Loading...
HomeMy WebLinkAboutA400.0SCALE: 1 1/2" = 1'-0" 1 G100 WALL ASSEMBLY - TYPE 1 SCALE: 1 1/2" = 1'-0" 2 G100 WALL ASSEMBLY - TYPE 2 58" GYP. BOARD 5" HIGH DENSITY SPRAY FOAM INSULATION 2X4 STUDS @ 16" O.C. CONCRETE FOUNDATION WALL, THICKNESS VARIES FLUID APPLIED WATERPROOFING DRAINAGE BOARD VARIES 1 1/2" 5/8" VARIES 1 12" AIR SPACE TO FRAMING SCALE: 1 1/2" = 1'-0" 4 G100 WALL ASSEMBLY - TYPE 4 3 1/2" 8" CONCRETE WALL FLUID APPLIED WATERPROOFING DRAINAGE BOARD 8" SCALE: 1 1/2" = 1'-0" 5 G100 WALL ASSEMBLY - TYPE 5 8"8" 1 1/2"5/8"1'-1 5/8"3 1/2"SCALE: 1 1/2" = 1'-0" 6 G100 WALL ASSEMBLY - TYPE 6 SCALE: 1 1/2" = 1'-0" 7 G100 WALL ASSEMBLY - TYPE 7 5 8" GYP. BOARD 5" HIGH DENSITY SPRAY FOAM INSULATION 2X4 STUDS @ 16" O.C. 8" CMU WALL 7 5/8" 1 1/2" 5/8" 1'-6 7/8" 1 12" AIR SPACE 3 1/2" 5 8" GYP. BOARD 5" HIGH DENSITY SPRAY FOAM INSULATION 2X4 STUDS @ 16" O.C. 1 12" AIR SPACE 1 1/2" 5/8" 3 1/2" 7 5/8" 1 1/2" 1'-6 7/8"3 1/2"1 1/2" 3 1/2" SCALE: 1 1/2" = 1'-0" 8 G100 WALL ASSEMBLY - TYPE 8 5 8" GYP. BOARD 5" HIGH DENSITY SPRAY FOAM INSULATION 2X4 STUDS @ 16" O.C. 8" CMU WALL 5 5/8" 1 1/2" 5/8" 1'-4 7/8" 1 12" AIR SPACE 3 1/2" 5 8" GYP. BOARD 5" HIGH DENSITY SPRAY FOAM INSULATION 2X4 STUDS @ 16" O.C. 1 12" AIR SPACE 1 1/2" 5/8" 3 1/2" 5 5/8" 1 1/2" 1'-4 7/8"3 1/2"1 1/2" 3 1/2" 5/8"3 1/2" 1/2" 5 5/8" 3" 1" 3 5/8" 1'-5 7/8" SCALE: 1 1/2" = 1'-0" 9 G100 WALL ASSEMBLY - TYPE 9 MASONRY VENEER FLUID APPLIED WEATHER BARRIER 6" CMU WALL 1" AIR SPACE 58 " GYP. BOARD ROCKWOOL COMFORTBATT R-15 INSULATION 2X4 STUDS @ 16" O.C. 12" AIR SPACE 34" CAVCLEAR ADJUSTABLE MASONRY TIES @ 16" O.C. VERT. & 24" O.C. HORIZONTAL 5/8"5 1/2" 3" 1" 3 5/8" 1'-2 1/2" SCALE: 1 1/2" = 1'-0" 10 G100 WALL ASSEMBLY - TYPE 10 MASONRY VENEER 34" PLYWOOD 1" AIR SPACE 58" GYP. BOARD ROCKWOOL COMFORTBATT R-15 INSULATION 2X6 STUDS @ 16" O.C. 34" CAVCLEAR MASONRY VENEER 5/8"3 1/2"1/2" 5 5/8" 3" 1" 3 5/8" 1'-5 7/8"5/8"5 1/2"3" 1" 3 5/8" 1'-2 1/2"3/4"3/4" SCALE: 1 1/2" = 1'-0" 3 G100 WALL ASSEMBLY - TYPE 3 58" GYP. BOARD 5" HIGH DENSITY SPRAY FOAM INSULATION 2X4 STUDS @ 16" O.C. 8" CONCRETE WALL 1'-2" 1 1/2" 5/8" 1'-7 5/8" 1 12" AIR SPACE TO FRAMING 3 1/2"1'-2" 1 1/2"5/8"1'-7 5/8"3 1/2"SCALE: 1 1/2" = 1'-0" 12 G100 WALL ASSEMBLY - NOT USED 5/8"5 1/2" 3" 3/4" 3/4" 11 3/8" 34" PLYWOOD 58" GYP. BOARD ROCKWOOL COMFORTBATT R-15 INSULATION 2X6 STUDS @ 16" O.C. 34" FURRING STRIPS 5/8"5 1/2"3/4"3/4" 3" ROCKWOOL CAVITYROCK CONTINUOUS INSULATION FLUID APPLIED WEATHER BARRIER 3" ROCKWOOL CAVITYROCK CONTINUOUS INSULATION FLUID APPLIED WEATHER BARRIER 3" ROCKWOOL CAVITYROCK CONTINUOUS INSULATION WOOD VENEER SCALE: 1 1/2" = 1'-0" 11 G100 WALL ASSEMBLY - NOT USED 5/8"3 1/2" 1/2" 5 5/8" 3" 1" 3 5/8" 1'-5 7/8" MASONRY VENEER FLUID APPLIED WEATHER BARRIER 6" CMU WALL 1" AIR SPACE 58" SCHLUTER KERDI BOARD ROCKWOOL COMFORTBATT R-15 INSULATION 2X4 STUDS @ 16" O.C. 12" AIR SPACE 34" CAVCLEAR ADJUSTABLE MASONRY TIES @ 16" O.C. VERT. & 24" O.C. HORIZONTAL 5/8" 3 1/2"1/2"5 5/8" 3" 1" 3 5/8" 1'-5 7/8"3" ROCKWOOL CAVITYROCK CONTINUOUS INSULATION TILE - PER SCHEDULE GROUT - PER SCHEDULE THINSET 3" THERMAX SHEATHING - INTERIOR FOIL FACED INSULATION (R18.6) 5 8" GYP. BOARD 5" HIGH DENSITY SPRAY FOAM INSULATION 2X4 STUDS @ 16" O.C. 8" CONCRETE WALL VARIES 1 1/2" 5/8" VARIES 1 12" AIR SPACE TO FRAMING 3 1/2" 5 8" GYP. BOARD 5" HIGH DENSITY SPRAY FOAM INSULATION 2X4 STUDS @ 16" O.C. 1 12" AIR SPACE TO FRAMING 1 1/2" 5/8" 3 1/2" VARIES 1 1/2"VARIES3 1/2" 1 1/2" 3 1/2" 3" THERMAX SHEATHING - INTERIOR FOIL FACED INSULATION (R18.6) CONCRETE FOUNDATION WALL, THICKNESS VARIES FLUID APPLIED WATERPROOFING DRAINAGE BOARD VARIES 3" VARIES VARIES 3"VARIESVARIES 3" VARIES 3" THERMAX SHEATHING - INTERIOR FOIL FACED INSULATION (R18.6) 3" THERMAX SHEATHING - INTERIOR FOIL FACED INSULATION (R18.6) CONCRETE WALL, THICKNESS VARIES 3" VARIES 3"VARIES 3" McNICHOLAS ARCHITECTS OWNERSHIP AND USE OF DOCUMENTS DRAWINGS AND SPECIFICATIONS, AS INSTRUMENTS OF PROFESSIONAL SERVICE, ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT. THESE DOCUMENTS ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY PROJECT OR PURPOSE WHATSOEVER, WITHOUT THE PRIOR SPECIFIC WRITTEN AUTHORIZATION OF MGLM ARCHITECTS, LTD. FILE: C O P Y R I G H T 2 0 2 1 DRAWING #: DRAWING TITLE: DATE: SCALE: PROJECT #: NO. DATE ISSUE PROJECT NAME: Creek's End 4050 West 121st St. Zionsville, IN 46077 711 S. DEARBORN ST. SUITE 503 CHICAGO, ILLINOIS - 312.588.4109 - WWW.MGLMARCHITECTS.COM ---- 6/11/2021 ---- 7700-01 3/8" - 1'-0" WALL ASSEMBLIES G100 01 6/11/21 PERMIT SET 08/25/21