Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Kimley-Horn - Indianapolis - Bid Set 5.26.2021_A2.1
REF.RF MWMW F.E.C.F.E .C. DN UPDN UP REF.LIMIT OF WORK1. REFER TO SPECIFICATIONS SHEETS FOR ADDITIONAL NOTES. 2. CONTRACTOR IS TO CHALK WALL LAYOUT ON CONCRETE FLOOR PRIOR TO BEGINNING OF PARTITION CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRYWALL LAYOUT FROM THE CONSTRUCTION PLAN. CONTRACTOR SHALL NOT BEGIN FRAMING WITHOUT APPROVAL OF WALL LAYOUT BY THE ARCHITECT. 3. AT LOCATIONS WHERE PARTITIONS ADJOIN MULLIONS, CENTERLINE OF PARTITION IS TO ALIGN WITH CENTERLINE OF MULLION UNLESS NOTED OTHERWISE. PROVIDE CLOSURE STRIP/ SOUND SEAL AT THESE LOCATIONS. DO NOT PENETRATE CURTAIN WALL OR EXTERNAL WINDOW SYSTEM WITH SCREWS, AND OR MECHANICAL FASTENERS, ETC. 4. NEW DRYWALL CONSTRUCTION MEETING EXISTING DRYWALL CONSTRUCTION IN THE SAME PLANE SHALL BE FLUSH WITH NO VISIBLE JOINTS SHOWING. 5. ALL DOORS SHALL HAVE MANEUVERING CLEARANCES AS REQUIRED BY ADA/LOCAL ACCESSIBILITY STANDARDS. 6. WHERE IT IS DEEMED NECESSARY TO ENSURE STABILITY, CONTRACTOR SHALL PROVIDE ADDITIONAL BRACING, ANCHORING, AND/OR BLOCKING IN STUD PARTITIONS. ALL WOOD/BLOCKING SHALL BE FIRE-TREATED AS REQUIRED. 7. ALL PARTITIONS TO BE TYPE "P12" UNLESS NOTED OTHERWISE. REFER TO PARTITION SCHEDULE AND CONSTRUCTION PLAN FOR PARTITION LOCATIONS. CONSTRUCTION PLAN NOTES 8. ALL WALL ANGLES ARE EITHER 90 DEGREES OR 45 DEGREES UNLESS NOTED OTHERWISE. 9. FURR-OUT CORE WALLS AND COLUMNS AT ALL LOCATIONS WHERE ELECTRICAL, TELEPHONE OR PLUMBING OCCUR. REFER TO PLANS FOR LOCATIONS AND COORDINATE MEP PLANS & SPECIFICATIONS. 10. ALL MILLWORK/WOODWORK IS TO BE FABRICATED IN ACCORDANCE WITH ARCHITECTURAL WOODWORK INSTITUTE CUSTOM STANDARDS, UNLESS NOTED OTHERWISE. 11. PROVIDE/RELOCATE FIRE SPRINKLER HEADS IN A 2'x2' PATTERN CENTERED IN TILE. COORDINATE WITH LIGHTING FIXTURES AND ABOVE CEILING CONDITIONS. REFER REFLECTED CEILING PLAN. 12. CONTRACTOR MAY NOT RE-USE EXISTING PLUMBING AT NEW SINKS AND FIXTURES UNLESS EXISTING PLUMBING IS WITHIN 24" OF NEW SINK OR FIXTURE. 13. VERIFY FLOOR PENETRATIONS WITH ARCHITECT, STRUCTURAL ENGINEER AND LANDLORD PRIOR TO INSTALLATION. ALL PENETRATIONS TO BE SEALED PER APPLICABLE CODE. 14. WHERE NOTED ON PLAN, INSTALL 3/4" A.C. GRADE NON- COMBUSTIBLE 48" W X 96" H PLYWOOD BACKBOARD FOR TELEPHONE EQUIPMENT WHICH SHALL BE PAINTED TO MATCH ADJACENT WALL. PLYWOOD SHALL BE SMOOTH, SQUARE, AND HAVE EDGES FILLED AND SANDED SMOOTH. INSTALL WITH TOP OF PLYWOOD AT 8'-4" A.F.F. UNLESS NOTED OTHERWISE. 15. GENERAL CONTRACTOR SHALL PERFORM FIELD SURVEY OF EXISTING WINDOW TREATMENTS AND PROVIDE SEPARATE LINE-ITEM PRICE FOR REPAIRS OR SUPPLEMENTAL PARTS TO ALL EXISTING WINDOW TREATMENTS AT ALL EXTERIOR WINDOWS, TO REPAIR CORDS, WANDS, SLATS IN BLINDS, ETC.. TO ENSURE THAT ALL COMPONENTS ARE IN PLACE AND CONSISTENT IN APPEARANCE AND OPERATION. CONTRACTOR IS TO PROVIDE AND INSTALL NEW BUILDING STANDARD WINDOW COVERINGS AT ALL EXTERIOR WINDOWS WHERE MISSING TO MATCH ADJACENT EXISTING TYPE, STYLE & COLOR. 16. UNDER NO CIRCUMSTANCES IS THE CONTRACTOR TO FURNISH OR INSTALL ANY MATERIALS, ADHESIVES, OR PRODUCTS CONTAINING ASBESTOS. 17. PROVIDE NEW FIRE EXTINGUISHERS IN CABINETS (FEC) PER CODE. VERIFY LOCATIONS WITH FIRE MARSHALL. FIRE EXTINGUISHER TO BE MOUNTED AS INDICATED ON MOUNTING HEIGHT DIAGRAM SHEET A0.3. CONTRACTOR TO PROVIDE CUT SHEETS/DETAILS AND LOCATIONS FOR APPROVAL IN ACCORDANCE WITH ARCHITECTS SPECIFICATIONS. COORDINATE FINISH WITH SPECIFICATION SHEETS UNLESS NOTED OTHERWISE. 18. CONTRACTOR IS RESPONSIBLE FOR FIELD DIMENSIONS OF ALL MILLWORK, GLASS, DOOR OPENINGS, ETC. 19. ANY CONFLICTS IN DIMENSIONS DUE TO FIELD CONDITIONS, TYPOGRAPHICAL ERRORS, OR OTHER SIMILAR CONDITIONS, ARE TO BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. 20. ALL SALVAGEABLE MATERIALS SCHEDULED TO BE DEMOLISHED, SUCH AS DOORS, FRAMES, HARDWARE, MILLWORK, AND OTHER RE-USABLE ITEMS ARE TO BE RETURNED TO BUILDING STOCK, UNLESS NOTED OTHERWISE. COORDINATE ALL SALVAGE AND STORAGE OF THESE ITEMS WITH BUILDING MANAGEMENT. 21. VERIFY CONSTRUCTION TYPE OF ALL EXISTING DEMISING WALLS AT PERIMETER OF LEASE SPACE PRIOR TO BID. ENSURE ALL DEMISING WALLS ARE EXTENDED TO DECK WITH SOUND INSULATION IN ENTIRE WALL CAVITY. ALL NEW DEMISING WALLS ARE TO MATCH THE CONSTRUCTION TYPE 'P13', MEETING THE REQUIREMENTS OF BUILDING STANDARDS. 22. VERIFY THAT ALL ITEMS WHICH PROTRUDE FROM THE WALL IN THE CIRCULATION PATH AND HAVE A LEADING EDGE ABOVE 27" SHALL BE LIMITED TO 4" MAXIMUM PROJECTION FROM THE WALL UP TO A HEIGHT OF 80 INCHES. THIS INCLUDES WALL MOUNTED TELEVISION SCREENS AND ARTWORK FURNISHED BY THE OWNER AND/OR TENANT. AREA NOT IN CONTRACT (NIC) NEW PARTITION -TYPE 'P12' (TYP. U.N.O.) FURNITURE WALL SYSTEM (BY OTHERS) EXISTING PARTITION TO REMAIN DOOR IDENTIFIER, SEE DOOR SCHEDULE SHEET A9.1 FIRE EXTINGUISHER CABINET EXISTING GYP. BD. COLUMN ENCLOSURE TO REMAIN NEW 4X8 FIRETREATED TELEPHONE BACKBOARD MOUNTED VERTICAL, JUST BELOW CEILING DIMENSION / LEADERS ALIGN FACES PARTITIONS CENTERED ON MULLION PLUMBING, ACCESSORIES, & EQUIPMENT SYMBOL OBJECT NOTATIONS: E EXISTING R RELOCATED N NEW ? FEC N 4' - 6" NOTE TEXT CL MW-01 CONSTRUCTION PLAN LEGEND CARD READER, REFER TO ELECTRICAL PLANSCR NEW PARTITION -TYPE 'P13' STANDARD PARTITION U.N.O. 3 5/8" STUD TO UNDERSIDE OF GRID -WITH SOUND CONTROL IN WALL AND ABOVE CEILING REFER P12/SHEET A7.1 KIMLEY-HORN STANDARD PARTITIONS STANDARD PARTITION AT MOTHER'S, CONFERENCE AND SERVER ROOM U.N.O. 3 5/8" STUD TO DECK -WITH SOUND CONTROL REFER P13/SHEET A7.1 VIA CLEARANCE 9'-11 1/8" VIA CLEARANCE 9'-11 1/8" VIA CLEARANCE 9'-7 1/8" VIA CLEARANCE 9'-7 1/8"VIA CLEARANCE8'-11 1/8"VIA C L E A R A N C E 1 0' - 0 "1/A11.1A7.1 54 Sim CONFERENCE 512 OPEN 508 OPEN 509 OFFICE 503 OPEN 507 OFFICE 513 OFFICE 514 OFFICE 502 OFFICE 501 OFFICE 510 OFFICE 511 10'-0" 10'-0" 10'-0" 1 0'- 4 7/8 "13'- 7 1/8" 10'-4"10'-4" 10'-4" 2'-1"V.I.F.10'-2 5/8"TYP. THROUGHOUT LIMIT OF WORK 1 2 4 3 5 5 COFFEE 50010'-4 1/4"500 A E D P13 P13P13P13P13VIA CLEARANCE 4'-4"P13P13P13P136 6 6 P13P13 1 0' - 4 " HUDDLE 504 OFFICE 506 OFFICE 505 P13 P1310'-2 7/8"VIA CLEARANCE 9'-7 1/8"VIA CLEARANCE9'-1 3/8"VIA CLEARANCE9'-10"2/A11.11'-8 1/2" V.I.F. 3'-6 3/8"6"1'-7 1/4" 9 3/8"P13P13 P13 P13 P133/A11.17 8 10'-6"8"8'-0 7/8"© DLR GroupRevisions -ALL PROJECT COMMUNICATION TO BE SENT TO MARK REED/MONICA BATES, NOT AOR.5/25/2021 3:31:43 PMC:\Revit\_2020\KH Indianapolis Expansion CD's v_20_hgriffo.rvt23-21100-00 5.26.2021 BID/PERMIT CONSTRUCTION PLAN A2.1250 E. 96TH ST. #580INDIANAPOLIS, IN 46240INDIANAPOLIS, INDIANA1. CONTRACTOR TO VERIFY ALL EXISTING BLINDS ARE IN WORKING CONDITION. PROVIDE SEPARATE LINE-ITEM PRICE TO REPAIR/REPLACE AS NEEDED. 2. CONTRACTOR TO PROVIDE AND INSTALL NEW COPPER WATER LINE WITH CONTROL VALVE FOR TENANT COFFEE MAKER. REFER TO PLUMBING DRAWINGS. 3. CONTRACTOR TO PROVIDE AND INSTALL SEMI-RECESSED FIRE EXTINGUISHER CABINET AS SPECIFIED AT THIS LOCATION. MAINTAIN CONTINUITY OF FIRE-RATED WALLS AS REQUIRED, TYPICAL. LARSENS VERTICAL DUO DOOR WITH CLEAR ACRYLIC GLASS SS2409-RM. 4. CONTRACTOR TO INSTALL TENANT PROVIDED AED CABINET. SEE SPECIFICATION PRIOR TO FRAMING: LIFEPAK® CR2 DEFIBRILLATOR WITH LIFELINKCENTRAL⢠AED PROGRAM MANAGER. MOUNT PER ADA RECOMMENDATIONS. 5. ALIGN CENTERLINE OF PARTITION WITH CENTERLINE OF MULLION/COLUMN. REFER 54/A7.1 FOR PARTITION AND MULLION CONNECTION DETAIL. 6. CONTRACTOR TO VERIFY IF SOUND INSULATION EXISTS INSIDE THE CAVITY OF THE EXISTING DEMISING WALLS. CONTRACTOR IS TO INSTALL NEW ROLL BATT INSULATION INSIDE EXISTING PARTITION AND ABOVE CEILING 3'-0" ON EITHER SIDE OF FINISHED WALL. CONTRACTOR TO EXTEND INDICATED PARTITION TO DECK IF CONDITION IS NOT EXISTING. 7. PATCH AND REPAIR FLOOR TO CREATE A LEVEL SURFACE FOR NEW FLOOR FINISHES. 1/2" FOR EVERY 10'-0". TYPICAL. 8. PATCH AND REPAIR ALL AFFECTED AREAS TO "LIKE NEW" CONDITION, WHERE INDICATED ON PLAN. KEYED NOTES A. CONTRACTOR TO REPAIR EXISTING CONCRETE SLAB THROUGHOUT LIMIT OF WORK AS REQUIRED. FLOAT FLOOR PRIOR TO INSTALLATION OF NEW FLOOR FINISH AND MODULAR WALL SYSTEMS. FLOOR TO BE LEVELED TO 1/2" IN 10'-0" MAX RADIUS. MUST BE COMPLETE PRIOR TO FRAMING. B. CONTRACTOR TO VERIFY ALL EXISTING BLINDS ARE IN WORKING CONDITION. PROVIDE SEPARATE LINE-ITEM PRICE TO REPAIR/REPLACE AS NEEDED. C. ALL PARTITIONS TO BE P12, TYPICAL UNO. D. CONTRACTOR TO NOTIFY DLR GROUP IMMEDIATELY OF ANY DISCREPANCIES BETWEEN DIMENSIONS SHOWN AND FIELD CONDITIONS. E. OFFICE FRONTS ARE TENANT PROVIDED. CONTRACTOR TO COORDINATE WITH TENANT VENDOR. REFER TO 'AZ' SHEETS. REFER A3.1 FOR DETAIL AT HEADER. CONTACT SHANA HILL: shill@businessinteriors.com972.523.4687. NO BLOCKING REQUIRED ** PROJECT NOTES APPLY TO ENTIRE LIMIT OF WORK ** PROJECT NOTES 13612 24 48 PLAN NORTH TRUE NORTH SCALE: 1/8" = 1'-0" CONSTRUCTION PLAN 07/19/21