JJ FF FF FF REF.RF MWMWF.E.C.MWD PD PP DPD TV+66TV+66CR+44 +44 +44 520RNEMAF .E . C . DN UPDN UP U/C TV+66TV+66HKREF.+44 +36 520RNEMA520RNEMALIMIT OF WORK1. REFER TO SPECIFICATIONS SHEET A0.10, AND MEP SPECIFICATIONS FOR ADDITIONAL NOTES. 2. ALL WORK IS TO BE INSTALLED IN ACCORDANCE WITH REQ. OF THE MANUF, CODES, AND ORDINANCES 3. CONTRACTOR TO FIELD COORDINATE LOCATIONS OF ALL NEW POWER AND COMMUNICATIONS OUTLETS WITH EXISTING CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCY FROM PLAN. COORDINATE ELECTRICAL/DATA AND LIGHT SWITCH LOCATIONS WITH FURNITURE AND EQUIPMENT SHOWN ON ARCHITECTS POWER PLAN. 4. VERIFY TYPE OF FLOOR SLAB WITH BUILDING'S STRUCTURAL ENGINEER. PROVIDE ALL SAFEGUARDS AS REQUIRED BY ENGINEER INCLUDING, BUT NOT LIMITED TO SLAB X-RAY, PRIOR TO CONDUCTING ANY SLAB PENETRATIONS. INSTALL FIRE PROOFING AT ALL PENETRATIONS PER LOCAL CODES AND ORDINANCES. 5. UNLESS NOTED OTHERWISE IN ENGINEERED DRAWINGS (IF PROVIDED), ALL "DEDICATED CIRCUIT" ELECTRICAL OUTLETS ARE TO BE LABELED AS DEDICATED. 6. "POKE-THRU" ELECTRICAL DEVICES, WHEN PLACED IN MULTIPLES, MUST HAVE A MINIMUM SEPARATION OF TWO (2'-0") FEET O.C. AND NOT MORE THAN ONE (1) HOLE PER 65 SQUARE FEET OF AREA OF FLOOR SPAN OR AS REQUIRED FOR COMPLIANCE WITH APPLICABLE UL LISTING, (WHICHEVER MAY BE THE MOST RESTRICTIVE). 7. THIS DRAWING HAS BEEN PREPARED TO ASSIST THE OWNER. ARCHITECT'S POWER PLAN INDICATES LOCATION ONLY. REFER TO ELECTRICAL ENGINEERING DOCUMENTS FOR CODE COMPLIANCE. 8. CONTRACTOR SHALL FURNISH AND INSTALL ALL ELECTRICAL DEVICES AND PERFORM ALL ELECTRICAL WORK AS SHOWN OR IMPLIED ON ALL PLANS. POWER/DATA PLAN NOTES 9. ALL WORK IS TO BE INSTALLED IN ACCORDANCE WITH THE NATIONAL BOARD OF FIRE UNDERWRITERS, PUBLIC UTILITIES AND TELEPHONE COMPANIES, AND OTHER AUTHORITIES HAVING JURISDICTION. 10. ALL MATERIALS REQUIRED SHALL CONFORM WITH THE STANDARDS SET BY THE UNDERWRITERS LABORATORIES INC. IN EVERY CASE WHERE SUCH A STANDARD HAS BEEN ESTABLISHED FOR THE INSTALLATION INDICATED. 11. ELECTRICAL WORK SPECIFIED IN MILLWORK, LAMPS AND OTHER FIXTURES SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. CUTOUTS FOR SWITCHES, OUTLETS, AND WIRING DEVICES SHOWN IN MILLWORK ARE TO BE CUTOUT BY THE MILLWORK FABRICATOR AND COORDINATED WITH THE ELECTRICAL CONTRACTOR. 12. CONTRACTOR TO PROVIDE AND INSTALL LOW VOLTAGE DATA CABLING, COORDINATE WITH KIMLEY-HORN IT. 13. ELECTRICAL OUTLETS TO BE REMOVED ARE TO HAVE CABLING/CONDUIT TAKEN OUT OF PLENUM AND BACK TO ORIGINAL PANEL. PATCH/REPAIR WALL AND PREPARE FOR SCHEDULED FINISH. CAP/FILL AND PROVIDE FIRE SEAL FOR CORE DRILL & MONUMENT OUTLETS AS REQUIRED. 14. CONTRACTOR TO ENSURE THAT ALL "EXISTING TO REMAIN" DUPLEX OUTLETS ARE IN WORKING ORDER, AND DOCUMENT NEW OR EXISTING CIRCUIT NUMBERS IN AS-BUILT DRAWINGS. ALL NEW OUTLET RECEPTACLES AND COVER PLATES SHALL BE AS SPECIFIED ON SHEET A0.6 UNDER SECTION 26 00 00 ELECTRICAL UNLESS NOTED OTHERWISE. RETROFIT ALL EXISTING NON-STANDARD RECEPTACLES AND COVER PLATES TO MATCH NEW SPECIFIED RECEPTACLES AND COVER PLATES. 15. IF NEEDED ANY ADDITIONAL DATA OR COMMUNICATION OUTLETS NOT SHOWN ON PLAN ARE TO BE CUT AND INSTALLED BY TENANT'S VENDOR; COORDINATE LOCATIONS WITH ARCHITECT. 16. CONTRACTOR TO FIELD VERIFY LOCATION OF ALL EXISTING ELECTRICAL OUTLETS. NOTIFY DESIGNER OF ANY DISCREPANCY FROM PLAN. 17. ALL EXISTING ELECTRICAL OUTLETS LOCATED ON PARTITIONS TO BE DEMOLISHED ARE NOT SHOWN AND ARE TO BE REMOVED INCLUDING ALL CONDUIT AND WIRING BACK TO THEIR RESPECTIVE ELECTRICAL PANELS. 18. DUE TO FIELD CONDITIONS, SOME EXISTING TELEPHONE/ELECTRICAL OUTLETS MAY NOT BE INDICATED ON PLAN. CONTRACTOR TO FIELD VERIFY LOCATIONS OF ALL EXISTING POWER/COMM OUTLETS. EXISTING OUTLETS WITHIN 2'-0" OF A NEW OUTLET OF THE SAME TYPE AS INDICATED ON PLAN MAY REMAIN IN LIEU OF THE NEW OUTLET. EXISTING OUTLETS AT PRIVATE OFFICES (DESK SIDE) MUST BE NEW, REFER 11/A15.2. EXISTING BUILDING STANDARD DUPLEX OUTLETS MAY REMAIN IF NOT IN CONFLICT WITH NEW CONSTRUCTION, VERIFY WITH ARCHITECT. ALL OTHER EXISTING OUTLETS ARE TO BE REMOVED UNLESS NOTED OTHERWISE. IF OUTLET FALLS WITHIN REUSE RANGE, VERIFY REUSE WITH ARCHITECT. 19. PROVIDE MIN. 2" DIAMETER CONDUIT RUNNING FROM TENANT'S TELEPHONE BOARD TO BUILDING TELEPHONE ROOM. 20. ELECTRICAL SUB-METER IS REQUIRED ON ALL SUPPLEMENTAL AIR CONDITIONING UNITS. CONFIRM WITH LANDLORD 21. ALL DEDICATED CIRCUIT ELECTRICAL OUTLETS ARE TO BE LABELED AS DEDICATED. 22. EACH ELECTRICAL CIRCUIT SHALL NOT EXCEED EIGHT (8) GENERAL USE ELECTRICAL OUTLETS. 23. ALL OUTLETS LOCATED WITHIN 6'-0" OF PLUMBING SHALL BE G.F.C.I. OUTLETS. 24. ELECTRICAL SHOWN ON PLAN IS NEW, UNLESS NOTED OTHERWISE. SUBSCRIPTS BY OUTLETS INDICATE: "N" = NEW OUTLET "R" = EXISTING OUTLET TO BE RELOCATED (PATCH WALL) "E" = EXISTING OUTLET TO REMAIN 25. ALL NEW WALL OUTLETS ARE TO BE MOUNTED AT 18" A.F.F TO CENTERLINE, UNLESS NOTED OTHERWISE. 26. ELECTRICAL CIRCUITS SERVING OFFICE COMPUTERS SHALL NOT EXCEED FOUR (4) COMPUTERS ON 20A CIRCUIT. 27. ALL OUTLETS MOUNTED IN BACKSPLASHES ARE TO BE MOUNTED HORIZONTALLY. REFER ELEVATIONS. POWER/DATA PLAN LEGEND POWER SYMBOL DESCRIPTION DUPLEX RECEPTACLE 120V; +18" AFF U.O.N. QUAD RECEPTACLE 120V; +18" AFF U.O.N. FLUSH COMBINATION DUPLEX POWER/DATA FLOOR OUTLET JUNCTION BOX, POWER FEED; +18" AFF U.O.N. JUNCTION BOX, CONDUIT STUB UP AT FLOOR FOR HARD-WIRED POWER CONNECTION DATA SYMBOL DESCRIPTION TELEPHONE & DATA OUTLET; +18" AFF U.O.N.; PROVIDE DROPS AT EACH LOCATION AS DIRECTED BY KIMLEY-HORN U.O.N. DATA JUNCTION BOX FOR PHONE FLUSH COMBINATION QUADRAPLEX POWER/DATA FLOOR OUTLET FLUSH POWER FURNITURE FEED FLOOR OUTLET; + 18" AFF U.O.N. WALL MOUNTED POWER FURNITURE FEED OUTLET; +18" AFF U.O.N. WALL MOUNTED TEL/DATA FURNITURE FEED; +18" AFF U.O.N.; PROVIDE DROPS AT EACH LOCATION AS DIRECTED BY KIMLEY-HORN FLUSH COMBINATION QUADRAPLEX POWER/DATA/AV FLOOR OUTLET +42 AV FLUSH FLOOR TEL/DATA FURNITURE FEED; PROVIDE DROPS AT EACH LOCATION AS DIRECTED BY KIMLEY-HORN FF DEDICATED DUPLEX RECEPTACLE 120V, NEMA 5-20R; +18" AFF U.O.N. DEDICATED QUAD RECEPTACLE 120V, NEMA 5-20R; +18" AFF U.O.N. LOW VOLTAGE/DATA CABLING TO BE PROVIDED BY GENERAL CONTRACTOR. COORDINATE WITH KIMLEY-HORN IT FOR REQUIREMENTS. SECURITY SYMBOL DESCRIPTION CARD READER (MOUNTING HEIGHT 48" A.F.F U.N.O.) PROVIDED AND INSTALLED BY CONTRACTORCR EB EXIT RELEASE BUTTON/ADA DOOR OPERATOR BUTTON (MOUNTING HEIGHT 48" A.F.F U.N.O.) PROVIDED AND INSTALLED BY CONTRACTOR 8 1 3 4 5 TYP. THROUGHOUT LIMIT OF WORK 9 2 7AED CONFERENCE 512 OPEN 509 OFFICE 503 OPEN 507 OFFICE 513 OFFICE 514 OFFICE 502 OFFICE 501 OFFICE 510 OFFICE 511 OPEN 508 OFFICE 505 HUDDLE 504 OFFICE 506 EQ EQ 1 10 COFFEE 500 5 6 11 © DLR GroupRevisions -ALL PROJECT COMMUNICATION TO BE SENT TO MARK REED/MONICA BATES, NOT AOR.5/25/2021 3:32:30 PMC:\Revit\_2020\KH Indianapolis Expansion CD's v_20_hgriffo.rvt23-21100-00 5.26.2021 BID/PERMIT POWER/DATA PLAN A15.1250 E. 96TH ST. #580INDIANAPOLIS, IN 46240INDIANAPOLIS, INDIANA1. CONFERENCE ROOM REQUIREMENTS A. FLOOR CORE -QUAD POWER AND THREE (3) DATA OUTLETS HOUSED IN FLOOR CORE RUNNING TO CHIEF BOX. TWO (2) DATA IN FLOOR CORE TERMINATING AT PATCH PANEL. CONTRACTOR TO PROVIDE AND INSTALL FLOOR CORE DEVICE AS INDICATED ON A15.1. CONTRACTOR TO COORDINATE EXACT FLOOR CORE LOCATION WITH TENANT FURNITURE VENDOR. B. FLOOR CORE-TO-CONDUIT -CONTRACTOR TO PROVIDE AND INSTALL 1 1/2" CONDUIT FROM FLOOR CORE TO WALL AS SHOWN. CONDUIT TO TERMINATE WITHIN CHIEF BOX AS SHOWN ON A15.3. C. CHIEF BOXES -REFER TO A15.3 FOR CONTRACTOR PROVIDED AND INSTALLED CHIEF BOX SPECIFICATION. STANDARD HDMI CABLE -END TO END. NO ETHERNET HDMI CABLE ALLOWED. CONTRACTOR TO PROVIDE AND INSTALL TWO (2) DATA CABLES TERMINATING AT PATCH PANEL AND STANDARD DUPLEX POWER MOUNTED AS SHOWN. PROVIDE BACKING AS NOTED ON SHEET 15.3. D. MONITOR ARM -CONTRACTOR TO PROVIDE AND INSTALL MONITOR ARM AS INDICATED ON A15.3. CONTRACTOR TO INSTALL TENANT PROVIDED TV. 2. WIRELESS ACCESS POINT BY GENERAL CONTRACTOR LOCATIONS AS DIRECTED BY TENANT IT. LOW VOLTAGE TO BE PROVIDED BY GENERAL CONTRACTOR. 3. SEE SECURITY HARDWARE REQUIREMENTS A0.07 4. CONTRACTOR TO MOUNT ALL OUTLETS ABOVE COUNTERTOP HORIZONTALLY REFER TO PLAN FOR MOUNTING HEIGHT. SEE ELEVATIONS FOR EXACT LOCATIONS. 5. POWER FOR TENANT PLOTTER TO BE NEMA 5-20R. REFER LOW VOLTAGE PLAN FOR QUANTITY OF DATA CABLES. 6. CONTRACTOR TO ROUTE POWER FOR TENANT COPIER THROUGH WORKSTATION WITH MC SHIELDED CABLE FROM FURNITURE WHIP THROUGH FURNITURE RACEWAY AND WIRING HARNESS AS REQUIRED TO TERMINATE IN WORKSTATION PANEL. CONTRACTOR TO SURFACE MOUNT A NEMA 5-20R ON SYSTEMS FURNITURE. 7. LOW VOLTAGE/DATA CABLING TO BE PROVIDED BY GENERAL CONTRACTOR -REFER A16.0 FOR LOCATIONS. COORDINATE WITH KIMLEY-HORN IT FOR REQUIREMENTS. KEYED NOTES 13612 24 48 PLAN NORTH TRUE NORTH 8. CONTRACTOR TO ENSURE PLACEMENT OF POWER/ DATA OUTLETS TO BE BETWEEN 2'-3" AND 5' -0" FROM THE CORNER. REFER TO ENLARGED TYPICAL OFFICE PLAN 11/A15.2. 9. FLOOR OUTLET LOCATIONS TO BE VERIFIED BY TENANT FURNITURE VENDOR PRIOR TO INSTALLATION. FIRESAFE ALL OPENINGS 10. U/C OUTLET FOR INSTA HOT UNDER COUNTER WATER HEATER. REFER MEP. 11. CONTRACTOR TO PROVIDE AND INSTALL REMOTE RELEASE FOR FRONT DOORS AT S IT TO STAND DESK. GC TO COORDINATE WITH TENANT A. CONTRACTOR TO ENSURE PLACEMENT OF POWER/ DATA OUTLETS TO BE BETWEEN 2'-3" AND 5' -0" FROM THE CORNER. REFER TO ENLARGED TYPICAL OFFICE PLAN 11/A15.2. B. FLOOR OUTLET LOCATIONS TO BE VERIFIED BY TENANT FURNITURE VENDOR PRIOR TO INSTALLATION. FIRESAFE ALL OPENINGS C. CONTRACTOR TO PROVIDE AND INSTALL CONDUIT, RING AND PULL STRING FOR ALL DATA OUTLETS, TYPICAL THROUGHOUT LIMIT OF WORK. GENERAL CONTRACTOR TO PROVIDE CONNECTION TO SERVER ROOM. D. CONTRACTOR IS REQUIRED TO CONNECT FURNITURE WHIPS TO BUILDING POWER. E. PROVIDE 1'-0" MIN. LINEAR SPACING BETWEEN BACK BOXES ON OPPOSING SIDES OF PARTITION. PROVIDE SOUND SEAL PUTTY OR WRAP AT ALL CONNECTION BOXES AT THIS LOCATION. F. REFER A15.2 FOR WIRING HARNESS AT SYSTEMS FURNITURE. ** PROJECT NOTES APPLY TO ENTIRE LIMIT OF WORK ** PROJECT NOTES SCALE: 1/8" = 1'-0" POWER/DATA PLAN 07/19/21