HomeMy WebLinkAboutS100.0 - NVL 320 Main Level FLoor PlanW.C. L.UP17 EQUAL RISERSDOWN17 EQUAL RISERSFORMAL DINING - 9'0" CEILING KITCHEN - 9'0" CEILING - KITCHEN LAYOUT T.B.D. INFORMAL DINING - 9'0" CEILING SITTING AREA - 9'0" CEILING SCREEN PORCH 3 CAR GARAGE 2" MINIMUM SLOPED CONCRETE SLAB - CONCRETE PANTRY - 9'0" CEILING POWDER ROOM- 9'0" CEILINGENTRY FOYER - 9'0" CEILING COVERED PORCH LAUNDRY ROOM - 9'0" CEILINGSERVICE ENTRY- 9'0" CEILINGCOAT CLOSETPLAY ROOM - 9'0" CEILING PATIO DESIGN AS PER LANDSCAPE DESIGNER COAT CLOSET 6 GAS BURNER RANGE VENT HOOD TO EXTERIOR SINK DW. REF.BUTLER'S PANTRY- 9'0" CEILING10'0"x8'0" OVERHEAD DOOR 10'0"x8'0" OVERHEAD DOOR 10'0"x8'0" OVERHEAD DOORHANDRAIL3 STEPS DOWN SLOPE CEILING SLOPE CEILING OPEN TOABOVEW. D. CANTILEVERED SECOND FLOOR 4'-0"2'-1" 4'-6"10'-0"SINKW.C. DROPPED HEARTHHEAT N GLO8000 CLXFIREPLACEGRANITE FIREPLACE SURROUND GUEST BEDROOM BATHROOM - 9'0" CEILING WALK-IN CLOSET WALK-IN CLOSET STUDY - 9'0" CEILING - 9'0" CEILING - 9'0" CEILING - 9'0" CEILING GALLERY - 9'0" CEILING L. SHOWER CANTILEVERED SECOND FLOOR FREEZERNORTH SOUTH EAST WEST LIVING ROOM ROOF OVERHANG WINDOWSEAT3'0"x8'0" 14" SIDELIGHT 14" SIDELIGHT 2-PLYx117 8 LVL HEADER 2-PLYx117 8 LVL HEADER 2-PLYx1178 LVL HEADER3-PLYx18 FLUSH LVL HEADER W/ JST HANGERS 2-PLYx16 FLUSH LVL HEADER W/ JST HANGERS 2-PLYx117 8 LVL HEADER 2-PLYx16 FLUSH LVL HEADER W/ JST HANGERS 2-PLYx16 LVL HEADER2-PLYx14 LVL HEADER 16" FLOOR JST. DIRECTION16" FLOOR JST. DIRECTION1 8 1 8 2 8 2 8 3 9 3 9 4 94 9 5 5 3 PLY SOLID BLOCKING 3 PLY SOLID BLOCKING 3 PLY SOLID BLOCKING 3 PLY SOLID BLOCKING 3 PLY SOLIDBLOCKING3 PLY SOLID BLOCKING 3 PLY SOLID BLOCKING3'0 "x6 '8 " 3'0"x6' 8 " 2'8"x6' 8 "3'0 "x6 '8"3'0"x6'8"2'6 "x6 '8"7'0"x8'0"CASED OPENING2'8"x6 '8"3'0"x8'0"CASED OPENING8'0"x8'0" CASED OPENING 3'0"x8'0" CASED OPENING 3'0"x6'8" CASED OPENING w/ TRANSOM 3'0"x6'8" POCKET DOOR 3'0 "x6 '8 "3'0"x6'8"2'8 "x6'8 "PR. 3'0"x6'8"POCKET DOOR2'8"x8' 0 " 3'0"x8' 0"2060DHG2660DHG2660 CMT2026DHG3460 DHG3460 DHG3460 DHG3460 DHG3460 3460 3460 CMT3046 DHG3060 DHG3060 2'-411 16" 2'-7516" 19'-412" 10'-0" 2'-7 1 2" 4'-2 5 16" 1'-9 1116"5'-0" 2'-0" 32'-0" 6'-0" 2'-4"7'-9" 11'-7" 11'-7" 7'-9" 6'-734" 7'-014" 1'-0" 15'-5516" 1'-0"38'-8" 13'-8" 17'-5516"6'-41116" 6'-7516" 6'-101116" 7'-1516" 7'-1178" 11'-418" 7'-4" 5'-0" 5'-0" 5'-11" 12'-10" 5'-11" 13'-0" 14'-0" 26'-8" 10'-0" 24'-8" 2'-338" 1'-0" 9'-5" 1'-0" 12'-1158"6'-4" 4" 7'-9" 512" 6'-7" 312" 6'-012"3 12" 23'-11" 4" 2'-4" 1'-0" 13'-1516" 1'-0"13'-412"312" 38'-0" 4" 4"21'-1" 312"4'-1" 312" 13'-7"4" 4" 4'-1" 312" 7'-212" 312" 4'-1" 312" 15'-1" 4"3'-1"8'-1"312"14'-1" 4" 4" 14'-412"3 12" 23'-1012" 512" 24'-412" 312" 24'-0" 4" 4" 6'-81 2" 312" 5'-812" 312" 13'-812" 312" 3'-1134" 312" 7'-514" 5 12" 13'-10" 512" 9'-11" 312" 24'-0" 4" 7'-614" 7'-134" 12'-314" 12'-034" 2'-178" 2'-0" 7'-1014" 8'-614" 2'-3" 8'-758" 6'-7" 14'-8" 24'-4" 4'-178" 16'-412" 17'-558" 11'-4" DHG3460 DHG3460 3260-2 DHG3260DHG3260DHG3060DHG3060 4" 12'-6" 512" 6'-712"312" 3'-2" 312" 2'-112" 312" 5'-3" 312" 5'-1012" 312" 2'-1" 312" 2-PLYx914 LVL HEADER - CARPET FLOOR - WOOD FLOOR - TILE FLOOR - PAINT - INSULATE DRYWALL H.B. H.B. - CROWN MLDG. - WOOD FLOOR - CROWN MLDG. - WOOD FLOOR - WOOD FLOOR - WOOD FLOOR H.B. - BRUSHED CONCRETE - CAR SIDING ON CEILING - VAULTED CEILING - SMOOTH CEDAR FOR FINISHED TRIM - CROWN MLDG.10'0"x8'0"CASED OPENING- BLUESTONE SURFACE - CAR SIDING ON CLG. - WOOD STEPS - CARPET FLOOR - TILE FLOOR - TILE WALLS BUILT-IN BUILT-IN- WOOD FLOOR - CROWN MLDG. 10 10 6x6" POST (TYP.) 6x6" POST (TYP.) 6x6" POST (TYP.) 6x6" POST (TYP.)3-PLYx16 FLUSHLVL2-PLYx16 FLUSH LVL HEADER W/ JST HANGERS3-PLYx16 FLUSHLVL2'-4" 2'-8"2'-0 12"1'-834"2'-0 1 2"1' - 8 3 4 " 3'-3116" 3'-3116" 1'-0" 16'-558" 1'-0" 11'-21116" FIXED FIXED FIXED MICRO - WOOD FLOOR - TILE FLOORFIXED3'-1034" 312"3'0 " x 6 ' 8" - 9'0" CEILINGFIXED 3'0 "x6'8" Bomb e r Hi nge DHG3460 FIXED8060 DHG3460 2'-012"1'-712"3. GENERAL NOTES * 9'0" CEILING HEIGHT UNLESS OTHERWISE NOTED * POCKET DOORS: TRIPLE 2x12 HDR. W/ 12" PLYWD. GUSSETS 2 PLY SOLID BLK'G. BOTH SIDES (TYP.) BEARING WALLS 2. MATERIALS LEGEND CONSTRUCTION LEGEND FRAME WALLS 1. AREA LEGEND 3 CAR GARAGE: 925 SQ. FT. MAIN LEVEL: 2838 SQ. FT. MAIN LEVEL STONE VENEER * MAIN LEVEL FLOOR JOIST SYSTEM 60 LBS. P.S.F. TOTAL FLOOR LOAD * PROVIDE SOLID BLK'G. BETWEEN FLOORS UNDER ALL BEARING WALLS AND COLUMNS ABOVE * INTERIOR DIMENSIONS TO FACE OF STUD WALLS * EXTERIOR DIMENSIONS TO FACE OF SHEATHING * ALL WALLS ALIGNED WITH FLOOR JOIST DIRECTION TO HAVE FLOOR JOIST BELOW THEM * VERIFY WINDOWS w/ OWNER/CONTRACTOR. ANDERSEN WINDOWS SHOWN, VERIFY WINDOW NUMBERS AND SIZING WITH WINDOW MANUFACTURER AFTER THIS IS COMPLETE, PLEASE PROVIDE H.G. McCULLOUGH DESIGNERS WITH A WINDOW LIST * FLOOR JOIST MANUFACTURERS ARE TO SUPPLY H.G. McCULLOUGH DESIGNERS WITH ALL NECESSARY FLOOR FRAMING PLANS, INCLUDING MAIN LEVEL, SECOND LEVEL AND ROOF PLAN. H.G. McCULLOUGH DESIGNERS IS TO BE NOTIFIED DURING THE FLOOR FRAMING DESIGN PROCESS IF IT DEVIATES FROM THE ORIGINAL PLAN, AND REVIEW THE CHANGES WITH ONE ANOTHER. SECOND LEVEL: 2210 SQ. FT. SECOND LEVEL 2x10 BLOCKING FLUSH W/ INSIDE FACE OF STUDS 8" TRIPLE 2x12 w/ 1/2" SOLID PLYWOOD GUSSET HEADER 4. WINDOW/DOOR HEAD FRAMING DETAIL (TYP.)6"UNFINISHED: 695 SQ. FT. FINISHED: 1015 SQ. FT. LOWER LEVEL Date: 07-14-2021Plan number #201125Designed For:Futrell - StrupNVL 320H. G. McCULLOUGH DESIGNERS, INCCONSTRUCTION DRAWINGS BY:- 2146 Glenview Drive, Evansville, IN 47720 - Email: designers@hgmccullough.com- Telephone: 812 . 428 . 0174 - www.hgmccullough.comMake yourself at homeMcKENZIECOLLECTION.COM4631 Lisborn Drive Carmel, IN 46033317.574.7617 PSCALE: 1/4"=1'-0"MAIN LEVEL FLOOR PLAN "C 2002 H. G. McCullough Designers, Inc. All rights reserved There shall be NO reproduction of this work, its technical aspects or creative content without the express written consent of H. G. McCullough Designers, Inc. This work is fully protected by copyright under U.S. copyright law and is strictly enforced by H. G. McCullough Designer, Inc." 3Drawings & blueprints are intended solely as a plan layout& basis for materialestimate. H.G. McCullough Designers Inc.assumes no responsibility for structuralor material adequacy of drawings nor for compliance with appropriate building codes.H.G. McCullough Designers Inc. is not liable for, nor does it guarantee or controlcontractor or subcontractor's performance, nor their errors or omission. Customersshould have qualified engineer or architect review construction detailsSHEET NUMBER 08/03/21