HomeMy WebLinkAboutE100.0HB
GFCI WP
GFCI WP
GFCI
GFCI
GFCI GFCI GFCI
WP
WP
WP
EP
R R
RR
WP
WP
RR
WP
WP
GFCI
WP
WP
WP
WP
NEW
STORAGE
ROOM
INSTALL (2) HOMEOWNER-PROVIDED CEILING FANS ON NEW
SINGLE-POLE SWITCH IN WEATHERPROOF ENCLOSURE
EXISTING METER BASE
FURNISH & INSTALL (1) 15A 120V GFCI RECEPTACLE
WEATHERPROOF ENCLOSURE, 16" A.F.F
FURNISH NEW 100A
SUBPANEL FED FROM HOUSE
FURNISH & INSTALL (3) 15A
120V GFCI RECEPTACLES IN
STORAGE ROOM, 48" A.F.F
FURNISH & INSTALL (2)
KEYLESS LIGHT FIXTURES
WITH LED BULBS ON NEW
SINGLE-POLE SWITCH
FURNISH & INSTALL (2) 15A
120V GFCI RECEPTACLES,
76" A.F.F.
FURNISH & INSTALL (1) 15A
120V GFCI RECEPTACLE
WEATHERPROOF
ENCLOSURE, 16" A.F.F
FURNISH & INSTALL (1) 15A
120V GFCI RECEPTACLES
FOR UNDER-COUNTER
REFRIGERATOR
FURNISH & INSTALL (2) 15A 120V GFCI
RECEPTACLES IN BACKSPLASH
FURNISH & INSTALL (1) 15A 120V
GFCI RECEPTACLE FOR GRILL
FURNISH & INSTALL (1) 15A 120V GFCI
RECEPTACLE ON SIDE OF GRILL BASE CABINET
NEW CABANA
NEW
CHANGING
ROOM
FURNISH & INSTALL (1)
EXHAUST FAN / LIGHT
FIXTURE ON NEW SINGLE-
POLE SWITCH
FURNISH & INSTALL (1) 15A
120V GFCI RECEPTACLE IN
CHANGING ROOM, 48" A.F.F
FURNISH & INSTALL (1) 15A 120V
GFCI RECEPTACLE IN
WEATHERPROOF ENCLOSURE ON
16"H TREATED WOOD PEDESTAL
FURNISH & INSTALL (1) 15A 120V
GFCI RECEPTACLE IN
WEATHERPROOF ENCLOSURE ON
16"H TREATED WOOD PEDESTAL
FURNISH & INSTALL (1) 15A 120V GFCI
RECEPTACLE FOR EXHAUST HOOD
INSTALL (2) HOMEOWNER-PROVIDED 240V 6000W INFRARED HEATERS
WITH CONTROLLER RELAY PANEL & THERMOSTATIC CONTROLS
FURNISH & INSTALL (4) 15A 120V GFCI
RECEPTACLES AT CEILING PERIMETER FOR
HOMEOWNER-PROVIDED TAPE LIGHTING
N PERMIT
#0
ISSUE DATE:
2021-07-26
REV:
www.caseindy.com
99 E. Carmel Drive, Suite 100
Carmel, Indiana 46032
317.846.2600 317.846.2601(f)
These drawings have been prepared
by Case Design & Remodeling solely
for its use and should not be
reproduced or relied upon by any
other parties. Dimensions shown or
scaled are subject to change per
actual job condition and must be
verified. Materials are to be supplied
as specified as equal or standardwhen not uniquely specified. Installed
materials may vary in appearance
from drawings. Reference
manufacturer's product data for actual
appearance and specifications.CAMPBELL PROJECTNEW DECK & POOL HOUSEBOB & SUSAN CAMPBELL14378 AVIAN WAYCARMEL, INDIANA 46033Approved By:
Date:
E101
Craig Dice
Architectural Designer
cdice@caseindy.com
Dave Null
Lead Designer
dnull@caseindy.com
252160171
JOB NUMBER:
PROPOSED ELECTRICAL PLANA
E101
A
E101 SCALE: 1/8" = 1'-0"
08/06/21