WALLS SUPPORTING CASEWORK, TACKBOARDS, MARKERBOARDS, RESTROOM ACCESSORIES, ETC. D. SEAL ALL JOINTS BETWEEN DISSIMILAR MATERIALS. E. ALL GYPSUM WALLBOARD IS 5/8" TYPE "X" UNLESS NOTED OTHERWISE. PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM WALLBOARD IN LOADING BAY, JANITOR CLOSETS, AND RESTROOMS. F. WHERE MOUNTING HEIGHTS ARE NOT INDICATED, MOUNT INDIVIDUAL UNITS OF WORK AT INDUSTRY RECOGNIZED STANDARD MOUNTING HEIGHTS, ADA AND ANSI A117.1 FOR THE PARTICULAR APPLICATION AND REFER QUESTIONABLE MOUNTING HEIGHT CHOICES TO ARCHITECT FOR FINAL DECISIONS. G. COORDINATE ENGINEERING DRAWINGS WITH ARCHITECTURAL DRAWINGS AND FIELD CONDITIONS, AND REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT. H. CONFLICTS BETWEEN SPECIFICATIONS AND DRAWINGS SHALL BE COMMUNICATED TO THE ARCHITECT FOR RESOLUTION PRIOR TO COMMENCEMENT OF THE WORK. I. SUPPLY, COORDINATE, AND INSTALL ACCESS DOORS, PANELS AND HATCHES IN CEILINGS, WALLS, AND FLOORS; AND NOTIFY ARCHITECT OF ANY CONFLICTS WITH FEATURES SHOWN ON DRAWINGS. J. PROVIDE WATER ROUGH-IN AND ELECTRICAL CONNECTIONS FOR OWNER- PROVIDED EQUIPMENT IN COMPLIANCE WITH MEP DRAWINGS. K. PROVIDE SLIP CHANNELS AT ALL LOCATIONS WHERE WALLS EXTEND TO A STRUCTURAL MEMBER ABOVE. L. DOORS ARE TO BE INSTALLED 4" FROM CORNER TO EDGE OF FRAME TYPICAL. GENERAL PLAN NOTES MATERIALS LEGEND EARTH NOTE: PATTERNS SHOWN REPRESENT CUT MATERIALS IN PLAN OR SECTION, UNLESS NOTED OTHERWISE BELOW. GRANULAR FILL SAND, GROUT AS NOTED CAST-IN-PLACE CONCRETE PRECAST CONCRETE, CAST STONE STONE: LIMESTONE, GRANITE, MARBLE OR AS NOTED TERRA COTTA, STRUCTURAL CLAY TILE CONCRETE MASONRY UNIT BRICK MASONRY METAL: TYPE AS NOTED METAL: ROLLED SHAPES GLASS FIBER REINFORCED CONCRETE SIDING OR TRIM SHEATHING: GYPSUM, OR AS NOTED AIR BARRIER SYSTEM ACOUSTICAL CEILING TILE TILE: CERAMIC, QUARRY, UNO CARPET, CARPET TILE (DETAIL) GRATING RESINOUS FLOORING: TERRAZZO, TROWEL-ON, UNO GRATING SHOWN IN PLAN INSULATED GLASS: (SMALL SCALE) INSULATED GLASS: (DETAIL) MEMBRANE: WATERPROOF, ROOF, DAMPPROOFING WOOD FRAMING / BLOCKING: CONTINUOUS FINISHED WOOD SHOWN CUT AND ELEVATION ENGINEERED WOOD: GLUE LAMINATED WOOD FLOOR, WOOD SHINGLES, OR SIDING WOOD SHIM PARTICLEBOARD PLYWOOD EIFS SPRAYED FIREPROOFING SHOWN ON ROLLED SHAPE BATT INSULATION: THERMAL OR ACOUSTICAL, UNO RIGID INSULATION: THERMAL, ACOUSTICAL, OR SHAFTING GYPSUM WALL BOARD PLASTER ON METAL LATH SYMBOLS LEGEND (DETAIL VIEWS) (ELEVATION VIEWS)A101 1 SIM 1i 1'-0" Room Name XXXXX DETAIL NUMBER SHEET NUMBER DETAIL CALLOUT ELEVATION NUMBER SHEET NUMBER EXTERIOR ELEVATION TAG SECTION NUMBER SHEET NUMBER SECTION MARKER ATTRIBUTE WALL TYPE WALL TAG CEILING TYPE CEILING HEIGHT CEILING TAG 7 2 DOOR ID NUMBER REFER TO DOOR SCHEDULE SHEET ROOM NAME ROOM NUMBER ROOM TAG KEYED NOTE / PLAN NOTE DEMOLITION NOTE GLAZING TYPE NEW CONSTRUCTION EXISTING CONSTRUCTION DEMOLISHED CONSTRUCTION COL COLUMN GRID CONTROL JOINT SEALANT AND BACKER ROD KIT OF PARTS NOTE 000000.00 TX WINDOW TYPEX GL-X 1/ A101 1 A101 ELEVATION NUMBER SHEET NUMBER INTERIOR ELEVATION TAG SPEC SECTION REFERENCE NOTE NUMBERA101 SIM1 TOILET ACCESSORY FX FURNITURE/EQUIPMENT TAGXXX1 HR W1A.S Room Name XXXXX Floor Wall Base FINISH TAG FLOOR FINISH WALL FINISH BASE FINISH TOILET ACCESSORY MOUNTING HEIGHTS 1' - 0"3' - 6" 33" TO 36"17" - 19"8" GRAB BARS TOILET PAPER DISPENSER SANITARY NAPKIN DISPOSAL WALL -MOUNTED OR FLOOR MOUNTED WATER CLOSET GRAB BARS 1' - 0" 3' - 0"34" MAX1' - 6"17" TO 19" 1' - 3" PIPE INSULATION FOR ADA COMPLIANCE 29" MIN CLEAR40" MAX CLEAR 3' - 0"1' - 6"42" MAX TO CONTROL3' - 5" 1' - 6"42" MAX TO CONTROLNOTE: REFER TO PROJECT MANUAL FOR COMPLETE TOILET ACCESSORY SPECIFICATIONS. FIRE STOPPING SCHEDULE AND DETAILS WALL CONSTRUCTION FIRE SEAL MATERIAL AS REQUIRED FOR FIRE RATING FILLING ANNULAR SPACE PENETRATING ITEM ABBREVIATIONS CL. CARPET D.E.F.S. CPT. C.W. C.M. ACOUSTICAL AMERICANS W/DISABILITIES ACT AMERICANS W/DISABILITIES ACT ACCESSIBILITY GUIDELINES ARCHITECT/ENGINEER C.I.P. C.F.C.I. B.O.W. A.P. A.V. A/E ADAAG ADA ACOUS. FINISH(ED) TBD TO BE DETERMINED WELDED WIRE FABRIC TEMPORARY TEMPERED TOP OF MASONRY TOP OF DECK TOP OF STEEL VERIFY IN FIELD VINYL COMPOSITION TILE WIDE/WIDTH WATER CLOSET TECHNICAL TOP OF CURB TELEPHONE TYPICAL TOP OF WALL TOP OF PAVEMENT TONGUE AND GROOVE UTILITY UNIT VENTILATOR VERTICAL UNLESS NOTED OTHERWISE WATER HEATER WOOD WITH VESTIBULE WEIGHT ANGLE MISCELLANEOUS CENTER LINE NUMBER WITHOUT # W.W.F. WD. W.H. WT. W/O FINISH OPENING FLOOR FLUORESCENTFLUOR. F.O. FLR. W.C. VIF W W W/ VEST. V.C.T. UTIL. U.N.0. U.V. V VERT. T&G T.M. T.S. T.P. TYP. U T.W. T.D. TMPRD. TEMP. T.C. TECH. TEL. TACK BOARD REFLECTED CEILING PLAN REFERENCE ROOF DRAIN RADIUS REFLECTED RIGHT HAND RESILIENT ROOM REINFORCED ROUGH OPENING SIMILAR SHEET SECTION SOAP DISPENSER SCHEDULE SQUARE FEET SQUARE SPECIFICATION SYMMETRICAL SUSPEND(ED) STRUCTURAL STORAGE STANDARD STAINLESS STEEL THICKNESS CENTERLINE E FINISH SYSTEM EXPOSED ELECTRICAL CONTRACTOR ELECTRICAL PANEL EXTERIOR INSULATION FAN COIL UNIT AND EQUIPMENT FURNISHINGS, FIXTURES FINISH FLOOR ELEVATION EACH ELEVATION EXPANSION JOINT EQUAL ENGINEER ELEVATOR/ELEVATION EXISTING EXTERIOR ELECTRIC WATER COOLER EQUIPMENT FABRICATE/FABRICATOR FIRE EXTINGUISHER FIRE HOSE CABINET FLOOR DRAIN FIRE EXTINGUISHER CABINET ELECTRIC/ELECTRICAL EXP. F.F.&E. FIN. F.H.C. F.F.E. F.E.C. F.E. F F.C.U. FAB. F.D. EXT. EQ. EQUIP. EXIST. E.W.C. E.P. ENGR. ELEV. E.J. EL. ELEC. E.I.F.S. E.C. EA. SHT. T.B. SUSP. SYM. T T. SIM. SQ. S.S. SPEC. STRUCT. STOR. STD. R.O. S S.D. SECT. SCHED. S.F. R.D. REF. REFL. RESIL. R.H. RM REINF. COLD WATER CONSTRUCTION MANAGER FINISH SYSTEM COORDINATE CONCRETE COLUMN CEILING CONCRETE MASONRY UNIT CONTRACTOR CONTINUOUS CERAMIC TILE CONSTRUCTION DETAIL DEPARTMENT DRINKING FOUNTAIN DOWN DIMENSION DISPENSER DRY MARKER BOARD DIAMETER DRAWING DOWNSPOUT D DN DWG. DS D.M.B. DIM. DISP. DEPT. DET. D.F. DIA. CONT. C.T. COOR. CONTR. C.M.U. CONC. CONST. COL. CLG. R.C.P. R R A AUDIO/VISUAL ACCESS PANEL BOTTOM OF WALL CONTRACTOR FURNISHED- CONTRACTOR INSTALLED CAST-IN-PLACE ADJUSTABLE AIR CONDITIONING ACOUSTICAL CEILING TILE ALTERNATE ALUMINUM ABOVE FINISHED FLOOR ARCHITECT/ARCHITECTURAL BOARD BASEMENT BUILDING BITUMINOUS CABINET CORNER GUARD CONTROL JOINT B C C.G. C.J. CAB. BLDG. BSMT. BITUM. BD. ALUM. ARCH. A.F.F. ALT. A.C.T. ADJ. A/C ACOUSTICAL CEILING PANELACP CLEAR(ANCE)CLR CMP COMPOSITE METAL PANEL FIRE-RESISTIVEF-R TOP OFT/O B/O BOTTOM OF STEELSTL. M.D.F. MB. M.C. PROPERTY LINE OWNER FURNISHED- OWNER INSTALLED OWNER FURNISHED- CONTRACTOR INSTALLED LENGTH MARKER BOARD LONG LEG OUT LONG LEG VERTICAL LONG LEG HORIZONTAL MECH./ELECT./PLUMBING MEDIUM DENSITY FIBERBOARD MECHANICAL CONTRACTOR METAL MECHANICAL MAXIMUM MINIMUM MISCELLANEOUS MANHOLE MANUFACTURER(ING) MASONRY OPENING NUMBER NOT TO SCALE NOT IN CONTRACT NO APPLIED FINISH ON CENTER OVER ALL OPENING OPPOSITE HAND OUTSIDE DIAMETER PLASTER PAIR PARTICLE BOARD PLYWOOD PREFABRICATED PLASTIC LAMINATE QUARRY TILE PAINTED POUND LAVATORY LEFT HAND Q Q.T. P. LAM PLAS. PT. BD. PR. PWD. PREFAB. PTD. P.L. O.F.O.I. OPG. O.H. P O.F.C.I. O.C. O.A. O.D. O L M.O. MTL. N N.A.F. N.T.S. NO. N.I.C. M.E.P. MECH. MFR. MISC. MIN. M.H. L.L.V. M MAX. L L.L.O. L.L.H. LAV. LB. L.H. OPPOSITEOPP. GENERAL CONTRACTOR HEIGHT HOT WATER FACE OF BRICK FACE OF CONCRETE FACE OF BLOCK FIREPROOF FACE OF STUD FACE OF GYPSUM BD. FACE OF FINISH FIELD VERIFY GENERAL GAUGE GLASS FOOT/FEET HARDWARE HOSE BIBB HEIGHT HOLLOW METAL HORIZONTAL HEATING, VENTILATION & A.C. GYPSUM WALL BOARD GA. HT. H.W. HVAC HORIZ. HB HDWR. H.M. G.W.B./GWB H H. G.C. GEN. GL. F.O.G. G F.V. F.O.S. FPRF. FT. F.O.B. F.O.BR. F.O.C. F.O.F. INFORMATION INCANDESCENT INSIDE DIAMETER INTERIOR INSULATION INCAN. INFO. INT. INSUL. I I.D. JOIST BEARING JANITOR CLOSET JANITOR JOINT J.C. JST. BRG. JT. J JAN. FIRE RATING REF. DESIGN No. R-VALUE U-VALUE E1 BRICK ON METAL STUD. 0.52 COL REFER TO WALL SECTIONS 3" TYP. FIRE RATING REF. DESIGN No. R-VALUE U-VALUE E2 CMU ON METAL STUD. 0.52 COL REFER TO WALL SECTIONS 3" TYP. 1' - 2" AIR SPACE [04 00 00-D7] FLUID-APPLIED MEMBRANE AIR BARRIER SHOWN DASHED [07 27 26-A1] SCREW -ATTACHED MASONRY VENEER ANCHOR, THERMAL (HB THERMAL 2-SEAL WING NUT AND 2X-HOOK TIE OR EQUAL) [04 00 00-C8] INSULATION TYPE 2 -STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2] SCREW -ATTACHED MASONRY VENEER ANCHOR, THERMAL (HB THERMAL 2-SEAL WING NUT AND 2X-HOOK TIE OR EQUAL) [04 00 00-C8] FLUID-APPLIED MEMBRANE AIR BARRIER SHOWN DASHED [07 27 26-A1] 5/8" GLASS-MAT GYPSUM SHEATHING -TAPE ALL SEAMS [06 16 00-A2] 5/8" TYPE "X" GYPSUM WALLBOARD [09 29 00-A8] 6" METAL STUD [05 41 00-A4] EXTERIOR WALL TYPES SCHEDULE INSULATION TYPE 2 -STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2] FIRE RATING REF. DESIGN No. R-VALUE U-VALUE E3 FORMED METAL PANEL ON METAL STUD 0.52 NOTE: CONTRACTORS OPTION TO SUBSTITUTE COMPOSITE NAIL BASE INSULATED WALL SHEATHING IN LIEU OF SEPARATE GYP SHEATHING, RIGID AND PLYWOOD. REFER PROJECT MANUAL. FORMED METAL WALL PANELS - PREFINISHED [07 41 14-A1] FLUID-APPLIED MEMBRANE AIR BARRIER SHOWN DASHED [07 27 26-A1] 1' - 2" INSULATION TYPE 4 -KRAFT FACED FIBERGLASS BATT INSULATION, R19 MIN. [07 21 00-A4] 5/8" TYPE "X" GYPSUM WALLBOARD [09 29 00-A8] 6" METAL STUD [05 41 00-A4] INSULATION TYPE 4 -KRAFT FACED FIBERGLASS BATT INSULATION, R19 MIN. [07 21 00-A4] 6" METAL STUD [05 41 00-A4] 6" METAL STUD [05 41 00-A4] 4" X 8" X 16" GROUND FACE CMU [04 22 00-D1] INSULATION TYPE 4 -KRAFT FACED FIBERGLASS BATT INSULATION, R19 MIN. [07 21 00-A4] STANDARD BRICK -3/8" JOINT [04 20 00-A1] 6" 4 3/8" 3 5/8" 6" 3 1/8" 3 5/8"6" 6 5/8" 7/8" 1' - 1 1/2" COL REFER TO WALL SECTIONS 3 1/2" TYP. NOTE: CONTRACTORS OPTION TO SUBSTITUTE COMPOSITE NAIL BASE INSULATED WALL SHEATHING IN LIEU OF SEPARATE GYP SHEATHING, RIGID AND PLYWOOD. REFER PROJECT MANUAL. 5/8" GLASS-MAT GYPSUM SHEATHING -TAPE ALL SEAMS [06 16 00-A2] 5/8" GLASS-MAT GYPSUM SHEATHING -TAPE ALL SEAMS [06 16 00-A2] FIRE RATING REF. DESIGN No. R-VALUE U-VALUE E4 CMU ON CMU 0.52 7 5/8" 3 3/8" 3 5/8" 1' - 2 5/8" 4" X 8" X 16" GROUND FACE CMU [04 22 00-D1] AIR SPACE [04 00 00-D7] INSULATION TYPE 2 -STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2] 8" X 8" X 16" GROUND FACE CMU [04 22 00-D3] FIRE RATING REF. DESIGN No. R-VALUE U-VALUE E5 1 HR U-425 1 HR RATED METAL STUD WALL 0.52 COL REFER TO WALL SECTIONS 3" TYP. 5/8" TYPE "X" GYPSUM WALLBOARD [09 29 00-A8] 6" METAL STUD [05 41 00-A4] INSULATION TYPE 4 -KRAFT FACED FIBERGLASS BATT INSULATION, R19 MIN. [07 21 00-A4] 6" NOTE: EXTERIOR FACADE OUTSIDE OF SHEATHING VARIES, REFER TO EXTERIOR ELEVATIONS. 5/8" GLASS-MAT GYPSUM SHEATHING -TAPE ALL SEAMS [06 16 00-A2] DIRECTION DEPENDS ON SIDING ORIENTATION -REFER TO ELEVATIONS 6" LIGHT GAUGE ZEE [05 40 00-D6] INSULATION TYPE 2 -STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2]DANDR ID GE DRE W WHI TEHI T AR-19400087 ARC TEC STATE OF No. DNDI NAA AII R E G I STERE DNDI NA AI HI TARC TECDANDRID GE DRE W WHITEREVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m CLIENT GSD DDW 09/11/2020 A001 GENERAL NOTES, SYMBOLS, LEGENDS AND EXTERIOR WALLS 19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers 10505 N. College Avenue Brad Schoeff - Sr. Project Manager PH: 317-846-6611 Innovative Structural Solutions, P.A. 5279 Kyler Avenue, NE PH: 763-425-9960 Gooderum & Associates Engineering 874 Cheltenham Way PH: 317-506-8151 Indianapolis, IN 46280 Albertville, MN 55301 Avon, IN 46123 Extra Space Storage 9000 Keystone Crossing, Ste. 660 Jim Adams Indianapolis, IN 46240 PH: 317-663-8648 CIVIL ENGINEER STRUCTURAL ENGINEER MEP ENGINEER SPECIALTY ACCESSORY SCHEDULE TYPE ITEM MFR / MODEL REMARKS PROVIDED BY INSTALLED BY T1 24"W X 36"T MIRROR BOBRICK B-290 2436 SATIN STAINLESS FINISH T2 GRAB BARS (3 PIECE) BOBRICK B-6806 SERIES 36", 42" AND 18" VERTICAL T3 TOILET PAPER DISPENSER - DOUBLE ROLL BOBRICK B-2892 19" MIN. A.F.F. TO C.L. - SURFACE MOUNTED T4 SOAP DISPENSER BOBRICK B-2111 ADA COMPLIANT T5 HAND DRYER BOBRICK B-3944 52-3/4" TO TOP - SURFACE MOUNTED SCALE: 1" = 1'-0"1 WALL PENETRATION # DESCRIPTION DATE 2 BID ADDEN. 005 03/24/2021 2 07/14/21