HomeMy WebLinkAboutA121 Reflected Ceiling PlanSNSNSNSNSNSNDSNSNSNSN4SN4SN4ELNELN ELNELNSN10'-0"
10'-0"
10'-0"
10'-0" 10'-0"
9'-0"
9'-0"
9'-0"
9'-0"
10'-0"
9'-0"
REFLECTED
CEILING PLAN
A121
CONTROL ENTRY/COLLABORATION 201, CAFE 209 AND OPEN
OFFICE 210 LIGHTING WITH 4-WAY SWITCH AT THIS LOCATION.
PROVIDE MULTIPLE SWITCHES AS REQUIRED.
IN AREA TO REMAIN EXPOSED TO DECK, CLEAN ALL EXPOSED
SURFACES AND PREPARE FOR DRYFALL PAINT (PT5) AS NOTED ON
PLAN PER MANUFACTURER'S RECOMMENDATIONS. PAINT
EXISTING EXPOSED CEILING DECK, EXPOSED DUCTWORK,
SPRINKLER PIPING, JUNCTION BOXES, CONDUIT, STRUCTURAL
BEAMS AND FIREPROOFING IN ACCORDANCE WITH NFPA 13 6.3.8.
PROVIDE RIGID SPIRAL DUCT AND RECTANGULAR SUPPLY
DIFFUSERS AS REQUIRED IN THIS AREA.
TRANSITION FROM CEILING GRID TO EXPOSED CEILING TO BE A 5"
WIDE DRYWALL BULKHEAD EXTENDING FROM 8'-11" AFF TO DECK.
TRANSITION TO BE A CLEAN VERTICAL BULKHEAD, FINISHED SUCH
THAT CONTRASTING PAINT COLORS CAN EASILY AND CLEANLY
CUT AT WALL TO CEILING LINE. VERTICAL FACE OF DRYWALL TO BE
PAINTED COLOR OF ADJACENT WALL. EDGE OF BULKHEAD TO
ALIGN WITH CORNER OF WALL AS SHOWN.
PROVIDE DRYWALL BULKHEAD AT 8'-0" AFF AT THIS LOCATION.
ALIGN EDGES WITH CORNERS OF WALLS AS SHOWN. ALL FACES
OF BULKHEAD TO BE PAINTED (PT_).
PLAN NOTES
LIGHT CIRCUIT
LIGHT SWITCH, DIMMER
LIGHT SWITCH, 3-WAY
LIGHT SWITCH
ND
N
N3
BUILDING STANDARD EXIT LIGHT FIXTURE
RECESSED LIGHT
FIXTURE
LIGHT FIXTURE, 2'x2', LED
METALUX CRUZ
RELOCATED DIFFUSER,
LAY-IN, 4"x4'
RELOCATED DIFFUSER,
LAY-IN, 1'x4'
RELOCATED DIFFUSER,
LAY-IN, 2'x2'
CEILING GRID,
SUSPENDED, 2'x2'
NEW OR RELOCATED
LINEAR SUSPENDED LED: FOCAL POINT, VERVE IV, FL40,
3500K, FINISH: MATTE SATIN WHITE, LENGTHS VARY (SEE
PLAN); BOTTOM OF FIXTURES MOUNTED AT 9'-0" AFF
TRACK LIGHT: CONTECH LIGHTING TL1 SERIES,
COLOR: WHITE
TRACK HEADS: CTL905 SERIES, COLOR: WHITE
(ACTUAL NUMBER OF TRACK HEADS TBD;
COORDINATE WITH SPECIFIED LIGHTING)
TRACK MOUNTED AT 9'-0" AFF
GYPSUM BOARD CEILING
LEGEND
REFLECTED CEILING PLAN
DESCRIPTIONDATE
ISSUE
07.07.21 REVIEW SET
07.12.21 PERMIT SET
REVISIONS
DESCRIPTIONMARK DATE DB
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER
DRAWN BYPROJ. MGR REALYNCSUITE 250350 VETERANS WAY, CARMEL, IN 46032ASAS
2021.077
2ND FLOOR
N0 2' 4' 8' 16'
BUILDING STANDARD EMERGENCY LIGHT FIXTURE
MECHANICAL DIFFUSER RELOCATION
A121
1
*REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
EXISTING VAV BOXES OR
HEAT PUMP AND MAIN SUPPLY
DUCTS TO REMAIN
RELOCATE DIFFUSERS &
FLEXDUCT IF REQUIRED
VAV /
HEAT PUMP
EXHAUST FAN, 2'x2'
EXPOSED TO DECK
A121
1SWITCH, EXHAUST FANNE
1. WHERE NEW CEILING GRID IS SHOWN, PROVIDE BUILDING STANDARD
2X2 GRID AND TILE AT HEIGHT SHOWN ON PLAN.
2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN
SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI
OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT
IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS.
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT
INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1,
CONTRACTOR MUST NOTIFY SDI. OVER 50% OF THE LIGHTING WILL BE
REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL
NEED TO BE MET.
4. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS, PROVIDE COMBO
UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A
ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE
LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF
INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED
OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED.
5. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE.
WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE
MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON
PLAN.
6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO
ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND
LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING
ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS
TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED
SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
ALL APPLICABLE CODES.
GENERAL NOTES
1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL
APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL
MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR
EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO
NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO
THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE
INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES.
MECHANICAL NOTES
AREA NOT IN CONTRACT
AREA OF WORK
20'-0"
20'-0"
20'-0" 20'-0"
20'-0"
20'-0"
12'-0"
8'-0"
8'-0"
A
A
B
A
CERNO, GAVIOTA PENDANT
DIAMETER: 4-0"
SUSPENSION: ANGLED CABLE
RING WALLS: 001 WALNUT
SEAM PLATE: 049 TEXTURED BLACK POWDER COAT
LIGHT DIRECTION: DIRECT
LAMP: 3500K LED
BOTTOM OF FIXTURE MOUNTED AT 7'-0" AFF
B
CERNO, PURA PENDANT
DIAMETER: 30"
WOOD BODY: WALNUT (CM-001)
SHADE: FROSTED POLYMER (CM-051)
LAMP: 3500K LED
FIXTURE MOUNTING HEIGHT TO BE
DETERMINED IN FIELD
08/13/21