HomeMy WebLinkAboutLS100.0APPLICABLE CODES:
ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING
BUILDING CODE
2014 INDIANA BUILDING CODE (2012 IBC WITH STATE AMENDMENTS)
STRUCTURAL CODE
2012 INDIANA BUILDING (2012 IBC, ASCE-7-2010)
PLUMBING CODE
2012 INDIANA PLUMBING CODE
MECHANICAL CODE
2014 INDIANA MECHANICAL CODE (2012 IMC WITH STATE AMENDMENTS)
ELECTRICAL CODE
2009 INDIANA ELECTRICAL CODE (2008 NEC WITH AMENDMENTS)
FIRE/LIFE SAFETY CODE
2014 INDIANA FIRE CODE (2012 IFC WITH STATE AMENDMENTS)
ACCESSIBILITY CODE
2014 INDIANA BUILDING CODE, CH11-ACCESSIBILITY, ANSI A-117.1 STANDARD, ADA
ACCESSIBILITY GUIDELINES - 2009 EDITION
ENERGY CODE
2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007) WITH INDIANA
AMMENDMENTS GENERAL ADMINISTRATIVE RULES 2ND EDITION.
CODE SUMMARY
GENERAL NOTES
APPLICABLE WHERE REQUIRED BY CODE:
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED
PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE
REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE.
FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND
ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS
NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL
BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA).
3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A
COMPLETE, WORKING SYSTEM. PARALLEL DESIGN GROUP, IS NOT
RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION
OF THE FIRE SPRINKLER SYSTEM.
4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL
REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND
RELATED DOCUMENTS, WITH THE STATE AND LOCAL
AUTHORITIES HAVING JURISDICTION OVER THE PROJECT.
5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO
NFPA 10. COORDINATE WITH OWNER/LANDLORD ON
EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE
OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
6. REFER TO WALL TYPES SHEET FOR WALL TYPE AND
CONSTRUCTION DETAILS.
7. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM
NOTIFICATION APPLIANCES TO REMAIN.
APPLICABLE BUILDING CODES
OCCUPANCY LOADS
EXISTING ELECTRICAL PANEL LOCATION
BUILDING EXIT LOCATION
EMERGENCY LIGHTING
NIGHT LIGHT/EMERGENCY LIGHTING;
REFERENCE REFLECTED CEILING PLAN
LEGEND
EX
EL
NL
EP
ASSEMBLY OCCUPANCY REGION(S)
STORAGE AREA REGION(S)
FE
EXIT SIGN
RECESSED FIRE EXTINGUISHER OR
SURFACE MOUNTED FIRE EXTINGUISHER
AREA NOT IN CONTRACT
AREA OF WORK
COMMON PATH OF EGRESS
EXIT ACCESS TRAVEL DISTANCE
LOBBY
100
STORAGE
101
IT
102
CONFERENCE
103
CONFERENCE
104
OPEN OFFICE
105
COFFEE
106
PHONE
107
PHONE
108
PHONE
109
OFFICE
113 CONFERENCE
114
HUDDLE
115 ELEL COMMON PATH OF
EGRESS DISTANCE = 24'EXIT ACCESS TRAVEL DISTANCE = 128'EXIT ACCESS TRAVEL DISTANCE = 165'EX
EX
EX
WELLNESS
111 PHOTO/VIDEO
112
COPY
110
FEEL
EL EL EP
FE [PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502021.16204.15.21SFKBELEMENT THREEMIDTOWN EAST -1ST FLOOR571 MONON BLVD, CARMEL, INDIANA 46032A001
LIFE SAFETY PLAN
CHANGE OF OCCUPANCY CLASS:
No
SPRINKLER SYSTEM (YES/NO):
Yes
TOTAL BUILDING SQ FT:
76,084 SF
SCOPE OF WORK:
OFFICE SPACE BUILD-OUT REMODEL OF PREVIOUSLY BUILT-OUT OFFICE
FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS:
No
3/32" = 1'-0"
LIFE SAFETY PLAN1
OCCUPANCY:
(B)USINESS
EXIT TRAVEL DISTANCE (FEET):
300
NUMBER OF REQUIRED EXITS:
2
COMMON TRAVEL PATH OF EGRESS (FEET):
100
USABLE AREA:
5,657 SF
TOTAL AREA ON FLOOR:
19,021 SF
OCC KEY SPACE TYPE OCC CLASSIFICATION AREA SF PER
OCCUPANT
OCCUPANT
LOAD
(B)USINESS IBC Accessory storage areas, mechanical
equipment room 183 SF 300 0.6
(B)USINESS CONFERENCE IBC Assembly without fixed seats -
Unconcentrated (tables and chairs)1,079 SF 15 71.9
(B)USINESS IBC Business areas 4,395 SF 100 43.9
Total Project Area / Total Project Occupant Load 5,657 SF 116.5 REVISION SCHEDULEMARK DATE DESCRIPTION07/26/21