HomeMy WebLinkAbout0673.02 Building File Report 10%
'14141 S1C1H1ULL1E1R
BUILDING FILE REPORT
Builder's File:TIPTON.BLG Date: May 31 2002 Page 1
Builder Information
Home Builder Name: DAVIS HOMES
Model Name or Number TIPTON
Development Name: EMERALD CREST
Property Address: 5758 AQUAMARINE DRIVE LO'r# 102
Energy Analysis Info
Insulation Contractor Name: Overhead Door Insul. Div.
Telephone Number. (317)842-7444
Building Plan Date: 01 /01 /02
General Design Characteristics
House Type: Two Stories
Foundation Type: Slab
Conditioned Floor Area: 3741.00
Number of Bedrooms: 4
Conditioned Floor Area Over Garage: 9.00% Of Total Floor Area
Heated First Mid Second Third
Basement Level Level Level Level
Distribution of Cond Floor Area(%) 46.0 54_0
Heated First Mid Second - Third
Characteristics of Each Floor Basement Level Level Level Level
Number of Corners 14 4
Percent Open to Floor Above 8.0 0.0
Nominal Flat Ceiling Height 8,0 8_Q
Percent Cathedral Ceiling 0.0 0.0
Schuller Ir terr>atanai,Inc.Big Insulation Division P.D.Sax 5105 Denver.CO dC1217-5103-
For Inforrnaiorl on the Performance Home Total Insulation Systrsn,call 1-8OD-054.31a3.
This Information does mot constitute arty warranty of energy cast or savirtgs-
REM/GMd v2.33(0)1 @86 Architectural army Corporation,Boulder,CO.
iiip
BUILDING FILE REPORT
TIPTON.BLG Page 2
Building Envelope Characteristics
Insulation Level Baseline
Ceiling(Attic Above): 38.0
Cathedral Ceiling: 38.0
Rim/Band Joist 13.0
Frame Wali(Frarne Cavity): 13.0
Frame Wall(Continuous): 4.4
Masonry Wall: 0.0
Foundation Wall(Cavity): 0.0
Foundation Wall(Continous): 10.0
Frame Floor, 19.0
Duct: FLEX DUCT R 5
Infiltration Rate(ACH): 0.75
Wall Construction Type: Frame
Window Type Double-Vinyl
Window U-Value: 0_48
Window SHGC: 0.57
Window Area(excluding fnd walls): 399.0 square feet
Number of Non-Glass Exterior Doors: 2
Average Slab Depth Below Grade
Basement: 0.0
First Level: 1.0
Mechanical Systems Characteristics - -- —Heating System Type: Fuel-fired air distribution
Heating Fuel Type: Gas
Cooling System Type: Air conditioner
Duct Location: Attic-under insul
Domestic Hot Water Fuel Type: Gas
Schuller International,Inc.Building Insulation Division P.0_Box51a Dower,C080217-51t58.
For information on the Performance Home Total'mutation System,call 1 3103.
This inrormahon does rrot constitute any warranty of energy cost or se+rmgs.
REM/Gold v2.XJ(c)1996 Architectural Energy Corporation,Boulder,CO_
�� ��ti��� rr.
�• . � S1C1H1UjL1LIER
ft6/
1993 MEC OVERALL BUILDING Uo COMPLIANCE
Date: May 31 2002 Building File: TIPTON.BLG
Home Builder. DAVIS HOMES Weather Site: Indianapolis,IN
Model Name or Number. TIPTON Degree Days, H/C: 5853/378
Insulation Contractor: Overhead Door Insul. Div. Energy Costs: Indiana Gas
Contractor's Telephone: (317)842-7444
Elements Insulation Levels
1993 MEC As Designed
RoofsiCeilings(U-Value) 0.028 0.025
Above-Grade Walls (U-Value): 0.131 0.114
Floors Over Garage(U-Value): 0.050 0.048
Basement Walls(U-Value): 0.088 0.081
OVERALL Uo: 0.087 0.077
This home meets the overall thermal performance requirements of the 1993 Model Energy Code
based on 5653 heating degree-days. (Section 502, Model Enemy Code, 1993 edition).
Building Elements Cavity Ins. Contin. Ins Frame
R-Value R-Value Spacing uo Area
Roof/Ceilings
Roof 38.0 0.0 24.0"o.c. 0_025 2057.6
Above-GradeWalls
Wall 13.0 4.4 Wood, 2x4, 16" o.c. 0.057 2445.8
Joist 13.0 0.0 n/a 0.061 196.7
Window n/a n/a n/a 0.480 99.8
Window n/a n/a n/a 0.460 99.8
Window n/a n/a n/a 0.460 199.5
Door n/a 2.0 n/a 0.372 40.0
Frame Floors Over Garage
Floor 19.0 n/a 18.0" o.c. 0.048 336.7
Basement Walls
Wall 0.0 10.0 None 0,081 196.7
Schuller InEarnr3tlor)aI.Inc.Building Insulation Division P_O_Boa 5103 Denver,CO 90217-5105.
For Information on the Performance Hama Total Insulation Sim,coil 1 4.3103.
This lnrormation does not oonsiitrte any warranty of energy cost or Savings.
REWGold v2.33(c)1996 Architectural Energy Corporation,Boulder,CO.