HomeMy WebLinkAbout0670.02 Plot Plan A
,`oEiri
``QPV., CONSULTING ENGINEERS
co / s` JOB b DTR.78
9`, `�� LAND SURVEYORS CONTROL # 44087 HESS
'ociate`-' 9940 Allisonville Rd.•Fishers, IN 46038
(317) 849-5935 • 1-800-728-6917 • FAX: (317) 849-5942
13293 MOHICAN COURT
COMMON AREA `.- E 54.3
BLOCK "B" P 54.3
VAR. D.U.&S.E. 151.87
_-
---7
10' D.U.&S.E• `
/ /
E 55.0
P 55.0 '
''''.... 14411 ,,,. .....%„
/
/ END SECTION
c
rn
kn. t
1" = 30''
/
LOT AREA: 25,345 Sq. Ft.
to
o
IiIo
0
C\j
I U E 54.3
► P54.3
E 57.0 / E 56.1
P 57.0 P 57.6 49.33 W I E 55.1 41
4i P57.6I ,
17.33 .D
(D a
Iv
v I 2. . I F.F.ELEV.=961.60 w
F'P
.P. o '
35.3' BSMT.=952.60 N
0
co
30.0' 0 0
GAR. E 55 8 I
' P 60.1
CONC.-VI960.43 0 0 0 3.35 0 4. LEGEND:
DRIVE 3 17 9 Op 15.17 0 1g.4' E 99.99 EXISTING GRADE (BEFORE CONST.)
9' 5.29 E 55.8 P 99.99 PROPOSED GRADE (AFTER CONST.)
/ 22.00 °' I PORCH 2.19-NT P 58.0
I �w ' - - - - - -SUB-SURFACE DRAIN
4'SW ' SANITARY SEWER
E 56.8 STORM SEWER
P 60.1
I / W WATER MAIN
' / W 3/4" WATER CONNECTION
E 57.0
P 58.8 N 40' B.L. I o
,...„ZrI • SEWER MANHOLE
14.0' I c /
E 56.5 STORM MANHOLE
4 J P 58.5 J
II 0 31 ■ CURB INLET
T.C.=759.60E 20' D.U.&S.E.
- - - �"� FIRE HYDRANT
.-----
E -� 9�p
57.2
P 59.3 Ik / _
37.53 4'SW 6 1 I , T.C.=759.00±
i
L Z1=======111%-----
ALL UNDERGROUND SEWERS AND UTILITIES
• NMOHICAN COURT P 78.43 SHOWN ARE PLOTTED BY SCALE FROM
DESIGN PLANS FURNISHED BY ENGINEER
- - 38' RAD THE ACTUAL FIELD LOCATION MAY VARY.
P 59.05
Pir
N 40
V.M4 141111rAdi IIIIIW
TYPICAL SWALE DETAIL
I NOT TO
0 SCALE
I-
J
ci
No.
LOT 78 - 80040348
DELAWARE TRACE STATE OF
SECTION 4 ,14,-..�'°'""*. 40
,,,,�0 SURvs`���.,
INST.#200000035110 i►►►
P.C.#2, SLD.#455
ZONING: S-1 s,44'
10' MIN. SIDE YARD & 30' AGG.
20' MIN. REAR YARD
06/1 4/02 BSI)
"HOLEY MOLEY SEZ"
"DON'T DIG BLIND"
CALL TWO WORKING DAYS BEFORE YOU DIG.
IT'S THE LAW
,A7 ...
1-800-382-5544
nor
BUILDING PERMIT INFORMATION
CARMEL-CLAY TOWNSHIP
Department of Community Services
If the information required (listed below) is insufficient, it will
extend the time it takes to get an approved building permit.
CARMEL ZONING ORDINANCE Z-289, SELL ION 29.4.2(3): The Director, Department of Community Services (or staff)
shall approve or deny the improvement location permit (building permit) within five (5) working days of the receipt of the
written application form and accompanying materials. The improvement location permit (building permit) shall be issued
when the proposed structure, improvement or use and its location conform in all respects to this ordinance.
The following must be received by the Department of Community Services before any _.ilding or remodeling permit can
be reviewed or issued by staff:
1. ONE completed Improvement Location Permit (Building Permit) application.
2. TWO (2) complete sets of construction plans. Building elevations, foundation plan, floor plan and typical
wall section must be shown. All cross-sections must be properly detailed and labeled. At lease one
cross-section must show R-values of building materials to ensure compliance with the Indiana Energy
Codes. If minimum R-values are not met on cross-section an Energy Code Compliance Worksheet must
be completed. If manufactured trusses are used, a diagram must be included with building plans for all
trusses being used. Truss diagrams must be stamped with the seal of the registered architect or
engineer who is responsible for that design. Only Indiana registrations will be recognized. If a
commercial construction, plans must be stamped approved by the Indiana State Department of Fire
Prevention & Building Safety. Indicate total height of building on plans.
3. ONE copy of sewer permit (from City of Carmel Engineering Dept., Hamilton Western Utilities or Clay
Regional Sewer District whichever applies), or septic permit (Hamilton County Health Department).
4. ONE (1) copy of plot plan from subdivision development plan.
5. TWO (2) copies of a site plan or plot plan showing the following REQUIRED information (can be obtained
from the landowner or developer):
--Name and address of designer of plan with date
--Name and address of owner
--Lot number and subdivision or applicable general description
--Lot drawn to scale -- all dimensions
--Scale and north arrow
--Lot/Property lines
--Minimum front building setback line per approved development plan (include all front yard)
--All roads, alleys, rights-of-way, etc.
--All other utilities and drainage rights-of-way and easements
--Any applicable flood plain area (Elevation Certificate if necessary)
--Building pad elevation and lot corner elevations
--All accessory buildings -- existing or proposed
--All sidewalks and driveways
--Sewer and water lines, septic system (tanks &filed system) and well location
--Drainage flow arrows
--All drainage swales and subsurface facilities (retention/detention areas, etc.)
--Sump pump (sump pump pits) showing discharge locations
--Geothermal heat pump discharge locations
If land is not within a platted subdivision, a legal description is needed.
ALL CONSTRUL I ION IS SUBJECT TO FIELD INSPEL I ION