Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Kimley-Horn - Indianapolis - Bid Set 5.26.2021_A9.1
REF.RFMWMWF.E.C.MWCRDN UPDN UP REF.LIMIT OF WORKD1 1-3/4" THICK P.LAM DOOR, REFER TO DOOR SCHEDULE FOR FINISH F1 STANDARD 3-PIECE DOOR FRAME ELECTRICALLY LOCKED EGRESS DOORS SHALL COMPLY WITH 2018 IBC SECTION 1010.1.9.10. NO DELAYED EGRESS IS PERMITTED GROUP 1 -SINGLE SOLID DOOR (WITH SECURITY) MATCH HARDWARE OF EXISTING EGRESS AND SERVER DOORS WITHIN SUITE. REFER SHEET A9.1 'KIMLEY-HORN SECURITY SPECIFICATIONS' FOR GENERAL CONTRACTOR SCOPE OF WORK AT SECURITY DOOR GL-01 1/4" THICK TEMPERED CLEAR GLASS GL-02 3/8" THICK TEMPERED CLEAR GLASS GL-03 1/2" THICK TEMPERED CLEAR GLASS W/POLISHED EDGES GL-04 3/4" THICK TEMPERED CLEAR GLASS W/POLISHED EDGES DOOR GLAZING LEGEND AL ALUMINUM GL GLASS HM HOLLOW METAL DOOR & FRAME ASSEMBLY SCW SOLID CORE WOOD DOOR/FRAME CONSTRUCTION TYPE LEGEND CAA CLEAR ANODIZED ALUMINUM P-XX PAINT -SEMI-GLOSS FINISH PL PLASTIC LAMINATE ST STAINED WOOD VENEER DOOR/FRAME FINISH LEGEND A. DOOR AND FRAME ASSEMBLIES SHALL COMPLY WITH ALL SCHEDULED REQUIREMENTS, GENERAL NOTES & LEGENDS, DOOR AND FRAME DETAILS, AND PROJECT SPECIFICATIONS. B. CONTRACTOR TO COORDINATE DOOR HARDWARE HANDING & SIZING, AND INTEROPERABILITY OF COMPONENTS BASED ON SCHEDULED HARDWARE MANUFACTURERS DOCUMENTATION AND CORRESPONDING DETAILS. C. ALL RATED DOOR & FRAME ASSEMBLIES SHALL INCLUDE ALL HARDWARE REQUIRED FOR RATING, WHICH SHALL BE UL APPROVED AND LABELED D. COORDINATE TENANT KEYWAYS WITH BUILDING ENGINEER AND TENANT REQUIREMENTS E. ALL ALUMINUM DOOR FRAMES SHALL BE "WESTERN INTEGRATED", "WILSON PARTITIONS", OR EQUAL. F. ALL DOOR HARDWARE FINISH SHALL BE: CLEAR ANODIZED ALUMINUM) G. PAINTED DOORS AND FRAMES ARE TO BE PAINTED WITH SEMIGLOSS TO MATCH ADJACENT WALL. H. ALL LOCKSETS ARE TO BE COMPATIBLE WITH BUILDING MANAGEMENT MASTER. COORDINATE KEYING MATRIX WITH TENANT AND BUILDING MANAGEMENT DOOR/FRAME/HARDWARE NOTES METAL STUD WALL -SEE PLANS FOR WALL TYPES SEE SPECIFICATION SHEET A0.5 FOR HEAD/JAMB/ SILL DETAILS @ METAL STUD FRAMING ALUMINUM KNOCK DOWN FRAME - SEE DOOR AND FRAME SCHED. DOOR -SEE DOOR AND FRAME SCHED. SEALANT BOTH SIDES, TYP SILL AND COMPRESSION ANCHORS AS OCCUR 0' - 0 1/2" 0' - 0 1/2"0' - 4"WALL WHERE OCCURS ACOUSTICAL SOUND BATT INSULATION DOOR PER PLAN. REFER TO DOOR SCHEDULE FOR ADDITIONAL INFORMATION SIDE-LIGHT WHERE OCCURS. SEE DOOR SCHEDULE / PLAN FOR ADDITIONAL INFORMATION PARTITION PER PLAN SCHEDULED DOOR STOP TYP. SWITCH / T-STAT TYP REFER TO DOOR SCHEDULE FOR HARDWARE INFORMATION DOOR PER PLAN. REFER TO DOOR SCHEDULE FOR ADDITIONAL INFORMATION SIDE-LIGHT WHERE OCCURS. SEE DOOR SCHEDULE / PLAN FOR ADDITIONAL INFORMATION PARTITION PER PLAN SWITCH / T-STAT TYP REFER TO DOOR SCHEDULE FOR HARDWARE INFORMATION 6".6". @ SLIDING DOOR@ SWING DOOR S SS S CRIPPLE STUD INFILL STUD HEADER TRACK JAMB STUDS FASTENER NON-LOAD BEARING SINGLE TRACK HEADER AT DOOR CRIPPLE STUD INFILL STUD HEADER TRACK JAMB STUDS FASTENER LOAD BEARING BOX HEADER AT DOOR ANGLE HEADER MEMBERS CONFERENCE 512 OPEN 508 OPEN 509 OFFICE 503 OPEN 507 OFFICE 513 OFFICE 514 OFFICE 502 OFFICE 501 OFFICE 510 OFFICE 511 COFFEE 500 500 OFFICE 505 HUDDLE 504 OFFICE 506 © DLR GroupRevisions -ALL PROJECT COMMUNICATION TO BE SENT TO MARK REED/MONICA BATES, NOT AOR.5/25/2021 3:31:56 PMC:\Revit\_2020\KH Indianapolis Expansion CD's v_20_hgriffo.rvt23-21100-00 5.26.2021 BID/PERMIT DOOR SCHEDULE & DOOR/FRAME DETAILS A9.1250 E. 96TH ST. #580INDIANAPOLIS, IN 46240INDIANAPOLIS, INDIANASCALE: 3" = 1'-0" ALUM DR FRAME -HEAD/JAMB DOOR TYPE ELEVATIONS DOOR FRAME TYPE ELEVATIONS DOOR HARDWARE GROUPS HARDWARE SPECIFICATIONS SCALE: 1 1/2" = 1'-0" TYPICAL DOOR & SWITCH LAYOUT SCALE: 1" = 1'-0" TYP DOOR OPENING FOR LIGHT GAUGE FRAMING DOOR PLAN KIMLEY-HORN SECURITY SPECIFICATIONS FINISH: BUILDING STANDARD -US32D (SATIN STAINLESS STEEL) LEVER/ROSE STYLE: SARGENT B LEVER / LN ROSE BUTT HINGES: HAGER COMPANIES: NO. 1279 OR BB1279 - 4.5". PROVIDE IN WIDTH SUFFICIENT OT CLEAR TRIM WHEN DOOR SWINGS 180-DEGREES, WHETHER OR NOT SHOWN TO DEGREE OF OPENING ON PLAN. MORTISE: EQUAL TO SARGENT 8200 OFFICE LOCKSET: EQUAL TO SARGENT 8205 PASSAGE LATCHSET: EQUAL TO SARGENT 8215 STOREROOM LOCKSET: EQUAL TO SARGENT 8204 PRIVACY LOCKSET: EQUAL TO DORMA M9996 WITH DORMA 79019 OCCUPANCY INDICATOR ELECTRIFIED LOCKSET: REFER SECURITY HARDWARE NOTES MAGNETIC LOCK: REFER SECURITY HARDWARE NOTES REMOTE RELEASE: REFER SECURITY HARDWARE NOTES EMERGENCY RELEASE: REFER SECURITY HARDWARE NOTES DOOR STOP: OMNIA 7001 OVERHEAD CONCEALED CLOSERS AT WOOD DOORS: LCN 2000 SERIES AT GLASS DOORS: RIXSON SERIES (WITH HOLD-OPEN FUNCTION WHERE SPECIFIED) DECORATIVE PULLS: CRL LADDER PULLS; FINISH -US32D (SATIN STAINLESS STEEL) 1-1/4" DIA. x 30" LONG OFFSET PIVOTS: RIXSON SERIES, 1-1/2" OFFSET HEAVY DUTY SLIDING: GRANT SLIDING DOOR HARDWARE, MODEL BASED ON WEIGHT OF ASSEMBLY FRAMEWORKS ALUMINUM FRAME ASSEMBLY KEYPAD LOCK: KABA SIMPLEX 5012 EXTRA HEAVY DUTY COMBINATION DOOR CORES: SMALL FORMAT IC CYLINDER: FALCON A8 FLOOR STOP: TRIMCO W1212RP US26D OR EQ DOOR VIEWER: ASD DOOR VIEWER DS238 BLACK DOOR NUMBER ROOM NAME RATED OPENING SIZE DOOR FRAME DOOR NUMBER HARDWARE SET COMMENTS WIDTH HEIGHT THICK. TYPE MATERIAL FINISH TYPE MATERIAL FINISH 500 EGRESS 3' - 0"8' - 3 1/2"1 3/4" D1 P.LAM P.LAM F1 ALUM. CLR. ANOD. 500 GROUP 1 CARD READER. MATCH EXISTING CORRIDOR DOORS HEIGHT. SPLIT FINISH AS REQUIRED BY LANDLORD. 513 2' - 8 7/8" 9' - 9 1/4"1/2" D_ALUM./GLASS CLR.ANOD./CLR. F_ ALUM. CLR. ANOD. 513 WIDTH INDICATES OPENING SIZE. VERIFY LEAF SIZE DOOR DETAILS SCALE: 1/16" = 1'-0" DOOR PLAN Hardware provided by General Contractor • All door hardware including • Contacts • Motion RTE • Push button RTE (when required) • Electrified locking hardware • HID ProxPro with keypad Model 5358 at main entry door(as well as secondary door between reception area and the rest of the office where applicable), 35 bit, HID Miniprox Model 5365 at all other doors, 35 bit; cards to be Wiegand format 35 bit Corporate 1000 • All cabling required for the access control system • Power supplies for all hardware • Fire alarm relay for integrating fire alarm system and access control system (when required) Hardware Provided by Kimley-Horn • Model (S2-NN-E2R-WM) Description (S2 Network Node, 2 Reader, in Standard Enclosure (6 Open Exp. Slots) • Model (S2-ACM) Description (Blade, Access Control: Adds 2 Readers, 4 Inputs, 4 Outputs) • Battery PS-12120F2 GENERALCONTRACTORSCOPE OF WORK General Contractor (GC) will install all hardware related to the access control system. GC is also responsible for all permitting related to the access control system. The GC can use any hardware if it is compatible with the S2 network controller (Model S2-NN-E2R-WM) and S2 ACM Boards (Model S2-ACM) provided by Kimley-Horn. Scope includes • Installing all door hardware • Electrified Locking hardware • Card Reader (with waterproof cover if located on exterior of building) • Motion RTE • Push Button RTE (when required) • Door Contact • Latch Gard for strike locks • Run cable compatible with S2 ACM for door hardware back to server room • Connecting door hardware to S2 ACM boards following the layout provided by Kimley- Horn • Installing power supply for locking hardware • Installing S2 network node S2-NN-E2R-WM or equivalent and S2-ACM blades • Configure S2 Node with IP address info provided by Kimley-Horn. • Physically connect S2 Node to Kimley-Horn network hardware onsite • Connecting access control system to fire alarm when required • Testing all systems with Kimley-Horn programing team • Access control system will be fully functional at least 3 weeks prior to Certificate of Occupancy. Fully functional is defined as: • All hardware is installed, working and tested to the satisfaction of the Kimley- Horn programing team. • All required permitting is completed. • Access control system is ready to pass any inspections required to receive Certificate of Occupancy. KIMLEY-HORN SCOPE OF WORK Kimley-Horn will program the access control system and help test the doors with local installer. This will be done remotely and/or over the phone. Kimley-Horn will provide layout of cables connections to the S2 ACM boards for local installer to follow. 07/19/21