HomeMy WebLinkAboutWillowHaven_ElectricalSchematicDoc_122120201. THE ELECTRICAL DRAWING INCLUDED HEREIN ARE SCHEMATIC DESIGN DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING ALL FINAL LOAD CALCULATIONS, LIGHTING CALCULATIONS, SIZING OF ALL EQUIPMENT AND WIRING, ETC BASED ON ACTUAL EQUIPMENT INSTALLED. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR CONFIRMING ACTUAL EQUIPMENT SELECTED WILL PHYSICALLY FIT WHILE MAINTAINING CODE AND MANUFACTURER REQUIRED CLEARANCES. 2. ALL ELECTRICAL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST ADOPTED NATIONAL ELECTRICAL CODE AND ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES. 3. ALL FINAL LOCATIONS AND ARRANGEMENTS OF LIGHTING FIXTURES SHALL BE OBTAINED FROM THE ARCHITECTURAL REFLECTED CEILING PLAN. 4. ALL WIRE, CONDUIT, CONNECTORS, OUTLET BOXES, ETC. NECESSARY TO ACHIEVE A COMPLETE ELECTRICAL INSTALLATION WHERE AN ELECTRICAL DEVICE IS REQUIRED BY CODE BUT NOT SHOWN SHALL BE FURNISHED AND INSTALLED AS THOUGH FULLY SHOWN AND SPECIFIED. 5. ALL CONDUIT, JUNCTION BOXES, ETC. ABOVE CEILINGS SHALL BE SUPPORTED FROM THE BUILDING DECK, LIGHTING FIXTURES WHICH ARE INSTALLED IN SUSPENDED CEILING SYSTEMS MUST BE MECHANICALLY FASTENED TO T-BAR SYSTEM AS PER SPECIFICATIONS. 6. NO CUTTING OF BUILDING CONSTRUCTION SHALL BE DONE WHICH MAY IN ANYWAY AFFECT THE BUILDING STRUCTURALLY OR ARCHITECTURALLY WITHOUT FIRST SECURING THE OWNER'S CONSENT AND APPROVAL. 7. NO CONDUITS SHALL BE RUN THROUGH OR SUPPORTED FROM DUCTWORK. 8. ALL AREAS WHICH ARE DAMAGED BECAUSE OF THE ELECTRICAL WORK UNDER THIS CONTRACT SHALL BE REPAIRED AND/OR REFINISHED. THE CONTRACTOR WILL BE RESPONSIBLE FOR ALL CUTTING, PATCHING, PAINTING, AND REMOVING/REPLACING CEILING TILES DAMAGED OR SOILED AS IS NECESSARY. 9. AFTER CONSTRUCTION IS COMPLETED, LABEL ALL CIRCUIT BREAKERS IN ALL ELECTRICAL PANELS INVOLVED. SPARES SHALL BE MARKED AS SPARES. 10. ALL ELECTRICAL WORK, WIRING, CONNECTIONS, AND ASSOCIATED EQUIPMENT WITHIN THE AREA OF WORK SHALL BE AS PER APPLICABLE ARTICLES OF THE NATIONAL ELECTRICAL CODE. COORDINATE WITH SPECIFICATIONS FOR DEVICE REQUIREMENTS. 11. THE ENTIRE INSTALLATION MUST BE GROUNDED IN COMPLIANCE WITH THE NATIONAL ELECTRICAL CODE. ALL DEVICES, EQUIPMENT BOXES, ETC. MUST BE CONNECTED TO A SOLID, INSULATED GREEN, COPPER GROUNDING CONDUCTOR. THIS GROUNDING CONDUCTOR MUST BE CONTINUOUS WITHOUT SPLICES FROM POINT OF ORIGIN IN PANELBOARD TO ALL BOXES AND EQUIPMENT ON EACH BRANCH CIRCUIT. VERIFY GROUNDING VALUES AND SUBMIT A TYPEWRITTEN REPORT TO THE ARCHITECT INDICATING TESTING RESULTS OF EACH CIRCUIT AT THE COMPLETION OF THE PROJECT. 12. FOR SINGLE PHASE CIRCUITS, UNLESS NOTHER OTHERWISE, NEW WIRING INDICATED SHALL BE (2) #12 & (1) #12 GROUND IN 3/4" CONDUIT. FOR CIRCUITS THAT REQUIRE LONG TRAVEL DISTANCES, REFER TO VOLTAGE DROP NOTE BELOW. 13. ALL NEW CONDUITS INSTALLED UNDER THIS PROJECT MUST BE INSTALLED AS HIGH AS POSSIBLE AND INSTALLED AROUND EXISTING BEAMS. 14. FIRESTOP ALL CONCEALED AND ACCESSIBLE CONDUITS WITHIN THE CONTRACT WORK AREA. FIRESTOP ALL CONDUITS AS PART OF THE NEW CONSTRUCTION. 15. PROVIDE AND INSTALL APPROVED FIRE STOPPING AT ALL FLOOR SLAB/CEILING AND WALL PENETRATIONS TO MAINTAIN THE FIRE RATED CONSTRUCTION. 16. RECEPTACLES SHALL BE PROVIDED WITH ARC-FAULT CIRCUIT INTERRUPTER PROTECTION WHERE REQUIRED BY APPLICABLE CODES. GENERAL ELECTRICAL NOTES: VOLTAGE DROP NOTE: THE FOLLOWING LIST APPLIES TO ALL NEW BRANCH WIRING PROVIDED UNDER THIS CONTRACT. LISTS INDICATE THE NECESSARY GAUGE OF CONDUCTORS FOR BRANCH CIRCUITS ONE WAY FROM PANEL TO LAST OUTLET OR LIGHTING FIXTURE ON THE CIRCUIT. 120/240V CIRCUITS WIRE SIZE · 0-100 FEET No. 12 AWG · 101-250 FEET No. 10 AWG · 250-400 FEET No. 8 AWG FIRE ALARM ANNUNCIATOR PANEL FIRE ALARM SYSTEM AUDIO/VISUAL TYPE HORN W/ADA STROBE FIRE ALARM SYSTEM SMOKE/CARBON DIOXIDE COMBO DETECTOR - PHOTO-ELECTRIC FIRE ALARM SYSTEM - FLOW SWITCH FOR SPRINKLER SYSTEM INDIVIDUAL ADDRESSABLE MODULE FIRE ALARM SYSTEM MANUAL PULL STATION FIRE ALARM SYSTEM SMOKE DETECTOR - PHOTO-ELECTRIC FIRE ALARM SYSTEM STROBE FIRE ALARM SYSTEM - SUPERVISED VALVE FOR SPRINKLER SYSTEM FIRE ALARM SYSTEM CONTROL PANEL FIRE ALARM SYSTEM HEAT DETECTOR FIRE ALARM SYSTEM - TAMPER SWITCH FOR SPRINKLER SYSTEM FIRE ALARM SYSTEM LEGEND BOLLARD LIGHTING LEGEND DOUBLE SPOT LIGHT RECESSED MOUNTED DOWN LIGHT TYPE FIXTURE FAN LIGHT FLOOD LIGHT FLOOD LIGHT FIXTURE HID LIGHT FIXTURE - POST MOUNTED PENDANT MOUNTED LIGHT FIXTURE - CEILING MOUNTED SCONCE TYPE FIXTURE SINGLE SPOT LIGHT SINGLE SPOT LIGHT SURFACE MOUNTED DOWN LIGHT TYPE FIXTURE TRACK LIGHTING FIXTURE BRACKET OR SCONCE TYPE FIXTURE DOWN LIGHT WALL WASH TYPE FIXTURE TIME CLOCK LIGHTING CONTROLS LEGEND CEILING MTD OCCUPANCY SENSOR PHOTO CELL POWER LEGEND CONNECTION TO VARIABLE VOLUME BOX BY EC CONNECTION TO AIR COOLED CONDENSING UNIT BY EC BACK BOX FINAL CONNECTION BY EC TO DISHWASHER - 120V-1Ø COMBINATION DISCONNECT SWITCH AND STARTER CONNECTION TO SOLENOID VALVE BY EC FUSED DISCONNECT SWITCH NON-FUSED DISCONNECT SWITCH ELECTRIC THERMOSTAT BY OTHERS UNLESS NOTED OTHERWISE AND WIRED BY EC POWER ENCLOSED CIRCUIT BREAKER AUTOMATIC TRANSFER SWITCH FINAL CONNECTION BY EC TO EQUIPMENT HAND DRYER, 48" ABOVE FINISHED FLOOR, UNLESS NOTED OTHERWISE HORIZONTAL UNIT HEATER - 1-60-120V - UNO JUNCTION BOX MOTOR MOTOR OPERATED DAMPER TRANSFORMER RECEPTACLES LEGEND COMBINATION DUPLEX RECEPTACLE/INFORMATION OUTLET FLUSH MOUNTED IN FLOOR DOUBLE DUPLEX RECEPTACLE DUPLEX RECEPTACLE DUPLEX RECEPTACLE - ABOVE COUNTER DUPLEX RECEPTACLE - MOUNTED FLUSH IN FLOOR (SEE DETAIL) DUPLEX RECEPTACLE - POKE-THRU (SEE DETAIL) DUPLEX RECEPTACLE CONNECTED TO EMERGENCY POWER SYSTEM DUPLEX GROUND FAULT INTERRUPTER TYPE RECEPTACLE SINGLE RECEPTACLE DUPLEX, TAMPER RESISTANT, GROUNDING TYPE RECEPTACLE TELEVISION POWER OUTLET - 12" BELOW CEILING UNO 3-WAY SWITCH SWITCH LEGEND 4-WAY SWITCH LOWER CASE LETTER INDICATES FIXTURES CONTROLLED IN SWITCH GROUP IN WALL-TYPE DIMMER, RATING AS NOTED DOUBLE POLE SWITCH SINGLE PHASE MANUAL MOTOR SWITCH WITH OVERLOADS OCCUPANCY SENSOR SWITCH SWITCH WITH PILOT LIGHT (PILOT LIGHT IS ON WHEN SWITCH IS IN OFF POSITION) SINGLE POLE SWITCH DATA OUTLET TELECOMMUNICATIONS LEGEND COMMUNICATION OUTLET DATA/TELEPHONE OUTLET MOUNTED FLUSH IN FLOOR TELEPHONE OUTLET - MOUNTED 18" ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED WALL TELEPHONE OUTLET TELEVISION OUTLET - MOUNTED 12" BELOW FINISHED CEILING, UNLESS OTHERWISE NOTED CT ANN F F S F FS IAM F F F SV FACP F H F TS F L P OS 3 4 a D 2 OS M PL VVB ACCU ADO BB DW SV CB ATS HD M HUH J M M FCU M MOD T AUTOMATIC DOOR OPERATOR FAN COIL UNIT - 1-60-120V - UNO F P SPECIAL PURPOSE RECEPTACLE DUPLEX GROUND FAULT INTERRUPTER RECEPTACLE ABOVE COUNTER 2 AB GFI TR TV AB GFI W VT WAP WIRELESS ACCESS POINT DATA OUTLET TYPICAL FLUORESCENT PENDANT MOUNTED FIXTURE TYPICAL FLUORESCENT RECESSED FIXTURE TYPICAL FLUORESCENT SURFACE MOUNTED FIXTURE TYPICAL FLUORESCENT WALL MOUNTED FIXTURE MISCELLANEOUS ELECTRICAL LEGEND INDICATES NOTES ELSEWHERE PHASE SWITCH LEG BRANCH CIRCUIT SWITCHED CIRCUIT HOMERUN TO PANEL BOARD - 3 #12-3/4"C UNO ELECTRICAL PANEL BOARD - SURFACE MOUNTED Ø F S DOUBLE FACE EXIT SIGN SINGLE FACE EXIT SIGN TYPICAL FLUORESCENT RECESSED EMERGENCY FIXTURE DUAL HEAD EMERGENCY LIGHT 1 ELECTRICAL PANEL BOARD - RECESSED CO2 DUPLEX RECEPTACLE W/ TWO INTEGRAL USB PORTSUSB DUPLEX GFCI TYPE RECEPTACLE MOUNTED IN WEATHERPROOF "WHILE-IN-USE" COVER WPGFI FINAL CONNECTION BY EC TO ELECTRIC FIREPLACE - 120V-1ØFP FINAL CONNECTION BY EC TO GARBAGE DISPOSAL - 120V-1ØGD FINAL CONNECTION BY EC TO UNDERCOUNTER ICE MACHINE - 120V-1ØICE FINAL CONNECTION BY EC TO ELECTRIC WALL HEATER - 208V-1Ø EWH SCALE: PROJECT NUMBER: PLOT DATE: 757 FREDERICK ROAD SUITE 202 CATONSVILLE, MD 21228 (410)461-7763 JSRASSOCIATES.NET JANE@JSRASSOCIATES.NET STATUS: REVISION LOG REV # DATE DESCRIPTION DRAWN BY: SHEET NO. SHEET NAME BUILDER: E001 H.F. LENZ COMPANY Engineering 1407 Scalp Avenue Johnstown, PA 15904 P: 814.269.9300 www.hflenz.com Headquarters: 2020-0450.01 12/21/2020 1/8" = 1'-0" ELECTRICAL NOTES, SYMBOLS, & ABBREVIATIONS WSP PERMITJames Miles2080 W 106th Street, Carmel, IN 46032Willow Haven Senior Homes08/09/21 F F F FF F F F F F F F F F F F F F F FACP PANEL LP, 240/120-1Ø-3W PANEL EM, 240/120-1Ø-3W, GENERAC, 24 POLE, TRANSFER SWITCH & LOAD CENTER FS FS ABGFI ABGFI ABGFI AB GFI ABGFIABGFI ABGFI ABGFI ABGFI ABGFI ABGFIABGFI RP-1 RP-1 RP-1RP-1 RP-1 RP-2 RP-2 RP-2 RP-2 RP-1 HOME OFFICE LAUNDRY FLEX SPACE PWDR RM LIBRARY MECH PANTRY SRR HK SLEEPING ROOM VT TVTV V T VT TV VT TV V T TV V T TV V T TV V T TV V T TV VT TV F F FF F F F F F 30A GFI 30A GFI AFF GFI 44" USB USB USB USB USB USB USB USB USB USB USB V T TV DW DW FP VT TV F F IAM IAM FIRE ALARM SYSTEM SUPERVISED VALVES G GENERAC, 19.5 kW, NATURAL GAS GENERATOR LOCATED UNDER DECK. CONTRACTOR SHALL CONFIRM WITH AHJ AND GENERATOR MANUFACTURER THAT LOCATION IS ACCEPTABLE AND THAT ALL REQUIRED CLEARANCES ARE MET. WPGFI F F F F F F F F WPGFI WPGFIWPGFI 1 2 3 KITCHEN BATHBATH BATH BATH BATH BATH BATH BATH BATH BATH REF REF ICE ABGFI ABGFI ABGFIABGFI AB AB WPGFI 10-POLE CONTACTOR BEF-1 EWH-1 EWH-1 AHU-1 AHU-2 AHU-3ACCU-1 ACCU-2 ACCU-3 WP WP WP ELECTRIC WALL HEATER (TYP) 5 108 SLEEPING ROOM 111 SLEEPING ROOM 109 SLEEPING ROOM 107 SLEEPING ROOM 106 SLEEPING ROOM 105 SLEEPING ROOM 104 SLEEPING ROOM 103 SLEEPING ROOM 102 SLEEPING ROOM 101 LIVING ROOM DINING ROOM ACTIVITY AREA ENTRY EWH-1 CABLE TV AND WIFI HEAD END EQUIPMENT SHALL BE LOCATED ON WALL WITHIN ROOM. COORDINATE EXACT LOCATION WITH OWNER. KEYNOTES ELSEWHERE THIS DRAWING: 1 2 3 COORDINATE FINAL SINK AND ICE MAKER LOCATIONS W/ SHOP DRAWINGS. COORDINATE FINAL LOCATION AND MOUNTING HEIGHT OF RECEPTACLES FOR MICROWAVE AND WALL OVEN W/ SHOP DRAWINGS. 4 SOLATUBE. NO POWER REQUIRED. 5 COORDINATE FINAL LOCATION AND MOUNTING HEIGHT OF RECEPTACLE FOR INDUCTION COOKTOP W/ SHOP DRAWINGS. HOME OFFICE LAUNDRY GREETING RM MECH PANTRY SRR HK KITCHEN BATHBATHBATH BATH BATH BATH BATH BATH BATH BATH LF-7LF-7LF-7 LF-5 LF-4 LF-6 LF-4 LF-6 LF-5 LF-5 LF-4 LF-6 LF-4 LF-6 LF-5 LF-6 LF-5LF-5 LF-6 LF-2LF-2 LF-2LF-2 LF-2 LF-1 LF-2 LF-7LF-7 LF-7 LF-1 LF-1 LF-1LF-1 LF-2 LF-1 LF-1 LF-1 LF-1 LF-2 LF-5 LF-4 LF-6 LF-4 LF-6 LF-5 S LF-5 SS LF-5 LF-13 OSLF-13 LF-13 SPANEL LP, 240/120-1Ø-3W PANEL EM, 240/120-1Ø-3W, GENERAC, 24 POLE, TRANSFER SWITCH & LOAD CENTER LF-13SSLF-6 LF-4 LF-6 LF-4 LF-1 LF-2 LF-2 LF-2A LF-1 LF-1 LF-1 LF-1 LF-1 LF-2A LF-1 LF-1 LF-9 LF-1 LF-10 LF-1 LF-1 LF-1 LF-8 LF-810-POLE CONTACTOR LF-6A LF-6A LF-6B S LF-1A LF-1A LF-1A LF-1A LF-1A OS OS LF-1LF-1 LF-1 LF-1 SLF-1 LF-1 LF-1 LF-1 LF-11 LF-11 CT LF-1 LF-10 LF-10 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-9 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-9 LF-1 LF-1 LF-1 LF-2A LF-1LF-1 LF-1 LF-1 LF-1 LF-1 LF-1A LF-1A LF-1A LF-1ALF-1ALF-1A LF-1A LF-1A LF-1A LF-1A LF-4LF-4 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-18 LF-18 LF-18 LF-18 LF-18 LF-18 LF-18 LF-18 LF-18 LF-11 LF-11 4 4 4 4 4 LF-3 LF-3 LF-3 LF-3 LF-3LF-8LF-8LF-8 LF-8L F - 8 LF-8 LF-8LF-8FLEX SPACE LIVING ROOM DINING ROOM ACTIVITY AREA ENTRY SLEEPING ROOM 106 SLEEPING ROOM 105 SLEEPING ROOM 104 SLEEPING ROOM 103 SLEEPING ROOM 102 SLEEPING ROOM 101 SLEEPING ROOM 108 SLEEPING ROOM 107 SLEEPING ROOM 111 SLEEPING ROOM 109 LF-14 LF-14 SLEEPING ROOM LF-7 LF-1LF-1 LF-1 LF-1 LF-2 SSTO RESIDENT BATH LTG CKT TO 20A-1P-CB IN PNL LP OR NEXT RESIDENT RM LF-818" SEE FULL PLAN FOR ALL LOCATIONS FIXTURE PROVIDED W/ ON / OFF MOTION SENSOR. BATH LF-5 LF-4 LF-6 SSSOS S TO RESIDENT RM LTG CKT (TYP) SHOWER LT SW NIGHTLIGHT SW ROOM LT SW FAN SW HEATER SW S SCALE: PROJECT NUMBER:PLOT DATE: 757 FREDERICK ROAD SUITE 202 CATONSVILLE, MD 21228 (410)461-7763 JSRASSOCIATES.NET JANE@JSRASSOCIATES.NET STATUS: REVISION LOG REV # DATE DESCRIPTION DRAWN BY: SHEET NO. SHEET NAME BUILDER: E101 H.F. LENZ COMPANY Engineering 1407 Scalp Avenue Johnstown, PA 15904 P: 814.269.9300 www.hflenz.com Headquarters: 2020-0450.01 12/21/2020 1/8" = 1'-0" FIRST FLOOR POWER PLAN WSP PERMIT 2 ELECTRICAL - FIRST FLOOR PLAN - POWER & SIGNAL Scale: 1/8" = 1'-0"4' 8' 16'0 1 ELECTRICAL - FIRST FLOOR REFLECTED CEILING PLAN - LIGHTING Scale: 1/8" = 1'-0"4' 8' 16'0 3 TYPICAL BATH LTG FLOOR PLAN Scale: 1/4" = 1'-0" 4 TYPICAL SLEEPING RM LTG FLOOR PLAN Scale: 1/4" = 1'-0" 0 2' 4' 8' 0 2' 4' 8' James Miles2080 W 106th Street, Carmel, IN 46032Willow Haven Senior Homes08/09/21 LINE VOLTAGE CEILING SENSOR (DUAL TECH)5 NOT TO SCALE W/ DUAL TECHNOLOGY CEILING SENSOR LINE VOLTAGE WHITE SWITCH BLACK LOAD H N BLACK LINE VOLTAGE WALL SWITCH SENSOR (DUAL TECH) 4 NOT TO SCALE WALL SWITCH SENSOR GREEN BLACK LOAD BLACK H N W/ DUAL TECHNOLOGY TYPICAL FIRE ALARM RISER DIAGRAM 1 NOT TO SCALE TYPICAL FIRE ALARM DEVICE MOUNTING DETAIL2 NOT TO SCALE FIRE FIRE FIRE ALARM PULL DOWN 4" WALL MOUNTED SMOKE/HEAT DETECTOR NEVER HERE 12" MAX CEILING MOUNTED SMOKE/HEAT DETECTOR 24" TO TOP OF LENS. MIN DISTANCE HANDICAP BEDROOM STROBE SYNCHRONIZE MORE THAN TWO APPLIANCES IN ANY FIELD OF VIEW 80" (ADA)80" (MIN NFPA)AUDIO/VISUAL (A/V) AND VOICE ONLY (V/O) DEVICES MANUAL PULL STATION 48" MAX (ADA)42" MIN/54" MAX(NFPA)FINISHED FLOOR SIDE WALL 96" MAX (NFPA) AFF FIREMANS PHONE JACK CEILING MAGNETIC DOOR HOLDER 6" DOOR WIDTH LESS 3" TO EXIT DOOR 5' MAX FINISHED WALL 3' MIN 4" A/C SUPPLY OR RETURN DIFFUSER ACCEPTED HERE NOTE: MEASUREMENTS SHOWN ARE TO THE CLOSEST EDGE OF THE DETECTOR 80" MIN (IBC)96" MAX (IBC)NOTE: REFER TO THE PROPER DEVICE INSTALLATION INSTRUCTIONS FOR BACKBOX MOUNTING HEIGHT. NUMBER OF CONDUCTORS AS REQ'D BY EQUIPMENT MANUFACTURER (NORMAL-EMERGENCY) 120V CIRCUIT ADDRESSIBLE INPUT MODULE (IAM) 1 #18 (TWISTED/SHIELDED PAIR)-1/2"C 2 #12 (THHN)-1/2"CB IAM A B A F F S IAM F FS FSV IAM B F A A A A C C A 1 #18 (TWISTED/SHEILDED PAIR)X AND 2 #14 (THHN)-1/2"C C MAIN FIRE ALARM CONTROL PANEL END OF LINE RESISTOR ANN X C F F S FIRE ALARM CONTROL PANEL PROVIDE AT LOCATION OF MAIN TO LOCAL INITIATION CIRCUIT.A 1. PULL STATIONS, SMOKE DETECTORS, HEAT DETECTORS SHALL BE ADDRESSIBLE. 2. PROVIDED GALVANIZED INTERLOCKING STEEL STRIP (RED STRIPED) TYPE MC CABLE FOR ALL FIRE ALARM CIRCUITS. CABLE ASSEMBLY SHALL BE UL LISTED FOR FIRE ALARM CIRCUIT APPLICATIONS. 3. CABLE SIZE AND QUANTITY SHOWN FOR DIAGRAMMATICAL PURPOSES ONLY, PROVIDE ONLY MANUFACTURERS RECEMMENDED CABLING. F S F S TO ADDITIONAL DEVICES. CONSULT MANUFACTURER ON NUMBER OF CIRCUITS REQUIRED. TO ADDITIONAL DEVICES. CONSULT MANUFACTURER ON NUMBER OF CIRCUITS REQUIRED. TYPICAL BATHROOM SWITCH FACEPLATE LAYOUT 3 NOT TO SCALE NIGHTLIGHTOVERHEAD/ MIRROR FAN OCCUPANCY SENSOR CONTACT WIRING DIAGRAM 6 NOT TO SCALE J RP-2 SLEEPING RM J RP-1 SLEEPING RM J RP-2 SLEEPING RM J RP-2 SLEEPING RM J RP-1 SLEEPING RM J RP-2 SLEEPING RM J RP-1 J RP-1 J RP-1 J RP-1 SPARE SPARE RELAY DIGITAL TIME CLOCK TORK (NSI INDUSTRIES) CAT. No. DGM100A 120V-1Ø HOT NEUTRAL 10-POLE CONTACTOR EATON, CAT No. ECC04C1AAA ELECTRICALLY OPERATED/ MECHANICALLY HELD 240V-1Ø, BRANCH CIRCUITS CONTROLLED BY CONTACTOR SLEEPING RM SLEEPING RM SLEEPING RM SLEEPING RM SCALE: PROJECT NUMBER:PLOT DATE: 757 FREDERICK ROAD SUITE 202 CATONSVILLE, MD 21228 (410)461-7763 JSRASSOCIATES.NET JANE@JSRASSOCIATES.NET STATUS: REVISION LOG REV # DATE DESCRIPTION DRAWN BY: SHEET NO. SHEET NAME BUILDER: E501 H.F. LENZ COMPANY Engineering 1407 Scalp Avenue Johnstown, PA 15904 P: 814.269.9300 www.hflenz.com Headquarters: 2020-0450.01 12/21/2020 1/8" = 1'-0" ELECTRICAL DETAILS WSP PERMITJames Miles2080 W 106th Street, Carmel, IN 46032Willow Haven Senior Homes08/09/21 LIGHTING NOTES: 1. WALA LAMPS SHALL BE CONTROLLED THROUGH ONLINE APP. 2. CONTRACTOR SHALL PERFORM LIGHTING CALCULATIONS TO CONFIRM ALL LIGHTING LEVELS ARE AS REQUIRED BY THE ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA (IESNA) AND ALL APPLICABLE CODES. SCALE: PROJECT NUMBER: PLOT DATE: 757 FREDERICK ROAD SUITE 202 CATONSVILLE, MD 21228 (410)461-7763 JSRASSOCIATES.NET JANE@JSRASSOCIATES.NET STATUS: REVISION LOG REV # DATE DESCRIPTION DRAWN BY: SHEET NO. SHEET NAME BUILDER: E601 H.F. LENZ COMPANY Engineering 1407 Scalp Avenue Johnstown, PA 15904 P: 814.269.9300 www.hflenz.com Headquarters: 2020-0450.01 12/21/2020 1/8" = 1'-0" ELECTRICAL SCHEDULES & DIAGRAMS WSP PERMITJames Miles2080 W 106th Street, Carmel, IN 46032Willow Haven Senior Homes08/09/21