Loading...
HomeMy WebLinkAboutA101_Bid Addendum No. 1UP 00 SF0 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10197 SF10 x 2024 SF5 x 549 SF10 x 5147 SF10 x 15147 SF10 x 15145 SF10 x 1573 SF10 x 7.573 SF10 x 7.573 SF10 x 7.572 SF10 x 7.536 SF5 x 7.524 SF5 x 549 SF10 x 549 SF10 x 599 SF10 x 1099 SF10 x 1049 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 5153 SF10 x 15 153 SF10 x 15151 SF10 x 1553 SF0 x 2549 SF10 x 549 SF10 x 599 SF10 x 1024 SF5 x 5147 SF10 x 1573 SF10 x 7.573 SF10 x 7.573 SF10 x 7.549 SF10 x 549 SF10 x 5100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10100 SF10 x 10101099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1099 SF10 x 1049 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 549 SF10 x 524 SF5 x 549 SF10 x 549 SF10 x 599 SF10 x 1099 SF10 x 10252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25252 SF10 x 25153 SF10 x 15 153 SF10 x 15252 SF10 x 251510249 SF10 x 25253 SF10 x 25157 SF10 x 1598 SF10 x 1049 SF10 x 549 SF10 x 54191099 SF10 x 1049 SF10 x 524 SF5 x 549 SF10 x 5A 1 A.1 B B.1 C C.1 D 2 3 4 5 6 7 8 9 10 11 12 13 1414 15 16 17 OFFICE 101 ELEC. 106 STAIR 108 01A20101A20203 A201 SPRINKLER 107 ELEV. 109 20' - 0" 20' - 0" 20' - 0" 60' - 0"20' - 0"20' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 22' - 10" 27' - 10" 6' - 8" 8' - 7" 12' - 7"8' - 5" 9' - 10" 8' - 10" 9' - 3"160' - 0"A110 01 A110 03 02A20102A20201 A301 04 A301 03 A301 01 A302 02 A302 02 A301 03 A302 TELECOM 103 STORAGE UNITS 100 CONC P2 1 10' - 4"CORRIDOR 1109' - 11" 10' - 4"6' - 6" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"180' - 0"S1 S2 S3 S5S1S2EX108108 EX1107' - 7 5/8" 12' - 4 1/2" 8' - 2 1/4" 29' - 10 3/4" 64' - 0" 8' - 0" 60' - 0" 7' - 11 7/8" 4' - 0" 16' - 0 1/8" 4' - 0" 15' - 9" 4' - 0"52' - 6 5/8" 6' - 11 3/8" 4' - 0"4' - 0"15' - 9" 4' - 0" 15' - 11 7/8" 4' - 0" 36' - 0 1/4" 4' - 0" 96' - 3" 4' - 0" 60' - 8 1/4"50' - 4 3/4" 12' - 11 1/8" 10' - 4" 19' - 11 1/8" 7' - 10" 16' - 3 1/8"19' - 10 3/4"3 4 4 5 5 5 5 5 5 11' - 5"7' - 6" BREAKROOM 102 A130 01 WC 105JANITOR 104 03/ A60104/ A601 A130 03 A130 02 9" 9" 9" EX107 EX106 EX101B 101105 104103102EX101A2' - 0"6' - 8" 10' - 0" 6' - 0" 9 10 9 11 3 3 3 12 14 5' - 0"7' - 0" 5' - 0" 5' - 0" 4' - 0" 1 4 4 4 A. REFER TO A001-A002 FOR GENERAL NOTES, WALL TYPES, SYMBOLS AND TYPICAL CONSTRUCTION DETAILS. B. PROVIDE BULLNOSE CMU AT ALL EXPOSED CMU CORNERS. C. PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM WALLBOARD AT THE APPARATUS BAY AND ALL ROOMS DIRECTLY OFF OF IT. D. PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM WALLBOARD AT ALL WET WALLS IN KITCHENS, AND ALL WALLS AND CEILINGS IN BATHROOMS AND JANITOR CLOSETS. E. PROVIDE HIGH-IMPACT GYPSUM WALLBOARD AT ALL CORRIDORS, STAIRCASES AND THE LOBBY. F. PLAN KEYNOTES APPLY TO SHEETS A101, A102 AND A110. GENERAL PLAN NOTES A A.1 B B.1 C C.1 D 32 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 STAIR 11110' - 0"10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 153' - 6"19' - 8 1/4" 9' - 11" 24' - 11 3/8"170' - 0"04 A201 A110 04 01 A301 02 A301 03 A302 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" STORAGE UNITS 100 CONC P2 1 S14' - 0" 15' - 9" 4' - 0" 7' - 1 1/2" 111' - 9" 7' - 1 1/2"4' - 0" 25' - 9" 4' - 0" 63' - 6"4' - 0" 15' - 9" 4' - 0" 8' - 0" 109' - 11 7/8" 7' - 9 1/8" 4' - 0"15' - 9 1/4" 04 A306 111 EX111 01 A307 3 3 3 3 12 VESTIBULE 112 5' - 0" 7' - 0" 5' - 0"4' - 0"EX112 112 1 4 4 DANDR ID GE DRE W WHITEHI T AR-19400087 ARC TEC STATE OF No. DND I NAAAII R EG I STERE DNDI NAAI HI TARC TECDANDRID GE DREW WHITEREVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m CLIENT GSD DDW 08/17/2020 A101 FIRST FLOOR CONSTRUCTION PLAN 19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers 10505 N. College Avenue Brad Schoeff - Sr. Project Manager PH: 317-846-6611 Innovative Structural Solutions, P.A. 5279 Kyler Avenue, NE PH: 763-425-9960 Gooderum & Associates Engineering 874 Cheltenham Way PH: 317-506-8151 Indianapolis, IN 46280 Albertville, MN 55301 Avon, IN 46123 Extra Space Storage 9000 Keystone Crossing, Ste. 660 Jim Adams Indianapolis, IN 46240 PH: 317-663-8648 CIVIL ENGINEER STRUCTURAL ENGINEER MEP ENGINEER SCALE: 1/8" = 1'-0" 01 FIRST FLOOR CONSTRUCTION PLAN -AREA A PLAN KEYNOTES 2 LAUNDRY TUB - REFER TO PLUMBING DRAWINGS. 3 PREFINISHED METAL DOWNSPOUT. REFER TO CIVIL DRAWINGS FOR CONNECTION TO STORM DRAINAGE DETAILS. 4 CONCRETE FILLED 6" DIA STEEL BOLLARD - REFER TO DETAIL XX/AXXX. REFER TO CIVIL DRAWINGS FOR EXTERIOR BOLLARDS. COORDINATE WITH FOOTINGS. 5 ALUMINUM EXTERIOR STOREFRONT SYSTEM. 9 COMPUTER KIOSK, COORDINATE POWER/DATA CONNECTIONS WITH VENDOR AND REFERENCE MEP DRAWINGS. 10 TYPICAL 80", 8 PANEL ELECTRIC GREEN FEATURE WALL PANEL SYSTEM, W/ TWO MONITORS. 11 TYPICAL 10', 12 PANEL ELECTRIC GREEN FEATURE WALL PANEL SYSTEM, W/SIGNAGE ONLY 12 LOCATION OF HVAC SUPPLY/RETURN DUCTWORK, APPROX. 48"X48" PENETRATION IN FLOOR, ABOVE, COORDINATE WITH HVAC CONTRACTOR IN FIELD. 14 STORAGE UNIT PROVIDER TO SUPPLY WHITE UNIT PANEL TO COVER DRYWALL IN AREAS NOT OBSTRUCTED BY BUILT UNITS, TYPICAL THIS AREA. SCALE: 1/8" = 1'-0"02FIRST FLOOR CONSTRUCTION PLAN -AREA B #DESCRIPTION DATE 1 BID ADDEN. 001 10/13/2020 07/14/21