HomeMy WebLinkAboutM002.0Indianapolis Design Center352 South County Road 300 EDanville, IN 46122317-745-9984These placement plans have been prepared with the specifications of TrussJoist products based on project information provided. This service is solely intendedfor product application assurance; and, is not intended to circumvent the needfor a design professional as determined by the building codes. The designerof record and/or builder/framer is responsible to assure these drawings arecompatible with the overall project. These documents are not intended to replacethe building plan (which should be used to determine bearing placement).Please insure measurements of the foundation match those provided at the timeof design. Builder is responsible to place load bearing members in load path.Architectural Drawings Prepared By: Structural Drawings Prepared By: 84 Lumber FranklinKevin BeherPyatt BuildersTG90Rev. By Date CommentsDrawn By:DWChecked By: Date:CM 06/17/2021Tribeca
25065
Sheet
1 of 1
Main Floor System
Not to Scale
Confirm this layout with the builder and designer of record. Make
sure all discrepencies are corrected before ordering floor system.
All Dimensions are Approximate and Must Be Field Verified. 11 7/8" TJI Joists 19.2" O.C. Spacing 11 7/8" TJI Joists 24" O.C. SpacingFraming Connector Summary
PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff
H1 1 Simpson HSUR410 Designed 20- SD9212 - 6- SD9212 45 (R) - No No No
H2 1 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- Strong-Grip - - 2 No No
H3 5 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- 10dx1.5 - - No No Yes
H4 1 Simpson SUL1.81/11 Designed 16- 10dx1.5 - 6- 10dx1.5 45 (L) - No No No
H5 1 Simpson SUR1.81/11 Designed 16- 10dx1.5 - 6- 10dx1.5 45 (R) - No No Yes
H6 1 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- 10dx1.5 - - 2 No Yes
Products
PlotID Length Product Plies Net Qty
FJ201 18' 0" 11 7/8" TJI 110 joist 1 12
FJ202 10' 0" 11 7/8" TJI 110 joist 1 2
FJ203 6' 0" 11 7/8" TJI 110 joist 1 1
FJ204 4' 0" 11 7/8" TJI 110 joist 1 5
FJ205 36' 0" 11 7/8" TJI 360 joist 1 2
FJ206 20' 0" 11 7/8" TJI 360 joist 2 2
FJ207 18' 0" 11 7/8" TJI 360 joist 1 3
FJ208 22' 0" 11 7/8" TJI 560 joist 1 6
FJ209 20' 0" 11 7/8" TJI 560 joist 1 1
FJ210 18' 0" 11 7/8" TJI 560 joist 1 2
BM201 20' 0" 1 3/4" x 16" 2.0E Microllam LVL 2 2
BM202 4' 0" 1 3/4" x 7 1/4" 2.0E Microllam LVL 2 6
BM203 20' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2
BM204 10' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2
BM205 6' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2
BM206 4' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1
Ca201 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 11
Blocking
PlotID Length Product Plies Net Qty
Bk201 2' 0" 11 7/8" TJI 110 joist 1 28
LEVEL NOTES
Current Date: 6/17/2021
File Name: tg90_25065.jvl
Level Name: Second Floor System
Building Code - Design Methodology: IBC 2006
Members with Design Overridden:
TJ-Pro Rating (Weighted Average): 40
Minimum Level TJ - Pro Rating & Joist: TJ-Pro rating = 35, joist = FJ205(i11126)
Maximum Level TJ - Pro Rating & Joist: TJ-Pro rating = 65, joist = FJ202(i11141)
FLOOR
Floor Container: FC1
Use/Occupancy: ResidentialLivingAreas
Floor Area Loading is: 40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load
Operator Added Additional Loads
Maximum Allowed Deflection: L/480 Live Load & L/240 Total Load
TJ-Pro Rating Information:
Weighted Average: 40
Directly Applied Ceiling: Gypsum 1/2"
Decking Attachment: Glue and Nail
Decking Material: 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF
Perpendicular Partition: No
Strapping at max 8' o.c.: None
Blocking at max 8' o.c.: No
Poured Flooring: No
A3
A3
A3
A3
H2
B1W
B1
E1
E1
B1
BM203
BM202BM202BM202BM201
FJ208
FJ208
FJ208
FJ208
FJ208
FJ207
FJ205
FJ210
FJ205
FJ207
FJ207
FJ201
FJ201
FJ201
FJ210
FJ201
FJ201
FJ201
FJ201
FJ201
FJ201
FJ201
FJ201
FJ202
FJ202
Ca201
Ca201
Ca201
Ca201
Ca201
Ca201
Ca201Ca201Ca201Ca201Ca201Bk201 Bk201Bk201FJ204FJ204FJ204FJ204FJ204 FJ203H2
H6
FJ208
FJ206
FJ209Bk201
Bk201
VO1
VO2
VO3
VO4 FJ201 1' 0"2' 0" 1' 0" 1' 6 3/4"11 7/8"2' 5 3/8" 2' 0" 2' 0" 1' 0" 2' 0" 2' 4"
8' 11 7/8"11 3/4"BM206
BM205BM204H3
H3H3H3H3H1 H4
H5Flush beam depth greater than floor joist depth. Verify all
loading and framing conditions prior to construction.An additional 8 PSF area dead load has been addedto account for tile load in the MBA on this floor.There are different joist series of the same
depth specified on this floor system. Verify
when installing that the proper TJI® joists
are used in the appropriate area.
07/16/21