Loading...
HomeMy WebLinkAbout35_SU3.01-SITE UTILITY DETAILSSEE STRUCTURE DATA TABLE FOR CASTING TYPE AND ELEVATION FINISH GRADE ASPHALTIC MASTIC OR BUTYL RUBBER SEAL BETWEEN JOINTS PRECAST CONCRETE ADJUSTING RINGS AS NEEDED (12" OF RINGS MAX.) ECCENTRIC CONE OR REDUCER CAP AS REQUIRED BY SITE CONDITIONS. CONE TOP TO MATCH ADJUSTING RING PROFILE. 48" DIA. 5"16"TYP.PRECAST CONCRETE SECTIONS PREFORMED HOLE TO MAX. OF PIPE O.D. + 6" W/ NON SHRINK CEMENT GROUT BENCHWALLS AT MIN. 1/2" PER FOOT SLOPE. BENCHWALLS TO BE CONSTRUCTED TO SPRING LINE OF PIPE. MANHOLE BASE SET ON 6" OF #8 OR #2 STONECOMPACTED SUBGRADE PLASTIC ENCAPSULATED STEEL MANHOLE STEPS O-RING GASKET ASPHALTIC MASTIC OR BUTYL RUBBER SEAL AT JOINTS BASE 6" OR 8" PER SECTION 3"#4 BAR @ 12" o.c. EACH WAY (STEEL MESH AREA = 0.12 SQ. IN./SQ. FT.) STORM MANHOLE TYPE "C" DETAIL 1/2" = 1'-0" 24" DIA. SEE STRUCTURE DATA TABLE FOR PIPE SIZE AND INVERT ELEV. NOTES: 1. MANHOLE CONFORMS TO ASTM C478, JOINTS CONFORM TO ASTM C443. 2. ALL STORM SEWER CASTINGS SHALL BE MARKED "DUMP NO WASTE DRAINS TO WATERWAYS". 3. SEE UTILITY PLAN FOR STORM SEWER STRUCTURE DATA TABLE.VARIES16" MIN.12" TO 15""A" PIPE SIZE 24" X 24" STRUCTURE SIZING CHART "F" 30" X 30" "M" 24" X 36" 1" = 1'-0" STORM INLET DETAIL INSIDE DIMENSIONS INLET TYPE 8"6" CLASS "A" PRECAST REINFORCED CONCRETE BOX SEE STRUCTURE DATA TABLE FOR PIPE SIZE AND INVERT ELEV. INSIDE DIMENSION * SEE SIZING CHART ABOVE SEE STRUCTURE DATA TABLE FOR CASTING TYPE AND ELEVATION BASE SET ON 6" OF #8 OR #2 STONE COMPACTED SUBGRADEINSIDE DIMENSION* SEE SIZING CHART ABOVEMAX. NUMBER OF SIDES OF THE INLET WITH PIPES 3 18" TO 24" 315" TO 18" 3 NOTES: 1. ALL STORM SEWER CASTINGS SHALL BE MARKED "DUMP NO WASTE DRAINS TO WATERWAYS". 2. SEE UTILITY PLAN FOR STORM SEWER STRUCTURE DATA TABLE. FOR PIPE LOCATED IN AND WITHIN 5' OF PAVED AREAS FOR PIPE LOCATED IN GRASSED AREAS STORM SEWER (PVC & HDPE) TRENCH DETAIL NO SCALE NOTES: 1. ALL BEDDING & INITIAL BACKFILL SHALL BE INSTALLED IN 6" TO 12" BALANCED LIFTS. 2. A MIN. 9" CLEARANCE EACH SIDE OR PIPE FOR 42" DIA. AND LESS. Bc MIN.4"12"MIN. 1.25 O.D.+12" MIN. 6" TOPSOIL OUTSIDE PAVEMENT LIMITS PAVEMENT SECTION REGULAR BACKFILL - GREATER THAN 5' FROM EDGE OF PAVEMENT COMPACTED 90% REGULAR BACKFILL- GREATER THAN 5' FROM EDGE OF PAVEMENT COMPACTED TO 90% #8 CRUSHED STONE OR EQUIVALENT CLASS 1 MATERIAL HAND TAMPED OR WALKED INTO PLACE "B" BORROW (INDOT SPEC.) OR EQUIVALENT GRANULAR MATERIAL COMPACTED TO 95% STANDARD PROCTER DENSITY STORM SEWER / WATER LINE CROSSING DETAIL NONE NO SCALE 1 1/2" RAD.WALLDIAMETER R-1E 1 1/2" RAD. WALL 1/32 TAPER PER INCH PER SIDE WALL R-1 E WALL DIA.+1ADIAMETER HORIZONTAL FLARE VERTICAL FLARE SECTION BB R-2 BSKIRT DIAMETERA B D B C WALLDIAMETER SECTION AA G or T (TONGUE-INLET END)WALL (GROOVE-OUTLET END) A 52249 98 84 26 72 24 6550 4 5 48 28 35 39 21 21 21 21 PORTIONS OF A.S.T.M. SPECIFICATION C76. NOTE: MANUFACTURER OF END SECTION IS IN ACCORDANCE WITH APPLICABLE 78 84 7 8 6 7 6 60 66 72 6 7 54 5 5 5 6 4 14430 16350 24 24 78 78 308750 10630 12520 24 34 8040 27 60 78 78 65 99 99 114 120 79 85 99 99 99 100 6196 102 108 67 73 90 55 44 41 24 24 8 9 2436 38 35 24 24 32 24 6 7 7 6 SIZE SCHEDULE 46 48 38 30 25 19 34 35 39 46 2 3 27 36 42 4 4 30 33 3 3 3 3 3 3 2 21 24 3 15 18 2 2 2 2 2 2 48 10 1930 4100 5380 15 21 2190 3150 12 13 63 63 54 58 9 1280 1520 9 740 990 6 9 35 43 27 27 WALL DIA. 12 2 G or T 1 A WT. SEC 530 4 24 B 28 73 54 97 98 73 97 72 78 37 43 60 66 31 34 73 73 73 73 22 42 48 25 30 36 16 19 41417 27 24 20 22 23 18 15 17 5 5 5 5 1316 16 14 15 12 11 12 4 4 3 4 72 C D DIA.+1E 24 13 R-2R-1 10 9 SKIRT 3 PRECAST FLARED END SECTION DETAIL SLOPE MIN. NOTE: CLEANOUTS IN PAVED AREAS TO BE ACCESSIBLE VIA YARD BOXES OR EXTENDED FLUSH WITH THE PAVING. CO VER SHOULD BE THREADED TYPE, WATER TIGHT AND CAPPED. 1/2" = 1'-0" EXTERIOR CLEANOUT DETAILVARIESFINISH GRADE STORM SEWER (SIZE SHOWN ON PLANS) SAME SIZE AS MAIN LINE (MAX. 8" REQUIRED ON STORM SEWERS) 1'-0" 1'-0" MIN.6"1/2"HEAVY DUTY CLEANOUT CASTING - JAY R. SMITH 4253 SERIES OR EQUAL CONCRETE COLLAR (CONCRETE SHALL NOT BE IN CONTACT w/ PIPE) PRECAST CONCRETE SECTIONS MANHOLE BASE SET ON 6" OF #8 OR #2 STONECOMPACTED SUBGRADE OUTLET CONTROL STR 108 DETAIL NOT TO SCALE 24" DIA. SEE SCHEDULE FOR CASTING TYPE ELEV: 784.24 FINISH GRADE ASPHALTIC MASTIC OR BUTYL RUBBER SEAL BETWEEN JOINTS 8" REDUCER CAP 16"PLASTIC ENCAPSULATED STEEL MANHOLE STEPS O-RING GASKET ASPHALTIC MASTIC OR BUTYL RUBBER SEAL AT JOINTS 12" THICK STEEL PLATE RESTRICTOR 12" HDPE INFLUENT INV. = 778.4012" HDPE OUTLET INV. = 778.40 2' SUMPREQ'D.BASE 6" OR 8" PER SECTION #4 BAR @ 12" o.c. EACH WAY (STEEL MESH AREA = 0.12 SQ. IN./SQ. FT.)12" HDPEINFLUENTPIPE12" HDP E OUTL E T PI PE12" THICK STEEL PLATE RESTRICTOR 1/2" THICK STEEL PLATE ANGLE BRACKET (TYP.) MANHOLE BTM INV. = 776.40 TOP OF PLATE ELEV = 782.41 (100-YR) 6" DIA. CIRCULAR ORIFICE INV. = 778.40 6" CIRCULAR ORIFICE INV. = 780.50 ACO TRENCH DRAIN CHANNEL DETAIL SU3.01 SITE UTILITY DETAILS ARCHITECT Carmel Clay Schools CONSULTANT Construction Documents WWW.FHAI.COM317-848-0966 350 E NEW YORK ST# 300, INDIANAPOLIS, IN 46204 COPYRIGHT 2021 BY FANNING/HOWEY ASSOCIATES, INC. 5201 East Main Street Carmel, Indiana 46033 CARMEL HARTMAN FIELD IMPROVEMENTS PROJECT NUMBER: 220127.00 PROJECT ISSUE DATE: May 12, 2021 DRAWN BY: HHW WWW.TLF-ENGINEERS.COM317-334-1500 3901 W 86TH ST #200, INDIANAPOLIS, IN 46268 REV. NO. DESCRIPTION DATE 08/19/21