HomeMy WebLinkAbout31_SU1.0-OVERALL SITE UTILITY PLANTBM#2 = 791.71 TBM#3 = 775.53 TBM#1 = 782.26 WTR SAN WTR WTR SAN SANWTR SANSAN SANWTRST-106 ST-110 ST-111 ST-114 ST-113 ST-112 ST-109 ST-107 ST-105 ST-104 ST-102 ST-103 ST-108 ST-108A UNDERGROUND DETENTION CHAMBERS ST-101ST-202ST-201 STORM STRUCTURE TABLE STR. NO. 101 102 103 104 105 106 107 108A 108 109 110 111 112 113 114 201 202 STRUCTURE ??? Type "C" Manhole Inlet Type "A" Inlet Type "E" Type "C" Manhole Inlet Type "E" Type "C" Manhole Type "C" Manhole Type "C" Manhole Type "C" Manhole ??? Inlet Type "E" Type "C" Manhole Type "C" Manhole ??? ??? ??? CASTING TYPE ??? R-1772 R-4342 R-4215-C R-1772 R-4215-C R-4342 R-1772 R-1772 R-4342 ??? R-4215-C R-1772 R-1772 ??? ??? ??? RIM 779.30 781.90 780.05 778.96 780.00 778.90 780.89 783.00 784.24 780.80 778.89 778.56 780.44 780.17 777.33 783.03 782.30 INCOMING PIPE DATA (DIRECTION) [FROM STR] 15" HDPE Pipe 776.96 (S) [101] 15" HDPE Pipe 776.77 (W) [102] 12" HDPE Pipe 776.77 (S) [103] 18" HDPE Pipe 776.25 (S) [104] 12" HDPE Pipe 776.52 (N) [106] 12" HDPE Pipe 778.40 (S) [108A] 12" HDPE Pipe 776.14 (W) [107] 15" HDPE Pipe 777.99 (SW) [108] 12" HDPE Pipe 776.76 (E) [110] 18" HDPE Pipe 775.91 (S) [105] 15" HDPE Pipe 775.91 (W) [109] 12" HDPE Pipe 775.91 (N) [111] 24" HDPE Pipe 775.23 (W) [112] 24" HDPE Pipe 775.00 (W) [113] 12" HDPE Pipe 781.17 (W) [201] OUTGOING PIPE DATA (DIRECTION) [TO STR] 15" HDPE Pipe 777.83 (N) [102] 15" HDPE Pipe 776.86 (E) [104] 12" HDPE Pipe 777.10 (N) [104] 18" HDPE Pipe 776.67 (N) [105] 18" HDPE Pipe 776.15 (N) [112] 12" HDPE Pipe 776.69 (S) [107] 12" HDPE Pipe 776.42 (E) [109] 12" HDPE Pipe 778.50 (N) [108] 15" HDPE Pipe 778.40 (NE) [109] 15" HDPE Pipe 776.04 (E) [112] 12" HDPE Pipe 777.76 (W) [111] 12" HDPE Pipe 776.66 (S) [112] 24" HDPE Pipe 775.81 (E) [113] 24" HDPE Pipe 775.13 (E) [114] 12" HDPE Pipe 781.90 (E) [202] OUTGOING PIPE L.F. 290' 29' 108' 143' 80' 57' 93' 18' 136' 46' 32' 65' 193' 42' 44' OUTGOING PIPE SIZE 15" HDPE Pipe 15" HDPE Pipe 12" HDPE Pipe 18" HDPE Pipe 18" HDPE Pipe 12" HDPE Pipe 12" HDPE Pipe 12" HDPE Pipe 15" HDPE Pipe 15" HDPE Pipe 12" HDPE Pipe 12" HDPE Pipe 24" HDPE Pipe 24" HDPE Pipe 12" HDPE Pipe OUTGOING GRADE 0.30% 0.30% 0.30% 0.30% 0.30% 0.30% 0.30% 0.57% 0.30% 0.30% 3.13% 1.16% 0.30% 0.30% 1.65% CONNECT TO STR. 102 104 104 105 112 107 109 108 109 112 111 112 113 114 202 REMARKS End Section - - End Section - - Aquaswirl XC-7 Per Manufacturer End Section - - ACO Trench Drain Per Manufacturer End Section - End Section - - - ALL STORM SEWER CASTINGS SHALL BE MARKED "DUMP NO WASTE DRAINS TO WATERWAYS" ARCHITECT Carmel Clay Schools CONSULTANT Construction Documents WWW.FHAI.COM317-848-0966 350 E NEW YORK ST# 300, INDIANAPOLIS, IN 46204 COPYRIGHT 2021 BY FANNING/HOWEY ASSOCIATES, INC. 5201 East Main Street Carmel, Indiana 46033 CARMEL HARTMAN FIELD IMPROVEMENTS PROJECT NUMBER: 220127.00 PROJECT ISSUE DATE: May 12, 2021 DRAWN BY: HHW WWW.TLF-ENGINEERS.COM317-334-1500 3901 W 86TH ST #200, INDIANAPOLIS, IN 46268 REV. NO. DESCRIPTION DATE SU1.0 OVERALL SITE UTILITY PLAN THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS, OR 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL. STORM SEWER NOTE UTILITY PLAN LEGEND PROPOSED 2" PVC WATER LINE PROPOSED 8" PVC SANITARY SEWER PIPE WTR SAN 60 1800 60 120 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what'sbelow. before you dig.Call R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! 1. SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND. 2. TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE PROVIDED BY CIVIL ENVIRONMENTAL CONSULTANTS, INC. THE ENGINEER MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECT AREA INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND DEPTH PRIOR TO ANY OTHER SITE CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER. 4. SEE SHEET G2.1 FOR GRADING PLAN. 5. THE PROPOSED STORM SEWER SYSTEM FOR THIS PROJECT WILL BE PRIVATE OWNED. 6. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 7. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPERS RESPONSIBILITY TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. 8. DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. 9. IT IS THE CONTRACTORS RESPONSIBILITY TO REMOVE OR RELOCATE ANY EXISTING UTILITY LINES WHICH INTERFERE WITH NEW STORM SEWER INSTALLATION. GENERAL NOTES 08/19/21