Loading...
HomeMy WebLinkAbout0673.02 Building File Report 10% '14141 S1C1H1ULL1E1R BUILDING FILE REPORT Builder's File:TIPTON.BLG Date: May 31 2002 Page 1 Builder Information Home Builder Name: DAVIS HOMES Model Name or Number TIPTON Development Name: EMERALD CREST Property Address: 5758 AQUAMARINE DRIVE LO'r# 102 Energy Analysis Info Insulation Contractor Name: Overhead Door Insul. Div. Telephone Number. (317)842-7444 Building Plan Date: 01 /01 /02 General Design Characteristics House Type: Two Stories Foundation Type: Slab Conditioned Floor Area: 3741.00 Number of Bedrooms: 4 Conditioned Floor Area Over Garage: 9.00% Of Total Floor Area Heated First Mid Second Third Basement Level Level Level Level Distribution of Cond Floor Area(%) 46.0 54_0 Heated First Mid Second - Third Characteristics of Each Floor Basement Level Level Level Level Number of Corners 14 4 Percent Open to Floor Above 8.0 0.0 Nominal Flat Ceiling Height 8,0 8_Q Percent Cathedral Ceiling 0.0 0.0 Schuller Ir terr>atanai,Inc.Big Insulation Division P.D.Sax 5105 Denver.CO dC1217-5103- For Inforrnaiorl on the Performance Home Total Insulation Systrsn,call 1-8OD-054.31a3. This Information does mot constitute arty warranty of energy cast or savirtgs- REM/GMd v2.33(0)1 @86 Architectural army Corporation,Boulder,CO. iiip BUILDING FILE REPORT TIPTON.BLG Page 2 Building Envelope Characteristics Insulation Level Baseline Ceiling(Attic Above): 38.0 Cathedral Ceiling: 38.0 Rim/Band Joist 13.0 Frame Wali(Frarne Cavity): 13.0 Frame Wall(Continuous): 4.4 Masonry Wall: 0.0 Foundation Wall(Cavity): 0.0 Foundation Wall(Continous): 10.0 Frame Floor, 19.0 Duct: FLEX DUCT R 5 Infiltration Rate(ACH): 0.75 Wall Construction Type: Frame Window Type Double-Vinyl Window U-Value: 0_48 Window SHGC: 0.57 Window Area(excluding fnd walls): 399.0 square feet Number of Non-Glass Exterior Doors: 2 Average Slab Depth Below Grade Basement: 0.0 First Level: 1.0 Mechanical Systems Characteristics - -- —Heating System Type: Fuel-fired air distribution Heating Fuel Type: Gas Cooling System Type: Air conditioner Duct Location: Attic-under insul Domestic Hot Water Fuel Type: Gas Schuller International,Inc.Building Insulation Division P.0_Box51a Dower,C080217-51t58. For information on the Performance Home Total'mutation System,call 1 3103. This inrormahon does rrot constitute any warranty of energy cost or se+rmgs. REM/Gold v2.XJ(c)1996 Architectural Energy Corporation,Boulder,CO_ �� ��ti��� rr. �• . � S1C1H1UjL1LIER ft6/ 1993 MEC OVERALL BUILDING Uo COMPLIANCE Date: May 31 2002 Building File: TIPTON.BLG Home Builder. DAVIS HOMES Weather Site: Indianapolis,IN Model Name or Number. TIPTON Degree Days, H/C: 5853/378 Insulation Contractor: Overhead Door Insul. Div. Energy Costs: Indiana Gas Contractor's Telephone: (317)842-7444 Elements Insulation Levels 1993 MEC As Designed RoofsiCeilings(U-Value) 0.028 0.025 Above-Grade Walls (U-Value): 0.131 0.114 Floors Over Garage(U-Value): 0.050 0.048 Basement Walls(U-Value): 0.088 0.081 OVERALL Uo: 0.087 0.077 This home meets the overall thermal performance requirements of the 1993 Model Energy Code based on 5653 heating degree-days. (Section 502, Model Enemy Code, 1993 edition). Building Elements Cavity Ins. Contin. Ins Frame R-Value R-Value Spacing uo Area Roof/Ceilings Roof 38.0 0.0 24.0"o.c. 0_025 2057.6 Above-GradeWalls Wall 13.0 4.4 Wood, 2x4, 16" o.c. 0.057 2445.8 Joist 13.0 0.0 n/a 0.061 196.7 Window n/a n/a n/a 0.480 99.8 Window n/a n/a n/a 0.460 99.8 Window n/a n/a n/a 0.460 199.5 Door n/a 2.0 n/a 0.372 40.0 Frame Floors Over Garage Floor 19.0 n/a 18.0" o.c. 0.048 336.7 Basement Walls Wall 0.0 10.0 None 0,081 196.7 Schuller InEarnr3tlor)aI.Inc.Building Insulation Division P_O_Boa 5103 Denver,CO 90217-5105. For Information on the Performance Hama Total Insulation Sim,coil 1 4.3103. This lnrormation does not oonsiitrte any warranty of energy cost or Savings. REWGold v2.33(c)1996 Architectural Energy Corporation,Boulder,CO.