Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
4050 W 121st St ResCheck Compliance Certificate
Generated by REScheck-Web Software Compliance Certificate Project Creek's End Energy Code:2009 IECC Location:Zionsville, Indiana Construction Type:Single-family Project Type:New Construction Orientation:Bldg. faces 180 deg. from North Conditioned Floor Area:15,132 ft2 Glazing Area 7% Climate Zone:5 (5724 HDD) Permit Date: Construction Site: 4050 W 121st Street Zionsville, Indiana 46077 Owner/Agent: Charles Haywood 4100 W 121st Street Zionsville, Indiana 46077 Designer/Contractor: Matthew McNicholas McNicholas Architects | MGLM 711 South Dearborn Suite 503 Chicago, IL 60605 3125884109 matthew@mglmarchitects.com B-2021-00383Permit Number: Compliance: Passes using UA trade-off 9.4% Better Than Code Maximum UA:3288 Your UA:2980 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. U-Factor Req. U-Factor Prop. UA Req. UA Attic: Raised or Energy Truss 5,950 0.0 38.0 0.025 0.030 149 179 First Floor (Wood Studs): Wood Frame, 16" o.c. Orientation: Unspecified 6,118 0.0 13.0 0.057 0.057 349 349 Second Floor (Wood Studs): Wood Frame, 16" o.c. Orientation: Unspecified 5,862 0.0 13.0 0.057 0.057 334 334 First Floor (CMU): Masonry Block w/ Empty Cells Orientation: Unspecified 6,118 1.0 12.9 0.062 0.082 303 401 Type A: Solid Door (under 50% glazing) Orientation: Unspecified 48 0.280 0.350 14 17 Type C1: Solid Door (under 50% glazing) Orientation: Unspecified 43 0.280 0.350 12 15 Type C2: Solid Door (under 50% glazing) Orientation: Unspecified 43 0.280 0.350 12 15 Type H: Solid Door (under 50% glazing) Orientation: Unspecified 34 0.280 0.350 9 12 Type C3: Solid Door (under 50% glazing) Orientation: Unspecified 43 0.280 0.350 12 15 Type C4: Solid Door (under 50% glazing) Orientation: Unspecified 43 0.280 0.350 12 15 Project Title: Creek's End Data filename:Page 1 of 4 06/28/21Report date: Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. U-Factor Req. U-Factor Prop. UA Req. UA Type C5: Solid Door (under 50% glazing) Orientation: Unspecified 43 0.280 0.350 12 15 Type E: Solid Door (under 50% glazing) Orientation: Unspecified 28 0.280 0.350 8 10 Type B1: Glass Door (over 50% glazing) Orientation: Unspecified 33 0.280 0.350 9 12 Type B2: Glass Door (over 50% glazing) Orientation: Unspecified 33 0.280 0.350 9 12 Type B3: Glass Door (over 50% glazing) Orientation: Unspecified 33 0.280 0.350 9 12 Type B4: Glass Door (over 50% glazing) Orientation: Unspecified 33 0.280 0.350 9 12 Type B5: Glass Door (over 50% glazing) Orientation: Unspecified 33 0.280 0.350 9 12 Type B6: Glass Door (over 50% glazing) Orientation: Unspecified 33 0.280 0.350 9 12 Type B7: Glass Door (over 50% glazing) Orientation: Unspecified 33 0.280 0.350 9 12 Type B8: Glass Door (over 50% glazing) Orientation: Unspecified 33 0.280 0.350 9 12 Type D1: Glass Door (over 50% glazing) Orientation: Unspecified 44 0.280 0.350 12 15 Type D2: Glass Door (over 50% glazing) Orientation: Unspecified 44 0.280 0.350 12 15 Type D3: Glass Door (over 50% glazing) Orientation: Unspecified 44 0.280 0.350 12 15 Type G: Glass Door (over 50% glazing) Orientation: Unspecified 21 0.280 0.350 6 7 Window 1: Wood Frame Orientation: Unspecified 22 0.290 0.350 6 8 Type D: Wood Frame Orientation: Unspecified 38 0.290 0.350 11 13 Type E1: Wood Frame Orientation: Unspecified 16 0.290 0.350 5 5 Type E2: Wood Frame Orientation: Unspecified 16 0.290 0.350 5 5 Type E3: Wood Frame Orientation: Unspecified 16 0.290 0.350 5 5 Type E4: Wood Frame Orientation: Unspecified 16 0.290 0.350 5 5 Type E5: Wood Frame Orientation: Unspecified 16 0.290 0.350 5 5 Type F1: Wood Frame Orientation: Unspecified 4 0.290 0.350 1 1 Window 3: Wood Frame Orientation: Unspecified 4 0.290 0.350 1 1 Window 5: Wood Frame Orientation: Unspecified 22 0.290 0.350 6 8 Type G2: Wood Frame Orientation: Unspecified 22 0.290 0.350 6 8 Type H1: Wood Frame Orientation: Unspecified 9 0.290 0.350 3 3 Type H2: Wood Frame Orientation: Unspecified 9 0.290 0.350 3 3 Type I: Wood Frame Orientation: Unspecified 37 0.290 0.350 11 13 Type J: Wood Frame Orientation: Unspecified 38 0.290 0.350 11 13 Project Title: Creek's End Data filename:Page 2 of 4 06/28/21Report date: Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. U-Factor Req. U-Factor Prop. UA Req. UA Type K: Wood Frame Orientation: Unspecified 16 0.290 0.350 5 5 Type B: Wood Frame Orientation: Unspecified 2 0.290 0.350 1 1 Type A2: Wood Frame Orientation: Unspecified 14 0.290 0.350 4 5 Type A3: Wood Frame Orientation: Unspecified 14 0.290 0.350 4 5 Sunroom: Metal Frame w/ Thermal Break Orientation: Unspecified 159 0.280 0.350 45 56 Second Floor (CMU): Masonry Block w/ Empty Cells Orientation: Unspecified 5,862 1.0 12.9 0.062 0.082 316 418 Type D2: Wood Frame Orientation: Unspecified 38 0.290 0.350 11 13 Type E6: Wood Frame Orientation: Unspecified 16 0.290 0.350 5 5 Type E7: Wood Frame Orientation: Unspecified 16 0.290 0.350 5 5 Type E8: Wood Frame Orientation: Unspecified 16 0.290 0.350 5 5 Type F3: Wood Frame Orientation: Unspecified 4 0.290 0.350 1 1 Type F4: Wood Frame Orientation: Unspecified 4 0.290 0.350 1 1 Type L1: Wood Frame Orientation: Unspecified 17 0.290 0.350 5 6 Type L2: Wood Frame Orientation: Unspecified 17 0.290 0.350 5 6 Type L3: Wood Frame Orientation: Unspecified 17 0.290 0.350 5 6 Type L4: Wood Frame Orientation: Unspecified 17 0.290 0.350 5 6 Type L5: Wood Frame Orientation: Unspecified 17 0.290 0.350 5 6 Type L6: Wood Frame Orientation: Unspecified 17 0.290 0.350 5 6 Type L7: Wood Frame Orientation: Unspecified 17 0.290 0.350 5 6 Type L8: Wood Frame Orientation: Unspecified 17 0.290 0.350 5 6 Type K: Wood Frame Orientation: Unspecified 53 0.290 0.350 15 18 Type N2: Wood Frame Orientation: Unspecified 64 0.290 0.350 19 23 Type N1: Wood Frame Orientation: Unspecified 64 0.290 0.350 19 23 Type O1: Wood Frame Orientation: Unspecified 6 0.290 0.350 2 2 Type O2: Wood Frame Orientation: Unspecified 6 0.290 0.350 2 2 Type O3: Wood Frame Orientation: Unspecified 6 0.290 0.350 2 2 Type O4: Wood Frame Orientation: Unspecified 6 0.290 0.350 2 2 Type O5: Wood Frame Orientation: Unspecified 6 0.290 0.350 2 2 Type O6: Wood Frame Orientation: Unspecified 6 0.290 0.350 2 2 Project Title: Creek's End Data filename:Page 3 of 4 06/28/21Report date: Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. U-Factor Req. U-Factor Prop. UA Req. UA Type P1: Wood Frame Orientation: Unspecified 23 0.290 0.350 7 8 Type P2: Wood Frame Orientation: Unspecified 23 0.290 0.350 7 8 Type P3: Wood Frame Orientation: Unspecified 23 0.290 0.350 7 8 Type Q1: Wood Frame Orientation: Unspecified 47 0.290 0.350 14 16 Type Q2: Wood Frame Orientation: Unspecified 47 0.290 0.350 14 16 Type R: Wood Frame Orientation: Unspecified 8 0.290 0.350 2 3 Type S: Wood Frame Orientation: Unspecified 31 0.290 0.350 9 11 Type T1: Wood Frame Orientation: Unspecified 7 0.290 0.350 2 3 Type T2: Wood Frame Orientation: Unspecified 7 0.290 0.350 2 3 Type U: Wood Frame Orientation: Unspecified 19 0.290 0.350 5 7 Type A4: Wood Frame Orientation: Unspecified 14 0.290 0.350 4 5 Type A5: Wood Frame Orientation: Unspecified 14 0.290 0.350 4 5 Type A6: Wood Frame Orientation: Unspecified 14 0.290 0.350 4 5 Type A7: Wood Frame Orientation: Unspecified 14 0.290 0.350 4 5 Type A8: Wood Frame Orientation: Unspecified 14 0.290 0.350 4 5 Type A9: Wood Frame Orientation: Unspecified 14 0.290 0.350 4 5 Floor (Unheated): Slab-On-Grade (Unheated) Insulation depth: 0.7'573 15.0 0.923 0.767 529 439 Floor (Heated): Slab-On-Grade (Heated) Insulation depth: 0.7'216 15.0 0.923 0.767 199 165 Basement Wall: Solid Concrete or Masonry Orientation: Unspecified Wall height: 11.6' Depth below grade: 10.1' Insulation depth: 9.2' 3,807 0.0 19.0 0.041 0.059 156 224 Type A1: Wood Frame Orientation: Unspecified 14 0.290 0.350 4 5 Crawl Space A: Solid Concrete or Masonry Wall height: 5.5' Depth below grade: 4.0' Insulation depth: 4.1' 1,858 0.0 15.0 0.057 0.065 67 77 Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Title: Creek's End Data filename:Page 4 of 4 06/28/21Report date: Matthew McNicholas, AIA LEEP AP 06.28.21