HomeMy WebLinkAboutLS100.0APPLICABLE CODES: ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING BUILDING CODE 2014 INDIANA BUILDING CODE (2012 IBC WITH STATE AMENDMENTS) STRUCTURAL CODE 2012 INDIANA BUILDING (2012 IBC, ASCE-7-2010) PLUMBING CODE 2012 INDIANA PLUMBING CODE MECHANICAL CODE 2014 INDIANA MECHANICAL CODE (2012 IMC WITH STATE AMENDMENTS) ELECTRICAL CODE 2009 INDIANA ELECTRICAL CODE (2008 NEC WITH AMENDMENTS) FIRE/LIFE SAFETY CODE 2014 INDIANA FIRE CODE (2012 IFC WITH STATE AMENDMENTS) ACCESSIBILITY CODE 2014 INDIANA BUILDING CODE, CH11-ACCESSIBILITY, ANSI A-117.1 STANDARD, ADA ACCESSIBILITY GUIDELINES - 2009 EDITION ENERGY CODE 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007) WITH INDIANA AMMENDMENTS GENERAL ADMINISTRATIVE RULES 2ND EDITION. CODE SUMMARY GENERAL NOTES APPLICABLE WHERE REQUIRED BY CODE: 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). 3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. PARALLEL DESIGN GROUP, IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. 6. REFER TO WALL TYPES SHEET FOR WALL TYPE AND CONSTRUCTION DETAILS. 7. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. APPLICABLE BUILDING CODES OCCUPANCY LOADS EXISTING ELECTRICAL PANEL LOCATION BUILDING EXIT LOCATION EMERGENCY LIGHTING NIGHT LIGHT/EMERGENCY LIGHTING; REFERENCE REFLECTED CEILING PLAN LEGEND EX EL NL EP ASSEMBLY OCCUPANCY REGION(S) STORAGE AREA REGION(S) FE EXIT SIGN RECESSED FIRE EXTINGUISHER OR SURFACE MOUNTED FIRE EXTINGUISHER AREA NOT IN CONTRACT AREA OF WORK COMMON PATH OF EGRESS EXIT ACCESS TRAVEL DISTANCE LOBBY 100 STORAGE 101 IT 102 CONFERENCE 103 CONFERENCE 104 OPEN OFFICE 105 COFFEE 106 PHONE 107 PHONE 108 PHONE 109 OFFICE 113 CONFERENCE 114 HUDDLE 115 ELEL COMMON PATH OF EGRESS DISTANCE = 24'EXIT ACCESS TRAVEL DISTANCE = 128'EXIT ACCESS TRAVEL DISTANCE = 165'EX EX EX WELLNESS 111 PHOTO/VIDEO 112 COPY 110 FEEL EL EL EP FE [PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502021.16204.15.21SFKBELEMENT THREEMIDTOWN EAST -1ST FLOOR571 MONON BLVD, CARMEL, INDIANA 46032A001 LIFE SAFETY PLAN CHANGE OF OCCUPANCY CLASS: No SPRINKLER SYSTEM (YES/NO): Yes TOTAL BUILDING SQ FT: 76,084 SF SCOPE OF WORK: OFFICE SPACE BUILD-OUT REMODEL OF PREVIOUSLY BUILT-OUT OFFICE FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS: No 3/32" = 1'-0" LIFE SAFETY PLAN1 OCCUPANCY: (B)USINESS EXIT TRAVEL DISTANCE (FEET): 300 NUMBER OF REQUIRED EXITS: 2 COMMON TRAVEL PATH OF EGRESS (FEET): 100 USABLE AREA: 5,657 SF TOTAL AREA ON FLOOR: 19,021 SF OCC KEY SPACE TYPE OCC CLASSIFICATION AREA SF PER OCCUPANT OCCUPANT LOAD (B)USINESS IBC Accessory storage areas, mechanical equipment room 183 SF 300 0.6 (B)USINESS CONFERENCE IBC Assembly without fixed seats - Unconcentrated (tables and chairs)1,079 SF 15 71.9 (B)USINESS IBC Business areas 4,395 SF 100 43.9 Total Project Area / Total Project Occupant Load 5,657 SF 116.5 REVISION SCHEDULEMARK DATE DESCRIPTION07/26/21