Loading...
HomeMy WebLinkAboutM002.0Indianapolis Design Center352 South County Road 300 EDanville, IN  46122317-745-9984These placement plans have been prepared with the specifications of TrussJoist products based on project information provided. This service is solely intendedfor product application assurance; and, is not intended to circumvent the needfor a design professional as determined by the building codes. The designerof record and/or builder/framer is responsible to assure these drawings arecompatible with the overall project. These documents are not intended to replacethe building plan (which should be used to determine bearing placement).Please insure measurements of the foundation match those provided at the timeof design.  Builder is responsible to place load bearing members in load path.Architectural Drawings Prepared By: Structural Drawings Prepared By: 84 Lumber FranklinKevin BeherPyatt BuildersTG87Rev. By Date CommentsDrawn By:DWChecked By: Date:CM 06/22/2021Marin 25143 Sheet 1 of 1 Main Floor System Not to Scale Confirm this layout with the builder and designer of record.  Make sure all discrepencies are corrected before ordering floor system. All Dimensions are Approximate and Must Be Field Verified. 11 7/8" TJI Joists 24" TJI Joists Framing Connector Summary PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff H1 1 Simpson IUS2.37/11.88 Designed 10- 10dx1.5 - 2- 10dx1.5 - - No No Yes H2 1 Simpson IUS3.56/11.88 Designed 12- 10d - 2- Strong-Grip - - No No No H3 2 Simpson MIU2.37/11 Designed 20- 10dx1.5 - 2- 10dx1.5 - - No No No H202 10 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- 10dx1.5 - - No No Yes H203 7 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- Strong-Grip - - 2 No No H204 6 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- Strong-Grip - - No No No H205 4 Simpson IUS2.37/11.88 Designed 10- 10dx1.5 - 2- Strong-Grip - - No No No Products PlotID Length Product Plies Net Qty FJ201 28' 0" 11 7/8" TJI 110 joist 1 8 FJ202 24' 0" 11 7/8" TJI 110 joist 1 4 FJ204 18' 0" 11 7/8" TJI 110 joist 2 2 FJ203 18' 0" 11 7/8" TJI 110 joist 1 1 FJ205 14' 0" 11 7/8" TJI 110 joist 1 2 FJ206 12' 0" 11 7/8" TJI 110 joist 1 10 FJ207 6' 0" 11 7/8" TJI 110 joist 1 4 FJ208 4' 0" 11 7/8" TJI 110 joist 1 1 FJ209 2' 0" 11 7/8" TJI 110 joist 1 1 FJ210 28' 0" 11 7/8" TJI 360 joist 1 1 FJ211 18' 0" 11 7/8" TJI 360 joist 1 9 BM201 22' 0" 1 3/4" x 18" 2.0E Microllam LVL 3 3 BM202 20' 0" 1 3/4" x 16" 2.0E Microllam LVL 3 3 BM203 14' 0" 1 3/4" x 11 7/8" 2.0E Microllam LVL 2 2 BM204 4' 0" 1 3/4" x 7 1/4" 2.0E Microllam LVL 2 4 BM205 18' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 Ca201 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 9 Blocking PlotID Length Product Plies Net Qty Bk201 2' 0" 11 7/8" TJI 110 joist 1 1  LEVEL NOTES  Current Date:  6/22/2021  File Name:  tg87_25143.jvl  Level Name:  Second Floor System  Building Code - Design Methodology:  IBC 2006  Members with Design Overridden:  TJ-Pro Rating (Weighted Average):  47     Minimum Level TJ - Pro Rating & Joist:  TJ-Pro rating = 31, joist = FJ203(i3476)     Maximum Level TJ - Pro Rating & Joist:  TJ-Pro rating = 57, joist = FJ206(i3534)  FLOOR  Floor Container:  FC2  Use/Occupancy:  ResidentialLivingAreas  Floor Area Loading is:  40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load  Operator Added Additional Loads  Maximum Allowed Deflection:  L/480 Live Load & L/240 Total Load  TJ-Pro Rating Information:      Weighted Average:  47      Directly Applied Ceiling:  Gypsum 1/2"      Decking Attachment:  Glue and Nail      Decking Material:  23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF      Perpendicular Partition:  No      Strapping at max 8' o.c.:  None      Blocking at max 8' o.c.:  No      Poured Flooring:  No CS CS CS B4 A3 A3 A3 A3 A3 A3 A3 H2 H2 H2 BM203BM204BM204BM202 BM201BM205 VO1 VO2 VO3 VO4 FJ211 FJ211 FJ211 FJ211 FJ206 FJ211 FJ206 FJ211 FJ206 FJ211 FJ206 FJ204 FJ206 FJ206 FJ203 FJ207 FJ205 FJ207 FJ205 FJ201 FJ201 FJ201 FJ201 FJ201 FJ201 FJ201 FJ201 FJ202 FJ202 FJ202 FJ202 FJ206 FJ206 FJ206 Ca201 Ca201 Ca201 Ca201 Ca201Ca201Ca201Ca201Ca201Ca201 Ca201 FJ207FJ209 Ca201H203 FJ207H203H203 H203 FJ208Ca201H203 FJ210 H202 H202 H202 H202 H202 H202 H202 H202 H202 H202 1' 0"2' 0" 2' 0"1' 0" FJ211 FJ206 FJ211 1' 0"2' 0" 2' 0" 2' 0" 1' 0" Bk201 H203 H203 H1 H3 H205 H204 H204 H205 H204 H204 H3 H204H205 H204 H2 H205 11 9/16"1' 5 7/16"1' 0 7/16"9 9/16"7' 10 7/8" 10' 5 3/4"5' 1 3/4"5' 1 1/8" 9' 9 3/4"3' 6 7/8"3' 6 7/8"Flush beam depth greater than floor joist depth. Verify all loading and framing conditions prior to construction. There are different joist series of the same depth specified on this floor system.  Verify when installing that the proper TJI® joists are used in the appropriate area. 7 1/2" bearing needed for joist connection. 07/28/21