HomeMy WebLinkAboutFoundation Plan 07-19-211
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
SHEET 2 OF 5
DRAWN
CHECKED
QA
MFG
APPROVED
BACON 4/18/2021
DWG NO
garage
TITLE
SIZE
D
SCALE
REV
POST AND FRAME BLDG
SIZE AND POST LOCATIONS
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
SHEET 3 OF 5
DRAWN
CHECKED
QA
MFG
APPROVED
BACON 4/18/2021
DWG NO
garage
TITLE
SIZE
D
SCALE
REV
FOOTER SECTION VIEW
6" MIN
CMU BLOCK BELOW
FROST LINE
4" REINFORCED
CONCRETE SLAB
4" TAMPED GRAVEL
PRO RIB CLASS 4
HAIT RESISTANCE
CLASS A FIRE
RESISTANCE PANEL
UNDISTURBED
EARTH UNDISTURBED
EARTH
BUILDING POST
CONCRETE POST FOOTER
n12" x 32" DEEP
S L O P E A W A Y F R O M B L D G T Y P .
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
SHEET 4 OF 5
DRAWN
CHECKED
QA
MFG
APPROVED
BACON 4/18/2021
DWG NO
garage
TITLE
SIZE
D
SCALE
REV
4" REINFORCED CONCRETE SLAB
26'-0"
38'-0"
CMU FOOTER AROUND SLAB.
THIS FOOTER IS FOR PREVENTING
FLOODING. THIS IS NOT LOAD BEARING.
CONCRETE PIERS TYP. 14
FOUNDATION AND FOOTER PLAN
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
SHEET 5 OF 5
DRAWN
CHECKED
QA
MFG
APPROVED
BACON 4/18/2021
DWG NO
garage
TITLE
SIZE
D
SCALE
REV
16'-0" A.F.C.
4"
12"
EAST ELEVATION VIEW
24'-0"
12'-0"