Loading...
HomeMy WebLinkAboutA002 - Code Analysis and Accessbility DetailsDWDW REF REF D D WW MicrowaveOvenLEGEND EXIT PATH OCCUPANCY LOAD EGRESS WIDTH.2" PER PERSONOCCUPANCY LOAD= 28 OCCUPANTS 28 OCCUP x .2"= 4.6" EGRESS MINIMUM REQUIRED= 32" PROVIDED= 128" RESIDENTIAL 200 GSF SF= 4561 OLF= 4561 / 200 = 22.805 = 23 HOME OFFICELAUNDRY RM FLEX SPACE PWDR RM LIBRARYSLEEPING ROOM SLEEPING ROOM SLEEPING ROOM SLEEPING ROOM SLEEPING ROOM SLEEPING ROOM SLEEPING ROOM SLEEPING ROOM MECH PANTRY O. PWDR RM 105106 107 108 109 101102103104 110 CLOSETACTIVITY STORAGE SLEEPING ROOM SLEEPING ROOM CORRIDOR ENTRY ACTIVITY AREA LIVING ROOM DINING ROOM KITCHEN BATHBATH BATHBATH BATH BATH BATH BATH BATH BATH EXIT 1 EXIT 2 EXIT 3 SCALE: PROJECT NUMBER:PLOT DATE:757 FREDERICK  ROAD SUITE 202 CATONSVILLE, MD  21228 (410) 461‐7763 JSRASSOCIATES.NET JANE@JSRASSOCIATES.NET Professional Certification: JANE ROHDE, ARCHITECT REGISTRATION #: AR11000159 STATUS: REVISION LOG REV # DATE DESCRIPTION DRAWN BY: SHEET NO. SHEET NAME BUILDER: As indicated 12/21/2020 8:55:25 PMCODE ANALYSIS AND TYPICAL ACCESSIBILITY DETAILS 29012 Author A002Willow Haven Senior HomesJames MilesPERMIT2080 W 106th Street, Carmel, IN 46032DWELLING, SINGLE-FAMILY. A RESIDENTIAL BUILDING CONTAINING ONLY ONE (1) DWELLING UNIT AND NOT OCCUPIED BY MORE THAN ONE (1) FAMILY. PURSUANT TO IC 12-28-4-7, A GROUP HOME FOR THE MENTALLY ILL SHALL BE TREATED AS IF IT WERE A SINGLE-FAMILY DWELLING, UNLESS THE GROUP HOME WILL BE LOCATED WITHIN THREE THOUSAND (3,000) FEET OF ANOTHER GROUP HOME FOR THE MENTALLY ILL, AS MEASURED BETWEEN LOT LINES. PURSUANT TO IC 12-28-4-8, A GROUP HOME FOR NOT MORE THAN TEN (10) DEVELOPMENTALLY DISABLED INDIVIDUALS WHICH IS ESTABLISHED UNDER A PROGRAM AUTHORIZED BY IC 12-11-1.1-1(E)(1) OR IC 12-11-1.1-1(E)(2) SHALL BE TREATED AS IF IT WERE A SINGLE-FAMILY DWELLING. IBC/IRC/VCC/VRC OCCUPANCY CLASSIFICATIONS TYPE OF CONSTRUCTION NUMBER OF STORIES ABOVE GRADE HEIGHT OF BUILDING GARAGE (Y/N) TOTAL AREA OF BUILDING SPRINKLERED (Y/N) FIRE ALARM (Y/N) FIRE RATING FINISHES LEVEL ABOVE GRADE CODE REFERENCES 2020 INDIANA RESIDENTIAL CODE (IRC) SCOPE OF WORK PREPARE CONSTRUCTION DOCUMENTS FOR NEW SINGLE FAMILY GROUP HOME TO HOUSE 10 LIVE IN RESIDENTS. SPACE TO INCLUDE KITCHEN, LIVING AREA, DINING AREA, LIBRARY, HOME OFFICE, FLEX SPACE, LAUNDRY ROOM, MECHANICAL ROOM, STORAGE AREA AND 10 SLEEPING ROOMS WITH ACCESS TO PRIVATE BATHROOMS. SITE/BUILDING DATA • USE AND OCCUPANCY: SINGLE FAMILY DWELLING (GROUP HOME) PROPOSED BUILDING SINGLE FAMILY HOME/GROUP HOME 10 INDIVIDUALS) VB Y(13R) Y 1 STORY 26'-9" 5838 SF NO BASED ON CHART R302.1(2) CLASS C 1 ROOMS Name Area ACTIVITY AREA 441 SF BATH 50 SF BATH 50 SF BATH 50 SF BATH 50 SF BATH 50 SF BATH 50 SF BATH 50 SF BATH 50 SF BATH 50 SF BATH 50 SF CLOSET 46 SF CORRIDOR 554 SF DINING ROOM 211 SF ENTRY 62 SF FLEX SPACE 75 SF HOME OFFICE 126 SF KITCHEN 320 SF LAUNDRY RM 115 SF LIBRARY 90 SF LIVING ROOM 317 SF MECH 152 SF O. PWDR RM 35 SF PANTRY 30 SF PWDR RM 57 SF SLEEPING ROOM 143 SF SLEEPING ROOM 143 SF SLEEPING ROOM 143 SF SLEEPING ROOM 143 SF SLEEPING ROOM 143 SF SLEEPING ROOM 143 SF SLEEPING ROOM 143 SF SLEEPING ROOM 143 SF SLEEPING ROOM 143 SF SLEEPING ROOM 143 SF 0 HOURS REQ. WALL AND CEILING FINISHES FLAME SPREAD INDEX: NOT GREATER THAN 200 WALL AND CEILING FINISHES SMOKE SPREAD INDEX: NOT GREATER THAN 450 R320.1 ACCESSIBILITY WHERE THERE ARE FOUR OR MORE DWELLING UNITS OR SLEEPING UNITS IN A SINGLE STRUCTURE, THE PROVISIONS OF CHAPTER 11 OF THE INTERNATIONAL BUILDING CODE FOR GROUP R-3 SHALL APPLY. CONSTRUCTION SLAB ON GRADE NOTE THAT THIS STRUCTURE DOES NOT REQUIRE FIRE RATING PER THE IRC REQUIREMENTS. 08/09/21