Loading...
HomeMy WebLinkAboutIan Gernhardt_07-29-2021_Planset15.2 KWSYSTEM SIZE :20.07 KW DC STCVICINITY MAPSITE MAP (N.T.S)A-00SITE MAP &VICINITY MAP IAN GERNHARDTNEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEMDC SYSTEM SIZE (20.07 KW)32°C-22°C20 PSF106MPHIIB64 A(2) SE7600H-US SOLAREDGE INVERTERLINE SIDE TAP IN THE MSPWIND FLOW MAP(3) BRANCHES OF 14 MODULES(1) BRANCH OF 13 MODULESSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROYY07/29/2021DESIGNERREVIEWERDATEIAN GERNHARDT 498 E 114TH ST, CARMEL, IN 46032, USA Signature with SealADD : 1821 S. BASCOM AVE, UNIT191. CAMPBELL, CA 95008, USALICENSE #1014694CONTACT: 1-855-573-2843ENGG.DC RATING OF SYSTEMAC RATING OF SYSTEMAC OUTPUT CURRENTNO. OF MODULESNO. OF INVERTERSPOINT OF CONNECTIONARRAY STRINGINGDESCRIPTIONNEW GRID-INTERACTIVE PHOTOVOLTAICSYSTEM WITH BATTERY STORAGESYSTEM DETAILSGOVERNING CODESINDIANA RESIDENTIAL CODE (IRC) 2020INDIANA BUILDING CODE (IBC) 2014INDIANA FIRE CODE (IFC) 2014NATIONAL ELECTRIC CODE, NEC 2008 CODE BOOK, NFPA 70SITE MAP & VICINITY MAPA - 00ELECTRICAL LINE DIAGRAMWIRING CALCULATIONSSYSTEM LABELINGMODULE DATASHEETE - 01E - 02E - 03STRUCTURAL ATTACHMENT DETAILINVERTER DATASHEETOPTIMIZER DATASHEETATTACHMENT DATASHEETDS - 01DS - 02DS - 03DS - 04S - 02SHEET INDEXSHEET NO.SHEET NAMEARRAY LAYOUTS - 03RACKING DATASHEETDS - 05SITE DETAILSASHRAE EXTREME LOWASHRAE 2% HIGHGROUND SNOW LOADWIND SPEEDRISK CATEGORYWIND EXPOSURE CATEGORY(55) REC 365 ALPHA (365W) MODULES(55) P370 SOLAREDGE OPTIMIZERSNO. OF OPTIMIZERSROOF PLAN & MODULESS - 01DRIVEWAYMSPUMACDINV (N) SE7600H-USSOLAREDGE INVERTER(N) AC DISCONNECT(E) UTILITY METER(OUTSIDE HOUSE)(E) MAIN SERVICE PANEL(INSIDE HOUSE)18" SETBACK3' SETBACKPV ARRAYROOF 183'-9"121'-4"85'-6"120'-2"48'-8"4'-11"14'-9"ROOF 2ROOF 4ROOF 3E 114TH STINV(N) SE7600H-USSOLAREDGE INVERTERCP(N) COMBINER PANEL S-01 & MODULESROOF PLANMODULE TYPE, DIMENSIONS & WEIGHTSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROYY07/29/2021DESIGNERREVIEWERDATEIAN GERNHARDT 498 E 114TH ST, CARMEL, IN 46032, USA Signature with SealADD : 1821 S. BASCOM AVE, UNIT191. CAMPBELL, CA 95008, USALICENSE #1014694CONTACT: 1-855-573-2843ENGG.I CERTIFY THAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH IBC: RESIDENTIAL CHAPTER 3.BUILDINGSTRUCTURE WILL SAFELY ACCOMMODATE LATERAL AND UPLIFTWIND LOADS, AND EQUIPMENT DEAD LOADS. *GENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS TO TRUSSES SHALL BE INSTALLEDAS SHOWN IN SHEET S-01 AND AS FOLLOWS FOR EACH WINDZONE:.WIND ZONE 1: MAX SPAN 6'-0" O.C.WIND ZONE 2: MAX SPAN 4'-0" O.C.WIND ZONE 3: MAX SPAN 2'-0" O.C.2) EXISTING RESIDENTIAL BUILDING IS AN ASPHALT SHINGLEROOF WITH MEAN ROOF HEIGHT 15 FT AND 2"x4" WOOD ROOFRAFTER SPACED 24" O.C.CONTRACTOR TO FIELD VERIFY AND SHALL REPORT TO THEENGINEER IF ANY DISCREPANCIES EXIST BETWEEN PLANSAND IN FIELD CONDITIONS.LEGENDSUMACDPMMSP- UTILITY METERJB- AC DISCONNECT- PRODUCTION METER- MAIN SERVICE PANEL- VENT, ATTIC FAN (ROOF OBSTRUCTION)- JUNCTION BOXCP- COMBINER PANEL- CONDUIT- OPTIMIZER- FIRE SETBACKNUMBER OF MODULES = 55 MODULESMODULE TYPE = REC 365 ALPHA (365W) MODULESWEIGHT = 43 LBS / 19.5 KG.MODULE DIMENSIONS = 67.8" X 40" = 18.83 SFNUMBER OF OPTIMIZER = 55OPTIMIZER TYPE = P370 SOLAREDGE OPTIMIZERSNUMBER OF INVERTER = 2INVERTER TYPE = SE7600H-US SOLAREDGE INVERTERDC SYSTEM SIZE: 20.07 KWAC SYSTEM SIZE: 15.2 KWINV- INVERTERM- METER MAIN COMBO(E) BACK YARD(E) FRONT YARD18" SETBACK3' SETBACKPV ARRAYROOF 1ROOF 2ROOF 4ROOF 3JBROOF ACCESS POINTROOF ACCESS POINTROOF ACCESS POINTMSPUMACDINV(N) SE7600H-USSOLAREDGE INVERTER(N) AC DISCONNECT(E) UTILITY METER(OUTSIDE HOUSE)(E) MAIN SERVICE PANEL(INSIDE HOUSE)INV(N) SE7600H-USSOLAREDGE INVERTERCP(N) COMBINER PANELCONDUIT RUNJUNCTION BOX S-02ARRAYLAYOUT(ROOF #1)ROOF DESCRIPTION:SHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROYY07/29/2021DESIGNERREVIEWERDATEIAN GERNHARDT 498 E 114TH ST, CARMEL, IN 46032, USA Signature with SealADD : 1821 S. BASCOM AVE, UNIT191. CAMPBELL, CA 95008, USALICENSE #1014694CONTACT: 1-855-573-2843ENGG.MODULES - 8ROOF TILT - 20°ROOF AZIMUTH - 180°TRUSSES SIZE - 2"X6" @ 24" O.C.LEGENDS- VENT, ATTIC FAN (ROOF OBSTRUCTION)- PV ROOF ATTACHMENT- RAFTERS / TRUSSES- COUPLING- FIRE SETBACK- WIND ZONE II- WIND ZONE III- WIND ZONE I(ROOF #3)(ROOF #2)MODULES -8ROOF TILT - 20°ROOF AZIMUTH - 180°TRUSSES SIZE - 2"X6" @ 24" O.C.MODULES -12ROOF TILT - 20°ROOF AZIMUTH - 90°TRUSSES SIZE - 2"X6" @ 24" O.C.(ROOF #4)MODULES -27ROOF TILT - 20°ROOF AZIMUTH - 270°TRUSSES SIZE - 2"X6" @ 24" O.C.SOLAR MODULE21'-11"13'-6"26'-6"20'-11"12'-4"15'-5"50'-10"15'-4"18" SETBACK3' SETBACKROOF #1ROOF #2ROOF #420'-5"15'-2"ROOF #320'-11"30'-5"50'-10" PHOTOVOLTAIC MODULE GENERAL NOTES:1. APPLICABLE CODE: 2020 INDIANO BUILDING CODE 7th ED. & ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER NDS(2012)REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A WOOD ROOF TRUSS AS EMBEDMENT MATERIAL.3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLERESIDENTIAL ROOFS, CONSIDERING FROM A 7° TO A MAXIMUM 27° (2/12 TO AMAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. ALL RESIDENTIAL ROOFS SHALL NOTEXCEED 30'-0" MEAN ROOF HEIGHT.4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511.5. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TOMANUFACTURERS' MANUAL FOR ALL ARCHITECTURAL, MECHANICAL,ELECTRICAL, AND SOLAR SPECS.6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESSOTHERWISE NOTED.7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED.8. ALL RAILING AND MODULES SHALL BE INSTALLED PERMANUFACTURERS' INSTRUCTIONS.9. I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCEWITH IBC:BUILDING CHAPTER 16 AND IRC:RESIDENTIAL CHAPTER 3.BUILDING STRUCTURE WILL SAFELY ACCOMMODATE CALCULATEDWIND LATERAL AND UPLIFT FORCES, AND EQUIPMENT DEAD LOADS.S-03STRUCTURAL ATTACHMENTDETAILSSTRUCTURAL ATTACHMENT DETAILSSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROYY07/29/2021DESIGNERREVIEWERDATEIAN GERNHARDT 498 E 114TH ST, CARMEL, IN 46032, USA Signature with SealADD : 1821 S. BASCOM AVE, UNIT191. CAMPBELL, CA 95008, USALICENSE #1014694CONTACT: 1-855-573-2843ENGG.IRONRIDGE XR100SOLAR MODULE5/16"x4" STAINLESSSTEEL LAG SCREWWOOD SHEATHINGRAFTERSRAFTERSIRONRIDGE XR100WOOD SHEATHINGIRONRIDGE (L MOUNT)IRONRIDGE FLASHFOOT2IRONRIDGE (L MOUNT)IRONRIDGE FLASHFOOT2 NOTE:1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THEREQUIREMENTS OF THE NEC 2008, NFPA 70 AND INCLUDING MAXIMUMNUMBER OF MODULE STRINGS, MAXIMUM NUMBER OF MODULES PERSTRING, MAXIMUM OUTPUT, MODULE MANUFACTURER AND MODELNUMBER, INVERTER MANUFACTURER AND MODEL NUMBER, ASAPPLICABLE.2. PROVIDE TAP BOX IN COMPLIANCE WITH 312.8 IF PANEL GUTTERSPACE IS INADEQUATE.E-01ELECTRICALLINE DIAGRAMSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROYY07/29/2021DESIGNERREVIEWERDATEIAN GERNHARDT 498 E 114TH ST, CARMEL, IN 46032, USA Signature with SealADD : 1821 S. BASCOM AVE, UNIT191. CAMPBELL, CA 95008, USALICENSE #1014694CONTACT: 1-855-573-2843ENGG.SE7600H-US240V32 VSOLAREDGE INVERTERINVERTER SPECIFICATIONMANUFACTURERMODEL NO.MAX.AC OUTPUT VOLTAGE AC OUTPUT CURRENT7600 WMAX.OUTPUT POWERP37011 A15 ASOLAREDGE OPTIMIZEROPTIMIZER SPECIFICATIONMANUFACTURERMODEL NO.SHORT CIRCUIT CURRENT(Isc)MAX. AC OUTPUT CURRENT60VOPEN CIRCUIT VOLTAGE (Voc)ARRAY DETAILSDC SYSTEM SIZEAC SYSTEM SIZETOTAL NO. OF MODULES15.2 KW5520.07 KWNO. OF MODULE PER STRINGNO. OF STRING43@14REC 365 Alpha10.26RECMODULE SPECIFICATIONMANUFACTURERMODEL NO.SHORT CIRCUIT CURRENT(Isc)44.3OPEN CIRCUIT VOLTAGE (Voc)9.6RATED CURRENT (Impp)38RATED VOLTAGE (Vmpp)1@13200AINVERTER 1DC UNGROUNDED80/2PGGNGGUM125A ACDISCONNECTFUSEDMAIN SERVICEPANEL120/240V200AINVERTER 2DC UNGROUNDEDGG125A ACCOMBINERPANELG40A/2P40A/2P80/2PSE7600H-USSOLAREDGE INVERTERSE7600H-USSOLAREDGE INVERTER(4) #10 AWG THWN-2(1) #10 BARE CONDUCTOR GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUN(2) #4 AWG THWN-2(1) #6 BARE CONDUCTOR GNDIN 1" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUN(4) #10 AWG THWN-2(1) #10 BARE CONDUCTOR GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUN(2) #8 AWG THWN-2(1) #10 BARE CONDUCTOR GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUN(2) #8 AWG THWN-2(1) #10 BARE CONDUCTOR GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUN1 STRING OF14 MODULESW/OPTIMIZERS1 STRING OF14 MODULESW/OPTIMIZERS1 STRING OF14 MODULESW/OPTIMIZERS1 STRING OF13 MODULESW/OPTIMIZERS ELECTRICAL NOTES1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, ANDLABELED FOR ITS APPLICATION.2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90DEGREE C WET ENVIRONMENT.THE TERMINALS ARE RATED FOR75 DEGREE C.3. CONDUCTOR TERMINATION AND SPLICING AS PER NEC 110.144. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPSSHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE ASPOSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.5. WORKING CLEARANCES AROUND ALL NEW AND EXISTINGELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.6. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLECODES AND STANDARDS.7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITSARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEMACCORDINGLY.8. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELEDAND READILY VISIBLE.9. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULEFRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIPMANUFACTURER'S INSTRUCTION.10. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPERG.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.11. THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .12. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICEENTRANCE.13. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.14. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.15. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED ASSUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE310.10 (D).16. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLEFOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C).E-02WIRINGCALCULATIONSSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROYY07/29/2021DESIGNERREVIEWERDATEIAN GERNHARDT 498 E 114TH ST, CARMEL, IN 46032, USA Signature with SealADD : 1821 S. BASCOM AVE, UNIT191. CAMPBELL, CA 95008, USALICENSE #1014694CONTACT: 1-855-573-2843ENGG.ELECTRICAL CALCULATIONS:1. BEFORE INVERTER:AMBIENT TEMPERATURE = 32CONDUIT INSTALLED AT MINIMUM DISTANCE OF 7/8 INCHES ABOVE ROOF .....NEC 310.15(B)(3)(c)TEMPERATURE DERATE FACTOR - (0.96) ..............NEC 310.15(B)(2)(a)GROUPING FACTOR - (0.8) .................................NEC 310.15(B)(3)(a)CONDUCTOR AMPACITY=(OPTIMIZER O/P CURRENT ) x 1.25 / A.T.F / G.F ...NEC 690.8(B)=[14 x 1.56] / 0.96 / 0.8=28.43 ASELECTED CONDUCTOR - #10 THWN-2 ...NEC 310.15(B)(16)2. AFTER INVERTER:TEMPERATURE DERATE FACTOR - 0.96GROUPING FACTOR - 1 CONDUCTOR AMPACITY=(TOTAL INV O/P CURRENT) x 1.25 / 0.96 / 1 ...NEC 690.8(B)=[((32+32) x 1.25] / 0.96 / 1]=83.33 A SELECTED CONDUCTOR - #4THWN-2 ...NEC 310.15(B)(16)3. PV OVER CURRENT PROTECTION ...NEC 690.9(B)=TOTAL INVERTER O/P CURRENT x 1.25= (32+32) x 1.25 = 80ASELECTED OCPD = 80 ASELECTED EQUIPMENT GROUNDING CONDUCTOR (EGC) = #10 THWN-2 ...NEC 250.122(A) E-03SHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROYY07/29/2021DESIGNERREVIEWERDATEIAN GERNHARDT 498 E 114TH ST, CARMEL, IN 46032, USA Signature with SealADD : 1821 S. BASCOM AVE, UNIT191. CAMPBELL, CA 95008, USALICENSE #1014694CONTACT: 1-855-573-2843ENGG.SYSTEMLABELINGWARNINGELECTRIC SHOCK HAZARD!DO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTIONPER CODE: NEC 690.17(E), CBPHOTOVOLTAIC SYSTEM AC DISCONNECTRATED OPERATING AC CURRENT 64 AMPSNOMINAL AC OPERATING VOLTAGE 240 VOLTSLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC690.54)WARNINGLABEL LOCATION:CONDUIT, COMBINER BOX(PER CODE: NEC690.31(G)(3)(4) & NEC 690.13(G)(4)LABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(D)(3) & NEC 690.64)ADHESIVE FASTENED SIGNS:· THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENTWHERE IT IS INSTALLED. NEC110.21(B)(3)· WHERE REQUIRED ELSEWHERE IN THIS CODE AND FIELDAPPLIED LABELS, WARNING(S) AND MARKING SHALL COMPLYWITH ANSI Z535.4. NEC 110.21(B) FIELD MARKING· ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLEIF PROPERLY ADHERED. VINYL SIGNS SHALL BEWEATHER RESISTANT. IFC 605.11.1.3INVERTER OUTPUT CONNECTION DO NOTRELOCATE THIS OVERCURRENT DEVICELABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(D)(7))[Not required if panelboard is rated not less than sum of ampere ratingsof all overcurrent devices supplying it]LABEL LOCATION:AC DISCONNECT, DC DISCONNECT, POINT OFINTERCONNECTION(PER CODE: NEC690.56(C))PHOTOVOLTAIC SYSTEMEQUIPPED WITH RAPIDWARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!1-855-573-2843EMERGENCY CONTACTWARNING!INVERTER OUTPUT CONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICEWARNING!DEDICATED SOLAR PANELS DONOT CONNECT ANY OTHER LOADSFigure 690.56(C)(1)(a) Label for PV Systems thatShut down the array and the conductors leaving the arraySHUTDOWNSOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWNWARNING PHOTOVOLTAICPOWER SOURCE DS-01DATASHEETMODULESHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROYY07/29/2021DESIGNERREVIEWERDATEIAN GERNHARDT 498 E 114TH ST, CARMEL, IN 46032, USA Signature with SealADD : 1821 S. BASCOM AVE, UNIT191. CAMPBELL, CA 95008, USALICENSE #1014694CONTACT: 1-855-573-2843ENGG. DS-02DATASHEETOPTIMIZERSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROYY07/29/2021DESIGNERREVIEWERDATEIAN GERNHARDT 498 E 114TH ST, CARMEL, IN 46032, USA Signature with SealADD : 1821 S. BASCOM AVE, UNIT191. CAMPBELL, CA 95008, USALICENSE #1014694CONTACT: 1-855-573-2843ENGG. DS-03DATASHEETINVERTERSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROYY07/29/2021DESIGNERREVIEWERDATEIAN GERNHARDT 498 E 114TH ST, CARMEL, IN 46032, USA Signature with SealADD : 1821 S. BASCOM AVE, UNIT191. CAMPBELL, CA 95008, USALICENSE #1014694CONTACT: 1-855-573-2843ENGG. DS-04DATASHEETATTACHMENTSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROYY07/29/2021DESIGNERREVIEWERDATEIAN GERNHARDT 498 E 114TH ST, CARMEL, IN 46032, USA Signature with SealADD : 1821 S. BASCOM AVE, UNIT191. CAMPBELL, CA 95008, USALICENSE #1014694CONTACT: 1-855-573-2843ENGG. DS-05DATASHEETRACKINGSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROYY07/29/2021DESIGNERREVIEWERDATEIAN GERNHARDT 498 E 114TH ST, CARMEL, IN 46032, USA Signature with SealADD : 1821 S. BASCOM AVE, UNIT191. CAMPBELL, CA 95008, USALICENSE #1014694CONTACT: 1-855-573-2843ENGG.