HomeMy WebLinkAboutKimley-Horn - Indianapolis - Bid Set 5.26.2021_A16.0REF.RF MWMWF.E.C.MWDN UPDN UP REF.LIMIT OF WORKAREA NOT IN CONTRACT (NIC) OBJECT NOTATIONS: E EXISTING R RELOCATED N NEW LOW VOLTAGE PLAN LEGEND DATA DROP DATA DROP NUMERICAL DESIGNATION--- WIRELESS ACCESS POINT LOW VOLTAGE PLAN NOTES A. CONTRACTOR TO BASE LOW VOLTAGE CABLING BID ON INFORMATION FOUND IN ARCHITECTURAL DOCUMENTS. B. CONTRACTOR TO PROVIDE (1) CAT-6 CABLE PER CABLE DROP SYMBOL LOCATED ON PLAN. C. CONTRACTOR TO PROVIDE (1) CAT-6 CABLE PER WIRELESS ACCESS POINT AS LOCATED ON PLANS. D. CONTRACTOR TO PROVIDE LOW VOLTAGE TESTING REPORT TO ENSURE ALL CABLES. E. PROVIDE 8' SERVICE LOOP AT ALL WIRELESS ACCESS POINTS HARDWARE NEEDED DESCRIPTION CABLING CAT6 CABLE PATCH PANELS SPACE FOR 1.75 X THE CURRENT NUMBER OF DATA DROPS WORKSTATION/OFFICE 1 DATA DROP EACH EXTERIOR DOORS "1 DATA DROP, SURFACE MOUNT ABOVE CEILING TILES" SERVER ROOM / IT STORAGE DOORS "1 DATA DROP, SURFACE MOUNT ABOVE CEILING TILES" WIRELESS ACCESS POINTS WIRELESS ACCESS POINT BY TENANT, INSTALLED BY CONTRACTOR. FINAL LOCATIONS AS DIRECTED BY TENANT. CONTRACTOR TO PROVIDE LOW VOLTAGE PRODUCTION ROOMS SEE LOCAL IT STAFF FOR LOCATIONS OTHER PRINTERS SEE LOCAL IT STAFF FOR LOCATIONS CONFERENCE ROOM SETUP CONSULT LOCAL IT THREE (3) DATA OUTLETS HOUSED IN FLOOR CORE RUNNING TO CHIEF BOX. TWO (2) DATA IN FLOOR CORE TERMINATING AT PATCH PANEL. HDMI CONNECTION TO BE STANDARD END-TO-END CONNECTION, NOT OVER ETHERNET. IDF ROOM REQUIRED IF DATA DROPS ARE MORE THEN 300FT FROM SERVER ROOM CONDUIT GC PROVIDES ALL NECESSARY CONDUIT BETWEEN BUILDING MPOE (MAIN POINT OF ENTRY) AND KIMLEY-HORN SERVER ROOM. PATCH PANELS PATCH CABLES PROVIDED BY KIMLEY-HORN LOW VOLTAGE REQUIREMENTS TV 2x CAT6 TO PATCH 3x CAT6 HDMI CABLE TERMINATED IN FEMALE/FEMALE FLOOR CORE CHIEF BOX/TV TO PATCH TO PATCH1 2 CONFERENCE 512 OPEN 509 OFFICE 503 OPEN 507 OFFICE 513 OFFICE 514 OFFICE 502 OFFICE 501 OFFICE 510 OFFICE 511 OFFICE 505 HUDDLE 504 OFFICE 506 1 2 © DLR GroupRevisions -ALL PROJECT COMMUNICATION TO BE SENT TO MARK REED/MONICA BATES, NOT AOR.5/25/2021 3:32:57 PMC:\Revit\_2020\KH Indianapolis Expansion CD's v_20_hgriffo.rvt23-21100-00 5.26.2021 BID/PERMIT LOW VOLTAGE PLAN A16.0250 E. 96TH ST. #580INDIANAPOLIS, IN 46240INDIANAPOLIS, INDIANA13612 24 48 PLAN NORTH TRUE NORTH KEYED NOTES 1. HOME RUN FIBER OPTIC HDMI CABLE FROM CHIEF BOX TO FLOOR CORE, TRUE HDMI, NOT OVER ETHERNET 2. REFER TO 1/A16.0 FOR DATA CABLING AT CONFERENCE ROOM. SCALE: 1/2" = 1'-0"A16.0 1 LOGITECH TAP CONFERENCE ROOM DIAGRAM SCALE: 1/8" = 1'-0" LOW VOLTAGE PLAN 07/19/21