HomeMy WebLinkAboutA000_Cover SheetMERIDIAN STKEYSTONE AVEPEND
L
E
T
ON PIK E
38TH ST
I-70
WASHINGTON STI-465I -465 I-65SMICHIGAN RDI-6
5
N
I -70
ROCKV
I
L
LE RD
INDIANAPOLIS
SITE
LOCATION
LOCATION MAP
SCALE: N.T.S.
CENTER LINE
ABOVE FINISH FLOOR
AIR CONDITIONER
ALUMINUM
BELOW FINISH FLOOR
BUILDING
CABINET
CARPET
CEILING
CERAMIC TILE
CLOSET
COLUMN
CONCRETE MASONRY
UNIT
CONTINUOUS
DEMOLITION
DETAIL
DIAMETER
DOWN
DOWNSPOUT
DRAWING
ELEVATOR
EQUIPMENT
EXISTING
EXTERIOR
FEET
FINISH
FIRE EXTINGUISHER
FLOOR DRAIN
FOOTING
GLASS, GLAZING
GYPSUM
HEIGHT
HOLLOW CORE
HOLLOW METAL
INSULATION
INTERIOR
JUNCTION BOX
LAMINATE
LAVATORY
MAXIMUM
METAL
MECHANICAL
MINIMUM
MIRROR
CL
AFF
A/C
ALUM
BFF
BLDG
CAB
CPT
CLG
CT
CLO
COL
CMU
CONT
DEMO
DTL
DIA
DN
DS
DWG
ELEV
EQUIP
EXIST
EXT
FT
FIN
FE
FD
FTG
GL
GYP
HT
HC
HM
INSUL
INT
JB
LAM
LAV
MAX
MTL
MECH
MIN
MIR
NOT TO SCALE
NUMBER
ON CENTER
OWNER FURNISHED/
OWNER INSTALLED
OWNER FURNISHED/
CONTRACTOR INSTALLED
CONTRACTOR FURNISHED/
CONTRACTOR INSTALLED
PAINT
PLUMBING
PROJECT
REINFORCEMENT
REQUIRED
REVISION
ROUGH OPENING
SIMILAR
SOAP DISPENSER
SIMULATED DIVIDED LITE
SQUARE FEET
STANDARD
STAINLESS STEEL
STEEL
STORAGE
TYPICAL
URINAL
WATER CLOSET
WITHOUT
WOOD
NTS
NO.
O.C.
OFOI
OFCI
CFCI
PT
PLBG
PROJ
REINF
REQ
REV
RO
SIM
SD
SDL
SF
STD
SS
STL
STOR
TYP
UR
WC
W/O
WD
ELEVATION
CERAMIC TILE
MASONRY
CONCRETE
WOOD
BRICK
GLAZING
SECTION
EARTH
CONT. WOOD/
BLOCKING
WOOD BLOCKING
SHEATHING
INSULATION BOARD
INSULATION
RIGID INSULATION
BATT INSULATION
BRICK
GYPSUM BD./
STUCCO
CONCRETE
STEEL
ALUMINUM
THIS PROJECT WAS DESIGNED USING THE FOLLOWING CODES:
INDIANA BUILDING CODE, 2014 EDITION
(IBC, 2012 EDITION, 1ST PRINTING)
INDIANA FIRE CODE, 2014 EDITION
(IFC, 2012 EDITION, 1ST PRINTING)
INDIANA PLUMBING CODE, 2012 EDITION
(IPC, 2006 EDITION)
INDIANA ELECTRICAL CODE, 2009 EDITION
(NFPA 70-2008)
INDIANA MECHANICAL CODE, 2014 EDITION
(IMC, 2012 EDITION, 1ST PRINTING)
INDIANA ENERGY CONSERVATION CODE, 2010
(ASHRAE 90.1, 2007 EDITION, AS AMENDED)
USE AND OCCUPANCY:
GROUP A2 (RESTAURANT)
OCCUPANT LOAD FACTOR: 100SF/ PERSON
GENERAL BUILDING HEIGHTS AND AREAS:
CONSTRUCTION TYPE: III-B
ALLOWABLE (A2 -IA): ULSF, UL STORIES- UL FEET
TENANT AREA:
CONDITIONED 3,945 SF
INDOOR/OUTDOOR PATIO 2,161 SF
OUTDOOR PATIO 1,692 SF
OCCUPANT LOAD: 296 PEOPLE (2 EXITS REQUIRED).
5 NET SF/PERSON - STANDING
TOTAL NET SF OF AREA: 236 NSF
236 NSF/5 NSF = 48 OCCUPANTS
15 NET SF/PERSON - TABLES/CHAIRS
TOTAL NET SF OF AREA: 2,001 NSF
2,001 NSF/15 NSF = 134 OCCUPANTS
2 FEET/PERSON - BAR SEAT LENGTH
TOTAL LENGTH OF BAR: 74 FEET
74 FEET/2 FEET = 37 OCCUPANTS
2 FEET/PERSON - BOOTH SEATING
TOTAL 2' LENGTHS: 38
38 (2') LENGTHS = 38 OCCUPANTS
200 NET SF/PERSON - KITCHEN
TOTAL NET SF OF AREA: 1,400 NSF
1,400 NSF/200 NSF = 7 OCCUPANTS
300 GROSS SF/PERSON - STORAGE/MECHANICAL
TOTAL NET SF OF AREA: 164 GSF
164 GSF/300 GSF = 1 OCCUPANTS
100 GROSS SF/PERSON - OFFICE
TOTAL GROSS SF OF AREA: 52
52 GSF/100 GSF = 1 OCCUPANTS
EMPLOYEES = MAXIMUM 30 PER SHIFT
TOTAL OCCUMPANT LOAD: 296 OCCUPANTS
EXIT DOORS MUST SWING OUTWARDS IF 50 OR MORE OCCUPANTS.
TWO EXITS REQUIRED.
PLUMBING FACILITIES:
OCCUPANCY A-2 (RESTAURANT)
PER INDIANA AMENDMENT EXCEPTION 2 TO SEC. 2902.1.1 ACTUAL
OCCUPANTS FOR SPACE IS PERMITTED IN LIEU OF CALCULATED
OCCUPANT LOAD WHEN DETERMINING PLUMBING FIXTURE CALCULATION
SEATING CAPACITY= 190 OCCUPANTS
EMPLOYEES = MAXIMUM 30 PER SHIFT
TOTAL ACTUAL OCCUPANTS = 220 OCCUPANTS
1 WC REQ PER 75 OCCUPANTS IN A-2
220/75 = 3 WC REQUIRED
3 WC PROVIDED
SMOKE DETECTORS:
REFER TO M/E/P DRAWINGS
ENERGY REQUIREMENTS:
CLIMATE ZONE 5
ROOFS- R-20 (CONTINUOUS)
(INSULATION ABOVE DECK)
WALLS- R-13 + R7.5 (CONTINUOUS)
(ABOVE GRADE, STEEL-FRAMED)
WALLS- R-7.5 (CONTINUOUS)
(WALL BELOW GRADE)
FLOORS- NO REQUIREMENT
(SLAB ON GRADE - UNHEATED)
BUILDING CODE INFORMATION
200 S MERIDIAN ST, SUITE 301 INDIANAPOLIS, INDIANA 46225PH: 317.501.6021 INFO@ONE10STUDIO.COMONE10STUDIO.COMdrawn:
checked:
certification:
sheet number:
date: description:Copyright: ONE 10 STUDIO Architects, 2021PERMIT SET
sheet title:
consultants:
DWT
CAK
06.16.2021
A000019.016The Garden Table - CarmelCarmel, IN
PERMIT SET
Cover Sheet
The Garden Table - Carmel
CARMEL, IN
SHEET INDEX
#NAME
GENERAL INFO
A000 Cover Sheet
ARCHITECTURAL
A001 Exterior Patio and Seating Plan
A002 Life Safety/Wall Types
A010 Demolition Floor Plan
A100 Overall Floor Plan
A101 Dimension Plan
A110 Ceiling Plan
A120 Finish Plan
A200 Exterior Elevations
A300 Building Sections
A400 Enlarged Plans/ Interior Elevations/Sections
A402 Enlarged Plans/Interior Elevations/Sections
A500 Details
A501 Details
A502 Details
A600 Schedules/ Diagrams/ Openings
A900 3D Drawings
ELECTRICAL
E100 Floor Plan Lighting Work
E200 Floor Plan Lighting Work
E300 Electrical Details
E301 Electrical Details
E400 Electrical Specifications
FA100 Floor Plan Electrical Work
MECHANICAL
M100 Floor Plan Mechanical Work
M200 Mechanical Details
M201 Mechanical Details
M300 Mechanical Details
PLUMBING
P100 Floor Plan Water Piping Work
P200 Floor Plan Sanitary and Vent Piping
P300 Floor Plan Gas Piping Work
P400 Plumbing Details
P401 Plumbing Details
P402 Sanitary and Vent Riser Diagram
P500 Plumbing Specifications
ROOM IDENTIFICATION
SECTION CUT INDICATION
DETAIL IDENTIFICATION
ELEVATION SYMBOL
REVISION SYMBOL
SPECIFIC NOTES
WINDOWS/GLAZING
IDENTIFICATION
DOOR IDENTIFICATION
FURNITURE AND EQUIPMENT
IDENTIFICATION
TOILET ACCESSORIES
GENERAL NOTES
WALL TYPE
ELEVATION ANNOTATION
NORTH ARROW
1
1
NOTE
100
x
FIRST LEVEL
ELEV. 100'-0"
1
A1
1
A1
100
ROOM NAME
1
1
X
1
A1
VERIFICATION NOTE:
CONTRACTOR SHALL VERIFY ALL DIMENSIONS/ CLEARANCES AND ALL
EXISTING FIELD CONDITIONS BEFORE STARTING CONSTRUCTION.
COMMENCEMENT OF WORK CONTITUTES ACCEPTANCE OF
CONDITIONS. SHOULD DIFFERENT CONDITIONS BE FOUND, CONTACT
THE ARCHITECT BEFORE STARTING ANY WORK.
08/03/21