HomeMy WebLinkAboutNapleton Hyuandi - HVAC and Plumbing Plans - MP100SK
S-2
200
S-2
200
S-3
240
S-3
240
S-3
240
S-3
240
S-1
100
S-1
100
S-1
100
S-1
100
S-1
100
S-3
240
8"Ø
10"Ø 10"Ø
10"Ø
10"Ø10"Ø6"Ø6"Ø6"Ø
6"Ø
6"Ø
20/1418/14 14"Ø 12"Ø12"Ø8"Ø 20/16EXISTING S/A DUCT SERVING
SPACE NOT IN CONTRACT
EXISTING R/ADUCTR-1
R-2
R-1
10"Ø
6"Ø
18"Ø 12"ØIMB
6 8 10 11
J
K
H
J
K
H
6 8 10 11
EXISTING S/A DUCT SERVING
SPACE NOT IN CONTRACT
EXISTING R/A DUCTMP100
HVAC AND
PLUMBING PLANS
DRAWING ISSUE HISTORY
BID / PERMIT ISSUE:
CONSTRUCTION SET:
COPYRIGHT 2021
210519
JP
JP
AS NOTED
PROJECT NO:
DRAWING DATE:
DRAWN BY:
CHECKED BY:
DRAWING SCALE: HYUNDAI OF CARMELOFFICE REMODEL4200 E 96th STREETCARMEL, INDIANAA u t o m o t i v e G r o u pN MEP Consulting Engineers262 Tradewinds DriveSanta Rosa BeachFlorida 32459317.506.8151dave@gnaengineering.comGOODERUM & ASSOCIATES ENGINEERINGP:E:874 Cheltenham DriveAvon IN, 46123South OfficeNorth Office07-09-2021JEFFREY M. PE
R
KEY07-09-2021
07-09-2021
2 SCALE: 1/8" = 1'-0"
HVAC AND PLUMBING PLAN
1. ROUTE 1/2" CW LINE FROM NEW CW LINE
SERVING NEW SINK TO ICE MAKER BOX.
2. ROUTE NEW 1-1/2" SANITARY LINE DOWN
FROM NEW SINK TO 1ST FLOOR INTERSTITIAL
SPACE. ROUTE NEW LINE WEST IN
INTERSTITIAL SPACE, THROUGH WIDE
FLANGE BEAM ABOVE REFRESHMENT AREA,
AND TO EXISTING SANITARY LINE 3" OR
LARGER BEHIND DRINKING FOUNTAIN. ROUTE
NEW 1-1/2" VENT LINE FROM NEW SINK TO
EXISTING VENT LINE 2" OR LARGER.
3. ROUTE NEW 1/2" CW AND 1/2" HW LINES TO
NEW SINK FROM RESTROOM AREA ON FIRST
FLOOR TO WHICH THE SANITARY LINE IS
ROUTED.
4. REMOVE SPIRAL DUCT BACK TO
RECTANGULAR DUCT SECTION.
5. TRANSITION FROM EXISTING DUCT TO NEW
DUCT WORK AT THIS POINT.
6. EXISTING S/A DUCT SERVING OFFICE NOT IN
CONTRACT IS EXISTING TO REMAIN.
7. CONNECT EXISTING DUCT TO NEW DUCT
WORK AND ADD MANUAL VOLUME DAMPER
AS SHOWN.
KEY NOTES:
1. REFERENCE SHEET MP001 FOR
ABBREVIATIONS, SYMBOLS, SPECIFICATIONS
AND SCHEDULES.
2. DEMOLITION PLANS ARE DIAGRAMMATIC AND
BASED ON LIMITED SURVEY DATA. HVAC
CONTRACTOR SHALL VISIT SITE, EXAMINE ALL
PLANS AND DETERMINE EXISTING ELEMENTS
TO REMAIN AND EXISTING TO BE REMOVED AS
NEEDED TO MEET DESIGN INTENT. HVAC
CONTRACTOR SHALL RECOVER ALL
REFRIGERANTS AND DISPOSE OF ALL HVAC
SYSTEMS PER EPA REQUIREMENTS. HVAC
CONTRACTOR SHALL MAP OUT EXISTING
DUCTWORK TO REMAIN, SEAL AND INSULATE
PER SPECIFICATIONS AND REMOVE ALL
UNUSED BRANCHES.
3. EXISTING HVAC UNIT WAS MANUFACTURED IN
2014. HVAC CONTRACTOR SHALL VERIFY
EXISTING UNIT IS FUNCTIONING PROPERLY,
CHANGE FILTERS, AND REPORT ALL
DEFICIENCIES TO G.C.
GENERAL NOTES:
#
1 SCALE: 1/8" = 1'-0"
HVAC DEMOLITION PLAN
3
4
5
2
6
7
SANITARY ISOMETRIC
SCALE: NONE C
SAN
SK
1-1/2"1-1/2" V2
2
1
KEY PLAN
SCALE: NONE
LAY-IN DIFFUSER DETAILA
SECURE FLEXIBLE DUCT TO
SUPPLY DIFFUSER ELBOW
FITTING WITH DRAWBANDS.
SHEET METAL ELBOW
SEAL ALL RIBS AND
CONNECTION TO
DIFFUSER NECK
SUPPLY DIFFUSER ACT CEILING
FLEX DUCT MAXIMUM LENGTH
SHALL NOT EXCEED 7'-0"
REFERENCE ARCHITECTURAL
REFLECTED CEILING PLAN AND
ELECTRICAL LIGHTING PLAN AND
COORDINATE INSTALLATION WITH ALL
CEILING ELEMENTS.
30° MAX
O
CONCENTRIC
TRANSITION MAX, 45
DEG. DIVERGING AND
60 DEG. CONVERGING
OFFSET. PROVIDE MINIMUM 2"
STRAIGHT SECTION AT EACH
END. MAX 30 DEG.
ECCENTRIC TRANSITION MAX,
30 DEG.
30° MAX
NOTE:
IN GENERAL, ELBOWS TO HAVE
FULL TURNING RADIUS (R=A).
WHERE "R" IS EQUAL TO OR
GREATER THAN "A" MINIMUM
RADIUS (R) = 4 INCHES.
R=A
A
DUCT CONSTRUCTION DETAILSB
45 DEG.
OCL CONNECTION
TAKE OFF. HAMMER
LOCKED OR FLANGED AND
FULLY SEALED
RECTANGULAR
DUCT
BRANCH
AIR FLOWV.D.
45 DEG. HIGH EFFICIENCY
TAKE OFF COMPLETELY
SEALED
ROUND SHEET METAL
DUCT TO DIFFUSER
118"
NOTE:
DOUBLE THICKNESS
TURNING VANES TO BE USED
WHERE NORMAL RADIUS
ELBOW IS IMPRACTICAL
& WHERE ELBOW IS WITHIN 5
FT OF A
BRANCH TAKE-OFF.AIR FLOWSCALE: NONE
SCALE: NONE