HomeMy WebLinkAboutS101.01. WHERE INDICATED, REMOVE WALL CONSTRUCTION IN ITS ENTIRETY. PRIOR TO DEMOLITION, CAREFULLY INVESTIGATE CONCEALED CONDITIONS TO VERIFY THERE IS NO ACTIVE INFRASTRUCTURE. 2. UNLESS NOTED OTHERWISE, EXISTING CEILING GRID, TILE HVAC DIFFUSERS AND RETURNS TO REMAIN. 3. ALL ELECTRICAL SHOWN ON THIS SHEET IS TO BE REMOVED; PATCH WALLS AND FLOOR AS REQUIRED AND PREP TO RECEIVE NEW FINISHES. SEE ELECTRICAL PLAN FOR EXISTING POWER AN DATA TO REMAIN. 4. UNLESS NOTED OTHERWISE, EXISTING FINISHES TO REMAIN. SEE FINISH PLAN FOR FINAL FINISH SELECTIONS AND LOCATIONS. 5. REFERENCE THE COVER SHEET FOR ADDITIONAL DEMOLITION NOTES. 6. PATCH AND PREP WALLS WHERE DEMOLITION OCCURS ADJACENT AN EXISTING WALL. TERMINATE PLUMBING AT THE NEAREST LOCATION. GENERAL NOTESLEGEND SOLID LINES INDICATE EXISTING ITEMS TO REMAIN KEYED NOTES DASHED LINES AND SYMBOLS INDICATE EXISTING ITEMS TO BE REMOVED OR SALVAGED AREA NOT IN CONTRACT AREA OF WORK 1 8 2 3 4 5 5 6 7 7 7 1 9 10 [PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502021.16204.15.21SFKBELEMENT THREEMIDTOWN EAST -1ST FLOOR571 MONON BLVD, CARMEL, INDIANA 46032D101 DEMOLITION PLAN 1 EXISTING CASEWORK (INCLUDING FINISHES) TO REMAIN; CLEAN AND REPAIR AS REQUIRED. 2 REMOVE EXISTING WALL MOUNTED SIGNAGE AT THIS LOCATION. PATCH AND REPAIR WALL AS REQUIRED. 3 EXISTING WOOD PLATFORM (INCLUDING RAILING ON LEFT SIDE) TO REMAIN. CLEAN AND REPAIR AS REQUIRED. 4 REMOVE EXISTING BLACK METAL RAILING AT THIS LOCATION. PATCH WALL/FLOOR AS REQUIRED AND PREP TO RECEIVE NEW FINISHES. 5 REMOVE LINEAR LIGHT FIXTURE IN THIS AREA. SEE REFLECTED CEILING PLAN FOR MORE INFORMATION. 6 REMOVE EXISTING CEILING GRID, TILE, LIGHT FIXTURES AND HVAC DIFFUSERS IN THIS ROOM. AREA IS TO BE EXPOSED TO DECK; REMOVE ALL UNUSED WIRES AND EQUIPMENT. SEE REFLECTED CEILING PLAN FOR MORE INFORMATION. 7 REMOVE EXISTING FLOORING IN THIS ROOM OR AREA. SEE FINISH PLAN FOR MORE INFORMATION. 8 REMOVE EXISTING CASEWORK. 9 REMOVE ENTIRE EXISTING BACKSPLASH AND PREP WALL TO RECEIVE NEW IN THE SAME LOCATION. SEE FINISH PLAN FOR MORE INFORMATION. 10 REMOVE EXISTING DRYWALL BULKHEAD AND PORTION OF RECESSED LINEAR LIGHT IN THIS AREA. SEE REFLECTED CEILING PLAN FOR MORE INFORMATION. 1/8" = 1'-0" DEMOLITION PLAN1 REVISION SCHEDULEMARK DATE DESCRIPTION07/26/21