HomeMy WebLinkAboutA111 Architectural PlanWALL
THICKNESS
PRE-FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
LINE OF EXISTING WINDOW
SILL COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
METAL STUD
EXISTING WINDOW
MULLION
EQUAL
OFFICE
205
OFFICE
213
OFFICE
206
OFFICE
207
MEET
212
ENTRY /
COLLABORATION
201 STORAGE
202
CONFERENCE
203
CAFE
209
STG.
214
COLLAB/
FOCUS
208
OPEN OFFICE
210
PHONE RM.
204
PHONE RM.
211 9'-014"10'-5"10'-5" 10'-5" 5'-0"CLEAR9'-11"6'-10" 7'-71
2"
CLEAR
3'-5"10'-5" 10'-5" 11'-0" 4'-5" 12'-0" 12'-0"7'-1" 12'-1112"2'-11" FE6'-034"12
0
°DW2'-51
2" 6'-111
2" 3'-111
4"150°8"2'-812"ARCHITECTURAL
FLOOR PLAN
A111
ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS
ARE IN LINE WITH EXISTING WALLS.
EXISTING COLUMN TO REMAIN EXPOSED. CLEAN AS NECESSARY
AND PREP FOR PAINT; SEE FINISH PLAN FOR MORE INFORMATION.
NEW BRUSHED ALUMINUM RECESSED CABINET AND FIRE
EXTINGUISHER TO BE PROVIDED AND INSTALLED BY CONTRACTOR.
ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO
NFPA 10.
PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR
TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT
LOCATION WITH TENANT.
WRAP EXISTING COLUMN AS TIGHTLY AS POSSIBLE.
IN AREA WITH EXPOSED CEILING DECK, PROVIDE DRYWALL
ALONG EXTERIOR WALL, EXTENDING TO DECK. TRANSITION TO BE
A CLEAN HORIZONTAL LINE FINISHED SUCH THAT CONTRASTING
PAINT COLORS CAN EASILY AND CLEANLY CUT AT WALL TO
CEILING LINE. SEE REFLECTED CEILING PLAN FOR EXACT AREA OF
EXPOSED CEILING.
PROVIDE 8'-0"H WINDOW WITH TIMELY FRAME TO MATCH DOOR
FRAMES, FULL WIDTH OF WALL WITH 38" TEMPERED GLASS.
_______________________________________________________________
PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE
AND VENT PIPING FOR SINKS. WATER HEATER TO BE LOCATED
UNDER COUNTER WITH DRAIN PAN; CONTRACTOR TO INSTALL
AUTOMATIC SHUTOFF VALVES.
PROVIDE WATER LINE FOR REFRIGERATOR. CONFIRM LOCATION
WITH TENANT.
PROVIDE ALL NECESSARY PLUMBING AND DRAINS FOR TENANT'S
DISHWASHER AT THIS LOCATION.
PLAN NOTES
ARCHITECTURAL PLAN
WALL
DOOR AND FRAME
(SEE DOOR SCHEDULE)
NEW CONSTRUCTION EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHTWINDOW / SIDELIGHT
ARCHITECTURAL LEGEND
PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL
WALL TO DECK WITH INSULATION
358" METAL STUDS AT 16" O.C.;
ONE LAYER OF 58" TYPE "X" GYPSUM BOARD
EACH SIDE; EXTEND WALL TO UNDERSIDE OF
DECK; FIBERGLASS SOUND BATT INSULATION
INSIDE WALL AND 2'-0" EACH SIDE OF WALL
ABOVE CEILING, WHERE APPLICABLE
W1
W2
WALL WITH INSULATION
358 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 58" TYPE "X" GYPSUM BOARD
EACH SIDE; EXTEND WALL TO UNDERSIDE OF
CEILING; FIBERGLASS SOUND BATT
INSULATION INSIDE WALL AND 2'-0" EACH
SIDE OF WALL ABOVE CEILING
W3 PARTIAL HEIGHT WALL
358 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 58" TYPE "X" GYPSUM BOARD
EACH SIDE; FIBERGLASS SOUND BATT
INSULATION INSIDE WALL; EXTEND WALL TO
9'-6" AFF; PROVIDE 1" STEEL PIPE ANCHORS
INTO CONCRETE FLOOR FOR SUPPORT AS
REQUIRED
W4
WALL TYPES
W1
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN
RESTROOM AND/OR SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
DESCRIPTIONDATE
ISSUE
07.07.21 REVIEW SET
07.12.21 PERMIT SET
REVISIONS
DESCRIPTIONMARK DATE DB
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER
DRAWN BYPROJ. MGR REALYNCSUITE 250350 VETERANS WAY, CARMEL, IN 46032ASAS
2021.077
2ND FLOOR
N0 2' 4' 8' 16'
1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT.
2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR
WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL
FINISH. REFER TO MANUFACTURER RECOMMENDATIONS.
GENERAL NOTES
NOT TO SCALE
WALL AT MULLION DETAIL
A111
1
W?
AREA NOT IN CONTRACT
AREA OF WORK
EXISTING WALL
CONTRACTOR TO PROVIDE ONE LAYER OF
58" TYPE "X" GYPSUM BOARD ON TENANT SIDE
OF EXISTING WALL
W2
W2W4
W4
W4
W4
W3
W3
W2
W2
W2
W2
W2
W2
W4 W4
W4
W4
TYP.
A111
1
A111
2
0 4' 8' 16'
ENLARGED PLAN
A111
2
A211
2,3
A211
4
W4 W4
W2
W4
08/13/21