Loading...
HomeMy WebLinkAboutC210.0_2020-266_P_G2.1.GPTBM#4 = 810.78 HARROWGATE ADDITIONP.B. 2, PG. 203-205LOT 59 LOT 60 LOT 61 LOT 62 ADJOINER 6 ST STSTSTST STSTST ST STR. #106 TOR:811.50 811.77 813.80 814.92 815.84 STR. #102 TOR:812.50 812.89 STR. #105 TOR:812.00 812.38 812.27 812.65 813.16 812.77 STR. #103 TOR:808.60 STR. #104 TOR:808.60 STR. #101 TOR:809.00 813.71 MEG 815.45 MEG 816.47 MEG 812.58 MEG TC 812.75 BC 812.25 TC 812.39 BC 811.89 TC 813.46 BC 812.96 TC 815.10 BC 814.60 TC 816.02 BC 815.52 TC 816.66 BC 816.16 TC 813.64 BC 813.14 TC 813.76 BC 813.26 TC 810.18 BC 809.68 TC 810.26 BC 809.76 TC 810.08 BC 809.58 TC 810.35 BC 809.85 TC 809.55 BC 809.05 TC 809.94 BC 809.44 TC 809.61 BC 809.11 STR. #112 TOR:809.15 STR. #111 TOR:809.05 STR. #110 TOR:808.98 STR. #109 TOR:812.54 STR. #107 TOR:812.33 STR. #108 TOR:812.46 TC 809.56 BC 809.06 812.65 812.29 809.05 809.52 TC 812.78 BC 812.28 TC 812.47 BC 811.97 TC 813.16 BC 812.66 TC 813.00 BC 812.50 TC 809.49 BC 808.99 TC 809.88 BC 809.38 TC 809.32 BC 808.82TC 809.32 BC 808.82 TC 809.78 BC 809.28 TC 809.72 BC 809.22 TC 809.48 BC 808.98 TC 810.27 BC 809.77 808.82 808.82 809.03 809.22 812.32812.08 TC 812.47 BC 811.97 TC 813.47 BC 812.97 TC 812.25 BC 811.75 TC 813.23 BC 812.73 TC 809.25 BC 808.75 TC 809.93 BC 809.43 TC 809.93 BC 809.43 TC 809.40 BC 808.90 809.58 809.27 809.18 811.11 810.77 810.47 809.46 812.48 MEG 813.09 812.98 812.95 TC 813.34 BC 812.84 813.02 813.36 810.45 810.35 810.35 810.12 809.98 810.00 MEG 809.87 MEG 809.42 MEG 808.88 MEG 807.18 MEG 806.75 MEG 808.01 MEG 809.54 809.00 808.13 807.30 807.00 817.34 MEG APPROXIMATE LIMITS OF DISTURBED AREA UNDERGROUND DETENTION BOTTOM OF CHAMBERS = 801.25 TOP OF CHAMBERS = 806.25 10 YEAR ELEV. = 803.72 100 YEAR ELEV. = 806.04 6 6 6 6 BENCHMARKS: 30 900 30 60 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what'sbelow. before you dig.Call R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! USGS BENCHMARK INFORMATION CONSULTANT PROJECT NUMBER: TLF-2020-266 CARMEL CLAY SCHOOLS PROJECT ISSUE DATE: 10.14.2020 DRAWN BY: HHW REV. NO. DESCRIPTION DATE TAC 10/14/2020A CONSTRUCTION DOCUMENTS WWW.FHAI.COM ARCHITECT 317-848-0966 350 E NEW YORK ST# 300, INDIANAPOLIS, IN 46204 COPYRIGHT 2020 BY FANNING/HOWEY ASSOCIATES, INC. CARMEL HIGH SCHOOL 520 E MAIN STREET CARMEL, IN 46032 PARKING LOT ADDITION 19700317 No. RESPONSE TO TAC COMMENTS 11/25/2020B RESPONSE TO TAC COMMENTS 12/29/2020C G2.1 GRADING PLAN 1. SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND. 2. TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE PROVIDED BY CIVIL ENVIRONMENTAL CONSULTANTS, INC. THE ENGINEER MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECT AREA INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND DEPTH PRIOR TO ANY OTHER SITE CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER. 4. SEE UTILITY PLAN, SHEET SU1.1 FOR STORM SEWER DATA TABLE. 5. THE PROPOSED STORM SEWER SYSTEM FOR THIS PROJECT WILL BE PRIVATE OWNED. 6. FLOOD ROUTING PATH FROM PARKING LOT WHEN 100 YEAR FLOOD IS EXCEEDED. PATH TRAVELS IN A NORTHERLY DIRECTION TO EXISTING INLETS LOCATED ON THE NORTH SIDE OF BRIDGE OVER COOL CREEK. 7. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 8. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPERS RESPONSIBILITY TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. 9. DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. GENERAL NOTES GRADING PLAN LEGEND EXISTING SPOT ELEVATION MATCH EXISTING GRADE TOP OF CURB BOTTOM OF CURB EXISTING CONTOUR W/ ELEVATION PROPOSED CONTOUR W/ ELEVATION PROPOSED SPOT ELEVATION PROPOSED CURB ELEVATION PROPOSED SURFACE DRAINAGE FLOW ARROW FLOOD ROUTING PATH MEG TC BC TC BC 750.65 DETENTION SUMMARY ALLOWABLE RELEASE RATES CONTRIBUTING AREA 10 YEAR (0.1 CFS/ACRE) 100 YEAR (0.3 CFS/ACRE) 1.22 ACRES 0.12 CFS 0.36 CFS PROPOSED CONDITIONS STORM EVENT RESTRICTED RELEASE RATE STORAGE VOLUME 10 YEAR 0.12 CFS 0.271 AC/FT 100 YEAR 0.36 CFS 0.445 AC/FT 100 YEAR INLET CASTING CAPACITY ELEVATION TABLE STRUCTURE NUMBER 100 YEAR ELEVATION (INLET 50% CLOGGED) 101 R-3472 NEENAH INLET CASTING TYPE 809.00 TOP OF CASTING ELEVATION 809.29 102 R-3472 812.50 812.76 R-3472 808.60 808.89 R-3472 808.60 808.90 R-3472 812.00 812.25 R-3472 811.50 811.75 103 104 105 106 ALL OF THE 100 YEAR ELEVATIONS SHOWN IN THIS TABLE ARE BELOW ALL TOP OF CURB ELEVATIONS IN THE PROPOSED PARKING LOT. THE TOTAL STORAGE VOLUME PROVIDED IN THE PROPOSED DETENTION SYSTEM IS 0.501 AC/FT. INDICATES APPROXIMATE LIMITS OF 100 YEAR ELEVATION OF INLET 50% CLOGGED 07/21/21