Loading...
HomeMy WebLinkAboutC701 - STORM SEWER PLAN & PROFILEE EWWWWWWWWW W W WWW W W FDC WWWWWWWWWWWSSSSSSSSSSSSSSSSSSSTFRENCH DRAIN FOR HOLY WATERSCCE E E E EDSDSDSDSDSDSDSSTSTSTSTSTSTST DSEPTCCCCCCCCCCCCCCCCCCCCCC C709RIM=884.70705RIM=884.30707RIM=884.30704RIM=884.20708RIM=884.20706RIM=884.15713RIM=883.80726RIM=883.90702RIM=883.50711RIM=884.46710RIM=883.30725RIM=883.30727RIM=883.00703RIM=883.20722RIM=882.46724RIM=882.44723RIM=882.60721RIM=882.12701RIM=881.8810' OF 12" RCP@0.20%17' OF 12" RCP@0.17%31' OF 12" RCP@0.13%12' OF 12" RCP@0.84%112' OF 12" RCP@0.67%37' OF 12" RCP@0.81%80' OF 12" RCP@0.63%71' OF 15" RCP@0.56%11' OF 15" RCP@0.91%8' OF 15" RCP@1.00%10' OF 12" RCP@0.48%69' OF 12" RCP@1.04%52' OF 12" RCP@0.36%712RIM=883.60100 YR = 880.5210 YR = 878.9941' OF 12" RCP@0.73%EX 750RIM=883.36STR. #702 INLET F; R-3405RIM: 883.50INV. OUT 879.35 (12" RCP (NW))STR. #701 EXISTING CURB INLETRIM: 881.88INV. IN 878.63 (12" RCP (SE)) 69' 1.04% 12" RCPSTR. #705 INLET F; R-4215-C (INSTALL INLET OVER EXISTING PIPE)RIM: 884.30INV. OUT 881.00 (12" RCP (N))STR. #704 INLET F; R-4215-C (INSTALL INLET OVER EXISTING PIPE)RIM: 884.20INV. IN 880.90 (12" RCP (S))INV. OUT 879.50 (12" RCP (NW)) STR. #703 EXISTING INLET F; R-3405 (RAISE & REPLACE CASTING) RIM: 883.20 INV. IN 878.75 (12" RCP (SE)) 112' 0.67% 12" RCP 12' 0.84% 12" RCPSTR. #709 MH 4' DIA.;R-1772 (RAISE & REPLACE CASTING) RIM: 884.70 INV. OUT 880.50 (12" RCP (W)) STR. #708 MH 4' DIA.; R-4342 RIM: 884.20 INV. IN 880.48 (12" RCP (E)) INV. OUT 880.48 (12" RCP (W)) STR. #707 MH 4' DIA.; R-4342 RIM: 884.30 INV. IN 880.45 (12" RCP (E)) INV. OUT 880.45 (12" RCP (NW)) STR. #706 MH 4' DIA.; R-4342 (INSTALL MANHOLE OVER EXISTING PIPE) RIM: 884.15 INV. IN 880.41 (12" RCP (SE)) INV. 878.53 (EXISTING)(CORE/DRILL) 10' 0.20% 12" RCP 17' 0.17% 12" RCP 31' 0.13% 12" RCPSTR. #712 INLET F; R-4215-C RIM: 883.60 INV. OUT 880.50 (12" RCP (N)) STR. #EX 750 EXISTING MH RIM: 883.36 INV. IN 880.31 (12" RCP (S)) 52' 0.36% 12" RCPC701DRAWING TITLE:CERTIFIED BY:DRAWING NUMBERPROJECT NUMBERREVISIONS:SCOPE DRAWINGS:PROJECT: These drawings indicate the general scope of the projectin terms of architectural design concept, the dimensions ofthe building, the major architectural elements and the typeof structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe allwork required for full performance and completion of therequirements of the Contract. On the basis of the general scope indicated or described,the trade contractors shall furnish all items required for theproper execution and completion of the work.ISSUE DATEDRAWN BYCHECKED BY© 2018 CSO Architects, Inc. All Rights ReservedKnow what'sbelow.before you dig.Call2021-06-04SOMKPARISH LIFE CENTER PROJECT OUR LADY OF MT. CARMEL CHURCH 14598 OAK RIDGE RD, CARMEL, IN 4603219038 1. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTIONTO CONFORM TO APPLICABLE LOCAL AND STATESTANDARDS.2. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BEPERFORMED IN COMPLIANCE WITH APPLICABLE 0.S.H.A.STANDARDS FOR WORKER SAFETY.3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO FIELDVERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTIONBEGINS.4. CONTRACTORS SHALL MINIMIZE DAMAGE TO EXISTINGTREES.STORM SEWER PLANSTORM SEWER PROFILESCALE:HORZ.: 1"=30'VERT.: 1"=3'GENERAL NOTESLEGENDExisting GradeNew GradeGranular BackfillSCALE: 1" = 30'STRC 702-701STRC 705-703STRC 709-706STORM SEWERPLAN &PROFILESTRC 712-EX 750