Loading...
HomeMy WebLinkAboutPillar Group 06100010Item 1 of UvrKL-11urt: U COPY # : 1 Sec: Twp: Rng: Sub: Blk: Lot: PARCEL ID 1613110418001011 DATE ISSUED.......: 10/05/2006 RECEIPT #........-: 23348 REFERENCE ID # ...: 06100010 SITE ADDRESS 401 PENNSYLVANIA PKWY SUBDIVISION ....... CITY INDIANAPOLIS IMPACT AREA 31 OWNER LAUTH ADDRESS 401 PENNSYLVANIA PKWY CITY/STATE/ZIP ...: INDIANAPOLIS, IN 46280 RECEIVED FROM ....: A SIGN BY DESIGN CONTRACTOR LIC # COMPANY .......... ADDRESS ...... CITY/STATE/ZIP TELEPHONE ........ FEE ID UNIT QUANTITY AMOUNT PD-TO-DT THIS REC NEW BAL SIGNINSTAL SQUARE FEET ^- 80.00 168.00 0.00 168.00 0.00 SIGNPERM FLAT RATE 1.00 80.00 0.00 80.00 0.00 TOTAL PERMIT 248.00 0.00 248.00 0.00 METHOD OF PAYMENT AMOUNT NUMBER YY CHECK 248.00 19884 TOTAL RECEIPT 248.00 SIGN COPY PILLAR GROUP SIGN ADDRESS DATE RECEIVED: CITY OF CARMELICLAY TOWNSHIA HAMILTON CO Y. INDIANA SIGN PERMIT APPLICATION PERMIT NUMBER: Gii /0 &o /o NAME OF BUSINESS PILLAR GR❑ P PHONE: PROPERTY OWNER CITY: QARMFL STATE: --IN-ZIP:46980 PHONE: ADDRESS: 401 PENNSYLVANIA CITY: CARMEL STATE: IN. ZIP:46280 ZONING DISTRICT: OVERLAY ZONE: 31 421 431 OLD TOWN: YES _ NO Dr/Av-0 REQUIRED APPROVALS: Plan Commission Docket # 45080011 A911W A Docket #050 51 37 ROCS Only IS AN IMPROVEMENT LOCATION PERMIT REQUIRED FOR THIS BUILDING/TENANT SPACE? IF YES, STATE PERMIT NUMBER ISSUED SIGN TYPE -circle one: WALL GROUND ROOF PROJECTING SUSPENDED PORCH WINDOW OTHER NO. OF SIDES I SIGN STATUS -circle appropriate response( _ NEW EXISTING P RMANENT TEMPORARY nvFu AT T 0,MM NFTGHT FRnM C:R0I IND: 53 FT. OVERALL SIGN DIMENSIONS: 2.6 FT. x 30.8 T. TOTAL SIGN AREA: Requested 80 SQ.FT. Permissible 100 SQ.FT. COLORS: day / night black BUILDING OR TENANT SPACE FRONTAGE DIMENSION: 282 FT. BUILDING TYPE: Mulil . ory / multi tenant SETBACK OF SIGN FROM NEAREST RIGHT-OF-WAY:. + FT. LOGO DIMENSIONS: = LOGO IS 10.75 PERCENT OF SIGN AREA ARE THERE ANY EXISTING SIGNS ON THIS SITE? IF YES, EXPLAIN SHOPPING CENTER OR COMPLEX NAME' MFRIDIA O PORATE PL X CERTIFY THAT A PICTURE OF THIS SIGN WILL BE SUBMITTED TO THE DEPARTMENT OF COMMUNITY SERVICES WITHIN ONE (1) WEEK AFTER ERECTION OF THE SIGN. -OR- I WOULD PREFER A $93.50 INSPECTION FEE BE ADDED TO THE COST OF THIS PERMIT TO COVER THE COST OF THE STAFF OF THE DEPARTMENT OF COMMUNITY SERVICES TAKING THIS PICTURE. TWO COPIES OF THE FOLLOWING DOCUMENTATION ARE REQUIRED FOR THE REVIEW OF THIS SIGN PERMIT: * COMPLETED APPLICATION * SITE PLAN (depicting all dimensions, setbacks and proposed sign location) * SIGN• ELEVATIONS (depicting all dimensions, copy and color) * BUILDING OR TENANT SPACE ELEVATION (depicting frontage dimensions and proposed sign location) * LANDSCAPE PLAN: Required for ground signs (depicting the planting, mature heights and caliper) * See Samples Attached SIGN PERMIT FEES: -PERMIT APPLICATION ........................... $77.25 -SIGN ERECTION ....................................... $30.90 PER SIGN FACE PLUS $1.65 PER SQUARE FOOT -REPLACEMENT OF SIGN FACE IN AN EXISTING CABINET--$30.90 PLUS $1.65 PER SQUARE FOOT (Continued On Page 2) 1G-13-11-91-Ig-001.P/1 09/18/2006 14:35 FAX 3172752778 LAUTH PROPERTY Q003 Page 2 of 2 Carmel/Clay Sign Pcrmit Application THE UNDERSIGNED CERTIFIES THAT THE FOREGOING SIGNATURES, STATEMENTS AND ANSWERS HEREIN CONTAINED AND THE INFORMATION HEREWTFH SUBMITTED ARE IN ALL RESPECTS TRUE AND CORRECT, AND THIS SIGN WILL BE ERECTED AND MAINTAINED IN ACCORDANCE WITH ALL APPLICABLE LAWS OF THE STATE OF INDIANA, AND THE - ZONING ORDINANCE OF CARMEL/CLAY TOWNSHIP, INDIANA AND ALL ACTS AMENDATORY TI-MRETO, AND SHALL BE ERECTED WITHIN SIX (6) MONTHS OF THE DATE OF ISSUANCE OR THIS PERMIT 1S NULI. AND VOID. FURTHER, THE UNDERSIGNED CERTIFIED BY SIGNING THIS APPLICATION THAT ALL REPRESENTATIVES OF THE DEPARTMENT OF COMMUNITY SERVICES ARE ADVISORY. 00 PROPERTY OWN�GNATURE: Bi15IN1=55 PROPERTY OWNER`S NAME (PLEASS PRINT) BUSFNFSS OWNER'S NAME (PLEASE PRINT) SIGN COMPANY: A Sion by Desian, Inc. CONTACT PERSON: Don ' r _ PHONE:.Zi - fi-7900 ADDRESS: 4= W. 106th St. CITY: Zionsville STATE: IN ZIP:46077 THE FOLLOWING ITEMS ARE CONCERNS BY STAFF OR PRIOR COMMITMENTS THAT MUST BE ADHERED TO AS A CONDITION OF THE ISSUANCE OF THIS PERMIT (PLEASE INITIAL EACH ITEM INDIVIDUALLY): 1) x 3) x 4) x� 5) x SION PERMIT APPLICATION $ woo q SIGN ERECTION - Improvement Permit $ �� 4' 1. / 4't v �0� INSPECTION FEE (Required if photography not provided) $93.50 OR Photo will be provided TOTAL FEE PERMIT ISSUED BY: FEE, RECEIVED BY. RELEASED STAMP: PAID STAMP: s:lsignlannl revised 01 /04/05 Tr T7,;D 0C,T-- PAID, uj w x F C wl III c V J d d ❑ Ld Z �I O10 O 2 in Q� rZ ~ w ..� O c q a) o x z= U>F3 Z F;-I` - z L, N OZ as Q r U % 0 CP �j�j N to r ZUJZU J 2 �M- :E zal S� LO ti c- z < x Q u z K lZ-ll FuJ W d� m0¢ NJp=LL W x p�00 mlZ_7� Ji OwF c¢ G w Z LL W O p m x W p z U - w w J W Z U U J U w cj-O LL LL Q 111 r N M W 111 i m a a m O Cc 0 m ❑ w m ❑ W m fr O w 0 ❑ 0 0.. W m W m 0 H I— O Z L cl Q U Z Z 0 Fn w m Z m ¢ LL r0 r W IL 0 IL w J 0 w 2 H 0 Z cr- L 2 w l7 z uP 0 0 "' LU z❑ J J LLJ ❑ V) J z J — 0 W vi _ Z ~ — LL O 0 I— Ul) w Z Z = L W ❑ O W d Q Z U Q O 2 z� ¢ LL LJ J z< zL z� U w OC J 0 W w J W 00 V1 Q 00 a wV) H °C w O Z Z Z ,n 0 U Z J Ur _l N W z >- V) m LU 0 ❑ Vl m ¢ z Eli OF CITY CARMEL �..�. DEPARTMENT OF COM MUNITY SERVICES aolfll�ii�t�lt Division of Planning & Zoning LETTER of GRANT December 28, 2005 Doug Fischer Meridian Corporate Plaza 401 Pennsylvania Parkway Indianapolis IN 46280 RE: Docket No. 05080011 DPI DLLS Meridian Cor orate Plaza Dear Doug: At the meeting of the Carmel Plan Commission held December 20, 2005, the Commission took the following action regarding the Development Plan and Architectural. Design, Lighting, Landscaping & Signage (DPIADLS) for Meridian Corporate Plaza located at 401 Pennsylvania Parkway, Indianapolis. APPROVED: Docket No. 05080011 DP/ADLS, Meridian Corporate Plaza. The Commission approved the request by a vote of 10 in favor none opposed, subject to approval by the Urban Forester of the landscape plan and trees on the mound, review by the Department of the photometric plan, and comnutments as stated by the petitioner, thereby granting the petition. NOTE: This Letter of Grant supersedes the previous Letter of Grant dated October 31, 2005. In order to assist the Department's review, please attach a copy of this letter when making application for permits regarding the improvements contained within this approval. Do not hesitate to contact me if I can be of further assistance. Sinc ely, Matt L. Griffin Planning Administrator Department of Community Services 317-571-2417 cc: Sarah Lillard cc: Steve Granner cc: file 05080011 DP/AD1S, MeridianCorporatePlaza T'd Letter MERIDIAN CORPORATE PLAZA � WALL SIGN CRITERIA - wlj� PURPOSE: The purpose of these sign requirements is to assure sign continuity and uniformity throughout the office complex. It is essential thdt the signage compliment the architectural design of the area and that the esthdtics of the complex be maintained at all times. All signs must be approved, in writing, by Landlord or its representative. GENERAL: All signs must consist of individually illuminated channel letters. All letter components are to be constructed and installed as described within the following criteria. Tenant shall be responsible for the fulfillinent of all requirements and specifications, including those of the applicable local governing agency and/or codes, and obtaining all necessary sign permits. Tenant shall be responsible for the installation and maintenance of their sign. Should Tenant's sign require maintenance or repair, Landlord shall give Tenant thirty (30) days written notice to effect said maintenance or repair. Should Tenant fail to do same; Landlord shall have the right to undertake repairs and Tenant shall reimburse Landlord. Wording of the signs shall not include the trade name of products sold or the price of items sold except as a part of the Occupant's trade name or insignia. Use of generic terms will be reviewed on an individual basis. DESIGN: Tenant signs shall not be restricted to a certain letter style or font. Each letter or logo construction, lighting, and installation must be consistent with the letter components of the National Electrical Code. Layouts must be submitted to the Landlord for written approval prior to sign construction. Drawings must include copy, size, colors, placement and a cross section detailing the installation. Upon approval, a permit application must be filed, by tenant, with the Carmel/Clay Township Department of Community Development. A copy of the approved permit must be returned to the Landlord prior to sign installation. No sign of any sort shall be permitted on top of the building roof. All exterior signs exposed to the weather shall be mounted flush on the building to permit proper dirt and water drainage. Each sign will also have weep holes at the bottom to allow for proper drainage. CONSTRUCTION: Letter and logo components are to be constructed from 5" depth black aluminum with a baked enamel finish. The faces are,to be fabricated from 3/16" CAS Acrylic (day/night plex). The faces are to be attached with a 1" depth, extruded plastic trim cap in black that will be chemically adhered to the edges of the faces and mechanically fastened to the returns, with stainless steel crew heads painted to match the trim cap. LIGHTING: Illumination is to be EGL / CL 8300 Designer White Neon tubing within the channels. NUMBER: Meridian Corporate Plaza Two: There may be a combined total of three (3) wall signs for the building, with no more than one sign on each of the northwest, northeast, southeast and southwest fagades. The north and south fagades may have a maximum of two (2) signs. Meridian Corporate Plaza Three: There may be a combined total of three (3) wall signs for the building, with no more than one sign on each of the northwest, northeast, southeast and southwest fayades. The north and south fagades may have a maximum of two (2) signs. SIZE: No individual wall sign shall exceed 100 square feet. No letter can be taller than 54" in height. Logos are not to exceed 25% of the allowable sign area. All signs, except for logos, are to be on one line. (No stacked formats, except for logos) PLACEMENT: Signs may be placed at any of the sign locations shown in Exhibits A and B, subject to the limitations on number of signs. These proposed sign locations are approximate only. Final placement will be determined by the Landlord. Signs must be centered horizontally with adjacent signage on the building. A photo rendering of placement must accompany the spec drawing for final approval. The Landlord reserves the right to adjust placement to ensure architectural compatibility with the fagade. INSTALLATION: All components are to be installed on the sign band and anchored to the background surface. Neon connections to the secondary wiring are to be made in UL approved conduit. All secondary wiring is to be installed on the backside of the wall enclosed in grounded metallic flexible conduit. 120 volt transformers are to be installed in vented metal boxes on the backside of the wall. Primary, wiring to the sign, including a time clock, is the responsibility of the tenant. The Tenant is to maintain a consistent on/off schedule as specified by the'Landlord. All signs are to be fabricated and installed based on U.L. specifications. 1