Loading...
HomeMy WebLinkAboutA111 Architectural PlanWALL THICKNESS PRE-FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT METAL STUD EXISTING WINDOW MULLION EQUAL OFFICE 205 OFFICE 213 OFFICE 206 OFFICE 207 MEET 212 ENTRY / COLLABORATION 201 STORAGE 202 CONFERENCE 203 CAFE 209 STG. 214 COLLAB/ FOCUS 208 OPEN OFFICE 210 PHONE RM. 204 PHONE RM. 211 9'-014"10'-5"10'-5" 10'-5" 5'-0"CLEAR9'-11"6'-10" 7'-71 2" CLEAR 3'-5"10'-5" 10'-5" 11'-0" 4'-5" 12'-0" 12'-0"7'-1" 12'-1112"2'-11" FE6'-034"12 0 °DW2'-51 2" 6'-111 2" 3'-111 4"150°8"2'-812"ARCHITECTURAL FLOOR PLAN A111 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. EXISTING COLUMN TO REMAIN EXPOSED. CLEAN AS NECESSARY AND PREP FOR PAINT; SEE FINISH PLAN FOR MORE INFORMATION. NEW BRUSHED ALUMINUM RECESSED CABINET AND FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. WRAP EXISTING COLUMN AS TIGHTLY AS POSSIBLE. IN AREA WITH EXPOSED CEILING DECK, PROVIDE DRYWALL ALONG EXTERIOR WALL, EXTENDING TO DECK. TRANSITION TO BE A CLEAN HORIZONTAL LINE FINISHED SUCH THAT CONTRASTING PAINT COLORS CAN EASILY AND CLEANLY CUT AT WALL TO CEILING LINE. SEE REFLECTED CEILING PLAN FOR EXACT AREA OF EXPOSED CEILING. PROVIDE 8'-0"H WINDOW WITH TIMELY FRAME TO MATCH DOOR FRAMES, FULL WIDTH OF WALL WITH 38" TEMPERED GLASS. _______________________________________________________________ PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. WATER HEATER TO BE LOCATED UNDER COUNTER WITH DRAIN PAN; CONTRACTOR TO INSTALL AUTOMATIC SHUTOFF VALVES. PROVIDE WATER LINE FOR REFRIGERATOR. CONFIRM LOCATION WITH TENANT. PROVIDE ALL NECESSARY PLUMBING AND DRAINS FOR TENANT'S DISHWASHER AT THIS LOCATION. PLAN NOTES ARCHITECTURAL PLAN WALL DOOR AND FRAME (SEE DOOR SCHEDULE) NEW CONSTRUCTION EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHTWINDOW / SIDELIGHT ARCHITECTURAL LEGEND PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL WALL TO DECK WITH INSULATION 358" METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING, WHERE APPLICABLE W1 W2 WALL WITH INSULATION 358 " METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING W3 PARTIAL HEIGHT WALL 358 " METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; FIBERGLASS SOUND BATT INSULATION INSIDE WALL; EXTEND WALL TO 9'-6" AFF; PROVIDE 1" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED W4 WALL TYPES W1 NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. DESCRIPTIONDATE ISSUE 07.07.21 REVIEW SET 07.12.21 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR REALYNCSUITE 250350 VETERANS WAY, CARMEL, IN 46032ASAS 2021.077 2ND FLOOR N0 2' 4' 8' 16' 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. GENERAL NOTES NOT TO SCALE WALL AT MULLION DETAIL A111 1 W? AREA NOT IN CONTRACT AREA OF WORK EXISTING WALL CONTRACTOR TO PROVIDE ONE LAYER OF 58" TYPE "X" GYPSUM BOARD ON TENANT SIDE OF EXISTING WALL W2 W2W4 W4 W4 W4 W3 W3 W2 W2 W2 W2 W2 W2 W4 W4 W4 W4 TYP. A111 1 A111 2 0 4' 8' 16' ENLARGED PLAN A111 2 A211 2,3 A211 4 W4 W4 W2 W4 08/13/21