HomeMy WebLinkAboutGN010.2 Detail sheetEWP - DETAIL SHEET BRICK CANTILEVER DETAILSQUICK REFERENCE SPAN CHART Floor Spans for I-Joist Max Spans Recommended Spans 11 7/8" PRI 40 19.2 o. c.18' 2"18' 2" 16 o. c.19' 7"19' 12 o. c.21' 6"20' 6" 11 7/8" PRI 80 19.2 o. c.21' 4"20' 4" 16 o. c.22' 8"21' 4" 12 o. c.24' 11"22' 8" 14" PRI 60 19.2 o. c.22' 2"21' 16 o. c.23' 6"22' 12 o. c.25' 9"22' 8" 16" PRI 80 19.2 o. c.26' 11"23' 11' 16 o. c.28' 6"25' 12 o. c.31' 4"27' All spans are Max Spans based on(L/480) with up to 1" of deflection Recommended spans are at (L/480) with less than 1/2" of deflection Deflections listed represent live load only Not Valid for flat roofs, decks or floors that must carry walls for ceiling joist or rafter support. MULTI-PIECE BEAM General Notes for Multiple-Piece Beams Member Depth 3 1/2 – 51/4 Wide Multiple Piece Member 7 Wide Multiple Piece Member 91/4 –117/8 14 –18 1. Top and bottom rows of connectors should be 2 from edge. 2. Bolt holes are to be the same diameter as the bolt. Every bolt must extend through the full thickness of the member. Use washers under head and nut. Carriage bolts may be used, but the outermost portion of the head may not be drawn in beyond flush with the outside face of the member. 3. For three-piece members attached with nails or screws, specified attachment is from each side. Stagger fasteners from opposite sides by half the fastener spacing to avoid splitting. 4. To minimize rotation, 7" wide members should only be used when loads are applied to both sides, or completely across the top of the member. 5. 7" wide members, regardless of depth, must be attached using bolts or screws. 2 rows 1/2 bolts at 24 o.c. (pattern C) or 2 rows 1/4 x 6 SDSscrews at 24 o.c. (see note 3) 2 rows 16d nails at 12 o.c.(pattern A) 3 rows 16d nails at 12 o.c.(pattern B) Fastening Pattern Nails Bolts Screws1 A B C2 D E2,3 F3 2 rows 3 rows 2 rows 2 rows 2 rows 2 rows 16d common 16d common 1⁄2 bolts at 24 o.c.1⁄2 bolts 1⁄4 x 31⁄2 screws at 1⁄4 x 31⁄2 screws at at 12 o.c.at 12 o.c.staggered at 12 o.c. 24 o.c. staggered 12 o.c. Nails Bolts Screws A (Nails), D (Bolts) or F (Screws) = Two Rows 12" O.C. C (Bolts) or E (Screws) = Two Rows 24" O.C. B (Nails) = Three Rows 12" O.C. 24"12"12" 1. Screws are Simpson Strong-Tie SDS Series installed per manufacturer’s recommendations. 2. Stagger each row of fasteners by 12 . 3. When screws are used in attaching members to form a 7 thick beam: a) specified attachment is from each side (stagger screws from opposite sides by half the fastener spacing to avoid splitting), and b) screws must be 6 long, unless the center member is 31⁄2 thick. 4. Nails are only to be used for top load applications. o.c. o.c. o.c. o.c. Install these hangers upside down Blocking Panels Install single ply of IVI board 7’ back from end Set LVL to inside of framed wall and fill space with framing lumber O.C. O.C. O.C. O.C. O.C. O.C. Filler block to be used when side loading a double joist Two 10D nails every 12” O.C. use same pattern on second side starting 6” from first pair of nails on the first side FILLER BLOCK SIZES 9-1/2” PRI-40 11-7/8” PRI-40 11-7/8” PRI-80 14” PRI-60 16” PRI-80 2-1/8” x 6” 2-1/8” x 8” 3-1/8” x 8” 2-1/8” x 10” 3-1/8” x 12” 13 TOP MOUNT HANGER BEAM FACE MOUNT HANGER WEB STIFFENERS ARE REQUIRED IF THE SIDES OF THE HANGERS DO NOT LATERALLY SUPPORT THE TOP FLANGE OF THE I-JOIST 14 11 I-JOIST CANTILEVER DETAIL FOR BALCONIES CANTILEVER EXTENSION SUPPORTING UNIFORM FLOOR LOADS ONLY RIM BOARD, OR WOOD STRUCTURAL PANEL CAUTION: CANTILEVERS FORMED THIS WAY MUST BE CAREFULLYDETAILED TO PREVENT MOISTURE INTRUSION INTO THE STRUCTURE AND POTENTIAL DECAY OF UNTREATEDI-JOIST EXTENSIONS. 3-1/2” MIN. BEARING REQUIRED I-JOIST, OR APA RIM BOARD ATTACH I-JOISTSTO PLATE AT ALL SUPPORTS PER DETAIL 1. 4‘ MAXIMUM 12 FULL DEPTH BACKER BLOCK WITH 1/8” GAP BETWEEN BLOCK AND TOP FLANGE OFI-JOIST. SEE DETAIL7. NAIL WITH 2 ROWS OF 10D NAILS @ 6” O.C. AND CLINCH. I-JOIST, OR APA RIM BOARD 3-1/2” MIN. BEARING REQUIRED LUMBER OR WOOD STRUCTURALPANEL CLOSURE CANTILEVEREXTENSION SUPPORTING UNIFORMFLOOR LOADS ONLY 4‘ MAXIMUM 2 TIMES THE LENGTH OF CANTILEVER MIN. ATTACH I-JOISTS TO PLATE AT ALL SUPPORTS PER DETAIL 2 2 X 8 MIN. NAIL TO BACKER BLOCK AND JOIST WITH 2 ROWS OF 10D NAILS @ 6” O.C. AND CLINCH. (CANTILEVER NAILS MAY BE USED TO ATTACH BACKER BLOCK IF LENGTH OF NAIL IS SUFFICIENT TO ALLOW CLINCHING.) LUMBER CANTILEVER DETAIL FOR BALCONIES 10 APA RIM BOARD OR WOOD STRUCTURAL PANEL CLOSURE(23/32” MINIMUM THICKNESS) METHOD 1 SHEATHING REINFORCEMENT ONE SIDE METHOD 2SHEATHING REINFORCEMENT TWO SIDES 8D NAILS 3-1/2” MIN. BEARING REQUIRED NOTE: APA RATED SHEATHING 48/24 (MINIMUM THICKNESS 23/32”) REQUIRED ON SIDES OF JOIST. DEPTH SHALL MATCH THE FULL HEIGHT OF THE JOIST. NAIL WITH 8D NAILS AT 6” O.C., TOP AND BOTTOM FLANGE. INSTALL WITH FACE GRAIN HORIZONTAL.ATTACH I-JOIST TO PLATE AT ALL SUPPORTS PER DETAIL 2. STR E N G T H A X I S PRI BLOCKING PANEL USE NAILING PATTERN SHOWN FOR METHOD 1 WITH OPPOSITEFACE NAILING OFFSET BY 3” 2‘ - 0” MAXIMUM 4‘ - 0” MINIMUM STR E N G T H A X I S 9 DO NOT BEVEL- CUT JOIST BEYOND INSIDE FACE OF WALL. ATTACH I-JOISTPER 2. NOTE: BLOCKING REQUIRED AT BEARING FOR LATERAL SUPPORT, NOT SHOWN FOR CLARITY. 8 2X PLATE FLUSH WITH INSIDE FACEOF WALL OR BEAM NOTE: UNLESS HANGER SIDES LATERALLY SUPPORT THE TOP FLANGE, BEARING STIFFENERSSHALL BE USED. TOP MOUNTED HANGER INSTALLED PER MANUFACTURERSRECOMMENDATIONS 7 FILLER BLOCK TOP ORFACE-MOUNTEDHANGER DOUBLE I-JOIST HEADER NOTE: UNLESS HANGER SIDESLATERALLY SUPPORT THE TOPFLANGE, BEARING STIFFENERSSHALL BE USED. BACKER BLOCK REQUIRED(BOTH SIDES FOR FACE-MOUNTED HANGERS) BACKER BLOCK (USE IF HANGER EXCEEDS 250LBS.)BEFORE INSTALLING A BACKER BLOCK TO A DOUBLEI-JOIST, DRIVE 3 ADDITIONAL 10D NAILS THROUGH THE WEBS AND FILLER BLOCK WHERE THE BACKERBLOCK WILL FIT. CLINCH. INSTALL BACKER TIGHT TOTOP FLANGE. USE TWELVE 10D NAILS, CLINCHED WHENPOSSIBLE. MAXIMUM CAPACITY FOR HANGER FORTHIS DETAIL = 1280 LBS. BACKER BLOCKS (BLOCKS MUST BE LONG ENOUGH TOPERMIT REQUIRED NAILING WITHOUT SPLITTING) *MINIMUM GRADE FOR BACKER BLOCK MATERIAL SHALL BE UTILITY GRADE SPF (SOUTH) OR BETTER FOR SOLID SAWN LUMBER AND RATED SHEATHING GRADE FOR WOOD STRUCTURAL PANELS.** FOR FACE-MOUNT HANGERS USE NET JOIST DEPTH MINUS 3-1/4˝ FOR JOISTS WITH 1-1/2˝ THICK FLANGES. FOR 1-5/16˝ THICK FLANGESUSE NET DEPTH MINUS 2-7/8˝. FLANGEWIDTH 2-1/2˝3-1/2˝ MINIMUMDEPTH** 5-1/2˝7-1/4˝ MATERIAL THICKNESSREQUIRED* 1˝1-1/2˝ 2 APA RIM BOARD ONE 8D NAIL AT TOP ANDBOTTOM FLANGE ATTACH RIM BOARD TOTOP PLATE USING 8D BOXTOENAILS @ 6˝ O.C.ONE 8D FACENAIL AT EACHSIDE AT BEARING TO AVOID SPLITTING FLANGE START NAILS AT LEAST 1-1/2˝ FROM END OF I-JOIST. NAILS MAY BE DRIVEN AT AN ANGLE TO AVOID SPLITTING OF BEARING PLATE. TRANSFER LOAD FROMABOVE TO BEARING BELOW.MATCH BEARING AREA OF BLOCKS BELOW TO POST ABOVE. 4 6 8D NAILS AT 6˝ O.C. TO TOP PLATE PRI BLOCKING PANEL PER 1 BLOCKING REQUIRED OVER ALL INTERIOR SUPPORTS, UNDER LOAD BEARING WALLS, OR WHEN FLOOR JOIST ARE NOT CONTINUOUSOVER SUPPORT. WHEN JOIST ARE CONTINUOUS SQUASH BLOCKS MAY BE USED TO REPLACE PRI BLOCKING PER DETAIL 3. LOAD BEARING WALL ABOVE SHALL ALIGN VERTICALLYWITH THE WALL BELOW. OTHER CONDITIONS, SUCH ASOFFSET WALLS, ARE NOT COVERED BY THIS DETAIL. 1 PRI BLOCKING PANEL Attach I-JOISTTO TOP PLATE PER 2 8D NAILS @ 6˝ O.C.(WHEN USED FOR LATERALSHEAR TRANSFER, NAIL TO BEARING PLATE WITH SAMENAILING AS REQUIRED FOR DECKING) 3 PAIR OF SQUASH BLOCKS 2X LUMBER 3-1/2˝ WIDE 4000 7000 5-1/2˝ WIDE VERTICAL LOAD TRANSFERCAPACITY PER PAIR OF SQUASH BLOCKS (LB) PROVIDE LATERAL BRACING PER 1, OR 2 BLOCKING PANEL SQUASH BLOCK + 1/16˝FOR SQUASHBLOCKS 5 WALL SHEATHING,AS REQUIRED PROVIDE BACKEROR RIMBOARD FORSIDING ATTACHMENT UNLESS NAILABLE SHEATHING IS USED APA RIM BOARD MAY BE USED WITH I-JOISTS. BACKER IS NOT REQUIRED WHEN APA RIM BOARD IS USED. PRI PRI o.c. o.c. o.c. o.c. o.c.PRI PRI PRI PRI USE HANGERUSE HANGER PER LAYOUT PER LAYOUT IF SPECIFIEDIF SPECIFIED Engineered Wood Products