Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Kimley-Horn - Indianapolis - Bid Set 5.26.2021_A15.4
REF.RF MWMWF.E.C.MWDN UPDN UP REF.LIMIT OF WORKCABLING VENDOR TO INSTALL DATA AND HDMI AS CALLED OUT IN DRAWINGS DEVICE MOUNTING PLATE - DEVICE PLATE THAT WILL ACCEPT UP TO FOUR (4) ORTRONICS SERIES II DUAL MODULAR INSERTS. FOR USE IN THE CENTER COMPARTMENT ONLY. DEVICES SUPPLIED BY OTHERS. 6SER TYP. THROUGHOUT LIMIT OF WORK 1 PTD-1 PTD-1 © DLR GroupRevisions -ALL PROJECT COMMUNICATION TO BE SENT TO MARK REED/MONICA BATES, NOT AOR.5/25/2021 3:32:36 PMC:\Revit\_2020\KH Indianapolis Expansion CD's v_20_hgriffo.rvt23-21100-00 5.26.2021 BID/PERMIT POKE THRU DEVICE PLAN A15.4250 E. 96TH ST. #580INDIANAPOLIS, IN 46240INDIANAPOLIS, INDIANASPECIFICATIONS PTD-1: FLUSH POKE-THRU DEVICE: CONFERENCE ROOMS MANUFACTURER MODEL/DESCRIPTION LEGRAND WIREMOLD 6AT 6" (6ATCBK) DIAMETER CORE TWO (2) #68REC (POWER) ONE (1) 6SER DEVICE MOUNT NOTE: CABLING VENDOR TO INSTALL DATA AND HDMI PTD-1 68 REC RECEPTACLE 20 AMP DUPLEX 6ACT8A RECEPTACLE FOR DATA. PROVIDE RING AND STRING FOR CABLING VENDOR 01. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF THE MANUFACTURER AND CODES/ORDINANCES. 02. CONTRACTOR TO FIELD COORDINATE LOCATIONS OF ALL NEW POWER AND COMMUNICATIONS OUTLETS WITH EXISTING CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCY FROM PLAN. COORDINATE ELECTRICAL/DATA AND LIGHT SWITCH LOCATIONS WITH FURNITURE AND EQUIPMENT SHOWN ON ARCHITECTS POWER PLAN. 03. VERIFY TYPE OF FLOOR SLAB WITH BUILDING'S STRUCTURAL ENGINEER. PROVIDE ALL SAFEGUARDS AS REQUIRED BY ENGINEER INCLUDING, BUT NOT LIMITED TO SLAB X-RAY, PRIOR TO CONDUCTING ANY SLAB PENETRATIONS. INSTALL FIRE PROOFING AT ALL PENETRATIONS PER LOCAL CODES AND ORDINANCES. 04. "POKE-THRU" ELECTRICAL DEVICES, WHEN PLACED IN MULTIPLES, MUST HAVE A MINIMUM SEPARATION OF TWO (2'-0") FEET O.C. AND NOT MORE THAN ONE (1) HOLE PER 65 SQUARE FEET OF AREA OF FLOOR SPAN OR AS REQUIRED FOR COMPLIANCE WITH APPLICABLE UL LISTING, (WHICHEVER MAY BE THE MOST RESTRICTIVE). 05. CONTRACTOR IS TO COMPARE ARCHITECTURAL POWER/COMMUNICATIONS PLAN WITH ASSOCIATED MEP DRAWINGS AND REPORT ANY DISCREPANCIES IMMEDIATELY TO ARCHITECT. 06. THIS DRAWING HAS BEEN PREPARED TO ASSIST THE OWNER. ARCHITECT'S POWER PLAN INDICATES LOCATION ONLY. REFER TO ELECTRICAL ENGINEERING DOCUMENTS FOR CODE COMPLIANCE. 07. CONTRACTOR SHALL FURNISH AND INSTALL ALL ELECTRICAL DEVICES AND PERFORM ALL ELECTRICAL WORK AS SHOWN OR IMPLIED ON ALL PLANS. 08. ALL WORK IS TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE MANUFACTURER, NATIONAL BOARD OF FIRE UNDERWRITERS, PUBLIC UTILITIES AND TELEPHONE COMPANIES, AND OTHER AUTHORITIES HAVING JURISDICTION. 09. ALL MATERIALS REQUIRED SHALL CONFORM WITH THE STANDARDS SET BY THE UNDERWRITERS LABORATORIES INC. IN EVERY CASE WHERE SUCH A STANDARD HAS BEEN ESTABLISHED FOR THE INSTALLATION INDICATED. 10. ALL FLOOR CORES AT WORKSTATIONS/MODULAR FLOOR FEEDS FOR DATA TO HAVE DEDICATED 1 1/2" CONDUITS WITH PULL STRINGS UP TO ACCESSIBLE CEILING SPACE. FLOOR CORES CANNOT BE DAISY CHAINED AND SHALL BE HOME RUNS BACK TO THE SERVER ROOM KEYED NOTES UL LISTED AND UL FIRE CLASSIFIED TO U.S. AND CANADIAN SAFETY STANDARDS. UL FIRE RATED FOR UP TO 2-HOUR RATED FLOORS MAINTAINS THE FIRE CLASSIFICATION OF THE FLOOR CULUS LISTED, METALLIC OUTLET BOX FILE NUMBER E2961. GUIDE QCIT. CULUS LISTED NONMETALLIC OUTLET BOXES & FITTINGS CLASSIFIED FOR FIRE RESISTANCE: FILE R8209, GUIDE CEYY. 1 3612 24 48 PLAN NORTH TRUE NORTH NOTE: REFER TO FLOOR CORE SPECIFICATIONS FOR ADDITIONAL NOTES REFER TO ELECTRICAL PLANS FOR ADDITIONAL REQUIREMENTS SCALE: 1/8" = 1'-0" POKE THRU DEVICE PLAN 1. ALL FLOOR OUTLET LOCATIONS TO BE VERIFIED BY TENANT FURNITURE VENDOR PRIOR TO INSTALLATION. 07/19/21