Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
GN010.4 Engr stamp
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). June 25,2021 Liu, Xuegang Pages or sheets covered by this seal: I46729275 thru I46729307 My license renewal date for the state of Indiana is July 31, 2022. j21103756 79 Sunrise IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use,the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss GE01 Truss Type Common Structural Gable Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729275 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:22 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-cqqw4_l5Z25kIHw5i8RXT1H0khmu_koDasOBI?z33nl Scale = 1:45.8 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 10 8 6 19 20 9 7 4x6 3x8 6x8 6x8 3-4-03-4-0 7-3-83-11-8 11-3-03-11-8 14-7-03-4-0 -0-10-8 0-10-8 7-3-8 7-3-8 14-7-0 7-3-8 15-5-8 0-10-8 1-5-47-6-31-5-410.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [4:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.83 0.10 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 0.00 (loc) 8 8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 203 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-10,4-6: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 3-7-8 except (jt=length) 9=0-3-8, 7=0-3-8. (lb) - Max Horz 10=144(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 10, 6 Max Grav All reactions 250 lb or less at joint(s) 9, 7 except 10=555(LC 1), 6=555(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-493/117, 3-4=-493/116, 2-10=-524/119, 4-6=-524/119 BOT CHORD 9-10=-132/298, 8-9=-132/298 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 7-3-8, Exterior(2R) 7-3-8 to 10-3-8, Interior(1) 10-3-8 to 15-5-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 6. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss GE02 Truss Type Common Supported Gable Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729276 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:24 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-YDxhVgmL5fLRYa4UqZU?YSNYPVSzScpW1AtHMuz33nj Scale = 1:60.6 Sheet FrontFull Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 29 28 27 26 25 24 23 22 21 20 19 18 17 16 4x6 3x6 24-6-024-6-0 -0-10-8 0-10-8 12-3-0 12-3-0 24-6-0 12-3-0 25-4-8 0-10-8 1-3-89-5-81-3-88.00 12 Plate Offsets (X,Y)-- [24:0-2-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.12 0.07 0.19 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 15 15 16 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 376 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-22 REACTIONS.All bearings 24-6-0. (lb) - Max Horz 29=163(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 29, 16, 23, 25, 26, 27, 28, 21, 20, 19, 18, 17 Max Grav All reactions 250 lb or less at joint(s) 29, 16, 22, 23, 25, 26, 27, 28, 21, 20, 19, 18, 17 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=25ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -0-10-8 to 2-3-0, Exterior(2N) 2-3-0 to 12-3-0, Corner(3R) 12-3-0 to 15-3-0, Exterior(2N) 15-3-0 to 25-4-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 29, 16, 23, 25, 26, 27, 28, 21, 20, 19, 18, 17. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss GE03 Truss Type Common Supported Gable Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729277 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:25 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-0PV3i?nzszTI9kfgOG?E5fvj3vnDB33gGqdrvKz33ni Scale = 1:60.6 Sheet BackFull Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 28 27 26 25 24 23 22 21 20 19 18 17 16 15 29 4x6 3x6 24-6-024-6-0 -0-10-8 0-10-8 12-3-0 12-3-0 24-6-0 12-3-0 1-3-89-5-81-3-88.00 12 Plate Offsets (X,Y)-- [23:0-2-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.12 0.06 0.19 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 1 1 15 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 375 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-21 REACTIONS.All bearings 24-6-0. (lb) - Max Horz 28=160(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 28, 15, 22, 24, 25, 26, 27, 20, 19, 18, 17, 16 Max Grav All reactions 250 lb or less at joint(s) 28, 15, 21, 22, 24, 25, 26, 27, 20, 19, 18, 17, 16 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=25ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -0-10-8 to 2-3-0, Exterior(2N) 2-3-0 to 12-3-0, Corner(3R) 12-3-0 to 15-3-0, Exterior(2N) 15-3-0 to 24-4-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 28, 15, 22, 24, 25, 26, 27, 20, 19, 18, 17, 16. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss GE04 Truss Type Common Supported Gable Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729278 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:27 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-yodp7hpEOaj0P2p3Vh1iA4?3GiUmf_jyj86yzDz33ng Scale = 1:46.1 Sheet FrontFull Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 25 24 23 22 21 20 19 18 17 16 15 14 26 27 4x6 3x6 22-7-022-7-0 -0-10-8 0-10-8 11-3-8 11-3-8 22-7-0 11-3-8 23-5-8 0-10-8 0-11-66-7-20-11-66.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.08 0.06 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 12 13 14 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 256 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 22-7-0. (lb) - Max Horz 25=-97(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 25, 14, 20, 21, 23, 24, 18, 17, 16, 15 Max Grav All reactions 250 lb or less at joint(s) 25, 14, 19, 20, 21, 23, 24, 18, 17, 16, 15 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -0-10-8 to 2-1-8, Exterior(2N) 2-1-8 to 11-3-8, Corner(3R) 11-3-8 to 14-3-8, Exterior(2N) 14-3-8 to 23-5-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 25, 14, 20, 21, 23, 24, 18, 17, 16, 15. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss GE05 Truss Type Common Supported Gable Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729279 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:28 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-Q_BBK1qs9urt0CNF3OYxiIXFI6qSOSA6yorVVfz33nf Scale = 1:26.4 Sheet FrontFull Sheathing1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 4x6 12-7-012-7-0 -0-10-8 0-10-8 6-3-8 6-3-8 12-7-0 6-3-8 13-5-8 0-10-8 0-11-64-1-20-11-66.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.06 0.03 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 9 9 10 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 107 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-7-0. (lb) - Max Horz 16=-64(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 16, 10, 14, 15, 12, 11 Max Grav All reactions 250 lb or less at joint(s) 16, 10, 13, 14, 15, 12, 11 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -0-10-8 to 2-3-8, Exterior(2N) 2-3-8 to 6-3-8, Corner(3R) 6-3-8 to 9-3-8, Exterior(2N) 9-3-8 to 13-5-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 10, 14, 15, 12, 11. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss GE06 Truss Type Common Supported Gable Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729280 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:30 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-NNIyljr6hV5bGVXeApaPojdZUwWnsJfPP5KcaYz33nd Scale = 1:53.7 Sheet FrontFull Sheathing1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 36 37 3x6 4x6 3x6 3x6 29-4-029-4-0 -0-10-8 0-10-8 14-8-0 14-8-0 29-4-0 14-8-0 30-2-8 0-10-8 0-11-68-3-60-11-66.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.08 0.04 0.23 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 18 19 20 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 393 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 29-4-0. (lb) - Max Horz 35=125(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 35, 20, 29, 30, 31, 32, 33, 34, 26, 25, 24, 23, 22, 21 Max Grav All reactions 250 lb or less at joint(s) 35, 20, 27, 29, 30, 31, 32, 33, 34, 26, 25, 24, 23, 22, 21 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=29ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -0-10-8 to 2-1-8, Exterior(2N) 2-1-8 to 14-8-0, Corner(3R) 14-8-0 to 17-8-0, Exterior(2N) 17-8-0 to 30-2-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 35, 20, 29, 30, 31, 32, 33, 34, 26, 25, 24, 23, 22, 21. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss GE07 Truss Type Monopitch Supported Gable Qty 2 Ply 1 79 Sunrise Job Reference (optional) I46729281 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:31 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-rZsKz3skSpDSuf6qkX6eKw9kVKrObpXYel496_z33nc Scale = 1:12.6 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 2x4 2x4 2x4 -0-10-8 0-10-8 3-0-0 3-0-0 0-5-61-11-66.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.13 0.08 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=3-0-0, 2=3-0-0 Max Horz 2=47(LC 11) Max Uplift 2=-19(LC 12) Max Grav 4=108(LC 1), 2=176(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -0-10-8 to 2-1-8, Exterior(2N) 2-1-8 to 2-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss GE08 Truss Type Flat Supported Gable Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729282 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:31 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-rZsKz3skSpDSuf6qkX6eKw9jAKr6bpXYel496_z33nc Scale: 1.5"=1' Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 4 3 2x4 2x4 2x4 2x4 3-10-03-10-0 3-10-0 3-10-0 1-0-11LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.15 0.10 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD 2-0-0 oc purlins: 1-2, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=3-10-0, 3=3-10-0 Max Horz 4=19(LC 9) Max Uplift 4=-12(LC 8), 3=-12(LC 9) Max Grav 4=145(LC 1), 3=145(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 3. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss J01 Truss Type MONO TRUSS Qty 5 Ply 1 79 Sunrise Job Reference (optional) I46729283 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:32 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-JlQiAPtMD6LJVph0IEdtt8iuajAuKGGitPpifQz33nb Scale = 1:17.1 1 2 3 5 4 6 7 2x4 2x4 3x4 3x4 3-10-03-10-0 -0-10-8 0-10-8 3-10-0 3-10-0 1-2-142-10-15.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.17 0.13 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=0-3-8 Max Horz 5=71(LC 9) Max Uplift 5=-17(LC 12), 4=-10(LC 9) Max Grav 5=213(LC 1), 4=135(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 3-8-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss M01 Truss Type MONO TRUSS Qty 8 Ply 1 79 Sunrise Job Reference (optional) I46729284 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:33 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-nx_4Okt?zQTA7zGDsy86PLF4V7Xa3jvr53ZGBtz33na Scale = 1:12.6 1 2 3 4 5 6 7 2x4 2x4 4x8 3-0-03-0-0 -0-10-8 0-10-8 3-0-0 3-0-0 0-5-61-11-61-2-01-11-66.00 12 Plate Offsets (X,Y)-- [2:0-0-1,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.09 0.03 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 2 2-4 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=37(LC 9) Max Uplift 2=-21(LC 12) Max Grav 2=179(LC 1), 6=66(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 2-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss T01 Truss Type Common Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729285 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:34 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-F8YTb4udkkb1l7rPPffLyZn3ZXnKo9t_KjIpjJz33nZ Scale: 1/4"=1' 1 2 3 4 5 8 7 6 9 10 4x6 3x4 3x4 3x8 6x8 6x8 7-3-87-3-8 14-7-07-3-8 -0-10-8 0-10-8 7-3-8 7-3-8 14-7-0 7-3-8 15-5-8 0-10-8 1-5-47-6-31-5-410.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [4:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.84 0.38 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.05 -0.11 0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 60 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-8,4-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 6=0-3-8 Max Horz 8=-144(LC 10) Max Uplift 8=-12(LC 12), 6=-12(LC 12) Max Grav 8=633(LC 1), 6=633(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-556/76, 3-4=-556/76, 2-8=-569/90, 4-6=-569/90 BOT CHORD 7-8=-115/320 WEBS 3-7=0/282 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 7-3-8, Exterior(2R) 7-3-8 to 10-3-8, Interior(1) 10-3-8 to 15-5-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss T02 Truss Type Common Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729286 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:34 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-F8YTb4udkkb1l7rPPffLyZn3eXnKo9v_KjIpjJz33nZ Scale: 1/4"=1' 1 2 3 4 7 6 5 8 9 6x8 4x6 3x4 3x4 3x8 6x8 7-3-87-3-8 14-7-07-3-8 7-3-8 7-3-8 14-7-0 7-3-8 15-5-8 0-10-8 1-5-47-6-31-5-410.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-10], [3:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.84 0.38 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.05 -0.11 0.00 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 59 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-7,3-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=0-3-8, 5=0-3-8 Max Horz 7=-140(LC 10) Max Uplift 5=-11(LC 12) Max Grav 7=569(LC 1), 5=635(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-551/71, 2-3=-559/76, 1-7=-506/62, 3-5=-571/90 BOT CHORD 6-7=-89/258 WEBS 2-6=0/278 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 7-3-8, Exterior(2R) 7-3-8 to 10-3-8, Interior(1) 10-3-8 to 15-5-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss T03 Truss Type Roof Special Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729287 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:36 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-BWgD0mwtGLsk_Q?oX4hp1_tWpLWOGvmHo1nwoBz33nX Scale = 1:62.1 1 2 3 4 5 6 7 8 9 10 11 12 22 21 20 19 18 17 16 15 14 13 5x8 4x6 4x6 4x6 4x6 6x6 4x6 4x6 4x6 3x6 3x8 2x4 3x12 3x4 3x4 3x4 3x4 3x4 3x4 3x4 3x6 2-9-4 2-9-4 4-6-6 1-9-2 6-2-14 1-8-8 7-10-8 1-7-10 9-5-4 1-6-12 10-10-14 1-5-10 12-3-5 1-4-8 13-6-9 1-3-4 14-8-8 1-1-15 -0-10-8 0-10-8 0-11-15 0-11-15 2-9-4 1-9-5 4-6-6 1-9-2 6-2-14 1-8-8 7-10-8 1-7-10 9-5-4 1-6-12 10-10-14 1-5-10 12-3-5 1-4-8 13-6-9 1-3-4 14-8-8 1-1-15 1-0-111-3-31-9-62-5-53-3-04-2-35-2-146-5-07-8-79-1-210-7-02.48 123.49 12 4.54 12 5.65 12 6.84 12 8.15 12 9.62 12 11.23 12 13.13 12 15.39 12 Plate Offsets (X,Y)-- [21:0-4-14,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.41 0.22 0.70 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.04 -0.07 0.01 (loc) 18 18 13 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 114 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 12-13: 2x4 SPF No.2, 2-22: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-4-14 oc bracing. WEBS 1 Row at midpt 12-13, 11-13 REACTIONS. (size)13=Mechanical, 22=0-3-8 Max Horz 22=275(LC 9) Max Uplift 13=-36(LC 9) Max Grav 13=589(LC 17), 22=640(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-818/54, 3-4=-837/48, 4-5=-889/61, 5-6=-783/63, 6-7=-668/69, 7-8=-548/79, 8-9=-432/94, 9-10=-335/118, 2-22=-598/99 BOT CHORD 21-22=-398/343, 20-21=-199/814, 19-20=-145/812, 18-19=-122/683, 17-18=-110/530, 16-17=-104/384, 15-16=-98/261 WEBS 6-18=-313/48, 7-18=-24/310, 7-17=-391/65, 8-17=-43/402, 8-16=-455/86, 9-16=-68/457, 9-15=-492/117, 10-15=-84/518, 10-14=-516/139, 11-14=-246/523, 11-13=-512/162, 2-21=-46/689 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-10-8 to 2-9-4, Interior(1) 2-9-4 to 14-6-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss T04 Truss Type Common Qty 6 Ply 1 79 Sunrise Job Reference (optional) I46729288 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:37 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-fjEbD6wV1f_bcaa_5nC2aBPgQklq_OwR0hXTKez33nW Scale = 1:59.0 1 2 3 4 5 6 7 12 11 10 9 8 13 14 15 16 4x6 3x6 3x4 3x6 3x4 3x6 3x6 3x8 3x8 3x6 8-2-138-2-13 16-3-38-0-5 24-6-08-2-13 -0-10-8 0-10-8 6-2-12 6-2-12 12-3-0 6-0-4 18-3-4 6-0-4 24-6-0 6-2-12 25-4-8 0-10-8 1-3-89-5-81-3-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.48 0.65 0.58 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.16 -0.23 0.04 (loc) 9-11 9-11 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 103 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-12,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-5 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-12, 5-8 REACTIONS. (size)12=0-3-8, 8=0-3-8 Max Horz 12=164(LC 11) Max Uplift 12=-5(LC 12), 8=-5(LC 12) Max Grav 12=1135(LC 17), 8=1135(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-368/98, 3-4=-1219/105, 4-5=-1219/105, 5-6=-368/98, 2-12=-377/94, 6-8=-377/94 BOT CHORD 11-12=0/1083, 9-11=0/773, 8-9=0/997 WEBS 4-9=-20/575, 4-11=-20/575, 3-12=-1043/0, 5-8=-1043/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 12-3-0, Exterior(2R) 12-3-0 to 15-3-0, Interior(1) 15-3-0 to 25-4-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 8. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss T05 Truss Type Common Qty 6 Ply 1 79 Sunrise Job Reference (optional) I46729289 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:38 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-8vnzRSx7oy6SDk8AeVkH6PyrB841jrlaFLG1s4z33nV Scale = 1:59.0 1 2 3 4 5 6 11 10 9 8 7 12 13 14 15 4x6 3x6 3x6 3x4 3x6 3x4 3x6 3x6 3x8 3x8 8-2-138-2-13 16-3-38-0-5 24-6-08-2-13 -0-10-8 0-10-8 6-2-12 6-2-12 12-3-0 6-0-4 18-3-4 6-0-4 24-6-0 6-2-12 1-3-89-5-81-3-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.48 0.66 0.61 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.16 -0.23 0.04 (loc) 8-10 8-10 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 101 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-11,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-11, 5-7 REACTIONS. (size)11=0-3-8, 7=Mechanical Max Horz 11=161(LC 11) Max Uplift 11=-5(LC 12) Max Grav 11=1136(LC 17), 7=1080(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-368/98, 3-4=-1220/105, 4-5=-1225/105, 5-6=-318/73, 2-11=-377/94, 6-7=-286/54 BOT CHORD 10-11=0/1078, 8-10=0/768, 7-8=0/998 WEBS 4-8=-20/583, 5-8=-258/130, 4-10=-20/575, 3-11=-1045/0, 5-7=-1083/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 12-3-0, Exterior(2R) 12-3-0 to 15-3-0, Interior(1) 15-3-0 to 24-4-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss T06 Truss Type Roof Special Qty 2 Ply 1 79 Sunrise Job Reference (optional) I46729290 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:39 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-c5LMeoylZGEJrujNCCFWfcU0vYPlSEPjU?0aOWz33nU Scale = 1:59.0 1 2 3 4 5 6 7 14 13 12 11 10 9 8 15 16 4x6 5x6 2x4 2x4 8x10 3x12 3x12 3x8 2x4 3x8 3x4 4x6 6x6 6-2-126-2-12 14-1-07-10-4 19-1-05-0-0 24-6-05-5-0 -0-10-8 0-10-8 6-2-12 6-2-12 12-3-0 6-0-4 14-1-0 1-10-0 19-1-0 5-0-0 24-6-0 5-5-0 1-3-89-5-81-3-82-0-08.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [7:Edge,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.48 0.75 0.84 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.15 -0.35 0.30 (loc) 10-11 12-13 8 l/defl >999 >836 n/a L/d 240 180 n/a PLATES MT20 Weight: 118 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-12: 2x3 SPF No.2, 6-9: 2x6 SP 2400F 2.0E WEBS 2x3 SPF No.2 *Except* 2-14,7-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 9-10. WEBS 1 Row at midpt 3-12 REACTIONS. (size)14=0-3-8, 8=Mechanical Max Horz 14=161(LC 11) Max Uplift 14=-5(LC 12) Max Grav 14=1031(LC 1), 8=967(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1194/25, 3-4=-1004/70, 4-5=-1172/109, 5-6=-1268/60, 6-7=-1177/26, 2-14=-979/44, 7-8=-938/21 BOT CHORD 12-13=0/914, 11-12=0/652, 10-11=0/1647 WEBS 3-12=-1051/0, 3-11=0/761, 4-11=-40/928, 6-11=-743/50, 2-13=0/778, 7-9=0/816 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 12-3-0, Exterior(2R) 12-3-0 to 15-3-0, Interior(1) 15-3-0 to 24-4-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss T07 Truss Type Common Qty 7 Ply 1 79 Sunrise Job Reference (optional) I46729291 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:40 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-4Ivks8zOKaMAT2IZmwmlCq1C6ymZBpjtifl8xzz33nT Scale = 1:42.0 1 2 3 4 5 6 7 8 9 10 11 12 4x10 4x6 4x6 4x6 5x12 2x4 2x4 4x10 4x6 4x6 11-3-811-3-8 22-7-011-3-8 5-9-0 5-9-0 11-3-8 5-6-8 16-10-0 5-6-8 22-7-0 5-9-0 23-5-8 0-10-8 0-11-66-7-20-11-66.00 12 Plate Offsets (X,Y)-- [1:0-3-8,Edge], [7:0-7-7,Edge], [9:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.39 0.65 0.32 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.25 -0.51 0.03 (loc) 1-9 1-9 7 l/defl >999 >534 n/a L/d 240 180 n/a PLATES MT20 Weight: 83 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 3-3-10, Right 2x6 SPF No.2 3-3-10 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=Mechanical, 7=0-3-8 Max Horz 1=81(LC 11) Max Uplift 7=-4(LC 12) Max Grav 1=902(LC 1), 7=957(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1353/119, 3-4=-1045/86, 4-5=-1045/84, 5-7=-1348/115 BOT CHORD 1-9=-48/1092, 7-9=-39/1088 WEBS 4-9=0/575, 5-9=-295/125, 3-9=-299/126 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 11-3-8, Exterior(2R) 11-3-8 to 14-3-8, Interior(1) 14-3-8 to 23-5-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss T08 Truss Type Common Qty 3 Ply 1 79 Sunrise Job Reference (optional) I46729292 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:41 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-YUT63U_05tU14CtlKdH_k1aNsM6qwG10xJVhTPz33nS Scale = 1:42.5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 4x6 4x10 4x6 4x6 5x12 2x4 2x4 4x10 4x6 4x6 11-3-811-3-8 22-7-011-3-8 -0-10-8 0-10-8 5-9-0 5-9-0 11-3-8 5-6-8 16-10-0 5-6-8 22-7-0 5-9-0 23-5-8 0-10-8 0-11-66-7-20-11-66.00 12 Plate Offsets (X,Y)-- [2:0-7-7,Edge], [8:0-7-7,Edge], [10:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.39 0.65 0.32 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.24 -0.50 0.03 (loc) 8-10 8-10 8 l/defl >999 >542 n/a L/d 240 180 n/a PLATES MT20 Weight: 84 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 3-3-10, Right 2x6 SPF No.2 3-3-10 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 8=0-3-8 Max Horz 2=-79(LC 10) Max Uplift 2=-3(LC 12), 8=-3(LC 12) Max Grav 2=956(LC 1), 8=956(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1346/115, 4-5=-1043/84, 5-6=-1043/84, 6-8=-1346/115 BOT CHORD 2-10=-47/1086, 8-10=-39/1086 WEBS 5-10=0/574, 6-10=-295/125, 4-10=-295/125 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 11-3-8, Exterior(2R) 11-3-8 to 14-3-8, Interior(1) 14-3-8 to 23-5-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss T10 Truss Type Common Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729293 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:42 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-0g1UGp_esBcuiLSxtLoDHF6ZmlXnfmsAAzEE?rz33nR Scale = 1:26.8 1 2 3 4 5 6 7 8 9 10 4x6 3x8 4x6 4x6 3x8 4x6 4x6 2x4 6-3-86-3-8 12-7-06-3-8 -0-10-8 0-10-8 6-3-8 6-3-8 12-7-0 6-3-8 13-5-8 0-10-8 0-11-64-1-20-11-66.00 12 Plate Offsets (X,Y)-- [2:0-6-3,0-0-3], [6:0-6-3,0-0-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.38 0.35 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.07 0.01 (loc) 6-8 6-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 49 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 3-7-4, Right 2x6 SPF No.2 3-7-4 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=46(LC 11) Max Uplift 2=-10(LC 12), 6=-10(LC 12) Max Grav 2=556(LC 1), 6=556(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-619/120, 4-6=-618/120 BOT CHORD 2-8=-23/460, 6-8=-23/460 WEBS 4-8=0/285 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 6-3-8, Exterior(2R) 6-3-8 to 9-3-8 , Interior(1) 9-3-8 to 13-5-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss T11 Truss Type Common Qty 5 Ply 1 79 Sunrise Job Reference (optional) I46729294 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:43 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-UtbsU9?GdVklKV18R2JSpSfg79lCO6_JPd_oXHz33nQ Scale = 1:52.8 12 3 4 5 6 7 8 9 10 11 14 13 12 15 16 17 18 19 20 3x6 4x8 3x6 3x12 4x6 4x6 3x6 3x4 2x4 4x6 2x4 3x12 4x6 4x6 9-11-129-11-12 19-6-109-6-14 29-4-09-9-6 -0-10-8 0-10-8 7-5-4 7-5-4 14-8-0 7-2-12 21-10-12 7-2-12 29-4-0 7-5-4 30-2-8 0-10-8 0-11-68-3-60-11-66.00 12 Plate Offsets (X,Y)-- [2:0-7-7,Edge], [10:0-7-7,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.60 0.85 0.55 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.25 -0.44 0.02 (loc) 12-14 2-14 10 l/defl >927 >269 n/a L/d 240 180 n/a PLATES MT20 Weight: 111 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 4-3-1, Right 2x6 SPF No.2 4-3-1 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-14 REACTIONS. (size)2=0-3-8, 14=0-3-8, 10=0-3-8 Max Horz 2=-107(LC 10) Max Uplift 2=-41(LC 12), 10=-20(LC 12) Max Grav 2=490(LC 23), 14=1314(LC 17), 10=913(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-424/112, 6-8=-993/112, 8-10=-1169/78 BOT CHORD 2-14=-28/310, 12-14=0/412, 10-12=-1/950 WEBS 4-14=-444/122, 6-14=-694/0, 6-12=0/816, 8-12=-390/123 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=29ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 14-8-0, Exterior(2R) 14-8-0 to 17-8-0, Interior(1) 17-8-0 to 30-2-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss T12 Truss Type Common Qty 8 Ply 1 79 Sunrise Job Reference (optional) I46729295 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:44 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-y39FhV0uOoscxfcK?lrhMgCnZZ267evTdHjL4kz33nP Scale = 1:51.3 1 2 3 4 5 6 7 8 910 13 12 11 14 15 16 17 18 19 3x6 4x8 3x6 5x12 5x6 5x6 3x6 3x4 2x4 3x4 2x4 4x10 4x6 4x6 9-9-09-9-0 19-3-89-6-8 29-0-89-9-0 7-3-8 7-3-8 14-4-8 7-1-0 21-7-4 7-2-12 29-0-8 7-5-4 29-11-0 0-10-8 1-1-28-3-60-11-66.00 12 Plate Offsets (X,Y)-- [9:0-7-7,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.87 1.00 0.25 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.31 -0.46 0.07 (loc) 11-13 11-13 9 l/defl >999 >760 n/a L/d 240 180 n/a PLATES MT20 Weight: 115 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-4: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x8 SP 2400F 2.0E 4-2-13, Right 2x6 SPF No.2 4-3-1 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS. (size)1=Mechanical, 9=0-3-8 Max Horz 1=109(LC 11) Max Grav 1=1288(LC 17), 9=1336(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1960/64, 3-5=-1767/95, 5-7=-1815/92, 7-9=-2006/57 BOT CHORD 1-13=0/1677, 11-13=0/1213, 9-11=0/1660 WEBS 3-13=-315/127, 5-13=0/691, 5-11=0/740, 7-11=-342/127 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=29ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 14-4-8, Exterior(2R) 14-4-8 to 17-4-8, Interior(1) 17-4-8 to 29-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss T13 Truss Type Half Hip Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729296 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:45 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-QFjdvr1W96_TZpBWZTMwvtk7ZzdVs8gcsxTucAz33nO Scale = 1:15.2 1 2 3 4 7 6 5 8 4x6 2x4 3x4 2x4 3x4 3x4 1-11-01-11-0 3-10-01-11-0 -0-10-8 0-10-8 2-11-6 2-11-6 3-10-0 0-10-10 1-2-142-5-105.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.09 0.03 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 6 6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=Mechanical, 7=0-3-8 Max Horz 7=63(LC 9) Max Uplift 5=-14(LC 9), 7=-17(LC 12) Max Grav 5=135(LC 1), 7=213(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 2-11-6, Exterior(2E) 2-11-6 to 3-8-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 7. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss T14 Truss Type Half Hip Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729297 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:46 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-vSG?6B18wQ6KBzmj6At9R5HI6NzIbbol5bCS8cz33nN Scale = 1:11.4 1 2 3 4 7 6 5 4x8 2x4 3x4 2x4 3x4 3x4 1-1-151-1-15 3-10-02-8-1 -0-10-8 0-10-8 1-1-15 1-1-15 3-10-0 2-8-1 1-2-141-8-115.00 12 Plate Offsets (X,Y)-- [3:0-4-0,0-1-13] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.10 0.05 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=Mechanical, 7=0-3-8 Max Horz 7=42(LC 9) Max Uplift 5=-17(LC 9), 7=-19(LC 12) Max Grav 5=135(LC 1), 7=213(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-10-8 to 3-8-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 7. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss T15 Truss Type Flat Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729298 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:46 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-vSG?6B18wQ6KBzmj6At9R5HGLNx6bb8l5bCS8cz33nN Scale = 1:8.612 4 3 2x4 3x4 2x4 3x4 3-10-03-10-0 3-10-0 3-10-0 1-2-2LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.21 0.13 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 0.00 (loc) 3-4 3-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD 2-0-0 oc purlins: 1-2, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=0-3-8, 3=Mechanical Max Horz 4=22(LC 11) Max Uplift 4=-13(LC 8), 3=-13(LC 9) Max Grav 4=145(LC 1), 3=145(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss TG01 Truss Type Common Girder Qty 1 Ply 2 79 Sunrise Job Reference (optional) I46729299 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:48 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-rqOlXt3PR1M2QGv5EbvdWWMTiAYP3Nx2YvhZDVz33nL Scale = 1:26.1 1 2 3 4 5 6789 10 11 4x8 3x4 3x4 4x6 4x8 3x4 3x4 3x12 Special Special Special Special Special Special 6-3-86-3-8 12-7-06-3-8 6-3-8 6-3-8 12-7-0 6-3-8 0-11-64-1-20-11-66.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.80 0.46 0.56 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.06 -0.13 0.01 (loc) 1-6 1-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 111 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x3 SPF No.2 SLIDER Left 2x4 SPF-S Stud 3-6-6, Right 2x4 SPF-S Stud 3-6-6 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 5=0-3-8 Max Horz 1=-48(LC 25) Max Grav 1=3480(LC 1), 5=2825(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-3789/0, 3-5=-3794/0 BOT CHORD 1-6=0/3214, 5-6=0/3214 WEBS 3-6=0/3278 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x3 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 887 lb down at 0-6-12, 882 lb down at 2-6-12, 882 lb down at 4-6-12, 882 lb down at 6-6-12, and 882 lb down at 8-6-12, and 882 lb down at 10-6-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 1-5=-20 Concentrated Loads (lb) Vert: 6=-882(B) 7=-887(B) 8=-882(B) 9=-882(B) 10=-882(B) 11=-882(B)June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss TG02 Truss Type Common Girder Qty 1 Ply 2 79 Sunrise Job Reference (optional) I46729300 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:49 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-J0y8kD41CLUu2QUInJQs3jvfyasWoopCnZR6lxz33nK Scale: 1/4"=1' 1 2 3 6 5 4789101112 5x6 4x6 5x6 5x10 MT18HS 5x10 MT18HS8x8 Special Special Special Special Special Special Special 7-3-87-3-8 14-7-07-3-8 7-3-8 7-3-8 14-7-0 7-3-8 1-5-47-6-31-5-410.00 12 Plate Offsets (X,Y)-- [1:0-2-12,0-1-8], [3:0-2-12,0-1-8], [4:Edge,0-3-8], [5:0-4-0,0-4-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.77 0.60 0.65 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.11 -0.19 0.00 (loc) 4-5 4-5 4 l/defl >999 >890 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 150 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x3 SPF No.2 *Except* 1-6,3-4: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 4=0-3-8 Max Horz 6=-128(LC 25) Max Grav 6=3878(LC 1), 4=4092(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3343/0, 2-3=-3343/0, 1-6=-2537/0, 3-4=-2518/0 BOT CHORD 5-6=0/752, 4-5=0/796 WEBS 2-5=0/3791, 1-5=0/1863, 3-5=0/1736 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x3 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 947 lb down at 1-3-12, 947 lb down at 3-3-12, 1042 lb down at 5-3-12, 1042 lb down at 7-3-12, 1042 lb down at 9-3-12, and 1042 lb down at 11-3-12, and 1042 lb down at 13-3-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-6=-20 Continued on page 2 June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss TG02 Truss Type Common Girder Qty 1 Ply 2 79 Sunrise Job Reference (optional) I46729300 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:49 2021 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-J0y8kD41CLUu2QUInJQs3jvfyasWoopCnZR6lxz33nK LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 5=-947(B) 7=-947(B) 8=-947(B) 9=-947(B) 10=-947(B) 11=-947(B) 12=-947(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss TG03 Truss Type Roof Special Girder Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729301 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:51 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-FP4u9u5HkylcHkegvkTK88_27ObMGheVEtwDpqz33nI Scale = 1:65.5 Sheet FrontFull Sheathing1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 22 21 20 19 18 17 16 15 14 1330313233 5x8 5x6 3x4 8x8 3x12 3x4 3x4 3x4 3x4 3x6 2x4 2x4 3x4 3x4 2x4 2x4 2x4 2x4 Special Special Special Special Special Special Special Special 2-9-42-9-4 4-6-61-9-2 6-2-141-8-8 7-10-81-7-10 9-5-41-6-12 10-10-141-5-10 12-3-51-4-8 13-6-91-3-4 14-8-81-1-15 -0-10-8 0-10-8 0-11-15 0-11-15 2-9-4 1-9-5 4-6-6 1-9-2 6-2-14 1-8-8 7-10-8 1-7-10 9-5-4 1-6-12 10-10-14 1-5-10 12-3-5 1-4-8 13-6-9 1-3-4 14-8-8 1-1-15 1-0-111-3-31-9-62-5-53-3-04-2-35-2-146-5-07-8-79-1-210-7-02.48 123.49 12 4.54 12 5.65 12 6.84 12 8.15 12 9.62 12 11.23 12 13.13 12 15.39 12 Plate Offsets (X,Y)-- [16:0-2-8,0-2-0], [21:0-5-13,0-1-8], [22:0-3-0,0-2-0], [25:0-1-12,0-1-8], [25:0-1-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.53 0.38 0.76 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.08 -0.12 0.01 (loc) 18 18 13 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 263 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x3 SPF No.2 *Except* 12-13: 2x4 SPF No.2, 2-22: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 12-13, 10-14, 11-13 REACTIONS. (size)13=Mechanical, 22=0-3-8 Max Horz 22=273(LC 5) Max Uplift 13=-407(LC 5), 22=-195(LC 8) Max Grav 13=1091(LC 1), 22=1107(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1401/257, 3-4=-1495/284, 4-5=-1589/336, 5-6=-1371/335, 6-7=-1112/301, 7-8=-847/252, 8-9=-613/211, 9-10=-449/180, 10-11=-275/148, 2-22=-892/176 BOT CHORD 21-22=-270/339, 20-21=-324/1457, 19-20=-320/1459, 18-19=-303/1212, 17-18=-262/933, 16-17=-212/668, 15-16=-164/437 WEBS 4-21=-296/83, 5-19=-377/45, 6-19=-85/420, 6-18=-552/123, 7-18=-174/626, 7-17=-691/196, 8-17=-242/780, 8-16=-801/254, 9-16=-291/850, 9-15=-846/300, 10-15=-347/942, 10-14=-880/345, 11-14=-402/848, 11-13=-824/326, 2-21=-189/1062 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) All plates are 4x6 MT20 unless otherwise indicated. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 13=407, 22=195. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 130 lb down and 28 lb up at 0-7-12, 115 lb down and 37 lb up at 2-7-12, 115 lb down and 34 lb up at 4-7-12, 123 lb down and 108 lb up at 6-7-12, 123 lb down and 108 lb up at 8-7-12, 123 lb down and 108 lb up at 10-7-12, and 123 lb down and 108 lb up at 12-7-12, and 133 lb down and 98 lb up at 14-7-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).Continued on page 2 June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss TG03 Truss Type Roof Special Girder Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729301 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:51 2021 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-FP4u9u5HkylcHkegvkTK88_27ObMGheVEtwDpqz33nI LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 4-5=-60, 5-6=-60, 6-7=-60, 7-8=-60, 8-9=-60, 9-10=-60, 10-11=-60, 11-12=-60, 13-22=-20 Concentrated Loads (lb) Vert: 13=-133(F) 21=-115(F) 20=-115(F) 16=-123(F) 30=-130(F) 31=-123(F) 32=-123(F) 33=-123(F) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss V01 Truss Type Valley Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729302 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:52 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-jbeGNE6vVGtTvuDsTR_ZhLXALny7?HaeTWfmMGz33nH Scale = 1:31.5 1 2 3 4 5 6 3x4 5x6 3x4 2x4 12-0-112-0-1 12-0-50-0-5 6-0-3 6-0-3 12-0-5 6-0-3 0-0-45-0-20-0-410.00 12 Plate Offsets (X,Y)-- [2:0-2-1,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.76 0.28 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=11-11-12, 3=11-11-12, 4=11-11-12 Max Horz 1=-78(LC 10) Max Uplift 1=-9(LC 12), 3=-9(LC 12) Max Grav 1=236(LC 1), 3=236(LC 1), 4=430(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-4-9 to 3-4-9, Interior(1) 3-4-9 to 6-0-3, Exterior(2R) 6-0-3 to 9-0-3, Interior(1) 9-0-3 to 11-7-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss V02 Truss Type Valley Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729303 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:52 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-jbeGNE6vVGtTvuDsTR_ZhLXC2ny8?JpeTWfmMGz33nH Scale = 1:25.0 1 2 3 4 5 6 2x4 3x4 2x4 2x4 0-0-50-0-5 8-9-158-9-10 4-5-0 4-5-0 8-9-15 4-5-0 0-0-43-8-20-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.58 0.28 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=8-9-5, 3=8-9-5, 4=8-9-5 Max Horz 1=-57(LC 10) Max Uplift 1=-16(LC 12), 3=-16(LC 12) Max Grav 1=188(LC 1), 3=188(LC 1), 4=285(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-7 to 3-3-7, Interior(1) 3-3-7 to 4-5-0, Exterior(2R) 4-5-0 to 7-5-0, Interior(1) 7-5-0 to 8-6-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss V03 Truss Type Valley Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729304 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:53 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-BoBeaa7XGZ?KW2o308VoDZ4TnBL7kmdniAPKuiz33nG Scale = 1:17.5 1 2 3 4 2x4 3x4 2x4 2x4 0-0-50-0-5 5-7-95-7-4 2-9-12 2-9-12 5-7-9 2-9-12 0-0-42-4-20-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.20 0.11 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-6-15, 3=5-6-15, 4=5-6-15 Max Horz 1=-35(LC 10) Max Uplift 1=-10(LC 12), 3=-10(LC 12) Max Grav 1=115(LC 1), 3=115(LC 1), 4=175(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss V04 Truss Type Valley Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729305 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:54 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-g_l0ow8A1t7B8BNFas01mmchDbh_TDDxwq8tQ9z33nF Scale = 1:7.8 1 2 3 2x4 2x4 2x4 0-0-50-0-5 2-5-22-4-13 1-2-9 1-2-9 2-5-2 1-2-9 0-0-41-0-20-0-410.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.03 0.07 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 4 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-5-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-4-9, 3=2-4-9 Max Horz 1=-13(LC 10) Max Grav 1=74(LC 1), 3=74(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss V05 Truss Type Valley Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729306 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:55 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-8AJP?G8ooBF2mLyR8ZXGI_9li??OCgq49UuQzbz33nE Scale = 1:16.6 1 2 3 4 5 6 7 8 2x4 3x4 2x4 2x4 8-7-98-7-9 8-8-10-0-8 4-4-0 4-4-0 8-8-1 4-4-0 0-0-42-2-00-0-46.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.49 0.25 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=8-7-1, 3=8-7-1, 4=8-7-1 Max Horz 1=-25(LC 10) Max Uplift 1=-9(LC 12), 3=-9(LC 12) Max Grav 1=156(LC 1), 3=156(LC 1), 4=307(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-5-9 to 3-5-9, Interior(1) 3-5-9 to 4-4-0, Exterior(2R) 4-4-0 to 7-4-0, Interior(1) 7-4-0 to 8-2-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21103756 Truss V06 Truss Type Valley Qty 1 Ply 1 79 Sunrise Job Reference (optional) I46729307 8.430 s Jun 2 2021 MiTek Industries, Inc. Thu Jun 24 12:38:55 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-8AJP?G8ooBF2mLyR8ZXGI_9rq?_aCgT49UuQzbz33nE Scale = 1:8.7 1 2 3 2x4 2x4 2x4 0-0-80-0-8 4-8-14-7-9 2-4-0 2-4-0 4-8-1 2-4-0 0-0-41-2-00-0-46.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.10 0.30 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-7-1, 3=4-7-1 Max Horz 1=12(LC 11) Max Grav 1=150(LC 1), 3=150(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 25,2021 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths