Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Kimley-Horn - Indianapolis - Bid Set 5.26.2021_A0.6
1.01 GENERAL: COMPLY WITH CRI 104, SECTION 6.1, "SITE CONDITIONS; TEMPERATURE AND HUMIDITY." 1.02 ENVIRONMENTAL LIMITATIONS: DO NOT INSTALL CARPET TILE UNTIL WET WORK IN SPACES IS COMPLETE AND DRY, AND AMBIENT TEMPERATURE AND HUMIDITY CONDITIONS ARE MAINTAINED AT THE LEVELS INDICATED FOR PROJECT WHEN OCCUPIED FOR ITS INTENDED USE. 1.03DO NOT INSTALL CARPET TILE OVER CONCRETE SLABS UNTIL SLABS HAVE CURED AND ARE SUFFICIENTLY DRY TO BOND WITH ADHESIVE AND CONCRETE SLABS HAVE PH RANGE RECOMMENDED BY CARPET TILE MANUFACTURER. 1.04 WHERE DEMOUNTABLE PARTITIONS OR OTHER ITEMS ARE INDICATED FOR INSTALLATION ON TOP OF CARPET TILE, INSTALL CARPET TILE BEFORE INSTALLING THESE ITEMS. 1.05WARRANTY A. GENERAL WARRANTY: SPECIAL WARRANTY SPECIFIED IN THIS ARTICLE SHALL NOT DEPRIVE OWNER OF OTHER RIGHTS OWNER MAY HAVE UNDER OTHER PROVISIONS OF THE CONTRACT DOCUMENTS AND SHALL BE IN ADDITION TO, AND RUN CONCURRENT WITH, OTHER WARRANTIES MADE BY CONTRACTOR UNDER REQUIREMENTS OF THE CONTRACT DOCUMENTS. B. SPECIAL CARPET TILE WARRANTY: WRITTEN WARRANTY, SIGNED BY CARPET TILE MANUFACTURER AGREEING TO REPLACE CARPET TILE THAT DOES NOT COMPLY WITH REQUIREMENTS OR THAT FAILS WITHIN SPECIFIED WARRANTY PERIOD. WARRANTY DOES NOT INCLUDE DETERIORATION OR FAILURE OF CARPET TILE DUE TO UNUSUAL TRAFFIC, FAILURE OF SUBSTRATE, VANDALISM, OR ABUSE. FAILURES INCLUDE, BUT ARE NOT LIMITED TO, MORE THAN 10 PERCENT LOSS OF FACE FIBER, EDGE RAVELING, SNAGS, RUNS, AND DELAMINATION. 1. WARRANTY PERIOD: 10 YEARS FROM DATE OF SUBSTANTIAL COMPLETION. 1.06 EXTRA MATERIALS A. FURNISH EXTRA MATERIALS DESCRIBED BELOW, BEFORE INSTALLATION BEGINS, THAT MATCH PRODUCTS INSTALLED AND THAT ARE PACKAGED WITH PROTECTIVE COVERING FOR STORAGE AND IDENTIFIED WITH LABELS DESCRIBING CONTENTS. 1. CARPET TILE: FULL-SIZE UNITS EQUAL TO 5 PERCENT OF AMOUNT INSTALLED FOR EACH TYPE INDICATED, BUT NOT LESS THAN 10 SQ. YD. (8.3 SQ.M). 1.07 SUBMIT THE FOLLOWING: 1. SHOP DRAWINGS INDICATING PATTERN TYPE, LOCATION, AND DIRECTION. 2. SHOP DRAWINGS INDICATING TRANSITION DETAILS TO OTHER FLOORING MATERIALS. 2.01 CARPET TILE (CPT): SEE FINISH SCHEDULE FOR SPECIFICATIONS. CARPET AND CARPET ADHESIVE ARE PROVIDED BY TENANT AND INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE CARPET SEAMING DIAGRAM, REQUIRED QUANTITIES INCLUDING WASTE AND ATTIC STOCK AND PROVIDE TO TENANT 2.02 INSTALLATION ACCESSORIES A. TROWELABLE LEVELING AND PATCHING COMPOUNDS: LATEX-MODIFIED, HYDRAULIC-CEMENT-BASED FORMULATION PROVIDED BY OR RECOMMENDED BY CARPET TILE MANUFACTURER. B. ADHESIVES: WATER-RESISTANT, MILDEW-RESISTANT, NONSTAINING TYPE TO SUIT PRODUCTS AND SUBFLOOR CONDITIONS INDICATED, THAT COMPLIES WITH FLAMMABILITY REQUIREMENTS FOR INSTALLED CARPET TILE AND THAT IS RECOMMENDED BY CARPET TILE MANUFACTURER. 3.01 EXAMINATION A. EXAMINE SUBSTRATES, AREAS, AND CONDITIONS FOR COMPLIANCE WITH REQUIREMENTS FOR MAXIMUM MOISTURE CONTENT, ALKALINITY RANGE, INSTALLATION TOLERANCES, AND OTHER CONDITIONS AFFECTING CARPET TILE PERFORMANCE. VERIFY THAT SUBSTRATES AND CONDITIONS ARE SATISFACTORY FOR CARPET TILE INSTALLATION AND COMPLY WITH REQUIREMENTS SPECIFIED. B. CONCRETE SUBFLOORS: VERIFY THAT CONCRETE SLABS COMPLY WITH ASTM F 710 AND THE FOLLOWING: 1. SLAB SUBSTRATES ARE DRY AND FREE OF CURING COMPOUNDS, SEALERS, HARDENERS, AND OTHER MATERIALS THAT MAY INTERFERE WITH ADHESIVE BOND. DETERMINE ADHESION AND DRYNESS CHARACTERISTICS BY PERFORMING BOND AND MOISTURE TESTS RECOMMENDED BY CARPET TILE MANUFACTURER. 2. SUBFLOOR FINISHES COMPLY WITH MANUFACTURER'S REQUIREMENTS FOR RECEIVING CARPET TILE. 3. SUBFLOORS ARE FREE OF CRACKS, RIDGES, DEPRESSIONS, SCALE, AND FOREIGN DEPOSITS. 3.02 PREPARATION A. GENERAL: COMPLY WITH CRI 104, SECTION 6.2, "SITE CONDITIONS; FLOOR PREPARATION," AND CARPET TILE MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS FOR PREPARING SUBSTRATES INDICATED TO RECEIVE CARPET TILE INSTALLATION. B. USE TROWELABLE LEVELING AND PATCHING COMPOUNDS, ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS, TO FILL CRACKS, HOLES, AND DEPRESSIONS IN SUBSTRATES. C. CONCRETE MOISTURE TEST: PERFORM MOISTURE TESTS ON CONCRETE FLOORS REGARDLESS OF THE AGE OR GRADE LEVEL WITH A MINIMUM OF THREE TESTS FOR THE FIRST 1000 SQUARE FEET. THE TEST SHALL BE CALCIUM CHLORIDE TEST. ONE TEST SHALL BE CONDUCTED FOR EVERY 1000 SQ. FT. OF FLOORING. THE TEST SHALL BE CONDUCTED AROUND THE PERIMETER OF THE ROOM, AT COLUMNS AND WHERE MOISTURE MAY BE EVIDENT. THE MOISTURE EMISSION FROM THE CONCRETE SHALL NOT EXCEED 3.0 LBS. PER 1000 SQ. FT. IN 24 HOURS. FOR THE MOST ACCURATE RESULTS, THE WEIGHT OF THE CALCIUM CHLORIDE DISH SHALL BE MADE ON THE JOB SITE AT THE START AND END OF EACH TEST. A DIAGRAM OF THE AREA SHOWING THE LOCATION AND RESULTS OF EACH TEST SHALL BE SUBMITTED. IF THE TEST RESULTS EXCEED THE LIMITATIONS, THE INSTALLATION SHALL NOT PROCEED UNTIL THE PROBLEM HAS BEEN CORRECTED. D. CONCRETE PH TEST: PERFORM PH TESTS ON CONCRETE FLOORS REGARDLESS OF THE AGE OR GRADE LEVEL. IF THE PH IS GREATER THAN 9, NEUTRALIZE PRIOR TO BEGINNING THE INSTALLATION. 3.03INSTALLATION A. GENERAL: COMPLY WITH CRI 104, SECTION 13, "CARPET MODULES (TILES)." B. INSTALLATION METHOD: AS RECOMMENDED IN WRITING BY CARPET TILE MANUFACTURER. C. CUT AND FIT CARPET TILE TO BUTT TIGHTLY TO VERTICAL SURFACES, PERMANENT FIXTURES, AND BUILT-IN FURNITURE INCLUDING CABINETS, PIPES, OUTLETS, EDGINGS, THRESHOLDS, AND NOSINGS. BIND OR SEAL CUT EDGES AS RECOMMENDED BY CARPET TILE MANUFACTURER. D. EXTEND CARPET TILE INTO TOE SPACES, DOOR REVEALS, CLOSETS, OPEN-BOTTOMED OBSTRUCTIONS, REMOVABLE FLANGES, ALCOVES, AND SIMILAR OPENINGS. E. MAINTAIN REFERENCE MARKERS, HOLES, AND OPENINGS THAT ARE IN PLACE OR MARKED FOR FUTURE CUTTING BY REPEATING ON FINISH FLOORING AS MARKED ON SUBFLOOR. USE NONPERMANENT, NONSTAINING MARKING DEVICE. F. INSTALL PATTERN AS NOTED IN INTERIOR MATERIAL LIST. 3.04 PROVIDE 5% ATTIC STOCK OF EACH SPECIFIED CARPET WHEN PROVIDING TENANT WITH CARPET QUANTITIES SECTION 096813 -CARPET TILE 1.01 WORK INCLUDES SURFACE PREP & PAINTING OF INTERIOR & EXTERIOR SURFACES AS INDICATED ON PLANS. UNLESS OTHERWISE INDICATED PAINTING DOES NOT INCLUDE: PREFINISHED MATERIAL; PLUMBING PIPING; CONCEALED INTERIOR SPACES OR PLENUMS, INTERIOR STRUCTURAL STEEL OTHER THAN EXPOSED STEEL COLUMNS IN FINISHED AREAS. 1.02 PAINT EXPOSED SURFACES, EXCEPT WHERE THE PAINT SCHEDULES INDICATE THAT A SURFACE OR MATERIAL IS NOT TO BE PAINTED OR IS TO REMAIN NATURAL. IF THE PAINT SCHEDULES DO NOT SPECIFICALLY MENTION AN ITEM OR A SURFACE, PAINT THE ITEM OR SURFACE THE SAME AS SIMILAR ADJACENT MATERIALS OR SURFACES WHETHER OR NOT SCHEDULES INDICATE COLORS. IF THE SCHEDULES DO NOT INDICATE COLOR OR FINISH, THE DESIGNER WILL SELECT FROM STANDARD COLORS AND FINISHES AVAILABLE. PAINTING INCLUDES FIELD PAINTING OF EXPOSED BARE AND COVERED PIPES AND DUCTS (INCLUDING COLOR CODING), HANGERS, EXPOSED STEEL AND IRON WORK, AND PRIMED METAL SURFACES OF MECHANICAL & ELECTRICAL EQUIPMENT. DO NOT PAINT PRE-FINISHED ITEMS, CONCEALED SURFACES, FINISHED METAL SURFACES, OPERATING PARTS, & LABELS. 1.03 PREPARATION: PAINT ONLY WHEN PROPER SURFACE PREPARATION HAS BEEN MADE ACCORDING TO MANUFACTURER'S REQUIREMENTS AND WHEN AMBIENT CONDITIONS OF TEMPERATURE AND HUMIDITY ARE WITHIN RECOMMENDED RANGES. 1.04 EXTERIOR PAINTING SHALL NOT BE UNDERTAKEN WHEN AIR OR SURFACE TEMPERATURE IS BELOW 50 DEGREES OR FOLLOWING RAIN, FROST, OR CONDENSATION. 1.05 INTERIOR TEMPERATURE OF 65 DEGREES SHALL BE MAINTAINED DURING APPLICATION AND CURING OF PAINT SURFACES. 1.06 TOPS AND BOTTOMS OF DOORS ARE TO BE FINISHED IN SAME MANNER AS DOOR FACINGS. 1.07 CONFORM TO MANUFACTURER'S REQUIREMENTS FOR APPLICATION OF PAINT FINISHES. MATERIALS SHALL BE APPLIED FREE OF RUNS, SAGS, WRINKLES, STREAKS, SHINERS, HOLIDAYS, AND BRUSH MARKS. 1.08 FORMULATE PRIME COATS WITH COLOR OF FINISH COATS. MINIMUM DRY FILM THICKNESS (MDFT OR DFT): SPECIFIED BY MINIMUM DRY FILM THICKNESS IN MILLIMETERS, PER COAT. WHERE MANUFACTURER'S RECOMMENDATIONS REQUIRE GREATER DRY FILM THICKNESS', OR IF NO MDFT IS SPECIFIED, FOLLOW MANUFACTURER'S RECOMMENDATIONS. SECTION 099100 -PAINTING 1.09 PAINT SYSTEM: TWO OR MORE COATS OF PAINT, GENERALLY CONSISTING OF A PRIME COAT AND ONE OR MORE COATS OF FINISH PAINT. PAINT SYSTEM INCLUDES SURFACE PREPARATION AND REQUIRED PRETREATMENT. REFER TO PAINT SCHEDULE FOR PAINT SYSTEM DESCRIPTIONS BASED ON MATERIAL TO BE PAINTED AND SHEEN INDICATED. A. A. SELECT PRIMER FROM SPECIFIED PRODUCTS FOR SUBSTRATE INVOLVED. FIELD APPLIED PRIMER COAT IS REQUIRED FOR EACH MATERIAL SCHEDULED FOR PAINT UNLESS THE PRIMER WAS SHOP APPLIED. B. TOUCH UP OF DAMAGED SHOP APPLIED PRIMERS IS A REQUIREMENT OF THIS SECTION. C. TWO TOPCOATS ARE REQUIRED FOR EACH PAINT SYSTEM UNLESS OTHERWISE INDICATED. D. INTERIOR FINISHING REQUIRED: 1. WOOD: SATIN FINISH ALKYD SATIN IMPERVO ENAMEL OVER ALKYD OR LATEX PRIME COAT. 2. WOOD STAIN/CLEAR FINISH: ALKYD PENETRATING STAIN WITH ONE COAT SANDING SEALER WITH TWO COATS SATIN FINISH. 3. PLASTER/DRYWALL: ONE COAT LATEX PRIMER, TWO COATS VINYL ACRYLIC LATEX. 4. MASONRY: FLAT FINISH, TWO COATS FLAT LATEX OVER ONE COAT BLOCK FILLER; SEMI GLOSS FINISH, TWO COATS SEMI GLOSS LATEX OVER BLOCK FILLER. 5. EPOXY: TWO COATS WATERBORNE ACRYLIC EPOXY ENAMEL OVER APPROPRIATE SUBSTRATE PRIMER. 6. FERROUS METAL: TWO COATS SATIN FINISH ALKYD OVER ONE COAT RUST INHIBITIVE LATEX PRIMER. 2.01 PAINT MATERIALS (P): SEE FINISH SCHEDULE FOR COLOR AND MATERIAL DESIGNATIONS. 2.02 PRE-WALL COVERING PRIMER: ROMAN PRO-977 ULTRA PRIME PRIMER/SEALER, ZINSSER; SHIELDZ UNIVERSAL PRE-WALL COVERING PRIMER OR AS REQUIRED BY WALL COVERING MANUFACTURER. 2.03SUBMIT THE FOLLOWING: 1. ONE (1) 8" X 10" SAMPLES OF EACH SCHEDULED FINISH / COLOR ON SCHEDULED SUBSTRATE (PROVIDE 1/4" THICK SUBSTRATE FOR SAMPLES OF PAINT ON GYPSUM BOARD). 3.01 ITEMS AND SURFACES NOT TO BE PAINTED: A. FURRED SPACES, INTERIOR OF VERTICAL SHAFTS, OR SPACES ABOVE SUSPENDED CEILINGS, INCLUDING ITEMS WITHIN THESE SPACES. B. WALL, CEILING OR FLOOR SURFACES OF ROOMS NOT SCHEDULED ON THE ROOM FINISH SCHEDULE FOR FINISHING. C. ITEMS OCCURRING ON/IN WALL, CEILING OR FLOOR SURFACES NOT SCHEDULED ON THE ROOM FINISH SCHEDULE FOR FINISHING EXCEPT THE FOLLOWING: 1. UNPRIMED OR SHOP PRIMED STEEL OR GALVANIZED STEEL DOORS & FRAMES (PAINT AS SPECIFIED FOR THESE ITEMS IN THE INTERIOR PAINTING SCHEDULE). 2. UNPRIMED OR SHOP PRIMED STEEL OR GALVANIZED STEEL RAILINGS, LADDERS AND STAIRS (PAINT AS SPECIFIED FOR THESE ITEMS IN THE INTERIOR PAINTING SCHEDULE). 3. STEEL DOORS AND FRAMES (PAINT AS SPECIFIED FOR STEEL). 4. STEEL HANDRAILS (PAINT AS SPECIFIED FOR STEEL). 5. OTHER EXPOSED BARE OR PRIME PAINTED STEEL, GALVANIZED STEEL, UNFINISHED ALUMINUM, INCLUDING FASTENERS/ANCHORS (PAINT AS SPECIFIED FOR METALS OF TYPE INVOLVED). D. NEW MATERIALS WHICH HAVE BEEN FURNISHED WITH A FACTORY APPLIED DECORATIVE FINISH. E. SPRINKLER HEADS 3.02 UNLESS EXCLUDED UNDER THE ITEMS AND SURFACES NOT TO BE PAINTED PARAGRAPH, PAINT NEW SURFACES AS FOLLOWS: A. GIVE NEW SURFACES AND ITEMS ONE COAT OF PRIMER AND TWO COATS OF TOPCOAT, (UNLESS INDICATED OTHERWISE) USING APPROPRIATE PAINT SYSTEM FOR SUBSTRATE INVOLVED AND USING TOPCOAT OF TYPE SCHEDULED. B. WHERE FIELD APPLIED PRIME COATS ARE SCHEDULED, THEY MAY BE OMITTED FOR SHOP PRIMED ITEMS. TOUCH UP DAMAGED AREAS WITH SCHEDULED COMPATABLE PRIMERS. C. SPOT PRIME PATCHED AND DAMAGED FINISHES OF EXISTING SURFACES AND ITEMS (UNLESS TOPCOAT MANUFACTURER REQUIRES COMPLETE PRIMING) USING APPROPRIATE PRIMER SPECIFIED FOR SUBSTRATE INVOLVED, FOLLOWED BY TWO TOPCOATS USING TYPE OF TOPCOAT MATCHING EXISTING IN SHEEN AND COLOR (UNLESS OTHERWISE NOTED), AND EXTENDING OVER THE ENTIRE SURFACE TO THE NEAREST BREAK IN THE SURFACE. D. INTERIOR EXPOSED STRUCTURE OVERHEAD INCLUDING EXPOSED MECHANICAL AND ELECTRICAL WORK OVERHEAD IN THESE SPACES. E. CONCEALED SPRINKLER HEAD CAPS TO MATCH CEILING FINISH SURFACE IF HEADS RESIDE IN NON- CEILING WHITE AREAS. FACTORY PAINTED CAPS TO MATCH SPECIFIED COLOR. SEE FINISH SCHEDULE FOR COLOR PAINT SPECIFICATION. 3.03 PROTECT FINISHES OF OTHER TRADES OR SURFACES. CLEAN UP SPILLS, OVER SPRAY, & OTHER IMPERFECTIONS IMMEDIATELY. PROPERLY DISPOSE OF UNUSED MATERIALS & CONTAINERS IN ACCORDANCE WITH APPLICABLE RULES & REGULATIONS. FOLLOW PROPER VENTILATION REQUIREMENTS & ADHERE TO SAFETY DATA SHEET REQUIREMENTS. 3.04 FURNISH MAINTENANCE STOCK EQUAL TO 5 GALLONS OF PRIME INTERIOR FIELD COLOR AND ONE GALLON CONTAINERS OF OTHER PAINT FINISHES WITH MIX FORMULAS CLEARLY MARKED ON THE CONTAINERS. 3.05 ALL PAINTS TO MEET THE FOLLOWING MINIMUM VOC LIMIT REQUIREMENTS; TOPCOAT PAINTS -GREEN SEAL STANDARD GS-11. A. NON-FLAT -150 G/L B. FLAT -50 G/L 3.06 ALL ANTI-CORROSIVE AND ANTI-RUST PAINTS TO MEET THE FOLLOWING MINIMUM VOC LIMIT REQUIREMENTS; GREEN SEAL STANDARD GS-03. A. GLOSS -50 G/L B. SEMI-GLOSS -250 G/L C. FLAT -250 G/L 3.07 ALL OTHER ARCHITECTURAL COATINGS, PRIMERS AND UNDERCOATS TO MEET THE FOLLOWING MINIMUM VOC LIMIT REQUIREMENTS; SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE 1113 A. FLOOR COATINGS -100 G/L B. PRIMERS, SEALERS AND UNDERCOATERS -200 G/L C. RUST PREVENTATIVE COATINGS -400 G/L D. SPECIALTY PRIMERS -350 G/L E. STAINS -250 G/L K. VERIFY ATTIC STOCK REQUIRED WITH OWNER. PROVIDE MINIMUM ONE (1) GALLON, FOR FIELD PAINTS AND MINIMUM (1) QUART FOR ACCENT PAINTS AS SPECIFIED. 1.01 SUBMITTALS: SUBMIT MANUFACTURER'S SPECIFICATIONS AND INSTALLATION INSTRUCTIONS FOR EACH TYPE OF PRODUCT SPECIFIED. FOR FIRE EXTINGUISHER CABINETS INCLUDE ROUGH-IN DIMENSIONS, DETAILS SHOWN MOUNTING METHODS, RELATIONSHIPS OF BOX AND TRIM TO SURROUNDING CONSTRUCTION, DOOR HARDWARE, CABINET TYPE AND MATERIALS, TRIM STYLE, DOOR CONSTRUCTION, PANEL TYPE, AND MATERIALS. 1.02 REFER TO ARCHITECTURAL FLOOR PLAN FOR LOCATIONS.ALL LOCATIONS AND QUANTITIES AS PER NFPA AND LOCAL CODES AND ORDINANCES. 1.03 FIRE EXTINGUISHER CABINET (FEC): SEE FINISH & EQUIPMENT SCHEDULE FOR SPECIFICATIONS 2.01 PRODUCTS: A. FIRE EXTINGUISHER CABINETS TO BE EQUAL TO LARSEN'S MANUFACTURING CO. ARCHITECTURAL SERIES OR EQUAL. ACCEPTABLE ALTERNATIVES JL INDUSTRIES "AMBASSADOR" MODEL 1015, OR POTTER-ROEMER 1700 SERIES. 1. FEC-01 : PRIMED CABINET PAINTED IN FIELD 2. FEC-02: STAINLESS STEEL CABINET 2.02 FIRE EXTINGUISHERS TO BE LARSEN'S MANUFACTURING CO. MODEL #MP10. 2.03 FURNISH MULTIPURPOSE DRY CHEMICAL FIRE EXTINGUISHERS BEARING UL RATING 2A:1DBC. 3.01 INSTALL MATERIALS WHERE INDICATED, IN ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTRUCTIONS. 3.03 CLEAN INSIDE AND OUTSIDE OF FIRE EXTINGUISHER CABINETS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. SECTION 104400 -FIRE PROTECTION SPECIALTIES 1.01 SUBMITTALS: SUBMIT MANUFACTURER’S SPECIFICATIONS AND INSTALLATION INSTRUCTIONS FOR TENANT PROVIDED AED CABINETS INCLUDE ROUGH-IN DIMENSIONS, DETAILS SHOWN, MOUNTING METHODS, RELATIONSHIPS OF BOX AND TRIM TO SURROUNDING CONSTRUCTION, DOOR HARDWARE, CABINET TYPE AND MATERIALS, TRIM STYLE, DOOR CONSTRUCTION, PANEL TYPE, AND MATERIALS. 1.02 REFER TO ARCHITECTURAL FLOOR PLAN FOR LOCATIONS. 1.03AUTOMATED EXTERNAL DEFIRBILLATOR (AED) TO BE LIFEPAK® CR2 DEFIBRILLATOR WITH LIFELINKCENTRAL™ AED PROGRAM MANAGER. 1.04 MOUNT WHERE INDICATED, IN ACCORDANCE WITH THE MANUFACTURER’S PRINTED INSTRUCTIONS AND ADA RECOMMENDATIONS SECTION 104401 -AUTOMATED EXTERNAL DEFIRBILLATOR (AED) A. ALL ELECTRICAL, DATA, AND SWITCH DEVICES AND COVERS TO BE WHITE, UNLESS NOTED OTHERWISE AS SUPPLIED BY THE MANUFACTURER. DEDICATED OUTLET DEVICES ARE TO BE ORANGE WITH COVERS TO MATCH ALL OTHER COVERS. DEVICE/COVER STYLE TO BE "DECORA" SCREWLESS. 1. AT ALL WOOD SURFACES, DEVICES AND COVERPLATES TO BE BROWN. 2. AT ALL TILE/GLASS SURFACES, DEVICES AND COVERPLATES TO BE BRUSHED STAINLESS STEEL. B. ALL ADJACENT SWITCHES SHALL BE CONSTRUCTED IN A SINGLE MULTI-GANG SWITCH BOX. C. FURNITURE WHIPS ARE SHOWN IN APPROXIMATE LOCATIONS, REFER TO FURNITURE INSTALLATION PLANS FROM FURNITURE DEALER AND COORDINATE EXACT LOCATION IN FIELD. D. ALL ADJACENT ELECTRICAL / DATA DEVICES SHALL BE INSTALLED HORIZONTALLY CENTERED AND LEVEL WITH EACH OTHER. SECTION 26 00 00 -ELECTRICAL © DLR GroupRevisions -ALL PROJECT COMMUNICATION TO BE SENT TO MARK REED/MONICA BATES, NOT AOR.5/25/2021 3:31:29 PMC:\Revit\_2020\KH Indianapolis Expansion CD's v_20_hgriffo.rvt23-21100-00 5.26.2021 BID/PERMIT SPECIFICATIONS A0.6250 E. 96TH ST. #580INDIANAPOLIS, IN 46240INDIANAPOLIS, INDIANA07/19/21