Loading...
HomeMy WebLinkAboutA104 - 100_BID AND PERMIT (08-27-20)RT: RL: XX' X ROOF TYPE APPROXIMATE ROOF HEIGHT 60 MIL MECHANICALLY FASTENED TPO MEMBRANE ROOFING SYSTEM OVER POLYISOCYANURATE INSULATION (R30 MIN.) OVER METAL DECK. RT1: TAPERED INSULATION CRICKETS 1/2":12" MIN. SLOPE. A. PROVIDE MANUFACTURERS STANDARD DETAILS WHERE MECHANICAL EQUIPMENT OCCURS, COORDINATE WITH ARCHITECTURE AND MEP. B. PROVIDE MANUFACTURERS STANDARD DETAILS AT ROOF BASE FLASHING, RIDGES, TAPERED INSULATION CRICKETS, ROOF EDGES, ETC. C. NOT ALL MEP EQUIPMENT AND PENETRATIONS ARE SHOWN. SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL ROOF PENETRATION REQUIREMENTS. D. COORDINATE ALL ROOFTOP OPENINGS WITH STRUCTURAL AND MECHANICAL DRAWINGS. ROOFTOP WALKWAY PAD BY ROOFING MEMBRANE MFR. GENERAL ROOF NOTES ROOF TYPES LEGEND A 1 A.1 B B.1 C C.1 D 2 3 4 5 6 7 8 9 10 11 12 13 14 15 01A20101A20203 A201 02A20102A20201 A301 04 A301 03 A301 01 A302 02 A302 1/4" / 1'-0" 1/4" / 1'-0" 1 1 1 3 3 2 2 4 5 3 1/4" / 1'-0" 1/4" / 1'-0" 3 1 2 RT: RL:VARIES RT1 A A.1 B B.1 C C.1 D 32 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 04 A201 01 A301 01 A302 02 A302 02 A301 03 A302 04 A306 1/4" / 1'-0" 1/4" / 1'-0" 01 A307 3 2 2 3 1/4" / 1'-0" 1/4" / 1'-0" 1 1 1 2 1 RT: RL:VARIES RT1 DANDR ID GE DRE W WHITEHI T AR-19400087 ARC TEC STATE OF No. DNDI NAAAII R EG I STERE DNDI NAAI HI TARC TECDANDRID GE DRE W WHITEREVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m CLIENT AUTHOR CHECKER 07/02/2015 A104 ROOF PLAN 19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers 10505 N. College Avenue Brad Schoeff -Sr. Project Manager PH: 317-846-6611 Innovative Structural Solutions, P.A. 5279 Kyler Avenue, NE PH: 763-425-9960 Gooderum & Associates Engineering 874 Cheltenham Way PH: 317-506-8151 Indianapolis, IN 46280 Albertville, MN 55301 Avon, IN 46123 Extra Space Storage 9000 Keystone Crossing, Ste. 660 Jim Adams Indianapolis, IN 46240 PH: 317-663-8648 CIVIL ENGINEER STRUCTURAL ENGINEER MEP ENGINEER ROOF PLAN KEYNOTES 1 PRE-MANUFACURED METAL COPING 2 EIFS CONTROL JOINT, TYPICAL. 3 ADDITIONAL 1/4" PER FOOT TAPERED INSULATION SHOWN CROSSHATCHED. 4 SAFETY LINE CABLE SYSTEM WITH POST ANCHORS - COORDINATE ANCHORING WITH STRUCTURAL DWGS. 5 ROOF HATCH AND ACCESS LADDER 6 SCALE: 1/8" = 1'-0" 01 ROOF PLAN -AREA A SCALE: 1/8" = 1'-0" 02 ROOF PLAN -AREA B #DESCRIPTION DATE 07/14/21