HomeMy WebLinkAboutC711.0_2020-266_P_L1.1.LPLOT 61ST
ST
ST
STST
STST STST206002040INLETS, VALVES, AND MARKS MADE UPON THE GROUND BYALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOREXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIESSHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAYALL CONSTRUCTION.THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIESEVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES,SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUNDCAUTION !!Know what'sbelow.before you dig.CallRCall 811 or 1-800-382-5544 Before You Begin Any Digging Project.Call 48 hours or 2 working days before you dig.It's Fast, It's Easy and It's the Law in the state of Indiana! CONSULTANTPROJECT NUMBER: TLF-2020-266CARMEL CLAY SCHOOLSPROJECT ISSUE DATE: 10.14.2020DRAWN BY: HHWREV.NO.DESCRIPTIONDATETAC10/14/2020ACONSTRUCTION DOCUMENTSWWW.FHAI.COMARCHITECT317-848-0966350 E NEW YORK ST# 300, INDIANAPOLIS, IN 46204COPYRIGHT 2020 BY FANNING/HOWEY ASSOCIATES, INC.CARMEL HIGHSCHOOL520 E MAIN STREETCARMEL, IN 46032PARKING LOTADDITION19700317No.RESPONSE TO TAC COMMENTS11/25/2020BPROPOSED LANDSCAPE LEGENDPROPOSED 2 1/2" CAL. DECIDUOUS TREEPROPOSED 1" CAL. DEC. TREE (NATIVE)PROPOSED 4' HT. EVERGREEN TREE (NATIVE)PROPOSED SHRUB (3 GAL. CONT./24" HT. B&B)SODDED LAWNKEYNOTESSODDED LAWN, PER SPECIFICATIONSSHREDDED HARDWOOD MULCH PLANTING BEDSHREDDED HARDWOOD MULCH TREE RING - PER DETAILA/L2.1TRENCH BED EDGE PER DETAIL C/L2.1BUFFERYARD (75 TREES)(51) 1" DIA. NATIVE SHADE TREES, SEE PLANT SCHEDULEFOR PLANT TYPES, PLANT TREES IN GROUPS OF 3 OR 5FOR EACH PLANT TYPE THROUGHOUT BUFFERYARD,SPREAD PLANT GROUPS THROUGHOUT BUFFERYARD,DON'T PLANT ALL TREES OF THE SAME TYPE IN 1GROUPING(24) 4' HT. EVERGREEN TREE, SEE PLANT SCHEDULE FORPLANT TYPES, PLANT TREES IN GROUPS OF 3 AND 5 ASSHOWN ON LANDSCAPE PLANPROTECT TREES TO REMAIN PER DETAIL D/L2.1TYPTYPTYPTYPTYPBUFFERYARDBUFFERYARDZONING SUMMARYL1.1LANDSCAPE PLAN1LT-21LT-21UMG2UMG1UMG1UMG1UMG2UMG2UMG8QM2CKL2CKL12RAG6RAG14RAG14RAG10DL6DL17DL10AML10AML9AML6AML4VC7VC1.SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND.2.TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE PROVIDEDBY CIVIL ENVIRONMENTAL CONSULTANTS, INC. THE ENGINEER MAKES NOGUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALLSUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED.3.CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECTAREA INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND DEPTHPRIOR TO ANY OTHER SITE CONSTRUCTION. REPORT ANY DISCREPANCIES TOTHE ENGINEER.4.LANDSCAPING MUST BE PLANTED ACCORDING TO THE DETAILS A & B ONSHEET L2.1. WIRE BASKET, BURLAP AND TWINE MUST BE REMOVED FROMROOTBALL.GENERAL NOTES