Loading...
HomeMy WebLinkAbout15_G1.01-SITE LAYOUT PLAN -NORTH PARKING LOTTBM#3 = 775.53 ADJOINER CONSULTANT CARMEL CLAY SCHOOLS WWW.FHAI.COM ARCHITECT 317-848-0966 COPYRIGHT 2021 BY FANNING/HOWEY ASSOCIATES, INC. CARMEL HIGH SCHOOL 5201 E MAIN STREET CARMEL, IN 46033 HARTMAN FIELD IMPROVEMENTS DESIGN DEVELOPMENT REV. NO. DESCRIPTION DATE PROJECT NUMBER: 220127.00 PROJECT ISSUE DATE: 02/17/2021 DRAWN BY: EB PROJECT 220127.00 350 E NEW YORK ST# 300, INDIANAPOLIS, IN 46204 WWW.TLF-ENGINEERS.COM317-334-1500 3901 W 86TH ST #200, INDIANAPOLIS, IN 46268 W IL L I AME.PAY N EREGISTERE D IND I A N AARCHITE CT 4169 STATE OF No. G1.01 SITE LAYOUT PLAN - NORTH PARKING LOT SEE ENLARGED PLAN G1.02 - SITE LAYOUT PLAN - BASEBALL COMPLEX INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what'sbelow. before you dig.Call R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! SITE KEYNOTES (DOTTEDHATCH)HEAVYDUTYASPHALTPAVEMENTWITHPETROMATENVIRO PAVINGFABRIC- INSTALLPERMANUF.GUIDANCEANDRECOMMENDATIONS, SEEDETAIL#13SHTG4.0 STANDARDCONCRETECURBING/RETAININGCURBWALL;VARIESIN HEIGHT, SEECIVILDRAWINGSANDDETAIL#14SHTG4.OFORFURTHERINFORMATION (HONEYCOMBHATCH)4"CONCRETEWALK,SEEDETAILS#3, #7&#9SHTG4.0 MONOLITHICCURBANDWALK,SEEDETAIL#1SHTG4.0 ADAACCESSIBLECURBRAMPTYPE "A",SEEDETAIL#12SHTG4.0 (NEW )WALKTO EXISTINGWALK,SEEDETAILS#2&#8SHTG4.0 EXISTING ACCESSIBLE RAMP TO REMAIN , PROTECT DURING CONSTRUCTION EXISTING ASPHALT PAVING TO REMAIN , PROTECT DURING CONSTRUCTION EXISTING LAWN; SEE L1.0 FOR FURTHER INFORMATION CURB TAPER, SEE DETAIL #17 SHT. G4.0 EXISTING VARSITY SCOREBOARD; SEE ARCHITECTURAL DRAWINGS FOR FURTHER INFORMATION SEE DETAIL #15 & #16 SHT. G4.0 (NEW) STOP SIGNS (2) (NEW) 8' ORNAMENTAL FENCING, SEE ARCHITECTURAL DRAWINGS AND DETAIL #11 SHT G4.0 FOR FURTHER INFORMATION 1' WIDE x12'+/- LONG WHITE PAINTED STOP BAR 4" WIDE WHITE PAINTED LINE, TYP AT CAR 9X20 +/- PARKING SPACES AND ADA PARKING SPACES CJ -TYPICAL CONTRACTION JOINS, SEE DETAILS #6 & #7 SHT G4.0 EJ - TYPICAL EXPANSION JOINTS, SEE DETAILS #6 & #7 SHT G4.0 ACCESSIBLE CROSSWALK: 4" BLUE PAINTED DIAGONAL LINES, SEE DETAIL #10 SHT G4.O (NEW) MASONRY COLUMN ENTRY AND FENCING, SEE ARCHITECTURAL DRAWINGS FOR FURTHER INFORMATION EXISTING FENCING TO REMAIN, PROTECT DURING THE START OF CONSTRUCTION, SEE G1.03 FOR FURTHER INFORMATION NEW 8' CHAIN LINK FENCING WITH YELLOW PLASTIC FENCE CAP TO MATCH EX. TYP, SEE DETAILS #4, #6, & #7 SHT G4.01 AND PROJECT MANUAL FOR FUTHER INFORMATION NEW 8' HIGH DOUBLE FENCE GATE TO MATCH EXISTING, SEE DETAIL #4 SHT G4.02 NEW 5'-7" HIGH MACRO BOX SLIDE GATE; COLOR (BLACK), 50' MAX OPENING, BY PRO ACCESS SYSTEMS WITH HARDWARE AND ACCESSORIES PER MANUF. WRITTEN RECOMMENDATIONS. PROVIDE A SLIDE DRIVE 40 WITH HYDRAULIC GATE OPERATOR - 1 HP, OPERATING AT ONE FOOT PER SECOND. BATTERY BACKUP TO BE PROVIDED. GATE OPERATOR TO FUNCTION WITH AN OPEN, STOP, CLOSE BUTTON - THE BUTTON IS TO BE LOCATED ON THE INSIDE OF THE COMPLEX FENCING. SAFETY FEATURES TO COMPLY WITH UL-325 PHOTO EYES, AND MILLER EDGES, AS WELL AS LOOP DETECTORS IMBEDDED WITHIN PROPOSED CONCRETE PAVEMENT. GATE IS TO BE LOCKABLE FROM THE INSIDE OF COMPLEX FENCING. SEE DETIAL #5B SHT. G4.02 FOR GATE NEW 8' HIGH SINGLE FENCE GATE TO MATCH EXISTING, SEE DETAIL #4 SHT G4.02 NEW 5' HIGH FENCING WITH YELLOW PLASTIC FENCE CAP TO MATCH EXISTING, SEE DETAILS #4, #6 & #7 SHT G4.01 AND PROJECT MANUAL FOR FURTHER INFORMATION NEW 5' HIGH DOUBLE FENCE GATE TO MATCH EXISTING, SEE DETAIL #4 SHT G4.02 EXISTING STADIUM LIGHTING; SEE ELECTRICAL DRAWINGS FOR FURTHER INFORMATION EXISTING FOUL LINE POLES; (1) LEFT FIELD FOUL POLE TO BE CLEANED, REPAINTED . RIGHT FIELD FOUL POLE IS TO BE DEMOLISHED AND DISPOSED OF LEGALLY OFF SITE - INSTALL NEW RIGHT FIELD FOUL POLE PER DETAIL #3 G4.02 (NEW) JV BACKSTOP FENCING; 25' CHAINLINK FENCING ATTACHED TO EXISTING BACKSTOP FENCING, SEE DETAIL #6 & #7 SHT G4.01 (NEW) TENSION NETTING SYSTEM AND ACCESSORIES; 40' HIGH x 80' LONG NETTING. TENSION NETTING SYSTEM FOUNDATIONS ARE TO BE CONSTRUCTED AND INSTALLED PER MANUFACTURES RECOMMENDATIONS. HEAVY DUTY PAVEMENT AT EXISTING PAVING, SEE DETAIL #18 SHT G4.0 RELOCATED EX. CONCRETE JERSEY BARRIER STOCKPILE PITS (9+/-). (2) CANTILEVER BATTING TUNNELS; STANDARD BLACK POWDER COATED FINISH - 75' LENGTH - END BAY WIDTH 20'-11" - MIDDLE BAY WIDTH @ 18'-9" - INSTALL PER MANUF. GUIDANCE AND RECONMONDATIONS. BATTING CAGE FOUNDATIONS ARE TO BE CONSTRUCTED AND INSTALLED PER MANUF. RECOMMENDATIONS. EXISTING CONCRETE PADS TO REMAIN- CLEAN AND REPAIR AS NEEDED, PROTECT EXISTING CONCRETE PADS DURING THE START OF CONSTRUCTION, SEE DETAIL #6 SHT G4.02 (CONCRETE HATCH) 6" CONCRETE WALK, SEE DETAILS #4 , #7 SHT G4.0 PARKING BUMPERS: PROVIDE PRECAST CONCRETE PARKING BUMPERS - 6' IN LENGTH IN SPECIFIED ( YELLOW ) AND ( HANDICAPPED BLUE ) IN QUANTITIES AND WITHIN SPECIFIED LOCATIONS AS NOTED ON DRAWINGS. EACH PARKING BUMPER IS TO BE INSTALLED ON AT-GRADE OF ASPHALT PAVEMENT - AND SHOULD BE MANUFACTURED WITH TWO HOLES TO ACCOMMODATE THE INSTALLATION OF REBAR, SEE PROJECT MANUAL FOR FURTHER INFORMATION. TYPICAL CONCRETE STOOP: SEE STRUCTURAL DRAWINGS FOR FURTHER INFORMATION ( 6 TOTAL ) SIX SPACE BIKE RACKS SHALL BE ORIGINAL APEX "INVERTED U" BIKE PARKING WITH EMBEDMENT TYPE INSTALLATION AS MANUF. BY SITESCAPES 402-421-9479 IN COLOR AND FINISH AS SELECTED BY ARCHITECT ( BLACK ) TYP, SEE DETAIL #19 SHT. G4.0 NEW 7'-7" TALL , 46' MAX OPENING, MACRO BOX SLIDE GATE BY PRO ACCESS SYSTEMS WITH HARDWARE AND ACCESSORIES PER MANUF. WRITTEN RECOMMENDATIONS, COLOR IS TO MATCH EXISTING FENCING ( BLACK ). PROVIDE A SLIDE DRIVE 40 WITH HYDRAULIC GATE OPERATOR - 1 HP, OPERATING AT ONE FOOT PER SECOND. BATTERY BACKUP TO BE PROVIDED. GATE OPERATOR TO FUNCTION WITH AN OPEN, STOP, CLOSE BUTTON - THE BUTTON IS TO BE LOCATED ON THE INSIDE OF THE COMPLEX FENCING. SAFETY FEATURES TO COMPLY WITH UL-325 PHOTO EYES, AND MILLER EDGES, AS WELL AS LOOP DETECTORS IMBEDDED WITHIN PROPOSED CONCRETE PAVEMENT. GATE IS TO BE LOCKABLE FROM THE INSIDE OF COMPLEX FENCING. SEE DETIAL #5A SHT. G4.02 FOR GATE NEW KNOX LOCK BOXES (3 TOTAL); PROVIDE ( 1 ) KNOX LOCK BOX AT SPECIFIED GATE LOCATION SEE SU1.02 FOR SANITARY CONNECTION EXISTING CONCRETE PAVING TO REMAIN, PROTECT DURING CONSTRUCTION EXISTING FENCING TO REMAIN, PROTECT DURING CONSTRUCTION PROPOSED SITE LEGEND HEAVY DUTY ASPHALT PAVEMENT 6" CONCRETE SIDEWALK / PAD 4" MONOLITHIC WALK AND CURB 4" CONCRETE SIDEWALK PARKING SUMMARY 1. SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND. 2. TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE PROVIDED BY CIVIL ENVIRONMENTAL CONSULTANTS, INC. THE ENGINEER MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECT AREA INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND DEPTH PRIOR TO ANY OTHER SITE CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER. GENERAL NOTES 30 900 30 60 VICINITY MAP 08/19/21