Loading...
HomeMy WebLinkAboutA000_Cover SheetMERIDIAN STKEYSTONE AVEPEND L E T ON PIK E 38TH ST I-70 WASHINGTON STI-465I -465 I-65SMICHIGAN RDI-6 5 N I -70 ROCKV I L LE RD INDIANAPOLIS SITE LOCATION LOCATION MAP SCALE: N.T.S. CENTER LINE ABOVE FINISH FLOOR AIR CONDITIONER ALUMINUM BELOW FINISH FLOOR BUILDING CABINET CARPET CEILING CERAMIC TILE CLOSET COLUMN CONCRETE MASONRY UNIT CONTINUOUS DEMOLITION DETAIL DIAMETER DOWN DOWNSPOUT DRAWING ELEVATOR EQUIPMENT EXISTING EXTERIOR FEET FINISH FIRE EXTINGUISHER FLOOR DRAIN FOOTING GLASS, GLAZING GYPSUM HEIGHT HOLLOW CORE HOLLOW METAL INSULATION INTERIOR JUNCTION BOX LAMINATE LAVATORY MAXIMUM METAL MECHANICAL MINIMUM MIRROR CL AFF A/C ALUM BFF BLDG CAB CPT CLG CT CLO COL CMU CONT DEMO DTL DIA DN DS DWG ELEV EQUIP EXIST EXT FT FIN FE FD FTG GL GYP HT HC HM INSUL INT JB LAM LAV MAX MTL MECH MIN MIR NOT TO SCALE NUMBER ON CENTER OWNER FURNISHED/ OWNER INSTALLED OWNER FURNISHED/ CONTRACTOR INSTALLED CONTRACTOR FURNISHED/ CONTRACTOR INSTALLED PAINT PLUMBING PROJECT REINFORCEMENT REQUIRED REVISION ROUGH OPENING SIMILAR SOAP DISPENSER SIMULATED DIVIDED LITE SQUARE FEET STANDARD STAINLESS STEEL STEEL STORAGE TYPICAL URINAL WATER CLOSET WITHOUT WOOD NTS NO. O.C. OFOI OFCI CFCI PT PLBG PROJ REINF REQ REV RO SIM SD SDL SF STD SS STL STOR TYP UR WC W/O WD ELEVATION CERAMIC TILE MASONRY CONCRETE WOOD BRICK GLAZING SECTION EARTH CONT. WOOD/ BLOCKING WOOD BLOCKING SHEATHING INSULATION BOARD INSULATION RIGID INSULATION BATT INSULATION BRICK GYPSUM BD./ STUCCO CONCRETE STEEL ALUMINUM THIS PROJECT WAS DESIGNED USING THE FOLLOWING CODES: INDIANA BUILDING CODE, 2014 EDITION (IBC, 2012 EDITION, 1ST PRINTING) INDIANA FIRE CODE, 2014 EDITION (IFC, 2012 EDITION, 1ST PRINTING) INDIANA PLUMBING CODE, 2012 EDITION (IPC, 2006 EDITION) INDIANA ELECTRICAL CODE, 2009 EDITION (NFPA 70-2008) INDIANA MECHANICAL CODE, 2014 EDITION (IMC, 2012 EDITION, 1ST PRINTING) INDIANA ENERGY CONSERVATION CODE, 2010 (ASHRAE 90.1, 2007 EDITION, AS AMENDED) USE AND OCCUPANCY: GROUP A2 (RESTAURANT) OCCUPANT LOAD FACTOR: 100SF/ PERSON GENERAL BUILDING HEIGHTS AND AREAS: CONSTRUCTION TYPE: III-B ALLOWABLE (A2 -IA): ULSF, UL STORIES- UL FEET TENANT AREA: CONDITIONED 3,945 SF INDOOR/OUTDOOR PATIO 2,161 SF OUTDOOR PATIO 1,692 SF OCCUPANT LOAD: 296 PEOPLE (2 EXITS REQUIRED). 5 NET SF/PERSON - STANDING TOTAL NET SF OF AREA: 236 NSF 236 NSF/5 NSF = 48 OCCUPANTS 15 NET SF/PERSON - TABLES/CHAIRS TOTAL NET SF OF AREA: 2,001 NSF 2,001 NSF/15 NSF = 134 OCCUPANTS 2 FEET/PERSON - BAR SEAT LENGTH TOTAL LENGTH OF BAR: 74 FEET 74 FEET/2 FEET = 37 OCCUPANTS 2 FEET/PERSON - BOOTH SEATING TOTAL 2' LENGTHS: 38 38 (2') LENGTHS = 38 OCCUPANTS 200 NET SF/PERSON - KITCHEN TOTAL NET SF OF AREA: 1,400 NSF 1,400 NSF/200 NSF = 7 OCCUPANTS 300 GROSS SF/PERSON - STORAGE/MECHANICAL TOTAL NET SF OF AREA: 164 GSF 164 GSF/300 GSF = 1 OCCUPANTS 100 GROSS SF/PERSON - OFFICE TOTAL GROSS SF OF AREA: 52 52 GSF/100 GSF = 1 OCCUPANTS EMPLOYEES = MAXIMUM 30 PER SHIFT TOTAL OCCUMPANT LOAD: 296 OCCUPANTS EXIT DOORS MUST SWING OUTWARDS IF 50 OR MORE OCCUPANTS. TWO EXITS REQUIRED. PLUMBING FACILITIES: OCCUPANCY A-2 (RESTAURANT) PER INDIANA AMENDMENT EXCEPTION 2 TO SEC. 2902.1.1 ACTUAL OCCUPANTS FOR SPACE IS PERMITTED IN LIEU OF CALCULATED OCCUPANT LOAD WHEN DETERMINING PLUMBING FIXTURE CALCULATION SEATING CAPACITY= 190 OCCUPANTS EMPLOYEES = MAXIMUM 30 PER SHIFT TOTAL ACTUAL OCCUPANTS = 220 OCCUPANTS 1 WC REQ PER 75 OCCUPANTS IN A-2 220/75 = 3 WC REQUIRED 3 WC PROVIDED SMOKE DETECTORS: REFER TO M/E/P DRAWINGS ENERGY REQUIREMENTS: CLIMATE ZONE 5 ROOFS- R-20 (CONTINUOUS) (INSULATION ABOVE DECK) WALLS- R-13 + R7.5 (CONTINUOUS) (ABOVE GRADE, STEEL-FRAMED) WALLS- R-7.5 (CONTINUOUS) (WALL BELOW GRADE) FLOORS- NO REQUIREMENT (SLAB ON GRADE - UNHEATED) BUILDING CODE INFORMATION 200 S MERIDIAN ST, SUITE 301 INDIANAPOLIS, INDIANA 46225PH: 317.501.6021 INFO@ONE10STUDIO.COMONE10STUDIO.COMdrawn: checked: certification: sheet number: date: description:Copyright: ONE 10 STUDIO Architects, 2021PERMIT SET sheet title: consultants: DWT CAK 06.16.2021 A000019.016The Garden Table - CarmelCarmel, IN PERMIT SET Cover Sheet The Garden Table - Carmel CARMEL, IN SHEET INDEX #NAME GENERAL INFO A000 Cover Sheet ARCHITECTURAL A001 Exterior Patio and Seating Plan A002 Life Safety/Wall Types A010 Demolition Floor Plan A100 Overall Floor Plan A101 Dimension Plan A110 Ceiling Plan A120 Finish Plan A200 Exterior Elevations A300 Building Sections A400 Enlarged Plans/ Interior Elevations/Sections A402 Enlarged Plans/Interior Elevations/Sections A500 Details A501 Details A502 Details A600 Schedules/ Diagrams/ Openings A900 3D Drawings ELECTRICAL E100 Floor Plan Lighting Work E200 Floor Plan Lighting Work E300 Electrical Details E301 Electrical Details E400 Electrical Specifications FA100 Floor Plan Electrical Work MECHANICAL M100 Floor Plan Mechanical Work M200 Mechanical Details M201 Mechanical Details M300 Mechanical Details PLUMBING P100 Floor Plan Water Piping Work P200 Floor Plan Sanitary and Vent Piping P300 Floor Plan Gas Piping Work P400 Plumbing Details P401 Plumbing Details P402 Sanitary and Vent Riser Diagram P500 Plumbing Specifications ROOM IDENTIFICATION SECTION CUT INDICATION DETAIL IDENTIFICATION ELEVATION SYMBOL REVISION SYMBOL SPECIFIC NOTES WINDOWS/GLAZING IDENTIFICATION DOOR IDENTIFICATION FURNITURE AND EQUIPMENT IDENTIFICATION TOILET ACCESSORIES GENERAL NOTES WALL TYPE ELEVATION ANNOTATION NORTH ARROW 1 1 NOTE 100 x FIRST LEVEL ELEV. 100'-0" 1 A1 1 A1 100 ROOM NAME 1 1 X 1 A1 VERIFICATION NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS/ CLEARANCES AND ALL EXISTING FIELD CONDITIONS BEFORE STARTING CONSTRUCTION. COMMENCEMENT OF WORK CONTITUTES ACCEPTANCE OF CONDITIONS. SHOULD DIFFERENT CONDITIONS BE FOUND, CONTACT THE ARCHITECT BEFORE STARTING ANY WORK. 08/03/21