HomeMy WebLinkAboutA002 - Code Analysis and Accessbility DetailsDWDW
REF REF
D D WW MicrowaveOvenLEGEND
EXIT
PATH
OCCUPANCY LOAD
EGRESS WIDTH.2" PER PERSONOCCUPANCY LOAD= 28 OCCUPANTS
28 OCCUP x .2"= 4.6" EGRESS
MINIMUM REQUIRED= 32"
PROVIDED= 128"
RESIDENTIAL 200 GSF
SF= 4561 OLF= 4561 / 200 = 22.805 = 23
HOME OFFICELAUNDRY RM FLEX SPACE
PWDR RM
LIBRARYSLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECH
PANTRY
O. PWDR RM
105106
107
108
109
101102103104
110
CLOSETACTIVITY
STORAGE
SLEEPING
ROOM
SLEEPING
ROOM
CORRIDOR
ENTRY
ACTIVITY AREA
LIVING ROOM DINING ROOM KITCHEN
BATHBATH BATHBATH BATH BATH
BATH
BATH BATH BATH
EXIT 1
EXIT 2
EXIT 3
SCALE:
PROJECT NUMBER:PLOT DATE:757 FREDERICK ROAD
SUITE 202
CATONSVILLE, MD 21228
(410) 461‐7763
JSRASSOCIATES.NET
JANE@JSRASSOCIATES.NET
Professional Certification:
JANE ROHDE, ARCHITECT
REGISTRATION #: AR11000159
STATUS:
REVISION LOG
REV # DATE DESCRIPTION
DRAWN BY:
SHEET NO.
SHEET NAME
BUILDER:
As indicated 12/21/2020 8:55:25 PMCODE ANALYSIS AND TYPICAL
ACCESSIBILITY DETAILS
29012
Author
A002Willow Haven Senior HomesJames MilesPERMIT2080 W 106th Street, Carmel, IN 46032DWELLING, SINGLE-FAMILY. A RESIDENTIAL BUILDING CONTAINING ONLY ONE (1) DWELLING UNIT AND
NOT OCCUPIED BY MORE THAN ONE (1) FAMILY. PURSUANT TO IC 12-28-4-7, A GROUP HOME FOR THE
MENTALLY ILL SHALL BE TREATED AS IF IT WERE A SINGLE-FAMILY DWELLING, UNLESS THE GROUP
HOME WILL BE LOCATED WITHIN THREE THOUSAND (3,000) FEET OF ANOTHER GROUP HOME FOR THE
MENTALLY ILL, AS MEASURED BETWEEN LOT LINES. PURSUANT TO IC 12-28-4-8, A GROUP HOME FOR
NOT MORE THAN TEN (10) DEVELOPMENTALLY DISABLED INDIVIDUALS WHICH IS ESTABLISHED UNDER
A PROGRAM AUTHORIZED BY IC 12-11-1.1-1(E)(1) OR IC 12-11-1.1-1(E)(2) SHALL BE TREATED AS IF IT
WERE A SINGLE-FAMILY DWELLING.
IBC/IRC/VCC/VRC OCCUPANCY
CLASSIFICATIONS
TYPE OF CONSTRUCTION
NUMBER OF STORIES ABOVE GRADE
HEIGHT OF BUILDING
GARAGE (Y/N)
TOTAL AREA OF BUILDING
SPRINKLERED (Y/N)
FIRE ALARM (Y/N)
FIRE RATING
FINISHES
LEVEL ABOVE GRADE
CODE REFERENCES
2020 INDIANA RESIDENTIAL CODE (IRC)
SCOPE OF WORK
PREPARE CONSTRUCTION DOCUMENTS FOR NEW SINGLE FAMILY GROUP HOME TO
HOUSE 10 LIVE IN RESIDENTS. SPACE TO INCLUDE KITCHEN, LIVING AREA, DINING AREA,
LIBRARY, HOME OFFICE, FLEX SPACE, LAUNDRY ROOM, MECHANICAL ROOM, STORAGE
AREA AND 10 SLEEPING ROOMS WITH ACCESS TO PRIVATE BATHROOMS.
SITE/BUILDING DATA
USE AND OCCUPANCY: SINGLE FAMILY DWELLING (GROUP HOME)
PROPOSED BUILDING
SINGLE FAMILY HOME/GROUP HOME
10 INDIVIDUALS)
VB
Y(13R)
Y
1 STORY
26'-9"
5838 SF
NO
BASED ON CHART R302.1(2)
CLASS C
1
ROOMS
Name Area
ACTIVITY AREA 441 SF
BATH 50 SF
BATH 50 SF
BATH 50 SF
BATH 50 SF
BATH 50 SF
BATH 50 SF
BATH 50 SF
BATH 50 SF
BATH 50 SF
BATH 50 SF
CLOSET 46 SF
CORRIDOR 554 SF
DINING ROOM 211 SF
ENTRY 62 SF
FLEX SPACE 75 SF
HOME OFFICE 126 SF
KITCHEN 320 SF
LAUNDRY RM 115 SF
LIBRARY 90 SF
LIVING ROOM 317 SF
MECH 152 SF
O. PWDR RM 35 SF
PANTRY 30 SF
PWDR RM 57 SF
SLEEPING ROOM 143 SF
SLEEPING ROOM 143 SF
SLEEPING ROOM 143 SF
SLEEPING ROOM 143 SF
SLEEPING ROOM 143 SF
SLEEPING ROOM 143 SF
SLEEPING ROOM 143 SF
SLEEPING ROOM 143 SF
SLEEPING ROOM 143 SF
SLEEPING ROOM 143 SF
0 HOURS REQ.
WALL AND CEILING FINISHES FLAME
SPREAD INDEX: NOT GREATER
THAN 200
WALL AND CEILING FINISHES
SMOKE SPREAD INDEX: NOT
GREATER THAN 450
R320.1 ACCESSIBILITY
WHERE THERE ARE FOUR OR MORE DWELLING UNITS OR SLEEPING UNITS IN A SINGLE STRUCTURE,
THE PROVISIONS OF CHAPTER 11 OF THE INTERNATIONAL BUILDING CODE FOR GROUP R-3 SHALL
APPLY.
CONSTRUCTION SLAB ON GRADE
NOTE THAT THIS STRUCTURE DOES NOT REQUIRE
FIRE RATING PER THE IRC REQUIREMENTS.
08/09/21