Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M002.0
Indianapolis Design Center352 South County Road 300 EDanville, IN 46122317-745-9984These placement plans have been prepared with the specifications of TrussJoist products based on project information provided. This service is solely intendedfor product application assurance; and, is not intended to circumvent the needfor a design professional as determined by the building codes. The designerof record and/or builder/framer is responsible to assure these drawings arecompatible with the overall project. These documents are not intended to replacethe building plan (which should be used to determine bearing placement).Please insure measurements of the foundation match those provided at the timeof design. Builder is responsible to place load bearing members in load path.Architectural Drawings Prepared By: Structural Drawings Prepared By: 84 Lumber FranklinKevin BeherPyatt BuildersTG141Rev. By Date CommentsDrawn By:DWChecked By: Date:CM 06/23/2021Soho 25145 Sheet 1 of 1 Main Floor System Not to Scale Confirm this layout with the builder and designer of record. Make sure all discrepencies are corrected before ordering floor system. All Dimensions are Approximate and Must Be Field Verified. 11 7/8" TJI Joists 24" O.C. Spacing Framing Connector Summary PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff H1 1 Simpson U414 Designed 16- 10dx1.5 - 6- 10d - - No No Yes H2 2 Simpson MIU2.37/11 Designed 20- 10dx1.5 - 6- 10dx1.5 - - No No Yes H3 1 Simpson MIU2.37/11 Designed 20- 10dx1.5 - 6- 10dx1.5 - - 2 No Yes H4 4 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- Strong-Grip - - 2 No No H5 12 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- Strong-Grip - - No No No H7 2 Simpson IUS2.37/11.88 Designed 10- 10d - 2- Strong-Grip - - No No No H9 6 Simpson IUS2.37/11.88 Designed 10- 10dx1.5 - 2- Strong-Grip - - No No No H10 1 Simpson U14 Designed 14- 10dx1.5 - 6- 10dx1.5 - - 2 No Yes Products PlotID Length Product Plies Net Qty FJ201 20' 0" 11 7/8" TJI 110 joist 1 5 FJ202 18' 0" 11 7/8" TJI 110 joist 2 2 FJ203 14' 0" 11 7/8" TJI 110 joist 1 1 FJ204 8' 0" 11 7/8" TJI 110 joist 1 2 FJ205 6' 0" 11 7/8" TJI 110 joist 1 7 FJ206 4' 0" 11 7/8" TJI 110 joist 1 4 FJ207 42' 0" 11 7/8" TJI 360 joist 2 2 FJ208 28' 0" 11 7/8" TJI 360 joist 1 1 FJ209 26' 0" 11 7/8" TJI 360 joist 1 1 FJ210 24' 0" 11 7/8" TJI 360 joist 1 1 FJ211 20' 0" 11 7/8" TJI 360 joist 1 10 FJ212 18' 0" 11 7/8" TJI 360 joist 1 1 FJ213 24' 0" 11 7/8" TJI 560 joist 1 6 BM201 24' 0" 1 3/4" x 16" 2.0E Microllam LVL 4 4 BM202 20' 0" 1 3/4" x 16" 2.0E Microllam LVL 3 3 BM203 10' 0" 1 3/4" x 9 1/2" 2.0E Microllam LVL 2 2 BM204 6' 0" 1 3/4" x 7 1/4" 2.0E Microllam LVL 2 2 BM206 14' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 BM205 14' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1 BM207 6' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 Ca201 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 9 Blocking PlotID Length Product Plies Net Qty Bk201 2' 0" 11 7/8" TJI 110 joist 1 35 LEVEL NOTES Current Date: 6/23/2021 File Name: tg141_25145.jvl Level Name: Second Floor System Building Code - Design Methodology: IBC 2006 Members with Design Overridden: TJ-Pro Rating (Weighted Average): 39 Minimum Level TJ - Pro Rating & Joist: TJ-Pro rating = 31, joist = FJ213(i11633) Maximum Level TJ - Pro Rating & Joist: TJ-Pro rating = 53, joist = FJ201(i11677) FLOOR Floor Container: FC1 Use/Occupancy: ResidentialLivingAreas Floor Area Loading is: 40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load Operator Added Additional Loads Maximum Allowed Deflection: L/480 Live Load & L/240 Total Load TJ-Pro Rating Information: Weighted Average: 39 Directly Applied Ceiling: Gypsum 1/2" Decking Attachment: Glue and Nail Decking Material: 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF Perpendicular Partition: No Strapping at max 8' o.c.: None Blocking at max 8' o.c.: No Poured Flooring: No 11 7/8" TJI Joists 19.2" O.C. Spacing B1 B4 A3 A3 A3 H2 H2 H2 H2 H2 E1 B4 B1 B1 E1 E1 B3W BM202 VO1 VO2 VO3 VO4 BM205 BM206 BM201BM207 BM204 FJ205FJ211 FJ201 FJ205FJ211 FJ201 FJ205FJ211FJ201FJ205FJ211FJ201 FJ205FJ210 FJ201FJ205FJ202 FJ209 FJ208FJ212 Ca201Ca201Ca201Ca201 Ca201 Ca201 Ca201 Ca201Ca201 Ca201 Bk201 Bk201 Bk201 FJ204FJ206 FJ2111' 0"2' 0" 1' 0" 1' 1 3/8" 4 3/8" Bk201 FJ205 FJ211FJ206 FJ206FJ203 1' 0"2' 0" 4' 11 1/8" 1' 3 3/4"FJ206 FJ2046 1/8"FJ213FJ213FJ213FJ213Ca201 H4 8 9/16" 6 1/2" H4 H4H4 FJ211FJ211FJ211FJ213FJ213FJ207FJ211Bk201 1' 5 7/8" Bk201 4 1/2" H10 BM203H7 H27 5/8"H1 5' 8 7/8"4' 4 7/8" Ca201 H5H5 H5H5 H3H9H5H5 H9H5H5 H5H5 H2 H9 H7 H5H5H9 H9H98' 0"17' 6 3/4"An additional 8 PSF area dead load has been added to account for tile load in the BMA Shower on this floor. Flush beam deeper than floor system. There are different joist series of the same depth specified on this floor system. Verify when installing that the proper TJI® joists are used in the appropriate area. 07/20/21