A102 Reflected Ceiling Plan
CEILING PLAN LEGEND GENERAL CEILING PLAN NOTES 1. REMOVE EXISTING SWITCHES THAT ARE NOT RE-USED. REMOVE CONDUIT AND WIRING BACK TO NEAREST BASE BUILDING JUNCTION BOX. PATCH AND REPAIR WALL FOR NEW FINISH. 2. THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING HEIGHTS AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING, AND OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT INDICATED. ANY DISCREPANCY SHALL BE BROUGHT TO THE DESIGNER'S ATTENTION PRIOR TO PERFORMING ANY WORK. 3. CEILING HEIGHT THROUGHOUT THE SPACE IS 10'-0" A.F.F., UNLESS NOTED OTHERWISE. 4. EXISTING CEILING GRID AND ACOUSTICAL TILE TO REMAIN, UNLESS NOTED OTHERWISE. CONTRACTOR TO REMOVE AND REPLACE ANY EXISTING CEILING TILES AND CEILING GRID THAT IS BROKEN, CHIPPED, OR PUNCTURED WITH NEW TO MATCH EXISTING. 5. ALL NEW SWITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT CENTER OF SWITCH 6"-9" FROM EDGE OF DOOR FRAME, UNLESS NOTED OTHERWISE. MOUNT 48" A.F.F. TO CENTER OF DEVICE. 6. EXIT SIGNS, DOWN LIGHTS, SPRINKLER HEADS, ETC. SHALL BE CENTERED WITHIN TILE, UNLESS NOTED OTHERWISE. 7. COLOR OF LIGHT SWITCH DEVICES AND COVERPLATE TO BE BUILDING STANDARD, UNLESS NOTED OTHERWISE. 8. ALL MULTIPLE SWITCH LOCATIONS TO BE GROUPED TOGETHER AND LABELED WITH A SINGLE DEVICE COVERPLATE. 9. REFER TO ENGINEERING DOCUMENTS FOR INFORMATION, LOCATION AND SPECIFICATIONS ON EXIT SIGNAGE, LIFE SAFETY SYSTEMS, 24 EMERGENCY LIGHTING, VENTILATIONS, HVAC SYSTEMS, CIRCUITING OF LIGHTS AND THERMOSTAT LOCATION ETC. 10. THERMOSTATS SHALL BE LOCATED DIRECTLY ABOVE OR ADJACENT TO LIGHT SWITCH. ALL THERMOSTAT POSITIONS AND LOCATIONS TO BE COORDINATED WITH THE DESIGNER BEFORE PLACEMENT. 11. SUPPLY AND RETURN AIR GRILLES ARE TO BE FLUSH WITH NEW CEILING TILES AND ARE TO BE BLACK IN COLOR. REFER TO ENGINEERING DOCUMENTS FOR ADDITIONAL INFORMATION. 12. ALL DIMENSIONS ARE TO THE CENTERLINE OF FIXTURE, UNLESS NOTED OTHERWISE. 13. IF REQUIRED, ALL CEILING MOUNTED EQUIPMENT LOCATIONS TO BE COORDINATED WITH THE DESIGNER PRIOR TO INSTALLATION. 14. IF PRESENT, VERIFY ALL SPRINKLER HEAD LOCATIONS. NOTIFY DESIGNER IF ANY DISCREPANCIES OCCUR. 15. PROVIDE FIRE DAMPERS AT FIRE-RATED PARTITIONS AS REQUIRED PER APPLICABLE BUILDING CODES. 16. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DUCTWORK, SUPPLY AND RETURN AIR AND THERMOSTATS. COORDINATE ALL ELEMENTS OF THE HVAC SYSTEM TO PROVIDE A COMPLETELY BALANCED AND EFFICIENT HEATING AND COOLING SYSTEM. 17. HVAC THERMOSTAT CONTROL FOR ALL ROOMS SHALL BE LOCATED WITHIN DEMISED SUITE. VERIFY AND REWORK EXISTING DUCTWORK AND THERMOSTATS AS REQUIRED. 18. MECHANICAL CONTRACTOR SHALL VERIFY WORKING CONDITION OF ALL EXITING THERMOSTATS, VAV BOXES, EXHAUST FANS, AND ANY OTHER DEVICE DIRECTLY RELATED TO THE HVAC SYSTEM. CONTRACTOR TO NOTIFY ENGINEER/DESIGNER IMMEDIATELY UPON DISCOVERY OF DEFECTIVE DEVICE. 19. ALL JUNCTION BOX STEM EXTENSIONS, SUSPENDED MOUNTING HARDWARE, AND SIMILAR SHALL BE BLACK UNLESS OTHERWISE INDICATED. LAY-IN CEILING RETURN GRILLE SUPPLY DIFFUSER EXIT SIGN R: DENOTES RELOCATED FIXTURE ALL OTHER FIXTURES ARE NEW AS INDICATED. ALL OTHER DEVICES NOT TAGGED ARE EXISTING TO REMAIN. LIGHT SWITCHS RECESSED CAN LIGHT LIGHT FIXTURE LEGEND 4" RECESSED LED ROUND, DIMMABLE, 3500K (VENDOR; ESL SPECTRUM) CRATE & BARREL 28" DRUM PENDANT, "FINLEY LARGE WHEATE PENANT LIGHT", SKU416077 (www.crateandbarrel.com) 10" TALL PENDANT, SCOTT ARCHITECTURAL LIGHTING, S2840 SERIES, S2840-L15-35K-GT-WH-BKO (VENDOR: ESL SPECTRUM) IMBRIE ARTICULATING SCONCE, #B6957 SHADE AND #A6518 BASE, OIL RUBBED BRONZE FINISH (www.rejuvenation.com) EMERGENCY EGRESS LIGHTS WITH BATTERY BACKUP TO BE REUSED/RELOCATED 10" MEDIUM GLOBE PENDANT, Y LIGHTING "ASTRO GLOBE MINI PENDANT", BLACK CANOPY AND STEM (https://www.ylighting.com/astro-globe- mini-pendant-light-by-andrew-neyer- ANDP205659.html) NOTE: STEM EXTENSION FOR JUNCTION BOX WILL BE REQUIRED TO INSTALL AT DESIRED HEIGHT NOTED ON INTERIOR ELEVATIONS. F1 F2 F3 F4 F5 X1 F6 CYPRESS ARTICULATING SCONCE, #A6511, BRASS AND WHITE FINISH (www.rejuvenation.com) EMERGENCY LIGHT DRUM PENDANT FIXTURE GLOBE PENDANT FIXTURE CONE PENDANT FIXTURE WALL SCONCE 10' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" CHARCOAL, 90%, BLACK, MATTE BUILT-IN STRUCT. (TO FRAME RESOURCE WALL) 10' - 0"13' - 9 5/32"1' - 6" 1' - 6"1' - 6"5' - 7" EQ. 7' - 0" 7' - 0" EQ. 1' - 4" 4' - 0" WOOD SLAT CEILING (STARTS CL OF ISLAND) ARMSTRONG WOODWORKS, SUBMIT FINISH SAMPLE FOR APPROVAL (EXPOSED) F1 F1F1 F1F1 F1 F1 F2 F3 F3 F3 F4 F4 F5 F6 X1 $$11' - 9" 8' - 9"0' - 9 15/32"175.00°6' - 2 7/8"MULTI-FUNCTION PROGRAMMABLE KEYPAD FOR LIGHTING, SOUND, AND WINDOW SHADE CONTROL (FOUR-ZONE CONTROL) MULTI-FUNCTION PROGRAMMABLE KEYPAD FOR LIGHTING, SOUND, AND WINDOW SHADE CONTROL (FOUR-ZONE CONTROL) S S S S S S SPEAKER, BLACK, TYP. OF (6), MOUNT ABOVE WOOD SLAT CEILING HEIGHT 0' - 1"MOTORIZED WINDOW SHADES, MATCH BUILDING STANDARD (+/-90% BLOCKING BLACK), CONTROL WITH PROGRAMMABLE CONTROL PANEL. PROVIDE HARD WIRE POWER TO EACH CONTROL BOX STATE OF No. AR11700002JOSEPHE.LE SERE G I STERE DREGI ST ERED A R C H ITECTINDIA N A SHEET NUMBER SHEET TITLE DRAWN BY: REVIEWED BY: PROJECT NUMBER NO. DATE DESCRIPTION CERTIFICATION PREPARED FOR PROJECT ©2020 All Rights Reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or by any information retrieval system, without the permission of the copyright owner. Any unauthorized users will be prosecuted to the fullest extent of the law including any legal fees incurred by the copyright owner. IN ASSOCIATION WITH PROGRESS STUDIO, LLC 5915 N. College Ave., Suite 213 Indianapolis, IN 46220 317-978-1100 www.theprogressstudio.com -- 12/17/2020 OWNER REVIEW SET -- 02/14/2021 100% REVIEW SET -- 02/18/2021 STATE SUBMITTAL SET DELTA FAUCET COMPANY DESIGN RESOURCE CENTER 55 EAST 111TH STREET CARMEL, IN, 46280 TL JEL 20058 A102 REFLECTED CEILING PLAN 55 EAST 111TH STREET CARMEL, IN, 46280 3/8" = 1'-0" FIRST FLOOR NEW RCP1 07/30/21