Loading...
HomeMy WebLinkAboutS001.0 - HAM 30 Foundation SlabTHICKEN SLAB DW. SINK WATERSOFTNER(PER PLUMB)REF.THICKEN SLABTHICKEN SLAB7'-23 16" 6'-1011 16" 7'-23 16" 20'-9"18'-61 4"10'-7"23'-53 4" 2'-1112" 6'-0"11'-91 2" 21'-3" 94'-7"4'-112"4'-112"3'-8"3'-8"1'-4"2'-8" 7'-2" 2'-8"12'-6" 21'-5"1'-4"33'-11" 35'-3"27'-1112 " 4'-212"52'-5" 24'-212" 84'-7" 12'-0" 96'-7"13'-11"20'-0"4'-112"38'-012"1'-1112"16'-3"1'-912"1'-112"3'-10"1'-2"6'-0" 1'-2"612" 2'-9"612"1'-112"7"1112"1'-112" 9'-312" 912"912" 1112"1'-4" 2'-0"912"912"6'-112"5'-212" 6" 6"6"6'-7" 4'-8" 17'-10"912"912"712"71 2" 71 2"71 2" 91 2" 712"912"912"1'-0"71 2"10'-612"3'-0" 8'-1"NO ANCHORSTRAPSNO ANCHOR STRAPS NO ANCHORSTRAPS15'-1" 8'-7"512"20'-912" 20'-912" 4x4 STL. COL. on 24"x24"x12" footing 1'-812"1'-4"4"312"THICKEN SLABTHICKEN EDGE312" 312" 4" 5'-3" 3'-6"21'-2" 3'-5" 1'-4"7'-712"714" 1'-4"20'-3516"1'-4" THICKEN SLAB21'-212"1'-4" R-10 RIGID INSULATION R-10 RIGID INSULATION R-10 RIGID INSULATION R-10 RIGID INSULATION R-10 RIGID INSULATION R-10 RIGID INSULATION R-10 RIGID INSULATION R-10 RIGID INSULATION R-10 RIGID INSULATION UNEXCAVATED - 4" MIN. CONCRETE SLAB - GRAVEL FILL UNEXCAVATED - 4" MIN. CONCRETE SLAB - GRAVEL FILL RECESSED 8" VERIFY w/ ELEVATOR MANUFACTURER/ CONTRACTOR FOR SPECS. Make yourself at homeHamletLot 30-31 Hamlet LaGrange TownhouseGrosmont3SCALE: 1/4"=1'-0" FOUNDATION PLAN POURED AT PORCHES TO BE COMPLETION OF HOMEPOURED AT PORCHES TO BE COMPLETION OF HOME 12"x18" ANCHOR BOLTS 48" O.C. AIRSPACE BRICK VENEER FD5 FOUNDATION DETAIL7"534"12"X22" DEEP CONCRETE FOOTING @ 2500 PSI R-10 RIGID INSULATION 12"X22" DEEP CONCRETE FOOTING @ 2500 PSI 12"X22" DEEP CONCRETE FOOTING @ 2500 PSI 12"X22" DEEP CONCRETE FOOTING @ 2500 PSI 12"x18" ANCHOR BOLTS 48" O.C. HOUSE SLABHOUSE SLAB GARAGE SLAB TOP OF MAIN LEVEL SUB FLOOR 12" EDGE FD1 FOUNDATION DETAIL FD2 FOUNDATION DETAIL FD3 FOUNDATION DETAIL FD4 FOUNDATION DETAIL 312"X31 2"X14" STL. COLUMN w/ 3 4"x12"x12" BASE PL. w/ (4)34" HEADED ANCHOR ASTM A325 F1554 GRADE 36 SEE SCHEDULED FOR SIZE & REINFORCEMENT 3" CLEAR 3" CLEAR 3" CLEAR1'-0"1. FOUNDATION DETAIL LEGEND INTERIOR COLUMN FOOTING DETAIL FTG. SIZEN0. REINFORCEMENT INTERIOR COLUMN FOOTING SCHEDULE A 54"X54"X12" (5)#4's E.W. B 48"X48"X12" (4)#4's E.W. C 42"X42"X12" (4)#4's E.W. D 36"X36"X12" (3)#4's E.W. E 30"X30"X12" (3)#4's E.W. BASED ON A SAFE ALLOWABLE BEARING PRESSURE OF 2000 psf ( TO BE FIELD VERIFIED ) 20'-712"GAS w/RE-CIRCULATING PUMPTANKLESS W.H.21'-112"10'-41316" GAS LINE H.B.912"4x4 STL. COL. on 24"x24"x12" footing 2'-1" 2'-71 2" 6'-01 2"8'-014"29'-112" 2 STORY 4x4 STL. COL. 4x4 STL. COL. 4x4 STL. COL. 4x4 STL. COL. ON STEEL BEAM ABOVE W.D. EXHAUSTTO EXTERIOR MICRO LOCATION W.C.SHOWER HEAD DOUBLE OVEN H.B. GAS LINE H.B. REF. H.B. INDUCTION COOKTOP NO THRESHOLDBEV CENTER DBLE. WALL FLOATING VANITY DIVERTER VALVE HAND HELD HEAD MAIN VALVE 07.19.2021 FINAL PRINTS 07.19.2021 08/25/21