Loading...
HomeMy WebLinkAbout19_G2.0-OVERALL GRADING PLANTBM#2 = 791.71 TBM#3 = 775.53 ADJOINER TBM#1 = 782.26 ADJOINER ADJOINER ADJOINER TBM#4 = 779.85 TBM#2 = 781.44 E. MAI N STREET 1 2 WTR SAN WTR WTR SAN SANWTR SAN SAN SANWT RST-108 ST-102 ST-104 ST-103 ST-107 ST-112 ST-105 ST-113 ST-109 ST-111 ST-101 ST-110 ST-106 ST-114 ST-108A CONSTRUCTION LIMITS CONSTRUCTION LIMITS CONSTRUCTION LIMITS CONSTRUCTION LIMITS CONSTRUCTION LIMITS CONSTRUCTION LIMITS BUILDING INFORMATION FINISH FLOOR ELEV.= 779.75 MIN. LOWEST ADJACENT GRADE = 779.25 MIN. FLOOD PROTECTION GRADE = 778.52 EAST BASIN PROPOSED CONDITIONS CONTRIBUTING DRAINAGE AREA = 13.83 10 YR. DISCHARGE = 10.72 CFS 10 YR. STAGE ELEV.= 774.85 10 YR. STORAGE VOLUME = 0.77 AC/FT 100 YR. DISCHARGE = 12.14 CFS 100 YR. STAGE ELEV.= 776.52 100 YR. STORAGE VOLUME REQUIRED = 2.30 AC/FT 100 YR. STORAGE VOLUME PROVIDED = 6.0 AC/FT UNDERGROUND DETENTION CHAMBERS (SC-740) CONTRIBUTING DRAINAGE AREA = 3.16 ACRES MINIMUM FINISH GRADE ELEV. = 783.00 TOP OF STONE = 782.50 TOP OF CHAMBERS = 781.50 BOTTOM OF CHAMBERS = 779.00 BOTTOM OF STONE = 778.50 21 ROWS OF 27 CHAMBERS = 47,355 CFT. 10 YR. DISCHARGE = 1.02 CFS 10 YR. STAGE ELEV.= 780.06 10 YR. STORAGE VOLUME = 0.49 AC/FT 100 YR. DISCHARGE = 2.03 CFS 100 YR. STAGE ELEV.= 781.20 100 YR. STORAGE VOLUME REQUIRED = 0.85 AC/FT 100 YR. STORAGE VOLUME PROVIDED = 1.09 AC/FT WEST BASIN PROPOSED CONDITIONS CONTRIBUTING DRAINAGE AREA = 17.29 10 YR. DISCHARGE = 7.08 CFS 10 YR. STAGE ELEV.= 777.13 10 YR. STORAGE VOLUME = 0.83 AC/FT 100 YR. DISCHARGE = 7.49 CFS 100 YR. STAGE ELEV.= 779.14 100 YR. STORAGE VOLUME REQUIRED = 3.07 AC/FT 100 YR. STORAGE VOLUME PROVIDED = 3.07 AC/FT 2 2 3 3 3 3 3 2 ST-202ST-201 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 EXIST. STORAGE BUILDING (WEST SIDE) FINISH FLOOR ELEV.= 782.20 PROPOSED RESTROOM BUILDING (EAST SIDE) FINISH FLOOR ELEV.= 780.87 4 OVERTOPPING FLOOD ELEVATION: 780.50± OVERTOPPING FLOOD ELEVATION: 782.50± OVERTOPPING FLOOD ELEVATION: 778.50± OVERTOPPING FLOOD ELEVATION: 781.10± CARMEL SCHOOL ARM OF THE UG MITCHNER DRAIN 30.0' 30.0' 30' REGULATED DRAINAGE EASEMENT BENCHMARKS: 60 1800 60 120 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what'sbelow. before you dig.Call R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! G2.0 OVERALL GRADING PLAN 1. SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND. 2. TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE PROVIDED BY CIVIL ENVIRONMENTAL CONSULTANTS, INC. THE ENGINEER MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECT AREA INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND DEPTH PRIOR TO ANY OTHER SITE CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER. 4. THE MINIMUM FLOOD PROTECTION GRADE OF ALL STRUCTURES FRONTING A POND OR OPEN DITCH SHALL BE NO LESS THAN 2 FEET ABOVE ANY ADJACENT 100-YR LOCAL OR REGIONAL FLOOD ELEVATIONS, WHICHEVER IS GREATER, FOR ALL WINDOWS, DOORS, PIPE ENTRANCES, WINDOW WELLS, AND ANY OTHER STRUCTURE MEMBER WHERE FLOODWATERS CAN ENTER A BUILDING. GENERAL NOTES CONSULTANT Carmel Clay Schools WWW.FHAI.COM ARCHITECT 317-848-0966 350 E NEW YORK ST# 300, INDIANAPOLIS, IN 46204 COPYRIGHT 2021 BY FANNING/HOWEY ASSOCIATES, INC. 5201 East Main Street Carmel, Indiana 46033 CARMEL HARTMAN FIELD IMPROVEMENTSNOT FOR CONSTRUCTIONConstruction Documents REV. NO. DESCRIPTION DATE TAC SUBMITTAL 02/17/2021A PROJECT NUMBER: 220127.00 PROJECT ISSUE DATE: March 1, 2021 DRAWN BY: HHW WWW.TLF-ENGINEERS.COM317-334-1500 3901 W 86TH ST #200, INDIANAPOLIS, IN 46268 GRADING PLAN LEGEND EXISTING SPOT ELEVATION MATCH EXISTING GRADE TOP OF CURB BOTTOM OF CURB EDGE OF PAVEMENT FLOWLINE EXISTING CONTOUR W/ ELEVATION PROPOSED CONTOUR W/ ELEVATION PROPOSED SPOT ELEVATION PROPOSED SURFACE DRAINAGE FLOW ARROW FLOOD ROUTING PATH 100-YEAR OVERFLOW PATHS/PONDING AREAS MEG TC BC EP 750.65 FL USGS BENCHMARK INFORMATION GRADING KEYNOTES 1. CONTRACTOR TO COORDINATE WITH OWNERS REPRESENTATIVE ON LOW SPOT REGRADING. FINAL AREAS TO BE DETERMINED PRIOR TO CONSTRUCTION. SOD TO BE STRIPPED PRIOR TO GRADING ACTIVITY. 2. PROPOSED SWALE @ 1.0% MIN. SLOPE 3. BOTTOM OF DRY BASIN @ 1.0% MIN. SLOPE 4. FLOOD ROUTING PATH FROM THE PROJECT SITE WHEN THE 100 YEAR FLOOD IS EXCEEDED. 08/19/21