Loading...
HomeMy WebLinkAboutA211 FINISH PLAN - DOOR SCHEDULE INTERIOR DETAILSEXIST 4"V. EXIST 4"W. 2"W. F.F. 2"W. 2"W. SINK TO BUILDING DRAIN F.F. 112"V. CLG. 112"V. CLG. TO EXISTING STACK NOTE: REFER TO FLOOR PLAN AND CASEWORK ELEVATION(S) FOR SINK LOCATION(S) F2 4'-4" 2"REFER TO DOOR SCHED. 2"F1 3'-0" 3'-4" 2" 2"REFER TO DOOR SCHED. 2"F4 2" F3 6'-6" 3'-0" 2" REFER TO DOOR SCHED. 2"2" 3'-0" 2" 14" TEMPERED GLASS 4'-0" 5'-6" 3'-0" 2" REFER TO DOOR SCHED. 2"2" 2'-0" 2" 14" TEMPERED GLASSREFER TO DOOR SCHED.D1 3'-0"1'-0" 8"7" 7" REFER TO DOOR SCHED.3'-0" D2 D3 14" TEMPERED GLASS, WOOD FLUSH BEAD STAINED TO MATCH DOOR 1'-0" 8"7" 7"REFER TO DOOR SCHED.2'-0" 14" TEMPERED GLASS, WOOD FLUSH BEAD STAINED TO MATCH DOOR TV DWMICRODW WELCOME 101 COATS 102 WORK/COPY 105 OPEN OFFICE 113 BREAK 112 OFFICE 104 SERVER/ STORAGE 106 OFFICE 107 OFFICE 108 OFFICE 109 OFFICE 110 OFFICE 111 STG. 114 SHOWROOM 115 MEET 103REFRIGBYTENANT REFRIGBYTENANTBUILDING SERVICE 116 DOOR SCHEDULE INTERIOR DETAILS A211 DESCRIPTIONDATE ISSUE 06.18.21 REVIEW SET 06.24.21 PERMIT SET 07.22.21 CARMEL PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR EPCONTWO PENN MARK - SUITE 15011555 N MERIDIAN ST - CARMEL, IN 46032EHEH 2021.093 1ST FLOOR FINISH PLAN NOTES AREA NOT IN CONTRACT AREA OF WORK FINISH PLAN FINISH PLAN/ CASEWORK NOTES PROVIDE JOHNSONITE SLIMLINE SLT-XX-F PROFILE TRANSITION STRIP AT FLOORING TRANSITION; COLOR: TBD. CONTRACTOR MUST PROVIDE LEVELING LATEX SUCH THAT HEIGHTS OF MATERIALS ARE APPROPRIATE FOR USE WITH SPECIFIED PROFILE TRANSITION. BE AWARE TRANSITION STRIP MUST BE ORDERED IN A TIMELY MANNER AS IT IS NOT ALWAYS IMMEDIATELY AVAILABLE. TENANT + TENANT'S MILLWORKER TO PROVIDE AND INSTALL WOOD "HOUSE" CROWN MOLDING + BASE TRIM. CONTRACTOR TO PAINT PT_. NO FINISH WORK IN THIS AREA. TOUCH UP/PATCH FITNESS CENTER FINISHES ONLY AS REQUIRED. TYPICAL ALL SINGLE LOCATIONS,NOT TO SCALE RISER DIAGRAM A211 1 0 2' 4' 8' 16' HARDWARE LEGEND R1. PROVIDE BULLET CATCHES AT TOP OF EACH DOOR; FINISH TO MATCH REMAINDER OF DOOR HARDWARE. R2. MODIFY EXISTING SOLID DOOR TO MATCH DOOR TYPE "D2". SALVAGE 12"X12" PORTION OF DOOR CUT-OUTS FOR TENANT'S DESIGNER'S REFERENCE. R3. FINISH TENANT SIDE OF DOOR AND FRAME TO MATCH SUITE STANDARD STAIN COLOR. FINISH CORRIDOR SIDE OF DOOR AND FRAME TO MATCH BUILDING STANDARD STAIN COLOR IN PUBLIC CORRIDORS. R4. ENSURE RELOCATED DOOR + NEW DOOR FRAME FINISHES MATCH REMAINDER OF FITNESS CENTER SUITE. COORDINATE WITH PROPERTY MANAGEMENT FOR SPECIFICATIONS AS NEEDED. R5. ALL EXISTING HARDWARE TO REMAIN. PROVIDE POWER + NEW MAGLOCK. CARD READER BY TENANT. REMARKS DOOR/FRAME TYPES CARPET FLOOR COVERINGS MFG: TBD TYPE: -- PATTERN: -- COLOR: -- INSTALL: -- VINYL COMPOSITION TILE MFG: TBD SIZE: 12"x12" PATTERN: -- COLOR: -- WALL BASE MFG: TBD TYPE: 4" VINYL COVE, 18" GAUGE COLOR: -- WOOD BASE SIZE: 4" TYPE: -- ALL FINISHES SHALL MEET ALL CLASS A FIRE RATINGS AND COMPLY WITH CHAPTER 8 OF INTERNATIONAL BUILDING CODE. FINISH LEGEND MFG: TBD SIZE: -- COLOR: -- GROUT: EQUAL TO TEC 550 POWER GROUT; JOINT TO BE 18"; COLOR: -- LUXURY VINYL TILE NOTE: AT ALL LVT LOCATIONS, PROVIDE SKIMCOAT OF ARDEX LEVELING LATEX AS NEEDED FOR SMOOTH SUBFLOOR THAT WILL NOT ALLOW FOR TELEGRAPHING OF IMPERFECTIONS IN THE FLOOR 1. REFER TO LEGEND FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. 2. CONTRACTOR TO EVALUATE EXISTING FLOORING CONDITIONS AFTER DECONSTRUCTION IS COMPLETE AND PREP AS NECESSARY PER MANUFACTURERS RECOMMENDATIONS. SEALCOAT THE CONCRETE FLOOR PRIOR TO LAYING ADHESIVE IF DEEMED NECESSARY. 3. AT ALL FLOOR TILE LOCATIONS PROVIDE WATERPROOFING CRACK ISOLATION MEMBRANE:  TEC HYDRAFLEX FULL COVERAGE PER TCNA F125-11 FULL. PROVIDE CONTROL JOINTS EVERY 12' AT MINIMUM OR AS RECOMMENDED BY MANUFACTURER. 4. AT NEW WALL TILE LOCATIONS PROVIDE APPROPRIATE SUBSTRATE FOR WALL TILE (AT EXISTING WALLS SCHLUTER KERDI BOARD OR EQUAL) (AT NEW WALLS CEMENT BACKER BOARD) AS RECOMMENDED BY MANUFACTURER. 5. IF FINISH SUBMITTALS ARE REQUESTED AS PART OF THIS SCOPE, THEY ARE TO BE SUBMITTED IN DIGITAL FORMAT. 6. ALL FLOORING AND WALL BASE TO BE PROVIDED AND INSTALLED BY TENANT'S VENDOR. COORDINATE AS REQUIRED. GENERAL FINISH NOTES WALL FINISHES MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: -- FINISH: EGGSHELL CASEWORK FINISHES MFG: TBD COLOR: -- MFG: TBD COLOR: -- MFG: TBD COLOR: -- MFG: TBD COLOR: -- MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: -- FINISH: EGGSHELL MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: -- FINISH: EGGSHELL PAINT PLASTIC LAMINATE SOLID SURFACE CARPET NOTE: ALL MANUFACTURERS PARTICIPATES IN SCHOTT DESIGN'S RECYCLING NO COST ADD TO CLIENT OR PROJECT PROCESS. REFER TO SCHOTT DESIGN DECONSTRUCTION NOTES ON T111 AND D111 FOR PROCESS DETAILS. MFG: TBD SIZE: --X--, XX THICK PATTERN: -- COLOR: -- INSTALL: -- GENERAL NOTE: CONTRACTOR TO COORDINATE WITH TENANT'S MILLWORKER AS REQUIRED + CONFIRM THAT SINKS NOTED IN ELEVATIONS PROPERLY COORDINATE WITH WIDTH AND DEPTH OF BASE CABINET PRIOR TO ORDERING. ALL CABINETRY + MILLWORK PROVIDED BY TENANT AND MUST COMPLY WITH ADA AND ALL STATE + LOCAL CODES. DOOR/FRAME NOTES 1. REUSE DOORS FROM DECONSTRUCTION WHERE POSSIBLE; TOUCH UP EXISTING DOOR STAIN AS REQUIRED. PROVIDE NEW BUILDING STANDARD DOORS MATCHING EXISTING VENEER AS REQUIRED. STAIN NEW DOORS TO MATCH EXISTING. PRE-MACHINE NEW DOORS FOR CYLINDRICAL LOCKSETS. 2. PROVIDE NEW HARDWARE TO MATCH EXISTING ON NEW DOORS. REUSE EXISTING HARDWARE ON EXISTING DOORS WHERE POSSIBLE. FOR NEW DOOR HARDWARE, PROVIDE GRADE 2 MINIMUM BUILDING STANDARD. PROVIDE ADA ACCESSIBLE LEVER HANDLES ON NEW LOCK AND LATCHSETS. 3. PROVIDE NEW BUILDING STANDARD FRAMES AS REQUIRED. REUSE EXISTING FROM DEMOLITION WHERE POSSIBLE. CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXISTING WALL STUD SIZE ALLOWS FRAMES TO BE REUSED WITH NEW WALL CONSTRUCTION. IF FRAMES ARE NOT BEING REPAINTED, TOUCH UP EXISTING FRAMES TO BE REUSED. 4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL CORNERS UNLESS OTHERWISE NOTED ON PLAN. 5. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND LOCKSETS. 6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION, PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES. ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS. 7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS: · 7'-0" HT. TO HAVE 3 HINGES · GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES · FINISH TO MATCH HARDWARE SET 8. PROVIDE (1) SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE NOTED. 9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT EACH DOOR UNLESS OTHERWISE NOTED. PROVIDE BLOCKING BEHIND WALL STOP. DOOR SCHEDULE # DIMENSIONS DOOR FRAME HARDWARE REM. 01A R5 01B R1 01C R2 02 03A R2 03B 04 R2 05 R3 06 07 R2 08 R2 09 R2 10 R2 11 R2 14 16 R4 TYPE MATERIAL FINISH TYPE MATERIAL FINISH -- -- -- -- -- -- -- EL, CR 2'-0"x9'-0"x13 4" (PAIR) D3 SOLID CORE MATCH EXIST. F3 HOLLOW METAL MATCH EXIST.RL, DL EXISTING NEW SWING -- -- CL CLOSER CH COAT HOOK CR CARD READER BY TENANT (N.I.C.) DB DEADBOLT DL DUMMY LEVER EL ELECTROMAGNETIC LOCK (PER IBC 2012) ES ELECTRIC STRIKE BY TENANT (N.I.C.) FP FOOT PULL - STEP N PULL HANDS FREE DOOR OPENER SNPE-B H HOLD OPEN KP KICK PLATE KS KICK STOP OL OFFICE LOCKSET PH PANIC HARDWARE PL PRIVACY LOCKSET PP PUSH/PULL PS PASSAGE LATCHSET PV PIVOT HINGE RL ROLLER LATCHES SL STOREROOM LOCKSET TS TOP STRIKES -- -- -- -- -- -- -- --EXISTING -- -- -- -- -- -- -- -- CR, ES, SL, CLEXISTING -- -- -- -- -- -- -- -- CR, ES, SL, CLEXISTING -- STAIN TO MATCH EXIST. 3'-0"x9'-0"x13 4" -- -- -- F1 HOLLOW METAL MATCH EXIST.CR, ES, SL, CLRELOCATED RH 3'-0"x9'-0"x13 4" -- -- -- F2 HOLLOW METAL MATCH EXIST.PSRELOCATED RH 3'-0"x9'-0"x13 4" -- -- -- F1 HOLLOW METAL MATCH EXIST.CR, ES, SL, CLRELOCATED LH 3'-0"x9'-0"x13 4" -- -- -- F2 HOLLOW METAL MATCH EXIST.PSRELOCATED LH 3'-0"x9'-0"x13 4" -- -- -- F4 HOLLOW METAL MATCH EXIST.PSRELOCATED LH 3'-0"x9'-0"x13 4" -- -- -- F2 HOLLOW METAL MATCH EXIST.PSRELOCATED RH 3'-0"x9'-0"x13 4" -- -- -- F2 HOLLOW METAL MATCH EXIST.PSRELOCATED RH 3'-0"x9'-0"x13 4" -- -- -- F2 HOLLOW METAL MATCH EXIST.PSRELOCATED RH 3'-0"x9'-0"x13 4" -- -- -- F1 HOLLOW METAL MATCH EXIST.PSRELOCATED LH 3'-0"x9'-0"x13 4" -- -- -- F1 HOLLOW METAL MATCH EXIST.PSRELOCATED LH 3'-0"x9'-0"x13 4" -- -- -- F1 HOLLOW METAL MATCH EXIST.SL, CLRELOCATED RH HARDWOOD MFG: TBD TYPE: -- PATTERN: -- COLOR: -- INSTALL: -- 08/13/21