HomeMy WebLinkAboutNapleton Hyuandi - Electrical Plans - E100+42" +42" A:1 A:1 A:1 A:1 A:1 A:1 A:3 A:3 A:3 A:5 A:5 A:5 A:10 A:10 A:10 A:7 A:7 A:9 A:9 A:9 A:9 FLR FLR FLR FLR A:2 A:4 A:6 A:8 6 8 10 11 J K H J K H 6 8 10 11 J K H 6 8 10 11 L1 L1 L1L1L1 L1 L1 L1 L1 L1L1 L1 L1 L1 L1 L1 L1L1 L1 L1 L1L1 L1 L1L1 L1 L1 L1 L1 L1 L2 L2 EM EM OS OS OS OSOS OS EXC L2 L2 L2 EXC L2 L2 L2 L2 3 SCALE: 1/8" = 1'-0" ELECTRICAL POWER AND SYSTEMS PLAN E100 ELECTRICAL PLANS DRAWING ISSUE HISTORY BID / PERMIT ISSUE: CONSTRUCTION SET: COPYRIGHT 2021 210519 JP JP AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE: HYUNDAI OF CARMELOFFICE REMODEL4200 E 96th STREETCARMEL, INDIANAA u t o m o t i v e G r o u pN MEP Consulting Engineers262 Tradewinds DriveSanta Rosa BeachFlorida 32459317.506.8151dave@gnaengineering.comGOODERUM & ASSOCIATES ENGINEERINGP:E:874 Cheltenham DriveAvon IN, 46123South OfficeNorth Office07-09-2021JEFFREY M. PE R KEY07-09-2021 07-09-2021 1. REMOVE FIXTURE AND REUSE BRANCH CIRCUIT FOR FUTURE FIXTURE. 2. EXISTING FIXTURE TO REMAIN AND BE REUSED. 3. REMOVE FIXTURE AND REUSE BRANCH CIRCUIT FOR FUTURE LIGHT. TYPICAL. 4. CONNECT NEW LIGHT FIXTURES TO EXISTING LIGHTING BRANCH CIRCUIT. RECONFIGURE EXISTING BRANCH CIRCUITRY AS REQUIRED TO ACCOMMODATE NEW LIGHT FIXTURES AND CONTROL. 5. PROVIDE POKE THRU TWO-COMPARTMENT FLOOR BOX SIMILAR TO "HUBBELL SYSTEM ONE." FIELD COORDINATE EXACT LOCATION OF FLOOR BOX ROUGH-IN WITH LOCATION OF SYSTEM FURNITURE. 6. REPLACE EXISTING LIGHT FIXTURES IN THIS ROOM WITH NEW FIXTURES. KEY NOTES: 1. REFERENCE SHEET E001 FOR LEGENDS, ABBREVIATIONS, SPECIFICATIONS AND NOTES. 2. DEMOLITION PLANS ARE DIAGRAMMATIC AND BASED ON LIMITED SURVEY DATA. ELECTRICAL CONTRACTOR SHALL VISIT SITE, EXAMINE ALL PLANS AND DETERMINE EXISTING ELECTRICAL ELEMENTS TO REMAIN AND EXISTING TO BE REMOVED AS NEEDED TO MEET DESIGN INTENT. ELECTRICAL CONTRACTOR SHALL THEN WRING OUT CONDUCTORS AND REMOVE ITEMS MAINTAINING CONTINUITY ON CONDUCTORS TO REMAIN. E.C. SHALL DE-TERMINATE AND REMOVE OR CAP AND TAG ALL CONDUCTORS AND ASSOCIATED RACEWAYS TO BE ABANDON. PRIOR TO ANY DEMOLITION, E.C. SHALL MAKE SAFE ALL ENERGIZED ITEMS TO BE REMOVED. 3. BRANCH CIRCUIT NUMBERS SHOWN ARE FOR GROUPING PURPOSES ONLY. FIELD VERIFY ACTUAL CIRCUIT NUMBERS AND UPDATE AS-BUILTS ACCORDINGLY. 4. PROVIDE BRANCH CIRCUITRY FROM NEAREST 208Y/120V BRANCH CIRCUIT BREAKER PANEL IN AVAILABLE SPACE. INSTALL NEW 20/1P CIRCUIT BREAKERS AS REQUIRED TO ACCOMMODATE NEW CIRCUITRY. DO NOT EXCEED NEC ALLOWANCES FOR LOADING OF BRANCH CIRCUITS. 5. ALL EXIT SIGNS, EMERGENCY LIGHTING UNITS, AND NIGHT LIGHTS SHALL HAVE UNSWITCHED BRANCH CIRCUIT. CONNECT THE NEW LIGHT FIXTURES TO NEAREST AVAILABLE UNSWITCHED LIGHTING BRANCH CIRCUIT. 6. REFERENCE CBMC LIGHTING PLAN FOR EXACT FIXTURE LOCATIONS, SPECIFICATIONS, AND MORE INFORMATION. GENERAL NOTES:# 1 SCALE: 1/8" = 1'-0" ELECTRICAL DEMOLITION PLAN 2 SCALE: 1/8" = 1'-0" ELECTRICAL LIGHTING PLAN KEY PLAN SCALE: NONE 1 1 1 1 1 1 2 2 2 2 2 2 2 22 2 3 4 4 5 LIGHTING REVISION 1 1 07-12-2021 1 4 6 6 1 08/18/21