Loading...
HomeMy WebLinkAboutKimley-Horn - Indianapolis - Bid Set 5.26.2021_A0.51.01 FIRE RATED CONSTRUCTION DESIGN REQUIREMENTS: MAINTAIN BARRIER AND STRUCTURAL FLOOR FIRE RESISTANCE RATINGS INCLUDING RESISTANCE TO COLD SMOKE AT PENETRATIONS, CONNECTIONS AND OTHER SURFACES OR TYPES OF CONSTRUCTION, AT SEPARATION REQUIRED TO PERMIT BUILDING MOVEMENT AND SOUND OR VIBRATION ABSORPTION, AND AT OTHER CONSTRUCTION GAPS. 1.02 LATEX AND ACRYLIC BASED SEALANTS ARE NOT ACCEPTABLE. USE ONLY URETHANE OR SILICONE BASE MATERIALS. 1.03 SMOKE BARRIER CONSTRUCTION DESIGN REQUIREMENTS: MAINTAIN BARRIER AND STRUCTURAL FLOOR RESISTANCE TO COLD SMOKE AT ALL PENETRATIONS, CONNECTIONS AND OTHER SURFACES AND TYPES OF CONSTRUCTION AND AT ALL SEPARATIONS REQUIRED TO PERMIT BUILDING MOVEMENT AND SOUND OR VIBRATION ABSORPTION, AND AT OTHER CONSTRUCTION GAPS. 1.04 ASSEMBLY DESIGNS ARE SPECIFIED GENERALLY UNDER UL SYSTEM CATEGORIES BY PENETRATING ITEM. MANUFACTURERS' PRODUCT APPLICATIONS MUST HAVE SPECIFIC UL SYSTEM DESIGNATIONS. 1.05WALL TO FLOOR JOINTS: HW-D-0000 CATEGORIES. 1.06 DUCT DAMPER PENETRATION: COMPLETE FILL ANNULAR SPACE WITH MINERAL WOOL SAFING AND SEAL WITH FLEXIBLE FIRE STOP SEALANT. COMPLY WITH DUCT DAMPER MANUFACTURER'S REQUIREMENTS. 2.01 SYSTEMS OR DEVICES LISTED IN THE UL FIRE-RESISTANCE DIRECTORY UNDER CATEGORIES XHCR AND XHEZ MAY BE USED, PROVIDING THAT THEY CONFORM TO THE CONSTRUCTION TYPE, PENETRATE TYPE, ANNULAR SPACE REQUIREMENTS, AND FIRE RATING INVOLVED IN EACH SEPARATE INSTANCE, AND THAT THE SYSTEM BE SYMMETRICAL FOR WALL APPLICATIONS. SYSTEMS OR DEVICES MUST BE ASBESTOS-FREE. 2.02 ADDITIONAL REQUIREMENTS: WITHSTAND THE PASSAGE OF COLD SMOKE EITHER AS AN INHERENT PROPERTY OF THE PRODUCT, OR BY THE USE OF A SEPARATE PRODUCT INCLUDED AS A PART OF THE UL SYSTEM OR DEVICE, AND DESIGNED TO PERFORM THIS FUNCTION. 2.03 THROUGH-PENETRATION SMOKE-STOPPING: ANY SYSTEM COMPLYING WITH REQUIREMENTS FOR THROUGH- PENETRATION FIRE STOPPING IN FIRE RATED CONSTRUCTION, AS SPECIFIED IN THIS SECTION, IS ACCEPTABLE, PROVIDED SYSTEM PROVIDES A SMOKE SEAL. 2.04 CONSTRUCTION-GAP SMOKE-STOPPING: ANY SYSTEM COMPLYING WITH REQUIREMENTS FOR CONSTRUCTION-GAP FIRE STOPPING IN FIRE RATED CONSTRUCTION, AS SPECIFIED IN THE SECTION, IS ACCEPTABLE, PROVIDED SYSTEM PROVIDES A SMOKE SEAL. 2.05 FILL, VOID OR CAVITY MATERIALS: AS CLASSIFIED UNDER CATEGORY XHHW IN UL FIRE RESISTANCE DIRECTORY. 2.06 FORMING MATERIALS: AS CLASSIFIED UNDER CATEGORY XHKU IN UL FIRE RESISTANCE DIRECTORY. 2.07 ACCESSORIES: AS REQUIRED BY MANUFACTURERS LISTED, TESTED OR ENGINEERED FIRE STOP SYSTEM ASSEMBLIES. 3.01 COMPLY WITH FIRE STOPPING MATERIAL MANUFACTURER'S RECOMMENDATIONS, AND UL SYSTEM OR DESIGN. 3.02 WARNING LABELS: LABEL EACH PENETRATION AS REQUIRED BY JURISDICTION. SECTION 078400 -FIRE STOPPING 1.01 PROVIDE SEALANT MATERIALS SUITED FOR INDICATED USE FOR A WEATHER AND WATER TIGHT INSTALLATION. SEALANTS SHALL BE COMPATIBLE WITH ADJACENT MATERIALS. PROVIDE JOINT SEALANT AND ACCESSORIES FOR EACH TYPE OF JOINT FROM A SINGLE SOURCE. UNLESS OTHERWISE NOTED, AREAS TO BE CAULKED INCLUDE: GLASS WINDOWS, EXTERIOR DOOR FRAMES, SILLS, AND THRESHOLDS, WOOD ON WOOD TRIM JOINTS AND SPLICES; SINKS AND TOILETS TO WALLS AND FLOORS; DRYWALL TO ALUMINUM AND HOLLOW METAL WINDOW/DOOR FRAMES; JOINTS NECESSARY TO PROVIDE A WATERTIGHT CONDITION. 1.02 SUBMITTALS: A. MANUFACTURER'S LITERATURE STATING PRODUCTS ARE COMPATIBLE WITH PROPOSED APPLICATIONS. B. PRODUCT DATA INDICATING SEALANT CHEMICAL CHARACTERISTICS, PERFORMANCE CRITERIA, LIMITATIONS, COLOR AVAILABILITY AND APPLICATION INSTRUCTIONS. C. SUBMIT (1) SAMPLE 1/4" IN DIAMETER X 4" IN SIZE ILLUSTRATING MANUFACTURER'S FULL LINE OF COLOR SELECTIONS FOR EACH EXPOSED PRODUCT FOR SELECTION BY THE ARCHITECT. 1.03 QUALITY ASSURANCE: JOINT SEALANT SHALL MAINTAIN PERMANENTLY AIRTIGHT AND WATERTIGHT CONTINUOUS SEALS, WITHIN RECOGNIZED LIMITATIONS OF WEAR AND AGING. FAILURE TO PRODUCE SUCH A SEAL WILL BE RECOGNIZED AS A FAILURE OF MATERIALS AND WORKMANSHIP. 1.04 MATERIALS: SEALANT TYPE APPLICATION: 1. POLYURETHANE HORIZONTAL CONTROL JOINTS IN CONCRETE FLOORING AND (SELF LEVELING) ATJUNCTURES BETWEEN THIS MATERIAL AND ADJACENT MATERIALS. COMPLY WITH ASTM C-920. 2. SILICONE SEALING OF JOINTS BETWEEN COUNTER SPLASHES AND (GEN. PURPOSE) ADJACENT TOPS & WALLS. COMPLY WITH ASTM C-920. 3. SILICONE GENERAL CAULKING AS PART OF INTERIOR PAINTING IN JOINTS (PAINTABLE) SUBJECT TO MOVEMENT. 4. ACRYLIC LATEX GENERAL CAULKING AS PART OF INTERIOR PAINTING COMPLY WITH ASTM C-834. 1.05PROVIDE TWO (2) YEAR WARRANTY, AT MINIMUM. 2.01 1-PART POLYURETHANE SEALANTS: POLYURETHANE BASE 1 PART ELASTOMERIC SEALANT, COMPLYING WITH FED. SPEC. TT-S-00230C, TYPE II CLASS A, WITH ELONGATION AND COMPRESSION OF NOT LESS THAT 25 PERCENT. ASTM C-920, TYPE S, CLASS 25, GRADE NS. USE FOR INTERIOR JOINTS SUBJECT TO MOVEMENT. 2.02 HIGH MODULUS SILICONE RUBBER SEALANT: ONE PART NONACID-CURING SILICONE. USE FOR JOINTS RELATED TO STRUCTURAL GLAZING. 2.03 MILDEW-RESISTANT SILICONE RUBBER SEALANT: SILICONE RUBBER BASE, 1 PART MILDEW RESISTANCE SEALANT WITH INTEGRAL FUNGICIDE COMPLYING WITH FED. SPEC. TT-S-001543, CLASS A. SPECIFICALLY RECOMMENDED BY MANUFACTURER FOR INTERIOR JOINTS IN WET AREAS AROUND PLUMBING FIXTURES AND CERAMIC TILE. USE FOR JOINTS IN CERAMIC TILE WALLS AND FLOORS, AROUND EQUIPMENT, AND AROUND PLUMBING FIXTURES. 2.04 ACRYLIC SEALANTS: GENERAL PURPOSE, PAINTABLE ACRYLIC-EMULSION SEALANT WITH PLUS 7.5 PERCENT TO MINUS 7.5 PERCENT MOVEMENT. COMPLYING WITH ASTM C834. USE FOR INTERIOR JOINTS NOT SUBJECT TO MOVEMENT. 2.05 FOAM GASKET SEAL: PRE COMPRESSED, IMPREGNATED OPEN-CELL FOAM SEALANT INCORPORATING PERMANENTLY ELASTIC OPEN CELL POLYURETHANE FOAM, MANUFACTURER'S STANDARD IMPREGNATING AGENT, AND PRESSURE SENSITIVE BACKING. RESILIENT TO -26 DEGREES F FOR EXTERIOR USE AND WHERE OTHERWISE SUBJECT TO LOW TEMPERATURES. 2.06 PRIMER: AS RECOMMENDED BY SEALANT MANUFACTURER. 2.07 BOND BREAKER: PRESSURE-SENSITIVE ADHESIVE POLYETHYLENE TAPE. 2.08 JOINT CLEANER: NON-CORROSIVE AND NON-STAINING TYPE, RECOMMENDED BY SEALANT MANUFACTURER; COMPATIBLE WITH JOINT FORMING MATERIALS. 2.09 COLORS: SEALANT COLOR SHALL BE SELECTED BY ARCHITECT FROM MANUFACTURER'S STANDARD COLORS. 3.01 PREPARATION OF JOINTS, CLEANING, PRIMING, STORAGE AND HANDLING OF SEALANTS AND PARTICULAR METHODS OF INSTALLATION SHALL CONFORM TO RECOMMENDATIONS OF SEALANT MANUFACTURER FOR EACH SPECIFIC TYPE OF INSTALLATION. 3.02 SEALANT DEPTH SHALL BE 2 TO ONE TIMES THE JOINT WIDTH, BUT NOT LESS THAT 1/4 INCH OR MORE THAN 2 INCH UNLESS OTHERWISE REQUIRED IN SPECIAL CASES. 3.03 APPLY SOLID AND CONTINUOUS BEAD OR BED OF SEALANT TO FILL JOINT WITHOUT VOIDS. CONFINE SEALANT TO JOINT OR AREAS TO BE SEALED AND FINISH TO NEAT STRAIGHT LINES. 3.04 ALL SEALANTS TO MEET THE FOLLOWING MINIMUM VOC LIMIT REQUIREMENTS; SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE 1168. A. ARCHITECTURAL -250 G/L B. POROUS ARCHITECTURAL SEALANT PRIMER -775 G/L C. NON-POROUS ARCHITECTURAL SEALANT PRIMER -250 G/L 3.05 ALL ARCHITECTURAL COATINGS TO MEET THE FOLLOWING MINIMUM VOC LIMIT REQUIREMENTS; SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE 1133. A. BOND BREAKERS -350 G/L 3.06 ALL AEROSOL ADHESIVES TO MEET THE FOLLOWING MINIMUM VOC LIMIT REQUIREMENTS; GREEN SEAL STANDARD GS-36. A. GENERAL PURPOSE MIST SPRAY -65% VOC'S BY WEIGHT SECTION 079000 -JOINT SEALANTS 1.01 STEEL DOORS AND FRAMES SHALL COMPLY WITH ANSI/SDI 100 AND THE REQUIREMENTS SPECIFIED. 1.02 SUBMIT: MANUFACTURER'S PRODUCT DATA, INCLUDING SPECIFICATIONS, SHOP DRAWINGS COVERING EACH TYPE OF DOOR, FRAME, FRAME CONDITION AND COMPLETE ANCHORAGE DETAILS. INCLUDE SCHEDULE AND FOLLOW DOOR NUMBERING SYSTEM USED ON ARCHITECTURAL DRAWINGS. 1.03 DELIVERY, STORAGE, AND HANDLING: COMPLY WITH MANUFACTURER'S ORDERING INSTRUCTION AND LEAD TIME REQUIREMENTS TO AVOID CONSTRUCTION DELAYS. DELIVER MATERIAL IN MANUFACTURER'S ORIGINAL UNOPENED UNDAMAGED CONTAINERS WITH IDENTIFICATION LABELS INTACT. STORE MATERIALS PROTECTED FROM EXPOSURE TO HARMFUL WEATHER CONDITIONS. COMPLY WITH MANUFACTURER'S RECOMMENDATIONS FOR STORAGE AND HANDLING. DOORS AND FRAMES SHALL BE STORED IN AN UPRIGHT POSITION. 1.04 WARRANTY: DOORS SHALL BE WARRANTED BY THE MANUFACTURER TO BE FREE FROM MANUFACTURING DEFECTS FOR A PERIOD OF NOT LESS THAN 18 MONTHS FROM THE DATE OF SUBSTANTIAL COMPLETION. WARRANTY SHALL PROVIDE FOR REPAIR OR REPLACEMENT OF THE DOOR AS ORIGINALLY INSTALLED. 2.01 DOORS: COMMERCIAL-QUALITY COLD-ROLLED SHEET STEEL; STEEL FOR DOOR FACES SHALL BE STRETCHER LEVELED. HEAVY DUTY, SEAMLESS, IN ACCORDANCE WITH THE REQUIREMENTS OF SDI 100 FOR GRADE II, MODEL 3 DOORS. INTERIOR SHALL BE 18 GAUGE, 1-3/4 INCHES THICK. 2.02 FRAMES: ONE PIECE, FULLY WELDED, 16 GAUGE, COLD OR HOT-ROLLED SHEET STEEL. 2.03 ANCHORS: PROVIDE ANCHORS AT EACH JAMB AS FOLLOWS FOR EACH 2'-6" OF DOOR HEIGHT OR FRACTION THEREOF: FABRICATE FROM MINIMUM 12 GAUGE SHEET STEEL. VARY ANCHOR TYPES TO PROVIDE POSITIVE FASTENING TO ADJACENT CONSTRUCTION. SECURE A METAL CLIP ANGLE AT BOTTOM OF EACH JAMB MEMBER FOR ANCHORING TO FLOOR, WITH A MINIMUM OF TWO FASTENERS. 2.04 PREPARE STEEL DOOR FRAMES TO RECEIVE HARDWARE. FURNISH APPROVED HARDWARE SCHEDULE, HARDWARE TEMPLATES AND SAMPLES OF PHYSICAL HARDWARE WHERE NECESSARY TO ENSURE CORRECT FITTING AND INSTALLATION. PREPARE SINKAGES AND CUTOUTS FOR MORTISED AND CONCEALED HARDWARE, HARDWARE PREPARATION FOR LABELED OPENINGS SHALL CONFORM TO THE REQUIREMENTS OF THE LABELING AUTHORITY. PROVIDE REINFORCEMENTS FOR BOTH CONCEALED AND SURFACE APPLIED HARDWARE. 2.05 GLAZED OPENINGS: LOCATIONS AND SIZES AS INDICATED ON DRAWINGS. COMPLY WITH REQUIREMENTS OF SECTION 088100. 2.06 PAINTED FINISH AS INDICATED IN FINISH SCHEDULE / FRAME TYPES / DOOR SCHEDULE. 3.01 INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND THE REQUIREMENTS OF STEEL DOOR INSTITUTE (SDI) 100, AND THE REQUIREMENTS OF THE LABELING AUTHORITY. 3.02 APPLY HARDWARE IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS, TAKING CARE NOT TO DAMAGE HARDWARE, DOORS, FRAMES AND THEIR FINISHES. ADJUST AND LUBRICATE, AS REQUIRED FOR PROPER OPERATION. SECTION 081113 -HOLLOW METAL DOORS AND FRAMES 1.01 INTERIOR FRAMES A. MANUFACTURER: 1. OMEGA MANUFACTURING 2. RACO INTERIORS 2. WESTERN INTEGRATED MATERIALS, INC. 3. FRAMEWORKS (ASSA ABLOY) B. ALUMINUM FRAMING: ASSTM B221 ALLOY 6063-T5 OR ALLOY AND TEMPER REQUIRED TO SUIT STRUCTURAL AND FINISH REQUIREMENTS, NOT LESS THAN 0.062 INCH(1.6MM) THICK. 1. PROFILE: SQUARE 2. THICKNESS: 1-1/2" PROFILE C. DOOR FRAMES: EXTRUDED ALUMINUM, REINFORCED FOR HINGES, STRIKES, AND CLOSERS. 1. 60-MINUTE FIRE PROTECTION RATING: FABRICATE ALUMINUM FRAME ASSEMBLIES WITH COLD FORMED, PRIMED, INTERIOR STEEL LINER. D. GLAZING FRAMES: EXTRUDED ALUMINUM, FOR GLAZING THICKNESS INDICATED. E. TRIM: EXTRUDED ALUMINUM, NOT LESS THAN 0.062 INCH 1. MANUFACTURER'S STANDARD TRIM 1.02 ACCESSORIES A. FASTENERS: ALUMINUM, NONMAGNETIC, STAINLESS-STEEL OR OTHER NONCORROSIVE METAL FASTENERS COMPATIBLE WITH FRAMES, STOPS,PANELS, REINFORCEMENT PLATES, HARDWARE, ANCHORS, AND OTHER ITEMS BEING FASTENED. B. DOOR SILENCERS: MANUFACTURER'S STANDARD CONTINUOUS MOHAIR, WOOL PILE, OR VINYL SEAL. COLOR TO BE SELECTED BY ARCHITECT FROM MANUFACTURERS FULL RANGE OF COLORS. C. SMOKE SEALS: INTUMESCENT STRIP OR FIRE RATED GASKETS. D. GLAZING GASKETS: MANUFACTURER'S STANDARD EXTRUDED OR MOLDED PLASTIC, TO ACCOMMODATE GLAZING THICKNESS INDICATED ON DRAWINGS. 1.03 REFER TO DOOR & FINISH SCHEDULE FOR FINISH (WD) . 2.01 INSTALLATION SHALL COMPLY WITH FRAME AND DOOR MANUFACTURER'S PRINTED INSTRUCTIONS AND APPROVED SHOP DRAWINGS. 2.03 WARRANT AGAINST DEFECTS IN MANUFACTURING OF MATERIALS FOR A PERIOD OF 2 YEARS. 2.04 WARRANT FINISH, OTHER THAN NORMAL WARRANTY, FOR A PERIOD OF 5 YEARS. SECTION 081116 -ALUMINUM DOORS AND FRAMES 1.01 QUALITY ASSURANCE: A. NON-FIRE RATED WOOD DOORS SHALL BE 5-PLY PREMIUM GRADE, BANDED CORE IN ACCORDANCE WITH WINDOW AND DOOR MANUFACTURERS ASSOCIATION "ARCHITECTURAL WOOD FLUSH DOORS" IS 1A-04. B. AWI -QUALITY STANDARDS OF THE AMERICAN WOODWORK INSTITUTE (AWI). C. FACE SPECIES: DOOR FACE VENEER SPECIES TO BE AWI GRADE AA. 1.02 SUBMITTALS: A. MANUFACTURER'S PRODUCT CONSTRUCTION DATA, INCLUDING SPECIFICATIONS, INSTALLATION INSTRUCTIONS, DETAILS OF CORE AND EDGE CONSTRUCTION, TRIM FOR LIGHT OPENINGS, AND SIMILAR COMPONENTS; SHOP DRAWINGS, INCLUDING DOOR TYPE AND SIZE, HARDWARE TYPES, LOCATIONS AND BLOCKING REQUIREMENTS, CUTOUTS, AND PRE-FINISH SYSTEM TYPE AND APPROVED COLOR INCLUDING SCHEDULE. B. SUBMIT THE FOLLOWING: 1. SHOP DRAWINGS ILLUSTRATING DOOR OPENING CRITERIA ELEVATIONS, SIZES, TYPES, SWINGS, UNDERCUTS REQUIRED, SPECIAL BEVELING ETC. 2. PRODUCT DATA. 3. ONE (1) 8" X 8" SAMPLES OF DOOR FINISH. 4. PROVIDE MANUFACTURER'S STANDARD COLOR CHARTS, FOLLOWED BY A PHYSICAL SAMPLE OF COLOR SELECTED FOR ARCHITECT'S APPROVAL. ARCHITECT HAS THE OPTION TO FURNISH A COLOR FOR THE MANUFACTURER TO MATCH. 1.03 DOORS SHALL BE WARRANTED BY THE MANUFACTURER TO BE FREE OF MANUFACTURING DEFECTS FOR THE LIFE OF THE ORIGINAL INSTALLATION. WARRANTY SHALL PROVIDE FOR REPAIR OR REPLACEMENT OF THE DOOR AS ORIGINALLY FURNISHED. 1.04 DELIVER DOOR IN PROTECTIVE WRAPPING. 2.01 PRODUCTS: SUPPLY DOORS FROM ON OF THE FOLLOWING MANUFACTURERS: ALGOMA HARDWOODS, INC.; EGGERS INDUSTRIES; MARSHFIELD DOOR SYSTEMS; VT INDUSTRIES OR EQUAL. ALL WOOD DOORS ON THE PROJECT SHALL BE BY ONE MANUFACTURER TO ENSURE UNIFORMITY IN APPEARANCE AND CONSTRUCTION. A. WOOD SPECIES: (WD) SEE FINISH SCHEDULE FOR SPECIFICATIONS 2.02 FLUSH DOORS SHALL BE SOLID CORE CONSTRUCTION, HARDBOARD OR VENEER FACING AS SPECIFIED, 1-3/4 INCH THICK. 2.03 DOORS SHALL BE FACTORY PREPARED FOR HARDWARE. 2.04 ALL WOOD DOORS SHALL BE COMPLETELY FACTORY FINISHED USING THE MANUFACTURER'S STANDARD FINISH THAT MEETS OR EXCEEDS THE PERFORMANCE CRITERIA FOR AWI UV CURABLE POLYESTER URETHANE FINISH SYSTEM OR CONVERSION VARNISH. 3.01 INSTALL DOORS IN ACCORDANCE WITH WDMA IS 1A-04 AND SPECIFIC MANUFACTURER'S INSTALLATION INSTRUCTION. FIT TO FRAMES AND PREPARE FOR HARDWARE NOT PRE-FITTED AT FACTORY. DOORS SHALL BE PLUMB IN ALL POSITIONS, FLAT IN THE FRAME AND SHALL OPERATE SMOOTHLY AND QUIETLY. 3.02 PROTECT DOORS FOLLOWING INSTALLATION FROM DAMAGE AS A RESULT OF PROJECT COMPLETION. 3.03 UNDERCUT DOORS 1/2" (3/4" AT RESTROOMS) MAX. TO FINISHED FLOOR UNLESS NOTED OTHERWISE. TOUCH-UP DOOR FINISH AFTER UNDERCUTTING. 3.04 PROVIDE TWO (2) YEAR INSTALLER WARRANTY. SECTION 081416 -FLUSH WOOD DOORS 2.01 FRAME SHALL BE MINIMUM 12 GAUGE STEEL WITH MINIMUM 0.75 INCHES STEEL DOOR PANELS. FURNISH DOORS WITH DRYWALL BEAD GALVANIZED STEEL, HARDWARE MANUFACTURER'S STANDARD AND FACTORY APPLIED BAKED ENAMEL PRIME COAT FINISH. 2.02 FABRICATE DOORS WITH CONCEALED, SPRING TYPE HINGES OPENING TO 175 DEGREES AND FLUSH, SCREWDRIVER OPERATED LOCKS WITH METAL CAMS. 2.03 WALL ACCESS DOORS: FOR FLUSH INSTALLATION IN GYPSUM WALLBOARD; MILCOR STYLE DW MANUFACTURED BY INRYCO, INC.; NYSTROM. ACCESS DOORS IN FIRE-RATED WALLS SHALL BE FIRE RATED AS REQUIRED. NOMINAL 12 INCH SQUARE. 2.04 CEILING ACCESS DOORS, DOWNWARD OPENING: A. RECESSED PANEL TYPE: FOR INSTALLATION OF ACOUSTICAL MATERIAL, BILCO CD-1; MILCOR INRYCO, INC., OR APPROVED EQUAL, NOMINAL 300MM SQUARE FOR ACCESS TO VALVES, AND 24 INCH SQUARE FOR ACCESS TO DUCTS. B. FLUSH TYPE: FOR INSTALLATION IN GYPSUM WALLBOARD CEILINGS, SIMILAR TO RECESSED PANEL TYPE, EXCEPT WITH FLUSH PANEL, NOMINAL 12 INCHES SQUARE FOR ACCESS TO VALVES, AND 24 INCHES SQUARE FOR ACCESS TO DUCTS. 3.01 INSTALL ACCESS DOORS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTION AND SHOP DRAWINGS AS APPROVED, FOR ACCESS TO VALVES, DUCTWORK, AND OTHER WORK PROVIDED. SECTION 083113 -ACCESS DOORS & FRAMES 1.01 SUBMIT: MANUFACTURER'S PRODUCT CONSTRUCTION DATA, INCLUDE DETAILS OF CONSTRUCTION RELATIVE TO MATERIALS, DIMENSION OF INDIVIDUAL COMPONENTS, PROFILES AND FINISHES; SHOP DRAWINGS, INCLUDING DOOR TYPE AND SIZE, HARDWARE TYPES AND QUANTITIES, DETAILS OF FITTINGS, LOCATIONS AND INSTALLATION REQUIREMENTS. 1.02 FIELD MEASUREMENTS: VERIFY OPENING DIMENSIONS OF ALL GLASS ENTRANCES BY FIELD MEASUREMENTS BEFORE FABRICATION AND INDICATE MEASUREMENTS ON SHOP DRAWINGS. COORDINATE FABRICATION SCHEDULE WITH CONSTRUCTION PROGRESS TO AVOID DELAYING WORK. ESTABLISHED DIMENSIONS: WHERE FIELD MEASUREMENTS CANNOT BE MADE WITHOUT DELAYING THE WORK, ESTABLISH OPENING DIMENSIONS AND PROCEED WITH FABRICATING ALL GLASS ENTRANCES WITHOUT FIELD MEASUREMENTS. COORDINATE CONSTRUCTION TO ENSURE ACTUAL OPENING DIMENSIONS CORRESPOND TO ESTABLISHED DIMENSIONS. 2.01 PRODUCTS: BLUMCRAFT, C.R. LAURENCE, ACI GLASS PRODUCTS OR EQUAL. 1/2 INCH CLEAR, FULLY TEMPERED GLASS WITH FLAT POLISHED EXPOSED EDGES. A. MANUFACTURER'S CONCEALED ANCHORS AND FASTENINGS, OVERHEAD DOORSTOP AND 90 DEGREE HOLD OPEN. BACK-TO-BACK DOOR PULLS FROM MANUFACTURER'S STANDARD SELECTION. B. MANUFACTURER'S STANDARD CONTINUOUS HORIZONTAL RAILS AT DOOR AND SIDELIGHT TOP AND BOTTOM, 4 INCH SQUARE PROFILE, SATIN STAINLESS STEEL FINISH. 2.02 HARDWARE: 1. AT SWING DOORS PROVIDE TOP AND BOTTOM PIVOTS WITH ADJUSTMENT MECHANISM FOR ALIGNING DOOR. BOTTOM PIVOT RECESSED AND CONCEALED IN FLOOR AND TOP PIVOT CONCEALED IN MOUNTING CHANNEL INSTALLED ABOVE CEILING. PROVIDE HEAVY DUTY CONCEALED CLOSER ALONG WITH THE NECESSARY INSTALLATION ACCESSORIES. SELECT ACTION APPROPRIATE TO LOCATION. AT DOOR OPENINGS AT STRUCTURED SLABS PROVIDE TOP CLOSER. 2. AT SLIDING DOORS PROVIDE WHEELED ADJUSTABLE CARRIERS DESIGNED TO ATTACH TO GLASS DOOR PANEL. PROVIDE FLOOR GUIDES AND STOPS 3. PROVIDE CONTINUOUS TOP RAILS, BOTTOM RAILS, AND/OR PATCHES AS INDICATED IN DRAWINGS. PROVIDE RAIL SECTIONS FABRICATED FROM EXTRUDED ALUMINUM ALLOY AND TEMPERED AS RECOMMENDED BY MANUFACTURER FOR STRENGTH CORROSION RESISTANCE, AND SPECIFIED FINISH, BUT NOT LESS THAN 27,000 PSI ULTIMATE STRENGTH, AND NOT LESS THAN 0.125 IN. THICKNESS AT ANY LOCATION. TOP EDGE OF BOTTOM RAIL TO BE SLOPED TO CONFORM TO LOCAL CODES AND ADA REQUIREMENTS 4. PROVIDE ALL OTHER REQUIRED HARDWARE INCLUDING LOCKS, EXIT DEVICES, SECURITY EQUIPMENT, AND DECORATIVE PULLS AS INDICATED IN DRAWINGS. 3.01 INSTALLATION: INSTALL ALL GLASS ENTRANCES AND ASSOCIATED COMPONENTS ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS. SET UNITS LEVEL AND PLUMB. MAINTAIN UNIFORM CLEARANCES BETWEEN ADJACENT COMPONENTS. LUBRICATE HARDWARE AND OTHER MOVING PARTS ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS. SET, SEAL AND GROUT FLOOR CLOSER CASES AS REQUIRED BY HARDWARE AND SUBSTRATE. 3.02 DESIGN, SIZE COMPONENTS, AND INSTALL ALL-GLASS DOOR ASSEMBLY IN ACCORDANCE WITH ASTM E1300 TO WITHSTAND LOADS WITHOUT BREAKAGE, LOSS, FAILURE OF SEALS, PRODUCT DETERIORATION, AND OTHER DEFECTS. 3.03 SAFETY GLAZING: COMPLY WITH CONSUMER PRODUCT SAFETY COMMISSION 16 CFR 1201, ANSI Z97.1, AND OTHER APPLICABLE SAFETY REQUIREMENTS. EACH PIECE OF SAFETY GLAZING SHALL BE PERMANENTLY LABELED WITH APPROPRIATE MARKING. 3.04 GLASS TYPE AND THICKNESS SHALL BE DETERMINED BY GLASS DOOR MANUFACTURER TO ACCOMMODATE PROJECT DESIGN AND PERFORMANCE REQUIREMENTS. PROVIDE SIZE AND PROFILES INDICATED ON DRAWINGS. PROVIDE STRAIGHT, SHARPLY DEFINED LINES AND AREAS. GLASS THICKNESS SHALL NOT BE LESS THAN 1/2" THICK. GLASS TO BE CLEAR AND TEMPERED WITH POLISHED-FINISH RADIUSED ("PENCILED") EDGES. SECTION 084226 -ALL-GLASS ENTRANCES 1.01 FURNISH COMPLETE HARDWARE SCHEDULE AND PRODUCT CATALOG CUTS FOR APPROVAL BY ARCHITECT. A STATEMENT OF OMISSION, DISCREPANCY, OR ERROR SHOULD BE DIRECTED TO ARCHITECT WHERE ITEMS OF HARDWARE NOT DEFINITELY OR CORRECTLY SPECIFIED ARE REQUIRED FOR COMPLETION OF WORK. 1.02 FURNISH HARDWARE TEMPLATES NECESSARY FOR PREPARATORY WORK AND HARDWARE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 1.03 DELIVER EACH HARDWARE ITEM OR SET SEPARATELY PACKAGED AND IDENTIFIED FOR USE IN THE WORK. 2.01 SUBMIT THE FOLLOWING: 1. HARDWARE SCHEDULE. 2. PRODUCT DATA. 2.02 HARDWARE (HW): SEE DOOR & FINISH SCHEDULE FOR SPECIFICATIONS. 2.03 ELECTRONIC SECURITY: WHERE INDICATED, PROVIDE ELECTRIC LATCH RETRACTION PANIC DEVICES, ELECTRIC HINGES, DOOR CONTACT, POWER SUPPLIES, AND RELATED SUPPORT DEVICES TO INTERFACE WITH CARD READERS. REFER TO KIMLEY-HORN SECURITY SPECIFICATIONS/SHEET A0.7 3.01 INSTALL HARDWARE IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND APPLICABLE SECURITY AND ENERGY CONSERVATION REGULATIONS, UNLESS OTHERWISE NOTED, MOUNT LEVERS, PUSH/PULL PLATES, HANDLES, LOCKS, ETC. AT MANUFACTURER'S STANDARD MOUNTING HEIGHTS, BUT IN NO CASE GREATER THAN ADA REQUIREMENTS WHERE APPLICABLE. 3.02 PROVIDE ENTRANCE CYLINDERS TO GLAZING CONTRACTOR FOR ENTRANCES. 3.03 FIRE-RATED OPENINGS: PROVIDE HARDWARE FOR FIRE-RATED OPENINGS IN COMPLIANCE WITH NFPA 80. THIS REQUIREMENT TAKES PRECEDENCE OVER OTHER REQUIREMENTS FOR SUCH HARDWARE. PROVIDE ONLY SUCH HARDWARE WHICH HAS BEEN TESTED AND LISTED BY UL FOR THE TYPE AND SIZE OF DOOR REQUIRED, AND COMPLIES WITH THE REQUIREMENTS OF THE DOOR AND THE DOOR FRAME LABELS. LATCHING HARDWARE, DOOR CLOSERS, BALL BEARING HINGES, AND SEALS ARE REQUIRED WHETHER OR NOT LISTED IN THE HARDWARE SCHEDULE. 1. WHERE PANIC EXIT DEVICES ARE REQUIRED ON FIRE-RATED DOORS, PROVIDE SUPPLEMENTARY MARKING ON DOOR UL LABEL ON EXIT DEVICE INDICATING "FIRE EXIT HARDWARE." 3.04 KEYING WILL BE COORDINATED BETWEEN TENANT, OWNER AND/OR LANDLORD. 3.05PROVIDE TWO (2) YEAR WARRANTY. SECTION 087100 -DOOR HARDWARE 1.01 FURNISH AND INSTALL GLASS, MIRROR, AND GLAZING IN SIZES, TYPES AND LOCATIONS INDICATED, INCLUDING SETTING HARDWARE, GASKETS, AND SEALANTS NEEDED FOR A COMPLETE WEATHER TIGHT INSTALLATION. GLAZING MATERIALS, AS APPLICABLE, SHALL CONFORM TO ANSI A97.1, 16 CODE OF FEDERAL REGULATIONS (CFR) 1201 AND IBC SECTION 2403. A. EACH PANE SHALL BARE THE MANUFACTURER'S MARK DESIGNATING THE TYPE AND THICKNESS OF THE GLASS OR GLAZING MATERIAL. THE IDENTIFICATION SHALL NOT BE OMITTED UNLESS APPROVED AND AN AFFIDAVIT IS FURNISHED BY THE GLAZING CONTRACTOR CERTIFYING THAT EACH LIGHT IS GLAZED IN ACCORDANCE WITH APPROVED CONSTRUCTION DOCUMENTS. AN AFFIDAVIT MAY NOT BE SUBMITTED FOR TEMPERED GLASS THAT MUST BE PERMANENTLY IDENTIFIED. 1.02 SUBMITTALS: SHOP DRAWINGS SHOWING SIZE AND TYPE OF EACH PRODUCT SPECIFIED; SAMPLES FOR EACH TYPE OF TINTED GLASS FOR ARCHITECT'S APPROVAL. 1.03 WARRANTY: PROVIDE MANUFACTURER'S WRITTEN WARRANTY COVERING MANUFACTURING DEFECTS FOR THE FOLLOWING PERIODS: INSULATED GLASS -10 YEAR; FLOAT GLASS -5 YEAR; LAMINATED GLASS -4 YEAR; MIRRORS -15 YEAR SILVER SPOILAGE; BULLET RESISTIVE GLASS -2 YEARS. 1.04 EACH PANE OF TEMPERED GLASS, EXCEPT TEMPERED SPANDREL GLASS SHALL BE PERMANENTLY IDENTIFIED BY THE MANUFACTURER. THE IDENTIFICATION MARK SHALL BE ACID ETCHED, SAND BLASTED, CERAMIC FIRED, LASER ETCHED, OR EMBOSSED OR OF A TYPE THAT ONCE APPLIED CANNOT BE REMOVED WITHOUT BEING DESTROYED. THE IDENTIFICATION IS TO BE VISIBLE AFTER INSTALLATION. 2.01 SUBMIT THE FOLLOWING: 1. PRODUCT DATA. 2. SHOP DRAWINGS SHOWING SIZE AND LOCATION OF EACH INSTALLATION. 2.02 PRODUCT SPECIFICATIONS ARE AS FOLLOWS: 1. (GL-01)TYPE 1: 3/8" CLEAR FLOAT GLASS. COMPLY WITH ASTM C1036, TYPE I (TRANSPARENT GLASS, FLAT), CLASS 1 (CLEAR), QUALITY Q3 (GLAZING SELECT). PROCESSED TO COMPLY WITH ASTM C1048, KIND FT (FULLY TEMPERED). SEE DOOR & FINISH SCHEDULE FOR SPECS/THICKNESS. 2. (GL-02) TYPE 2: 1/2" CLEAR FLOAT GLASS (TEMPERED AS REQUIRED BY ANSI, LOCAL CODES AND ORDINANCES). 2.03 MIRRORS: 1/4 INCH POLISHED PLATE GLASS SLIVER COATED AND HERMETICALLY SEALED WITH A UNIFORM COATING OF ELECTROLYTIC COPPER PLATING. REFER PLANS FOR NOTES 2.04 GLAZING SEALANTS: AS RECOMMENDED BY FGMA SUITABLE FOR APPLICATION AND CONDITIONS INDICATED. 2.05 GLAZING SEALANT: G.E. "SILICONE CONSTRUCTION 1200 SEALANT" OR APPROVED EQUAL, CONFORMING TO FS TT-S-00230 IN COLOR SELECTED BY DESIGNER. 2.06 GASKETS, SETTING BLOCKS AND SPACERS: G.E. TYPE II PRE FORMED SILICONE RUBBER, OF ASTM D2240 SHORE "A" DUROMETER HARDNESS WITHIN THE RANGES SPECIFIED BELOW TO SUIT THE SPECIFIC INSTALLATION CONDITIONS. SEE ELEVATIONS AND DETAILS FOR SPECIFIC PRODUCT. 2.07 GLAZING TAPE: AS RECOMMENDED BY SEALANT MANUFACTURER FOR THE SPECIFIC INSTALLATION CONDITIONS. 2.08 FABRICATE GLASS WITH SMOOTH, STRAIGHT EDGES TO FULL SIZE REQUIRED TO OBTAIN BEARING ALONG ENTIRE WIDTH OF LITE. FABRICATE INSULATING GLASS UNITS USING BOTH PRIMARY AND SECONDARY SEALS AND AS OTHERWISE REQUIRED TO COMPLY WITH THE IGCC CBA CLASSIFICATION. INSTALL FACTORY LABEL ON EACH PANE OF GLASS. 3.01 SIZE GLASS FOR EACH OPENING WITHIN TOLERANCES AND DIMENSIONS ESTABLISHED BY FIELD MEASUREMENTS. 3.02 INSTALL GLASS TO BE WATERTIGHT AND AIRTIGHT. COMPLY WITH FGMA "GLAZING MANUAL" EXCEPT AS OTHERWISE INDICATED, SPECIFIED OR RECOMMENDED BY THE MANUFACTURERS OF THE GLASS, GLAZING MATERIALS AND FRAMES. 3.03 SET GLASS IN LOOSE STOPS AS DETAILED. SET STOPS IN SEALANT.WHERE JOINTS OCCUR IN BUTT GLAZED CONDITIONS FILL JOINT WITH CLEAR SILICONE SEALANT. JOINT TO BE 1/8" WIDE UNLESS NOTED OTHERWISE. SECTION 088000 -GLAZING 1.01 FURNISH AND INSTALL 1/2" TEMPERED GLASS DOORS AND FIXED PANELS. PROVIDE CONTINUOUS TOP AND BOTTOM RAILS OR PATCHES AS INDICATED IN DRAWINGS. FINISH BY MFG. AS NOTED IN DOOR SCHEDULE. 1.02 PROVIDE SIZE AND PROFILES INDICATED ON APPROVED SHOP DRAWINGS. PROVIDE STRAIGHT, SHARPLY DEFINED LINES AND AREAS. 1.03 PROVIDE RAIL SECTIONS FABRICATED FROM EXTRUDED ALUMINUM ALLOY AND TEMPERED AS RECOMMENDED BY MANUFACTURER FOR STRENGTH CORROSION RESISTANCE, AND SPECIFIED FINISH, BUT NOT LESS THAN 27,000 PSI ULTIMATE STRENGTH, AND NOT LESS THAN 0.125 IN. THICKNESS AT ANY LOCATION. 2.01 TOP EDGE OF BOTTOM RAIL SHALL INCLUDE SLOPE TO MEET LOCAL CODE AND ADA REQUIREMENTS. 2.02 PROVIDE 1/2" INCH THICK CLEAR, TEMPERED GLASS, WITH POLISHED-FINISH RADIUSED ("PENCILED") EDGES. 2.03 SAFETY GLASS PANELS TO CONFORM TO REQUIREMENTS OF ANSI Z29.1. 2.04 SUBMIT SHOP DRAWINGS SHOWING FULL SIZE DETAILS, SECTIONS, SIZES, REINFORCEMENT, GLAZING, AND RELATIONSHIP TO WORK OF THIS SECTION. INCLUDE INFORMATION ON FABRICATION, INSTALLATION, GLAZING, AND OTHER INFORMATION REQUIRED FOR COMPLETE DESCRIPTION OF WORK. 2.05DOOR CLOSERS AT ALL 1/2" THICK TEMPERED GLASS DOORS SHALL BE OVERHEAD CONCEALED TYPE DOOR CLOSERS UNLESS NOTED OTHERWISE, FURNISH AND INSTALL HEAVY DUTY CONCEALED DOOR CLOSER ALONG WITH THE NECESSARY INSTALLATION ACCESSORIES. SELECT ACTION APPROPRIATE TO LOCATION. SECTION 088010 -TEMPERED GLASS DOORS 1.01 ACTION SUBMITTALS A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT. B. SHOP DRAWINGS: INCLUDE MIRROR ELEVATIONS, EDGE DETAILS, MIRROR HARDWARE, AND ATTACHMENT DETAILS. 1.02 SPECIAL WARRANTY: MANUFACTURER AGREES TO REPLACE MIRRORS THAT DETERIORATE WITHIN SPECIFIED WARRANTY PERIOD. DETERIORATION OF MIRRORS IS DEFINED AS DEFECTS DEVELOPED FROM NORMAL USE THAT ARE NOT ATTRIBUTED TO MIRROR BREAKAGE OR TO MAINTAINING AND CLEANING MIRRORS CONTRARY TO MANUFACTURER'S WRITTEN INSTRUCTIONS. DEFECTS INCLUDE DISCOLORATION, BLACK SPOTS, AND CLOUDING OF THE SILVER FILM. WARRANTY PERIOD: FIVE YEARS FROM DATE OF SUBSTANTIAL COMPLETION. 2.01 SILVERED FLAT GLASS MIRRORS A. MIRRORS, GENERAL: ASTM C1503;MANUFACTURED USING COPPER-FREE, LOW-LEAD MIRROR COATING PROCESS. B. TEMPERED GLASS MIRRORS: MIRROR GLAZING QUALITY FOR BLEMISH REQUIREMENTS AND COMPLYING WITH ASTM C1048 FOR KIND FT, CONDITION A, TEMPERED FLOAT GLASS BEFORE SILVER COATING IS APPLIED. 1. NOMINAL THICKNESS: 6.0 MM. 2.02 MISCELLANEOUS MATERIALS A. SETTING BLOCKS: ELASTOMERIC MATERIAL WITH A SHORE, TYPE A DUROMETER HARDNESS OF 85, PLUS OR MINUS 5. B. EDGE SEALER: COATING APPROVED BY MIRROR MANUFACTURER. C. MIRROR MASTIC: AN ADHESIVE SETTING COMPOUND, ASBESTOS-FREE, PRODUCED SPECIFICALLY FOR SETTING MIRRORS. D. FILM BACKING FOR SAFETY MIRRORS: FILM BACKING AND PRESSURE-SENSITIVE ADHESIVE; BOTH COMPATIBLE WITH MIRROR BACKING PAINT AS CERTIFIED BY MIRROR MANUFACTURER. 2.03 FABRICATION A. FABRICATE CUTOUTS FOR NOTCHES AND HOLES IN MIRRORS WITHOUT MARRING VISIBLE SURFACES. LOCATE AND SIZE CUTOUTS SO THEY FIT CLOSELY AROUND PENETRATIONS IN MIRRORS. B. MIRROR EDGE TREATMENT: FLAT POLISHED. SEAL EDGES OF MIRRORS WITH EDGE SEALER. 3.01 EXAMINATION A. EXAMINE SUBSTRATES, OVER WHICH MIRRORS ARE TO BE MOUNTED, WITH INSTALLER PRESENT, FOR COMPLIANCE WITH INSTALLATION TOLERANCES, SUBSTRATE PREPARATION, AND OTHER CONDITIONS AFFECTING PERFORMANCE OF THE WORK. B. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED AND SURFACES ARE DRY. 3.02 PREPARATION A. COMPLY WITH MASTIC MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS FOR PREPARATION OF SUBSTRATES, INCLUDING COATING SUBSTRATES WITH MASTIC MANUFACTURER'S SPECIAL BOND COATING WHERE APPLICABLE. 3.03 INSTALLATION A. GENERAL: INSTALL MIRRORS TO COMPLY WITH MIRROR MANUFACTURER'S WRITTEN INSTRUCTIONS AND WITH REFERENCED GANA PUBLICATIONS. MOUNT MIRRORS ACCURATELY IN PLACE IN A MANNER THAT AVOIDS DISTORTING REFLECTED IMAGES. B. INSTALL MIRRORS WITH MASTIC. ATTACH MIRROR SECURELY TO MOUNTING SURFACES WITH MECHANICAL FASTENERS INSTALLED WITH ANCHORS OR INSERTS AS APPLICABLE. INSTALL FASTENERS SO HEADS DO NOT IMPOSE POINT LOADS ON BACKS OF MIRRORS. 1. APPLY MASTIC TO COMPLY WITH MASTIC MANUFACTURER'S WRITTEN INSTRUCTIONS FOR COVERAGE AND TO ALLOW AIR CIRCULATION BETWEEN BACK OF MIRRORS AND FACE OF MOUNTING SURFACE. C. CLEAN EXPOSED SURFACE OF MIRRORS NOT MORE THAN FOUR DAYS BEFORE DATE SCHEDULED FOR INSPECTIONS THAT ESTABLISH DATE OF SUBSTANTIAL COMPLETION. CLEAN MIRRORS AS RECOMMENDED IN WRITING BY MIRROR MANUFACTURER. D. REFER PLANS FOR ADDITIONAL NOTES SECTION 088300 -MIRRORS 1.01 FURNISH AND INSTALL FILM PER MANUFACTURER'S INSTRUCTIONS AND EXTENTS IDENTIFIED WITHIN THE DOCUMENTS. 1.02 SUBMITTALS: SUBMIT PRODUCT DATA AND SAMPLES. 2.00 PRODUCTS: GLAZING FILM (GF) -SEE FINISH SCHEDULE FOR SPECIFICATIONS. SEE ELEVATIONS/DOOR SCHEDULE FOR LOCATIONS SECTION 089700 -GLAZING SURFACE FILMS 1.01 COMPLY WITH THE FOLLOWING GENERAL STANDARDS: A. ASTM C645, C754 AND GA-216 FOR SPECIFICATION AND INSTALLATION OF STEEL FRAMING MEMBERS B. ASTM C36 FOR GYPSUM WALLBOARD C. ASTM C840-01 FOR APPLICATION AND FINISHING OF GYPSUM BOARD. WALL TOLERANCES: MAXIMUM VARIATION FROM FLATNESS -1/8 INCH IN 10 FEET IN ANY DIRECTION D. ASTM C79 FOR GYPSUM SHEATHING E. ASTM C630 FOR WATER RESISTANT GYPSUM BOARD (MR) 1.02 COORDINATE INSTALLATION AND WALL LAYOUT WITH ELECTRICAL AND MECHANICAL WORK. PROVIDE BLOCKING AND BACKING AS REQUIRED. COORDINATE FIRE STOPPING APPLICATION. 2.01 WALL TEXTURE TO HAVE SMOOTH SURFACE AFTER TAPE & BED AND READY TO RECEIVE NEW FINISHES AS SPECIFIED IN FINISH SCHEDULE. PROVIDE LEVEL 4 FINISH UNLESS OTHERWISE NOTED. 2.02 PROVIDE METAL CORNER BEADS AT VERTICAL AND HORIZONTAL EXTERIOR CORNERS AND METAL J TRIM OR L TRIM AT EXPOSED EDGE CONDITIONS. 2.03 SUBMIT THE FOLLOWING: 1. PRODUCT DATA ON METAL FRAMING, GYPSUM BOARD, JOINT TAPE. 2. TWO (2) 12" X 12" OF EACH GYPSUM BOARD FINISH TEXTURE. 3. MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR EACH PRODUCT PROPOSED FOR USE SECTION 092100 -GYPSUM BOARD ASSEMBLIES 2.04 PROVIDE DRYWALL ACCESSORIES AS DETAILED ON DRAWINGS. 1. CASING BEADS:USG 200-B METAL TRIM OR EQUAL. 2. CORNER BEADS:USG DURABEAD REINFORCED. 3. EXPANSION JOINTS:BREAK METAL AS INDICATED. 3.01 PROVIDE WALL/CEILING FRAMING SYSTEMS AS SHOWN ON PLANS. SELECT STUD GAUGE BASE ON HEIGHT/SPAN RATIOS RECOMMENDED BY MANUFACTURER. INSTALL FASTENERS NO GREATER THAN 24 INCHES O.C. OR AS REQUIRED BY CODE. 3.02 DOUBLE STUD JAMBS AT OPENINGS. 3.03 SPLICE FLOOR AND CEILING TRACK FOR PROPER ALIGNMENT. 3.04 FURNISH AND INSTALL BLOCKING REQUIRED FOR DOORS, HARDWARE, ACCESSORIES, CABINETRY, ETC. SHOWN ON PLANS. COORDINATE LOCATION OF MECHANICAL/ELECTRICAL AND PLUMBING ASSEMBLIES WITHIN WALL ASSEMBLY. 3.05 INSTALL MULTIPLE LAYERS OF GYPSUM BOARD PERPENDICULAR TO EACH OTHER. 3.06 PROVIDE SLIP JOINT CONNECTION AT UNDERSIDE OF DECK FOR UNINTERRUPTED PARTITIONS INSTALLED FLOOR TO DECK. 3.07 PROVIDE LATERAL WALL BRACING WHERE NECESSARY FOR A RIGID, STABLE INSTALLATION. 3.08 CEILING FRAMING SHALL BE INSTALLED INDEPENDENT OF WALLS, COLUMNS, AND ABOVE CEILING WORK. COORDINATE LOCATION OF HANGER WIRE WITH OTHER TRADES. INSTALL RC CHANNELS 24 INCHES O.C. MAXIMUM IN STRICT ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS. 3.09 INSTALL NON-HARDENING/NON-SKINNING ACOUSTICAL SEALANT IN WALLS DESIGNED FOR ACOUSTICAL ATTENUATION PER MANUFACTURER'S REQUIREMENTS. INSTALL ACOUSTICAL INSULATION (FS HH I 521, PRE- FORMED MINERAL WOOL FRICTION FIT WITHOUT VAPOR BARRIER) TIGHT WITHIN SPACES, BEHIND AND AROUND ELECTRICAL AND MECHANICAL ITEMS AND TIGHT TO ITEMS PASSING THROUGH WALL ASSEMBLY. 3.10 FIRE CAULK AROUND PENETRATIONS IN FIRE AND ACOUSTICAL ASSEMBLIES. 1.01 SECTION INCLUDES: 1. NON-LOAD-BEARING STEEL FRAMING SYSTEMS FOR INTERIOR GYPSUM BOARD ASSEMBLIES. 2.01 PERFORMANCE REQUIREMENTS A. FIRE-TEST-RESPONSE CHARACTERISTICS: PROVIDE MATERIALS AND CONSTRUCTION IDENTICAL TO THOSE TESTED ACCORDING TO ASTM E 119. B. STC-RATED ASSEMBLIES: PROVIDE MATERIALS AND CONSTRUCTION IDENTICAL TO THOSE TESTED IN ASSEMBLY INDICATED ACCORDING TO ASTM E 90 AND CLASSIFIED ACCORDING TO ASTM E 413. 2.02 FRAMING SYSTEMS A. STEEL STUDS AND RUNNERS: ASTM C 645.USE EITHER STEEL STUDS AND RUNNERS OR DIMPLED STEEL STUDS AND RUNNERS. 1. MINIMUM BASE-METAL THICKNESS:0.033 INCH (0.84 MM). 2. DEPTH: AS INDICATED ON DRAWINGS. B. SLIP-TYPE HEAD JOINTS: WHERE INDICATED, PROVIDE THE FOLLOWING IN THICKNESS NOT LESS THAN INDICATED FOR STUDS AND IN WIDTH TO ACCOMMODATE DEPTH OF STUDS: 1. SINGLE LONG-LEG RUNNER SYSTEM: ASTM C 645 TOP RUNNER WITH 2-INCH-(51-MM-) DEEP FLANGES, INSTALLED WITH STUDS FRICTION FIT INTO TOP RUNNER AND WITH CONTINUOUS BRIDGING LOCATED WITHIN 12 INCHES (305 MM) OF THE TOP OF STUDS TO PROVIDE LATERAL BRACING. C. FLAT STRAP AND BACKING PLATE: STEEL SHEET FOR BLOCKING AND BRACING IN LENGTH AND WIDTH INDICATED. 1. MINIMUM BASE-METAL THICKNESS: 0.033 INCH (0.84 MM) . D. COLD-ROLLED CHANNEL BRIDGING: STEEL, 0.053-INCH (1.34-MM) MINIMUM BASE-METAL THICKNESS, WITH MINIMUM 1/2-INCH-(13-MM-) WIDE FLANGES. 1. DEPTH: 1-1/2 INCHES (38 MM). 2. CLIP ANGLE: NOT LESS THAN 1-1/2 BY 1-1/2 INCHES (38 BY 38 MM), 0.068-INCH-(1.72-MM-) THICK, GALVANIZED STEEL. E. FASTENERS FOR METAL FRAMING: OF TYPE, MATERIAL, SIZE, CORROSION RESISTANCE, HOLDING POWER, AND OTHER PROPERTIES REQUIRED TO FASTEN STEEL MEMBERS TO SUBSTRATES. 3.01 INSTALLATION, GENERAL A. INSTALLATION STANDARD: ASTM C 754. 1. GYPSUM BOARD ASSEMBLIES: ALSO COMPLY WITH REQUIREMENTS IN ASTM C 840 THAT APPLY TO FRAMING INSTALLATION. B. INSTALL SUPPLEMENTARY FRAMING, AND BLOCKING TO SUPPORT FIXTURES, EQUIPMENT SERVICES, HEAVY TRIM, GRAB BARS, TOILET ACCESSORIES, FURNISHINGS,OR SIMILAR CONSTRUCTION. C. INSTALL BRACING AT TERMINATIONS IN ASSEMBLIES. D. DO NOT BRIDGE BUILDING CONTROL AND EXPANSION JOINTS WITH NON-LOAD-BEARING STEEL FRAMING MEMBERS. FRAME BOTH SIDES OF JOINTS INDEPENDENTLY. 3.02 INSTALLING FRAMED ASSEMBLIES A. INSTALL FRAMING SYSTEM COMPONENTS ACCORDING TO SPACINGS INDICATED, BUT NOT GREATER THAN SPACINGS REQUIRED BY REFERENCED INSTALLATION STANDARDS FOR ASSEMBLY TYPES. B. WHERE STUDS ARE INSTALLED DIRECTLY AGAINST EXTERIOR MASONRY WALLS OR DISSIMILAR METALS AT EXTERIOR WALLS, INSTALL ISOLATION STRIP BETWEEN STUDS AND EXTERIOR WALL. C. INSTALL STUDS SO FLANGES WITHIN FRAMING SYSTEM POINT IN SAME DIRECTION. D. INSTALL TRACKS (RUNNERS) AT FLOORS AND OVERHEAD SUPPORTS. EXTEND FRAMING FULL HEIGHT TO STRUCTURAL SUPPORTS OR SUBSTRATES ABOVE SUSPENDED CEILINGS, EXCEPT WHERE PARTITIONS ARE INDICATED TO TERMINATE AT SUSPENDED CEILINGS. CONTINUE FRAMING AROUND DUCTS PENETRATING PARTITIONS ABOVE CEILING. 1. SLIP-TYPE HEAD JOINTS: WHERE FRAMING EXTENDS TO OVERHEAD STRUCTURAL SUPPORTS, INSTALL TO PRODUCE JOINTS AT TOPS OF FRAMING SYSTEMS THAT PREVENT AXIAL LOADING OF FINISHED ASSEMBLIES. 2. DOOR OPENINGS: SCREW VERTICAL STUDS AT JAMBS TO JAMB ANCHOR CLIPS ON DOOR FRAMES; INSTALL RUNNER TRACK SECTION (FOR CRIPPLE STUDS) AT HEAD AND SECURE TO JAMB STUDS. A. INSTALL TWO STUDS AT EACH JAMB UNLESS OTHERWISE INDICATED. B. INSTALL CRIPPLE STUDS AT HEAD ADJACENT TO EACH JAMB STUD, WITH A MINIMUM 1/2-INCH (13-MM) CLEARANCE FROM JAMB STUD TO ALLOW FOR INSTALLATION OF CONTROL JOINT IN FINISHED ASSEMBLY. C. EXTEND JAMB STUDS THROUGH SUSPENDED CEILINGS AND ATTACH TO UNDERSIDE OF OVERHEAD STRUCTURE. 3. OTHER FRAMED OPENINGS: FRAME OPENINGS OTHER THAN DOOR OPENINGS THE SAME AS REQUIRED FOR DOOR OPENINGS UNLESS OTHERWISE INDICATED. INSTALL FRAMING BELOW SILLS OF OPENINGS TO MATCH FRAMING REQUIRED ABOVE DOOR HEADS. 4. SOUND-RATED PARTITIONS: INSTALL FRAMING TO COMPLY WITH SOUND-RATED ASSEMBLY INDICATED. 5. CURVED PARTITIONS: A. BEND TRACK TO UNIFORM CURVE AND LOCATE STRAIGHT LENGTHS SO THEY ARE TANGENT TO ARCS. B. BEGIN AND END EACH ARC WITH A STUD, AND SPACE INTERMEDIATE STUDS EQUALLY ALONG A ARCS. ON STRAIGHT LENGTHS OF NO FEWER THAN TWO STUDS AT ENDS OF ARCS, PLACE STUDS 6 INCHES (150 MM) O.C. E. INSTALLATION TOLERANCE: INSTALL EACH FRAMING MEMBER SO FASTENING SURFACES VARY NOT MORE THAN 1/8 INCH (3 MM) FROM THE PLANE FORMED BY FACES OF ADJACENT FRAMING. SECTION 092216 -NON-STRUCTURAL METAL FRAMING 1.01 REFERENCES: A. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) A108.1 THROUGH .10 -SPECIFICATIONS FOR VARIOUS CERAMIC TILE AND QUARRY TILE MATERIALS AND INSTALLATION. B. ANSI A118.4 -SPECIFICATION FOR DRY SET LATEX PORTLAND CEMENT MORTAR. C. ANSI A136.1 -ORGANIC ADHESIVES FOR INSTALLATION OF CERAMIC TILE, TYPE 1 AND TYPE 2. D. ANSI A137.1 -SPECIFICATION FOR CERAMIC TILE. E. THE COUNCIL OF NORTH OF AMERICA FOR CERAMIC TILE INSTALLATION. 1.02 SUBMITTALS: A. SHOP DRAWINGS: SHOP DRAWINGS SHOWING SIZE AND TYPE OF EACH PRODUCT SPECIFIED; INCLUDING QUARRY TILE, PORCELAIN TILE, CERAMIC TILE LAYOUT, SPECIAL DETAILS, SPECIAL INSTALLATION REQUIREMENTS, AND SPECIAL SHAPES. B. SAMPLES: 1. SUBMIT PRODUCT DATA AND MATERIAL SAMPLES FOR EACH TYPE. SUBMIT SAMPLES OF SUFFICIENT SIZE TO INDICATE TRUE RANGE OF COLOR AND TEXTURE. A. ONE (1) FULL SIZE TILE OF EACH CERAMIC / PORCELAIN TILE WITH TWO COATS OF SEALER AS SPECIFIED B. SUBMIT TWO (2) SAMPLES OF ALL GROUT COLORS AS INDICATED ON FINISH PLANS AND FULL RANGE OF MANUFACTURERS STANDARD GROUT COLORS C. PROVIDE GROUTED TILE MOCK-UP(S) DEMONSTRATING SPECIFIED GROUT COLOR(S) AND GROUT WIDTH. IF MORE THAN ONE GROUT CONDITION IS SPECIFIED, MOCK-UP(S) SHOULD DEMONSTRATE EACH CONDITION. COORDINATE WITH ARCHITECT ACTUAL MOCK-UP REQUIREMENTS. 1.03 DELIVERY, STORAGE AND HANDLING: A. DELIVER AND STORE SETTING AND GROUT MATERIALS IN ORIGINAL CONTAINERS WITH SEALS UNBROKEN AND LABELS INTACT. B. FACTORY PACKAGE TILE AND MARBLE TO PROVIDE PROTECTION FROM DAMAGE AND EXPOSURE TO ELEMENTS. 1.04 SITE CONDITIONS: A. MAINTAIN TEMPERATURE OF AREAS TO BE TILED AT 50 DEGREES F MINIMUM AND 95 DEGREES F MAXIMUM DURING TILE WORK AND 7 DAYS AFTER COMPLETION. B. PROVIDE ADEQUATE VENTILATION WHEN USING ADHESIVES. C. PROVIDE LIGHTING DURING INSTALLATION THAT IS SIMILAR TO FINAL LIGHTING IN LOCATION AND INTENSITY. 2.01 PRODUCTS: A. CERAMIC TILE (T): SEE FINISH SCHEDULE FOR SPECIFICATIONS B. PORCELAIN TILE (T): SEE FINISH SCHEDULE FOR SPECIFICATIONS C. QUARRY TILE (T): SEE FINISH SCHEDULE FOR SPECIFICATIONS D. TILE BASE (B): SEE FINISH SCHEDULE FOR SPECIFICATIONS 2.02 ACCESSORY MATERIALS A. THRESHOLDS: FABRICATE TO PROVIDE TRANSITION BETWEEN ADJACENT FLOOR FINISHES. BEVEL EDGES AT 1:2 SLOPE, LIMIT HEIGHT OF BEVEL TO 1/2 INCH (12.7 MM) OR LESS, AND FINISH BEVEL TO MATCH FACE OF THRESHOLD. B. WATERPROOFING AND CRACK-SUPPRESSION MEMBRANES FOR THIN-SET TILE INSTALLATIONS: MANUFACTURER'S STANDARD PRODUCT THAT COMPLIES WITH ANSI A118.10,SELECTED FROM THE FOLLOWING. 1. FABRIC-REINFORCED, FLUID-APPLIED PRODUCT: LIQUID-LATEX RUBBER,WITH A VOC CONTENT OF 65 G/L OR LESS WHEN CALCULATED ACCORDING TO 40 CFR59, SUBPART D (EPA METHOD 24), WITH FABRIC REINFORCEMENT. a. AVAILABLE PRODUCTS: 1. CUSTOM BUILDING PRODUCTS; TROWEL & SEAL WATERPROOFING AND ANTI-FRACTURE MEMBRANE. 2. LATICRETE INTERNATIONAL INC.; LATICRETE 9235 WATERPROOF MEMBRANE. 3. MAPEI CORPORATION; PRP M19. 4. SUMMITVILLE TILES, INC.; S-9000. 2. LATEX-PORTLAND CEMENT PRODUCT: FLEXIBLE MORTAR WITH ACRYLIC-LATEX ADDITIVE. a. AVAILABLE PRODUCTS: 1. BOIARDI PRODUCTS CORPORATION; ELASTIMENT 323. 2. MAPEI CORPORATION; PRP 315. 3. SOUTHERN GROUTS & MORTARS, INC.; SOUTHCRETE 1100. 4. TEC SPECIALTY PRODUCTS INC.; TA-324, TRIPLE FLEX. 2.03 SETTING AND GROUTING MATERIALS A. ORGANIC ADHESIVE: ANSI A136.1, TYPE I. 1. PRODUCTS: a. B-4050 MULTI-PURPOSE ADHESIVE; PROSPEC BONSAL AMERICAN. WWW.PROSPEC.COM b. HYDROMENT 7001 TILE MASTIC; BOSTIK FINDLEY, INC. WWW.BOSTIK-US.COM c. PERMABOND ULTRA 1002; C-CURE. WWW.C-CURE.COM d. DAP® WELDWOOD® MULTI-PURPOSE CERAMIC TILE ADHESIVE; DAP, INC. WWW.DAP.COM e. MASTIK 440; JAMO INC. WWW.JAMOINC.COM f. LATICRETE 15 PREMIUM MULTI-MASTIC ADHESIVE; LATICRETE INTERNATIONAL INC. WWW.LATICRETE.COM g. ULTRAMASTIC ECO; MAPEI CORPORATION. WWW.MAPEI.COM h. MULTI-PURPOSE MASTIC TYPE I; SOUTHERN GROUTS & MORTARS, INC. WWW.SGM.COM i. DOUBLE DUTY™ PREMIUM ADHESIVE FOR CERAMIC TILE; TEC SPECIALTY PRODUCTS INC. WWW.TECSPECIALTY.COM B. ADHESIVE: ANSI 118.3 MORTAR 1. PRODUCTS: a. EPOXY INC; EPOXYEZCLEAN b. CUSTOM BUILDING PRODUCTS; EMB-LITE PREMIUM EPOXY BONDING MORTAR c. LATICRETE SUPERCAP, LLC; SPECTRALOCK PRO d. MAPEI CORPORATION KERAPOXY 2. ADHESIVES SHALL HAVE A VOC CONTENT OF 65 G/L OR LESS. C. POLYMER-MODIFIED TILE GROUT: ANSI A118.7 1. POLYMER TYPE: EITHER ETHYLENE VINYL ACETATE, IN DRY, REDISPERSIBLE FORM, PREPACKAGED WITH OTHER DRY INGREDIENTS, OR ACRYLIC RESIN OR STYRENE-BUTADIENE RUBBER IN LIQUID-LATEX FORM FOR ADDITION TO PREPACKAGED DRY-GROUT MIX. a. UNSANDED GROUT MIXTURE FOR JOINTS 1/8 INCH (3.2 MM) AND NARROWER. b. SANDED GROUT MIXTURE FOR JOINTS 1/8 INCH AND WIDER SECTION 093000 -TILING 3.03 INSTALLATION A. COMPLY WITH PARTS OF ANSI A108 SERIES OF TILE INSTALLATION STANDARDS IN "SPECIFICATIONS OF THE INSTALLATION OF CERAMIC TILE" THAT APPLY TO TYPES OF SETTING AND GROUTING MATERIALS AND TO THE METHODS INDICATED. INSTALLATION METHOD SHALL BE DRY-SET MORTER METHOD CONFORMING TO ANSI A118.1 1. SET, GROUT, CLEAN, PROTECT AND CURE CERAMIC AND QUARRY TILE IN ACCORDANCE WITH APPLICABLE ANSI SPECIFICATION A108 AND TCNA. 2. SET TILE TRUE TO LINE AND DIMENSION. 3. LAY OUT TILE SO NO LESS THAN HALF TILE OCCURS. 4. PROVIDE JOINTS OF UNIFORM WIDTH AND ALIGNMENT IN BOTH DIRECTIONS FOR TILE AND TRIM. 5. CUT AND FIT TILE CAREFULLY AGAINST TRIM AND ACCESSORIES. 6. FIT AROUND PIPES, ELECTRICAL BOXES AND OTHER BUILT-IN FIXTURES SO ESCHUTEONS, PLATES AND COLLARS WILL COMPLETELY OVERLAP CUT EDGES. B. COMPLY WITH TCA'S "HANDBOOK FOR CERAMIC TILE INSTALLATION". C. AT ALL TILE EXPOSED TO DIRECT SUNLIGHT, PROVIDE CONTROL JOINTS AT 12" O.C. MAXIMUM IN EACH DIRECTION. PROVIDE CONTROL JOINTS IN TILE WORK NOT EXPOSED TO DIRECT SUNLIGHT AT 24" O.C. MAXIMUM. PROVIDE CONTROLS JOINTS AT ALL LOCATIONS WHERE TILE WORK ABUTS RESTRAINING SURFACES SUCH AS PERIMETER WALL, DISSIMILAR FLOORS, CURBS, COLUMNS, PIPES AND WHERE CHANGES OCCUR IN BACKING MATERIALS. D. GROUT 1. MIX AND APPLY IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTRUCTIONS. FORCE GROUTS INTO JOINTS COMPLETELY FILLING JOINTS. E. APPLY SEALER TO CERAMIC TILE FLOORING ACCORDING TO SEALER MANUFACTURE'S WRITTEN INSTRUCTIONS. 1. SEAL GROUT FOR ALL BATHROOMS. 3.04 CERAMIC TILE SEALER TO MEET THE FOLLOWING MINIMUM VOC LIMIT REQUIREMENTS: SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE 1113. A. PRIMERS, SEALERS AND UNDERCOATERS -200G/L 3.05 CERAMIC TILE ADHESIVES TO MEET THE FOLLOWING MINIMUM VOC LIMIT REQUIREMENTS: SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE 1168. A. CERAMIC TILE INSTALLATION -65 G/L SECTION 093000 -TILING 1.01 DO NOT INSTALL PANEL CEILING UNTIL BUILDING AREAS ARE ENCLOSED, SUFFICIENT HEAT IS PROVIDED, DUST GENERATING ACTIVITIES HAVE TERMINATED AND OVERHEAD MECHANICAL WORK IS COMPLETED, TESTED AND APPROVED AND SYSTEM IS OPERATIONAL AND BUILDING TEMPERATURE ACCLIMATED. 1.02 PERMIT WET WORK TO DRY PRIOR TO COMMENCEMENT OF INSTALLATION. MAINTAIN UNIFORM TEMPERATURES OF MINIMUM 65 DEGREES F AND HUMIDITY OF 20% TO 40% PRIOR TO, DURING AND AFTER INSTALLATION. 1.03 WARRANTY: 10 YEAR MANUFACTURER'S LIMITED WARRANTY AGAINST SAGGING, WARPING, OR SHRINKING. 2.01 COMPLY WITH ASTM C635, AS APPLICABLE TO TYPE OF SUSPENSION SYSTEM REQUIRED FOR CEILING UNITS INDICATED. COORDINATE WITH OTHER WORK SUPPORTED BY OR PENETRATING THROUGH CEILINGS, INCLUDING LIGHT FIXTURES AND MECHANICAL EQUIPMENT. 2.02 WALL MOLDINGS: SAME MANUFACTURER AS SYSTEM COMPONENTS. COLD-ROLLED STEEL, FINISH TO MATCH SYSTEM COMPONENTS. 2.03 PRODUCTS (ACP): -SEE REFLECTED CEILING PLAN & FINISH SCHEDULE FOR SPECIFICATIONS 2.04 SUBMIT THE FOLLOWING: 1. SUBMIT PRODUCT DATA 3.01 AVOID USE OF LESS THAN HALF WIDTHS AT BORDERS, REFER TO REFLECTED CEILING PLANS FOR LAYOUT OF CEILING AREA, NOTIFY DESIGNER IF SITE CONDITIONS VARY FROM DRAWINGS. 3.02 CONSULT MECHANICAL AND ELECTRICAL DRAWINGS FOR TYPE AND EXTENT OF THEIR WORK BECOMING PART OF OR PENETRATING CEILING. 3.03 INSTALL CEILINGS LEVEL, TRUE, AND PLUMB. INSTALL MATERIALS IN ACCORDANCE WITH MANUFACTURER'S PRINTED INSTRUCTIONS, COMPLY WITH GOVERNING REGULATIONS, AND INDUSTRY STANDARDS APPLICABLE TO WORK. INSTALL SUSPENSION SYSTEM TO COMPLY WITH ASTM C636, WITH HANGERS SUPPORTED FROM BUILDING STRUCTURAL MEMBERS. LOCATE HANGERS NEAR EACH END AND SPACED 4'-0" ALONG DIRECT HUNG RUNNERS, UNLESS OTHERWISE INDICATED. 3.04 SECURE WIRE HANGERS BY LOOPING AND WIRE-TYING, EITHER DIRECTLY TO STRUCTURES OR TO INSERTS, EYE-SCREWS OR OTHER DEVICES WHICH ARE SECURE AND APPROPRIATE FOR SUBSTRATE, AND WHICH WILL NOT DETERIORATE OR FAIL WITH AGE OR ELEVATED TEMPERATURES. 3.05 INSTALL EDGE MOLDINGS AT INTERSECTION OF CEILING AND VERTICAL SURFACES, USING MAXIMUM LENGTHS, STRAIGHT, TRUE TO LINE AND LEVEL. MITER CORNERS. PROVIDE EDGE MOLDINGS AT JUNCTIONS WITH OTHER CEILING FINISHES. WHERE BULL NOSE OR CURVED CORNERS OCCUR, PROVIDE PRE-FORMED CLOSERS TO MATCH EDGE MOLDING. 3.06 FIT LAY-IN PANELS IN PLACE, FREE FROM DAMAGED EDGES OR OTHER DEFECTS DETRIMENTAL TO APPEARANCE AND FUNCTION. FIT BORDER UNITS NEATLY AGAINST ABUTTING SURFACES. INSTALL LAY-IN PANELS LEVEL, IN UNIFORM PLANE AND FREE FROM TWIST, WARP AND DENTS. SCRIBE AND CUT UNITS TO FIT ACCURATELY AT PENETRATIONS AND EDGES REQUIRING CUT UNITS. 3.07 INSTALL GRID SYSTEM IN ACCORDANCE WITH ASTM C635. 3.08 INSTALL ACOUSTICAL TILE PER MANUFACTURER'S INSTRUCTIONS. VARIATION FROM FLAT AND LEVEL SURFACE SHALL BE 1/8" IN 10'-0" MAX. 3.09 PROVIDE ATTIC STOCK OF ONE CARTON OF ACOUSTIC TILE PER 10,000 SF. SECTION 095100 -ACOUSTIC CEILINGS 1.01 PROVIDE EXTRA TILE AT THE RATE OF ONE CARTON PER 500 SQUARE FEET, FOR EACH COLOR USED ON THE PROJECT; AND A 10 FOOT MINIMUM SECTION OF RUBBER BASE, PLUS SCRAPS OF SUITABLE SIZE FOR USE IN REPLACEMENT. PROVIDE AN EXTRA TWO LINEAL YARDS OF SHEET VINYL AND SCRAPS OF USABLE SIZE. 1.02 WARRANTY: PROVIDE MANUFACTURER'S STANDARD 5 YEAR WARRANTY. 2.01 PRODUCTS: A. RESILIENT FLOORING (RF) -SEE FINISH SCHEDULE FOR SPECIFICATIONS 2.02 ADHESIVE: MOISTURE RESISTANT TYPE AS RECOMMENDED BY RESILIENT FLOORING MANUFACTURER FOR TYPE OF FLOORING AND TYPE OF SUBSTRATE. 2.03 PRIMERS AND SEALERS: TYPE AS RECOMMENDED BY MANUFACTURER OF FLOOR COVERING/RUBBER BASE FOR CONDITIONS OF INSTALLATION. 2.04 JOINT FILLER AND NEUTRAL CLEANER: TYPE MADE OR RECOMMENDED MY MANUFACTURER OF FLOOR COVERING FOR CONDITIONS ON INSTALLATION. 2.05 SUBMIT THE FOLLOWING: 1. ONE (1) SAMPLE OF EACH SCHEDULED PRODUCT. 3.01 INSTALL MATERIALS IN COMPLIANCE WITH MANUFACTURER'S PRINTED SPECIFICATIONS AND INSTALLATION INSTRUCTIONS. PAINTING SHALL BE SUBSTANTIALLY COMPLETED BEFORE START OF LAYING FLOORING AND PERMANENT MECHANICAL SYSTEM MUST BE IN OPERATION. WHERE DIFFERENT COLORED MATERIALS OCCUR IN ADJOINING ROOMS OR SPACES, MAKE COLOR CHANGE ON A LINE CENTERING UNDER DOOR WHEN CLOSED. TIGHTLY BOND TO SUBSTRATE WITH CONTINUOUS CONTACT THROUGHOUT AREA OF EACH PIECE. 3.02 INSTALL BASE WITH NEATLY MITERED INSIDE CORNERS, AND BACK BEVELED WRAPPED OUTSIDE CORNERS. INSTALL STRAIGHT WITHOUT GLARING BULGES AND GAPS. 3.03 RESILIENT FLOORING AND RESILIENT BASE ADHESIVES TO MEET THE FOLLOWING MINIMUM VOC LIMIT REQUIREMENTS; SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE 1168. A. VCT AND ASPHALT TILE ADHESIVES -50 G/L B. RUBBER FLOOR ADHESIVES -60 G/L C. COVE BASE INSTALLATION -50 G/L 3.04 PROVIDE 5% ATTIC STOCK OF EACH SCHEDULED FINISH. SECTION 096500 -RESILIENT FLOORING 1.01. REFER TO FINISH SCHEDULE FOR PRODUCT SPECIFICATIONS. 1.02 SUBMIT THE FOLLOWING: A. PRODUCT DATA. B. ONE (1) SAMPLE OF EACH PRODUCT INDICATING STYLE, COLOR AND SIZE IN MINIMUM 12" LENGTHS. 2.01 PRODUCTS: A. RESILIENT BASE (B): SEE FINISH SCHEDULE FOR SPECIFICATIONS B. RESILIENT TRANSITION (TS): SEE FINISH SCHEDULE FOR SPECIFICATIONS 2.02 APPLY RESILIENT BASE TO WALLS, COLUMNS, CASEWORK AND OTHER PERMANENT FIXTURES IN ROOMS OR AREAS WHERE BASE IS SCHEDULED. 2.03 INSTALL BASE IN AS LONG OF LENGTHS AS IS PRACTICABLE WITH TIGHT, BUTTED JOINTS, FREE OF GAPS, BUBBLES, AND TEARS. 2.04 TIGHTLY BOND BASE TO BACKING THROUGHOUT THE LENGTH AND HEIGHT OF EACH PIECE WITH CONTINUOUS CONTACT AT HORIZONTAL AND VERTICAL FINISHES. 2.05 WHERE POSSIBLE PROVIDE AND INSTALL PRE-MOLDED CORNERS. INSTALL PRE-MOLDED CORNERS BEFORE INSTALLING STRAIGHT PIECES. 2.06 JOB-FORMED CORNERS: 1. FOR CONTOURED MILLWORK STYLE RESILIENT BASE, REFER TO MANUFACTURER'S RECOMMENDATIONS FOR FORMING MITERED CORNERS. 2. OUTSIDE CORNERS: USE STRAIGHT PIECES OF MAXIMUM LENGTHS POSSIBLE. FORM WITHOUT PRODUCING DISCOLORATION (WHITENING) AT BENDS. SHAVE BACK OF BASE AT POINTS WHERE BENDS OCCUR AND REMOVE STRIPS PERPENDICULAR TO LENGTH OF BASE THAT ARE ONLY DEEP ENOUGH TO PRODUCE A SNUG FIT WITHOUT REMOVING MORE THAN HALF THE WALL BASE THICKNESS. 3. INSIDE CORNERS: USE STRAIGHT PIECES OF MAXIMUM LENGTHS POSSIBLE. FORM BY CUTTING AN INVERTED V-SHAPED NOTCH IN TOE OF WALL BASE AT THE POINT WHERE CORNER IS FORMED. SHAVE BACK OF BASE WHERE NECESSARY TO PRODUCE A SNUG FIT TO SUBSTRATE. 2.07 RESILIENT ACCESSORY INSTALLATION: 1. RESILIENT MOLDING ACCESSORIES: BUTT TO ADJACENT MATERIALS AND TIGHTLY ADHERE TO SUBSTRATES THROUGHOUT LENGTH OF EACH PIECE. INSTALL REDUCER STRIPS AT EDGES OF FLOOR COVERINGS THAT WOULD OTHERWISE BE EXPOSED. 3.01 PROVIDE 5% ATTIC STOCK OF EACH SCHEDULED PRODUCT. SECTION 096513 -RESILIENT WALL BASE AND ACCESSORIES © DLR GroupRevisions -ALL PROJECT COMMUNICATION TO BE SENT TO MARK REED/MONICA BATES, NOT AOR.5/25/2021 3:31:28 PMC:\Revit\_2020\KH Indianapolis Expansion CD's v_20_hgriffo.rvt23-21100-00 5.26.2021 BID/PERMIT SPECIFICATIONS A0.5250 E. 96TH ST. #580INDIANAPOLIS, IN 46240INDIANAPOLIS, INDIANA07/19/21